Beruflich Dokumente
Kultur Dokumente
ALPHA
TOC
Return to
SECTION
TOC
OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are
governed by the provisions stated in the detailed “Offer of Sale” elsewhere in this document or available at www.parker.com/hydraulicvalve.
SAFETY GUIDE
For safety information, see Safety Guide SG HY14-1000 at www.parker.com/safety or call 1-800-CParker.
Sandwich Valves B
intro-index.indd dd
intro-index.indd dd
intro-index.indd dd
A
Series D1V.................................................................... Solenoid Operated....................................................................................A17 - A28
Accessories.....................................................................................................................................................................................A29 - A30
Series D1VA and D1VP................................................. Air and Oil Pilot Operated.........................................................................A31 - A34
Series D1VC, D1VD and D1VG.................................... Cam and Cam Lever Operated.................................................................A35 - A36
Series D1VL.................................................................. Lever Operated.........................................................................................A37 - A38
Installation..................................................................... Series D1V................................................................................................A39 - A40
Series D1SE (NFPA D03/CETOP 3, NG6 Mounting)
Series D1SE.................................................................. Solenoid Operated....................................................................................A41 - A43
Series D3 (NFPA D05/CETOP 5, NG10 Mounting)
Introduction and Technical Information............................................................................................................................................A44 - A51
Series D3W................................................................... Solenoid Operated....................................................................................A53 - A61
Accesories................................................................................................................................................................................................ A62.
Series D3DW................................................................. Solenoid Operated....................................................................................A63 - A67
Series D3A.................................................................... Air Operated.............................................................................................A68 - A70
Series D3C and D3D..................................................... Cam Operated..........................................................................................A71 - A72
Series D3L..................................................................... Lever Operated.........................................................................................A73 - A74
Installation..................................................................... Series D3..................................................................................................A75 - A76
Series D31 (NFPA D05H/CETOP 5H, NG10 Mounting)
Introduction and Technical Information .................................................................................................................................................... A78
Series D31..................................................................... Pilot Operated, Solenoid Controlled.........................................................A79 - A91
Accessories.............................................................................................................................................................................................. A92
Series D31NW............................................................... Pilot Operated, Solenoid Controlled......................................................A93 - A100
Accessories............................................................................................................................................................................................ A101
Series D31*A................................................................. Air Pilot Operated.................................................................................A102 - A103
Series D31*L................................................................. Lever Operated.....................................................................................A104 - A105
Series D3P.................................................................... Oil Pilot Operated.................................................................................A106 - A107
Installation..................................................................... Series D31, D3P...................................................................................A108 - A112
Series D41 (NFPA D07/CETOP 7, NG16 Mounting)
Introduction and Technical Information................................................................................................................................................... A114
Series D41VW............................................................... Pilot Operated, Solenoid Controlled.....................................................A115 - A122
Accessories............................................................................................................................................................................................ A123
Series D4L..................................................................... Lever Operated.....................................................................................A124 - A127
Series D4P.................................................................... Oil Pilot Operated.................................................................................A128 - A131
Installation..................................................................... Series D4..............................................................................................A133 - A135
Series D61 (NFPA D08/CETOP 8, NG25 Mounting)
Introduction and Technical Information................................................................................................................................................... A136
Series D61V.................................................................. Pilot Operated, Solenoid Controlled.....................................................A137 - A147
Accessories............................................................................................................................................................................................ A148
Series D61VA................................................................ Air Pilot Operated.................................................................................A149 - A150
Series D61VL................................................................ Lever Operated.....................................................................................A151 - A152
Series D6P.................................................................... Oil Pilot Operated.................................................................................A153 - A154
Installation..................................................................... Series D61, D6P...................................................................................A155 - A158
Series D81 (NFPA D08/CETOP 8, NG25 Mounting)
Introduction and Technical Information................................................................................................................................................... A160
Series D81V.................................................................. Pilot Operated, Solenoid Controlled.....................................................A161 - A171
Accessories............................................................................................................................................................................................ A172
Series D81VA................................................................ Air Pilot Operated.................................................................................A173 - A174
Series D81VL................................................................ Lever Operated.....................................................................................A175 - A176
Series D8P.................................................................... Oil Pilot Operated.................................................................................A177 - A178
Installation..................................................................... Series D81, D8P...................................................................................A179 - A182
Series D9L..................................................................... Lever Operated.....................................................................................A183 - A186
Series D101 (NFPA D10/CETOP 10, NG32 Mounting)
Introduction and Technical Information................................................................................................................................................... A188
Series D101V................................................................ Pilot Operated, Solenoid Controlled.....................................................A189 - A199
Accessories............................................................................................................................................................................................ A200
Series D101VA.............................................................. Air Pilot Operated.................................................................................A201 - A202
Series D101VL.............................................................. Lever Operated.....................................................................................A203 - A204
Series D10P.................................................................. Oil Pilot Operated.................................................................................A205 - A206
Installation..................................................................... Series D101, D10P...............................................................................A207 - A210
Series D111 (NFPA D10/CETOP 10, NG32 Mounting)
Series D111VW............................................................. Pilot Operated, Solenoid Controlled.....................................................A211 - A219
Installation...................................................................................................................................................................................A220 - A222
Series D4S (NG10, NG25, NG32)
Series D4S.................................................................... Directional Seat Valve...........................................................................A223 - A232
Series D5S (SAE Flange)
Series D5S.................................................................... Directional Seat Valve, SAE Flange......................................................A233 - A247
D1.indd, dd
D1.indd, dd
D1.indd, dd
D1.indd, dd
D1.indd, dd
A
Maximum Flow, LPM (GPM)
350 Bar (5000 PSI) w/o Malfunction
High Watt Low Watt Low Watt
Model Spool Symbol DC AC DC
A B
D1V*001 78 (20) 49 (13) 37 (10)
P T
A B
D1V*002 78 (20) 45 (12) 68 (18)
P T
A B
D1V*003 70 (18) 30 (8) 34 (9)
P T
A B
D1V*004 37 (10) 30 (8) 68 (18)
P T
A B
D1V*005 60 (16) 45 (12) 45 (12)
P T
A B
D1V*006 79 (21) 49 (13) 52 (14)
P T
A B
D1V*007 45 (12) 18 (5) 18 (5)
P T
A B
D1V*008 49 (13) 45 (12) 37 (10)
P T
A B
D1V*009 58 (15) 45 (12) 45 (12)
P T
A B
D1V*010 13 (4) 11 (3) 15 (4)
P T
A B
D1V*011 58 (16) 30 (8) 37 (10)
P T
A B
D1V*014 45 (12) 18 (5) 18 (5)
P T
A B
D1V*015 79 (21) 30 (8) 34 (9)
P T
A B
D1V*016 60 (16) 45 (12) 52 (14)
P T
A B
D1V*020 78 (20) 45 (12) 75 (20)
P T
A B
D1.indd, dd
A
Maximum Flow, LPM (GPM) Maximum Flow, LPM (GPM)
350 Bar (5000 PSI) 350 Bar (5000 PSI)
Model Spool Symbol w/o Malfunction Model Spool Symbol w/o Malfunction
A B A B
D1V*1 83 (22) D1V*20 # 53 (14)
P T P T
A B A B
D1V*2 83 (22) D1V*26 # 11 (3)
P T P T
A B A B
D1V*4 45 (12) D1V*30 # 19 (5)
P T P T
A B A B
D1V*8 45 (12) D1V*81 30 (8)
P T P T
A B A B
Quantity Required
A,C,D B,E,F H,K,M
Hirschmann – Female Connector
692915 Gray (Solenoid A) 1 – 1
692914 Black (Solenoid B) 1 1 –
D1.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#004 spool) at 138 Bar (2000 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “004”. At 138 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(2000 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
57 LPM (15 GPM). At 207 Bar (3000 PSI), the flow 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
is 49 LPM (13 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#008 spool) at 83 Bar (1200 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “008”. At 83 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(1200 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
57 LPM (15 GPM). At 207 Bar (3000 PSI), the flow is 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
19 LPM (5 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#081 spool) at 83 Bar (1200 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “081”. At 83 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(1200 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
42 LPM (11 GPM). At 138 Bar (2000 PSI), the flow is 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
42 LPM (11 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
A
PSI Bar
5000 345
003,004,
011,015
009
300
4000
021,022
Supply Pressure
100 005,016,020
1000
50
0
L/M 10 20 30 40 50 60 70 80 83
0
GPM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Flow
D1.indd, dd
Example:
Determine the maximum allowable flow of a Series
Important Notes for Switching Limit Charts
D1V valve (#009 spool) at 83 Bar (1200 PSI) supply
1. For F & M style valves, reduce flow to 70% of that shown.
pressure. Locate the curve marked “009”. At 83 Bar 2. Shift limits charted for equal flow A and B ports. Unequal
(1200 PSI) supply pressure, the maximum flow is A and B port flows may reduce shift limits.
75 LPM (20 GPM). At 207 Bar (3000 PSI), the flow is 3. These charts do not show explosion proof performance.
Consult factory for explosion proof duty.
68 LPM (18 GPM).
4. Blocking A or B ports will reduce flow by 70%.
D1.indd, dd
D1.indd, dd
D1.indd, dd
D1.indd, dd
Features
• Soft shift available.
• 19 standard spool styles available (for other spools –
Consult Factory).
• Proportional spools.
• DC surge suppression.
• Eight electrical connection options.
• AC & DC lights available (CSA approval for solenoids and
lights).
• Internally ground.
• Easy access mounting bolts.
• Waterproof (meets NEMA 4, up to IP67 on some models). • U.L. recognized available - Contact the division.
• Explosion proof. • No tools required for coil removal.
• CSA approvals. • AC rectified coils.
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6 Leakage Rates* Maximum Allowable:
Mounting DIN 24340-A6 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/Land @
Interface ISO 4401-AB-03-4-A 49°C (120°F) 69 Bar (1000 PSI)*
CETOP R35H 4.2-4-03, 73.8 cc (4.5 Cu. in.) per Minute/Land @
NFPA D03 207 Bar (3000 PSI)*
Maximum P, A, B *#008 and #009 Typical:
Pressure 345 Bar (5000 PSI) Standard Spools may 4.9 cc (0.3 Cu. in.) per Minute/Land @
207 Bar (3000 PSI) 10 Watt exceed these rates. 69 Bar (1000 PSI)*
CSA 276 Bar (3750 PSI) Consult Factory 26.2 cc (1.6 Cu. in.) per Minute/Land @
Tank: 345 Bar (5000 PSI)
103 Bar (1500 PSI) AC only
207 Bar (3000 PSI) DC/AC
Rectified Standard Response Time
207 Bar (3000 PSI) AC Optional Response time (milliseconds) at 345 Bar (5000 PSI) is
CSA 103 Bar (1500 PSI) 32 LPM (8.5 GPM).
Solenoid Type Pull-In Drop-Out
AC 13 20
DC 10 Watt 61 22
DC 30 Watt 51 21
Spool Center Condition
Orifice Closed Open 2-Position
Soft Shift Size Energize De-Energize Energize De-Energize Energize De-Energize
S2 0.020 125 ms 920 ms 200 ms 275 ms 51 ms 100 ms
S5 0.050 51 ms 675 ms 50 ms 27 ms 51 ms 21 ms
D1.indd, dd
NFPA D03 Code Description Code Description Code Description Code Description
CETOP 3 W* Solenoid, N Nitrile A** 24/50 VAC Q** 100/60 VAC
DIN NG6 Wet Pin, V Fluorocarbon D 120 VDC QD† 100/60 - 100/50 VAC
Screw-in
E* EPR G 198 VDC R 24/60 VAC
HW* Reversed
* Contact HVD for J 24 VDC T 240/60 - 220/50 VAC
Wiring
availability. K 12 VDC U 98 VDC
* Valve schematic symbols are per NFPA/
L 6 VDC Y 120/60 - 110/50 VAC
ANSI standards, providing flow P to A when
energizing solenoid A. Note operators reverse N*** 220/50 VAC Z 250 VDC
sides for #008 and #009 spools. See installation P*** 110/50 VAC
information for details. To configure per DIN ** High Watt only
standards (A coil over A port, B coil over B port) *** Explosion Proof only.
code valves as D1VHW***. † Available in DIN only.
010 082
* 020, 026 and 030 spools only.
P T P T † 020 and 030 spools only.
* 008, 020 & 026 spools have closed crossover. ‡ High Watt only.
** 009 & 030 spools have open crossover.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
87.8
(3.46)
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
D1.indd, dd
t
Note: A
u
163.7 2 black wires
(6.44) 18 Inch Lead 1 green wire
O
60.4
(2.38) Wires Standard
e
1/2" NPT
a s
94.4
(3.72)
130.8
(5.15)
P h 304.4
(11.98)
Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve.
46.0
(1.81)
73.0 (2.87)
15.1 (0.61)
7.5 (0.30)
113.0
(4.45)
131.7
(5.19)
100.9
(3.97) 100.6
(3.96)
42.8
(1.69)
7.5 (0.30)
141.0 (5.55)
46.0 (1.81)
73.5 (2.89) 324.7 (12.78)
D1.indd, dd
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
Monitor Switch
(Variation I7 and I8)
This feature provides for electrical confirmation of
the spool shift. This can be used in safety circuits,
to assure proper sequencing, etc.
Switch Data
Inductive switch requiring +18-42 volt input.
Outputs “A” and “B” are opposite; one at “0”
voltage, the other at input voltage. During
switching, “A” and “B” outputs reverse. Provides
0.4A switching current.
For repetitive switch power-up conditions, please consult factory.
D1.indd, dd
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
A Bolt Kits for use with D1V Directional Control Valves, "ET" Explosion Proof & Sandwich Valves
(D1V*-91, 82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated)
Number of Sandwich Valves @40mm (1.58") thickness
0 1 2 3 4
BK209 1.25 in. BK243 2.88 in. BK225 4.38 in. BK244 6.00 in. BK245 7.50 in.
0
BKM209 30 mm BKM243 70 mm BKM225 110 mm BKM244 150 mm BKM245 190 mm
Number of Sandwich Valves at
BK246 3.00 in. BK247 4.62 in. BK248 6.12 in. BK249 7.75 in.
44.5mm (1.75") Thickness
1
BKM246 75 mm BKM247 115 mm BKM248 155 mm BKM249 195 mm
BK250 4.75 in. BK251 6.38 in. BK252 7.88 in.
2
BKM250 120 mm BKM251 160 mm BKM252 200 mm
BK253 6.50 in. BK254 8.12 in.
3
BKM102 170 mm BKM254 205 mm
BK103 8.25 in.
4
BKM103 210 mm
Note: All bolts are SAE Grade 8, 10-24 UNC 2A thread (Metric-M5-0.8)
Torque to 5.6 Nm (50 in-Lb).
Bolt Kits for use with D1V Directional Control Valves with Explosion Proof Coils & Sandwich Valves
(D1V*-91, 82 & 70/75 Design) Except "ET" Coil
Number of Sandwich Valves @40mm (1.58") thickness
0 1 2 3 4
BK50 2.00 in. BK211 3.63 in. BK101 5.12 in. BK102 6.75 in. BK103 8.25 in.
0
BKM50 50 mm — BKM101 130 mm BKM102 170 mm BKM103 210 mm
Number of Sandwich Valves at
BK51 3.75 in. BK212 5.37 in. BK105 6.87 in. BK106 7.75 in.
44.5mm (1.75") Thickness
1
BKM51 95 mm — BKM105 180 mm BKM106 195 mm
BK52 5.50 in. BK213 7.13 in. BK108 8.62 in.
2
BKM52 140 mm — BKM108 220 mm
BK53 7.25 in. BK214 8.87 in.
3
BKM53 185 mm —
BK54 9.00 in.
4
BKM54 230 mm
Note: All bolts are SAE Grade 8, 10-24 UNC 2A thread (Metric-M5-0.8)
Torque to 5.6 Nm (50 in-Lb).
D1.indd, dd
Features P T
• Low pilot pressure required.
D1VA – 4.1 Bar (60 PSI) minimum
D1VP – 15.2 Bar (220 PSI) minimum
Air Operated
Shift Volume. The air pilot chamber requires a volume
of 1.8 cc (.106 in.3) for complete shift from center to
end.
Pilot Piston. The pilot piston area is 506 mm2 (.785
in.2). Pilot piston stroke is 3.4 mm (.135 in.).
Response Time. Response time will vary with pilot
line size, pilot line length, pilot pressure, air control
valve shift time and air valve flow capacity (Cv). Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Oil Operated Operating: 345 Bar (5000 PSI)
Maximum
Shift Volume. The hydraulic pilot chamber requires Pressure Tank Line: D1VA 34 Bar (500 PSI)
a volume of 0.7 cc (.042 in.3) for complete shift from D1VP 207 Bar (3000 PSI)
center to end. Maximum Flow See Reference Data
Pilot Piston. The hydraulic piston area is 198 mm2 D1VA:
Air Minimum 4.1 Bar (60 PSI)
(.307 in.2). Pilot piston stroke is 3.4 mm (.135 in.).
Pilot Pressure Air Maximum 10.2 Bar (150 PSI)
Response Time. Response time will vary with pilot D1VP:
line size, pilot line length, pilot pressure, pilot valve Oil Minimum 15.2 Bar (220 PSI)
shift time and oil valve flow capacity (GPM). Oil Maximum 207 Bar (3000 PSI)
23.0
Y
(0.91)
15.5 9.0
42.0 1/4 BSPP (90) (0.35)
(1.65) (0.61) 43.0 22.0
or (1.70) (0.87)
16.9
min.
(0.67)
SAE #4
Note: 22.0 mm (0.87”) from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
A Directional
Control
Valve
Basic
Valve
Actuator Spool Style Seal Variations Design
Series
NOTE:
Not required
when ordering.
Code Description
Code Symbol N Nitrile
A B V Fluorocarbon
001
P T
A B
002
Code
Description Symbol
P T
A B Single operator, two position
004 B# spring offset.
P to A and B to T in offset position.
P T
A B Double operator,
008* C three position,
P T
spring centered.
A B
D Double operator,
009**
two position, detent.
P T
A B Two position, spring centered.
020* E# P to B and A to T
P T in shifted position.
A B Single operator, two position,
026* H# spring offset. P to B and A to T
P T in offset position.
A B Two position, spring centered.
030** K# P to A and B to T
P T in shifted position.
A B
# D available with 020 and 030 spools only.
081 B & H available with 020, 026 and 030 spools only.
P T E & K not available with 020, 026 and 030 spools.
A B
Code Symbol
Code Description
A B
001 N Nitrile
V Fluorocarbon
P T
A B
002
P T Code
Description Symbol
A B
Single operator, two position b A B
004 B spring offset.
P T P to A and B to T in offset position. P T
A B
Double operator, b A B a
008* C three position,
P T spring centered. P T
A B
b A B a
009** D Double operator,
two position, detent.
P T
P T
A B
b A B
Two position, spring centered.
081
E P to B and A to T
P T in shifted position. P T
A B A B a
Single operator, two position,
082
H spring offset. P to B and A to T
P T in offset position. P T
A B a
* 008 spool has closed Two position, spring centered.
crossover. K P to A and B to T
** 009 spool has open in shifted position. P T
crossover.
Valve schematic symbols are per NFPA/
ANSI standards, providing flow P to A when
energizing operator A. Note operators reverse
sides for #008 and #009 spools. See installation This condition varies
information for details. with spool code.
117.8 (4.64)
61.6
104.55 (4.12)
(2.43)
38.5
192.5 (1.52)
(7.58)
51.95
(2.05)
23.8
(0.94)
23.0 (0.91)
46.0
Note: 22.0 mm (0.87") from bottom of bolt (1.81)
hole counterbore to bottom of valve.
D1.indd, dd
Features
• Choice of 2 cam roller positions (D1VC and D1VD)
• Two styles available (D1VC and D1VG)
• Short stroke option
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Nominal Flow 32 LPM (8.5 GPM)
Maximum Flow See Reference Data
Force Required D1VC, D1VD: 107 N (24 lbs.)
to Shift D1VG: 36 N (8 lbs.)
Maximum
Cam Angle 30°
Ordering Information
D 1V
Directional Basic Actuator Spool Style Seal Variations Design
Control Valve Series
Valve NOTE:
Not required
NFPA D03 Code Symbol Code Description when ordering.
CETOP 3 A B N Nitrile
001 V Fluorocarbon
P T
A B
Code Description
002
P T
Omit Standard
A B P05 Short Stroke
004 P10* Monitor Switch
Code Description
P T * Not CE or CSA approved.
C Cam (90° to A B
mounting surface)
008* Code Description Symbol
D Cam parallel to
mounting surface
P T
Two position, A B
G Cam Lever
A B B spring offset operator
009† at “A” port end. P T
P T Two position, A B
A B H spring offset operator
081 at “B” port end. P T
Valve Weight: Type C & D 1.44 kg (3.2 lbs.) P T
Type G 1.6 kg (3.7 lbs.) Valve schematic symbols are per NFPA/
A B
Standard Bolt Kit: BK209 1–24x1.25 ANSI standards, providing flow P to A when
082
energized. Note flow paths reverse sides for
Metric Bolt Kit: BKM209 M5–0.8x30mm P T #008 and #009 spools.
Seal Kit:
* 008 spool has closed crossover.
Nitrile SKD1VC
† 009 spool has open crossover.
Fluorocarbon SKD1VCV
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
D1.indd, dd
38.5 38.4
Over-Travel (1.51)
(1.52) Full Spool Travel
Pre-Travel
Over-Travel
Full Spool Travel
Pre-Travel 38.5
(1.52)
38.5
(1.52)
79.1
(3.11)
52.0
(2.05)
See 23.8
Note (0.94)
Features
• Spring return or detent styles available
• Heavy duty handle design
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Reference Data
Force Required
to Shift Lever 25 N (5.6 lbs)
Operator
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
15.5
8.9° (0.61)
85.5 Full Shift
(3.37) 15.5
(0.61)
150.6
38.6 (5.93)
(1.52)
50.0
46.0 (1.97)
(1.81) 23.8
See
Note (0.94)
149.5 23.0
(5.89) (0.91)
46.0
(1.81)
Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve.
D1.indd, dd
A Directional
Control
Valve
Basic
Valve
Operator
Type and Location
Spool Style Seal Variations Design
Series
NOTE:
Not required
when ordering.
D1.indd, dd
A 51.00
(2.000) M5-0.8 (10-24) UNC-2B thread
min. x 10.40 (.410) min. thread depth
40.50
(1.594) 4-holes
0.28
33.00
(0.011) S A B
(1.300)
30.20
5.10 (1.190)
(0.200)
21.50
(0.850)
0.75
(0.030) B
O 7.5 (.295) max.
A P.A.B. & T ports
T 0.56
15.50 (0.022)
L A B
31.00 (0.610)
43.00 (1.220)
(1.70) A
min.
25.90
(1.020) O 3.86/4.27 (.152/.168)
31.75 B x 4.00 (.160) min. depth
(1.250)
0.28
(0.011) S A B
P
12.70
(0.500)
4.80 (0.190) R. max. typ.
4 places
D1.indd, dd
D1.indd, dd
A A ctuation
Size
Solenoid
DIN NG6 / CETOP 3 / NFPA D03
De-energized: approx. 60 ms
Electrical Characteristics
M ounting Interface DIN 24340 A6 / ISO 4401 / CETOP uty Ratio
D See Diagram
RP 121-H / NFPA D03 Max. Switching 2000 1/h
Mounting Position Unrestricted Frequency
Ambient -25°C to +50°C (-13°F to +122°F), Protection Class IP 65 in accordance with DIN 40050
Temperature observe permissible duty cycle (plugged and mounted)
Hydraulic Code K J U* G*
Max. Operating 350 Bar (5075 PSI) (P, A, and T) Supply Voltage 12 VDC 24 VDC 98 VDC 205 VDC
Pressure Tolerance Supply ±10% ±10% ±10% ±10%
Fluid Hydraulic oil in accordance with DIN Voltage
51524 / 51525 Current 1.95A 1.1A 0.25A 0.13A
Fluid Temperature -25°C to +70°C (-13°F to +158°F) Consumption
Viscosity Permitted 10...500 cSt / mm²/s (46...2318 SSU) Power Consumption 23.4 W 26.4 W 24.3 W 26.6 W
Recommended 30...80 cSt / mm²/s (139...371 SSU) Solenoid Connector as per EN 175301-803
Filtration ISO 4406 (1999); 18/16/13 C onnection
(meet NAS 1638: 7) Min. Wiring 3 x 1.5 mm2 recommended
Internal Leakage 3-5 DPM per seat Max. Wiring Length 50m (164') recommended
Maximum Flow 20 LPM (5.28 GPM) (at ∆p = 10 bar)
* For a silicon bridge rectifier, set up apart from unit for connecting to a 50 or 60 Hz power supply, 110 V~(98=) or 230V~ (205V=).
With electrical connections the protective conductor (PE ) must be connected according to the relevant regulations.
D1.indd, dd
PSI Bar
290 20
Performance Curve p-Q °F
176
°C
80
Duty Cycle vs. Ambient Temperature
A
232 16 158 70
Ambient Temperature
Pressure Drop
140 60
174 12
122 50
116 8
104 40
58 4
86 30
0
LPM 10 20 30 40 50 30 40 50 60 70 80 90 100
0
GPM 2.6 5.3 7.9 10.6 13.2 Rel. ED % " 5 min.
Flow Q
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Ø 9.0
(0.35)
22.0
58.0 (0.87)
(2.28)
M8 45.0
(1.77)
A P B
14.0
(0.55)
62.0 5.0
(2.44) (0.20)
P
35.0
(1.38) 45.0
A B (1.77)
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D1.indd, dd
Series D3 hydraulic directional control valves are high • Easy access mounting bolts.
A performance, direct operated 4-way valves, available • 345 Bar (5000 PSI) pressure rating.
in 2 or 3-position. They are manifold mounted which
conform to NFPA’s D05, CETOP 5, ISO NG10 mount-
• Flows to 40 GPM depending on spool.
ing patterns. These valves were designed for industrial • Choice of four operator styles.
and mobile hydraulic applications which require high • Rugged four land spools.
cycle rates, long life and high efficiency. • Low pressure drop.
Operation • Phosphate finish body.
Series D3 directional control valves consist of a • CSA approved and UL recognized available.
4-chamber style body, and a case hardened sliding • Proportional spool available.
spool. The spool is directly shifted by a variety of op-
erators including: solenoid, lever, cam, or air pilot.
• Wired in cavity.
• Easy access mounting bolts.
• 22 spool styles available.
• Three electrical connection
options.
• AC and DC lights available.
• CSA approved.
• Available in low-watt DC
version.
D3.indd, dd
D3.indd, dd
Series D3DW hydraulic directional control valves are Series D3DW directional control valves consist of a
A high performance, direct operated 4-way valves, avail-
able in 2 or 3-position. They are manifold mounted
5-chamber style body, and a case hardened sliding
spool.
which conform to NFPA’s D05, CETOP 5, ISO NG10
mounting pattern. These valves were designed for
industrial and mobile hydraulic applications which re-
quire high cycle rates, long life and high efficiency.
D3.indd, dd
Maximum Flow, LPM (GPM)
350 Bar (5000 PSI)
w/o Malfunction
Maximum Flow, LPM (GPM)
350 Bar (5000 PSI)
w/o Malfunction
A
Model Spool Symbol D3W D3W*F† D3DW Model Spool Symbol D3W D3W*F† D3DW
A B A B
D3*1 P T 150 (40) 78 (20) 130 (33) D3*12 P T 95 (24) 59 (15) 75 (19)
A B A B
D3*2 P T 150 (40) 78 (20) 115 (30) D3*14 P T 50† (13) 59# (15) 70† (18)
A B A B
D3*3 P T 150 (40) 78 (20) 120 (31) D3*15 P T 150 (40) 78 (20) 120 (31)
A B A B
D3*4 P T 150 (40) 59 (15) 130 (33) D3*16 P T 150 (40) 78 (20) 130 (33)
A B A B
D3*5 P T 150 (40) 78 (20) 130 (33) D3*20 P T 150 (40) 78 (20) 130 (33)
A B A B
D3*6 P T 150 (40) 78 (20) 130 (33) D3*21 P T 115 (30) N/A 120 (31)
A B A B
D3*7
P T 50† (13) 59# (15) 70† (18) D3*22 P T 115 (30) N/A 120 (31)
A B A B
D3*8 P T 50‡ (13) 59# (15) 39 (10) D3*26 P T 115 (30) N/A 75 (19)
A B A B
D3*9 P T 39 (10) 59# (15) 75 (19) D3*30 P T 39 (10) 59# (15) 75 (19)
A B A B
D3*10 P T 115 (30) N/A 75 (19) D3*81 P T 115† (30) N/A 130 (33)
A B A B
D3A, D3C, D3L Spool Reference Data (Four Chamber Body Only)
Maximum Flow, LPM (GPM) Maximum Flow, LPM (GPM)
350 Bar (5000 PSI) 350 Bar (5000 PSI)
Model Spool Symbol w/o Malfunction Model Spool Symbol w/o Malfunction
A B A B
D3*1
P T 150 (40) D3*20 P T 150 (40)
A B A B
D3.indd, dd
A PSI Bar
5000 345
9, 30 10, 21,
22, 26
300
4000
Supply Pressure
7, 14
150 8, 9, 30
2000
100
1000
50 20D, 26D 1, 2, 3,
30D 4, 5, 6,
15, 16, 20
0
LPM 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
0
GPM 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
Flow
Example:
Determine the maximum allowable flow of a D3W Important Notes for Switching Limit Charts
Series valve (20D) at 150 Bar (2175 PSI) supply 1. For F & M style valves, reduce flow to 70% of that shown.
2. Shift limits charted for equal flow A and B ports. Unequal
pressure. Locate the curve marked “20D”. At 150 Bar A and B port flows may reduce shift limits.
(2175 PSI) supply pressure, the maximum flow is 3. These charts do not show explosion proof performance.
98 LPM (25 GPM). At 345 Bar (5000 PSI), the flow is Consult factory for explosion proof duty.
72 LPM (18.5 GPM). 4. Blocking A and B ports will reduce flow to 70% of that shown.
PSI Bar
3000 200
Supply Pressure
150 4
2000
100
1, 2, 3,
1000 7, 8, 9 5, 6,
50 11, 12, 14, 15, 16, 20
30
0
LPM 10 20 30 40 50 60 70
0
GPM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Flow
D3.indd, dd
PSI Bar
5000 345
A
1, 3, 4, 5,
15, 16, 11
2
300 20, 30
4000
6
Supply Pressure
250 3, 4, 5,
15, 16, 30 1, 6, 20
3000
200
150 9 12
2000
100 7, 8,
14
1000
50 20D,
30D
0
LPM 10 20 30 40 50 60 70 80 90 100 110 120
0
GPM 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Flow
A
Response Time*
Signal to 95% spool stroke measured at
172 Bar (2500 PSI) and 65 LPM (17 GPM).
Soft Shift
Option Energize De-energize
S3 400 650
S4 320 550
S7 160 370
* For reference only. Response time varies
with flow, pressure and oil viscosity.
D3.indd, dd
D3.indd, dd
Features
• Worldwide, high flow, low pressure drop design.
• Soft shift available.
• 22 spools available including proportional.
• DC surge suppression available to protect electrical
equipment.
D3.indd, dd
A Directional
Control Valve
Basic Valve Actuator Spool Style Seal Solenoid
Voltage
2 15
P T P T Code Description Symbol
A B A B
Single solenoid, 2 position, b A B
3 16 B* spring offset.
P T P T P to A and B to T in offset position P T
A B A B b A B a
4
20* C Double solenoid, 3 position,
P T P T spring centered. P T
A B A B b A B a
8*
30** H* spring offset.
9** P to B and A to T in offset position. P T
P T P T
A B a
A B A B Single solenoid, 2 position.
10† 81† K Spring centered.
†† P to A and B to T when energized. P T
P T P T
A B a
A B A B
Single solenoid, 2 position, spring offset, energized
11 82† M** to center position. Spool spacer on B side. P to B
†† and A to T in spring offset position. P T
P T P T
* Only spools 20, 26 & 30.
A B
** High Watt Coil.
12 † Only spools 20 & 30. This condition varies
P T
with spool code.
* 8, 20 & 26 spools have closed crossover.
** 9 & 30 spools have open crossover.
† Available only with high-watt rectified AC coils
or high-watt DC coils.
†† Spring centered versions C, E, F, K & M only.
Solenoid
Connection
Solenoid/Tube
Options
Manual
Override
Options
Electrical Shift
Options Response
and
Approvals Variations Design
Series
NOTE:
A
Indication Not required
Code Description when ordering.
C** Conduit Cavity Code Description
K Conduit Box Omit Standard Valve
J#* Deutsch (DT06-2S) Code Description 3*† CSA US (UL429)
P Hirschmann w/Plug Omit Standard Tube 4* CSA Canada
W* Hirschmann w/o Plug P* Extended Manual * Not available with AC high
E* Explosion Proof Override pressure tube.
* Lights not available. * Not available with soft shift † B, C, H styles only.
** No variations (See “K”). or explosion proof. Y voltage with conduit
# DC voltage only. connection only, must be
rectified.
D3.indd, dd
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
Bolthole
M20 x 1.5-6H Metric Thread Centerline
Reference
Ground Stud
134.7
(5.31)
103.6 18.9
(4.08) (0.74)
11.6
36.0 (0.46)
(1.42)
18.9 (0.74) Ref.
11.3
23.0 Bolthole 23.0 (0.44)
(0.91) 12.1 Centerline (0.91) 64.9 (2.56)
58.1 (0.47) Reference 75.6 (2.98) 76.7 (3.02)
(2.29) 154.1 207.7
(6.07) (8.18)
Note: Mounting bolts included with valve.
D3.indd, dd
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
Monitor Switch
(Variation I7) End of Stroke
D3.indd, dd
Manaplug
(valve variations 6, 56, 1A, 1C)
Interface – Brad Harrison Plug
– 3-Pin for Single Solenoid
– 5-Pin for Double Solenoid
Ground
Wire #1 (Green)
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
Pin #1
(Negative)
Pin #2
(Positive)
D3.indd, dd
Features
• 22 spools available including proportional.
• DC surge suppression available to protect electrical
equipment.
• Easy access mounting bolts.
• CSA approved.
• No tools required for coil removal.
• High pressure tank line capability.
• Monitor switch available.
