Sie sind auf Seite 1von 1

B

PLOT COORDINATES
AREA STATEMENT :
PLOT AREA 17428.00 m2 EAST NORTH

PLOT BOUNDARY LINE SITE PLAN KEY FACTORY GROUND FLOOR A 218147.140 376560.186
PLOT BOUNDARY LINE
40x40 mm 0.30 8 20 C/C PRODUCTION AREA 6483.00 m2
8 20 C/C B 218293.039 376654.038
OUTER 0.20 0.20 COPING WITH
Y4 AT 10
COPING WITH
OPC-30 Y4 AT 10 OPC-30 POLE LIGHT
STAFF REFRESHMENT AREA 157.70 m2

0.20
GROOVE IN PLASTER

NE
(TYP.) C 218348.127 376570.572

I
+0.15 0.02

GH
UTILITY AREA (FACTORY) 532.10 m2

BOU
GREEN AREA

10
1.00
1.00
0.30 D 218200.881 376475.853

0.25

R
INSIDE OUTSIDE 12 mm THK. CEMENT OFFICE BLOCK 302.00 m2

0
COLUMN PLASTAR 1:4 UR

.01
O
0.30 x 0.20 0.12 COLUMN 12 mm THK. CEMENT UTILITY AREA 348.00 m2 HB
BLOCK WORK PLASTAR 1:4 NE
IG
0.30 x 0.30 INTERLOCK

0.04

2.00

2.00
2.00

2.00
.48

2.00
0.10
±±0.00 SKY LIGHT GARDEN 275.00 m2
25x25 mm PLOT SIDE NEIGHBOUR SIDE PLOT SIDE NEIGHBOUR SIDE 3
40x40 mm INTERMEDIATE PRECAST WALL 17
OUTER PANEL 600X600 MANHOLE WITH HD GUARD ROOM 1&2 (15.60x2) 31.20 m2

0.60

0.80
-0.02
HOLLOW BLOCK MASONARY
2.5 x 2.5 CHAMFER COVER

1.00
±±0.00 200 x 300 COLUMNS IN CEMENT MORTAR
AT 3.60 m c/c

0.10
±±0.00
FIRST FLOOR A

0.200.30
0.20
F.G.L. F.G.L. F.G.L. F.G.L. F.G.L.
1.80MØ SOAK AWAY 9119

0.10
UTILITY AREA (FACTORY) 689.80 m2
2 COATS OF EPOXY 0.60 (Min.) or 0.60 (Min.) or
81050521
BITUMINUS PAINT UPTO HARD STARTA UPTO HARD STARTA 0.30x0.30 GUTTER WITH OFFICE BLOCK 65±0.00 m2 C
17428.00 Sqm

0.60
3.30 STRIP BEAM G.I GRATING

0.20

0.20
STRIP BEAM
3.60 SRC 30 CABRO SRC 30 CABRO
+0.15 3.30 +0.15 Y4 AT 12
+0.15 +0.15 12 OT 150 C/C 12 OT 150 C/C
ROAD SIDE BOUNDARY WALL ELEVATION SECOND FLOOR

0.30
3.60 8  AT 200 C/C 75 mm THK. 0.80 75 mm THK. 0.80
0.90 BLINDING CONC. 0.90 10 OTBINDERS - 5 NOS. BLINDING CONC. 0.90 10 OTBINDERS - 5 NOS.
SRC 20 SRC 20
NEIGHBOUR SIDE BOUNDARY WALL ELEVATION SCALE 1: 25 0.20 1.10
SECTION AT C-C
UTILITY AREA (FACTORY) 689.80 m2
SCALE 1: 25 COLUMN SECTION AT A-A SECTION AT B-B SCALE 1: 25 OFFICE BLOCK 65±0.00 m2
.08
SECTION AT X-X SCALE 1:25 SCALE 1: 25
1 75

10
3.28 SCALE 1: 25

±0
NOTE UR
N

40
2.00
TOTAL COVERED AREA 8129.00 m2 O

m
SEALANT NOTE

.00
BOUNDARY WALL 1. PRECAST COLUMNS & FOOTINGS - SELF FINISHED CONCRETE WITH GRAY CEMENT HB

RO

5m
FILLING (TYP.) WITH GABBRO AGGREGATES. IG
0.02 1. CONCRETE SURFACE BELOW G.L. WILL HAVE TWO COATS OF NE

AD
TOTAL BUILTUP AREA 10808.60 m2

SE
2.00 2. PRECAST PANELS - SELF FINISHED CONCRETE WITH WHITE CEMENT. EPOXY BASED BITUMINOUS PAINT BEFORE BACK FILLING.

TB
0.10 0.10 2% 2%
WITH LIMESTONE AGGREGATES. 2. ALL CONCRETE SURFACE ABOVE G.L. WILL HAVE TWO COATS OF
0.90

0.12
0.30

0.30
0.12
1.10 0.50 0.20

AC
CLEAR PROTECTIVE COATING. % OF COVERED AREA 46.65%

K
0.04
3. REINFORCEMENT FOR WALL PANELS WITH WELDED MESH A232 3. COLUMNS WILL HAVE 20Ø PVC ELECTRICAL CONDUITS.

