ii. Analysis and Design Verifica on


A} Connec on on Typical Mullion
a} Analysis

⌂ This subsec on sets the input forces for the connec on under inves ga on.

Figure 1. Details and Design Parameters Figure 2. Member Local Axes

F1 := max( 0 , 0) ⋅ kN = 0.00⋅ kN ← Force Along X Axis Note: All set of forces from all load combina ons
are checked in this design sheet. However,
F2 := max( 0 , 0.399) ⋅ kN = 0.40⋅ kN ← Force Along Y Axis only the most cri cal with the over-all most
onerous effect is presented! For cross
F3 := max( 11.484 , 6.216) ⋅ kN = 11.48⋅ kN ← Force Along Z Axis checking refer to so ware's file.

M1 := max( 0 , 0) ⋅ kN⋅ m = 0.00⋅ kN⋅ m ← Moment About X Axis

M2 := max( 0 , 0.773) ⋅ kN⋅ m = 0.77⋅ kN⋅ m ← Moment About Y Axis

M3 := max( 0 , 0) ⋅ kN⋅ m = 0.00⋅ kN⋅ m ← Moment About Z Axis

Adjus ng the forces and moments to account for the local axis of the fastener and/or weld group:

( F1 F2 F3 M1 M2 M3 ) := ( F3 F2 F1 M3 M2 M1 )

25 of 72
TempVer20.0_012018 | Engineer: D. Dumapit | Checked: S.M. Lomboy Jr.