Specifications
Response Time (ms) Interface NFPA D05, CETOP 5, NG 10
Signal to 95% spool stroke measured at Max. Operating P, A, B:
175 Bar (2500 PSI) and 75 LPM (20 GPM) Pressure 345 Bar (5000 PSI) Standard
CSA 207 Bar (3000 PSI)
Solenoid Type Pull-In Drop-Out
DC 110 85 Tank:
207 Bar (3000 PSI) Standard
CSA 103 Bar (1500 PSI)
Maximum Flow See Spool Reference Chart
Leakage Rates Maximum Allowable:
Solenoid Ratings** 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/
49°C (120°F) Land @ 69 Bar (1000 PSI)*
Insulation Class H
Allowable Deviation DC only 73.8 cc (4.5 Cu. in.) per Minute/
Land @ 207 Bar (3000 PSI)*
from rated voltage -10% to +15%
Armature Wet pin type Typical:
** DC Solenoids available with optional molded metal oxide varistor
4.9 cc (0.3 Cu. in.) per Minute/
(MOV) for surge suppression. Land @ 69 Bar (1000 PSI)*
26.2 cc (1.6 Cu. in.) per Minute/
Land @ 345 Bar (5000 PSI)
D3.indd, dd
A Directional
Control Valve
Basic
Valve
Body Actuator Spool Style Seal Solenoid
Voltage
NFPA D05
CETOP 5 Code Description
NG 10 K 12 VDC
J 24 VDC
5-Chamber D 120 VDC
Body
Y* 120/60 AC
110/50
T* 240/60 AC
Wet armature
220/50
solenoid
* Must be rectified.
2 15
P T P T
A B A B Code Description Symbol
b A B
3 16 Single solenoid, 2 position,
P T P T B* spring offset.
A B A B P to A and B to T in offset position P T
b A B a
4 20*
P T P T
C Double solenoid, 3 position,
A B A B
spring centered. P T
b A B a
5 21
D† Double solenoid, 2 position, detent
P T P T
P T
A B A B
b A B
6 22 Single solenoid, 2 position,
E spring centered.
P T P T
P to B and A to T when energized. P T
A B A B
b A B
7 26* Single solenoid, 2 position. Spring offset,
F energized to center. Position spool spacer on
P T P T
A B
A side. P to A and B to T in spring offset position. P T
A B
A B a
8* 30** Single solenoid, 2 position,
9** H* spring offset.
P T P T
A B A B
P to B and A to T in offset position. P T
A B a
10 81 Single solenoid, 2 position.
K Spring centered.
P T P T
A B A B
P to A and B to T when energized. P T
A B a
11 82 Single solenoid, 2 position, spring offset, energized
P T
M to center position. Spool spacer on B side. P to B
P T
and A to T in spring offset position. P T
A B
Solenoid
Connector
Manual
Override
Options
Electrical
Options
Shift
Indication
Approvals Variations Design
Series
NOTE:
A
Not required
when ordering.
Code Description
Code Description
Omit Standard Valve
P Hirschmann w/Plug
5 Signal Lights
W* Hirschmann w/o Plug
* Not available with signal lights.
Code Description
Omit Standard Valve
4 CSA Approval
Code Description
Omit Standard Valve
I7* Monitor Switch
* Single solenoid models only.
Not CE or CSA approved.
Not available with spools 8,
9, 81 & 82.
106.2
83.0 (4.18)
(3.27) 87.8
(3.46)
36.0
(1.42)
12.0 21.5
(0.47) 23.0 (0.85)
58.9 (0.91) 80.1 76.2
(2.29) (3.16) (3.00)
122.5 177.2
(4.83) (6.98)
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
83.0 88.2
(3.27) (3.48)
36.0 See
(1.42) Note
12.0 21.5
23.0 (0.47) (0.85)
40.5 76.2
58.0 (0.91)
(1.60) (3.00)
(2.29) 122.5 87.9
(4.83) (3.46)
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
Monitor Switch
(Variation I7) End of Stroke
D3.indd, dd
Specifications
Mounting Pattern NFPA D05, CETOP 5, NG 10
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Spool Reference Chart
Pilot Pressure Air Minimum 4.1 Bar (60 PSI)
Air Maximum 6.9 Bar (100 PSI)
Response Time* (ms)
Signal to 95% spool stroke measured at
172 Bar (2500 PSI) and 75 LPM (20 GPM)
Air Operated
Shift Volume. The air pilot chamber requires a volume of Pilot Pressure Pull-In Drop-Out
1.8 cc (.106 in.3) for complete shift from center to end. 60 PSI 23.0 ms 23.0 ms
Pilot Piston. The pilot piston area is 506 mm2 (.785 in.2). 100 PSI 19.0 ms 38.0 ms
Pilot piston stroke is 3.4 mm (.135 in.).
* Chart is for reference only. Response time will vary with pilot line
size, length, air pressure and air valve flow capacity (Cv).
D3.indd, dd
Code Description
N Nitrile
Code Symbol Code Symbol V Fluorocarbon
A B A B
1 20*
P T P T
A B A B Code Description Symbols
2 30† Single operator, two position b A B
P T P T
B # spring offset.
A B A B P to A and B to T in offset position.
P T
4 81 Double operator, b A B a
P T P T C three position,
A B A B spring centered.
P T
8* 82 Double operator, b A B a
P T P T D # two position,
A B detent. P T
9†
Two position, spring centered. b A B
P T E P to B and A to T
* 8 and 20 spools have closed crossover. in shifted position. P T
† 9 and 30 are open crossover. Single operator, two position, A B a
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
Ordering Information
D 3
Directional Basic Valve Actuator Spool Style Seal Variations Design
Control Valve Series
NOTE:
Not required
when ordering.
NFPA D05
CETOP 5
NG10 Code Description Code Description
N Nitrile Omit Standard
V Fluorocarbon B5 Short Stroke
Code Description
C Cam (90° to
mounting surface)
D Cam parallel to
mounting surface Code Description Symbol
Two position, A B
A
UNC Bolt Kits for use with D3C & D3D
Directional Control Valves & Sandwich Valves
Number of Sandwich Valves
@ 2.00” (50mm) thickness
0 1 2 3
D3C, D3D Standard: BK98 BK141 BK142 BK143
1.62” 3.50” 5.50” 7.50”
Metric: BKM98 BKM141 BKM142 BKM143
40mm 90mm 140mm 190mm
NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to
16 Nm (12 ft-lbs)
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Cam Operated
Full
Valve Type Pre-Travel Spool Over-Travel
Travel
Standard 1.75 5.75 2.03
Valve (0.07) (0.23) (0.08)
B5 0 4.00 2.03
Short Stroke (0) (0.16) (0.08)
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
A
Series D3L directional control valves are high perfor-
mance, 4-chamber, direct operated, lever controlled, A B
4-way valves. They are available in 2 or 3-position and
conform to NFPA’s D05, CETOP 5 mounting patterns.
P T
Features
• Spring return or detent styles available.
• High flow, low pressure drop design.
• Heavy duty handle design.
Specifications
Mounting Pattern NFPA D05, CETOP 5, NG 10
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Spool Reference Chart
Force Required
to Shift Lever 173 N (39 lbs.)
Operator
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
D3.indd, dd
A Directional
Control Valve
Basic Valve Operator
Type & Location
Spool Style Seal Variations Design
Series
NOTE:
Not required
NFPA D05 when ordering.
CETOP 5
NG10
Code Description
Omit Standard
I7* Monitor Switch
Operator Location (A or B End)
Code Operator Type For Valve Style * Not available on C, D or
B C D E H K N N styles. Not CE or CSA
Code Description approved.
L Lever (Standard) B B B A B B B N Nitrile
LB Lever (Alternate) A A A N/A A N/A A V Fluorocarbon
A 91.2
(3.62)
-B-
54.0
(2.13)
50.8
(2.00)
37.3
(1.47)
27.0
(1.06) 16.7
(0.66)
21.4 6.4 3.2
(0.84) (0.25) (0.13)
D3.indd, dd
D3.indd, dd
Series D31 hydraulic directional control valves are • Easy access mounting bolts.
A high performance, solenoid controlled, pilot operated,
2-stage, 4-way valves. They are available in 2 or • 345 Bar (5000 PSI) pressure rating.
3-position styles and are manifold mounted. These • Flows to 175 LPM (45 GPM) depending on spool.
valves conform to NFPA’s D05H, CETOP 5 and can
also be manufactured to an NFPA DO5HE, CETOP 5H • Choice of four operator styles.
configuration. • Rugged four land spools.
Operation • Low pressure drop.
Series D31 directional valves consist of a 5-chamber
style main body, a case hardened sliding spool, and a
• Phosphate finish.
pilot valve or pilot operators (hydraulic or pneumatic). • Both NFPA and CETOP mounting
styles available.
D31.indd, dd
Specifications
Mounting Pattern NFPA D05H, CETOP 5
NFPA D05HE, CETOP 5H
Max. Operating 345 Bar (5000 PSI) Standard
Pressure 207 Bar (3000 PSI) 10 Watt
CSA 207 Bar (3000 PSI)
Max. Tank Line Internal Drain Model:
Pressure 103 Bar (1500 PSI) AC Std.
207 Bar (3000 PSI) DC Std./AC Opt.
Response Time
External Drain Model: Response time (milliseconds)
207 Bar (3000 PSI) at 345 Bar (5000 PSI) is 76 LPM (20 GPM)
CSA 103 Bar (1500 PSI)
Solenoid Pilot
Max. Drain 103 Bar (1500 PSI) AC only Type Pressure Pull-In Drop-Out
Pressure 207 Bar (3000 PSI) DC Std./AC Opt.
500 40 50
CSA 103 Bar (1500 PSI)
DC 1000 36 50
Min. Pilot Pressure 6.9 Bar (100 PSI)
2000 34 50
Max. Pilot Pressure 345 Bar (5000 PSI) Standard
500 20 33
CSA 207 Bar (3000 PSI) AC 1000 18 33
Nominal Flow 76 Liters/Min (20 GPM) 2000 13 33
Maximum Flow See Switching Limit Charts
4000 276
Suppl y Pressure
3000 207
9 with
9 150 PSI Pilot
2000 138
8
1000 69
0
LPM 38 76 113 151 189
0
GPM 10 20 30 40 50
Flow
Note: Internal Drain
1, 4 spools – 113 LPM (30 GPM) max., 2, 9 & 14 spools – per curve
All others – 95 LPM (25 GPM) max.
D31.indd, dd
A Directional
Control Valve
Basic Valve Actuator Spool Style Pilot Supply
and Drain
Seal Solenoid
Voltage
A B A B b A B
F† Single solenoid, 2 position, spring offset,
005 016 energized to center. Spacer on A side.
P T P T P to A and B to T in offset position. P T
A B A B
A B a
006 020* H* Single solenoid, 2 position, spring offset.
P T P T P to B and A to T in offset position.
P T
A B A B A B a
007 030** K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
P T P T P T
A B A B A B a
008* 081 M† Single solenoid, 2 position, spring offset,
009** energized to center. Spacer on B side.
P T P T P to B and A to T in offset position. P T
A B A B
010 082 * 020 and 030 spools only.
† High watt only.
P T P T
Solenoid
Connection
Coil
Options
Tube
Options
Manual
Override
Options
Electrical
Options
Shift
Response
and Indication
Approvals Valve
Variations
Design
Series
NOTE:
A
Not required
when ordering.
Code Description Code Description
C* Leadwire Conduit Box Omit Standard See next page for
D** Metric Plug (M12X1), P Extended with Boot Valve Variations
DESINA T† None
E† Explosion Proof † DC or AC rectified only.
G†† Plug-In Conduit Box Code Description
Manual Override options not
J# Deutsch (DT06-2S) Omit Standard Valve
available with Explosion Proof.
M# Metri-Pack (150) 3*† CSA USA
P DIN with Plug 4*# CSA Approved
S# Dual Spade * Not available with AC high
W† DIN w/o Plug pressure tube.
# Valve is derated with this option.
* No variations – See Plug-in. Code Description
† B, C, H styles only. J, K, Y, U
** DC only, lights, diode surge Omit Standard Pressure voltages only with C, G, W
suppressor, not CSA approved. 103.5 Bar (1500 PSI) AC solenoid connections only.
† Not available with lights. 207 Bar (3000 PSI) DC Conforms to UL429.
†† Required for variations on
H* High Pressure, AC only
conduit box style. Must have
207 Bar (3000 PSI)
lights. Code Description
# DC only, no lights, not CSA * Not available with CSA.
Omit Standard Response,
approved. No Switch
I3 Monitor Switch,
Code Description ‘A’ & ‘B’ Port End
Omit* High Watt I6 Monitor Switch,
‘A’ & ‘B’ Port Start
D** Explosion Proof,
EEXD ATEX Note: Not CE or CSA approved.
Spools 008, 009, 081 and
E** Explosion Proof,
082 not available.
EEXME ATEX
F† Low Watt Code Description
L†† 10 Watt Omit No Options
O** Explosion Proof, J* Diode Surge
MSHA Suppressor
T# Explosion Proof, Z† Rectified Coil
Ex d IIC ATEX/CSA * DC only.
U** Explosion Proof, DIN coil must include
UL/CSA plug with lights.
* AC ambient temperature † DC tube standard.
must not exceed 60°C (140°F).
** 60 Hz only on AC, no options.
† AC only. Mounting Bolt Kits
†† DC and AC rectified only.
# J, K and Y voltages only. Dual UNC Bolt Kits for use with D31*W
frequency on AC, no options. Directional Control Valves & Sandwich Valves
Number of Sandwich Valves
@ 2.00” (50mm) thickness
0 1 2 3
Valve Weight: D31*W Standard: BK98 BK141 BK142 BK143
Double Solenoid 5.4 kg (12.0 lbs.) 1.62” 3.50” 5.50” 7.50”
Seal Kit: Metric: BKM98 BKM141 BKM142 BKM143
Nitrile SKD31VWN91 40mm 90mm 140mm 190mm
Fluorocarbon SKD31VWV91 NOTE: All bolts are SAE grade 8. Standard bolts are 1/4-20 UNCA
thread. Metric bolts are M6-1.0 thread. Torque to 16 Nm (12 ft-lbs).
D31.indd, dd
Performance Curves
D31.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D31.indd, dd
u t
e O
a s
P h
D31.indd, dd
73.5
183.9 (2.90)
(7.25)
214.7
(8.46)
125.8
(4.96)
83.0
(3.27)
62.0 36.0
(2.44) (1.42) 35.0
224.4 (1.38)
70.0
(8.84)
(2.76)
D31.indd, dd
D31.indd, dd
Monitor Switch
(Variation I3 and I6)
This feature provides for electrical confirmation of Position Control Switch
the spool shift. This can be used in safety circuits,
to assure proper sequencing, etc. Sensor / Driver
Circuitry
Switch Data PIN 2
Pin 1 and Pin 3 have outputs equal to the input. Input PIN 1
When the monitor switch has the output to Pin 1, 18-42 VDC Outputs
Pin 3 will have an output of zero, and vice-versa. PIN 3
When the valve is switched, Pin 1 and Pin 3 will
switch outputs. Load 0.2 A Max
D31.indd, dd
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
* Please add for each sandwich plate +40mm (1.58") (pressure reducing valve, pilot choke valve meter-in/-out).
The space necessary to remove the plug per DIN 43650, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D31.indd, dd
016
2 positions.
021 M
Operated in position “0”.
Spring offset in Spring offset in
022 position “a”. position “b”.
031
2 positions, detent.
R
032 No center in No center in Operated in position “0” or “b”.
offset position. offset position.
081
2 positions, detent.
082 S Operated in position “0” or “a”.
No center in No center in
offset position. No center in offset position.
offset position.
2-Position Spools
2-Position Spools
Code Spool Type
a b Code Spool Position
D31.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D31.indd, dd
A Actuation
Size
Solenoid
NG10
Mounting Interface DIN 24340 A10 / ISO 4401 / NFPA D05 / CETOP RP 121-H
Mounting Position Unrestricted, preferably horizontal
[°C] -25...+50; (-13°F...+122°F) (without inductive position control)
Ambient Temperature
[°C] 0...+50; (+32°F...+122°F) (with inductive position control)
MTTFD Value [years] 75
Hydraulic
Pilot drain internal: P, A, B, X 315 Bar (4568 PSI); T, Y 140 Bar (2030 PSI)
Maximum Operating Pressure
Pilot drain external: P, A, B, T, X 315 Bar (4568 PSI); Y 140 Bar (2030 PSI)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid Temperature [°C] -25 ... +70 (-13°F...+158°F)
Viscosity Permitted [cSt] /[mm²/s] 2.8...400 (13...1854 SSU)
Recommended [cSt] /[mm²/s] 30...80 (139...371 SSU)
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow Maximum 170 LPM (45 GPM)
Leakage at 350 Bar (per flow path) [ml/min] 72...422 (0.2...0.11 GPM) (depending on spool)
Minimum Pilot Supply Pressure 7 Bar (102 PSI)
Static / Dynamic
Step Response at 85% Energized De-energized
DC Solenoids Pilot Pressure
50 Bar & 100 Bar [ms] 470 390
250 Bar & 350 Bar [ms] 320 390
AC Solenoids Pilot Pressure
50, 100, 250 & 350 Bar [ms] 30 / 50 375
D31.indd, dd
A
Protection Class IP 65 in accordance with EN 60529 (plugged and mounted)
Ambient Temperature [°C] 0...+50; (+32°F...122°F)
Supply Voltage / Ripple [V] 18...42 ±10%
Current Consumption without Load [mA] ≤ 30
Max. Output Current per Channel,
[mA] 400
Ohmic
Min. Output Load per Channel, Ohmic [kOhm] 100
Max. Output Drop at 0.2A [V] ≤ 1.1
Max. Output Drop at 0.4A [V] ≤ 1.6
EMC EN50081-1 / EN50082-2
Max. Tolerance Ambient Field Strength [A/m] <1200
Min. Distance to Next AC Solenoid [m] >0.1
Interface M12x1 per IEC 61076-2-101
Wiring Minimum [mm²] 5 x 0.25 brad shield recommended
Wiring Length Maximum [m] 50 (164 ft.) recommended
1 + Supply 18...42V
2 Out B: normally closed
3 0V
4 Out A: normally open
5 Earth ground
D31.indd, dd
The flow curve diagram shows the flow versus pressure drop curves for all spool types. The relevant curve number
A for each spool type, operating position and flow direction is given in the table below.
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
A
Series D31*A directional control valves are
5-chamber, air pilot operated valves. The valves are
suitable for manifold or subplate mounting.
Features
Specifications
Mounting Pattern NFPA D05H , CETOP 5 Pressure Drop Chart
NFPA D05HE, CETOP 5H
D31VA Pressure Drop Reference Chart -- Curve Number D31VA Pressure Drop vs. Flow
Spool Shifted Center Condition The chart to the left provides the flow vs. pressure drop
No. P-A P-B B-T A-T (P-T) (B-A) (A-B) (P-A) (P-B) (A-T) (B-T) curve reference for the D31VA Series valves by spool type.
001 3 3
2 1 - - - - - - -
002 3 3
1 1 3 3 3 4 4 1 1 Example:
004 3 3
1 1 - - - - - 1 1 Find the pressure drop at 76 LPM (20 GPM) for a D31VA
009 3 3
1 1 6 - - - - - - with a number 001 spool. To the right of spool number 001,
020 5 4
2 2 - - - - - - - locate the number 3 in the P-A column, and 2 in the B-T
030 4 3
1 1 - - - - - - - column.
Using the top graph, locate curves 2 and 3 and read the
pressure drop values. Total pressure drop through the valve
is the sum of the two values.
D31.indd, dd
D A
Directional Basic Valve Air Operated Spool Style Pilot Supply Seal Valve Design
A
Control Valve Pilot and Drain Variations Series
NOTE:
Code Description ode Description Code Description
C Not required
31D NFPA D05HE, N Nitrile Omit Standard when ordering.
CETOP 5H (ISO) V Fluorocarbon 7 Pilot Choke - Meter Out
31V NFPA D05H, 8 Stroke Adj. ‘B’ End
CETOP 5 Code Description 9 Stroke Adj. ‘A’ End
1 Int. pilot/Ext. drain 60 Pilot choke - Meter In
Code Symbol 2 Ext. pilot/Ext. drain 89 Stroke Adj. ‘A’ & ‘B’ Ends
A B
4# Int. pilot/Int. drain 90 1/4 BSPP Threads
Valve schematic symbols 001
5 Ext. pilot/Int. drain
are per NFPA/ANSI P T
A B # Not available with 002, 008 & 009 spools.
standards, providing
002
flow P to A when Code Description Symbol
P T
energizing operator A. A B b A B
Note operators reverse 004 B† Single operator, 2 position, spring offset.
sides for #008 and #009 P T
P to A and B to T in offset position. P T
spools. See installation b A B a
A B C Double operator, 3 position,
information for details. 008†
spring centered.
009* P T b A
P
B
T
a
D† Double operator, 2 position, detent.
A B
P T
Valve Weight: 020† E Single operator, 2 position, spring centered. b A B
Double Operator P T
P to B and A to T when energized.
A B
5.7 kg (12.7 lbs.) P T
Metric Bolt Kit: have closed crossover. K Single operator, 2 position, spring centered. A B a
This condition
BKM98 * 009 and 030 spools P to A and B to T when energized. varies with
have open crossover.
P T
spool code.
Dimensions – Air Operated Inch equivalents for millimeter dimensions are shown in (**)
Features
• World design – Available worldwide.
• Mounting bolts below center line of spool – Minimizes
spool binding.
D31VL Pressure Drop Reference Chart -- Curve Number D31VL Pressure Drop vs. Flow
Spool Shifted Center Condition The chart to the left provides the flow vs. pressure drop
No. P-A P-B B-T A-T (P-T) (B-A) (A-B) (P-A) (P-B) (A-T) (B-T) curve reference for the D31VL Series valves by spool type.
001 3 3
2 1 - - - - - - -
002 3 3
1 1 3 3 3 4 4 1 1 Example:
004 3 3
1 1 - - - - - 1 1 Find the pressure drop at 76 LPM (20 GPM) for a D31VL
009 3 3
1 1 6 - - - - - - with a number 001 spool. To the right of spool number 001,
020 5 4
2 2 - - - - - - - locate the number 3 in the P-A column, and 2 in the B-T
030 4 3
1 1 - - - - - - - column.
Using the top graph, locate curves 2 and 3 and read the
pressure drop values. Total pressure drop through the valve
is the sum of the two values.
D31.indd, dd
D L
Directional Basic Valve Lever Operated Spool Style Pilot Supply Seal Valve Design
A
Control Valve Pilot and Drain Variations Series
NOTE:
Code Description Code Description Not required
when ordering.
31D NFPA D05HE, 1 Int. pilot/Ext. drain
CETOP 5H (ISO) Code Description
Code Symbol 2 Ext. pilot/Ext. drain
31V NFPA D05H, Omit Standard
A B 4# Int. pilot/Int. drain
CETOP 5 001 7 Pilot choke – meter out
5 Ext. pilot/Int. drain
P T 8 Stroke adj. ‘B’ End
A B # Not available with
Code Description 9 Stroke adj. ‘A’ End
Valve schematic symbols 002 002, 008 & 009
are per NFPA/ANSI P T
spools. N Nitrile 60 Pilot choke – meter in
standards, providing A B V Fluorocarbon
89 Stroke adj. ‘A’ & ‘B’ Ends
flow P to A when 004
energizing operator A. P T
Code Description Symbol
Note operators reverse A B
sides for #008 and #009 008** B† Sgl. operator, 2 position, spring offset.
A B
Valve Weight: 5.4 kg (12.0 lbs.) K Sgl. operator, 2 position. Spring centered.
A B
This condition
P to A and B to T in shifted position. varies with
Standard Bolt Kit: BK98 P T spool code.
Metric Bolt Kit: BKM98
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
Dimensions – Lever Operated Inch equivalents for millimeter dimensions are shown in (**)
D31.indd, dd
A
Series D3*P directional control valves are 5-chamber,
oil pilot operated valves. The valves are suitable for
manifold or subplate mounting.
Features
• World design – Available worldwide.
• Mounting bolts below center line of spool –
Minimizes spool binding.
D3P Pressure Drop Reference Chart -- Curve Number VISCOSITY CORRECTION FACTOR
Spool Shifted Center Condition Viscosity (SSU) 75 150 200 250 300 350 400
No. P-A P-B B-T A-T (P-T) (B-A) (A-B) (P-A) (P-B) (A-T) (B-T) % of ∆P (Approx.) 93 111 119 126 132 137 141
1 3 3
2 1 - - - - - - - Curves were generated using 100 SSU hydraulic oil. For any other
2 3 3
1 1 3 3 3 4 4 1 1 viscosity, pressure drop will change as per chart.
4 3 3
1 1 - - - - - 1 1
9 3 3
1 1 6 - - - - - - D3P Pressure Drop vs. Flow
20 5 4
2 2 - - - - - - -
30 4 3
1 1 - - - - - - - The chart to the left provides the flow vs. pressure drop
curve reference for the D3P Series valves by spool type.
Example:
Find the pressure drop at 76 LPM (20 GPM) for a D3P with
a number 1 spool. To the right of spool number 1, locate the
number 3 in the P-A column, and 2 in the B-T column.
Using the top graph, locate curves 2 and 3 and read the
pressure drop values. Total pressure drop through the valve
is the sum of the two values.
D31.indd, dd
D P
Directional Basic Valve Hydraulic Spool Style Pilot Supply Seal Valve Design
A
Control Valve Pilot and Drain Variations Series
NOTE:
Not required
Code Description Code Symbol Code Description when ordering.
3D NFPA D05HE, N Nitrile
CETOP 5H
A B
Code Description
1 V Fluorocarbon
3 NFPA D05H, Omit Standard
P T
CETOP 5 A B 7 Pilot Choke – Meter Out
2 Code Description
8 Stroke Adj. ‘B’ End
P T 2 Ext. pilot/Ext. drain
A B 9 Stroke Adj. ‘A’ End
4 5# Ext. pilot/Int. drain
60 Pilot Choke – Meter In
# Available on “B” and “H” styles only.
P T
89 Stroke Adj. ‘A’ & ‘B’ Ends
A B
8**
9* Code Description Symbol
P T
A B
B† Single operator, 2 position, spring offset.
* 9 and 30 spools have 20** P to A and B to T in offset position.
open crossover. P
A
T
B
** 8 and 20 spools have C Double operator, 3 position,
closed crossover. 30* spring centered.
P T
H† Single operator, 2 position, spring offset.
Valve Weight:
P to B and A to T in offset position.
Single Operator 1.4 kg (3.0 lbs.)
Double Operator 1.6 kg (3.5 lbs.) † Only spools 20 and 30. This condition varies with
spool code.
Standard Bolt Kit: BK98
Metric Bolt Kit: BKM98 Valve schematic symbols are per NFPA/ANSI standards, providing flow P
to A when energizing operator X. Note operators reverse sides for #8 and
Seal Kit:
#9 spool. See installation information for details.
Nitrile SKD3P
Fluorocarbon SKD3PV
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
Dimensions – Oil Operated Inch equivalents for millimeter dimensions are shown in (**)
76.2 47.8
(3.00) (1.88)
# 6 SAE
111.9
(4.40)
83.0
(3.27)
See 36.0
Note (1.42)
DIRECTIONAL CONTROL VALVES Pilot Pressure: 6.9 to 345 Bar (100 to 5000 PSI)
A Tank and Drain Line Surges
Direct pilot operated valves use the “X” and “Y” ports
to supply pilot oil directly to the ends of the spool,
If several valves are piped with a common tank or drain providing spool shifting force. A block mounted on
line, flow surges in the line may cause an unexpected top of the valve body is internally cored to make the
spool shift. Separate tank and drain lines should be necessary connections. Thus when “X” is pressurized,
piped in installations where line surges are expected. “Y” is used as a drain; and when “Y” is pressurized, “X”
becomes the drain.
Any back pressure in these lines when they are
Loss of Pilot Pressure being used as a drain is additive to the pilot pressure
Should oil pilot pressure fail, spring offset and spring requirement.
centered valves will shift to the spring held position.
Detented valves will stay in the last position held Internal Drain: On spring offset models, only the “X”
before power failure. If main flow does not fail or stop port is pressurized, as the spring returns the spool
at the same time power fails, machine actuators may to its at rest position. On these models, “Y” may be
continue to function in an undesirable manner or internally drained through the main tank passage in
sequence. the valve.
Mounting Pattern
D3P valves may be mounted on a standard D05
pattern subplate or manifold only if the “X” and “Y”
ports are externally connected to the pilot block on
top of the main body. All other mounting styles require
a D05H or D05HE pattern which incorporates ports
for the “X” and “Y” pilot and drain passages. Location
of these ports can be found on the Recommended
Mounting Surface pages in this section.
D31.indd, dd
D31.indd, dd
P
57.9 32.5 X
43.6 (1.28) Y
(2.28) 46.0 6.3 (O.25) max. 75.0
min. (1.72) A B
(1.81) X & Y ports (2.95)
T
.56
(.022)
L A B
B
11.2 (O.44) max.
P.A.B. & T ports
.56
(.022)
L A B
D31.indd, dd
D3.indd, dd
Series D41 hydraulic directional control valves are • Easy access mounting bolts.
A high performance, solenoid controlled, pilot operated,
2-stage, 4-way valves. They are available in 2 or 3 po- • 345 Bar (5000 PSI) pressure rating.
sition styles and are manifold mounted. These valves • Flows to 300 LPM (79.4 GPM) depending on spool.
conform to NFPA’s D07, CETOP 7 mounting patterns.
• Choice of three operator styles.
Operation • Rugged four land spools.
Series D41 directional valves consist of a 5-chamber
style main body, a case hardened sliding spool, and a
• Low pressure drop.
pilot valve or oil pilot operator. • Phosphate finish.
D41.indd, dd
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
* Please add for each sandwich plate +40mm (1.58”) (pressure reducing valve, pilot choke valve meter-in/-out).
D41.indd, dd
3-Position Spools
002
Code All 3-Position Spools
003 3 positions.
C Spring offset in position “0”.
004 Operated in position “a” or “b”.
Standard Spool Type 009
005
006 2 positions.
E
Spring offset in position “0”.
Operated in Operated in
007 position “a”. position “b”.
009
2 positions.
F
011 Operated in position “0”.
Spring offset in Spring offset in
position “b”. position “a”.
014
015 2 positions.
K
Operated in Spring offset in position “0”.
016 Operated in
position “b”. position “a”.
021
2 positions.
022 M
Operated in position “0”.
Spring offset in Spring offset in
054 position “a”. position “b”.
A 5*
Signal Lights – Standard
Signal Lights – Hirsch. (DIN with Plug)
7B** Manaplug – Brad Harrison (12x1) Micro with Lights
56** Manaplug (Mini) with Lights
1C** Manaplug (Mini) Single Sol. 5-pin, with Lights
1D** Manaplug (Micro) Single Sol. 5-pin, with Lights
1G** Manaplug (Mini) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1H** Manaplug (Micro) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1M** Manaplug Opposite Normal
1R Stroke Adjust ‘A’ & ‘B’ End with Pilot Choke Meter In
3A Pilot Choke Meter Out
3B Pilot Choke Meter In
3C Pilot Pressure Reducer
3D Stroke Adjust ‘B’ End
3E Stroke Adjust ‘A’ End
3F Stroke Adjust ‘A’ & ‘B’ End
3G* Pilot Choke Meter Out with Lights
3H* Pilot Choke Meter In with Lights
3J* Pilot Pressure Reducer with Lights
3K Pilot Choke Meter Out
with Stroke Adjust ‘A’ & ‘B’ End
3L** Pilot Choke Meter Out, Stroke Adjust ‘A’ & ‘B’ End
with Lights and Manaplug — Brad Harrison Mini
3M Pilot Choke Meter Out, Pilot Pressure Reducer,
Stroke Adjust ‘A’ & ‘B’ End
3R Pilot Choke Meter Out & Pilot Pressure Reducer
3S** Lights and 5-pin Mini Manaplug with Pilot Choke
7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights
* DESINA, plug-in conduit box, and DIN with plug styles only.
** Must have plug-in style conduit box.
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D41.indd, dd
A Actuation
Size
Solenoid
NG16
Mounting Interface DIN 24340 A16 / ISO 4401 / NFPA D07 / CETOP RP 121-H
Mounting Position Unrestricted, preferably horizontal
[°C] -25...+50; (-13°F...+122°F) (without inductive position control)
Ambient Temperature
[°C] 0...+50; (+32°F...+122°F) (with inductive position control)
MTTFD Value [years] 75
Hydraulic
Pilot drain internal: P, A, B, X 350 Bar (5075 PSI); T, Y 105 Bar (1523 PSI)
Maximum Operating Pressure Pilot drain external: P, A, B, T, X 350 Bar (5075 PSI); Y 105 Bar (1523 PSI)
10 Watt 207 Bar (3000 PSI)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid Temperature [°C] -25 ... +70 (-13°F...+158°F)
Viscosity Permitted [cSt] /[mm²/s] 2.8...400 (13...1854 SSU)
Recommended [cSt] /[mm²/s] 30...80 (139...371 SSU)
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow Maximum 300 LPM (79.4 GPM)
Leakage at 350 Bar (per flow path) [ml/min] up to 200 (0.05 GPM) (depending on spool)
Operating Pressure
See p/Q Diagram
Integral Check Valve
Minimum Pilot Supply Pressure 5 Bar (73 PSI)
Static / Dynamic
Step Response at 85% Energized De-energized
DC Solenoids Pilot Pressure
50 Bar [ms] 95 65
100 Bar [ms] 75 65
250 Bar & 350 Bar [ms] 60 65
AC Solenoids Pilot Pressure
50 Bar [ms] 75 55
100 Bar [ms] 65 55
250 Bar & 350 Bar [ms] 40 55
D41.indd, dd
A
Protection Class IP 65 in accordance with EN 60529 (plugged and mounted)
Ambient Temperature [°C] 0...+50; (+32°F...122°F)
Supply Voltage / Ripple [V] 18...42 ±10%
Current Consumption without Load [mA] ≤ 30
Max. Output Current per Channel,
[mA] 400
Ohmic
Min. Output Load per Channel, Ohmic [kOhm] 100
Max. Output Drop at 0.2A [V] ≤ 1.1
Max. Output Drop at 0.4A [V] ≤ 1.6
EMC EN50081-1 / EN50082-2
Max. Tolerance Ambient Field Strength [A/m] <1200
Min. Distance to Next AC Solenoid [m] >0.1
Interface M12x1 per IEC 61076-2-101
Wiring Minimum [mm²] 5 x 0.25 brad shield recommended
Wiring Length Maximum [m] 50 (164 ft.) recommended
1 + Supply 18...42V
2 Out B: normally closed
3 0V
4 Out A: normally open
5 Earth ground
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end
signal at the moment (below 15% spool stroke) when position is reached. (above 85% spool stroke).
the spool leaves the spring offset position.
D41.indd, dd
The flow curve diagram shows the flow versus pressure drop curves for all spool types. The relevant curve number
A for each spool type, operating position and flow direction is given in the table below.
