Sie sind auf Seite 1von 57

CONSTRUCTION OF VARIOUS BUILDINGS FOR ACHARYA NG RANGA AGRICULTURE

UNIVERSITY AT BAPATLA AND GUNTUR (DISTT. GUNTUR)


SUMMARY SHEET

Amount (in Rs.)


S
Description of Head of work Scheduled (DSR) Non-Scheduled
No. Total
Items Items
1 Civil works 5156,01,948.42 925,51,686.11 6081,53,634.53
2 Water Supply and Sanitary Installations 352,26,952.72 162,24,089.21 514,51,041.93
3 Fire Fighting 4,33,517.53 123,33,611.60 127,67,129.13
4 External & Internal Electrical Works 268,01,975.00 409,42,684.67 677,44,659.67

5 HVAC SYSTEM 49,54,803.09 49,54,803.09


Total 5780,64,393.67 1670,06,874.68 7450,71,268.35
Grand Total (DSR + N. S.) 7450,71,268.35

Say Rs. 74.50 Crores


BoQ ANGRAU - Annexe Bldg. Guntur

CONSTRUCTION OF VARIOUS BUILDINGS FOR ACHARYA N G RANGA AGRICULTURE UNIVERSITY AT BAPATLA AND GUNTUR (DISTT. GUNTUR)

BILL OF QUANTITES
S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR

SUBHEAD - 1 : EARTH WORK


1.1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed
earth to be levelled and neatly dressed. -
1.1.1 2.6.1 All kinds of soil cum 11,475.00 155.60 - 17,85,510.00 -
1.2 2.7 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed
earth to be levelled and neatly dressed. - - - -
1.2.1 2.7.1 Ordinary or Hard Rock cum 2,874.00 244.60 - 7,02,980.40 -
1.3 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soil as directed, within a lead
of 50m. - - - -
1.3.1 2.8.1 All kinds of soil. cum 5,272.00 157.50 - 8,30,340.00 -
1.4 2.9 Excavation work by mechanical means (Hydraulic excavator)/ manual means in
foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soils as directed, within a lead
of 50 m. - - - -
1.4.1 2.9.1 Ordinary rock cum 1,474.00 263.50 - 3,88,399.00 -
1.5 2.1 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50
m - - - -
1.5.1 2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. Rmt 3,050.00 127.55 - 3,89,027.50 -
1.5.2 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Rmt 3,670.00 208.30 - 7,64,461.00 -
1.6 1.1.2 Carriage of material by Mechanical transport including loading & unloading & stacking Cum
upto 3 kms (Earth) 4,183.00 113.29 - 4,73,892.07 -
1.6.1 1.1.4 Carriage of material by Mechanical transport including loading & unloading & stacking cum
upto 3 kms (Rock) 1,320.00 203.22 - 2,68,250.40 -
1.7 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of cum
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift upto 1.5 m 10,971.00 -
112.40 12,33,140.40 -

2 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
1.8 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation / banking cum
excavated or stacked materials - - - -
1.8.1 2.26.1 All kinds of soil cum 1,760.00 46.25 - 81,400.00 -
1.8.2 2.26.2 Ordinary or hard rock cum 660.00 82.95 - 54,747.00 -
1.9 NS Supplying and filling, in plinth with river sand under floors including, watering, cum
ramming consolidating and dressing complete. 2,653.00 307.08 - 8,14,683.24
1.10 2.28 Surface dressing of the ground including removing vegetation and inequalities not
exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m.
- - - -
1.10.1 2.28.1 All kinds of soil 100Sqm 337.00 1,245.75 - 4,19,817.75 -
1.11 2.31 Clearing jungle including uprooting of rank vegetation, grass, bush wood, trees and 100sqm
saplings of girth up to 30cm measured at a height of 1m above ground level and
removing of rubbish up to a distance of 50m outside the periphery of the area cleaned.
180.38 642.00 - 1,15,803.96 -
1.12 NS Credit for Sale and disposal of all kinds of rock cum (1,690.00) 185.25 - (3,13,072.50)
1.13 2.34 Supplying chemical emulsion in sealed containers including
delivery as specified. - - - -
1.13.1 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Lit 3,096.00 185.95 - 5,75,701.20 -
1.14 2.35 Diluting and injecting chemical emulsion for POST CONSTRUCTIONAL anti-termite
treatment (excluding the cost of chemical emulsion)
- - - -
1.14.1 2.35.2 Along the external wall below concrete or masonry apron using chemical emulsion @
2.25 litres per linear metre including drilling and plugging holes etc.: - - - -
1.14.1. 2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Rmt
1 2,730.00 22.70 - 61,971.00 -
1.14.2 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole,
300 mm apart including drilling 12 mm diameter holes and plugging with cement
mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor - - - -
1.14.2. 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm
1 12,531.00 118.90 - 14,89,935.90 -
1.14.3 2.35.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Rmt
Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia
holes at downward angle of 45 degree at 150 mm centre to centre and sealing the
same 1,550.00 200.70 - 3,11,085.00 -
1.15 NS Excavating top soil to a depth of 300mm transportation of the top soil including cum
loading, unloading and stacking upto 1Km and bringing back to project site and
spreading the same as per the direction of EIC 4,702.00 295.20 - 13,88,030.40
TOTAL OF EARTH WORK - - 99,46,462.58 18,89,641.14
2.1 4.1 SUBHEAD - 2 : CONCRETE WORK - - - -
2.1.1 4.1.3 1:2:4 ( 1Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cum
174.00 5,466.30 - 9,51,136.20 -
2.1.2 4.1.5 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) cum
1,410.00 4,834.30 - 68,16,363.00 -
2.1.3 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum
1,167.00 4,301.15 - 50,19,442.05 -
2.1.4 4.1.10 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) cum

108.00 4,004.00 - 4,32,432.00 -


2.2 4.11 Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 sqm
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
1,904.00 314.85 - 5,99,474.40 -

3 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
2.3 4.12 Extra for providing and mixing water proofing material in cement concrete work in per 50
doses by weight of cement as per manufacturer‟s specification Kg of
Cement 1,285.00 48.15 - 61,872.75 -
2.4 4.13 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved sqm
quality using 1.7kg per square metre on damp proof course after cleaning the surface
with brushes and finally with a piece of cloth lightly soaked in kerosene oil
1,767.00 132.00 - 2,33,244.00 -
2.5 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sqm
sand: 6 graded stone aggregate 20mm nominal size) over 75mm bed by dry brick
ballast 40mm nominal size well rammed and consolidated and grouted with fine sand
including finishing the top smooth. 1,972.00 419.30 - 8,26,859.60 -
TOTAL OF CONCRETE WORK - - 149,40,824.00 -
SUBHEAD - 3 : R.C.C WORKS - - - -
3.1 5.1 Providing and laying in position specified grade of reinforced cement concrete,
excluding the cost of centering, shuttering, finishing and reinforcement - All work up to
plinth level : - - - -
3.1.1 5.1.3 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum
204.00 5,725.90 - 11,68,083.60 -
3.2 5.9 Centring and shuttering including strutting, propping etc. and removal of form for:
- - - -
3.2.1 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 4,645.36 196.45 - 9,12,580.97 -
3.2.3 5.9.3 Suspended floors, roofs,landings, balconies and access platform. sqm 23,659.00 401.65 - 95,02,637.35 -
3.2.4 5.9.4 Shelves (Cast in situ) sqm 1,368.00 401.65 - 5,49,457.20 -
3.2.5 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 15,662.10 453.35 - 71,00,413.04 -
3.2.6 5.9.7 Stairs, (excluding landings) except spiral-staircases. sqm 847.00 395.65 - 3,35,115.55 -
3.2.7 5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, sqm
string courses, bands, copings, bed plates, anchor blocks and the like
398.00 196.45 - 78,187.10 -
3.2.8 5.9.16 Edges of slab and breaks in floors and walls. - - - -
3.2.8.1 5.9.16.1 Under 20 cm wide metre 2,168.00 116.40 - 2,52,355.20 -
3.2.9 5.9.19 Weather shade, Chajjas, corbels etc., including edges sqm 1,106.00 492.35 - 5,44,539.10 -
3.2.10 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers.with water proof ply sqm
12 mm thick 18,730.00 423.65 - 79,34,964.50 -
3.3 5.11 Extra for additional height in centering, shuttering where ever required with adequate
bracing, propping etc. including cost of de-shuttering and decentering at all levels,
over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan - - - -
area to be measured)
3.3.1 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm
22,850.00 159.05 - 36,34,292.50 -
3.4 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level. - - - -
3.4.1 5.22.6 Thermo-Mechanically Treated bars kilogram 12,71,952.00 68.10 - 866,19,931.20 -