0.130
0.200
TYPICAL STEEL PRECAST WALL PANEL 90x35x10cm HYDRAULIC PRESSED 1000 GUAGE POLYTHENE SHEET INTER LOCK ALL REINFORCEMENT WILL BE IN EPOXY COATED STEEEL ONLY. 4. ALL CORNERS EDGES WILL BE CHAMFERED FOR 2.5x2.5 CM. F.A.R. 0.620
CONC.KERB STONE

+0.15
0.30 3.30 0.30 SWEET SOIL CL 4. CONCRETE SURFACE BELOW G.L. WILL HAVE TWO COATS OF 5. ALL STRUCTURE BELOW PLINTH LEVEL (i.e. +0.15 m ABOVE G.L.) WILL HAVE
ASPHALT ROAD F.G.L. WEARING COURSE
ASPHALT CONCRETE EPOXY BASED BITUMINOUS PAINT BEFORE ERECTION. TWO COATS OF EPOXY BASED BITUMINOUS PAINT.
0.80 ROAD BASE ASPHALT
CONCRETE B.C. TYPE-1
5. ALL CONCRETE SURFACE ABOVE G.L. WILL HAVE TWO COATS OF 6. CEMENT BASED PAINT OF APPROVED QUALITY WITH ONE COAT OF PRIMER
SUB BASE AND TWO COATS OF CEMENT BASED PAINTS ON BOUNDARY WALL.
BOUNDARY WALL PLAN CLEAR PROTECTIVE COATING.
(GRANULAR MATERIAL)
SUB GRADE CBR AT 95% 7. 25 mm THICK EXPANSION JOINT @ 28.80 m c/c ie. FOR EVERY 8 BAYS. MAXIMUM HEIGHT OF FACTORY 15.00 M.
(MDD)
6. COLUMNS WILL HAVE 20Ø PVC ELECTRICAL CONDUITS. WITH FLEXEL BOARD AND JOINT SEALENT.
SCALE 1: 25
ROAD CROSS SECTION 7. ALL CORNERS EDGES WILL BE CHAMFERED FOR 2.5x2.5 CM.
8. ALL STRUCTURE BELOW PLINTH LEVEL (i.e. +0.15 m ABOVE G.L.) WILL HAVE
D
TWO COATS OF EPOXY BASED BITUMINOUS PAINT. EXTERNAL PAINTS
SECTION -1 9. GRILL WILL BE FABRICATED FROM GALVANISED STEEL SECTION WITH BOUNDARY WALLS
SCALE 1:25 40 x40 mm OUTER & 25x25 mm INTERMEDIATE SECTIONS AND TO BE COLUMNS : SELF FINISHED CONCRETE WITH GREY CEMENT ROOF RAL 3014
PAINTED IN BLACK ENAMEL PAINT.
PANELS : SELF FINISHED CONCRETE WITH WHITE CEMENT WALL RAL 3015
LOCATION PLAN
2 1 : 1000 B
A 173.08
NEIGHBOUR

2.00
10.10

UNDERGROUND FIRE WATER STORAGE


MH

7.94

4.00
+0.15 ±0.00
PUMP ROOM

TANK
4.20 x 5.20

1.94
MH
UP

SUBSTATION ROOF
±0.00
+4.25 00
7.
21.70

+4.65
23.97
25.50

7.02
PLATFORM

0.40

9.40

Q.TEL. BOX
50.00

PRE ENGINEERED
RIDGE VENTILATION
WITH G.I. GRATING
0.30x0.30 GUTTER

42.05
+14.50 +15.00 +14.50
±0.00
7.50

FACTORY ROOF
FACTORY 1

G.ROOM ROOF ±0.00


3.00

1.00x3.00m. SINGLE SKIN


+3.50 +3.20 SKYLIGHT (TYPICAL)
+0.15
5.20 +0.15

±0.00
13.50
6.00 6.00 1.50 101.30
02 01-01-2018 ISSUED FOR DC-1 APPROVAL

01 16-05-2017 ISSUED FOR DC-1 APPROVAL

00 23-04-2017 ISSUED FOR DC-1 APPROVAL

REV. DATE DESCRIPTION BY

NEIGHBOUR
100.01
100.00

SOAK AWAY +12.45 QR-Code MUNICIPALITY STAMP

0.02
SKYLIGHT

+12.60 7.51
1.51 4.00 2.00
70.22

+12.60
42.40

G+2 OFFICE ROOF

+11.10
59.50

±0.00

Enquiry No. : Application No :


±0.00
CONSULTANT REG. No : 5 GRADE : A CONSULTANT REG. No : GRADE :

PRE ENGINEERED CONSULTANT STAMP & SIGNATURE : SUB-CONSULTANT STAMP & SIGNATURE :
RIDGE VENTILATION

FACTORY 2

42.05
+14.50 +15.00 +14.50
+0.15

FACTORY ROOF
50.01

+12.30
TECHNICAL MANAGER : TARIK A MAHMOUD TECHNICAL MANAGER

1.00x3.00m. SINGLE SKIN REGISTRATION No. : 354 REGISTRATION No :


SKYLIGHT (TYPICAL)

+0.15

7.88 Tel : 44655586 Fax : 44655589 - P.O.BOX 39032, DOHA - QATAR


e-mail : info@alsaddconsult.com
5.20
PROJECT

+3.50

7.
00
3.00

G.ROOM ROOF
D CLAD FACTORY
18.56

+3.20

LOCATION:
NEW INDUSTRIAL AREA

1.83
WITH G.I. GRATING
0.30x0.30 GUTTER

±0.00
±0.00 CLIENT:
D CLAD
8.67

±0.00

4.11
7.94
7.50

DATE: JOB NO.:


APRIL-2017 P-078-17

2.00
TITLE:

SITE PLAN
175.08 C
D
NEIGHBOUR DRAWING NO.: SCALE:
A-01 As indicated
DRAWN BY: DESIGNED BY: CHECKED BY:
SITE PLAN SHAHOOD TARIK A MAHMOUD TARIK A MAHMOUD
1
N

1 : 200
CAD FILE: REGISTRATION No. : REGISTRATION No. :

354 354
REVISION SIGNATURE SIGNATURE

02

Das könnte Ihnen auch gefallen