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
A
Series D4L valves are 5 chamber, directional control
valves and are available in 2 or 3-position styles. They
are operated by a hand lever which is directly con-
nected to the spool.
The hand lever can be located either on the A or B
side. Spring offset and detent designs are available.
Features
• Low force required to shift spool.
• Hardened spools provide long life.
• Low pressure drop design.
Specifications
General
Design Directional spool valve
Actuation Lever
Size NG16
Mounting interface DIN 24340 A16, ISO 4401, NFPA D07, CETOP RP 121-H
Mounting Position Unrestricted, preferably horizontal
Ambient Temperature [°C] -25...+50; (-13°F...+122°F)
Hydraulic
Maximum Operating Pressure External Drain: P, A B, T 350 Bar (5075 PSI); X, Y 10 Bar (145 PSI)
Internal Drain: P, A B 350 Bar (5075 PSI); T, X, Y 10 Bar (145 PSI)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid Temperature [°C] -25 ... +70; (-13°F...+158°F)
Viscosity Permitted [cSt] /[mm²/s] 2.8...400 (13...1854 SSU)
Recommended [cSt] /[mm²/s] 30...80 (139...371 SSU)
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Maximum Flow 300 LPM (79.4 GPM)
Leakage at 350 Bar (per flow path) [ml/min] up to 200 (0.05 GPM) (depending on spool)
D41.indd, dd
Code Description
2* External Pilot External Drain
Code Actuation
5** External Pilot Internal Drain
L Lever Side B * Pressure T-port > 10 bar
LB Lever Side A ** Pressure T-port < 10 bar
3 Position Spools
Code All 3 Position Spools
3 Position Spools 3 positions.
Code Spool Type C Spring offset in position “0”.
a 0 b Operated in position “a” or “b”.
1 Standard Spool Type 9
2
2 positions.
E
3 Spring offset in position “0”.
Operated in Operated in
4 position “a”. position “b”.
6
2 positions.
F
7 Spring offset in position “b”.
Operated in Operated in
9 position “0”. position “0”.
11
2 positions.
K
14 Spring offset in position “0”.
Operated in Operated in
15 position “b”. position “a”.
30 3 positions, detent.
N
No center in No center in offset Operated in position “a”, “0” or “b”.
offset position. position.
2 positions, detent.
R
No center in No center in Operated in position “0” or “b”.
offset position. offset position.
Weight: 9.0 kg (19.8 lbs.) 2 positions, detent.
S Operated in position “0” or “a”.
No center in No center in
No center in offset position.
offset position. offset position.
2 Position Spools
Code Spool Position
Spring offset in position “b”.
B
Operated in position “a”.
Detent, operated in position “a” or
D
“b”. No center or offset position.
Further spool types on request.
Spring offset in position “a”.
H
Operated in position “b”.
D41.indd, dd
D41.indd, dd
D4LB
D41.indd, dd
A
Series D4P directional control valves are 5-chamber
pilot operated valves. They are available in 2 or 3-posi-
tion styles. These manifod mounted valves conform to
NFPA’s D07, CETOP 7 and NG16.
Features
• Low pressure drop design.
• Hardened spools for long life.
Specifications
General
Design Directional spool valve
Actuation Hydraulic
Size NG16
Mounting interface DIN 24340 A16, ISO 4401, NFPA D07, CETOP RP 121-H
Mounting Position Unrestricted, preferably horizontal
Ambient Temperature [°C] -25...+50 (-13°F...+122°F)
MTTFD value 150 years
Hydraulic
Maximum Operating Pressure External Drain: P, A B, T 350 Bar (5075 PSI); X, Y 350 Bar (5075 PSI)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid Temperature [°C] -25 ... +70 (-13°F...+158°F)
Viscosity Permitted [cSt] /[mm²/s] 2.8...400 (13...1850 SSU)
Recommended [cSt] /[mm²/s] 30...80 (139...371 SSU)
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Maximum Flow 300 LPM (79.4 GPM)
Leakage at 350 Bar (per flow path) [ml/min] up to 200 (0.05 GPM) (depending on spool)
Pilot Supply Pressure Minimum 5 Bar (73 PSI)
Maximum 350 Bar (5075 PSI)
Static / Dynamic
The response times depend on the pilot oil pressure and on the speed of the increase/
Step Response
decrease of the pilot pressure.
D41.indd, dd
5
2 positions.
E
6 Spring offset in position “0”.
Operated in Operated in
position “a”. position “b”.
7
9 2 positions.
F
11 Spring offset in Spring offset in Operated in position “0”.
position “b”. position “a”.
14
15
2 positions.
K
16 Spring offset in position “0”.
Operated in Operated in
position “b”. position “a”.
21
22
2 positions.
M
54 Operated in position “0”.
Spring offset in Spring offset in
81 position “a”. position “b”.
82
2 positions, detent.
R
No center in No center in Operated in position “0” or “b”.
2 Position Spools offset position. offset position.
Code Spool Type
a b 2 positions, detent.
20 S Operated in position “0” or “a”.
No center in No center in No center in offset position.
26 offset position. offset position.
30
2 Position Spools
Code Spool Position
Spring offset in position “b”.
B
Operated in position “a”.
D41.indd, dd
D41.indd, dd
D41.indd, dd
D41.indd, dd
D41.indd, dd
Note: With * marked dimensions ±0.1 mm. All other dimensions ±0.2mm.
D41.indd, dd
Series D6 hydraulic directional control valves are high • Easy access mounting bolts.
A performance, solenoid controlled, pilot operated,
2-stage, 4-way valves. They are available in • 210 Bar (3000 PSI) pressure rating.
2 or 3-position styles. These valves are manifold • Flows to 380 LPM (100 GPM) depending on spool.
mounted, and conform to NFPA’s D08, CETOP 8
mounting patterns. • Choice of four operator styles.
Operation • Rugged four land spools.
Series D61 directional valves consist of a 5-chamber • Low pressure drop.
style main body, a case hardened sliding spool, and a
pilot valve or pilot operators (hydraulic or pneumatic). • Phosphate finish.
D61.indd, dd
D61.indd, dd
A Directional
Control Valve
Basic Valve Actuator Spool Style Pilot Supply
and Drain
Seal Solenoid
Voltage
P T
H* Single solenoid, 2 position, spring offset.
P T
A B P to B and A to T in offset position.
008* P T
009** A B a
* Available with 001, 002, 004, 011 and 014 spools only.
** High watt coil only.
Solenoid
Connection
Coil
Options
Tube
Options
Manual
Override
Options
Electrical
Options
Shift
Response
and Indication
Approvals Valve
Variations
Design
Series
NOTE:
A
Not required
when ordering.
Code Description Code Description
C* Leadwire Conduit Box Omit Standard
See next page
D** Metric Plug (M12X1), P Extended with Boot
DESINA T† None
E† Explosion Proof † DC or AC Rectified only. Code Description
G†† Plug-In Conduit Box Manual Override options Omit Standard Valve
J# Deutsch (DT06-2S) not available with Explosion
3*† CSA US
Proof.
M# Metri-Pack (150) 4*# CSA Approved
P DIN with Plug
* Not available with AC high
S# Dual Spade Code Description pressure tube.
W† DIN w/o Plug Omit Standard Pressure # Valve is derated with this
* No variations – See Plug-in. 103.5 Bar (1500 PSI) AC option.
** DC only, lights, diode surge 207 Bar (3000 PSI) DC † B, C, H styles only. J, K, Y, U
suppressor, not CSA approved. voltages only with C, G, W
H* High Pressure, AC only solenoid connections only.
† Not available with lights. 207 Bar (3000 PSI)
†† Required for variations on Conforms to UL429.
conduit box style. Must have * Not available with CSA.
lights.
# DC only, no lights, not CSA
approved.
D61.indd, dd
A
MaximumFlow, Maximum Flow,
LPM (GPM) LPM (GPM)
Spool 207 Bar (3000 PSI) Spool 207 Bar (3000 PSI)
Model Symbol w/o Malfunction Model Symbol w/o Malfunction
A B A B
D61V* Series Pressure Drop Chart D61VW Pressure Drop Reference Chart -- Curve Number
The following chart provides the flow vs. pressure drop Spool
No. P–A P–B P–T A–T B–T
curve reference for the Series D61V valves by spool
type. 001 3 3 – 1 2
002 4 4 5 4 5
003 3 3 – 4 2
VISCOSITY CORRECTION FACTOR
004 3 3 – 4 5
Viscosity (SSU) 75 150 200 250 300 350 400 005 3 4 – 1 2
% of ∆P (Approx.) 93 111 119 126 132 137 141 006 4 4 – 1 2
Curves were generated using 100 SSU hydraulic oil. For any other 007 4 4 7 1 5
viscosity, pressure drop will change as per chart.
008/009 3 3 7 4 6
011 3 3 – 1 2
012 3 3 8 4 5
014 4 4 – 2 1
015 3 3 – 2 4
016 4 3 – 2 1
Performance Curves
D61.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D61.indd, dd
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
D61.indd, dd
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
D61.indd, dd
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
D61.indd, dd
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
Hirschmann and Pilot Choke Control, Plug-in Conduit Box, Single DC Solenoid
Double DC Solenoid
D61.indd, dd
Monitor Switch
(Variation I3 and I6)
This feature provides for electrical confirmation of Position Control Switch
the spool shift. This can be used in safety circuits,
to assure proper sequencing, etc. Sensor / Driver
Circuitry
Switch Data PIN 2
Pin 1 and Pin 3 have outputs equal to the input. Input PIN 1
When the monitor switch has the output to Pin 1, 18-42 VDC Outputs
Pin 3 will have an output of zero, and vice-versa. PIN 3
When the valve is switched, Pin 1 and Pin 3 will
switch outputs. Load 0.2 A Max
D61.indd, dd
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
A B
A B
4# Int. pilot/Int. drain 89 Stroke Adj.
002 011 ‘A’ & ‘B’ Ends
P T
5 Ext. pilot/Int. drain
P T 90 1/4 BSPP Threads
A B
A B
# Not available with 002, 008
004 012 & 009 spools.
P T
P T
Code Description Symbol
* 008 spool has closed crossover. b A B
** 009 spool has open crossover. B Single operator, 2 position, spring offset.
P to A and B to T in offset position. b A
P
B
T
a
Valve schematic symbols are per NFPA/ C Double operator, 3 position, spring centered.
ANSI standards, providing flow P to A when P T
sides for #8 and #9 spools. See installation D Double operator, 2 position, detent.
P T
information for details. b A B
E Single operator, 2 position, spring offset to center.
Valve Weight: 12.4 kg (27.3 lbs.) P to B and A to T in shifted position. P T
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
D61.indd, dd
Specifications
Mounting Pattern NFPA D08, CETOP 8, NG25
Max. Operating 207 Bar (3000 PSI)
Pressure
Max. Tank Internal Drain Model:
Pressure 34 Bar (500 PSI)
External Drain Model:
207 Bar (3000 PSI)
Maximum Drain 34 Bar (500 PSI)
Pressure
Maximum Flow See Reference Data
Pilot Oil Min. 6.9 Bar (100 PSI)
Pressure Oil Max. 207 Bar (3000 PSI)
Varies with pilot line size and Features
Response Time
length, pilot pressure, pilot valve
shift time & flow capacity (GPM)
• Low force required to shift spool.
• Hardened spools provide long life.
Ordering Information • Low pressure drop design.
D 61V L
Directional Basic Lever Operated Spool Style Pilot Supply Seal Valve Design
Control Valve Pilot and Drain Variations Series
Valve NOTE:
NFPA D08 Code Description Code Description Code Description Not
CETOP 8 1 Int. pilot/Ext. drain N Nitrile Omit Standard required
2 Ext. pilot/Ext. drain V Fluorocarbon 7 Pilot Choke – when
Meter Out ordering.
4# Int. pilot/Int. drain
Code Symbol Code Symbol 8 Stroke Adj. ‘B’ End
5 Ext. pilot/Int. drain
A B A B 9 Stroke Adj. ‘A’ End
001 008* # Not available with 002, 008 60 Pilot Choke –
009** & 009 spools.
P T P T Meter In
A B
A B
89 Stroke Adj.
002 011 ‘A’ & ‘B’ Ends
P T P T
A B A B
Code Description Symbol
004 012 A B
P T P T
B* Single operator, 2 position, spring offset.
P to A and B to T in offset position. P T
* 008 spool has closed crossover. A B
** 009 spool has open crossover. C Double operator, 3 position, spring centered.
P T
D61.indd, dd
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
39.6
(1.56)
Pilot Choke
Control
Variation 7 183.6
(7.23)
Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve.
D61.indd, dd
Filtration
For maximum valve and system component life, the
system should be protected from contamination at
a level not to exceed 125 particles greater than 10
microns per milliliter of fluid (SAE class 4/ISO 16/13).
D61.indd, dd
D61.indd, dd
152.4
(6.00)
-B-
130.2
(5.13) 112.7
(4.44)
100.8
(3.97) 94.5
(3.72)
77.0
(3.03) ½ – 13 UNC – 2Bx22.22
53.2 min th'd dp. (M12 x 0.875)
(2.09) 6 holes
29.4 0.28
17.5 4.8 (1.16) A B
17.5 (0.011) S
(0.69) (0.19)
(0.69)
D61.indd, dd
D61.indd, dd
Series D81 hydraulic directional control valves are high • Easy access mounting bolts.
A performance, solenoid controlled, pilot operated,
2-stage, 4-way valves. They are available in 2 or • 345 Bar (5000 PSI) pressure rating.
3-position styles and are manifold mounted. These • Flows to 622 LPM (160 GPM) depending on spool.
valves conform to NFPA’s D08, CETOP 8 mounting
pattern. • Choice of four operator styles.
Operation • Rugged four land spools.
Series D81 directional valves consist of a 5-chamber • Low pressure drop.
style main body, a case hardened sliding spool, and a
pilot valve or pilot operators (hydraulic or pneumatic). • Phosphate finish.
D81.indd, dd
Operation
Series D81VW pilot operated valves are standard with
low shock spools and pilot orifice. The orifice can be
removed if a faster shift is required. It is recommended,
however, that all systems operating above 138 Bar
(2000 PSI) use the standard valve to avoid severe
shock.
Features
• Low pressure drop design.
• Hardened spools provide long life.
• Fast response option available.
• Wide variety of voltages and electrical connection options.
• Explosion proof availability.
• No tools required for coil removal.
Response Time
Specifications
Response times (milliseconds) are measured at
Mounting Pattern NFPA D08, 345 Bar (5000 PSI) and 300 LPM (80 GPM) with
CETOP 8, NG25
various pilot pressures as indicated.
Maximum Operating 345 Bar (5000 PSI) Standard
Pressure 207 Bar (3000 PSI) 10 Watt Solenoid Pilot Pull-In Drop-Out
Type Pressure Std Fast Std Fast
CSA 207 Bar (3000 PSI)
Maximum Tank Line Internal Drain Model: 500 140 100 70 70
Pressure 103 Bar (1500 PSI) AC Only DC 1000 125 90 76 76
207 Bar (3000 PSI) DC Std., 2000 100 70 70 70
AC Optional
500 100 60 60 60
External Drain Model: AC 1000 85 50 60 60
345 Bar (5000 PSI)
2000 60 30 60 60
CSA 103 Bar (1500 PSI)
Because of the high drain line pressure transients gen-
Maximum Drain 103 Bar (1500 PSI) AC Only erated during shifting, use of the fast response option
Pressure 207 Bar (3000 PSI) DC Std.,
AC Optional is not recommended for pilot pressures exceeding 138
Bar (2000 PSI).
CSA 103 Bar (1500 PSI)
Minimum Pilot 5.1 Bar* (75 PSI)
Pressure
Maximum Pilot 345 Bar (5000 PSI) Standard
Pressure CSA 207 Bar (3000 PSI)
Nominal Flow 302 LPM (80 GPM)
* 6.9 Bar (100 PSI) for spool configurations 002, 007, 008, 009 & 014.
D81.indd, dd
A Directional
Control Valve
Basic Valve Actuator Spool Style Pilot Supply
and Drain
Seal Solenoid
Voltage
Code Description
NFPA D08
N Nitrile
CETOP 8
DIN NG25 V Fluorocarbon
High Flow, D03 Pilot
Code Description
A* 24/50 VAC
Code Description Code Description D 120 VDC
W* Solenoid, Wet Pin, 1 Internal Pilot, G 198 VDC
Screw-in External Drain J 24 VDC
HW* Reversed Wiring 2 External Pilot, K 12 VDC
External Drain
* Valve schematic symbols are per NFPA/ N** 220/50 VAC
ANSI standards, providing flow P to 3 Internal Pilot w/Check,
Q* 100/60 VAC
A when energizing solenoid A. Note External Drain
QD† 100 VAC/60 Hz
operators reverse sides for #008 and 4* Internal Pilot,
100 VAC/50 Hz
#009 spools. See installation information Internal Drain
for details. To configure per DIN R 24/60 VAC
5 External Pilot,
standards (A coil over A port, B coil over Internal Drain T 240/60 - 220/50 VAC
B port) code valves as D81VHW***. 6 Internal Pilot w/Check, U 98 VDC
Internal Drain Y 120/60 - 110/50 VAC
* Not availble with 002, 007, Z 250 VDC
Code Symbol Code Symbol 008, 009, 014 & 030 spools. * High Watt Coil only.
A B A B
** Explosion Proof only.
001 012
† Available in DIN only.
P T P T
A B A B Code Description Symbol
002 014 b A B
P T P T
A B
C Double solenoid, 3 position, spring centered.
A B
004 016 P T
b A B a
P
A
T
B
P T
D* Double solenoid, 2 position, detent.
A B
005 020* P T
b A B
P T
P T E Single solenoid, 2 position, spring centered.
006 A B
030** A B P to B and A to T when energized.
P T
b A B
P T P T F** Single solenoid, 2 position, spring offset,
A B
007 081 A B
energized to center. Position spool spacer on
A side. P to A and B to T in spring offset position. P T
P T P T
A B A B a
008* 082 A B
H* Single solenoid, 2 position, spring offset.
009** P to B and A to T in offset position.
P T P T P T
A B A B a
011 K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
P T P T
A B a
* 008 & 020 spool have closed crossover. M** Single solenoid, 2 position, spring offset,
** 009 & 030 spool have open crossover. energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position. P T
A
Solenoid Coil Tube Manual Electrical Shift Approvals Valve Design
Connection Options Options Override Options Response Variations Series
Options and Indication NOTE:
Not required
when
Code Description Code Description ordering.
C* Leadwire Conduit Box Omit Standard Response,
D** Metric Plug (M12X1), No Switch See next page
DESINA I3 Monitor Switch,
E† Explosion Proof ‘A’ & ‘B’ Port End
G†† Plug-In Conduit Box I6 Monitor Switch,
‘A’ & ‘B’ Port Start
J# Deutsch (DT06-2S)
Note: Not CE or CSA approved.
M# Metri-Pack (150)
Not available with ‘F’ or ‘M’
P DIN with Plug styles.
S# Dual Spade
W† DIN w/o Plug
Code Description
* No variations – See Plug-in.
Omit No Options
** DC only, lights, diode surge
suppressor, not CSA approved. J* Diode Surge
† Not available with lights. Suppressor
Z† Rectified Coil Code Description
†† Required for variations on
conduit box style. Must have Omit Standard Valve
* DC only.
lights. 3*† CSA US
DIN coil must include
# DC only, no lights, not CSA 4*# CSA Approved
plug with lights.
approved.
† DC tube standard. * Not available with AC high
pressure tube.
# Valve is derated with this
Code Description option.
Code Description Omit Standard † B, C, H styles only. J, K, Y, U
Omit* High Watt voltages only with C, G, W
P Extended
D** Explosion Proof, solenoid connections only.
with Boot
EEXD ATEX Conforms to UL429.
T† None
E** Explosion Proof,
EEXME ATEX † DC or AC Rectified only.
Manual Override options Valve Weight:
F† Low Watt not available with Explosion Double Solenoid 19.6 kg (43.2 lbs.)
L†† 10 Watt Proof. Seal Kit:
O** Explosion Proof, Nitrile SKD81VWN91
MSHA Fluorocarbon SKD81VWV91
T# Explosion Proof,
Ex d IIC ATEX/CSA Code Description Mounting Bolt Kits
U** Explosion Proof, Omit Standard Pressure UNC Bolt Kits for use with D6 and D8
UL/CSA 103 Bar (1500 PSI) AC Directional Control Valves & Sandwich Valves
* AC ambient temperature must 207 Bar (3000 PSI) DC Number of Sandwich Valves
not exceed 60°C (140°F). H* High Pressure, AC only @ 2.75" (70mm) thickness
** 60 Hz only on AC, no options. 207 Bar (3000 PSI)
0 1 2 3
† AC only.
* Not available with CSA. D6 BK227 BK121 BK122 BK123
†† DC and AC rectified only.
# J, K and Y voltages only. Dual 2.50" 5.25" 8.00" 10.75"
frequency on AC, no options. D6 plus BK161 BK170 BK171 BK172
tapping plate 3.50" 6.25" 9.00" 11.75"
D8 BK228 BK131 BK132 BK133
3.00" 5.75" 8.50" 11.25"
D8 plus BK173 BK174 BK175 BK114
tapping plate 4.00" 6.75" 9.50" 12.125"
D81.indd, dd
A
MaximumFlow, Maximum Flow,
LPM (GPM) LPM (GPM)
Spool 345 Bar (5000 PSI) Spool 345 Bar (5000 PSI)
Model Symbol w/o Malfunction Model Symbol w/o Malfunction
A B A B
D81V*008
D81V*001 624 (160) 312 (80)
D81V*009
P T P T
A B A B
D81V*006 624 (160) D81V*016 624 (160)
P T P T
A B A B
D81V*020
D81V*007 312 (80) 624 (160)
P T D81V*030 P T
D81.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D81.indd, dd
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
D81.indd, dd
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
Conduit Box and Pilot Choke Control, Conduit Box, Single AC Solenoid
Double AC Solenoid
D81.indd, dd
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
D81.indd, dd
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
D81.indd, dd
Monitor Switch
(Variation I3 and I6)
Position Control Switch
This feature provides for electrical confirmation of
the spool shift. This can be used in safety circuits, Sensor / Driver
to assure proper sequencing, etc. Circuitry
PIN 2
Switch Data Input PIN 1
Pin 1 and Pin 3 have outputs equal to the input. 18-42 VDC Outputs
When the monitor switch has the output to Pin 1, PIN 3
Pin 3 will have an output of zero, and vice-versa.
When the valve is switched, Pin 1 and Pin 3 will Load 0.2 A Max
switch outputs.
D81.indd, dd
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
Air Operated
A
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
D81.indd, dd
002 012 # Not available with 002, 008, 89 Stroke Adj. ‘A’ & ‘B’
P T P T 009 & 030 spools.
A B A B
P T P
A
T
B
B† Sgl. operator, 2 position, spring offset.
A B
008* 030** P to A and B to T in offset position. P T
A B
009** P T P T C Dbl. operator, 3 position, spring centered.
* 008 & 020 spools have closed crossover. A
P
B
T
** 009 & 030 spools have open crossover. D† Dbl. operator, 2 position, detent.
P T
Valve schematic symbols are per NFPA/ANSI A B
standards, providing flow P to A when energizing E Sgl. operator, 2 position, spring centered.
operator A. Note operators reverse sides for #9 P to B and A to T in shifted position. P T
A B
spool. See installation information for details. H† Sgl. operator, 2 position, spring offset. P to B
and A to T in offset position. P T
A B This condi-
Valve Weight: 19.6 kg (43.2 lbs.) K Sgl. operator, 2 position. Spring centered. tion varies
Standard Bolt Kit: BK228 P to A and B to T in shifted position. P T with spool
code.
Metric Bolt Kit: BKM228 † Available with 020 & 030 spools only.
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
D81.indd, dd
Lever Operated
A
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
D81.indd, dd
Features
• Low pressure drop design.
• Hardened spools provide long life.
Specifications
Mounting Pattern NFPA D08,
CETOP 8, NG25
Max. Operating Pressure 345 Bar (5000 PSI)
Max. Tank Line Pressure 345 Bar (5000 PSI)
Max. Drain Pressure 345 Bar (5000 PSI)
Min. Pilot Pressure 5.1 Bar* (75 PSI)
Max. Pilot Pressure 345 Bar (5000 PSI)
Nominal Flow 302 LPM (80 GPM) Response Time
Max. Flow See Reference Data Chart Response time will vary with pilot line size, pilot line
* 6.9 Bar (100 PSI) for 2, 8, 9 & 12 spools length, pilot pressure shift time and flow capacity of the
control valve.
For flow path, pilot drain and pilot pressure details, see Installation
Information. Shift Volume
The pilot chamber requires a volume of 1.35 in3
Ordering Information (22.1 cc) for center to end.
D 8 P
Directional Basic Actuator Spool Style Pilot Supply Seal Valve Design
Control Valve Valve and Drain Variations Series
NFPA D08 Oil Code Type Code Description NOTE:
CETOP 8 Operator Not
N Nitrile Omit Standard required
DIN NG25 7 Pilot Choke –
V Fluorocarbon when
Code Symbol Code Symbol Meter Out ordering.
Code Description 8 Stroke Adj. ‘B’ End
A B A B
2 Ext. Pilot / Ext. Drain 9 Stroke Adj. ‘A’ End
1 11
P T P T 5# Ext. Pilot / Int. Drain 60 Pilot Choke –
A B A B Meter In
# Available in “B” and “H” style only.
2 12 89 Stroke Adj. ‘A’ & ‘B’ Ends
P T P T
A B A B
Code Description Symbol
4 20*
P T P T B† Sgl. operator, 2 position, spring offset.
A B A B
P to A and B to T in offset position.
7 30**
P T P T C Dbl. operator, 3 position, spring centered.
A B
39.6
(1.56)
Pilot Choke
Control
Variation 7 212.4
(8.37)
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
D81.indd, dd
Silting
FOR MAXIMUM VALVE RELIABILITY, ADHERE TO
THE FOLLOWING INSTALLATION INFORMATION.
Silting can cause any sliding spool valve to stick
and not spring return if held under pressure for long
A
periods of time. The valve should be cycled periodically
The following is important installation information to prevent sticking.
which applies to all directional control valves
described in this catalog.
Special Installations
Consult your Parker representative for any application
Mounting Position requiring the following:
Detent – Horizontal
Spring Offset – Unrestricted • Pressure above rating.
Spring Centered – Unrestricted • Fluid other than those specified.
• Oil temperature above 71.1°C (160°F).
Fluid Recommendations • Flow path other than normal.
Premium quality hydraulic oil with a viscosity range
between 32-54 cSt. (150-250 SSU) At 38°C (100°F) is
recommended. The absolute operating viscosity range Mounting Patterns
is from 16-220 cSt. (80-1000 SSU). Oil should have
maximum anti-wear properties and rust and oxidation Series NFPA CETOP
treatment. D81V*, D8P D08 3/4”
Filtration
For maximum valve and system component life, the
system should be protected from contamination at
a level not to exceed 125 particles greater than 10
microns per milliliter of fluid (SAE class 4/ISO 16/13).
D81.indd, dd
D81.indd, dd
152.4
(6.00)
-B-
130.2
(5.13) 112.7
(4.44)
100.8
(3.97) 94.5
(3.72)
77.0
(3.03) ½ – 13 UNC – 2Bx22.22
53.2 min th'd dp. (M12 x 0.875)
(2.09) 6 holes
29.4 0.28
17.5 4.8 (1.16) A B
17.5 (0.011) S
(0.69) (0.19)
(0.69)
D81.indd, dd
Features
• Streamlined internal channels ensure minimum pressure
drop at maximum flow.
• Hardened spools provide long life.
Specifications
General Hydraulic (cont.)
Actuation Lever Fluid Hydraulic oil in accordance with
Size NG25 DIN 51524 / 51525
Mounting Interface DIN 24340 A25 Fluid Temperature -25°C to +70°C (-13°F to +158°F)
ISO 4401 Viscosity 2.8 to 400 cSt / mm2/s
NFPA D08 Permitted (13 to 1854 SSU)
CETOP RP 121-H Viscosity 30 to 80 cSt / mm2/s
Mounting Position Unrestricted, preferably horizontal Recommended (139 to 371 SSU)
Ambient Temperature -25°C to +50°C (-13°F to +122°F) Filtration ISO 4406 (1999);
Hydraulic 18/16/13 (meet NAS 1638: 7)
Maximum Operating External Drain Maximum Flow 700 LPM (185.2 GPM)
Pressure P, A, B, T 350 Bar (5075 PSI) Leakage at up to 800 ml per minute
X, Y 10 Bar (145 PSI) 350 Bar (5075 PSI) (per flow path) (depending on spool)
Internal Drain
P, A, B 350 Bar (5075 PSI)
T, X, Y 10 Bar (145 PSI)
D81.indd, dd
A Directional
Control
Valve
Basic
Valve
Actuator Spool Style Pilot Supply
and Drain
Seal Design
Series
NOTE:
Not required
NFPA D08 when ordering.
CETOP 8
DIN NG25 Code Description
32 mm N Nitrile
V Fluorocarbon
Code Description
Code Actuation
2* External Pilot External Drain
L Lever Side B
5** External Pilot Internal Drain
LB Lever Side A
* Pressure T-port < 10 bar
** Pressure T-port > 10 bar
A B A B Double operator,
C 3 position,
02 14
spring centered.
P T P T
Double operator,
A B A B
D 2 position,
03 15 detent.
P T P T
Single operator,
A B A B E 2 position,
04 20 spring centered.
P T P T Single operator,
A B A B H 2 position,
spring offset.
07 30
P T P T Single operator,
K 2 position,
spring centered.
Double operator,
N 3 position,
detent.
D81.indd, dd
D81.indd, dd
D9LB
D81.indd, dd
D81.indd, dd
Series D101 hydraulic directional control valves are • Easy access mounting bolts.
A high performance, solenoid controlled, pilot operated,
2-stage, 4-way valves. They are available in 2 or
• 210 Bar (3000 PSI) pressure rating.
3-position styles and are manifold mounted. These • Flows to 950 LPM (250 GPM) depending on spool.
valves conform to NFPA’s D10, CETOP 10 mounting
pattern.
• Choice of four operator styles.
Operation
• Rugged four land spools.
Series D101 directional valves consist of a 5-chamber
• Low pressure drop.
style main body, a case hardened sliding spool, and a • Phosphate finish.
pilot valve or pilot operators (hydraulic or pneumatic).
D101.indd, dd
D101.indd, dd
A Directional
Control Valve
Basic Valve Actuator Spool Style Pilot Supply
and Drain
Seal Solenoid
Voltage
A B a
H* Single solenoid, 2 position, spring offset.
P to B and A to T in offset position.
P T
A B a
K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
P T
A B a
M Single solenoid, 2 position, spring offset,
energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position. P T
Solenoid
Connection
Coil
Options
Tube
Options
Manual
Override
Options
Electrical
Options
Shift
Response
and Indication
Approvals Valve
Variations
Design
Series
NOTE:
A
Not required
when ordering.
Code Description Code Description
C* Leadwire Conduit Box Omit Standard
D** Metric Plug (M12X1), P Extended See next page
DESINA with Boot
E† Explosion Proof T* None
G†† Plug-In Conduit Box * DC or AC Rectified only. Code Description
J# Deutsch (DT06-2S) Manual Override options Omit Standard Valve
M# Metri-Pack (150) not available with 3*† CSA USA (UL 429)
Explosion Proof. 4*# CSA Approved
P DIN with Plug
S# Dual Spade * Not available with AC high
pressure tube.
W† DIN w/o Plug Code Description
† B, C, H styles only. J, K, Y, U
* No variations – See Plug-in. Omit Standard Pressure voltages only with C, G, W
** DC only, lights, diode surge 103.5 Bar (1500 PSI) AC solenoid connections only.
suppressor, not CSA approved. 207 Bar (3000 PSI) DC Conforms to UL429.
† Not available with lights. H* High Pressure, AC only # Valve is derated.
†† Required for variations on 207 Bar (3000 PSI)
conduit box style. Must have * Not available with CSA. Code Description
lights.
# DC only, no lights, not CSA Omit Standard Response,
approved. No Switch
I3 Monitor Switch,
‘A’ & ‘B’ Port End
Code Description
I6 Monitor Switch,
Omit* High Watt
‘A’ & ‘B’ Port Start
D** Explosion Proof,
Note: Not CE or CSA approved.
EEXD ATEX
Not available with ‘F’ or ‘M’
E** Explosion Proof, styles.
EEXME ATEX
F† Low Watt
L†† 10 Watt Code Description
O** Explosion Proof, Omit No Options
MSHA J* Diode Surge
T# Explosion Proof, Suppressor
Ex d IIC ATEX/CSA Z† Rectified Coil
U** Explosion Proof, * DC only.
UL/CSA DIN coil must include plug
* AC ambient temperature must with lights.
not exceed 60°C (140°F). † DC tube standard.
** 60 Hz only on AC, no options.
† AC only.
†† DC and AC rectified only.
# J, K and Y voltages only. Dual
frequency on AC, no options.
Valve Weight:
Double Solenoid 35.0 kg (77.1 lbs.)
Standard Bolt Kit: BK229
Seal Kit:
Nitrile SKD101VWN91
Fluorocarbon SKD101VWV91
A
MaximumFlow, Maximum Flow,
LPM (GPM) LPM (GPM)
Spool 205 Bar (3000 PSI) Spool 205 Bar (3000 PSI)
Model Symbol w/o Malfunction Model Symbol w/o Malfunction
A B A B
Performance Curves
PSI Bar
7 6
350
22.5
5
300
20
250 17.5 4
Pressure Drop
15 3
200
12.5
2
150 10
1
7.5
100
5
50
2.5
0
LPM 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 945
0
GPM 25 50 75 100 125 150 175 200 225 250
Flow
D101.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D101.indd, dd
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.
D101.indd, dd
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.
Conduit Box and Pilot Choke Control, Conduit Box, Single AC Solenoid
Double AC Solenoid
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.
D101.indd, dd
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.
Hirschmann and Pilot Choke Control, Plug-in Conduit Box, Single DC Solenoid
Double DC Solenoid
Monitor Switch
(Variation I3 and I6)
This feature provides for electrical confirmation of Position Control Switch
the spool shift. This can be used in safety circuits,
to assure proper sequencing, etc. Sensor / Driver
Circuitry
Switch Data
Pin 1 and Pin 3 have outputs equal to the input. PIN 2
Input PIN 1
When the monitor switch has the output to Pin 1, 18-42 VDC Outputs
Pin 3 will have an output of zero, and vice-versa.