4 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
3.5 5.22A Reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level. - - - -
3.5.1 5.22A.6 Thermo-Mechanically Treated bars kilogram 12,88,180.00 68.10 - 877,25,058.00 -
3.6 5.30 Add or deduct for plaster drip course/ groove in plastered surface or moulding to mtr
R.C.C. projections. 10,760.00 30.75 - 3,30,870.00 -
3.7 5.33 Providing and laying in position machine batched and machine mixed design mix M-25
grade cement concrete for reinforced cement concrete work, using cement content as
per approved design mix, including pumping of concrete to site of laying but excluding
the cost of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,
improve workability without impairing strength and durability as per direction of
Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement
used as per design mix is payable/ recoverable separately). - - - -
3.7.1 5.33.1 All works upto plinth level cum 1,935.00 6,296.15 - 121,83,050.25 -
3.7.2 5.33.2 All work above plinth level up to floor V level. cum 1,909.00 7,014.55 - 133,90,775.95 -
3.8 5.34 Extra for providing richer mixes at all floor levels: cum 550.00 76.50 - 42,075.00 -
3.8.1 5.34.1 Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement
content considered in M-30 is @ 340 kg/cum) 215.00 76.50 - 16,447.50 -
3.9 5.37 Providing and laying in position ready mixed M-25 grade concrete for reinforced
cement concrete work, using cement concrete as per approved design mix,
manufactured in fully automatic batching plant and transported to site to work in
transit mixer for all leads, having continious agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concerte work, including pumping of
R.M.C from transit mixer to site of laying, excluding the cost of centering, shuttering
finishing and reinforcement, including cost of admixtures in recommended proportions
as per IS:9103 to accelerate/retard setting of concrete, improve workability without
impairing stregnth and durability as per directions of the Engineer-in-charge. (Note :-
Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as
per design mix is payable/recoverableseparately). - - - -
3.9.1 5.37.1 All works upto plinth level cum 7,352.00 6,644.60 - 488,51,099.20 -
3.9.2 5.37.2 All works above plinth level upto floor V level cum 7,198.00 7,363.00 - 529,98,874.00 -
3.10 NS Prroviding and filling in position polyurethane sealant in expansion joints in flooring
over 15mm dia becker rod laid in expanstion joint of flooring (including cost of becker
rod) - - - -
3.10.1 15 x 6mm Mtr 489.00 223.87 - 1,09,472.43
3.11 5.28 Providing and fixing in position 12 mm thick bitumen impregnated fibre board per cm
conforming to IS: 1838, including cost of primer, sealing compound in expansion Depth
joints. per 1,036.00 446.90 - 4,62,988.40 -
3.12 5.29 Providing and fixing sheet covering over expansion joints with iron screws as per 100m
design to match the colour/shade of wall treatment : - - - -
3.12.1 5.29.2 Aluminum fluted strips 3.15mm Thk - - - -
3.12.1. 5.29.2.1 150mm wide Mtr 540.00 330.05 - 1,78,227.00 -
1 22.4
3.13 Providing and placing in position suitable PVC water stops conforming to IS:12200 for
construction/expansion joints between two RCC members and fixed to the
reinforcement with binding wire before pouring concrete etc. complete.
- - - -
3.13.1 22.4.2 Dumb bell with central bulb (180mm wide, 8mm thick) Mtr 588.00 461.15 - 2,71,156.20 -
TOTAL OF R.C.C WORKS - - 3350,83,178.81 1,09,472.43

5 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR

SUBHEAD - 4: BRICK WORK - - - -


4.1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in foundation and plinth in - - - -
4.1.1 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 1,215.00 4,918.65 - 59,76,159.75 -
4.1.2 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5
in superstructure above plinth level up to floor V level inall shapes and sizes in
- - - -
4.1.2 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 475.00 5,426.15 - 25,77,421.25 -
4.3 6.15 Extra for providing and placing in position 2 Nos. 6mm dia M.S. bars at every third sqm
course of half brick masonry 7,150.00 69.50 - 4,96,925.00 -
4.4 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation
7.5 in superstructure above plinth level up to floor five level in : - - - -
4.4.1 6.32.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 375.00 5,455.85 - 20,45,943.75 -
4.5 6.38 Providing and laying autoclaved aerated cement blocks masonry with 100mm/ 200mm cum
thick AAC blocks in super structure above plinth level up to floor V level in cement
mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in
position 2 Nos 6 mm dia M.S. bars at every thirdcourse of masonry work
6,230.00 6,386.95 - 397,90,698.50 -
4.6 6.45 Providing and laying Half brick masonry with fly ash bricks of class designation 10,
conforming to IS : 12894, in super structure above plinth and upto floor V level in
- - - -
4.6.1 6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) sqm 7,150.00 751.10 - 53,70,365.00 -
TOTAL OF BRICK WORK - - 562,57,513.25 -
SUBHEAD - 5 : GRANITE WORK - - - -
5.1 8.2 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and
prepolished) machine cut for kitchen platforms, vanity counters window sills, facias
and similar locations of required size of approved shade,colour and texture laid over
20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated
with white cement, mixed with matching pigment, epoxy touch ups, including rubbing,
curing moulding and polishing to the edge to give high gloss finish etc. complete at all
levels. - - - -
5.1.1 8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble
- - - -
5.1.1.1 8.2.1.1 Area of slab Upto 0.50 sqm sqm 215.00 2,341.55 - 5,03,433.25 -
5.1.1.2 8.2.1.2 Area of slab over 0.50 sqm sqm 189.00 2,463.55 - 4,65,610.95 -
5.1.1.3 8.2.2 Granite of any colour and shade - - - -
5.1.1.4 8.2.2.1 Area of slab upto 0.50 sqm Sqm 82.00 3,866.00 - 3,17,012.00 -
5.1.1.5 8.2.2.2 Area of slab over 0.50 sqm sqm 185.00 3,907.40 - 7,22,869.00 -
5.2 8.3 Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc.
including machine polishing to edge to give high gloss finish etc. complete as per
design approved by Engineer - in- Charge - - - -
5.2.1 8.3.1 Marble Work metre 206.00 136.10 - 28,036.60 -
5.2.2 8.3.2 Granite work metre 109.00 230.55 - 25,129.95 -
5.3 8.4 Extra for fixing marble /granite stone over and above corresponding basic item, in metre
facia and drop of width upto 150 mm with epoxy resin based adhesive including
cleaning etc. complete. 209.00 247.40 - 51,706.60 -

