Sie sind auf Seite 1von 1

One Za'abeel | 4597‐AAB‐SC‐01

A. Structural Design Criteria.xmcd
Section Page 2 of 5 
Design and Engineering Dept.
______________________________________________________________________________________________________________________________

Part 2 -  Serviceability Requirements
Vertical Façade Types and Similar Structures

Element Loading Type Condition Limit Reference Remarks


AS 1288 / 
Short Duration  Shorter length of panel is in 
Glazing 4‐Edge Supported Lu/60 Appendix 
Out‐of‐Plane consideration
CW (Inhabit) 
AS 1288 / 
Short Duration  Unsupported length measured 
Glazing 2‐Edge Supported Lu/60 Appendix 
Out‐of‐Plane from support to support
CW (Inhabit) 
AS 1288 / 
Short Duration  Height of panel is in 
Glazing 1 Edge Supported h/30  Appendix 
Out‐of‐Plane consideration
CW (Inhabit) 
Brittle  Short Duration  Appendix  Shorter length of panel is in 
4‐Edge Supported Lu/360
Panels Out‐of‐Plane CW (Inhabit) consideration
Unsupported length measured 
Flexible  Short Duration  Appendix 
4‐Edge Supported Lu/60  from support to support ; For 
Panels Out‐of‐Plane CW (Inhabit)
wall cladding panel or ACP
Unsupported length measured 
Flexible  Short Duration  Appendix 
2‐Edge Supported Lu/60  from support to support ; For 
Panels Out‐of‐Plane CW (Inhabit)
wall cladding panel or ACP
Vertical and  Unsupported length measured 
Short Duration  Appendix 
Horizontal  2‐End Supported Lu/200  from support to support 
Out‐of‐Plane CW (Inhabit)
Members (General)
Vertical and  Unsupported length measured  
Short Duration  Appendix 
Horizontal  2‐End Supported Lu/180 from member to member and 
Out‐of‐Plane CW (Inhabit)
Members for single glazing (Monolithic)
Vertical and  Unsupported length measured  
Short Duration  Appendix 
Horizontal  2‐End Supported Lu/200  from member to member and 
Out‐of‐Plane CW (Inhabit)
Members for double glazing (IGU)
Vertical and  Unsupported length measured  
Short Duration  Appendix 
Horizontal  2‐End Supported Lu/90  from support to support and for 
Out‐of‐Plane CW (Inhabit)
Members flexible panels
Vertical and  Unsupported length measured  
Short Duration  Appendix 
Horizontal  2‐End Supported Lu/360 from support to support and for 
Out‐of‐Plane CW (Inhabit)
Members brittle panels 
Vertical and 
Short Duration  1 End Supported  Appendix  * Denominator varries with 
Horizontal  *2Lu
Out‐of‐Plane (Cantilever) CW (Inhabit) element type
Members
Unsupported length measured 
Horizontal  Long Duration In‐ Appendix 
2‐End Supported Lu/360 from support to support (Non‐
Members Plane CW (Inhabit)
trafficable)
Unsupported length measured 
Horizontal  Long Duration In‐ Appendix 
2‐End Supported Lu/1000 from support to support 
Members Plane CW (Inhabit)
(Trafficable)

Notes:
Short Duration Load includes but is not limited to wind loads, live loads
Long Duration Load includes but is not limited to selfweight, superimposed permanent loads
Brittle Panels includes but is not limited to stones
Flexible Panels includes but is not limited to metal panels
Vertical and Horizontal Members are independent of material type as long as they are considered as façade elements
Vertical Façade Types and Similar Structures includes but is not limited to storefronts, vestibules, continous curtain walls, balust

Legend
Lu ‐ Uns upported Length
h ‐ hei ght of a  pa nel
9 of 72
TempVer20.0_012018 | Engineer: S.M.LomboyJr.