PIN 3
When the valve is switched, Pin 1 and Pin 3 will
switch outputs. Load 0.2 A Max
D101.indd, dd
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
A
Series D101VA directional control valves are 5-chamber,
air pilot operated valves. They are available in 2 or
3-position styles. These valves are manifold or subplate
mounted, and conform to NFPA’s D10, CETOP 10
mounting pattern.
Specifications
Mounting Pattern NFPA D10, CETOP 10, NG32
Max. Operating 207 Bar (3000 PSI)
Pressure
Max. Tank Internal Drain Model:
Pressure 34 Bar (500 PSI)
External Drain Model:
207 Bar (3000 PSI)
Max. Drain Pressure 34 Bar (500 PSI)
Maximum Flow See Reference Chart
Pilot Pressure Air Min 3.4 Bar (50 PSI)
Air Max 10.2 Bar (150 PSI)
Response Time Varies with pilot line size and Features
length, pilot pressure, pilot valve
shift time & flow capacity (GPM) • Low pressure drop design.
• Hardened spools provide long life.
Ordering Information
D 101V A
Directional Basic Air Operated Spool Style Pilot Supply Seal Valve Design
Control Valve Valve Pilot and Drain Variations Series
NOTE:
NFPA D10 Code Type Not required
CETOP 10 N Nitrile when ordering.
V Fluorocarbon Code Description
Valve schematic Omit Standard
Code Symbol
symbols are Code Description 7 Pilot Choke – Meter Out
A B
per NFPA/ANSI 1 Int. pilot/Ext. drain 8 Stroke Adj. ‘B’ End
standards, providing 1
P T 2 Ext. pilot/Ext. drain 9 Stroke Adj. ‘A’ End
flow P to A when A B
4# Int. pilot/Int. drain 60 Pilot Choke – Meter In
energizing operator 2
A. Note operators P T 5 Ext. pilot/Int. drain 89 Stroke Adj. ‘A’ & ‘B’ Ends
reverse sides on A B
# Not available with 2, 8 & 9 spools. 90 1/4 BSPP Threads
#8 and #9 spools. 4
See installation P
A
T
B Code Description Symbol
information for 8* b A B
Air Operated
A
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.
D101.indd, dd
Specifications
Mounting Pattern NFPA D10, CETOP 10, NG32
Max. Operating 207 Bar (3000 PSI)
Pressure
Max. Tank Internal Drain Model:
Pressure 34 Bar (500 PSI)
External Drain Model:
207 Bar (3000 PSI)
Max. Drain Pressure 34 Bar (500 PSI)
Maximum Flow See Reference Chart
Pilot Pressure Oil Min 6.9 Bar (100 PSI)
Oil Max 207 Bar (300 PSI)
Response Time Varies with pilot line size and Features
length, pilot pressure, pilot valve
shift time & flow capacity (GPM) • Low force required to shift spool.
• Hardened spools provide long life.
Ordering Information • Low pressure drop design.
D 101V L
Directional Basic Lever Operated Spool Style Pilot Supply Seal Valve Design
Control Valve Valve Pilot and Drain Variations Series
NOTE:
NFPA D10 Code Type Code Description Not
CETOP 10 N Nitrile Omit Standard required
when
V Fluorocarbon 7 Pilot Choke –
ordering.
Code Symbol Meter Out
A B
Code Supply — Drain 8 Stroke Adj. ‘B’ End
1 1 Int. pilot/Ext. drain 9 Stroke Adj. ‘A’ End
P
A
T
B
2 Ext. pilot/Ext. drain 60 Pilot Choke –
2 4# Int. pilot/Int. drain Meter In
P T 5 Ext. pilot/Int. drain 89 Stroke Adj.
A B ‘A’ & ‘B’ Ends
4 # Not available with 2, 8
P T
& 9 spools.
A B
Bold: Designates Tier I products and options. Valve Weight: 35.0 kg (77.2 lbs.)
Standard Bolt Kit: BK229
Non-Bold: Designates Tier II products and options.
Metric Bolt Kit: BKM229
These products will have longer lead times.
D101.indd, dd
Lever Operated
A
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.
D101.indd, dd
D 10 P
Directional Basic Valve Actuator Spool Style Pilot Supply Seal Valve Design
Control Valve and Drain Variations Series
Oil NOTE:
NFPA D10 Code Symbol Code Description
Code Type Not
CETOP 10 Operator A B
N Nitrile Omit Standard required
1 when
V Fluorocarbon 7 Pilot Choke –
P
A
T
B Meter Out ordering.
2 Code Description 8 Stroke Adj. ‘B’ End
P T 2 Ext. Pilot / Ext. Drain 9 Stroke Adj. ‘A’ End
A B
5# Ext. Pilot / Int. Drain 60 Pilot Choke –
4
P T
# Available in “B” & “H” styles only. Meter In
Valve schematic symbols A B
8* 89 Stroke Adj.
are per NFPA/ANSI
‘A’ & ‘B’ Ends
standards, providing 9** P T
A B
flow P to A when
Code Description Symbol
energizing operator X. 11
P T
Note operators reverse B† Sgl. operator, 2 position, spring offset.
sides on #8 and #9 * 8 spool has closed P to A and B to T in offset position.
spools. See installation crossover.
** 9 spool has open C Dbl. operator, 3 position, spring centered.
information for details.
crossover.
H† Sgl. operator, 2 position, spring offset.
Valve Weight: 34.3 kg (75.7 lbs.) P to B and A to T in offset position.
Standard Bolt Kit: BK229 † Available with 1, 2, 4 & 11 spools only. This condition varies
Metric Bolt Kit: BKM229 with spool code.
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
D101.indd, dd
D101.indd, dd
Filtration
For maximum valve and system component life, the
system should be protected from contamination at
a level not to exceed 125 particles greater than 10
microns per milliliter of fluid (SAE class 4/ISO 16/13).
D101.indd, dd
D101.indd, dd
D101.indd, dd
Features
• Low pressure drop design.
• Hardened spools provide long life.
• Wide variety of voltages and electrical connection options.
• Explosion proof availability.
• No tools required for coil removal.
Performance Curves
The flow curve diagram shows the flow versus pres-
sure drop curves for all spool types. The relevant curve
number for each spool type, operating position and
Spool Curve Number
flow direction is given in the table below. Code P-A P-B P-T A-T B-T
001 5 5 – 4 1
002 5 5 5 4 1
009 3 3 2 3 1
020 5 5 – 3 1
030 5 5 – 4 1
054 5 5 – 4 1
D111VW.indd, dd
A Directional
Control Valve
Basic
Valve
Actuator Spool Style Pilot Supply
and Drain
009 2 positions.
E
Spring offset in position “0”.
054 Operated in Operated in
position “a”. position “b”.
081
2 positions.
082 F
Operated in position “0”.
Spring offset in Spring offset in
position “b”. position “a”.
2-Position Spools
Code Spool Type 2 positions.
K
a b Operated in Spring offset in position “0”.
Operated in
position “b”. position “a”.
020
030 2 positions.
M
Operated in position “0”.
Spring offset in Spring offset in
position “a”. position “b”.
2-Position Spools
Code Spool Position
Spring offset in position “b”.
B
Operated in position “a”.
Weight:
Single Solenoid: 67.4 kg (148.6 lbs.)
Double Solenoid: 68.0 kg (149.9 lbs.)
D111VW.indd, dd
Code
Voltage In Rush Amps In Rush Holding Amps Watts Resistance
Voltage Power Amperage VA @ 3MM
Code Code
D L 120 VDC N/A N/A 0.09 Amps 10 W 1584.00 ohms
D Omit 120 VDC N/A N/A 0.26 Amps 30 W 528.00 ohms
G Omit 198 VDC N/A N/A 0.15 Amps 30 W 1306.80 ohms
J L 24 VDC N/A N/A 0.44 Amps 10 W 51.89 ohms
J Omit 24 VDC N/A N/A 1.32 Amps 30 W 17.27 ohms
K L 12 VDC N/A N/A 0.88 Amps 10 W 12.97 ohms
K Omit 12 VDC N/A N/A 2.64 Amps 30 W 4.32 ohms
L L 6 VDC N/A N/A 1.67 Amps 10 W 3.59 ohms
L Omit 6 VDC N/A N/A 5.00 Amps 30 W 1.20 ohms
Q Omit 100 VAC / 60 Hz 2.05 Amps 170 VA 0.77 Amps 30 W 19.24 ohms
QD F 100 VAC / 60 Hz 1.35 Amps 135 VA 0.41 Amps 18 W 31.20 ohms
QD F 100 VAC / 50 Hz 1.50 Amps 150 VA 0.57 Amps 24 W 31.20 ohms
R F 24/60 VAC, Low Watt 6.67 Amps 160 VA 2.20 Amps 23 W 1.52 ohms
T Omit 240/60 VAC 0.83 Amps 199 VA 0.30 Amps 30 W 120.40 ohms
T Omit 220/50 VAC 0.87 Amps 191 VA 0.34 Amps 30 W 120.40 ohms
T F 240/60 VAC, Low Watt 0.70 Amps 168 VA 0.22 Amps 21 W 145.00 ohms
T F 220/50 VAC, Low Watt 0.75 Amps 165 VA 0.26 Amps 23 W 145.00 ohms
U L 98 VDC N/A N/A 0.10 Amps 10 W 960.00 ohms
U Omit 98 VDC N/A N/A 0.31 Amps 30W 288.00 ohms
Y Omit 120/60 VAC 1.7 Amps 204 VA 0.60 Amps 30 W 28.20 ohms
Y Omit 110/50 VAC 1.7 Amps 187 VA 0.68 Amps 30 W 28.20 ohms
Y F 120/60 VAC, Low Watt 1.40 Amps 168 VA 0.42 Amps 21 W 36.50 ohms
Y F 110/50 VAC, Low Watt 1.50 Amps 165 VA 0.50 Amps 23 W 36.50 ohms
Z L 250 VDC N/A N/A 0.04 Amps 10 W 6875.00 ohms
Z Omit 250 VDC N/A N/A 0.13 Amps 30 W 1889.64 ohms
Explosion Proof Solenoids
R 24/60 VAC 7.63 Amps 183 VA 2.85 Amps 27 W 1.99 ohms
T 240/60 VAC 0.76 Amps 183 VA 0.29 Amps 27 W 1.34 ohms
N 220/50 VAC 0.77 Amps 169 VA 0.31 Amps 27 W 1.38 ohms
Y 120/60 VAC 1.60 Amps 192 VA 0.58 Amps 27 W 33.50 ohms
P 110/50 VAC 1.47 Amps 162 VA 0.57 Amps 27 W 34.70 ohms
K 12 VDC N/A N/A 2.75 Amps 33 W 4.36 ohms
J 24 VDC N/A N/A 1.38 Amps 33 W 17.33 ohms
"ET" Explosion Proof Solenoids
K 12 VDC N/A N/A 1.00 Amps 12 W 12.00 ohms
J 24 VDC N/A N/A 1.00 Amps 13 W 44.30 ohms
Y 120/60-50 VAC N/A N/A 0.16 Amps 17 W 667.00 ohms
D111VW.indd, dd
A Actuation
Size
Solenoid
NG32
Mounting Interface DIN 24340 A32 / ISO 4401 / NFPA D10 / CETOP RP 121-H
Mounting Position Unrestricted, preferably horizontal
[°C] -25...+50; (-13°F...+122°F) (without inductive position control)
Ambient Temperature
[°C] 0...+50; (+32°F...+122°F) (with inductive position control)
MTTFD Value [years] 75
Hydraulic
Pilot drain internal: P, A, B, X 350 Bar (5075 PSI)
T, Y 102 Bar (1500 PSI) AC only, 207 Bar (3000 PSI) DC/AC optional
Maximum Operating Pressure
Pilot drain external: P, A, B, T, X 350 Bar (5075 PSI)
Y 102 Bar (1500 PSI) AC only, 207 Bar (3000 PSI) DC/AC optional
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid Temperature [°C] -25 ... +70; (-13°F...+158°F)
Viscosity Permitted [cSt] /[mm²/s] 2.8...400 (13...1854 SSU)
Recommended [cSt]/[mm²/s] 30...80 (139...371 SSU)
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow Maximum 2000 LPM (529.1 GPM)
Leakage at 350 Bar (per flow path) [ml/min] up to 5000 (1.32 GPM) depending on spool
Minimum Pilot Supply Pressure 5 Bar (73 PSI)
Static / Dynamic
Step Response at 95% Energized De-energized
DC Solenoids Pilot Pressure
50 Bar [ms] 470 390
100 Bar [ms] 320 390
250 Bar [ms] 210 390
350 Bar [ms] 200 390
AC Solenoids Pilot Pressure [ms]
50 Bar [ms] 450 375
100 Bar [ms] 300 375
250 Bar [ms] 190 375
350 Bar [ms] 180 375
D111VW.indd, dd
A
Protection Class IP 65 in accordance with EN 60529 (plugged and mounted)
Ambient Temperature [°C] 0...+50; (+32°F...122°F)
Supply Voltage / Ripple [V] 18...42 ±10%
Current Consumption without Load [mA] ≤ 30
Max. Output Current per Channel,
[mA] 400
Ohmic
Min. Output Load per Channel, Ohmic [kOhm] 100
Max. Output Drop at 0.2A [V] ≤ 1.1
Max. Output Drop at 0.4A [V] ≤ 1.6
EMC EN50081-1 / EN50082-2
Max. Tolerance Ambient Field Strength [A/m] <1200
Min. Distance to Next AC Solenoid [m] >0.1
Interface M12x1 per IEC 61076-2-101
Wiring Minimum [mm²] 5 x 0.25 brad shield recommended
Wiring Length Maximum [m] 50 (164 ft.) recommended
1 + Supply 18...42V
2 Out B: normally closed
3 0V
4 Out A: normally open
5 Earth ground
Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end
signal at the moment (below 15% spool stroke) when position is reached. (above 85% spool stroke).
the spool leaves the spring offset position.
D111VW.indd, dd
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
* Please add for each sandwich plate +40mm (1.58") (pressure reducing valve, pilot choke meter-in/-out).
The space necessary to remove the plug per DIN 43650, design type AF is at least 15 mm (0.59 in.).
The torque for the screw M3 of the plug has to be 0.5 Nm (3.7 lb.-ft. ) to 0.6 Nm (4.4 lb.-ft).
D111VW.indd, dd
Solenoid (Negative)
Solenoid (Positive)
Wire #3 (Red/Black)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves – Installed Opposite Side of Solenoid
Filtration
For maximum valve and system component life, the
system should be protected from contamination at
a level not to exceed 125 particles greater than 10
microns per milliliter of fluid (SAE class 4/ISO 16/13).
D111VW.indd, dd
D111VW.indd, dd
D111VW.indd, dd
A
Series D4S seat valves are designed for directional
control functions. A large variety of poppets, springs
and covers - including shuttle valves, stroke limiters,
solenoid valves (VV01) and position control - allow to
design individual hydraulic solutions for nominal flow
up to 600 LPM (158.7 GPM).
A complete program is offered under the Parker brand:
subplate mounted valves (D4S ), SAE flange valves
(D5S), pipe mounted valves (D4S), slip-in
cartridges (CAR - on request).
Features
• Subplate mounting acc. to ISO 5781.
• Leak-free seat valve design.
• Numerous pilot options.
• 6 poppet types.
• 3 sizes (NG10, 25, 32).
Performance Curves
Selection of Cartridges
Sleeve 1,Poppet 1 Sleeve 1, Poppet 2 Sleeve 1, Poppet 4 Sleeve 3, Poppet 4 Sleeve 3, Poppet A Sleeve 3, Poppet B/C
A Seat
Valve
Nominal
Size
Subplate
Mounting
ISO 6264,
Pilot
Connection
Cap
Version
Sleeve Spool
Type
Y1 Port G1/4"
D4S.indd, dd
Code Description
Omit Standard without Vent Function
09 VV01 with Manual Override De-energized;
10 VV01 without Manual Override power comp. open
11 VV01 with Manual Override De-energized;
12 VV01 without Manual Override power comp. closed
CA Shuttle Valve
DA Shuttle Valve
D4S.indd, dd
D4S.indd, dd
D4S.indd, dd
D4S.indd, dd
D4S.indd, dd
NG ISO-code X1 X2 X3 X4 X5 X6 X7 Y1 Y2 Y3 Y4
42.9 35.8 21.5 7.2 21.5 31.8 66.7 58.8 33.4 7.9
10 6264-06-09-*-97 -
(1.69) (1.41) (0.85) (0.28) (0.85) (1.25) (2.63) (2.31) (1.31) (0.31)
60.3 49.2 39.7 11.1 20.6 44.5 79.4 73.0 39.7 6.4
25 6264-08-13-*-97 -
(2.37) (1.94) (1.56) (0.44) (0.81) (1.75) (3.13) (2.87) (1.56) (0.25)
84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8
32 6264-10-17-*-97
(3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (2.47) (3.81) (3.65) (1.91) (0.15)
NG ISO-code B1 B2 H1 H2 H3 L1 L2 D1 D2 D3 t1 D4 t2 D5 D6
87.3 33.35 83.0 21.0 45.0 29.0 94.8 15.0 7.0 7.1 8.0 16.0 10.8 17.0
10 6264-06-09-*-97 M10
(3.44) (1.31) (3.27) (0.83) (1.77) (1.14) (3.73) (0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
105.0 39.7 109.5 29.0 71.5 34.7 126.8 23.4 7.1 7.1 8.0 18.0 110.8 17.0
25 6264-08-13-*-97 M10
(4.13) (1.56) (4.31) (1.14) (2.81) (1.37) (4.99) (0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
120.0 48.4 120.0 29.0 82.0 30.6 144.3 32.0 7.1 7.1 8.0 20.0 10.8 17.0
32 6264-10-17-*-97 M10
(4.72) (1.91) (4.72) (1.14) (3.23) (1.20) (5.68) (1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Surface Finish
Nitrile Fluorocarbon
10 6264-06-07-*-97 BK 505 4x M10 x 35 DIN 912 12.9 63 Nm S26-58507-0 S26-58507-5
25 6264-08-11-*-97 BK 485 4x M10 x 45 DIN 912 12.9 (46.5 lb.-ft.) S26-58475-0 S26-58475-5
32 6264-10-15-*-97 BK 506 6x M10 x 45 DIN 912 12.9 ±15% S26-58508-0 S26-58508-5
D4S.indd, dd
Note: Shuttle valves only use in connection with vent valve VV01.
D4S.indd, dd
Note: Stroke limiter not for use with D4S03, vent valve VV01, shuttle valve and positon control.
D4S.indd, dd
A
Series D5S seat valves are designed for directional
control functions. They enable individual hydraulic
solutions for nominal flow up to 800 LPM (211.6 GPM)
due to a large variety of poppets, springs and covers,
including shuttle valves, stroke limiters, solenoid valves
(VV01) and position control.
Features
• Leak-free seat valve design.
• 2- and 3-port bodies.
• SAE61 flange.
• Numerous pilot options.
• 6 poppet types. D5S 3-Port D5S 3-Port
D5S.indd, dd
A Seat
Valve
Size Body Pilot Body
Configuration
Pilot
Cap
Sleeve Spool
Type
Code Description
omit Standard without Vent Function
09 VV01 with Manual Override De-energized;
10 VV01 without Manual Override power comp. open
11 VV01 with Manual Override De-energized;
12 VV01 without Manual Override power comp. closed
CA Shuttle Valve
DA Shuttle Valve
D5S.indd, dd
General
A Size
Mounting
06
Flanged according to SAE 61
08 10 12
D5S.indd, dd
D5S 2-Port*
A
D5S 3-Port*
Selection of Cartridges
Sleeve 1, Poppet 1 Sleeve 1, Poppet 2 Sleeve 1, Poppet 4 Sleeve 3, Poppet 4 Sleeve 3, Poppet A Sleeve 3, Poppet B/C
D5S.indd, dd
D5S.indd, dd
D5S 2-Port with Solenoid Valve VV01 and Shuttle Valve Examples
Seat Entry Annular Entry
D5S.indd, dd
D5S 3-Port with Solenoid Valve VV01 and Shuttle Valve Examples
D5S.indd, dd
D5S.indd, dd
D5S.indd, dd
Function
Solenoid de-energized: Pilot oil from X1 to Z
blocks the connection from A to B or B to A.
Solenoid energized: Pilot pressure from X1
is blocked in the VV01. The oil in Z is internally
drained to port B. Allowing flow from A to B,
while B to A remains blocked.
D5S.indd, dd
D5S.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
Size l1 l2 l3 b1 h1 h2 h3 h4 d1 d2
77.0 101.0 22.2 60.0 37.0 47.6 90.0 127.6 19.0 10.5
06
(3.03) (3.98) (0.87) (2.36) (1.46) (1.87) (3.54) (5.02) (0.75) (0.41)
94.0 120.5 26.2 60.0 45.0 52.4 96.0 133.6 25.0 10.5
08
(3.70) (4.74) (1.03) (2.36) (1.77) (2.06) (3.78) (5.26) (0.98) (0.41)
94.0 128.0 30.2 75.0 48.0 58.7 109.0 146.6 32.0 12.5
10
(3.70) (5.04) (1.19) (2.95) (1.89) (2.31) (4.29) (5.77) (1.26) (0.49)
Port size
Ports Function
D5S06 D5S08 D5S10
A Inlet or outlet 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
B Outlet or inlet 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
X1 External pilot port
SAE 4
Y1 External pilot drain
D5S.indd, dd
Seal Kits
A
Size Nitrile Fluorocarbon
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
Size l1 l2 l3 l4 b1 b2 h1 h2 h3 h4 h5 h6 d1 t1 d2 d3
49.0 47.6 56.0 63.0 22.2 60.0 41.0 47.6 28.0 22.2 82.0 119.0 20.0 19.0 10.5
06 3/8" UNC
(1.93) (1.87) (2.20) (2.48) (0.87) (2.36) (1.61) (1.87) (1.10) (0.87) (3.23) (4.69) (0.79) (0.75) (0.41)
55.0 52.4 58.0 65.0 26.2 60.0 47.0 52.4 29.0 26.2 103.0 141.0 23.0 25.0 10.5
08 3/8" UNC
(2.17) (2.06) (2.28) (2.56) (1.03) (2.36) (1.85) (2.06) (1.14) (1.03) (4.06) (5.55) (0.91) (0.98) (0.41)
57.0 58.7 64.0 61.0 30.2 75.0 65.0 58.7 36.0 30.2 113.0 150.0 22.0 32.0 12.5
10 7/16" UNC
(2.24) (2.31) (2.52) (2.40) (1.19) (2.95) (2.56) (2.31) (1.42) (1.19) (4.45) (5.91) (0.87) (1.26) (0.49)
37.0 69.8 55.0 93.0 35.7 80.0 73.0 69.8 72.0 35.7 140.0 178.0 27.0 38.0 13.5
12 1/2" UNC
(1.46) (2.75) (2.17) (3.66) (1.41) (3.15) (2.87) (2.75) (2.83) (1.41) (5.51) (7.01) (1.06) (1.50) (0.53)
Port size
Ports Function
D5S06 D5S08 D5S10 D5S12
A (2x) Inlet or outlet ¾" SAE 61 1" SAE 61 1¼" SAE 61 1½" SAE 61
B Outlet or inlet ¾" SAE 61 1" SAE 61 1¼" SAE 61 1½" SAE 61
X1* External pilot port
Y1 External pilot drain SAE 4
M Pressure gauge
* closed when supplied.
D5S.indd, dd
Parker Sandwich.indd, dd
CM*DD CM*DDF
Parker Sandwich.indd, dd
PRDM*BB
T P A B
Parker Sandwich.indd, dd
PRM*PP, ZDR-P
Parker Sandwich.indd, dd
Features B
• Valve bodies are manufactured from steel which provides
extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.
• Positive shut-off is provided by a fully guided poppet and
allows full flow in the unchecked position.
• Parker CM sandwich style check valves can be used
either on the 'P', 'A', 'B', 'T' ports, or combinations.
• Large internal flow paths allow high flow at low pressure
drop.
Specifications
CM2 CM3 CM6 PSI Bar CM3 Reverse Flow Check
500 34
Mounting NFPA D03, NFPA D05, NFPA D08, 75 PSI
5 PSI
Maximum 76 LPM 113 LPM 340 LPM
Flow (20 GPM) (30 GPM) (90 GPM) 200 14
300 20
Pressure
75 PSI
400 27 75 PSI
200 14
45 PSI
300 20
Pressure
45 PSI
100 7
5 PSI
200 14 5 PSI
0
LPM 0 56.8 113.6 170.3 227.1 283.9 340.6
100 7 15 30 45 60 75 90
GPM
Flow
0 VISCOSITY CORRECTION FACTOR
LPM 0 18.9 37.9 56.8 75.7
GPM 5 10 15 20 Viscosity (SSU) 75 150 200 250 300 350 400
Flow % of P (Approx.) 93 111 119 126 132 137 141
Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure
Parker Sandwich.indd, dd drop will change per chart.
B Code Description
2 NFPA D03
Code Description
PP* P Port Check
Code Type
Omit 5 PSI
Code Type
V Fluorocarbon
Subplate Mounting PT* P and T Port Checks Y 45 PSI* N Nitrile
3 NFPA D05 TT* T Port Check Z 75 PSI*
Subplate Mounting
DD A and B Port Checks * Not available
6 NFPA D08
Subplate Mounting AA A Port Check on 6 size.
BB B Port Check
AAF A Port Inverted
BBF B Port Inverted
DDF A and B Ports Inverted
* Not available on 6 size
1 Sandwich & D1 BK243 73.2 (2.88) 1 Sandwich & D3 BK141 88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) Bolt Kits must be ordered separately. *D31VW with
internal pilot and internal drain only.
Size "6"
Unit Weight:
Sandwich & Valve Bolt Qty/ Torque CM2 0.8 kg (1.7 lbs.)
Combination Kit Description Kit IN-LBS
CM3 1.8 kg (3.9 lbs.)
Sandwich & D6*VW Valve BK121 1/2 - 13 x 5.25
1 6 80 CM6 7.7 kg (17 lbs.)
2 Sandwich & D6*VW Valve BK122 1/2 - 13 x 8.00 6 80
3 Sandwich & D6*VW Valve BK123 1/2 - 13 x 10.75 6 80
4 Sandwich & D6*VW Valve BK124 1/2 - 13 x 13.50 6 80
Note: Bolt Kits must be ordered separately.
Schematics
14.5
7.0 (0.57)
(0.28)
B
T
45.0 A B
(1.77)
Top View
70.0
(2.76)
40.0 38.8
(1.57) (1.53)
3.2
(0.13)
3.2
(0.13)
Face View
A B
Bottom View
Note: Transfer the locating pin to the hole on the opposite side of the valve body for 'T' port option.
(Invert body 180°)
Parker Sandwich.indd, dd
P T
A B B
A
B
T P
TT PP/PT
P T
A B
A B
T P
DD DDF
P T
A B A B
T P
BB BBF
P T
A B A B
P
T
AA AAF
Parker Sandwich.indd, dd
69.9 T T
B
(2.75)
B A
11.9
(0.47)
19.1
(0.75)
Top View
50.0 48.8
(1.97) (1.92)
92.1
(3.63)
Face View
Bottom View
Parker Sandwich.indd, dd
B A
T
B
T
T
T
B A
TT PP/PT
B A
T T
T T
B A
DD DDF
B
A
T T
T T
B A
AA AAF
B A
T T
T T
B A
BB BBF
Parker Sandwich.indd, dd
Top View
Face View
Bottom View
Parker Sandwich.indd, dd
B T P Y
X A B
A B
T P Y X
DD DDF
T P Y
X A B
A B
T P Y
X
AA AAF
T P Y
X A B
A B
T P Y
X
BB BBF
Parker Sandwich.indd, dd
Features
• Parker CPOM sandwich style, p.o. check valves can be
B
provided in either single or double configurations.
• The p.o. checks may be positioned in 'A' port or 'B' port;
or both 'A' and 'B' ports.
• Valve bodies are manufactured from steel providing extra
strength and durability for longer life. Internal hardened
steel components also provide longer life.
• Positive shut-off is provided by a hardened poppet
and cage assembly.
• Large internal flow paths allow high flow at low
pressure drop.
87 6
Maximum 345 Bar 345 Bar 205 Bar
Pressure (5000 PSI) (5000 PSI) (3000 PSI)
free flow
58 4 Maximum 53 LPM 76 LPM 227 LPM
Flow (14 GPM) (20 GPM) (60 GPM)
@ 21 Bar @ 11 Bar @ 24 Bar
piloted open (305 PSI) (155 PSI) (350 PSI)
29 2 Pressure Drop Pressure Drop Pressure Drop
Cracking 1.0 Bar 0.3 Bar 0.4 Bar
Pressure (15 PSI) (5 PSI) (6 PSI)
0
LPM 0 12.5 25 37.5 50 Pilot Ratio
3:1 3:1 3:1
GPM 3.3 6.6 9.9 13.2
Flow Leakage 5 DPM 5 DPM 5 DPM
Pressure Differential
100 6.8
200 13.6
free flow
free flow
piloted open
50 3.4 100 6.8
piloted open
0 0
LPM 0 18.9 37.9 56.8 75.7 LPM 0 37.9 75.7 113.6 151.4 189.3 227.2
GPM 5 10 15 20 GPM 10 20 30 40 50 60
Flow Flow
Viscosity Correction Factor
Curves were generated using 100 SSU hy-
draulic oil. For any other viscosity, pressure Viscosity (SSU) 75 150 200 250 300 350 400
drop will change as per chart.
Percentage of ∆P (Approx.) 93 111 119 126 132 137 141
Parker Sandwich.indd, dd
B Code Description
2 NFPA D03
Code Description
DD Double Poppet
Code Type
Omit** 5 PSI
Code Type
N Nitrile
Subplate Mounting A and B Ports V Fluorocarbon
Y* 45 PSI
3 NFPA D05 AA A Port Only
Subplate Mounting Z* 75 PSI
BB B Port Only
* Available in
6 NFPA D08
Subplate Mounting size 2 only.
** 15 PSI on
CPOM2
Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)
1 Sandwich & D1 BK243 73.2 (2.88) 1 Sandwich & D3 BK141 88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Size "6"
No. of Sandwich & Valve Bolt Bolt Length Unit Weight:
Sandwich Combination Kit mm (in)
CPOM2D 0.8 kg (1.7 lbs.)
1 Sandwich & D6 BK121 133.4 (5.25) CPOM3D 4.4 kg (9.6 lbs.)
2 Sandwich & D6 BK122 203.2 (8.00) CPOM6D 9.5 kg (21.0 lbs.)
3 Sandwich & D6 BK123 273.1 10.75)
4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.
Schematics
Parker Sandwich.indd, dd
33.5
(1.32)
B
T
7.0
(0.28) A
B
P
18.0
(0.71)
40.0
(1.57)
3.2
(0.13)
3.2
(0.13) End View
111.5
(4.39)
129.1
(5.08)
Face View
A B
Bottom View
Parker Sandwich.indd, dd
46.0
(1.81)
B 11.9 P
(0.47)
A B
T T
Top View
69.9
(2.75)
38.2
(1.50)
50.0
(1.97) 28.7
(1.13)
146.1
(5.75) End View
165.1
(6.50)
Face View
Bottom View
Parker Sandwich.indd, dd
B A
x
B
Y
P T
11.1
Top View (0.44) 114.3
11.1
(4.50)
(0.44)
63.5
(2.50)
23.8
(0.94)
69.5
(2.74)
Face View
Bottom View
Parker Sandwich.indd, dd
B Features
• FM style flow control valves can be provided in either
single or double configurations.
• The flow controls may be positioned in 'A' port, 'B' port,
both 'A' and 'B' ports or 'P' port.
• Valve bodies are manufactured from steel providing extra
strength and durability for longer life. Internal hardened
steel components also provide longer life.
• Two step needles provide fine adjustment for the first
few turns and course adjustment for the last few turns.
Standard and fine adjustment needles available.
• Large bypass checks allow high flow at a low pressure
drop.
• Valve is reversible (invert 180°) for meter-in or
meter-out applications (FM2 and FM3 only). Specifications
• Adjustment options include Allen hex or hand knob. FM2 FM3 FM6
Performance Curves Mounting NFPA D03, NFPA D05, NFPA D08,
Pattern CETOP 3, CETOP 5, CETOP 8,
PSI Bar FM2 Reverse Flow Check NG 6 NG 10 NG 25
500 34
Maximum 345 Bar 345 Bar 205 Bar
400 27 Pressure (5000 PSI) (5000 PSI) (3000 PSI)
Maximum 76 LPM 113 LPM 341 LPM
Reverse Flow
Pressure
300 20
Check
Flow (20 GPM) (30 GPM) (90 GPM)
Cracking 0.3 Bar 0.3 Bar 0.3 Bar
200 14 Pressure (5 PSI) (5 PSI) (5 PSI)
P
100 7 2 Pressure Drop P A B T
Reference PP ✽ 2 2 1 ✽ See specific
1
0
7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7
Chart DD 1 ✽ ✽ 1 flow vs. turns
LPM 0
GPM 2 4 6 8 10 12 14 16 18 20 AA 1 ✽ 1 1
Flow BB 1 1 ✽ 1
Turns from Turns from
PSI Bar FM2 Standard Needle Closed PSI Bar FM2**D Fine Needle Closed
1500 102 1500 102 2 4 6 8 10
1 2 4 6
1200 80 1200 80
8
Pressure
Pressure
900 60 900 60
10
600 40 12 600 40
Full Full
Open Open
300 20 300 20
0 0
LPM 0 7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7 LPM 0 7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7
GPM 2 4 6 8 10 12 14 16 18 20 GPM 2 4 6 8 10 12 14 16 18 20
Flow Flow
Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)
1 Sandwich & D1 BK243 73.2 (2.88) 1 Sandwich & D3 BK141 88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Size "6"
No. of Sadnwich & Valve Bolt Bolt Length
Sandwich Combination Kit mm (in)
Unit Weight:
1 Sandwich & D6 BK121 133.4 (5.25)
FM2 1.7 kg (3.8 lbs.)
2 Sandwich & D6 BK122 203.2 (8.00)
FM3 2.4 kg (5.2 lbs.)
3 Sandwich & D6 BK123 273.1 (10.75)
FM6 7.9 kg (17.5 lbs.)
4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.