6 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
5.4 8.5 Extra for providing opening of required size & shape for wash basins/ kitchen sink in each
kitchen platform, vanity counters and similar location in marble/granite/stone work
including necessary holes for pillar taps etc. including rubbing and polishing of cut
edges etc. complete. 233.00 386.60 - 90,077.80 -
5.5 8.10 Providing and fixing stone slab table rubbed edges rounded and polished of size 75x50
cm deep and 1.8 cm thick fixed in urinal partion by cutting and chase of appropriate
width with chase cutter and embedding the stone in the chase with epoxy grout or
with cement concrete 1:2:4 1 cement :2 coarse sand : 4 graded stone aggregate 6
mm nominal size) as per direction of Engineer -in charge and finished and smooth.
- - - -
5.5.1 8.10.2 Granite Stone of approved shade sqm 74.00 3,263.50 - 2,41,499.00 -
16.92 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed Sqm
on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4
(1cement:4 coarse sand) with joints 10mm wide filled with same mortar including
ruled pointing etc. complete as per direction of engineer-in charge. 345.00 1,375.20 - 4,74,444.00 -
TOTAL OF MARBLE WORK - - 29,19,819.15 -
SUBHEAD - 6 : WOOD WORK - - - -
6.1 9.1 Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners
of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). - - - -
6.1.1 9.1.1 Second class teak wood Cum 19.50 91,496.90 - 17,84,189.55 -
6.2 9.12 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass Sqm
panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening
for glass panes excluding portion inside rebate shall be measured) 1,791.00 5.80 - 10,387.80 -
6.3 9.21 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-
decorative type, core of block board construction with frame of 1st class hard wood
and well matched commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters - - - -
6.3.1 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm
1,421.00 1,909.55 - 27,13,470.55 -
6.3.2 9.21.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Sqm
piano hinges with necessary screws
342.00 1,482.15 - 5,06,895.30 -
6.4 9.23 Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on sqm
all edges of flush door shutters(over all areaof door shutter to be measured).
1,451.00 365.85 - 5,30,848.35 -
6.5 9.24 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost
of glass excluded) (overall area of door shutter to be measured): - - - -
6.5.1 9.24.1 Rectangular or square. sqm 746.00 139.40 - 1,03,992.40 -
6.6 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be Sqm
measured). 334.00 104.55 - 34,919.70 -
6.7 9.40 Providing and fixing wooden moulded beading to door and window frames with iron
screws, plugs and priming coat on unexposed surface etc.complete - - - -
6.7.1 9.40.1 2nd class teak wood - - - -
6.7.1.1 9.40.1.1 50x12 mm metre 2,557.00 117.95 - 3,01,598.15 -
6.8 9.46 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with
two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs,
etc., wherever necessary complete - - - -

7 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
6.8.1 9.46.2 20 mm dia metre 1,716.50 341.00 - 5,85,326.50 -
9.67 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming
to IS : 363 with necessary screws etc. complete : - - - -
9.67.3 90 mm each 284.00 17.45 - 4,955.80 -
6.9 9.70 Providing and fixing IS: 12817 marked stainless steel butt hinges with stainless steel
screws etc. complete - - - -
6.9.1 9.70.2 100 x 58 x 1.9 each 888.00 89.05 - 79,076.40 -
6.9.2 9.70.3 75 x 47 x 1.8 each 309.00 55.60 - 17,180.40 -
6.9.3 9.70.4 50 x 37 x 1.5 each 2,066.00 33.00 - 68,178.00 -
6.10 9.76 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers each
and a pair of lever handles with necessary screws etc. complete (best make of
approved quality). 386.00 546.40 - 2,10,910.40 -
9.80 Providing and fixing 50 mm bright finished brass cup board or wardrobe each
knob of approved quality with necessary screws. 296.00 48.30 - 14,296.80 -
6.11 9.82 Providing and fixing bright finished brass hanging type floor door stopper with each
necessary screws, etc. complete. (150mm length) 381.00 85.70 - 32,651.70 -
6.12 9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic each
door closer (having brand logo with ISI, IS : 3564, embossed on the body, door
weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double
speed adjustment with necessary accessories and screws etc. complete 222.00 1,043.60 - 2,31,679.20 -
6.13 9.86 Providing and fixing bright finished brass casement stays (straight peg type) with
necessary screws etc. complete - - - -
6.13.1 9.86.2 250 mm weighing not less than 280 gms each 538.00 149.25 - 80,296.50 -
6.13.2 9.86.3 200 mm weighing not less than 240 gms each 285.00 137.65 - 39,230.25 -
6.14 9.96 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating
not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or
shade with nuts and screws etc. complete. - - - -
6.14.1 9.96.2 250 x 16mm each 150.00 189.00 - 28,350.00 -
6.15 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or
shade, with necessary screws etc. complete, - - - -
6.15.1 9.97.2 250x10 mm each 158.00 95.25 - 15,049.50 -
6.15.2 9.97.3 200x10 mm each 171.00 79.25 - 13,551.75 -
6.15.3 9.97.4 150x10 mm each 247.00 65.35 - 16,141.45 -
6.15.4 9.97.5 100x10 mm each 331.00 52.35 - 17,327.85 -
6.16 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less
than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade,
with necessary screws etc. complete : - - - -
6.16.1 NS 150 mm each 193.00 79.25 - 15,295.25
6.16.2 9.100.1 125mm each 605.00 69.80 - 42,229.00 -
6.16.3 9.100.2 100 mm each 539.00 55.10 - 29,698.90 -

8 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
6.17 9.123 Providing and fixing factory made door frame (single rebate) made out of single piece Rmt
extruded solid PVC foam profile with homogenous fine cellular structure having smooth
outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred &
Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent
cement , including fixing the frame to wall with suitable dia & length anchor fastener
as per manufacturer‟s specification and direction of Engineer-in-charge.
1,568.60 377.65 - 5,92,381.79 -
6.18 9.124 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam
profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm.
The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally
extruded on the hinge side of the profile for better screw holding power. The styles
and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted
with primer , all four corners of reinforcement to be welded or sealed. Solid PVC
extruded bidding (push fit type) will be set inside the styles and the rails with a cavity,
to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be
mitred cut and joint with the help of PVC solvent cement & self driven self tapping
screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall
thickness 5 mm &15 mm integrally extruded in the middle of the lock rail & fixed with
styles with the help of PVC solvent cement & self driven self tapping screws of size 100
mm x 8 mm complete as per manufacturer‟s specifications and direction of Engineer-in-
charge. - - - -
6.18.1 9.124.2 Decorative finish (both side wood grained finish) Sqm 481.00 3,330.35 - 16,01,898.35 -
6.19 9.127 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in
gloss/ matt/ suede finish with high density protective surface layer and reverse side of
adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of
aproved quality - - - -
6.19.1 9.127.2 1.0 mm thick. Sqm 2,214.00 676.40 - 14,97,549.60 -
6.20 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/ flush door kg
shutter, including fixing etc. complete as per direction of Engineer-in-charge.
365.00 442.35 - 1,61,457.75 -
6.21 9.136 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in Rmt
rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly
filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated
door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm
(minimum) alround the frame and fixing with dash fastener of approved size and
make, including applying a coat of approved brand fire resistant primer etc. complete
as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
122.00 1,250.05 - 1,52,506.10 -
6.22 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire Sqm
rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved
by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical
styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG
G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and
fixing with necessary stainless steel ball bearing hinges of approved make, including
applying a coat of approved fire resistant primer etc. all complete as per direction of
Engineer-in-charge (panneling to be paid for separately).
43.00 6,268.20 - 2,69,532.60 -
6.23 9.139 Providing and fixing panic bar/ latch (Double point) fitted with a single body, Trim Nos
Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be
approved by the Engineer- in- charge, all complete. 14.00 6,133.20 - 85,864.80 -