Schematics
B
BB 1 1 ✽ 1
300 20
Pressure
200 14
Reverse
Flow
Check
100 7
P
1
0
LPM0 18.9 37.9 56.8 75.7 94.6 113.6
GPM 5 10 15 20 25 30
Flow
Turns
PSI Bar FM3 Standard Needle from Closed PSI Bar FM6 Reverse Flow Check
1500 102 500 34
1 2 4 6
1200 80 8 400 27
900 60 300 20
Pressure
Pressure
600 40 10 200 14
12
Full
300 20 Open 100 7
0 0
LPM0 18.9 37.8 56.8 75.7 94.6 113.6 LPM 0 38 76 114 151 189 227 265 303 341
GPM 5 10 15 20 25 30 GPM 10 20 30 40 50 60 70 80 90
Nominal Flow Flow
Turns Turns
PSI Bar FM3**D Fine Needle from Closed PSI Bar FM6 Standard Needle from Closed
1500 102 1500 102 1 2 3 4
1 2 3 4 6 8 5
1200 80 10
1200 80
6
12
900 60
Pressure
14
Full 900 60
Pressure
600 40 Open 8
300 20 10
600 40
12
14
0 16
LPM 0 18.9 37.9 56.8 75.7 94.6 113.6 Full
GPM 5 10 15 20 25 30 300 20 Open
Flow
0
LPM0 38 76 114 151 189 227 265 303 341
GPM 10 20 30 40 50 60 70 80 90
Nominal Flow
Parker Sandwich.indd, dd
Parker Sandwich.indd, dd
Operation
These valves are “normally open” devices that allow
fluid to flow through the controlled port during their
non-actuated or “at rest” condition. When downstream
pressure exceeds the value set by the spring force,
the control piston moves off its seat, closing off the
flow path and thus reducing the fluid passing through
from the main system. The cushioned piston
modulates to maintain the preset pressure in this
branch of the hydraulic circuit. If, due to external
forces, the pressure continues to rise in this branch
circuit, the piston will keep moving against the spring
force allowing fluid to be drained to tank, thereby limit-
ing maximum pressure to the valve’s setting. Specifications
PRDM2 PRDM3
Features Mounting NFPA D03, NFPA D05,
• PRDM sandwich valves may be selected to Pattern CETOP 3, NG6 CETOP 5, NG10
reduce pressure in the 'P' port, 'A' port or 'B' port. Maximum
Operating
• The direct operated, cushioned piston design results in Pressure
fast response, low leakage and minimal hysteresis. P, A, B 350 Bar (5000 PSI) 315 Bar (4560 PSI)
• Up to nine pressure adjustment ranges are available with T 10 Bar (145 PSI) 10 Bar (145 PSI)
maximum pressure settings. Max. Flow 40 LPM (10.5 GPM) 80 LPM (21 GPM)
Maximum
• Adjustment options include: internal hex screw, hand Leakage
knob or internal hex with keylock. P-A 15 ml/min (1.0 cu. in.)
Pressure Code Range
• Fluorocarbon seals are available. Range 01 1.0 to 14 Bar (15 to 200 PSI)
02* 1.5 to 25 Bar (22 to 363 PSI)
• Available gage port connections include SAE, NPT, 05** 2 to 50 Bar (29 to 725 PSI)
Metric and BSPP. 06* 1.5 to 64 Bar (22 to 928 PSI)
10** 4 to 100 Bar (58 to 1450 PSI)
15** 6 to 150 Bar (87 to 2175 PSI)
16* 3 to 160 Bar (44 to 2320 PSI)
21 8 to 210 Bar (116 to 3045 PSI)
35* 10 to 315 Bar (147 to 4560 PSI)
Viscosity
Range 12 to 230 cSt / mm²/s (56 to 1066 SSU)
Filtration ISO Code 18/16/13 or Better
* PRDM2 only
** PRDM3 only.
Parker Sandwich.indd, dd
B
Code Description
2 NFPA D03 Code Type
Code Type
Subplate Mounting N 1/4” NPT
3 NFPA D05 N Nitrile
S SAE #4 (UNF-2B 7/16-20)
Subplate Mounting V Fluorocarbon Adapter in PRDM3
M Metric
Code Type G 1/4" BSPP
Code Description
L Hex w/Key Lock
PP P Port Only
S Internal Hex
AA A Port Only Screw Adj.
BB B Port Only K Knob
Code Description
01 1 to 14 Bar (15 to 200 PSI)
02* 1.5 to 25 Bar (22 to 363 PSI) Bold: Designates Tier I products and options.
05** 2 to 50 Bar (29 to 725 PSI)
06* 1.5 to 64 Bar (22 to 928 PSI) Non-Bold: Designates Tier II products and options.
10** 4 to 100 Bar (58 to 1450 PSI) These products will have longer lead times.
15** 6 to 150 Bar (87 to 2175 PSI)
16* 3 to 160 Bar (44 to 2320 PSI)
21 8 to 210 Bar (116 to 3045 PSI)
35* 10 to 315 Bar (147 to 4560 PSI)
* PRDM2 only.
** PRDM3 only.
Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)
Weights:
PRDM2 1.3 kg (2.9 lbs.)
PRDM3 2.6 kg (5.8 lbs.)
Schematics
T P A B T P A B T P A B
M M M
Parker Sandwich.indd, dd
Parker Sandwich.indd, dd
PRDM3
Inch equivalents for millimeter dimensions are shown in (**)
Parker Sandwich.indd, dd
Operation B
These are "normally open" valves that allow fluid to
pass through the controlled port during typical opera-
tion. When downstream pressure rises above the
value set by an adjustable spring force, the control
pilot opens and allows the main spool to move from
a full open position. The main spool modulates to
maintain the desired "reduced pressure" downstream
of the valve. The PRM3 also has a relieving mode.
Features
• PRM sandwich style pressure reducing valves can be
used to reduce pressure on the 'P' port, the 'A' port, or
the 'B' port.
• Three pressure adjustment options are available: slotted
screw, knob and locking knob. (PRM6 only)
• Valve bodies are manufactured from steel which provide
extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.
Specifications
PRM3 PRM6 PRM3/PRM6
Mounting NFPA D05, NFPA D08, Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638:7)
Pattern CETOP 5, NG 10 CETOP 8, NG 25
Venting Connecting the vent port to tank allows the
Minimum 10 Bar (150 PSI) with rated flow, 150 SSU reducing valve to divert flow at minimum
Pressure oil, and fluid temperature of 38°C (100°F).1 pressure.
Maximum 345 Bar 345 Bar Remote Remote control valve connected to the vent
Pressure (5000 PSI) (5000 PSI) Control port can be used to control the pressure.2
Min. 3.78 LPM 3.78 LPM
Flow (1 GPM) (1 GPM) Drain Drain line from pilot valve is internally
Line connected to the tank port. Tank line
Maximum 64 LPM 189 LPM pressure is thus added to the valve setting.3
Flow (17 GPM) (50 GPM) 1 Change in flow, temperature or fluid (SSU) rating will affect valve
Pressure Code Pressure Range minimum pressure.
Range 07 10 to 70 Bar (150 - 1000 PSI) 2 Set main valve pressure 10 Bar (150 PSI) higher than remote pilot.
17 10 to 175 Bar (150 - 2500 PSI) 3 It is important that the drain line connection be taken into consideration
25 10 to 250 Bar (150 - 3500 PSI) when determining the minimum valve setting.
35 10 to 350 Bar (150 - 5000 PSI)
Parker Sandwich.indd, dd
B
Code Description Omit* SAE
3 NFPA D05 S† SAE
Subplate Mounting N† NPT
6 NFPA D08 M† Metric
Subplate Mounting Code Type
G 1/4 BSPP
N Nitrile * PRM6 only.
Available Models
Code Description PRM3 PRM6 V Fluorocarbon † PRM3 only.
Bolt Kits
Size "3" Size "6"
1 Sandwich & D3 BK141 88.9 (3.50) 1 Sandwich & D6 BK121 133.4 (5.25)
2 Sandwich & D3 BK142 139.7 (5.50) 2 Sandwich & D6 BK122 203.2 (8.00)
3 Sandwich & D3 BK143 190.5 (7.50) 3 Sandwich & D6 BK123 273.1 (10.75)
* D31VW with internal pilot and internal drain only. 4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.
Schematics
VALVE SIDE VALVE SIDE VALVE SIDE
PRM3
PRM6
PA Option AP Option
Parker Sandwich.indd, dd
B
25 250
Pressure Drop
Pressure Drop
300 3000
20 200
15 150
200 2000
10 100
2 Minimum
100 1000 Setting
3
5 5 50
4
0 0
LPM 30 60 RELIEVING REDUCING
0
GPM 3 6 9 12 15 18 LPM 20 10 0 10 20 30
GPM 75 38 0 38 75 113
Flow Rate
Flow Rate
Parker Sandwich.indd, dd
Parker Sandwich.indd, dd
Parker Sandwich.indd, dd
Parker Sandwich.indd, dd
Top View
Bottom View
Parker Sandwich.indd, dd
B Features
• RM sandwich style relief valves can be used to limit pres-
sure in the 'P' port, 'A' port, or 'B' port.
• Valve bodies are manufactured from steel which provide
extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.
• Three pressure adjustment options are available: slotted
screw, knob and locking knob.
• SAE Gage Port
Specifications
RM2 RM3 RM6
Mounting NFPA D03, NFPA D05, NFPA D08, Performance Curves
Pattern CETOP 3, CETOP 5, CETOP 8,
NG 6 NG 10 NG 25
Minimum 10 Bar (150 PSI) with rated flow, 150 SSU
PSI Bar RM2 Override Characteristics
5000 341
Pressure oil, and fluid temperature of 38°C (100°F).1
35 spring
Maximum 350 Bar 350 Bar 350 Bar
4000 273
Pressure (5000 PSI) (5000 PSI) (5000 PSI)
25 spring
Minimum 3.78 LPM 3.78 LPM 3.78 LPM
Flow (1 GPM) (1 GPM) (1 GPM) 3000 205
Pressure
minimum pressure.
2 Not available on Model RM2.
3 Set main valve pressure 10 Bar (150 PSI) higher than remote
pilot.
Parker Sandwich.indd, dd
B
Code Type
2 NFPA D03
N Nitrile
Subplate Mounting
V Fluorocarbon
3 NFPA D05
Subplate Mounting
Code Type
6 NFPA D08
Subplate Mounting K Knob
L Locking Knob
Code Description S Slotted Screw
with Jam Nut
PT Relief P to T
AT* Relief A to T Code Description Unit Weight:
BT* Relief B to T 07 10 to 70 Bar (150 to 1000 PSI) RM2 .95 kg (2.1 lbs.)
17 10 to 175 Bar (150 to 2500 PSI) RM3 3.0 kg (6.6 lbs.)
* RM2 only.
RM6 5.9 kg (13.0 lbs.)
25 10 to 250 Bar (150 to 3500 PSI)
35 10 to 350 Bar (150 to 5000 PSI)
Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)
1 Sandwich & D1 BK243 73.2 (2.88) 1 Sandwich & D3 BK141 88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Size "6"
No. of Sandwich & Valve Bolt Bolt Length
Sandwich Combination Kit mm (in)
Schematics
Parker Sandwich.indd, dd
PSI Bar RM3 Override Characteristics PSI Bar RM6 Override Characteristics
25 spring 25 spring
3000 205 3000 205
B 17 spring 17 spring
Pressure
Pressure
2000 136 2000 136
07 spring 07 spring
1000 68 1000 68
0 0
LPM 0 18.9 37.9 56.8 75.7 LPM 0 95 189 284 379
GPM 5 10 15 20 GPM 25 50 75 100
Flow Flow
PSI Bar RM3 Vent Flow PSI Bar RM6 Vent Press vs. Flow
70 4.8
50 3.4
Pressure
Pressure
30 2.1
20 1.4 50 3.4
10 .7
0 0
LPM0 18.9 37.9 56.8 LPM 0 25 189 284 379
GPM 5 10 15 GPM 25 50 75 100
Flow Flow
Parker Sandwich.indd, dd
169.4
(6.49) 41.4
9.0
(1.63)
@Low Pressure
34.8
(1.37)
B
(0.35)
@Max. Pressure
7.0 T
(0.28) A B
P
3.5
(0.14)
Top View
45.0
(1.77)
SAE 4
40.0
(1.57)
88.0
(3.46)
45.2 (1.78)
P
Needed for 26.2
key removal (1.31)
A B
T
Bottom View
Parker Sandwich.indd, dd
B T
B A
T
72.2 11.9
(2.84) (0.47)
69.9
Top View (2.75)
45.6
(1.80)
15.9
(0.63)
21.4 VENT
27.8
(0.84)
50.0 (1.09)
(1.97)
Face View
45.2 (1.78)
Needed for
key removal 26.2
(1.31)
88.0
(3.46)
Bottom View
GAGE
93.7 SAE 4
19.8 (3.69)
(0.78)
Back View
Parker Sandwich.indd, dd
Top View
End View
Face View
Bottom View
Parker Sandwich.indd, dd
Features
• High flow capacity.
• Sizes::
– ZDR01 – NFPA D03 / NG6 / CETOP 3
– ZDR02 – NFPA D05 / NG10 / CETOP 5
Specifications
General
Size NG6 NG10
Mounting Interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121
Mounting Position Unrestricted
Ambient Temperature Range -20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure up to 350 Bar (5075 PSI); ZDR-AR / BR up to 315 Bar (4568 PSI)
Denison Sandwich.indd, dd
ZDR S0 D
Pressure Port Size Pressure Hexagon Screw Design Seal
Reducing Option Range with Lock Nut Series
Valve
B
Code Description Code Description Code Description
01 NFPA D03 / NG6 1 up to 100 Bar (1450 PSI) 1 Nitrile
02 NFPA D05 / NG10 5* up to 350 Bar (5075 PSI) 5 Fluorocarbon
ZDR01 ZDR02
Performance Curves
ZDR-P/AR/BR01 ZDR-P/AR/BR02
Denison Sandwich.indd, dd
Seal Kit
Seal Order Code
1 098-91184-0
5 098-91185-0
Complete Cartridge
Seal Order Code
1 098-91102-0
5 098-91103-0
Seal Kit
Seal Order Code
1 098-91182-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 098-91102-0
5 098-91103-0
Denison Sandwich.indd, dd
Features
• High flow capacity.
• Pressure function in P, A, B or A + B.
• Sizes:
– ZDV01 – NFPA D03 / NG6 / CETOP 3
– ZDV02 – NFPA D05 / NG10 / CETOP 5
ZDV-B02
Ordering Information
ZDV S0 D
Pressure Port Size Pressure Hexagon Screw Design Seal
Relief Option Range with Lock Nut Series
Valve
Denison Sandwich.indd, dd
ZDV01
ZDV02
Specifications
General
Size NG6 NG10
Mounting DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121
Mounting Position Unrestricted
Ambient Temperature Range -20° to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure up to 350 Bar (5075 PSI); ZDV*ABS up to 315 Bar (4568 PSI)
ZDV-P/A/B/AB02 ZDV-ASB02
Denison Sandwich.indd, dd
Seal Kit
Seal Order Code
1 098-91182-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 098-91116-0
5 098-91117-0
Seal Kit
Seal Order Code
1 098-91076-0
5 098-91077-0
Complete Cartridge
Seal Order Code
1 098-91116-0
5 098-91117-0
Denison Sandwich.indd, dd
Features
• Controlled movement loads.
• Load holding via leak-free poppet valve.
• Secondary relief protection for the actuator.
• Sizes:
ZNS-B01
ZNS*01 – NFPA D03 / NG6 / CETOP 3
ZNS*02 – NFPA D05 / NG10 / CETOP 5
Ordering Information
ZNS S0 D
Counterbalance Port Size Pressure Hexagon Screw Design Seal
Valve Option Range with Lock Nut Series
ZNS01 ZNS02
Denison Sandwich.indd, dd
Pressure Range 175 Bar (2538 PSI), 350 Bar (5075 PSI)
Pilot Ratio 4.5 : 1
Leakage On request
Nominal Flow 60 LPM (15.9 GPM) 120 LPM (31.7 GPM)
Opening Pressure 0.3 LPM (0.1 GPM) 0.3 LPM (0.1 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Denison Sandwich.indd, dd
ZNS02
Denison Sandwich.indd, dd
B
Seal Kit
Seal Order Code
1 098-91153-0
5 098-91154-0
Complete Cartridge
Seal Order Code
1 517-01017-2
5 517-00448-8
Seal Kit
Seal Order Code
1 098-91155-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 517-00449-8
5 517-00450-8
Denison Sandwich.indd, dd
Features
• High flow capacity.
• Various functional arrangements.
• Sizes:
– ZRD01 – NFPA D03 / NG6 / CETOP 3
– ZRD02 – NFPA D05 / NG10 / CETOP 5
ZRD-AA02
Ordering Information
ZRD S0 D
Throttle Valve Meter Size Hexagon Design Seal
with Check Option Screw with Series
Lock Nut
Code Description Code Description
AA Meter-out 1 Nitrile
Code Description
Control in A 5 Fluorocarbon
01 NFPA D03 / NG6
AZ Meter-in
Control in A 02 NFPA D05 / NG10
BA Meter-out
Control in B
BZ Meter-in
Control in B
ABA Meter-out
Control in A and B Weight: 1 Cartridge 2 Cartridges
ABZ Meter-in ZRD*01 1.2 kg (2.6 lbs) 1.3 kg (2.9 lbs)
Control in A and B ZRD*02 2.8 kg (6.2 lbs.) 2.9 kg (6.4 lbs.)
ZRD01
ZRD02
(continued on
next page)
Denison Sandwich.indd, dd
ZRD02
Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121 5
Mounting Position Unrestricted
Ambient Temprature -20°C to +50°C (-4°F to +122°F)
Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 80 LPM (21.2 GPM) 160 LPM (42.3 GPM)
Leakage — —
Cracking Pressure — —
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Denison Sandwich.indd, dd
ZRD01
ZRD02
* Throttle closed
Fluid Viscosity 30 cSt @ 50°C (122°F)
Denison Sandwich.indd, dd
Seal Kit
Seal Order Code
B
1 098-91096-0
5 098-91097-0
Complete Cartridge
Order Code
098-91119-0
O-ring Plate
Order Code
S26-27553-0
ZRD02
Inch equivalents for millimeter dimensions are shown in (**)
Seal Kit
Seal Order Code
1 098-91098-0
5 098-91099-0
Complete Cartridge
Order Code
098-91120-0
O-ring Plate
Order Code
S16-85742-0
Denison Sandwich.indd, dd
Features
• High life time.
• Check function in A, B or A + B.
• Sizes:
– ZRE01 – NFPA D03 / NG6 / CETOP 3
– ZRE02 – NFPA D05 / NG10 / CETOP 5
ZRE-A02
Ordering Information
ZRE
Pilot Operated Port Size Design Seal
Check Valve Option Series
ZRE02
Denison Sandwich.indd, dd
Performance Curves
p/Q
ZRE01 ZRE02
Denison Sandwich.indd, dd
Seal
Seal Kit
Order Code
B
1 098-91088-0
5 098-91089-0
ZRE02
Inch equivalents for millimeter dimensions are shown in (**)
Seal Kit
Seal Order Code
1 098-91090-0
5 098-91091-0
Denison Sandwich.indd, dd
Features
• Leakage-free seat.
• High life time.
• Cracking pressure 0.5 Bar (7.25 PSI).
• Sizes:
– ZRV01 – NFPA D03 / NG6 / CETOP 3
– ZRV02 – NFPA D05 / NG10 / CETOP 5
ZRV-P02
Ordering Information
ZRV
Direct Operated Port Size
Check Valve Option
Weight:
ZRV*01 0.7 kg (1.5 lbs)
ZRV*02 2.0 kg (4.4 lbs.)
ZRV01 ZRV02
Denison Sandwich.indd, dd
Denison Sandwich.indd, dd
Denison Sandwich.indd, dd
Hydraulic Fluids
Parker recommends using top-quality hydraulic
fluids having a viscosity range of 32 to 54 cSt
(150 to 250 SSU) at 38°C (100°F). The absolute
Pressure Ratings viscosity range should be 16 to 220 cSt (80 to 1000
Unless otherwise specified, all Parker Sandwich SSU). Fluids should have highest anti-wear character-
valves have continuous duty pressure rating as shown istics and be treated to avoid rust and oxidation.
in this catalog.
Seals
Special Requirements When used with water-glycol, water/oil emulsions, and
Consult your Parker representative for factory recom- high-grade petroleum base hydraulic fluids, Parker
mendations on such situations as: standard nitrile seals are suitable.
When using phosphate ester fluids or their blends,
• Installations that will operate at pressures higher than specify Parker optional seals made of fluorocarbon.
published catalog ratings.
Synthetic fire-resistant fluids require special seal ma-
• Use of hydraulic fluids which do not meet our recom- terials which your Parker representative can recom-
mended specifications. mend.
Denison Sandwich.indd, dd
51.00
(2.000) M5-0.8 (10-24) UNC-2B thread
min. x 10.40 (.410) min. thread depth
40.50
(1.594) 4-holes
0.28
33.00 S A B
B
(1.300) (0.011)
30.20
5.10 (1.190)
(0.200)
21.50
(0.850)
0.75
(0.030) B
O 7.5 (.295) max.
A P.A.B. & T ports
T 0.56
15.50 (0.022)
L A B
31.00 (0.610)
43.00 (1.220)
(1.70) A
min.
25.90
(1.020) O 3.86/4.27 (.152/.168)
31.75 B x 4.00 (.160) min. depth
(1.250)
0.28
(0.011) S A B
P
12.70
(0.500)
4.80 (0.190) R. max. typ.
4 places
91.2
(3.62)
-B-
54.0
(2.13)
50.8
(2.00)
37.3
(1.47)
27.0
(1.06) 16.7
(0.66)
21.4 6.4 3.2
(0.84) (0.25) (0.13)
Denison Sandwich.indd, dd
152.4
(6.00)
-B-
130.2
(5.13) 112.7
(4.44)
100.8
(3.97) 94.5
(3.72)
½ – 13 UNC – 2B x 22.22 min th'd dp.
77.0 (M12) (0.875)
(3.03) 53.2 6 holes
(2.09)
29.4 0.28
17.5 4.8 (1.16) A B
17.5 (0.011) S
(0.69) (0.19)
(0.69)
Denison Sandwich.indd, dd
Features
C • Aluminum or steel available — Flexibility for applying to
different system pressures.
A
E
A
B
E
H E
F
C C C
T
P
G
B
F
G
B
Port
Size A B C D E F G H
E
2* 25.4 63.5 33.3 31.8 12.7 6.4 57.2 22.4
(1.00) (2.50) (1.31) (1.25) (.50) (.25) (2.25) (.88)
D 3* 25.4 63.5 33.3 31.8 12.7 6.4 57.2 22.4
(1.00) (2.50) (1.31) (1.25) (.50) (.25) (2.25) (.88)
4* 38 88.9 46.0 45.2 19.1 6.4 82.5 35.1
(1.50) (3.50) (1.81) (1.78) (.75) (.25) (3.25) (1.38)
6* 44.5 101.6 52.3 51.6 22.4 9.7 92.2 41.4
(1.75) (4.00) (2.06) (2.03) (.88) (.38) (3.63) (1.63)
Subplate-Manifold.indd, dd
I
B
A H
D G
E
J A
C C
C
K T P
F
B
E
F
Port
Size A B C D E F G H I J K
2* 25.4 63.5 33.3 22.4 6.4 57.2 16.8 32.5 48.5 19.1 47.8
(1.00) (2.50) (1.31) (.88) (.25) (2.25) (.66) (1.28) (1.91) (.75) (1.88)
3* 25.4 63.5 33.3 22.4 6.4 57.2 15.0 32.5 50.0 17.5 49.3
(1.00) (2.50) (1.31) (.88) (.25) (2.25) (.59) (1.28) (1.97) (.69) (1.94)
4* 38.1 88.9 46.0 35.1 6.4 82.6 17.5 45.2 71.4 19.1 71.4
(1.50) (3.50) (1.81) (1.38) (.25) (3.25) (.69) (1.78) (2.81) (.75) (2.81)
6* 38.1 114.3 58.7 47.8 9.7 104.9 23.9 57.9 90.4 23.9 90.4
(1.50) (4.50) (2.31) (1.88) (.38) (4.13) (.94) (2.28) (3.56) (.94) (3.56)
Subplate-Manifold.indd, dd
76.2
(3.00)
38.1 “A” (See Chart)
(1.50) 16.8
54.1 Typ.
7.9 (0.66)
20.3 (2.13)
(0.31)
(0.80)
1.88
(47.8)
76.2 55.9
(3.00) 60.5 (2.20)
C
(2.38)
26.9 54.1
Typ.
(1.06) (2.13)
16.0
(0.63) 54.1
(2.13)
7.9
(0.31)
Mounting Hardware
(See Ordering Information for Mounting Hardware details)
No. Stations 1 2 3 4 5 6 7 8
“A” Length 54.1 108.0 162.1 215.9 270.0 323.9 378.0 431.8
mm (inch) (2.13) (4.25) (6.38) (8.50) (10.63) (12.75) (14.88) (17.00)
Wgt., Alum, 1.4 1.8 2.7 3.6 4.1 5.0 5.4 6.4
kg (lbs.) (3) (4) (6) (8) (9) (11) (12) (14)
Wgt., Iron, 2.3 4.1 5.9 7.7 9.5 11.8 13.6 15.4
kg (lbs.) (5) (9) (13) (17) (21) (26) (30) (34)
See Mounting Bolt Kits for bolt information.
Subplate-Manifold.indd, dd
SP D2 35
Subplate Valve Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
Code Description
Code Description
Omit Aluminum,
D2* NFPA D03, 210 Bar (3000 PSI)
NG6, CETOP3
C
S Ductile Iron,
* Consult factory for D03 345 Bar (5000 PSI)
subplates requiring pilot
ports with D1VP.
Code Description Code Description
2N .25 – 18 NPTF Omit Bottom
3N .38 – 18 NPTF A Side
3S -6 SAE
4N .50 – 14 NPTF
4S -8 SAE
6N .75 – 14 NPTF
6S -12 SAE
Subplate-Manifold.indd, dd
SP D2 35
Manifold Number of Valve Port Size and Material Design
Stations Model Thread Type Series
Required
when ordering.
Code Description
1 No. of Stations
C
2 No. of Stations Code Description
3 No. of Stations Omit Aluminum,
4 No. of Stations 210 Bar (3000 PSI)
5 No. of Stations Code Description S Ductile Iron,
6 No. of Stations D2* NFPA D03, 345 Bar (5000 PSI)
7 No. of Stations NG6, CETOP3
8 No. of Stations * Consult factory for D03
manifolds requiring pilot
ports with D1VP.
Port Size
Code Description P & T A & B Gage
N* NPTF .50 .38 .25
S** SAE -10 -8 -6
* 0.25-18 NPTF gage port plug included.
** -6 SAE gage port plug included.
Note: All bolts are SAE grade 8, 10-24 UNC-2A thread, torque to
5.6 N.m. (50 in.-lbs.)
No. Stations 1 2 3 4 5 6 7 8
Wgt., Alum, 1.4 1.8 2.7 3.6 4.1 5.0 5.4 6.4
kg (lbs.) (3) (4) (6) (8) (9) (11) (12) (14)
Wgt., Iron, 2.3 4.1 5.9 7.7 9.5 11.8 13.6 15.4
kg (lbs.) (5) (9) (13) (17) (21) (26) (30) (34)
Subplate-Manifold.indd, dd
34.8 (1.37)
92.0 (3.62)
101.6 (4.00)
9.4 (.37)
69.9 (2.75)
41.2 (1.62)
15.8 (.62)
See Mounting Bolt Kits for bolt information.
79.4 (3.13)
57.2 (2.25) 31.8 (1.25) 36.5 (1.44)
9.4 (.37) 15.9 (.63)
22.2 (.88)
92.0 (3.62)
101.6 (4.00)
88.9 (3.50)
44.5 (1.74) "A" (See Chart)
7.9 (.31)
57.9 (2.28) 82.5 (3.25) TYP.
22.2 (.88)
14.3 (.56)
54.8
(2.16)
60.3
(2.38) 66.7
C
88.9 (2.63)
(3.50)
81.0 (3.19)
7.9 (.31)
25.4 (1.00)
14.3 (.56) 60.3 (2.38)
9.4 (.37)
7.9 (.31)
88.9 (3.50)
25.4 (1.00)
Mounting Hardware
(See Ordering Information for Mounting Hardware details)
No. Stations 1 2 3 4 5 6
“A” Length, mm (in) 82.6 165.1 247.7 330.2 412.8 495.3
(3.25) (6.50) (9.75) (13.00) (16.25) (19.50)
Weight, Alum. 1.8 3.6 5.0 6.4 7.9 9.6
kg (lbs.) (4) (8) (11) (14) (17) (21)
Weight, Iron 4.1 7.7 11.8 15.4 20.1 23.3
kg (lbs.) (9) (17) (26) (34) (43) (51)
See Mounting Bolt Kits for bolt information.
Subplate-Manifold.indd, dd
J Q
L
E
Pilot Port
X on D05H
Y on D05HE
E (Q dimension)
M
Dimensions A B C D E F * G* H I J K L M N O P Q * R * S*
SPD31V**A* 44.5 95.3 120.7 54.1 22.4 20.6 22.4 60.2 64.3 9.7 111.0 85.9 47.8 47.8 22.4 22.4 22.4 — 100.1
(1.75) (3.75) (4.75) (2.13) (0.88) (0.81) (0.88) (2.37) (2.53) (0.38) (4.37) (3.38) (1.88) (1.88) (0.88) (0.88) (0.88) — (3.94)
SPD31D**A* 44.5 95.3 120.7 54.1 22.4 — — 60.2 64.3 9.7 111.0 85.9 47.8 47.8 22.4 22.4 11.2 25.4 100.1
(1.75) (3.75) (4.75) (2.13) (0.88) — — (2.37) (2.53) (0.38) (4.37) (3.38) (1.88) (1.88) (0.88) (0.88) (0.44) (1.00) (3.94)
See Mounting Bolt Kits for bolt information. * Not available with high flow option.
M P
E
C
Pilot Port
X on D05H
D Y on D05HE Q
F R
Dimension A B C D E F G H I J K L * M * N O P Q * R*
SPD31V*** 44.5 114.3 120.7 9.7 111.3 104.9 60.2 73.9 28.4 56.4 84.1 22.4 98.6 28.7 60.5 90.4 15.0 90.4
(1.75) (4.50) (4.75) (0.38) (4.38) (4.13) (2.37) (2.91) (1.12) (2.22) (3.31) (0.88) (3.88) (1.13) (2.38) (3.56) (0.59) (3.56)
SPD31D*** 44.5 114.3 120.7 9.7 111.3 104.9 60.2 73.9 28.4 56.4 84.1 20.6 100.1 28.7 60.5 90.4 — 88.9
(1.75) (4.50) (4.75) (0.38) (4.38) (4.13) (2.37) (2.91) (1.12) (2.22) (3.31) (0.81) (3.94) (1.13) (2.38) (3.56) — (3.50)
See Mounting Bolt Kits for bolt information. * Not available with high flow option.
Subplate-Manifold.indd, dd
82.6
(3.25)
Pilot Port
X on D05HE
C
Y on D05H
Note: Not available with high flow option.
101.6
50.8 (4.00)
(2.00) "A" (see chart)
11.1 9.5 29.4
(0.44) 57.9 82.6
(0.38) (1.16) (2.28) (3.25)
68.3
80.2
104.8 (2.69)
(3.16)
(4.13)
127.0
(5.00)
Pilot Port
X on D05H
Y on D05HE 39.7 82.6
Note: Not available (1.56) (3.25)
with high flow option.
79.4
(3.13)
50.8
38.1
(2.00)
(1.50)
11.1 34.9
(0.44)
(1.38)
11.1
(0.44)
127.0
14.3
(5.00) 34.9 (0.56)
(1.38)
Mounting Hardware
(See Ordering Information for Mounting Hardware details)
No. of Stations 1 2 3 4 5 6
“A” Length 82.6 165.1 247.7 330.2 412.8 495.3
mm (inch) (3.25) (6.50) (9.75) (13.00) (16.25) (19.50)
Weight Alum. 15.4 26.5 37.5 48.5 59.5 72.8
kg (lbs.) (7.00) (12.00) (17.00) (22.00) (27.00) (33.00)
Weight Iron 41.9 83.8 125.7 165.4 187.4 249.2
kg (lbs.) (19.00) (38.00) (57.00) (75.00) (85.00) (113.00)
See Mounting Bolt Kits for bolt information.
Subplate-Manifold.indd, dd
SP 35
Subplate Valve Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
Code Description
D3 NFPA D05,
CETOP5 Code Description
D31V NFPA D05H Omit Aluminum,
D31D
NFPA D05HE,
NG10, CETPOP5H
S
210 Bar (3000 PSI)
Ductile Iron, C
D31 manifolds come standard 345 Bar (5000 PSI)
with high flow capability. For
flows over 20 GPM use D31V
or D31D subplate. It will have
X and Y ports. Code Description
Omit Bottom
A Side
Code Description
# 3N .38 – 18 NPTF
# 4N .50 – 14 NPTF
# 4S -8 SAE
* 6N .75 – 14 NPTF
* 6S -12 SAE
# Sizes 3* and 4* ports available
on SPD3 (NFPA D05) only.
* Size 6* port available on
SPD31 (NFPA D05H and
D05HE) only.
SP D3 35
Manifold Number of Valve Flow Port Size and Material Design
Stations Model Option Thread Type Series
Required
when ordering.
Code Description
1 No. of Stations
C
2 No. of Stations
3 No. of Stations
4 No. of Stations
5 No. of Stations Code Description
6 No. of Stations Omit Aluminum,
210 Bar (3000 PSI)
S Ductile Iron,
345 Bar (5000 PSI)
Code Description
D3 NFPA D05, NG10,
CETOP5
Subplate-Manifold.indd, dd
SP 35
Manifold Number of Valve Port Size and Material Design
Stations Model Thread Type Series
Required
when ordering.
C
Code Description
Code Description
1 No. of Stations
Omit Aluminum,
2 No. of Stations
210 Bar (3000 PSI)
3 No. of Stations
S Ductile Iron,
4 No. of Stations 345 Bar (5000 PSI)
5 No. of Stations
6 No. of Stations
Subplate-Manifold.indd, dd
A C
H M H
G L G
I
D
N
E
J
O
F P
K
B
A
Size A B C D E F G H I J K L M N O P
SPD68*A* 50.8 155.7 114.3 30.2 64.3 115.1 25.4 25.4 12.7 89.7 142.7 57.2 85.9 40.4 91.2 125.5
SPD66NA* (2.00)
(6.13) (4.50) (1.19) (2.53) (4.53) (1.00) (1.00) (0.50) (3.53) (5.62) (2.25) (3.38) (1.59) (3.59) (4.94)
SPD610*A* 76.2 165.1 127.0 33.3 59.2 121.2 28.7 60.5 12.7 94.5 152.4 63.5 92.2 43.9 105.9 131.8
(3.00)
(6.50) (5.00) (1.31) (2.33) (4.77) (1.13) (2.38) (0.50) (3.72) (6.00) (2.50) (3.63) (1.73) (4.17) (5.19)
See Mounting Bolt Kits for bolt information.
Subplate-Manifold.indd, dd
C M (P port)
I L
H K
J
G A (A port)
D
N P
E
Q
R
C
O S
F
B
T (X port)
U (Y port)
Size A B C D E F G H I J K L M N O P Q R S T U
SPD68** 38.1 155.7 117.6 12.7 89.7 142.7 58.7 87.4 — 30.2 30.2 87.4 87.4 42.2 125.5 30.2 65.8 89.7 113.5 31.8 85.9
SPD66N* (1.50) (6.13) (4.63) (0.50) (3.53) (5.62) (2.31) (3.44) — (1.19) (1.19) (3.44) (3.44) (1.66) (4.94) (1.19) (2.59) (3.53) (4.47) (1.25) (3.38)
SPD610** 50.8 193.8 127.0 9.7 108.7 184.2 9.7 92.2 117.6 36.6 44.5 82.6 90.4 46.7 152.4 41.4 84.1 109.5 146.8 36.6 90.4
(2.00) (7.63) (5.00) (0.38) (4.28) (7.25) (0.38) (3.63) (4.63) (1.44) (1.75) (3.25) (3.56) (1.84) (6.00) (1.63) (3.31) (4.31) (5.78) (1.44) (3.56)
See Mounting Bolt Kits for bolt information.
Subplate-Manifold.indd, dd
101.6
(4.00)
39.7
120.7 (1.56) 133.4 (5.25) TYP
C 17.5
(0.69)
60.3 (4.75)
(2.38)
12.7
(0.50)
33.3
(1.31) 95.3 (3.75) 133.4 (5.25) TYP
"A" see chart
94.5
(3.72)
123.8 103.2
(4.87) (4.06)
158.8
(6.25)
50.8
(2.00) 133.4 (5.25) TYP
22.2
(0.88)
27.0 117.5
(1.06) (4.63)
14.3
(0.56)
152.4 14.3
(6.00)
41.3 (0.56)
(1.63)
Mounting Hardware
(See Ordering Information for Mounting Hardware details)
No. of Stations 1 2 3 4 5
“A” Length 133.35 266.7 400.05 533.4 666.75
mm (inch) (5.25) (10.50) (15.75) (21.00) (26.25)
Weight Alum. 5 11 16 22 28
kg (lbs.) (12) (24) (35) (49) (61)
Weight Iron 20 41 62 82 103
kg (lbs.) (45) (90) (136) (181) (226)
See Mounting Bolt Kits for bolt information.
Subplate-Manifold.indd, dd
SP D6 35
Subplate Valve Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
C
NG25, CETOP8 210 Bar (3000 PSI)
S Ductile Iron,
345 Bar (5000 PSI)
Code Description Code Description
6N .75 - 14 NPTF Omit Bottom
8N 1.00 - 11.5 NPTF A Side
8S -16 SAE
10N 1.25 - 11.5 NPTF
10S -20 SAE
Mounting Hardware
supplied with subplate includes:
Subplates Mounting Hardware Qty.
SPD66NA* .50-13 UNC x 2
SPD68NA* 1.75 LG. SHCS
SPD68SA*
SPD610NA* .50-13 UNC x 2 Note: 35 Design Series subplates conform to NFPA mounting
SPD610SA* 3.00 LG. SHCS pattern specifications, but may be dimensionally different from
previous design series.
SPD66N* .50-13 UNC x 2
SPD68N* 1.50 LG. SHCS
SPD68S*
SPD610N* .38-16 UNC x 4
SPD610S* 2.00 LG. SHCS
Mounting Bolt Kits
Valve mounting threads:
0.50-13 UNC x 1.19 DP. UNC Bolt Kits for use with D6 and D8
Used for SAE and NPTF ports. Directional Control Valves & Sandwich Valves
Number of Sandwich Valves
@ 2.75" (70mm) thickness
0 1 2 3
D6 BK227 BK121 BK122 BK123
2.50" 5.25" 8.00" 10.75"
D6 plus BK161 BK170 BK171 BK172
tapping plate 3.50" 6.25" 9.00" 11.75"
D8 BK228 BK131 BK132 BK133
3.00" 5.75" 8.50" 11.25"
D8 plus BK173 BK174 BK175 BK114
tapping plate 4.00" 6.75" 9.50" 12.125"
Subplate-Manifold.indd, dd
SP D6 35
Manifold Number of Valve Port Size and Material Design
Stations Model Thread Type Series
Required
when ordering.
Code Description
C
1
2
No. of Stations
No. of Stations
3 No. of Stations Code Description
4 No. of Stations Omit Aluminum,
5 No. of Stations 210 Bar (3000 PSI)
S Ductile Iron,
345 Bar (5000 PSI)
Code Description
D6 NFPA D08,
NG25, CETOP8
Port Size
Mounting hardware supplied with Code Description P, A, B T Y X (opt.) Gage
manifold includes:
N* NPTF 1.00 1.25 .38 .25 .25
(2) steel brackets
For SAE and NPTF ports:
S** SAE -16 -20 -8 -4 -6
(8) 1/2-13 UNC x 1.00 HHCS
(8) .50 SAE N Series washers * 0.25-18 NPT gage port plug included.
** -6 SAE gage port plug included.
Valve mounting threads:
0.50-13 UNC x 1.19 DP.
Used for SAE and NPTF ports.
Subplate-Manifold.indd, dd
42.9
(1.69) 11.1
19.1
(0.75) (0.44)
26.3
C
(1.03)
Note:
Mounting hardware supplied with cover plate.
Includes:
50.8 2-012V-7 O-ring, Qty. 4
(2.00)
0.12 x .25 long locating pin, Qty. 1
10-24 UNC x 1.00 long SHCS, Qty. 4 (SPD2C1EN) or
M5-0.8 x 25 mm long SHCS, Qty. 4 (SPD2C1MN)
42.9
(1.69) 11.1
19.1
(0.44)
(0.75)
26.3
(1.03)
Note:
Mounting hardware supplied with crossover plate.
50.8 Includes:
(2.00) 2-012V-7 O-ring, Qty. 4
0.12 x .25 long locating pin, Qty. 1
10-24 UNC x 1.00 long SHCS, Qty. 4 (SPD2D1EN) or
M5-0.8 x 25 mm long SHCS, Qty. 4 (SPD2D1MN)
42.9
(1.69)
11.2
19.1
(0.44)
(0.75)
26.3
(1.03)
50.8
(2.00) Note:
Mounting hardware supplied with cover plate.
Includes:
2-016V-7 O-ring, Qty. 2
0.12 x .25 long locating pin, Qty. 1
10-24 UNC x 1.00 long SHCS, Qty. 4 (SPD2A1EN) or
M5-0.8 x 25 mm long SHCS, Qty. 4 (SPD2A1MN)
Subplate-Manifold.indd, dd
34.9
C
(1.37)
69.9
(2.75) Note:
Mounting hardware supplied with cover plate.
Includes:
2-014V-7 O-ring, Qty. 5
0.25-20 UNC x 1.25 long SHCS, Qty. 4 (SPD3C1EN) or
M6-1.0 x 30 mm long SHCS, Qty. 4 (SPD3C1MN)
38.1
(1.50)
76.2
(3.00) Note:
Mounting hardware supplied with crossover plate.
Includes:
2-014V-7 O-ring, Qty. 5
0.25-20 UNC x 1.25 long SHCS, Qty. 4 (SPD3D1EN) or
M6-1.0 x 30 mm long SHCS, Qty. 4 (SPD3D1MN)
34.9
(1.38)
76.2 Note:
(3.00) Mounting hardware supplied with crossover plate.
Includes:
2-014V-7 O-ring, Qty. 1
2-022V-7 +O-ring, Qty. 2
0.25-20 UNC x 2.00 long SHCS, Qty. 4 (SPD3A1EN) or
M6-1.0 x 50 mm long SHCS, Qty. 4 (SPD3A1MN)
Subplate-Manifold.indd, dd
54.0
(2.12)
101.6
(4.00) Note:
Mounting hardware supplied with crossover plate.
Includes:
2-011V-7 O-ring, Qty. 1
2-014V-7 O-ring, Qty. 6
2-016V-7 O-ring, Qty. 1
0.25-20 UNC x 1.25 long SHCS, Qty. 4 (SPD31VD1EN) or
M6-1.0 x 30 mm long SHCS, Qty. 4 (SPD31VD1MN)
69.9
38.1 (2.75)
51.6
(1.50)
(2.03)
50.8
(2.00)
Note:
101.6 Mounting hardware supplied with crossover plate.
(4.00) Includes:
2-011V-7 O-ring, Qty. 1
2-014V-7 O-ring, Qty. 2
2-016V-7 O-ring, Qty. 1
2-022V-7 O-ring, Qty. 2
0.25-20 UNC x 2.00 long SHCS, Qty. 4 (SPD31VA1EN) or
M6-1.0 x 50 mm long SHCS, Qty. 4 (SPD31VA1MN)
Subplate-Manifold.indd, dd
88.1
(3.47)
C 152.4
(6.00) Note:
Mounting hardware supplied with cover plate.
Includes:
2-210V-7 O-ring, Qty. 2
2-215V-7 O-ring, Qty. 4
0.50-13 UNC x 1.75 long SHCS, Qty. 6 (SPD6C1EN) or
M12-1.75 x 45 mm long SHCS, Qty. 6 (SPD6C1MN)
0.25 x 0.50 long locating pins, Qty. 2
88.1
(3.47)
152.4
(6.00) Note:
Mounting hardware supplied with cover plate.
Includes:
2-210V-7 O-ring, Qty. 2
2-215V-7 O-ring, Qty. 4
0.50-13 UNC x 1.75 long SHCS, Qty. 6 (SPD6C1EN) or
M12-1.75 x 45 mm long SHCS, Qty. 6 (SPD6C1MN)
0.25 x 0.50 long locating pins, Qty. 2
114.3
(4.50)
63.5 85.7
(2.50) (3.38)
88.1
(3.47)
152.4
(6.00) Note:
Mounting hardware supplied with crossover plate.
Includes:
2-210V-7 O-ring, Qty. 2
2-215V-7 O-ring, Qty. 2
2-231V-7 O-ring, Qty. 1
0.50-13 UNC x 3.50 long SHCS, Qty. 6 (SPD6A1EN) or
M12-1.75 x 90 mm long SHCS, Qty. 6 (SPD6A1MN)
0.25 x 0.50 long locating pins, Qty. 2
Subplate-Manifold.indd, dd
Subplate-Manifold.indd, dd
Subplate-Manifold.indd, dd
Subplate-Manifold.indd, dd
Subplate-Manifold.indd, dd
SP D2 35
Subplate Valve Circuit Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
C
Code Description
D2 NFPA D03,
NG6, CETOP3
Code Description
Omit Aluminum,
210 Bar (3000 PSI)
S Ductile Iron,
345 Bar (5000 PSI)
Code Description
A Crossover plate
P to A, B to T
C Parallel Circuit
Cover plate Code Description
D Series Circuit N Cover Plate
Crossover plate
P to T, *P P and T Ports
A and B blocked *W A and B Ports
T Tapping plate
* Tapping plates only
Code Description
*2N 0.25-18 NPTF
ANSI B1.20.3
*2S -4 SAE
ISO 11926; SAE 1926
**1M Metric Mounting Bolts
(M5-0.8 x 25mm long)
**1E English Mounting Bolts
(UNC 10-24 x 1.00 long)
* Tapping plate only
** Cover and crossover plate only
Subplate-Manifold.indd, dd
SP D3 35
Subplate Valve Circuit Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
C
Code Description
D3 NFPA D05,
NG10, CETOP5
Code Description
Omit Aluminum,
210 Bar (3000 PSI)
S Ductile Iron,
345 Bar (5000 PSI)
Code Description
A Crossover plate
P to A, B to T
C Parallel Circuit
Cover plate Code Description
D Series Circuit
N Cover Plate
Crossover plate
P to T, *P P and T Ports
A and B blocked *W A and B Ports
T Tapping plate * Tapping plates only
Code Description
*2N 0.25-18 NPTF
ANSI B1.20.3
*2S -4 SAE
ISO 11926; SAE 1926
**1M Metric Mounting Bolts
(M6-1.0 x 30mm lg. SHCS
Circuits ‘C’ and ‘D’ only)
(M6-1.0 x 50mm lg.
SHCS Circuit ‘A’ Only)
**1E English Mounting Bolts
(UNC .25-20 x 1.25 lg. SHCS
Circuits ‘C’ and ‘D’ only)
(UNC .25-20 x 2.00 lg.
SHCS Circuit ‘A’ Only)
* Tapping plate only
** Cover and crossover plate only
Subplate-Manifold.indd, dd
SP 35
Subplate Valve Circuit Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
C
Code Description
D31V NFPA D05H, D3P
D31D* NFPA D05HE, Code Description
NG10, CETOP5H
Omit Aluminum,
* Only available with tapping 210 Bar (3000 PSI)
plates. Model D31V cover S Ductile Iron,
and crossover plates can 345 Bar (5000 PSI)
be used for D05H and
D05HE mounting patterns
interchangeably.
Code Description
*2N 0.25-18 NPTF
ANSI B1.20.3
*2S -4 SAE
ISO 11926; SAE 1926
**1M Metric Mounting Bolts
(M6-1.0 x 30mm lg. SHCS
Circuits ‘C’ and ‘D’ only)
(M6-1.0 x 50mm lg. SHCS
Circuit ‘A’ Only)
**1E English Mounting Bolts
(UNC .25-20 x 1.25 lg. SHCS
Circuits ‘C’ and ‘D’ only)
(UNC .25-20 x 2.00 lg.
SHCS Circuit ‘A’ Only)
* Tapping plate only
** Cover and crossover plate only
Subplate-Manifold.indd, dd
SP D6 35
Subplate Valve Circuit Port Size and Port Material Design
Model Thread Type Location Series
Required
when ordering.
C
Code Description
D6 NFPA D08,
NG25, CETOP8
Code Description
Omit Aluminum,
210 Bar (3000 PSI)
S Ductile Iron,
345 Bar (5000 PSI)
Code Description
A Crossover plate
P to A, B to T
C Parallel circuit
Cover plate Code Description
D Series circuit N Cover Plate
Crossover plate *P P and T Ports
P to T,
*W A and B Ports
A and B blocked
*X X and Y Ports
T Tapping plate
* Tapping plates only
Code Description
*2N 0.25-18 NPTF
ANSI B1.20.3
*2S -4 SAE
ISO 11926; SAE 1926
**1M Metric Mounting Bolts
(M12-1.75 x 45mm lg. SHCS
Circuit ‘C’ only)
(M12-1.75 x 60mm lg. SHCS
Circuit ‘D’ only)
(M12-1.75 x 90mm lg. SHCS
Circuit ‘A’ only)
**1E English Mounting Bolts
(UNC .50-13 x 1.75 lg. SHCS
Circuit ‘C’ only)
(UNC .50-13 x 2.25 lg. SHCS
Circuit ‘D’ only)
(UNC .50-13 x 3.50 lg. SHCS
Circuit ‘A’ only)
* Tapping plate only
** Cover and crossover plate only
Subplate-Manifold.indd, dd
51.00
(2.000) M5-0.8 (10-24) UNC-2B thread
min. x 10.40 (.410) min. thread depth
40.50
(1.594) 4-holes
.28
33.00
(.011) S A B
(1.300)
30.20
5.10 (1.190)
(.200)
21.50
(.850)
C
0.75
(.030) B
O 7.5 (.295) max.
A P.A.B. & T ports
T .56
15.50
(.022)
L A B
31.00 (.610)
43.00 (1.220)
(1.70) A
min.
25.90
(1.020) O 3.86/4.27 (.152/.168)
31.75 B x 4.00 (.160) min. depth
(1.250)
.28
(.011) S A B
P
12.70
(.500)
4.80 (.190) R. max. typ.
4 places
72.1
(2.84) min.
54.0
(2.13)
50.8
(2.00)
37.3
(1.47)
27.0
(1.06)
16.7
(.66)
3.2
(.13)
21.4 6.4
(.84) (.25)
57.9 32.5
(2.28) (1.28)
46.0 75.0
min. (1.81) (2.95)
Subplate-Manifold.indd, dd
C
11.1 2.4
(.44) (.09)
21.4 6.4
(.84) (.25)
57.9 32.5
(2.28) 43.6 (1.28) 3.96/4.78 (O.156/.188)
46.0 75.0
min. (1.72)
(1.81) max. X & Y ports (2.95)
.56
(.022)
L A B
P
57.9 32.5 X
43.6 (1.28) Y
(2.28) 46.0 6.3 (O.25) max. 75.0
min. (1.72) A B
(1.81) X & Y ports (2.95)
T
.56
(.022)
L A B
B
11.2 (O.44) max.
P.A.B. & T ports
.56
(.022)
L A B
-B-
130.2
(5.13) 112.7
(4.44)
100.8
(3.97) 94.5
(3.72)
½ – 13 UNC – 2Bx22.22
77.0 min th'd dp.
(3.03) 53.2 (M12) (0.875)
6 holes
(2.09)
29.4 0.28
17.5 4.8 (1.16) A B
17.5 (0.011) S
(0.69) (0.19)
(0.69)
Operation 1
Subplate-Manifold.indd, dd
15.5*
(.61)
31.0 31.8** 25.9* 31.0
(1.22) (1.02) 46.0
(1.25) (1.81) (1.22)
15.5 15.5
(.61) (.61)
31.0** 7.0
7.0 15.5 (1.22) 15.5
(.28) (.61) 28.5 12.7* (.61) (.28)
(1.12) (.50)
31.0 31.0
(1.22) 21.5*
(.85) O 5.5 (.22) (1.22)
Typ.
30.2*
(1.19)
▲ Metric thread only 40.5*
(1.59)
Note:
* Tolerance on these dimensions +/- 0.2
** Tolerance on these dimensions +/- 0.1
Subplate-Manifold.indd, dd
580 40 1160 80
X X
435 30 vo 870 60
P
vu
vu
vo
P
P
290 20 580 40
C 145 10 290 20
0 0
Bar 10 20 30 40 50 60 Bar 20 40 60 80 100 120
0 0
PSI 145 290 435 580 725 870 PSI 290 580 870 1160 1450 1740
Lower Trip Point P vu Lower Trip Point P vu
vu
vo
1305 90 2175 150
P
vo
P
vu
P
345 30 725 50
0 0
Bar 30 60 90 120 150 180 Bar 50 100 150 200 250 300
0 0
PSI 345 870 1305 1740 2175 2610 PSI 725 1450 2175 2900 3625 4350
Lower Trip Point P vu Lower Trip Point P vu
Electrical Connections
F1
Mounting Pattern
31.0 P (inlet)
15.5 (1.22) O 6.8 (.27) max
(0.61)
31.0
(1.22)
15.5
C
(0.61)
M5x10.0 deep
(min.)
DIN 43650
Mounting bolts
M7 Pressure M5x60
Lock (2 req'd)
86.0 Adjustment
(3.39)
75.1
(2.96)
P inlet
40.0
(1.57)
20.0
(0.79)
52.0 20.0
(.79)
(2.05)
124.5 40.0
(4.90) (1.57)
159.5
(6.28)
176.7
(6.96)
Subplate-Manifold.indd, dd
U1
Mounting Pattern
Mounting Bolts
M5x10 (10-24x.40")
Mounting bolts deep (min.)
M5x50 (10-24x2 UNC) P (inlet)
7/16-20 UNF-2B (2 req'd)
O 6.8 (.27) max
C 30.0
(1.18)
15.0
(0.59)
DIN 43650
87.0
(3.43) 75.1
(2.96)
40.0
(1.57)
20.0
(0.79)
1.0 20.0
(0.04) (0.79)
12.0 52.0
P inlet (0.47) (2.05) 40.0
147.0 (1.57)
25.0 (5.79)
(0.98)
177.0
(6.97)
Subplate-Manifold.indd, dd
U2
7/16-20 UNF-2B
Mounting bolts
M5x50 (10-24x2 UNC)
DIN 43650 (2 req'd)
M7 Pressure
Adjustment
87.0 75.1
(2.96)
(3.43)
40.0
(1.57)
20.0
(0.79)
Subplate-Manifold.indd, dd
D
Series R4V.......................................Pressure Relief, Pilot Operated, In-line Pipe Mounted................................. D68
General Description, Operation, Features..................................................................................................... D68
Ordering Information, Performance Curves................................................................................................... D69
Specifications................................................................................................................................................ D70
Dimensions.......................................................................................................................................... D71 - D73
Series R1E02...................................Remote Control Pressure Relief .................................................................. D74
General Description, Features....................................................................................................................... D74
Ordering Information, Specifications, Performance Curves.......................................................................... D75
Dimensions.................................................................................................................................................... D76
Features
• Pilot operated with manual adjustment.
• 2 interfaces:
– Subplate, ISO 6264 (DIN 24340 Form D)
with VV01 vent valve (R4V)
– Subplate, ISO 6264 (DIN 24340 Form E)
with CETOP 03 vent valve (R6V)
• 3 pressure ranges.
• 3 adjustment modes:
D
– Hand knob
– Acorn nut with lead seal
– Key lock
• Remote control via port X.
Function
R6V06 System pressure in port P is applied via the X gallery
to the spring loaded cone in the pilot head. The pilot
head controls the pressure in the Z area on top of the
main cartridge which is additionally kept close by the
main spring.
If the pilot pressure exceeds the setting pressure the
pilot cone opens and thus limits the pilot pressure.
When the system pressure exceeds the pilot pressure
plus the spring force, the main cartridge opens to port
T and limits the pressure in port P to the adjusted level.
Additionally to the relief function, a solenoid operated
vent valve connects the Z area to tank. This allows oil
circulation from P to T at minimum pressure drop. The
vent valve can either be a standard CETOP 03 valves
(mounting form E) or a sandwich unit (mounting form
D). For both types the vent position can be either at the
energized or de‑energized solenoid.
Code 1 Code 9
Code Description
Code Description
03 NG10
1 Nitrile
06 NG25
5 Fluorocarbon
10 NG32
Code Description
1 up to 105 Bar (1523 PSI)
3 up to 210 Bar (3045 PSI)
5 up to 350 Bar (5075 PSI)
Code Description
1 Hand Knob 32mm dia.
(Standard)
3 Acorn Nut with
Lead Seal
4 Key Lock
Weight:
R4V03 2.7 kg (6.0 lbs.)
R4V06 4.5 kg (9.9 (lbs.)
R4V10 6.0 kg (13.2 lbs.)
R6V03 4.5 kg (9.9 lbs.)
R6V06 5.8 kg (12.8 lbs.)
R6V10 7.8 kg (17.2 lbs.)
Code Description
Code Description Code Description G0R 12V
1 Hand Knob G0Q 24V
(Standard) GAR 98V
4
3 Acorn Nut with GAG 205V
Subplate
Lead Seal W30 110V / 50 Hz
Mounting 120V / 60 Hz
4 Key Lock
ISO 6264 W31 230V / 50 Hz
6 240V / 60 Hz
Code Description
09 Solenoid not activated
unpress. circulation
11 Solenoid activated
unpress. circulation
Code Description
0 1) Internal
1 2) External from
Subplate
2 3) External from
Valve Body
(Y-port)
1) Only with drain port 3 Weight:
2) R4V only R4V03 4.4 kg (9.7 lbs.)
3) R6V only R4V06 6.2 kg 13.7 (lbs.)
R4V10 7.7 kg (17.0 lbs.)
R6V03 5.9 kg (13.0 lbs.)
R6V06 7.2 kg (15.9 lbs.)
R6V10 9.2 kg (20.3 lbs.)
D
Permitted 20 to 380 cSt / mm²/s (93 to 1761 SSU)
Fluid Temperature
Recommended +30°C to +50°C (+86°F to +122°F)
Maximum -20°C to +70° (-4°F to +158°F)
Filtration ISO 4406 (1999), 18/16/13
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0.0 66.7 58.8 33.4 7.9 14.3 –
(1.69) (1.41) (0.85) – (0.28) (0.85) (0.00) (2.63) (2.31) (1.31) (0.31) (0.56) –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0.0 79.4 73.0 39.7 6.4 15.9 –
(2.37) (1.94) (1.56) – (0.44) (0.81) (0.00) (3.13) (2.87) (1.56) (0.25) (0.63) –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0.0 96.8 92.8 48.4 3.8 21.4 –
(3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (0.00) (3.81) (3.65) (1.91) (0.15) (0.84) –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-07-*-97 87.3 33.4 83.0 21.0 – – 62.5 – 29.0 94.8 – 143.0 181.0 144.8
(3.44) (1.31) (3.27) (0.83) – – (2.46) – (1.14) (3.73) – (5.63) (7.13) (5.76)
25 6264-08-11-*-97 105.0 39.7 109.5 29.0 – – 89.0 – 34.7 126.8 – 143.0 181.0 144.8
(4.13) (1.56) (4.31) (1.14) – – (3.50) – (1.37) (4.99) – (5.63) (7.13) (5.76)
32 6264-10-15-*-97 120.0 48.4 120.0 29.0 –
(4.72) (1.91) (4.72) (1.14) –
–
–
99.5
(3.92)
– 30.6 144.3 – 143.0 181.0 144.8
– (1.20) (5.68) – (5.63) (7.13) (5.76) D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 6264-06-07-*-97 15.0 7.0 7.1 8.0 M10 16.0 10.8 17.0
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
25 6264-08-11-*-97 23.4 7.1 7.1 8.0 M10 18.0 10.8 17.0
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32 6264-10-15-*-97 32.0 7.1 7.1 8.0 M10 20.0 10.8 17.0
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fuorocarbon Surface Finish
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0.0 – 22.1 – 22.1 53.8 – 26.9 – – –
(2.12) (1.87) (0.00) – (0.87) – (0.87) (2.12) – (1.06) – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70.0 – 35.0 – – –
(2.63) (2.19) (0.94) – (0.44) – (1.31) (2.76) – (1.38) – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
(3.50) (3.00) (1.25) – (0.50) – (1.75) (3.25) – (1.63) – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80.0 26.9 114.0 27.0 88.0 – 25.0 25.0 52.5 118.5 141.0 – 180.0 29.5
(3.15) (1.06) (4.49) (1.06) (3.46) – (0.98) (0.98) (2.07) (4.67) (5.55) – (7.09) (1.16)
25 6264-08-13-*-97 100.0 35.0 117.5 45.5 91.5 – 25.0 12.0 37.9 124.5 141.0 – 180.0 36.5
(3.94) (1.38) (4.63) (1.79) (3.60) – (0.98) (0.47) (1.49) (4.90) (5.55) – (7.09) (1.44)
32
6264-10-17-*-97 120.0 41.3 123.0 52.0 97.0
(4.72) (1.63) (4.83) (2.05) (3.82)
–
–
25.0 13.5 45.0 153.0 141.0 –
(0.98) (0.53) (1.77) (6.02) (5.55) –
180.0 36.5
(7.09) (1.83) D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 6264-06-09-*-97 14.7 4.8 7.5 10.0 M12 20.0 13.5 20.0
(0.58) (0.19) (0.30) (0.39) (0.79) (0.53) (0.79)
25 6264-08-13-*-97 23.4 6.3 7.5 10.0 M16 27.0 17.5 25.0
(0.92) (0.25) (0.30) (0.39) (1.06) (0.69) (0.98)
32 6264-10-17-*-97 32.0 6.3 7.5 10.0 M18 28.0 20.0 30.0
(1.26) (0.25) (0.30) (0.39) (1.10) (0.79) (1.18)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface Finish
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0.0 66.7 58.8 33.4 7.9 14.3 –
(1.69) (1.41) (0.85) – (0.28) (0.85) (0.00) (2.63) (2.31) (1.31) (0.31) (0.56) –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0.0 79.4 73.0 39.7 6.4 15.9 –
(2.37) (1.94) (1.56) – (0.44) (0.81) (0.00) (3.13) (2.87) (1.56) (0.25) (0.63) –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0.0 96.8 92.8 48.4 3.8 21.4 –
(3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (0.00) (3.81) (3.65) (1.91) (0.15) (0.84) –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 B3 H1 H2 H3 H4 L1 L2 L3 L4 L5 L6 L7
10 6264-06-07-*-97 87.3 33.4 70.0 130.0 21.0 68.5 109.5 29.0 94.8 – 143.0 181.0 165.6 144.8
(3.44) (1.31) (2.76) (5.12) (0.83) (2.70) (4.31) (1.14) (3.73) – (5.63) (7.13) (6.52) (5.70)
25 6264-08-11-*-97 105.0 39.7 70.0 156.5 29.0 95.0 136.0 34.7 126.8 – 143.0 181.0 165.6 144.8
(4.13) (1.59) (2.76) (6.16) (1.14) (3.74) (5.35) (1.37) (4.99) – (5.63) (7.13) (6.52) (5.70)
32 6264-10-15-*-97 120.0 48.4 70.0 167.0 29.0 105.5 146.5 30.6 144.3 –
(4.72) (1.91) (2.76) (6.57) (1.14) (4.15) (5.77) (1.20) (5.68) –
143.0 181.0 165.6 144.8
(5.63) (7.13) (6.52) (5.70) D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 6264-06-07-*-97 15.0 7.0 7.1 8.0 M10 16.0 10.8 17.0
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
25 6264-08-11-*-97 23.4 7.1 7.1 8.0 M10 18.0 10.8 17.0
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32 6264-10-15-*-97 32.0 7.1 7.1 8.0 M10 20.0 10.8 17.0
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface Finish
Y: external
drain port
1/8" BSPP
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0.0 – 22.1 – 22.1 53.8 – 26.9 – – –
(2.12) (1.87) (0.00) – (0.87) – (0.87) (2.12) – (1.06) – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70.0 – 35.0 – – –
(2.63) (2.19) (0.91) – (0.44) – (1.31) (2.76) – (1.38) – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
(3.50) (3.00) (1.25) – (0.50) – (1.75) (3.25) – (1.63) – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80.0 26.9 206.0 27.0 88.0 136.5 25.0 12.0 52.5 118.5 163.8 – 180.0 36.5
(3.15) (1.06) (8.11) (1.06)
(3.46)
(5.37) (0.98) (0.47) (2.07) (4.67) (6.45) – (7.09) (1.44)
25 6264-08-13-*-97 100.0 35.0 210.0 45.5 91.5 140.0 25.0 12.0 37.9 124.5 163.8 – 180.0 36.5
(3.94) (1.38) (8.27) (1.79)
(3.60)
(5.51) (0.98) (0.47) (1.49) (4.90) (6.45) – (7.09) (1.44)
32 6264-10-17-*-97 120.0 41.3 215.5 52.0 97.0
(4.72) (1.63) (8.48) (2.05)
145.5 25.0 12.0 45.0 153 163.8 – 180.0 36.5
(3.82)
(5.73) (0.98) (0.47) (1.77) (6.02) (6.45) – (7.09) (1.44) D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 6264-06-09-*-97 14.7 4.8 7.5 10.0 M12 20.0 13.5 20.0
(0.58) (0.19) (0.30) (0.39) (0.79) (0.53) (0.79)
25 6264-08-13-*-97 23.4 6.3 7.5 10.0 M16 27.0 17.5 25.0
(0.92) (0.25) (0.30) (0.39) (1.06) (0.69) (0.98)
32 6264-10-17-*-97 32.0 6.3 7.5 10.0 M18 28.0 20.0 30.0
(1.26) (0.25) (0.30) (0.39) (1.10) (0.79) (1.18)
Seal
Surface Finish
NG ISO-code Bolt Kit Nitrile Fluorocarbon
Specifiactions
Size NFPA D03 / NG6
Mounting Interface ISO 6264
Mounting Position Unrestricted
Ambient
Temperature Range -20°C to +70°C (-4°F to +158°F)
Working Pressure Port P: 350 Bar (5075 PSI)
Port T: depressurized
D Pressure Range
25 Bar (363 PSI)
64 Bar (928 PSI)
160 Bar (2320 PSI)
210 Bar (3045 PSI)
350 Bar (5075 PSI)
Nominal Flow 25 LPM (6.6 GPM)
Features
Pressure Fluid Hydraulic oil as per
DIN 51524 ... 525 • Spool type valve.
Fluid Temperature • Manifold mounting.
Recommended +30°C to +50°C (+86°F to +122°F)
Permitted -20°C to +70°C (-4°F to +158°F)
• 5 pressure ranges.
Viscosity
• 2 adjustment modes.
Recommended 30 to 50 cSt/mm2/s
(139 to 232 SSU)
Permitted 20 to 380 cSt / mm2/s
(93 to 1761 SSU)
Filtration ISO 4406 (1999), 18/16/13
Ordering Information
VS A 06 V
Pressure Relief Pressure Adjustment Size Seal Gage Port Lock Design
Valve Range Screw with Fluorcarbon Series
Hexagon Socket NOTE:
Not required
when ordering.
VS.indd, dd
435 30 870 60
Pressure pe
Pressure pe
290 20 580 40
145 10 290 20
pe min
pe Min
0 0
LPM 0 10 20 25 LPM 0 10 20 25
GPM 2.6 5.3 6.6 GPM 2.6 5.3 6.6
Flow (Q) Flow (Q)
VS.indd, dd
Gage Port
G 6.4 (0.25)
2.5
46.0 (0.10)
(1.81) Ø10.0 (0.39)
Gage Port
Option C
50.0
(1.97)
22
0 0
0 0
D
0 0
0
Ø5.5 (0.22)
36.0 165.0
(1.42) (6.5)
80.5
(3.17) 69.0
Gage Port 40.5 (2.72)
Option M Port A plug mounted
(1.59)
P
5.5 (0.22)
19.5 165.0
(0.77) (6.5)
Seal
Surface Finish Bolt kit DIN912 12.9
Fluorocarbon
VS.indd, dd
D
Features
• Pilot operated unloading valve.
• 3 pressure ranges.
• 2 switching types (series R4U with vent function).
• 3 adjustment modes:
– Hand knob
– Screw with locknut
– Key lock
Performance Curves
PSI Bar Minimum Pressure Curve
435 30
363 25
2903 20
Pressure p
218 15
145 10
73 5
0
0 20 40 60 80 100
Flow (Q) %
R4U.indd, dd
D
4
with Lead Seal
Key Lock
G0Q
GAR
24 VDC
98 VDC
GAG 205 VDC
Code Description W30 110V 50Hz/
1 Internal 120V 60Hz
2 External from Subplate W31 230V 50Hz/
240V 60Hz
Code Description
Omit Standard
without Vent Option
09 Solenoid not active
unpress. circulation
11 Solenoid activivated
unpress. circulation
Weight:
R4U03: 2.7 kg (6.0 lbs.)
R4U06: 4.5 kg (9.9 lbs.)
R4U10: 6.0 kg (13.2 lbs.)