9 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
6.24 9.140 Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a
coat of approved primer on one face, and fixed on wooden /steel frame work,
complete as per direction of Engineer-in-charge (Frame work shall be paid for
separately). - - - -
6.24.1 9.140.1 12mm thick commercial ply conforming to IS : 1328 BWR type Sqm 43.00 1,059.20 - 45,545.60 -
6.25 NS Supplying and providing Anchor Bolts of length 150 mm -200 mm of dia 10-12mm Nos
with suitable adhesive to fix the door frames with brick or RCC walls/ Columns etc.
2,126.00 495.29 - 10,52,986.54
6.26 NS Finishing with Melamine polishing on wood including Two or more coats on new works Sqm
which also includes a coat of wood filler, polishing, scaffolding, etc., complete in all
aspects as per instruction of Engineer in charge. 800.00 234.77 - 1,87,816.00
TOTAL OF WOOD WORK - - 119,19,168.79 12,56,097.79
SUBHEAD - 7 : STEEL WORK - - - -
7.1 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square bars etc. including priming coat with approved steel primer all complete
- - - -
7.1.1 9.48.1 Fixed to steel windows by welding Kg 7,112.00 109.00 - 7,75,208.00 -
7.1.2 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. Kg 4,295.00 116.90 - 5,02,085.50 -
7.2 10.2 Structural steel work riveted, bolted or welded in built up sections, trussesand framed kg
work, including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer all complete 1,934.00 73.95 - 1,43,019.30 -
7.3 10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron
and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings
complete, including applying a priming coat of approved steel primer
- - - -
7.3.1 10.5.1 Using M.S. angles 40x40x6 mm for diagonal braces. sqm 72.00 3,073.85 - 2,21,317.20 -
10.11 Providing and fixing factory made ISI marked steel glazed doors, windowsand
ventilators, side /top /centre hung, with beading and all memberssuch as F7D, F4B,
K11 B and K12 B etc. complete of standard rolledsteel sections, joints mitred and flash
butt welded and sash bars tenonedand riveted, including providing and fixing of
hinges, pivots, includingpriming coat of approved steel primer, but excluding the cost
of otherfittings, complete all as per approved design, (sectional weight of onlysteel
members shall be measured for payment).
- - - -
10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 kg
cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm
nominal size) 13,200.00 114.15 - 15,06,780.00 -
10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilatorsand cupboard
with rectangular/ L-Type sections, made of 1.60 mm thickM.S. Sheet, joints mitred,
welded and grinded finish, with profiles ofrequired size, including fixing of necessary
butt hinges and screws andapplying a priming coat of approved steel primer.
- - - -
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 kg
cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm
nominal size) 3,493.00 139.10 - 4,85,876.30 -

10 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
7.4 10.28 Providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels Kg
,plates etc., including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless steel dash
fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side
of waist slab with suitable arrangement as per approval of Engineer-in-charge,( for
payment purpose only weight of stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners etc.).
15,993.00 619.40 - 99,06,064.20 -
7.5 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer, including welding and bolted with special shaped washers etc.
complete. - - - -
7.5.1 10.16.1 Hot finished welded type tubes kg 3,540.00 102.90 - 3,64,266.00 -
7.6 10.18 Providing and fixing circular/hexagonal cast iron or M.S. sheet box for ceiling fan each
clamp of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with
its top surface hacked for proper binding, top lid shall be screwed into the cast
iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the
corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard
drawing . 3,905.00 142.95 - 5,58,219.75 -
7.7 10.25 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing
in position and applying a priming coat of approved steel primer using structural steel
etc.as required - - - -
7.7.1 10.25.2 In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works kg 3,706.00 90.10 - 3,33,910.60 -
7.8 10.26 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing,
balcony railing and staircase railing including applying a priming coat of approved steel
primer. - - - -
7.8.1 10.26.1 M. S. tube kg 2,653.00 104.70 - 2,77,769.10 -
10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows &doors with
M.S. Flat 15x3 mm and nuts & bolts complete. - - - -
10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and1.4 mm aperture on Sqm
both sides 646.00 1,277.60 - 8,25,329.60 -
TOTAL OF STEEL WORK - - 158,99,845.55 -
SUBHEAD - 8 : FLOORING - - - -
8.1 11.5 62mm thick cement concrete flooring with concrete hardener topping under layer 50 sqm
mm thick cement concrete 1:2:4 (1 cement :2 coarse sand:4 graded stone aggregate
20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2
(1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume.
Hardening compound of is mixed @ 2 litre per 50kg of cement or as per manufacturers
specifications. This includes cost of cement slurry, but excluding the cost of nosing of
steps etc. complete. 1,187.00 588.90 - 6,99,024.30 -
8.2 11.6 Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (1 cement : 3
coarse sand) finished with a floating coat of neat cement. - - - -
8.2.1 11.6.1 18 mm thick sqm 218.50 377.25 - 82,429.13 -
8.3 11.13 Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. - - - -
8.3.1 11.13.1 40 mm wide and 4 mm thick metre 445.00 50.05 - 22,272.25 -
8.4 11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble
approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar
1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including
rubbing and polishing complete with - - - -
8.4.1 11.23.5 Udaipur green marble sqm 826.00 1,757.60 - 14,51,777.60 -

11 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
8.5 11.24 Extra for pre finished nosing to treads of steps of marble stone. metre 265.00 274.90 - 72,848.50 -
8.6 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to sqm
2.00 metre . 220.00 320.30 - 70,466.00 -
8.7 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with
grey cement slurry mixed with pigment to match the shade of the slab including
rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse
sand) - - - -
8.7.1 11.26.1 25 mm thick sqm 325.00 1,141.40 - 3,70,955.00 -
8.8 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 sqm
mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
207.00 1,191.25 - 2,46,588.75 -
8.9 NS Providing and fixing 1st quality Rectified Ceramic glazed wall tiles conforming to sqm
IS:15622 of approved make in all colours, shades, of 300 x 450 x 6mm size as
approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm
thick bed of Cement Mortar 1:3 (1 Cement :3 Coarse sand) and jointing with grey
cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with
pigment of matching shade complete.
3,312.00 941.06 - 31,16,790.72
8.10 NS Providing and laying Rectified Ceramic glazed floor tiles 600X600 mm 10mm Thk. sqm
of 1st quality conforming to IS : 15622 of approved make in colours such as White,
Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:3 (1 Cement : 3
Coarse sand) including pointing the joints with white cement and matching pigment
etc. complete.
1,450.00 1,129.27 - 16,37,441.50
8.11 NS Providing and laying vitrified floor tiles in different sizes with water absorptions less
than 0.08% and conforming to IS:15622 of approved make in all colours and shades,
laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting
the joints with white cement and matching pigments etc. complete.