R4U.indd, dd
D
Pressure Fluid Temperature
Recommended +30°C to +50°C (+86°F to +122°F)
Maximum -20°C to +70°C (-4°F to +158°F)
Filtration ISO 4406 (1999), 18/16/13
R4U.indd, dd
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9 – –
(1.69) (1.41) 0.85) (0.28) (0.85) (1.25) (2.63) (2.31) (1.31) (0.31)
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73.0 39.7 6.4 – –
(2.37) (1.94) (1.56) (0.44) (0.81) (1.75) (3.13) (2.87) (1.56) (0.25)
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8 – –
(3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (2.47) (3.81) (3.65) (1.91) (0.15)
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.4 83.0 21.0 62.5 – – – 29.0 94.8 – 141.0 181.0 –
(3.44)
(1.31)
(3.27) (0.83) (2.46) (1.14) (3.73) (5.55) (7.13)
25 5781-08-10-0-00 105.0 39.7 109.5 29.0 89.0 – – – 34.7 126.8 – 141.0 181.0 –
(4.13) (1.56)
(4.31) (1.14)
(3.50) (1.37) (4.99) (5.55) (7.13)
32
5781-10-13-0-00 120.0 48.4 120.0 29.0 99.5
(4.72) (1.91)
(4.72) (1.14)
– – – 30.6 144.3
(3.92) (1.20)
– 141.0 181.0
(5.68) (5.55) (7.13)
–
D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 5781-06-07-0-00 15.0 7.0 7.1 8.0 M10 16.0 10.8 17.0
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
25 5781-08-10-0-00 23.4 7.1 7.1 8.0 M10 18.0 10.8 17.0
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32 5781-10-13-0-00 32.0 7.1 7.1 8.0 M10 20.0 10.8 17.0
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface Finish
R4U.indd, dd
R4U.indd, dd
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9 – –
(1.69) (1.41) (0.85) (0.28) (0.85) (1.25) (2.63) (2.31) (1.31) (0.31)
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73.0 39.7 6.4 – –
(2.37) (1.94) (1.56) (0.44) (0.81) (1.75) (3.13) (2.87) (1.56) (0.25)
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8 – –
3 (3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (2.47) (3.81) (3.65) (1.91) (0.15)
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 B3 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.4 70.0 130.0 21.0 68.5 109.5 – – 29.0 94.8 – 141.0 181.0 165.6
(3.44) (1.31) (2.76) (5.12) (0.83) (2.70) (4.13) (1.14) (3.73) (5.55) (7.13) (6.52)
25 5781-08-10-0-00 105.0 39.7 70.0 156.5 29.0 95.0 136.0 – – 34.7 126.8 – 141.0 181.0 165.6
(4.13) (1.56) (2.76) (6.16) (1.14) (3.74) (5.35) (1.37) (4.99) (5.55) (7.13) (6.52)
32 5781-10-13-0-00 120.0 48.4 70.0 167.0 29.0 105.5 146.5 –
– 30.6 144.3 – 141.0 181.0 165.6
(4.72) (1.91) (2.76) (6.57) (1.14) (4.15) (5.77) (1.20) (5.68) (5.55) (7.13) (6.52) D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 5781-06-07-0-00 15.0 7.0 7.1 8.0 M10 16.0 10.8 17.0
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
25 5781-08-10-0-00 23.4 7.1 7.1 8.0 M10 18.0 10.8 17.0
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32 5781-10-13-0-00 32.0 7.1 7.1 8.0 M10 20.0 10.8 17.0
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface Finish
R4U.indd, dd
Specifications
Size NG10, NG25, NG32
Interface Subplate mounting acc. ISO 5781
Mounting Pos. As desired, horizontal mounting preferred
R 4 R 5 7 B
Pressure Interface Reducing Size Maximum Body Pressure Adjustment Pilot Oil Design Seal Options
Reducing Function Pressure Mounting Range Series Check
Valve 350 Bar (5075 PSI) with
Factory
Code Description
Code Description Code Description
03 NG10
1 up to 105 Bar (1523 PSI) 1 Nitrile
06 NG25
3 up to 210 Bar (3045 PSI) 5 Fluorocarbon
10 NG32
5 up to 350 Bar (5075 PSI)
Mounting: Subplate Code Description
mounting Pilot Drain
Code Description
1 Hand Knob 1 Internal External from Y
Code Interface
32mm dia. Std. 2 Internal External from Y1
Subplate
4 Mounting 3 Acorn Nut
Weight:
ISO 5781 with Lead Seal
R4R03: 4.8 kg (10.6 lbs.)
4 Key Lock
R4R06: 7.2 kg (15.9 lbs.)
R4R10: 13.5 kg (29.8 lbs.)
R4R.indd, dd
5075 350
363 25
Reduced Pressure pA
4350 300
290 20
3625 250
Pressure p
2900 200 218 15
2175 150
145 10
1450 100
73 5
725 50
0 0
LPM 50 100 150 LPM 50 100 150
0 0
GPM 13.2 26.5 39.7 GPM 13.2 26.5 39.7
D
Flow (Q) Flow (Q)
R4R06 1)
PSI Bar Reduced Pressure pA versus Flow Q
5800 400
5075 350
Reduced Pressure pA
4350 300
3625 250
2900 200
2175 150
1450 100
725 50
0
LPM 50 100 150 200 250 300 350
0
GPM 13.2 26.5 39.7 52.9 66.1 79.4 92.6
Flow (Q)
R4R10 1)
1)
Measured at 350 Bar (5075 PSI) primary pressure pB.
R4R.indd, dd
R4R.indd, dd
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 – 31.8 66.7 – 33.4 7.9 – –
(1.69) (1.41) (0.85) – (0.28) – (1.25) (2.63) – (1.31) (0.31) – –
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 – 44.5 79.4 – 39.7 6.4 – –
(2.37) (1.94) (1.56) – (0.44) – (1.75) (3.13) – (1.56) (0.25) – –
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 – 62.7 96.8 – 48.4 3.8 – –
(3.31) (2.66) (2.34) (1.66) (0.66) – (2.47) (3.81) – (1.92) (0.15) – –
Tolerance for all dimensions ±0.2
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L7
10 5781-06-07-0-00 87.3 33.4 83.0 21.0 62.5 – – – 29.0 94.8 60.8 141.0 181.0 38.6
(3.44) (1.31) (3.27) (0.83) (2.46) – – – (1.14) (3.73) (2.39) (5.55) (7.13) (1.52)
25 5781-08-10-0-00 105.0 39.7 109.5 29.0 89.0 – – – 34.7 126.8 60.8 141.0 181.0 38.6
(4.13) (1.56) (4.31) (1.14) (3.50) – – – (1.37) (4.99) (2.39) (5.55) (7.13) (1.52)
32 5781-10-13-0-00 120.0 48.4 120.0 29.0 99.5 – – – 30.6 144.3 60.8 141.0 181.0 38.6
(4.72) (1.91) (4.72) (1.14) (3.92) – – – (1.20) (5.68) (2.39) (5.55) (7.13) (1.52)
D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 5781-06-07-0-00 15.0 7.0 7.1 8.0 M10 16.0 10.8 17.0
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
25 5781-08-10-0-00 23.4 7.1 7.1 8.0 M10 18.0 10.8 17.0
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32 5781-10-13-0-00 32.0 7.1 7.1 8.0 M10 20.0 10.8 17.0
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface Finish
R4R.indd, dd
D Features
• Spool type valve. A P T
• Manifold mounting acc. to ISO 5871.
• 5 pressure ranges at NG6.
• 3 pressure ranges at NG10.
• 2 adjustment modes.
NG10
B Y A
Ordering Information
V M A V
Pressure Maximum Adjustment Size Seal Gage Port Lock Design
Reducing Pressure Screw Fluorocarbon Series
Valve Setting with NOTE:
Hexagon Not required
Socket when ordering.
Weight:
VM*A06 1.3 kg (2.9 lbs.)
VM*A10 3.7 kg (8.2 lbs.)
VM.indd, dd
VM.indd, dd
435 30 870 60
Pressure pe
Pressure pe
290 20 580 40
145 10 290 20
D
0 0
LPM -15 -10 0 10 20 25 LPM -15 -10 0 10 20 25
GPM -4 -2.6 0 2.6 5.3 6.6 GPM -4 -2.6 0 2.6 5.3 6.6
Flow (Q) Flow (Q)
2900 200
2320 160
Pressure pe
1740 120
1160 80
580 40
0
LPM -15 -10 0 10 20 25
GPM -4 -2.6 0 2.6 5.3 6.6
Flow (Q)
VM*10
2900 200
1015 70
725 50
1740 120
580 40
435 30 1160 80
290 20
580 40
145 10
0 0
LPM 30 20 10 0 10 20 30 40 50 60 LPM 30 20 10 0 10 20 30 40 50 60
GPM 7.9 5.3 2.6 0 2.6 5.3 7.9 10.6 13.2 15.9 GPM 7.9 5.3 2.6 0 2.6 5.3 7.9 10.6 13.2 15.9
Flow (Q) Flow (Q)
VM.indd, dd
Seal
Surface Finish Bolt Kit DIN912 12.9
Fluorocarbon
VM.indd, dd
66.0
(2.6)
33.0 35.0
(1.30) (1.38)
D
262.5 for key removing
(10.33)
189.5
(7.44)
25.4 42.9
(1.00) (1.69)
90.0
(3.54)
66.7
3.3 (2.63)
(1.31)
Seal
Surface Finish Bolt Kit DIN912 12.9
Fluorocarbon
Y 84.0
33.3 (3.31)
66.7 (1.31) min.
(2.63) 92.0
58.7 A B (3.62)
(2.31) max.
14.7 7.5
(0.58) (0.30)
X
4.8 M10
(0.19) 61.0
VM.indd, dd (2.40)
VM.indd, dd
Features
• Pilot-operated sequence valve.
• 3 pressure ranges.
• 3 adjustment modes:
– Hand knob
– Acorn nut with lead seal
D – Key lock
Ordering Information
R 4 S 5 7 1 A
Pressure Interface Relief Size Maximum Body Pressure Adjustment External Design Seal
Valve Function Pressure Mounting Range Drain Series
350 Bar (5075 PSI) from
Subplate
Code Description
Code Description Code Description
03 NG10
1 up to 105 Bar (1523 PSI) 1 Nitrile
06 NG25
3 up to 210 Bar (3045 PSI) 5 Fluorocarbon
10 NG32
5 up to 350 Bar (5075 PSI)
Code Description
Code Interface 1 Hand Knob
32mm dia. Std.
Subplate
4 Mounting 3 Acorn Nut
Weight:
ISO 5781 with Lead Seal
R4S03: 2.7 kg (6.0 lbs.)
4 Key Lock
R4S06: 4.5 kg (9.0 lbs.)
R4S10: 6.0 kg (13.2 lbs.)
R4S.indd, dd
General
Size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 5781
Mounting Position As desired, horizontal mounting preferred
Ambient Temperature -20°C to +80°C (-4°F to +176°F)
Hydraulic
Operating Pressure Ports A, B and X up to 350 Bar (5075 PSI), Port Y: depressurized
Pressure Range up to 105, 210, 350 Bar (1523, 3045, 5075 PSI)
Nominal 150 LPM 350 LPM 650 LPM
Flow (39.7 GPM) (92.6 GPM) (172.0 GPM)
Pressure Fluid Hydraulic oil according to DIN 51524 ... 51525
Viscosity Recommended 30 to 50 cSt / mm²/s (139 to 232 SSU)
Maximum 20 to 380 cSt / mm²/s (93 to 1761 SSU)
Pressure Fluid Temperature
Recommended + 30°C to +50°C (+86°F to +122°F)
Maximum -20°C to +70° (-4°F to +158°F)
Filtration ISO 4406 (1999), 18/16/13
D
Performance Curves
Typical pressure curves at closing point
P1 = setting pressure
P2 = operating pressure
Note:
Time and pressure underlap
depend on the characteristics
of a specific system.
R4S.indd, dd
R4S.indd, dd
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 5781-06-07-0-00 42.9 35.8 21.5 – 7.2 21.5 31.8 66.7 58.8 33.4 7.9 – –
(1.69) (1.41) (0.85) (0.28) (0.85) (1.25) (2.63) (2.31) (1.31) (0.31)
25 5781-08-10-0-00 60.3 49.2 39.7 – 11.1 20.6 44.5 79.4 73.0 39.7 6.4 – –
(2.37) (1.94) (1.56) (0.44) (0.81) (1.75) (3.13) (2.87) (1.56) (0.25)
32 5781-10-13-0-00 84.2 67.5 59.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4 3.8 – –
(3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (2.47) (3.81) (3.65) (1.91) (0.15)
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 5781-06-07-0-00 87.3 33.4 83.0 21.0 62.5 – – – 29.0 94.8 – 141.0 181.0 –
(3.44)
(1.31)
(3.27) (0.83) (2.46) (1.14) (3.73) (5.55) (7.13)
25 5781-08-10-0-00 105.0 39.7 109.5 29.0 89.0 – – – 34.7 126.8 – 141.0 181.0 –
(4.13) (1.56)
(4.31) (1.14)
(3.50) (1.37) (4.99) (5.55) (7.13)
32
5781-10-13-0-00 120.0 48.4 120.0 29.0 99.5
(4.72) (1.91)
(4.72) (1.14)
– – – 30.6 144.3
(3.92) (1.20)
– 141.0 181.0
(5.68) (5.55) (7.13)
–
D
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
10 5781-06-07-0-00 15.0 7.0 7.1 8.0 M10 16.0 10.8 17.0
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
25 5781-08-10-0-00 23.4 7.1 7.1 8.0 M10 18.0 10.8 17.0
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32 5781-10-13-0-00 32.0 7.1 7.1 8.0 M10 20.0 10.8 17.0
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface Finish
R4S.indd, dd
Specifications
Size NG6, NG10
Interface ISO 5791
Mounting Pos. Unrestricted
Ambient Temp. -20°C to +80°C (-4°F to +176°F)
Max. Operating Size 6: Ports P and A
Ordering Information
VB A V
Sequence Maximum Adjustment Size Seal Gauge Lock Design
Valve Pressure Screw with Fluorocarbon Port Series
Setting Hexagon Socket NOTE:
Not required
Code Description when ordering.
0251) 25 Bar (363 PSI) Code Description Code Description Code Description
064 64 Bar (938 PSI) 06 NG6 G1) G 1/4" Omit No Lock
1252) 125 Bar (1813 PSI) 10 NG10 M M12x1.5 Z Cylinder Lock
1601) 160 Bar (2320 PSI) 1)
only NG6
210 210 Bar (3045 PSI)
3501) 350 Bar (5075 PSI)
1)
only NG6
2)
only NG10 Weight:
VB*A06 1.3 kg (2.9 lbs.)
VB*A10 3.7 kg (8.2 lbs.)
VB.indd, dd
435 30 870 60
Pressure pe
Pressure pe
290 20 580 40
145 10 290 20
Pe min Pe min
0 0
LPM 10 20 25 LPM 10 20 25
D
0 0
GPM 2.6 5.3 6.6 GPM 2.6 5.3 6.6
Flow (Q) Flow (Q)
2610 180
Pressure pe
1740 120
870 60
Pe min
0
LPM 10 20 25
0
GPM 2.6 5.3 6.6
Flow (Q)
VB*10
Maximum Setting Pressure Maximum Setting Pressure
PSI Bar 64 Bar (928 PSI) PSI Bar
210 Bar (3045 PSI)
1160 80
2900 200
870 60
2320 160
Pressure pe
Pressure pe
1740 120
580 40
1160 80
290 20
Pe min 580 40
Pe min
0 0
LPM 20 40 60 LPM 20 40 60
0 0
GPM 5.3 10.6 15.9 GPM 5.3 10.6 15.9
Flow (Q) Flow (Q)
VB.indd, dd
Surface Finish
Bolt Kit
BK375 4x M5x30
DIN912 12.9
Seal
Fluorocarbon SK-VB/VM/VS V
T
46.0
25.9±0.2 0.75±0.1 (1.81)
(1.02) A B (2.95)
31.0±0.1 15.5±0.2 32.5±0.1
(1.22) (1.28)
(0.61)
P
Ø4.2x4 deep
(0.17x0.16)
max. 7.2 M5-10 deep
(0.28) (0.20-0.39)
body length 80.0
VB.indd, dd (3.15)
66.0
(2.60)
D
(9.55)
258.5 for lock removing
(10.18)
262.5 for key removing
(10.3)
189.0
Surface Finish (7.44)
25.4 42.9
(1.00) (1.69)
Bolt Kit
BK389 4x M10x50 X
DIN912 12.9
33.3 90.0
(1.31) (3.54)
65 Nm (48 lb.-ft.)
±15% A B 66.7
(2.63)
Seal
Fluorocarbon SK-VB/VM-A10V Y
Subplate Size
SPP3M6B910 A, B = 3/4" BSPP
x, y = 1/4" BSPP
VB.indd, dd
Features NG10
B Y
• Manifold mounting acc. to ISO 5781.
• Type VBY with external drain. NG6 NG10
• Main stage spool type valve.
• Pilot stage seated type valve.
• 4 pressure ranges.
• 2 adjustment modes
D – Screw with hexagon socket A P T
– DIN knob
T
A P T B A X Y B
Specifications
Size NG6 NG10
Mounting Pattern ISO 5781
Mounting Position As desired
Ambient Temperature -20°C to +80°C (-4°F to +176°F)
Operating Pressure, Ports P, A, B up to 315 Bar (4568 PSI) A, B, X up to 315 Bar (4568 PSI)
External Drain Port Pressure T up to 100 Bar (1450 PSI) Y up to 100 Bar (1450 PSI)
Pressure Range 64, 160, 210, 315 Bar (928, 2320, 3045, 4568 PSI)
Pressure Fluid Temperature -20°C to +70°C (-4°F to +158°F)
Viscosity Range
Recommended 30 to 50 cSt / mm²/s (139 to 232 SSU)
Permitted 20 to 380 cSt / mm²/s (93 to 1761 SSU)
Filtration ISO 4406 (1999), 18/16/13
Pilot Oil Flow approx. 500 cm³/min approx. 1000 cm³/min
Ordering Information
VBY
Pressure Relief Pressure Adjustment Size Seal Design
Valve Range Series
NOTE:
Not required
Code Description Code Description Code Description when ordering.
Code Description
064 64 Bar (928 PSI) A Adjustment Screw 06 NG6 N Nitrile
160 160 Bar (2320 PSI) with Hexagon Socket 10 NG10 V Fluorocarbon
210 210 Bar (3045 PSI) H Turning Knob with
Cylinder Lock
315 315 Bar (4568 PSI)
Weight:
VBY*06 2.4 kg (5.29 lbs.)
VBY*10 4.5 kg (9.92 lbs.)
VBY.indd, dd
1015 70
2900 200
870 60
2610 180
725 50
Pressure p
Pressure p
2030 140
580 40
290 20
145 10
870 60 D
pemin 290 20
0 0
LPM 10 20 30 40 LPM 10 20 30 40
0 0
GPM 2.6 5.3 7.9 10.6 GPM 2.6 5.3 7.9 10.6
Flow (Q) Flow (Q)
Pressure p
2610 180
1450 100
VBY.indd, dd
Pressure p
580 40 1740 120
435 30 1305 90
D 290 20
145 10
870
435
60
30
pemin
0 0
LPM 20 40 60 80 100 120 140 160 LPM 20 40 60 80 100 120 140 160
0 0
GPM 5.3 10.6 15.9 21.2 26.1 31.7 32.0 42.3 GPM 5.3 10.6 15.9 21.2 26.1 31.7 32.0 42.3
Flow (Q) Flow (Q)
1740 120
Pressure p
2900 200
Pressure p
1450 100
2175 150
1160 80
VBY.indd, dd
31.0
(1.22)
7.0
(0.28) 40.5
13.5
(0.53) (1.59)
max.
194.0
D
(7.64)
max.
175.0
114.5 (6.89)
(4.51)
144.5
(5.69)
48.0
(1.89)
22.5 0.5
45.0
(0.89) (0.02)
8.0 13.0 65.0 45.0 (1.77)
(0.31) (0.51) (2.56) (1.77)
126.0
(4.96)
VBY.indd, dd
31.8
(1.25)
35.7 Pin at VMY
(1.41)
60.0 83.5 4.5
(2.36) (3.29)
D
149.0 (0.18)
(5.87)
max.
191.0
(7.52) max.
(cylinder 146.0
lock) (5.75)
130.0
max. (5.12)
211.0
(8.31)
for
74.0
key
(2.91) 65.0
removing
(2.56)
VBY.indd, dd
Operation
The system pressure in Port A is applied to the pilot
valve and to the top surface of the main poppet via an
orifice in X. The hydraulically balanced main poppet
is held against the seat by the main spring. In this
state there is no flow through the valve. The adjusted D
spring force acting on the pilot cone determines the
relief pressure. If the pressure in Port A exceeds the
set point, the pilot cone is lifted from its seat, releasing
R5V 3-Port R5V 3-Port
a small pilot flow to tank. The flow through the control
orifice in X creates a pressure drop which limits the Features
pressure at the top of the main poppet to the set point. • Pilot operated with manual adjustment.
The higher system pressure in Port A now lifts the • R5V with 2-port body:
main poppet off its seat and allows flow to Port B. In – 3 sizes (SAE 3/4", 1", 1-1/4")
the resulting float position only enough flow is passed – SAE 61 flange
from Port A to Port B to maintain the inlet pressure in • R5V with 3-port body:
Port A at the set point. When the pressure in Port A – 4 sizes (SAE 3/4", 1", 1-1/4", 1-1/2")
falls below the set point, the hydraulic balance on the – SAE 61 and SAE 62 flange
main poppet is restored. The main spring then forces • 3 pressure stages.
the main poppet to close. • 3 adjustment modes:
– Hand knob
– Acorn nut with lead seal
– Key lock
• With optional vent function.
R5V.indd, dd
D SAE 61
Maximum
Code Size Pressure
3 12 210 Bar Code Description
(3045 PSI) Omit Standard w/o vent function
4 10 280 Bar 09* Solenoid not activ. unpress.
(4060 PSI) circulation
5 06/08 350 Bar 11** Solenoid activated unpress.
(5075 PSI) circulation
SAE 62 * Sol. de-energized: open to tank
Maximum
Sol. energized: vent line blocked.
Code Size Pressure
** Sol. de-energized: vent line blocked
6* 06/08/ 350 Bar
Sol energized: open to tank.
10/12 (5075 PSI)
R5V.indd, dd
D
Pressure Ranges 105 Bar (1523 PSI), 210 Bar (3045 PSI), 350 Bar (5075 PSI)
Nominal Flow 90 LPM 300 LPM 600 LPM 600 LPM
(23.8 GPM) (79.4 GPM) (158.7 GPM) (158.7 GPM)
Fluid Hydraulic oil as per DIN 51524 to 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Electrical (Solenoid)
Duty Ratio 100%
Solenoid Connection Connector as per EN175301-803
Protection Class IP65 in accordance with EN60529 (plugged and mounted)
Code G0R G0Q GAR GAG W30 W31
Supply Voltage 12V 24V 98V 205V 110V at 50Hz/ 220V at 50Hz/
120V at 60Hz 240V at 60Hz
Tolerance Supply Voltage +5 to -10 +5 to -10 +5 to -10 +5 to -10 ±5 ±5
Power Consumption Hold 31W 31W 31W 31W 78W 78W
In Rush 31W 31W 31W 31W 264W 264W
Response Time Energized / De-energized AC 20/18ms, DC 46/27 ms
Maximum Switching Frequency AC up to 7200 switchings/hour; DC up to 16,000 switchings/hour
Coil Insulation Class H (180°C) (356°F)
Performance Curves
R5V.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
SAE 61
Size B1 H1 H2 H3 H4 L1 L2 L3 d1 d2
60.0 131.6 37.0 47.6 90.0 24.6 22.2 152.0 19.0 10.5
06
(2.36) (5.18) (1.46) (1.87) (3.54) (0.97) (0.89) (5.98) (0.75) (0.41)
60.0 137.6 45.0 52.4 96.0 26.5 26.2 171.0 25.0 10.5
08
(2.36) (5.42) (1.77) (2.06) (3.78) (1.04) (1.03) (6.73) (0.98) (0.41)
75.0 150.6 48.0 58.7 109.0 34.0 30.2 179.0 32.0 12.5
10
(2.95) (5.93) (1.89) (2.31) (4.29) (1.34) (1.19) (7.05) (1.26) (0.49)
Port Size
Port Function
R5V06 R5V08 R5V10
A Pressure 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
B Tank 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
Y1 External Drain SAE 4
R5V.indd, dd
SAE 61
Size B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 t1
60.0 22.2 119.0 28.0 22.2 81.0 41.6 47.6 50.3 47.6 63.0 56.0 152.0 19.0 10.5 19.0 20.0
06
(2.36) (0.87) (4.69) (1.10) (0.87) (3.19) (1.64) (1.87) (1.98) (1.87) (2.48) (2.20) (5.98) (0.75) (0.41) (0.75) (0.79)
60.0 26.2 141.0 29.0 26.2 103.0 47.0 52.4 55.8 52.4 65.0 58.0 149.0 25.0 10.5 25.0 23.0
08
(2.36) (1.03) (5.55) (1.14) (1.03) (4.06) (1.85) (2.06) (2.20) (2.06) (2.56) (2.28) (5.87) (0.98) (0.41) (0.98) (0.91)
75.0 30.2 151.0 34.5 30.2 113.0 64.0 58.7 57.8 58.7 61.0 62.0 150.5 32.0 12.5 32.0 22.0
10
(2.95) (1.19) (5.94) (1.36) (1.19) (4.45) (2.52) (2.31) (2.28) (2.31) (2.40) (2.44) (5.93) (1.26) (0.49) (1.26) (0.87)
80.0 35.7 178.0 34.0 35.7 140.0 73.0 69.8 37.3 69.8 92.5 55.2 171.2 38.0 13.5 38.0 27.0
12
(3.15) (1.41) (7.01) (1.34) (1.41) (5.51) (2.87) (2.75) (1.47) (2.75) (3.64) (2.17) (6.74) (1.50) (0.53) (1.50) (1.06)
SAE 62
Size B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 t1
60.0 23.8 119.0 28.0 23.8 81.0 41.6 50.8 50.3 50.8 63.0 56.0 152.0 19.0 10.5 19.0 20.0
06
(2.36) (0.94) (4.69) (1.10) (0.94) (3.19) (1.64) (2.00) (1.98) (2.00) (2.48) (2.20) (5.98) (0.75) (0.41) (0.75) (0.79)
60.0 27.8 141.0 29.0 27.8 103.0 47.0 57.2 55.8 57.2 65.0 58.0 149.0 25.0 12.5 25.0 22.0
08
(2.36) (1.09) (5.55) (1.14) (1.09) (4.06) (1.85) (2.25) (2.20) (2.25) (2.56) (2.28) (5.87) (0.98) (0.49) (0.98) (0.87)
75.0 31.8 151.0 34.5 31.8 113.0 64.0 66.7 57.8 66.7 61.0 62.0 150.5 32.0 13.5 32.0 24.0
10
(2.95) (1.25) (5.94) (1.36) (1.25) (4.45) (2.52) (2.63) (2.28) (2.63) (2.40) (2.44) (5.93) (1.26) (0.53) (1.26) (0.94)
80.0 36.5 178.0 34.0 36.5 140.0 73.0 79.4 37.3 79.4 92.5 55.2 171.2 38.0 17.0 38.0 33.0
12
(3.15) (1.44) (7.01) (1.34) (1.44) (5.51) (2.87) (3.13) (1.47) (3.13) (3.64) (2.17) (6.74) (1.50) (0.67) (1.50) (1.30)
Port size
Port Function
R5V06 R5V08 R5V10 R5V12
A (2) Pressure 3/4" SAE 61/62 1" SAE 61/62 1-1/4" SAE 61/62 1-1/2" SAE 61/62
B Tank 3/4" SAE 61/62 1" SAE 61/62 1-1/4" SAE 61/62 1-1/2" SAE 61/62
X1 External pilot port * SAE 4
Y1 External drain SAE 4
M Pressure gauge SAE 4
R5V.indd, dd * closed when supplied.
11
09
R5V.indd, dd
Features
• Pilot operated with manual adjustment.
• Normally closed to avoid unintended motion.
• 2-port body with SAE61 flange.
• 3 sizes (SAE 3/4", 1", 1-1/4"). D
• 3 pressure stages.
• 3 adjustment modes:
– Hand knob
– Acorn nut with lead seal
– Key lock
• With optional vent function.
• Flow direction B → A.
Ordering Informaton
R5R 2 6 A
Pressure Size SAE 61 2-Port Pressure Adjustment External Switching Solenoid Design Seal Options
Reducing Interface Body Range Drain from Type Voltage Series Check
Valve X1, Y1 = SAE 4 Y1 Port with
Factory
Code Description Code Description Code Description
06 SAE 3/4" 1 Hand Knob Omit Standard w/o
08 SAE 1" 3 Acorn Nut vent function
10 SAE 1-1/4" with Lead Seal G0R 12V
4 Key Lock G0Q 24V
GAR 98V Code Description
GAG 205V 1 Nitrile
W30 110V 50Hz/ 5 Fluorocarbon
Code Size Max. Pressure 120V 60Hz
4 10 280 Bar (4060 PSI) W31 220V 50Hz/
5 06/08 350 Bar (5075 PSI) 240V 60Hz
D Filtration
Electrical (Solenoid)
ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
R5R.indd, dd
D
R5R08*
R5R10*
R5R.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
Size B1 H1 H2 H3 H4 L1 L2 L3 d1 d2
60.0 131.6 37.0 47.6 90.0 24.6 22.2 152.0 19.0 10.5
06
(2.36) (5.18) (1.46) (1.87) (3.54) (0.97) (0.87) (5.98) (0.75) (0.41)
60.0 137.6 45.0 52.4 96.0 26.5 26.2 171.0 25.0 10.5
08
(2.36) (5.42) (1.77) (2.06) (3.78) (1.04) (1.03) (6.73) (0.98) (0.41)
75.0 150.6 48.0 58.7 109.0 34.0 30.2 179.0 32.0 12.5
10
(2.95) (5.93) (1.89) (2.31) (4.29) (1.34) (1.19) (7.05) (1.26) (0.49)
Port Size
Port Function
R5R06 R5R08 R5R10
B Inlet Pressure 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
A Reduced Outlet Pressure 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
Y1 External Drain SAE 4
X1 Pressure Gauge SAE 4
R5R.indd, dd
External Drain
Code 11 Code 09 Vent Valve Seal Kits
Nitrile Fluorocarbon
DC Solenoid
S26-58515-0 S26-58515-5
AC Solenoid
S26-35237-0 S26-35237-5
R5R.indd, dd
Features
• Pilot operated unloading valve.
D • 3-port body with SAE 61 flange.
• 4 sizes (SAE 3/4", 1", 1 1/4", 1 1/2").
• 3 pressure stages.
• 3 adjustment modes: R5U 3-port external drain
– Hand knob
– Acorn nut with lead seal
– Key lock
• With optional vent function.
High Pressure / Low Pressure System
R5U.indd, dd
R5U 3 A
Pressure Size SAE61 3-Port Pressure Adjustment Pilot Oil Switching Solenoid Design Seal Options
Unloading Interface Body Range Type Voltage Series Check
Valve M, Y1, X = SAE 4 with
Factory
Code Description Code Description Code Description
06 SAE 3/4" 1 Hand Knob Omit Standard w/o
08 SAE 1" 3 Acorn Nut vent function
10 SAE 1-1/4" with Lead Seal G0R 12V
12 SAE 1-1/2" 4 Key Lock G0Q 24V
GAR 98V
GAG 205V
W30 110V 50Hz/
120V 60Hz
W31 220V 50Hz/
D
Code Size Max. Pressure Code Pilot Drain
240V 60Hz
3 12 210 Bar (3045 PSI) 4 External via External
4 10 280 Bar (4060 PSI) port X1 or X2
5 06/08 350 Bar (5075 PSI) 5 External via Internal Code Description
port X1 or X2 1 Nitrile
5 Fluorocarbon
Performance Curves
Size 06 08 10 12
Mounting Flanged according to SAE 61
Mounting Position Unrestricted
Ambient Temperature -20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Ports A,B, X 350 Bar (5075 PSI) 350 Bar (5075 PSI) 280 Bar (4060 PSI) 210 Bar (3045 PSI)
Operating
Pressure Ports Y, Y1 30 Bar (435 PSI) 30 Bar (435 PSI) 30 Bar (435 PSI) 30 Bar (435 PSI)
Pressure Ranges 105 Bar (1523 PSI), 210 Bar (3045 PSI), 350 Bar (5075 PSI)
Nominal Flow 90 LPM 300 LPM 600 LPM 600 LPM
(23.8 GPM) (79.4 GPM) (158.7 GPM) (158.7 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
D Fluid Temperature
Viscosity Permitted
-20°C to +80°C (-4°F to +176°F)
10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Electrical
Duty Ratio 100%
Solenoid Connection Connector as per EN175301-803
Protection Class IP65 in accordance with EN60529 (plugged and mounted)
Code G0R G0Q GAR GAG W30 W31
Supply Voltage 12V 24V 98V 205V 110V at 50Hz 220V at 50Hz
120V at 60Hz 240V at 60Hz
Tolerance Supply Voltage +5 to -10 +5 to -10 +5 to -10 +5 to -10 ±5 ±5
Power Consumption Hold 31W 31W 31W 31W 78W 78W
In Rush 31W 31W 31W 31W 264W 264W
Response Time Energized / De-energized AC 20/18ms, DC 46/27 ms
Maximum Switching AC up to 7200 switchings/hour
Frequency DC up to 16,000 switchings/hour
Coil Insulation Class H (180°C) (356°F)
R5U.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
12 S26-27421-0 S26-27421-5
Size B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 d4 t1 d5 L6 H7 H8
60.0 22.2 119.0 28.0 22.2 81.0 41.6 47.6 50.0 47.6 63.0 56.0 152.0 19.0 10.5 19.0 3/8"-16 20.0 3.0
06 – – –
(2.36) (0.87) (4.69) (1.10) (0.87) (3.19) (1.64) (1.87) (1.98) (1.87) (2.48) (2.20) (5.98) (0.75) (0.41) (0.75) UNC (0.79) (0.12)
60.0 26.2 141.0 29.0 26.2 103.0 47.0 52.4 55.8 52.4 65.0 58.0 149.0 25.0 10.5 25.0 3/8"-16 23.0 3.0
08 – – –
(2.36) (1.03) (5.55) (1.14) (1.03) (4.06) (1.85) (2.06) (2.20) (2.06) (2.56) (2.28) (5.87) (0.98) (0.41) (0.98) UNC (0.91) (0.12)
75.0 30.2 151.0 34.5 30.2 113.0 64.0 58.7 57.8 58.7 61.0 62.0 150.5 32.0 12.5 32.0 7/16"-14 22.0 3.0
10 – – –
(2.95) (1.19) (5.94) (1.36) (1.19) (4.45) (2.52) (2.31) (2.28) (2.31) (2.40) (2.44) (5.93) (1.26) (0.49) (1.26) UNC (0.87) (0.12)
80.0 35.7 178.0 34.0 35.7 140.0 73.0 69.8 37.3 69.8 92.5 55.2 171.2 38.0 13.5 38.0 1/2"-13 27.0 3.0 22.4 27.2 73.0
12
(3.15) (1.41) (7.01) (1.34) (1.41) (5.51) (2.87) (2.75) (1.47) (2.75) (3.64) (2.17) (6.74) (1.50) (0.53) (1.50) UNC (1.06) (0.12) (0.88) (1.07) (2.87)
Port Size
Port Function
R5U06 R5U08 R5U10 R5U12
A (2) Pressure 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61 1-1/2" SAE 61
B Tank 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61 1-1/2" SAE 61
X1 External Pilot Port* SAE 4
Y1 External Drain SAE 4
M Pressure Gauge SAE 4
* closed when supplied.
R5U.indd, dd
09
R5U.indd, dd
Features
• Pilot operated with manual adjustment.
• 3-port body with SAE61 flange.
• 3 sizes (SAE 3/4", 1", 1-1/4").
D
• 3 pressure stages:
• 2 adjustment modes:
– Hand knob
– Acorn nut with lead seal
Ordering Information
R5S 3 6 A
Pressure Size SAE 61 3-Port Pressure Adjustment External Design Seal Options
Sequence Interface Body Range Drain from Series Check
Valve Y1, M = SAE 4 Y1 Port with
Factory
Code Description Code Description Code Description
06 SAE 3/4" 1 up to 105 Bar 1 Nitrile
08 SAE 1" (1523 PSI) 5 Fluorocarbon
10 SAE 1-1/4" 3 up to 210 Bar
(3045 PSI)
5 up to 350 Bar
(5075 Bar)
Weight:
Code Size Max. Pressure Code Description
R5S06 3.6 kg (7.9 lbs.)
4 10 280 Bar (4060 PSI) 1 Hand Knob
R5S08 4.6 kg (10.1 lbs.)
5 06/08 350 Bar (5075 PSI) 3 Acorn Nut R5S10 5.2 kg (11.5 lbs.)
with Lead Seal
4 Key Lock
R5S.indd, dd
General
Size 06 08 10
Mounting Flanged according to SAE 61
Mounting Position Unrestricted
Ambient Temperature Range -20°C to +50°C (-4°F to +122°F)
Hydraulic
Max. Operating Pressure Ports A,B 350 Bar 350 Bar 280 Bar
(5075 PSI) (5075 PSI) (4060 PSI)
Ports Y, Y1 30 Bar 30 Bar 30 Bar
(435 PSI) (435 PSI) (435 PSI)
Pressure Ranges 105 Bar (1523 PSI), 210 Bar (3045 PSI), 350 Bar (5075 PSI)
Nominal Flow 90 LPM 300 LPM 600 LPM
D
(23.3 GPM) (79.4 GPM) (158.7 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to 80°C (-4°F to 176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Performance Curve
R5S.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S16-91850-0 S16-91850-5
08 S16-91851-0 S16-91851-5
10 S16-91852-0 S16-91852-5
SAE 61
Size B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 d1 d2 d3 d4 (option 152) t1
60.0 22.2 119.0 28.0 22.2 81.0 41.6 47.6 50.3 47.6 63.0 56.0 152.0 19.0 10.5 19.0 3/8"-16 UNC 20.0
06
(2.36) (0.87) (4.69) (1.10) (0.87) (3.19) (1.64) (1.87) (1.98) (1.87) (2.48) (2.20) (5.98) (0.75) (0.41) (0.75) (M10) (0.79)
60.0 26.2 141.0 29.0 26.2 103.0 47.0 52.4 55.8 52.4 65.0 58.0 149.0 25.0 10.5 25.0 3/8"-16 UNC 23.0
08
(2.36) (1.03) (5.55) (1.14) (1.03) (4.06) (1.85) (2.06) (2.20) (2.06) (2.56) (2.28) (5.87) (0.93) (0.41) (0.98) (M10) (0.91)
75.0 30.2 151.0 34.5 30.2 113.0 64.0 58.7 57.8 58.7 61.0 62.0 150.5 32.0 12.5 32.0 7/16"-14 UNC 22.0
10
(2.95) (1.19) (5.94) (1.36) (1.19) (4.45) (1.52) (2.31) (2.28) (2.31) (2.40) (2.44) (5.93) (1.26) (0.49) (1.26) (M12) (0.87)
Port Size
Port Function
R5S06 R5S08 R5S10
A (2) Pressure 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
B Secondary Port 3/4" SAE 61 1" SAE 61 1-1/4" SAE 61
X1 External Pilot Port* SAE 4
Y1 External Drain SAE 4
M Pressure Gauge SAE 4
* closed when supplied.
R5S.indd, dd
Operation
R4V06 L-Body
The system pressure in Port A is applied to the pilot
valve and to the top surface of the main poppet via an
orifice in X. The hydraulically balanced main poppet
Features
• Pilot operated with manual adjustment.
• 2 interfaces:
– L-body (R4V06-SAE 12, R4V10-SAE 20)
– T-body (R4V03-SAE 8, R4V06-SAE 16)
• 3 pressure stages.
• 3 adjustment modes:
– Hand knob
– Acorn nut with lead seal
– Key lock
R4V.indd, dd
R4V 5 A
Pressure Size Max Body Pressure Adjustment Drain Switching Solenoid Design Seal Options
Relief Valve Pressure Range Line Type Voltage Series Check
350 Bar (Optional) with
(5075 PSI) Factory
Performance Curves*
* The performance curves are measured with external drain. For internal drain, the tank pressure has to be added to the curve.
R4V.indd, dd
D Filtration
Recommended 30 cSt / mm2/s (139 SSU)
ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
R4V.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S26-58507-0 S26-58507-5
08 S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
Size Body B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 H7 H8 L1 L2 L3
85.0 27.5 21.0 59.5 97.5 53.0 92.0
03 T-body – – – – – – – –
(3.35) (1.08) (0.83) (2.34) (3.84) (2.09) (3.62)
136.0 38.0 28.0 93.0 131.0 66.5 117.5
06 T-body – – – – – – – –
(5.35) (1.50) (1.10) (3.66) (5.16) (2.62) (4.63)
Port size
Ports Function
R4V03 T-body R4V06 T-body
A Pressure (inlet) SAE 8 SAE 16
B Tank (outlet) SAE 8 SAE 16
X1) Ext. Remote Control or Vent Connection
SAE 4
Y12) External Drain
1)
closed when supplied
2)
port Y1 is only available at drain line (code 2) external from the pilot head
R4V.indd, dd
Seal Kits
Size Nitrile Fluorocarbon
06 S26-58507-0 S26-58507-5
08 S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
Size Body B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 H7 H8 L1 L2 L3
81.0 76.0 43.0 23.0 51.0 81.0 119.0 49.0
06 L-body – – – – – – –
(3.19) (2.99) (1.69) (0.91) (2.01) (3.19) (4.69) (1.93)
120.7 85.8 77.8 31.8 50.8 96.0 134.0 49.8
10 L-body – – – – – – –
(4.75) (3.38) (3.06) (1.25) (2.00) (3.78) (5.78) (1.96)
Port size
Ports Function
R4V06 L-body R4V10 L-body
A Pressure (inlet) SAE 12 SAE 20
B Tank (outlet) SAE 12 SAE 20
X1) Ext. Remote Control or Vent Connection
SAE 4
Y12) External Drain
1)
closed when supplied
2)
port Y1 is only available at drain line (code 2) external from the pilot head
R4V.indd, dd
11
09
R4V.indd, dd
Features
• Seated type valve.
• 3 body variants:
- foot mounting
D
- front panel mounting
- subplate mounting
• 3 pressure ranges.
• 3 adjustment modes: Subplate Mounting
- hand knobs
- acorn nut with lead seal
- adjusting with lock
R1E02.indd, dd
R1E02 2 A 1
Pressure Interface Pressure Connections Adjustment Design Seal Options
Relief Valve Range G1/4" Series Nitrile Check
with
Factory
Code Description Code Description Code Description
1 Foot Mounting 1 up to 105 Bar (1523 PSI) 1 Hand Knob Ø32mm
2 Front Panel Mounting 3 up to 210 Bar (3045 PSI) 3 Acorn Nut with Lead Seal
3 Subplate Mounting 5 up to 350 Bar (5075 PSI) 4 * Adjusting Device with Lock
(Key Order No. 700-70619)
Weight: Seal Kit: * on bodies for subplate mounting use
R1E021 2.1 kg (4.6 lbs.) R1E021 S26-58466-0 plate S16-64188.
R1E022 2.1 kg (4.6 lbs.) R1E022 S26-58466-0
R1E023 1.0 kg (2.2 lbs.) R1E023 S16-91963-0
Specifications
D
General
Size 1/4"
Interface Foot mounting, Front panel mounting, Subplate mounting
Mounting Position Unrestricted
Ambient Temperature Range -20°C to +70°C (-4°F to +158°F)
Hydraulic
Maximum Operating Pressure Port P 350 Bar (5075 PSI); Port T depressurized
Pressure Range 105 Bar (1523 PSI), 210 Bar (3045 PSI), 350 Bar (5075 PSI)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +70°C (-4°F to +158°F)
Nominal Flow 3.8 LPM (1.0 GPM)
Minimum Pressure Setting 7 Bar (102 PSI)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13
Performance Curve
R1E02.indd, dd
Subplate Mounting
Subplate Size
518-00139-0 3/8" NPT
R1E02.indd, dd
R1E02.indd, dd
2F1C.indd, dd
Operation
The compensator spool is located in front of the meter-
ing spool. The metering spool is closed in the neutral
position to avoid undesired initial actuator motion.
The oil flow to open the metering spool has to pass a
needle valve (not shown in the sectional drawing). The
needle valve can be adjusted from the front panel to
set the response time of the 2F1C.
The metering spool is adjusted by the main control
knob. The key lock has three positions:
Lock: Adjustment is locked.
2F1C 01 B 5
2-Way Flow Size Adjustment Design Seal Reverse Options
Control Valve Knob with Series Flow Check Check
Lock with
Factory
Code Description Fluorocarbon
02 NG10 (3/8")
03 NG16 (3/4")
Code Description
0 Without Check
C With Check
Weight:
2F1C02 6.0 kg (13.2 lbs.)
2F1C03 9.0 kg (19.8 lbs.)
2F1C.indd, dd
2F1C.indd, dd
2F1C02 2F1C03
2F1C02 2F1C03
E 2F1C02 2F1C03
Size ISO-code x1 x2 x3 x4 x5 x6 y1 y2 y3 y4 y5
76.2 79.4 9.5 44.5 19.0 82.5 23.8 30.2 41.3 39.7
02 6263-AM-07-2-A –
(3.00) (3.13) (0.37) (1.75) (0.75) (3.25) (0.94) (1.19) (1.63) (1.56)
101.6 103.2 20.6 52.4 31.8 0.8 101.6 28.6 15.1 75.4 26.2
03 6263-AK-06-2-A
(4.00) (4.06) (0.81) (2.06) (1.25) (0.03) (4.00) (1.13) (0.59) (2.97) (1.03)
Size ISO-code B1 B2 H1 H2 H3 L1 L2 d1 d2 d3 d4
101.6 38.1 119.6 87.4 6.4 95.2 47.6 6.4 57.2 8.7 14.2
02 6263-AM-07-2-A
(4.00) (1.50) (4.71) (3.44) (0.25) (3.75) (1.87) (0.25) (2.25) (0.34) (0.56)
123.8 42.9 121.4 89.2 6.4 123.8 61.9 9.5 57.2 10.5 22.4
03 6263-AK-06-2-A
(4.87) (1.69) (4.78) (3.51) (0.25) (4.87) (2.44) (0.37) (2.25) (0.41) (0.88)
Seal
Size ISO-Code Bolt Kit DIN912 12.9 Surface Finish
Fluorocarbon
02 6263-AM-07-2-A BK-700-70842-8 4xM8x100 31.8 Nm (23.5 lb.-ft.) ±15%
S26-98617-5
03 6263-AK-06-2-A BK395 4xM10x100 63 Nm (46.5 lb.-ft.) ±15%
2F1C.indd, dd
C4V06
Operation
The pressure arising in port A lifts the poppet from the
valve seat and releases the flow to B. In the counter
direction, the spring and the pressure on top of the
cartridge hold the poppet onto the seat and block the
flow.
E Features
• High flow, low pressure drop design.
• Minimal internal leakage.
• Six crack pressure options.
C4V10
Ordering Information
C4V 5 3 0 B
Direct Operated Size Maximum Subplate Approximate Design Seal Options
Check Valve Pressure Mounting Cracking Series Check
350 Bar Pressure with
(5075 PSI) Factory
C4V-DO.indd, dd
Performance Curve
C4V-DO.indd, dd
NG ISO-code x1 x2 x3 x4 x5 y1 y2 B1 B2 H1 H2 H3 L1 L2
42.9 35.8 7.2 31.8 66.7 33.4 87.3 33.4 83.0 21.0 45.0 29.0 94.8
10 5781-06-07-0-00 –
(1.69) (1.41) (0.28) (1.25) (2.63) (1.31) (3.44) (1.31) (3.27) (0.83) (1.77) 1.14) (3.73)
60.3 49.2 11.1 44.5 79.4 39.7 105.0 39.7 109.5 29.0 71.5 34.7 126.8
25 5781-08-10-0-00 –
(2.37) (1.94) (0.44) (1.75) (3.13) (1.56) (4.13) (1.56) (4.31) (1.14) (2.81) (1.37) (4.99)
84.2 67.5 42.1 16.7 62.7 96.8 48.4 120.0 48.4 120.0 29.0 82.0 30.6 144.3
32 5781-10-13-0-00
(3.31) (2.66) (1.66) (0.66) (2.47) (3.81) (1.91) (4.72) (1.91) (4.72) (1.14) (3.23) (1.20) (5.68)
Tolerance for all dimensions ±0.2 mm (0.01 inches)
NG ISO-code d1max d2 t1 d3 t2 d4 d5
15.0 7.1 8.0 16.0 10.8 17.0
10 5781-06-07-0-00 M10
(0.59) (0.28) (0.31) (0.63) (0.43) (0.67)
23.4 7.1 8.0 18.0 10.8 17.0
25 5781-08-10-0-00 M10
(0.92) (0.28) (0.31) (0.71) (0.43) (0.67)
32.0 7.1 8.0 20.0 10.8 17.0
32 5781-10-13-0-00 M10
(1.26) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface finish
68 Nm
10 5781-06-07-0-00 BK505 4xM10 x 35 DIN 912 12.9 (50.2 lb-ft) S16-39362-0 S16-39362-5
±15%
68 Nm
25 5781-08-10-0-00 BK485 4xM10 x 45 DIN 912 12.9 (50.2 lb-ft) S16-39364-0 S16-39364-5
±15%
68 Nm
32 5781-10-13-0-00 BK506 6xM10 x 45 DIN 912 12.9 (50.2 lb-ft) S16-39366-0 S16-39366-5
±15%
C4V-DO.indd, dd
C4V-DO.indd, dd
Operation
When no pressure is applied to the X-port, the flow
from B to A is blocked, because the pressure in B is
also in effect on top of the poppet.
Pressurizing the X port relieves the area on top of the
poppet to the drain port and allows flow from B to A.
E The seat design of the C4V valve series provides leak-
free separation of port A and B in the closed position.
Features
• High flow, low pressure drop design.
• Minimal internal leakage.
Ordering Information
C4V 5 9 B
Pilot Operated Size Maximum Y1 Port Opening Approximate Design Seal Options
Check Valve Pressure G1/4" Ratio Cracking Series Check
350 Bar Pressure with
(5075 PSI) Factory
C4V-PO.indd, dd
Performance Curve
C4V-PO.indd, dd
E
25 5781-08-10-0-00 SPP6M8B910
x, y = 1/4" BSPP
A, B = 1" BSPP
x, y = 1/4" BSPP
32 5781-10-13-0-00 SPP10M12B910 A, B = 1 1/2" BSPP
x, y = 1/4" BSPP
NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
42.9 35.8 7.2 21.5 31.8 66.7 58.8 33.4
10 5781-06-07-0-00 – – – – –
(1.69) (1.41) (0.28) (0.85) (1.25) (2.63) (2.31) (1.31)
60.3 49.2 11.1 20.6 44.5 79.4 73.0 39.7
25 5781-08-10-0-00 – – – – –
(2.37) (1.94) (0.44) (0.81) (1.75) (3.13) (2.87) (1.56)
84.2 67.5 42.1 16.7 24.6 62.7 96.8 92.8 48.4
32 5781-10-13-0-00 – – – –
(3.31) (2.66) (1.66) (0.66) (0.97) (2.47) (3.81) (3.65) (1.91)
Tolerance for all dimensions ±0.2 mm (0.01 inches)
NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
87.3 33.4 83.0 21.0 62.5 29.4 95.2 43.7 111.0 5.0
10 5781-06-07-0-00 – – – –
(3.44) (1.31) (3.27) (0.83) (2.46) (1.16) (3.75) (1.72) (4.37) (0.20)
105 39.7 109.5 29.0 89.0 35.1 127.2 43.7 111.0 5.0
25 5781-08-10-0-00 – – – –
(4.13) (1.56) (4.31) (1.14) (3.50) (1.38) (5.01) (1.72) (4.37) (0.20)
120 48.4 120.0 29.0 99.5 31.0 144.7 43.7 111.0 5.0
32 5781-10-13-0-00 – – – –
(4.72) (1.91) (4.72) (1.14) (3.92) (1.22) (5.70) (1.72) (4.37) (0.20)
NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6
15.0 7.0 7.1 8.0 16.0 10.8 17.0
10 5781-06-07-0-00 M10
(0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67)
23.4 7.1 7.1 8.0 18.0 10.8 17.0
25 5781-08-10-0-00 M10
(0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67)
32.0 7.1 7.1 8.0 20.0 10.8 17.0
32 5781-10-13-0-00 M10
(1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67)
Seal
NG ISO-code Bolt Kit Nitrile Fluorocarbon Surface finish
68 Nm
10 5781-06-07-0-00 BK505 4xM10 x 35 DIN 912 12.9 (50.2 lb-ft) S16-39362-0 S16-39362-5
±15%
68 Nm
25 5781-08-10-0-00 BK485 4xM10 x 45 DIN 912 12.9 (50.2 lb-ft) S16-39364-0 S16-39364-5
±15%
68 Nm
32 5781-10-13-0-00 BK506 6xM10 x 45 DIN 912 12.9 (50.2 lb-ft) S16-39366-0 SS16-39366-5
±15%
C4V-PO.indd, dd
Operation
When no pressure is applied to the X-port, the flow
from B to A is blocked, because the pressure in B is
also in effect on top of the poppet.
Pressurizing the X port relieves the area on top of the
poppet to the drain port and allows flow from B to A.
The seat design of the C5P valve series provides leak-
free separation of port A and B in the closed position.
Features E
• Pilot operated check valve.
• 2-port body with SAE 61 flange.
• 3 sizes (SAE 3/4", 1", 1 1/4").
• 4 opening ratios.
• Valves with position control are available on request.
Ordering Information
C5P 2 A
Pilot Operated Size SAE 61 Pilot Opening Cracking Design Seal Options
Check Valve Interface Ports Ratio Pressure Series Check
with
Factory
Code Description X1 and Y1 = SAE 4 Code Description
06 SAE 3/4" 1 Nitrile
08 SAE 1" 5 Fluorocarbon
10 SAE 1 1/4"
Code Description
1 Pilot Operated
1:1 Ratio Code Size Flow A–B Flow B–A
3 Pilot Operated 2 06 1.0 Bar (14.5 PSI) 1.5 Bar (21.8 PSI)
Code Description 3:1 Ratio 08/10 1.0 Bar (14.5 PSI) 1.7 Bar (24.7 PSI)
4 280 Bar (4060 PSI) 8 Pilot Operated 4 06 4.0 Bar (58.0 PSI) 5.5 Bar (79.8 PSI)
Size 10 (SAE 61) 8:1 Ratio 08/10 3.5 Bar (50.8 PSI) 6.0 Bar (87.0 PSI)
5 350 Bar (5075 PSI) 9 Pilot Operated 6 06 2.0 Bar (29.0 PSI) 3.0 Bar (43.5 PSI)
Sizes 06/08 (SAE 61) 10:1 Ratio 08/10 2.2 Bar (31.9 PSI) 3.8 Bar (55. 1 PSI)
Weight:
C5P06 3.9 kg (8.6 lbs.)
C5P08 4.4 kg (9.7 lbs.)
C5P10 5.7 kg (12.6 lbs.)
C5P.indd, dd
Performance Curves
E C5P06 C5P08
C5P10
C5P.indd, dd
Seal Kits
NG Nitrile Fluorocarbon
06 S26-59404-0 S26-59404-5
08 S26-59405-0 S26-59405-5
10 S26-59406-0 S26-59406-5
Dimensions
Series L1 L2 L3 L4 L5 B1 H1 H2 H3 H4 D1 D2
22.2 95.8 119.8 137.0 67.3 60.0 37.0 47.6 90.0 128.0 19.0 10.5
C5P06
(0.87) (3.77) 4.72) (5.39) (2.65) (2.36) (1.46) (1.87) (3.54) (5.04) (0.75) (0.41)
26.2 112.9 139.4 137.0 67.3 60.0 45.0 52.4 96.0 134.0 25.0 10.5
C5P08
(1.03) (4.44) (5.49) (5.39) (2.65) (2.36) (1.77) (2.06) (3.78) (5.28) (0.93) (0.41)
30.2 112.9 146.9 137.0 67.3 75.0 48.0 58.7 109.0 147.0 32.0 12.5
C5P10
(1.19) (4.44) (5.78) (5.39) (2.65) (2.95) (1.39) (2.31) (4.29) (5.79) (1.26) (0.49)
Ports
Port Size
Port Function
C5P06 C5P08 C5P10
A Inlet or Outlet 3/4" SAE 61 1" SAE 61 1 1/4" SAE 61
B Outlet or Inlet 3/4" SAE 61 1" SAE 61 1 1/4" SAE 61
X1 External Pilot Port SAE 4
Y1 External Pilot Drain SAE 4
C5P.indd, dd
Operation
The ball is held on its seat by a spring under zero pres-
sure condition. When flow is increased to the cracking
pressure, free flow is allowed from port A to port B.
Blocked flow is created when operating pressure and
spring on Port B exceed pressure on port A.
Features
• Direct operated check valve.
• SAE 61 and SAE 62 flanges.
E • 4 sizes (SAE 3/4", 1", 1 1/4", 1 1/2").
• 3 springs.
• 2 different seal configurations.
Ordering Information
C5V B
Direct Operated Size Flange Body Cracking Design Seal Options
Check Valve Sealing Pressure Series
C5V.indd, dd
E
Performance Curves
C5V06 C5V08
C5V10 C5V12
C5V.indd, dd
E C5V06 3/4"
SAE 61
48.0
(1.89)
22.2
(0.87)
27.2
(1.07)
64.0
(2.52)
47.6
(1.87)
22.4
(0.88)
45.0
(1.77)
10.5
(0.41)
Ø3.0
(0.12)
19.0
(0.75)
19.0
(0.75)
48.0 23.8 27.2 64.0 50.8 22.4 45.0 10.5 19.0 19.0
SAE 62 –
(1.89) (0.94) (1.07) (2.52) (2.00) (0.88) (1.77) (0.41) (0.75) (0.75)
60.0 26.2 27.2 74.0 52.4 22.4 45.0 10.5 Ø3.0 25.0 25.0
SAE 61
(2.36) (1.03) (1.07) (2.91) (2.06) (0.88) (1.77) (0.41) (0.12) (0.98) (0.98)
C5V08 1"
60.0 27.8 27.2 74.0 57.2 22.4 45.0 12.5 25.0 25.0
SAE 62 –
(2.36) (1.09) (1.07) (2.91) (2.25) (0.88) (1.77) (0.49) (0.98) (0.98)
68.0 30.2 27.2 85.0 58.7 22.4 50.0 12.5 Ø3.0 32.0 32.0
SAE 61
(2.68) (1.19) (1.07) (3.35) (2.31) (0.88) (1.97) (0.49) (0.12) (1.26) (1.26)
C5V10 1 1/4"
68.0 31.8 27.2 85.0 66.7 22.4 50.0 13.5* 32.0 32.0
SAE 62 –
(2.68) (1.25) (1.07) (3.35) (2.63) (0.88) (1.97) (0.53) (1.26) (1.26)
80.0 35.7 27.2 104.0 69.8 22.4 50.0 13.5 Ø3.0 42.0 38.0
SAE 61
(3.15) (1.41) (1.07) (4.09) (2.75) (0.88) (1.97) (0.53) (0.12) (1.65) (1.50)
C5V12 1 1/2"
80.0 36.5 27.2 104.0 79.4 22.4 50.0 17.0 42.0 38.0
SAE 62 –
(3.15) (1.44) (1.07) (4.09) (3.13) (0.88) (1.97) (0.67) (1.65) (1.50)
* D1 = 15 (0.59) at option code 019 for M14 mounting screws.
Seal Kits
NG Nitrile Fluorocarbon
3 S26-75409-0 S26-75409-5
6 S26-75410-0 S26-75410-5
10 S26-75411-0 S26-75411-5
12 S26-75412-0 S26-75412-5
C5V.indd, dd
E
defects in material or workmanship for a period of eighteen months from the date of Buyer and Seller and constitutes the final, complete and exclusive expression of the
delivery to Buyer. The prices charged for Seller’s products are based upon the exclusive terms of the agreement. All prior or contemporaneous written or oral agreements or
limited warranty stated above, and upon the following disclaimer: DISCLAIMER OF negotiations with respect to the subject matter are herein merged.
WARRANTY: THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY 16. Waiver and Severability. Failure to enforce any provision of this agreement will
PERTAINING TO PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL not waive that provision nor will any such failure prejudice Seller’s right to enforce that
OTHER WARRANTIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY provision in the future. Invalidation of any provision of this agreement by legislation or
AND FITNESS FOR A PARTICULAR PURPOSE. other rule of law shall not invalidate any other provision herein. The remaining provisions
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon of this agreement will remain in full force and effect.
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 17. Termination. This agreement may be terminated by Seller for any reason and at
days of delivery. No other claims against Seller will be allowed unless asserted in writing any time by giving Buyer thirty (30) days written notice of termination. In addition, Seller
within 60 days after delivery or, in the case of an alleged breach of warranty, within 30 may by written notice immediately terminate this agreement for the following: (a) Buyer
days after the date within the warranty period on which the defect is or should have commits a breach of any provision of this agreement (b) the appointment of a trustee,
been discovered by Buyer. Any action based upon breach of this agreement or upon receiver or custodian for all or any part of Buyer’s property (c) the filing of a petition for
any other claim arising out of this sale (other than an action by Seller for any amount relief in bankruptcy of the other Party on its own behalf, or by a third party (d) an assign-
due to Seller from Buyer) must be commenced within thirteen months from the date of ment for the benefit of creditors, or (e) the dissolution or liquidation of the Buyer.
tender of delivery by Seller or, for a cause of action based upon an alleged breach of 18. Governing Law. This agreement and the sale and delivery of all Products here-
warranty, within thirteen months from the date within the warranty period on which the under shall be deemed to have taken place in and shall be governed and construed
defect is or should have been discovered by Buyer. in accordance with the laws of the State of Ohio, as applicable to contracts executed
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, and wholly performed therein and without regard to conflicts of laws principles. Buyer
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE irrevocably agrees and consents to the exclusive jurisdiction and venue of the courts
PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, of Cuyahoga County, Ohio with respect to any dispute, controversy or claim arising
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR out of or relating to this agreement. Disputes between the parties shall not be settled
AS THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE by arbitration unless, after a dispute has arisen, both parties expressly agree in writing
OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY to arbitrate the dispute.
CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER’S 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
WRITTEN CONSENT, EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets
CONTRACT, TORT OR OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S or similar rights except as provided in this Section. Seller will defend and indemnify
LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE Buyer against allegations of infringement of U.S. patents, U.S. trademarks, copyrights,
OF THE PRODUCTS. trade dress and trade secrets (“Intellectual Property Rights”). Seller will defend at its
7. Contingencies. Seller shall not be liable for any default or delay in performance if expense and will pay the cost of any settlement or damages awarded in an action brought
caused by circumstances beyond the reasonable control of Seller. against Buyer based on an allegation that a Product sold pursuant to this Agreement
8. User Responsibility. The user, through its own analysis and testing, is solely infringes the Intellectual Property Rights of a third party. Seller’s obligation to defend
responsible for making the final selection of the system and Product and assuring that and indemnify Buyer is contingent on Buyer notifying Seller within ten (10) days after
all performance, endurance, maintenance, safety and warning requirements of the Buyer becomes aware of such allegations of infringement, and Seller having sole control
application are met. The user must analyze all aspects of the application and follow over the defense of any allegations or actions including all negotiations for settlement or
applicable industry standards and Product information. If Seller provides Product or compromise. If a Product is subject to a claim that it infringes the Intellectual Property
system options, the user is responsible for determining that such data and specifica- Rights of a third party, Seller may, at its sole expense and option, procure for Buyer
tions are suitable and sufficient for all applications and reasonably foreseeable uses the right to continue using the Product, replace or modify the Product so as to make
of the Products or systems. it noninfringing, or offer to accept return of the Product and return the purchase price
9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confi- less a reasonable allowance for depreciation. Notwithstanding the foregoing, Seller shall
dential information or equipment furnished by Buyer or any other items which become have no liability for claims of infringement based on information provided by Buyer, or
Buyer’s property, may be considered obsolete and may be destroyed by Seller after directed to Products delivered hereunder for which the designs are specified in whole
two consecutive years have elapsed without Buyer placing an order for the items which or part by Buyer, or infringements resulting from the modification, combination or use in
are manufactured using such property. Seller shall not be responsible for any loss or a system of any Product sold hereunder. The foregoing provisions of this Section shall
damage to such property while it is in Seller’s possession or control. constitute Seller’s sole and exclusive liability and Buyer’s sole and exclusive remedy
10. Special Tooling. A tooling charge may be imposed for any special tooling, including for infringement of Intellectual Property Rights.
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise,
Such special tooling shall be and remain Seller’s property notwithstanding payment of sales, use, property, occupational or like taxes which may be imposed by any taxing
any charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging authority upon the manufacture, sale or delivery of Products.
to Seller which is utilized in the manufacture of the Products, even if such apparatus 21. Equal Opportunity Clause. For the performance of government contracts and
has been specially converted or adapted for such manufacture and notwithstanding where dollar value of the Products exceed $10,000, the equal employment opportunity
any charges paid by Buyer. Unless otherwise agreed, Seller shall have the right to clauses in Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a),
alter, discard or otherwise dispose of any special tooling or other property in its sole and 60-250.4, are hereby incorporated. 6/09
discretion at any time.
offerofsale.indd, dd
■ Valves or parts thereof thrown off at high speed ■ Contact with fluid that may be hot, cold, toxic or otherwise injurious
■ High velocity fluid discharge ■ Injuries resulting from injection, inhalation or exposure to fluids
■ Explosion or burning of the conveyed fluid ■ Injury from handling a heavy item (dropped, awkward lift)
■ Contact with suddenly moving or falling objects controlled by the Valve ■ Electric shock from improper handling of solenoid connections
■ Injections by high-pressure fluid discharge ■ Injury from slip or fall on spilled or leaked fluid
Before selecting or using any of these Products, it is important that you read and follow the instructions below. In general, the Products are not approved
for in-flight aerospace applications. Consult the factory for the few that are FAA approved.
1.0 GENERAL INSTRUCTIONS
1.1 Scope: This safety guide provides instructions for selecting and using (including assembling, installing and maintaining) these Products. For convenience all items
in this guide are called “Valves”. This safety guide is a supplement to and is to be used in conjunction with the specific Parker catalogs for the specific Valves and/or
accessories being considered for use. See item 1.6 below for obtaining those catalogs.
1.2 Fail-Safe: Valves can and do fail without warning for many reasons. Design all systems and equipment in a fail-safe mode, so that failure of the Valve or Valve
Assembly will not endanger persons or property.
1.3 Safety Devices: Never disconnect, override, circumvent or otherwise disable any safety lockout on any system whether powered by HVD Valves or any motion
control system of any manufacturer. (e.g. Automatic shut-off on a riding lawn mower should the operator get out of the seat).
1.4 Distribution: Provide a copy of this safety guide to each person that is responsible for selecting or using HVD Valve Products. Do not select HVD Valves without
thoroughly reading and understanding this safety guide as well as the specific Parker catalogs for the Products considered or selected.
E
1.5 User Responsibility: Due the wide variety of operating conditions and applications for Valves, HVD and its distributors do not represent or warrant that any
particular Valve is suitable for any specific system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The
user, through its own analysis and testing is solely responsible for:
■ Making the final selection of the Valve
■ Assuring that the user’s requirements are met and that the application presents no health or safety hazards.
■ Providing all appropriate health and safety warnings on the equipment on which the Valves are used.
■ Assuring compliance with all applicable government and industry standards.
1.6 Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional information. See the Parker
publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com , for the telephone numbers of the appropriate technical
service department. For additional copies of this or any other Parker Safety Guide go to www.parker.com and click on the safety button on the opening page. Catalogs
and/or catalog numbers for the various HVD Valve Products can be obtained by calling HVD at 440-366-5100. Phone numbers and catalog information is also
available on the Parker website, www.parker.com .
notes.indd, dd
Piston, bladder and dia- Self-contained with a mo- Standard and custom Parker’s unique IQAN
phragm type accumulators, tor, gear pump, reservoir, hydraulic cylinders for approach combines sturdy,
gas bottles and KleenVent internal valving, load hold industrial and mobile well-tested hardware
reservoir isolators. checks and relief valves. applications. with intelligent, flexible
computing power.
www.parker.com/accumulator www.parker.com/oildyne www.parker.com/hydcyl www.parker.com/iqan
Pressure and return line Solutions for complex cir- Full line of high and low Parker Chelsea leads the
filters enhances machine cuits that include threaded speed motors provides industry for engineering,
life, reduces maintenance cartridge valves integrated power up to 15,000 in-lbs innovation and performance
and lowers costs. into a single manifold. of torque. in auxiliary power systems.
www.parker.com/hydraulicfilter www.parker.com/hcs www.parker.com/pumpmotor www.parker.com/chelsea