- - - -
8.11.1 Size of Tile 600x600 mm 10mm Thick Sqm 18,329.00 1,392.72 - 255,27,164.88
8.12 N.S Granite Stone flooring with 18mm thick granite stone (sample of granite shall be
approved by Engineer -In charge) over 20mm (average) thick base of cement motor
1:3 (1 Cement : 3 Coarse sand) laid and jointed with grey cement slurry including
rubbing & polishing at all levels
- - - -
8.12.1 Area of slab upto & over 0.5 Sqm Sqm 2,823.00 3,992.08 - 112,69,641.84
8.13 N.S Granite Stone in skirting with 18mm thick granite stone (sample of granite shall be
approved by Engineer -In charge) over 20mm (average) thick base of cement motor
1:3 (1 Cement : 3 Coarse sand) laid and jointed with grey cement slurry including
rubbing & polishing at all levels
- - - -
8.13.1 Area of slab upto & over 0.5 Sqm Sqm 579.00 3,972.26 - 22,99,938.54
8.14 11.47 Providing and laying vitrified tiles in different sizes (thickness to be specified by the
manufacturer) with water absorptions less than 0.08% and conforming to IS:15622 of
approved brand & manufacturer in all colours and shade, in skirting, risers of steps,
laid with cement based high polymer modified quick set tile adhesive (water based)
conforming to IS: 15477 in average 6 mm thickness including grouting of joints
(payment of grouting the joints to be made separately).
- - - -
8.14.1 11.47.2 Size of Tile 600x600 mm Sqm 1,260.00 1,371.97 - 17,28,682.20

12 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
TOTAL OF FLOORING WORK - - 30,16,361.53 455,79,659.68
SUBHEAD - 9 : ROOFING - - - -
9.1 12.2 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cemment : 2 course sand : 4
stone aggregate 10mm & down gauge) including finishing with cement mortar 1:3 (1
cement : 3 fine sand) as per standard design. - - - -
9.1.1 12.21.1 In 75 x 75 mm deep chase metre 3,210.00 143.10 - 4,59,351.00 -
9.2 NS Providing and fixing of false ceilings at all heights of 600 mm x 600 mm x 16 mm sqm
ARMSTRONG Mineral Fibre based Acoustic ceiling/wall tiles of type Prima Dune Premier-
Beveled Tegular Edge RH-99 laid on Armstrong 15mm exposed grid system. The frame
work comprises of main runner spaced at1200 mm centers securely fixed to the
structural soffit by approved hangers at 1200 mm maximum centers. Hangers (GI wire
of 4.0 mm dia ) to be fixed by approved roof plug, level adjusters and screws etc. The
last hanger at the end of each main runner should not be greater than 450 mm from
the adjacent wall. Flush fitting 1200mm long cross tees (with double stitching) to be
inter locked between main runners at 600 mm centers to form 1200x600mm modules.
Cut cross tees longer than 600mm to be supported independently. 600mmx600mm
modules to be formed by fitting 600 mm long flush fitting cross tees centrally between
the 1200m cross tees.
2,444.00 2,343.73 - 57,28,076.12
9.3 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete each
1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate of 20 mm nominal size)
over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1
cement :3 coarse sand) and a coat of neat cement rounding the edges and making
and finishing the outlet complete 158.00 186.65 - 29,490.70 -
TOTAL OF ROOFING WORK - - 4,88,841.70 57,28,076.12

13 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR

SUBHEAD - 10 : WATER PROOFING - - - -


10.1 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C., kitchen and the like consisting of: - - - -
10.1.1 (i)Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing sqm
compound conforming to IS 2645 in recommended proportions including rounding off
junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with
water proofing compound in recommended proportion including rounding off junction
of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm
of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should
be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 1,582.00 522.90 - 8,27,227.80 -
10.2 22.7 Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc.
consisting of following operations.
- - - -
10.2.1 a) Applying a slurry coat of neat cement using 2.75 Kg/sqm of cement admixed
with water proofing compound conforming to IS:2645 and approvrd by Engineer-in-
charge over the R.C.C. slab including adjoining walls upto 300mm height including
cleaning the surface before treatment.
- - - -
10.2.1. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size
1 with 50% of cement mortar 1:5 (1 cement:5 Coarse sand ) admixed with water
proofing compound conforming to IS:2645 and approved by Engineer - in -charge
over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement:5 Coarse sand )
admixed with water proofing compound conforming to IS:2645 and approved by
Engineer-in-charge to required slope and treating similarly the adjoining walls upto
300mm height including rounding of junctions of walls and slabs.
- - - -
10.2.1. c) After two days of proper curing applying a second coat of cement slurry using 2.75
1.2 km/ sqm of cement admixed with water proofing compound conforming to IS:2645
and approved by Engineer-in-charge
- - - -
10.2.1. d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement
1.3 : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge including laying glass fibre cloth of approved quality
in top layer of plaster and finally finishing the surface with trowel with neat cement
slurry and making pattern of 300x300mm square 3mm deep.
- - - -
10.2.1. e) The whole terrace so finished shall be flooded with water for a minimum period of
1.4 two weeks for curing and for final test. All above operations to be done in order and
as directed and specified by the Engineer -in-charge.
- - - -
10.2.1. 22.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm. sqm
1.5 13,495.00 1,019.05 - 137,52,079.75 -
10.3 4.12 Extra for providing and mixing water proofing material in cement concrete work in per 50
doses by weight of cement as per manufacturer‟s specification. kg
cement 2,014.00 48.15 - 96,974.10 -
TOTAL OF WATER PROOFING WORK - - 146,76,281.65 -

14 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR

SUBHEAD - 11 : FINISHING - - - -
11.1 13.1 12 mm cement plaster on even side of Masonery work with mix of : - - - -
11.1.1 13.1.1 1:4(1 cement : 4 fine sand) sqm 42,256.00 163.35 - 69,02,517.60 -
11.2 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : - - - -
11.2.1 13.2.1 1:4(1 cement : 4 fine sand) sqm 30,995.00 189.40 - 58,70,453.00 -
11.4 13.6 20 mm cement plaster of mix : - - - -
11.4.1 13.6.1 1:4 (1 cement: 4 coarse sand) sqm 26,107.00 242.05 - 63,19,199.35 -
11.5 13.16 6 mm cement plaster of mix - - - -
11.5.1 13.16.1 1:3 (1 cement : 3 fine sand) sqm 25,548.00 134.70 - 34,41,315.60 -
11.6 13.21 Extra for providing and mixing water proofing material in cement plaster work in per bag
proportion recommended by the manufacturers. of 50kg.
Cement
used in
the mix 1,718.14 50.65 - 87,023.79 -
11.7 NS Finishing walls with textured exterior finished "Unitile/Stone Castle" or equivalent in sqm
required shade applied as for manufactures specifications. 675.00 652.80 - 4,40,640.00
11.8 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of
required shade - - - -
11.8.1 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm. over and including base coat sqm
of water proofing cement paint applied @ 2.20 kg/10 sqm). 17,997.00 94.95 - 17,08,815.15 -
11.9 13.80 Providing and applying white cement based putty of average thickness 1 mm, of sqm
approved brand and manufacturer, over the plastered wall surfaceto prepare the
surface even and smooth complete. 91,085.00 89.65 - 81,65,770.25 -
11.10 13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and
manufacture, including applying additional coats wherever required to achieve even
shade and colour - - - -
11.10.1 13.83.2 Two coats Sqm 83,296.00 75.35 - 62,76,353.60 -
11.11 13.84 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound)
content less than 150 grams/ litre, of approved brand and manufacture, including
applying additional coats wherever required to achieve even shade and colour.
- - - -
11.11.1 13.84.2 Two coats Sqm 5,491.00 71.60 - 3,93,155.60 -
11.12 NS Providing and fixing cement concrete designer tiles 15-20mm thickness, of sqm
approved make and colour laid over 12 mm thick (average) base of cement mortar 1:3
(1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sq.m
including pointing in white cement mixed with pigment of matching shade, as per
manufactures instructions and as directed by the Engineer-in-charge
265.00 1,238.24 - 3,28,133.60
11.13 NS Providing & fixing 24 gauge Chicken wire mesh on joints of RCC & Brick work before Sqm
plastering including nails, at all levels, heights, etc., complete as per the direction of
Engineer-in-charge. 1,074.00 118.50 - 1,27,269.00
11.14 13.22 Extra for plastering exterior walls of height more than 10 m from ground level for sqm
every additional height of 3 m or part thereof. 4,539.00 37.95 - 1,72,255.05 -
11.15 NS Providing and finishing walls of stairs & corridors with San Marco or equivalent texture sqm
paint as per manufaxturer's specification. 285.00 652.80 - 1,86,048.00

15 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
11.16 11.53 Providing and fixing Glass mossaic tiles at finished plain wall surface of size 20 mm x sqm
20 mm x 4 mm in all colour, design , fixing in customize design as per direction of
Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the
help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the
same. The rate is inclusive of all operation, material and required pattern approved by
Engineer-in-Charge 405.00 1,752.60 - 7,09,803.00 -
TOTAL OF FINISHING WORK - - 400,46,661.99 10,82,090.60
SUBHEAD - 12 : ALUMINIUM AND GLAZING WORKS - - - -
12.1 NS Providing and fixing FRAMELESS GLASS INTERNAL PARTITIONS forming a cabin with sqm
10mm thick clear toughened glass with division as shown in drawing and height as
per elevation drawings. All patch fittings and other accessories with approved make
S.S. fittings of S.S.-304 grade as per drawing. All the glass shall be fixed with S.S.
fittings to the adjoining members/ Glass/ Brick/ RCC with fixing clips including filling
up necessary gaps at junction, top, bottom and sides with required weather silicon
sealant. The complete installation of glazing shall be as per drawings or as directed by
Engineer- in- charge and as per the site conditions. Minimum two rows of spider to be
provided to every vertical support The installation of glass partition with stainless steel
fixtures shall be along with approved grade of silicon sealant of "Dow corning - USA"
or "WACKER - Germany". The partition shall be aligned for the entire height and for
the entire width by laser beam equipment to ensure 100 percent 'X' axis and 'Y' axis
alignment. The complete design fixing details, spider fittings, details/ design will be
done as per approval of Engineer-in charge. (The work is to be got executed by
approved specialized agency approved by Engineer in charge.) Swing door systems
with 10 mm thick toughened glass provided and fixed with internal partitions shall be
measured and paid for separately under relevant head. 150.00 7,082.71 - 10,62,406.50
12.2 NS Supply and fixing of UPVC glazed window and ventilator made out of hollow multi-
chambered UPVC sections having isolated drainage and reinforced with galvanized
steel. The corners and joints shall be mitre cut and fusion welded. The outer frame of
the window shall be made out of UPVC sections having an overall size of
60mmx60mmx40mm having wall thickness of 2.3mm, + or - 0.3mm and provided
with steel reinforcement at a hardware location and size of 27mmx21.5mm. The fixed
mullion shall be made out of UPVC sections having an overall size of
76mmx60mmx36mm having wall thickness of 2.3mm, + or - 0.3mm including fixing
of 4mm thick float glass panes. - - - -
12.2.1 Windows sqm 2,710.00 7,815.75 - 211,80,682.50
12.2.2 Ventilators sqm 210.00 5,210.50 - 10,94,205.00
12.3 NS Providing and fixing 6 mm thick Orion Blue Solar Control &Thermal Insulated Glass of sqm
Saint Gobain or equivalent in windows including necessary fittings, etc., complete in all
respects. 65.00 2,224.86 - 1,44,615.90

16 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
12.4 21.1 Providing and fixing anodised aluminium work for doors, windows, ventilators, and
partitions with extruded built up standard tubular and other section of approved make
conforming to IS:733 and IS: 1285, anodized transparent or dyed to required shades
according to IS: 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs
and screws or with fixing clips, or with expansion hold fasteners including necessary
filling up of gaps at junction at top, bottom and sides with required PVC / neoprene
felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap beading for
glazing/paneling, C.P brass/stainless steel screws all complete as per architectural
drawing and direction of Engineer in charge (Glazing and Paneling to be paid for
separately).

- - - -
12.4.1 21.1.1 For fixed Portion - - - -
12.4.1. 21.1.1.1 Anodised aluminium (anodised trasparent or dyed to required shade acording to is kg
1 1868 , minium anodic coating of grade AC 15) 1,335.00 348.50 - 4,65,247.50 -
12.4.2 21.1.2 For shutters of door, windows & ventilators including providing and fixing hinges /pivot
and making provision for fixing of fittings wherever required including the cost of
PVC/Neoprene gasket required (Fittings shall be paid for separately.)
- - - -
12.4.2. 21.1.2.1 Anodised aluminium (anodised trasparent or dyed to required shade acording to is kg
1 1868 , minium anodic coating of grade AC 15)
1,285.00 405.90 - 5,21,581.50 -
12.5 21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer
or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling
fixed in aluminum doors, windows shutters and partition frames with C.P. brass /
stainless steel screws etc. complete as per architectural drawings and directions of
engineer-in-charge. - - - -
12.5.1 21.2.2 Pre-laminated particle board with decorative lamination on both sides Sqm 472.00 1,089.75 - 5,14,362.00 -
12.6 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the
architectural drawings and the directions of engineer-in-charge. - - - -
12.6.1 21.3.2 With float glass panes of 5.50 mm thickness sqm 336.00 1,054.20 - 3,54,211.20 -
12.7 26.1 Providing and supplying aluminium extruded tubular and other aluminium sections as Kg
per the architectural drawings and approved shop drawings, the aluminium quality as
per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-
80 microns conforming to AAMA 2604 of required colour and shade as approved by the
Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws
etc.necessary for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account). 385.00 338.25 - 1,30,226.25 -
12.8 21.4 Providing and fixing double action hydraulic floor spring of approved brand and
manufacture IS : 6315 marked, for doors including cost of cutting floors as required,
embedding in floors and cover plates with brass pivot and single piece M.S. sheet
outer box with slide plate etc. complete as per the direction of Engineer-in-chargs.
- - - -
12.8.1 21.4.1 With stainless steel cover plate each 66.00 2,039.00 - 1,34,574.00 -
12.9 21.16 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS
screws etc .complete as per direction of Engineer-in-Charge. - - - -
12.9.1 21.16.1 Anodized (AC 15 ) aluminium each 72.00 65.60 - 4,723.20 -
12.10 21.13 Providing and fixing 100 mm brass locks (best make of approved quality) for each
aluminium doors including necessary cutting and making good etc. complete. 69.00 418.65 - 28,886.85 -

17 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
12.11 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to required kg
shade according to IS:1868. Minimum anodic coating of grade AC 15) sub frame work
for windows and ventilators with extruded built up standard tubular sections of
approved make conforming to IS:733 and IS:1285 fixed with rawl plugs and stainless
steel screws etc. 315.00 312.20 - 98,343.00 -
12.12 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer rod of approved quality as per
architectural drawings and direction of Engineer-in-charge complete.
- - - -
12.12.1 21.8.1 Upto 5mm depth and 5 mm width metre 740.00 88.75 - 65,675.00 -
21.17 Providing and fixing anodised aluminium grill (anodised transparent or dyed to Kg
required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of
approved design/pattern, with approved standard section and fixed to the existing
window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre,
including cutting the grill to proper opening size for fixing and operation of handles and
fixing approved anodised aluminium standard section around the opening, all complete
as per requirement and direction of Engineer-in-charge. (Only weight of grill to be
measured for payment). 15,963.00 403.35 - 64,38,676.05 -
21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved Sqm
brand and manufacture, including providing and fixing top & bottom pivot & spring
type fixing arrangement and making necessary holes etc. for fixing required door
fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and
stopper etc.to be paid separately).
170.50 4,746.25 - 8,09,235.63 -
12.13 N.S Providing 6mm thick Orion Blue Solar control & Thermal insulated Glass of Saint Sqm
Gobain or equivelant in windows 483.00 2,224.86 - 10,74,607.38
12.14 Providing and fixing 100 mm brass locks (best make of approved quality) for Nos
NS aluminium doors including necessary cutting and making good etc. complete in all
respects. 87.00 6,328.88 - 5,50,612.56
TOTAL OF ALUMINIUM WORK - - 95,65,742.18 251,07,129.84
SUBHEAD - 13 : MISCELLANEOUS WORKS - - - -
13.1 6.44 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay metre
F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement
mortar 1:4 (1 cement : 4 fine sand). 3,113.00 38.15 - 1,18,760.95 -
13.2 NS Providing and fixing fire hose cabinet door 1200x1500 mm with 40x75x14 gauge kg
pressed steel door frame with 25x5x100 mm M.S. holdfast fixed in concrete block in
masonry, including shutters of 40x75x14 gauge pressed steel stiles including 4 mm
thick clear glass fixed with 12x12 mm M.S. beading, fixing 75x40 mm brass hinges,
Welding a 40x6mm M.S. flat on the right shutter, including 2 coats of approved steel
primer and synthetic enamel paint of approved quality and shade, complete as per
drawing. 295.00 3,467.06 - 10,22,782.70
13.3 5.18 Providing, precast cement concrete Jali 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 6mm nominal size) reinforced with 1.6mm dia mild steel wire
including centering and shuttering, roughening, cleaning, fixing and finishing in cement
mortar 1:3 (1 cement : 3 fine sand) etc. complete excluding plastering of the jambs,
sills and soffits. - - - -
13.3.1 5.18.2 40mm thk Sqm 290.00 638.90 - 1,85,281.00 -
13.4 NS Providing and fixing Polycarbonate sheet vault with fixing system specified by Sqm
manufacturer and EPDM Gasket with MS Hollow Section with necessary anchoring
accessories. (Dia:6m,Ht.:3m): with 3mm thick Compact Clear/Bronze (PT-1003/2003)
Polycarbonate sheet and MS supporting structure including primer and enamel painting
etc., at all levels and heights, complete and approved by Engineer-in-Charge. (The
work shall be carried out by approved and specialised agency) (Plan area to be
measured for payment) 1,539.00 5,095.59 - 78,42,113.01
18 Signature of Contractor with Seal/ Stamp
BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
13.5 NS Providing, supplying, laying and fixing Bethamchelra stone cladding on cement mortar Sqm
1:3 as approved by the architect on elevation as per the drawing including lead, lift,
necessary scaffolding, at all heights, levels, etc., complete in all aspects.
735.00 3,219.42 - 23,66,273.70
13.6 NS Providing, supplying and fixing Terracotta Jali as per pattern mentioned in the Sqm
architectural drawing including finishing, necessary scaffolding, at all heights, levels,
etc., complete as per instruction of Engineer in charge.
765.00 742.94 - 5,68,349.10
13.7 4.6 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings
etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement
:3 coarse sand) including the cost of required centring, shuttering and finishing
smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on surfaces
complete. - - - -
13.7.1 4.6.1 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum
94.00 5,714.95 - 5,37,205.30 -
TOTAL OF MISCELLANEOUS WORK 8,41,247.25 117,99,518.51
TOTAL OF CIVIL WORKS CARRIED OVER TO SUMMARY SHEET 5156,01,948.42 925,51,686.11
WATER SUPPLY & SANITARY INSTALLATIONS
SUBHEAD - 14 SANITARY INSTALLATIONS
14.1 17.1 Providing and fixing water closet squatting pan (Indian type WC pan) with 100mm
sand cast Iron P or S Trap, 10 litre low level white PVC flushing cistern with manually
controlled device (handel lever), conforming to IS 7231, with all fittings & fixtures
complete including cutting and making good the walls and floors wherever required.
-
14.1.1 17.1.1 White vitreous china Orissa pattern WC pan of size 580 x 440mm with intergal type Each
foot rests. 78.00 3,392.80 - 2,64,638.40 -
14.2 17.2 Providing and fixing white vitreous china pedestal type water closet (European type)
with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe, with
manually controlled device (handle lever), conforming toIS: 7231, with all fittings and
fixturescomplete, including cutting and making good the walls and floors wherever
required: - - - -
14.2.1 17.2.1 E.W.C. pan with ISI marked white solid plastic seat and lid Each 261.00 3,317.30 - 8,65,815.30 -
14.3 NS Less for not providing 5 Ltr PVC Automatic flushing cistern and CP brass spreaders incl. Each Set
flush pipe 233.00 (1,020.00) - (2,37,660.00) -
14.4 NS Providing and fixing hand shower (Health Faucet) with 15 mm dia., 1 m long PVC Each
tube and wall hook all complete of make Jaquar or equivalent. 220.00 1,310.55 - 2,88,321.00
14.5 17.34 Providing and fixing toilet paper holder : - - - -
14.5.1 17.34.1 C.P. brass Each 218.00 415.90 - 90,666.20 -
14.6 17.5 Fixing white vitreous china flat back half stall urinal : - - - -
14.6.1 17.5.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern Each 134.00 6,591.10 - 8,83,207.40 -
14.7 17.76 Providing and fixing, Testing & Commissioning of PTMT urinal cock of approved
quality and colour. - - - -
14.7.1 17.76.1 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female Each
threads weighing not less than 48 gms 134.00 156.05 - 20,910.70 -
14.8 NS Supply, Installation, Testing & Commissioning of UNDER COUNTER WASH BASIN of Each
model number :CNS-WHT-703 (410x505X185) (JAQUAR) or approved equivalent
make .(Oval Shape) 297.00 1,684.00 - 5,00,148.00
14.9 NS Supply, Installation, Testing & Commissioning of 15 mm nominal bore Pillar Cock Each
long neck with aerator of Model Jaquar CON 021 KN or approved make conforming to
IS:8931 complete with Supporting Accessories etc. 299.00 1,233.28 - 3,68,750.72

19 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
14.10 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32
mm C.P. brass waste of standard pattern, including painting of fittings and brackets,
cutting and making good the walls wherever
require: - - - -
14.10.1 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass Each
pillar taps 36.00 2,331.15 - 83,921.40 -
14.11 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality
and colour. - - - -
14.11.1 17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than Each
45 gms 331.00 113.95 - 37,717.45 -
14.12 17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less Each
than 60 gms 60.00 144.15 - 8,649.00 -

20 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
14.13 18.58 Providing and fixing PTMT grating of approved quality and colour. - - - -
14.13.1 18.58.1.1 Circular type, 100 mm nominal dia Each
208.00 49.25 - 10,244.00 -
14.14 18.58.1.2 Circular type,125 mm nominal dia with 25 mm waste hole Each
185.00 57.35 - 10,609.75 -
14.14.1 18.58.2 Rectangular type with openable circular lid
- - - -
14.14.1 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round Each
.1 213.00 150.30 - 32,013.90 -
14.15 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions :
- - - -
14.15.1 18.21.1 30 cm length
- - - -
14.15.1 18.21.1.1 15 mm nominal bore Each
.1 358.00 60.10 - 21,515.80 -
14.16 17.32 Providing and fixing mirror of superior glass (of approved quality) and of required
shape and size with plastic moulded frame of approved make and shade with 6 mm
thick hard board backing : - - - -
14.16.1 17.32.3 Oval shape 450x350 mm (outer dimensions) Each 78.00 783.95 - 61,148.10 -
14.16.2 17.32.4 Rectangular shape 1500x450 mm. Each 98.00 1,332.45 - 1,30,580.10 -
14.17 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen/ Laboratory sink as per
IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of
fittings and brackets, cutting and making good the walls wherever required
- - - -
14.17.1 17.10.1.2 510x1040 mm bowl depth 225 mm Each 21.00 6,779.20 - 1,42,363.20 -
14.18 17.11 Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass
chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with
necessary C.P. brass unions complete, including
painting of fittings and brackets, cutting and making good the wall wherever required
- - - -
14.18.1 17.11.2 Size 600x450x200 mm Each 15.00 3,162.75 - 47,441.25 -
14.19 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink. - - - -
14.19.1 17.70.2 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mm Each
single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from
the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal,
weighing not less than 263 gms 353.00 518.15 - 1,82,906.95 -
14.20 17.71 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and Each
112mm distance from wall of standard shape with bracket of the same materials with
snap fittings of approved quality and colours weighing not less than 105 gms
401.00 228.85 - 91,768.85 -
14.21 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide Each
with minimum distances of 37 mm from wall face with concealed fittings arrangement
of approved quality and colour, weighing not less than 88 gms. 242.00 218.50 - 52,877.00 -
14.22 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
- - - -
14.22.1 18.49.1 15 mm nominal bore Each 36.00 459.50 - 16,542.00 -
14.23 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming
to IS standards and weighing not less than 690 gms. - - - -
14.23.1 18.51.1 15 mm nominal bore Each 273.00 610.65 - 1,66,707.45 -
14.24 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of
approved make conforming to IS:8931. - - - -
14.24.1 18.52.1 15 mm nominal bore Each 582.00 619.75 - 3,60,694.50 -
21 Signature of Contractor with Seal/ Stamp
BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
14.25 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of
approved quality conforming to IS:8931 a) 15 mm nominal bore - - - -
14.25.1 18.53.1 15mm nominal bore Each 460.00 507.70 - 2,33,542.00 -
14.26 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth Each
102mm, height of 75mm with concealed fitting arrangements, weighing not less than
106 gms. 356.00 164.95 - 58,722.20 -
14.27 NS Providing and fixing straight type Macfit single body push fit type WC pan connector Each
with factory supplied spring loaded seal guard of McAlpine, UK with integral single
mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I.
Pipe as supplied with the pan connector. 220.00 541.85 - 1,19,207.00
14.28 NS Providing & Fixing of Grab Bar size 300mm long in handicap toilet complete as Each
required.Makes & Model No.Jaquar AKP-35701P or
Equivalent. 31.00 1,692.92 - 52,480.52
14.29 NS Providing & Fixing Hand drier in ruwgd multiple stobed, multiple steel enclouser with
one bracket for firm wall fixture, Im sheathed three coat flexible cable with 3 pin 15 A
plugs top along with lock & key and of shed approved by Engineer - - - -
14.29.1 No touch operation - - - -
14.29.1 suitable for operation on 230v 50Hz 15A outlet Ac supply each
.1 22.00 12,194.16 - 2,68,271.52
14.30 NS Providing & Fixing C.P. Brass Twin Robe Hooks each 147.00 547.80 - 80,526.60
14.31 NS Providing & fixing Sink cock with regular swinging spout (wall mounted) with wall each
flange 34.00 1,981.18 - 67,360.12
Supply, Installation, Testing & Commissioning of Overhead Shower ø140mm Each
Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with
Rubit Cleaning System of model Jaquar OHS-1757 or approved equivalent design/
NS model and quality including cutting and making good complete as required along with
Shower Arm ø20mm & 450mm Long Round Shape with 90° Bend For Wall Mounted, (
Jaquar SHA-479L450 or approved equivalent model) Shower Head, complete with
Supporting Accessories etc.
47.00 5,145.12 - 2,41,820.64
Supply, Installation, Testing & Commissioning of 15 mm nominal bore Single Lever Each
Sink Mixer With Swinging Spout on Upper Side (Wall Mounted Model) With
NS
Connecting Legs & Wall Flanges of Model Jaquar ARI-CHR-39165 or approved
equivalent model 12.00 4,952.95 - 59,435.40
Supply, Installation, Testing & Commissioning of Wall Mixer Non-Telephonic Each
NS Shower Arrangement with Connecting Legs & Wall Flanges of Model No. Jaquar CON-
219KN or approved equivalent model 47.00 3,862.31 - 1,81,528.57
TOTAL FOR SUB HEAD - 14 - - 36,37,542.90 22,27,850.09
SUBHEAD - 15 DRAINAGE INSTALLATIONS - -
15.1 Providing and fixing soil, waste and vent pipes : - -
15.1.1 NS 75 MM Internal/ External Waste Water PVC Line - -
15.1.1. Supply, Installation, Testing & Commissioning of 75mm OD 6KG/Sq.cm Internal & Rmt
1 External Waste Water PVC (SWR) pasted pipe at site using Solvent Cement ISI
Marked [As per IS 4985] along with Heavy duty ISI Marked inspection eyes PVC
fittings, Ts, Elbows, Bends, Ys etc. Adapters, Air vents, Clamping with GI U Clamps as
required for firmly installing the pipes. Testing of the system for leakage and Air
tightness etc complete. 3,535.00 490.34 - 17,33,351.90
15.2 NS 110 MM Internal/ External Soil Waste PVC Line - - - -

22 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
15.2.1 Supply, Installation, Testing & Commissioning of 110mm OD 6KG/Sq.cm Internal & Rmt
External Soil/ Waste Water PVC (SWR) pasted pipe at site using Solvent Cement ISI
Marked [As per IS 4985] along with Heavy duty ISI Marked PVC fittings, Ts, Elbows,
Bends, Ys etc. Adapters, Air vents, Inspection Eyes, Clamping with GI U Clamps as
required for firmly installing the pipes. Testing of the system for leakage and Air
tightness. 2,163.00 594.35 - 12,85,579.05
15.3 NS VENT PIPING - - - -
15.3.1 Supply, Installation, Testing & Commissioning of 75 mm OD 4KG/Sq.cm External Rmt
Vent PVC pasted pipe at site using Solvent Cement ISI Marked [As per IS 4985] with
Heavy duty ISI Marked PVC fittings, Ts, Elbows, Bends, Ys etc. Adapters, Air vents,
Clamping with GI U Clamps as required for firmly installing the pipes. Testing of the
system for leakage and Air tightness. 1,158.00 396.24 - 4,58,845.92
15.4 NS Providing and fixing GI clamps of approved design and making good the walls etc.
- - - -
15.4.1 For 110mm dia. Pipe Each 663.00 49.53 - 32,838.39
15.4.1. For 75mm dia. Pipe Each
1 843.00 39.62 - 33,399.66
15.5 NS Providing & fixing of epoxy coated 25 mm thick C.I. Grating with frame for channel
drains including all accessoreis complete - - - -
15.5.1 350 wide No. 26.00 262.70 - 6,830.20
15.6 NS S.W.V. Fittings
- - - -
15.6.1 NS Coupler - - - -
15.6.1. size 80mm (3") each
1 350.00 69.34 - 24,269.00
15.6.1. size 100mm (4") each
2 197.00 94.11 - 18,539.67
15.7 NS Bend 45 degree - - - -
15.7.1 size 100mm (4") each 126.00 66.37 - 8,362.62
15.7.1. size 80mm (3") each
1 136.00 51.51 - 7,005.36
15.8 NS Swept door bend - - - -
15.8.1 size 100mm (4") each 131.00 138.68 - 18,167.08
15.8.1. size 80mm (3") each
1 133.00 94.11 - 12,516.63
15.9 NS Swept door tee - - - -
15.9.1 size 100mm (4") each 127.00 217.93 - 27,677.11
15.9.1. size 80mm (3") each
1 133.00 188.21 - 25,031.93
15.10 NS Reducing tee - - - -
15.10.1 size 100x50mm (4"x2") each
103.00 128.78 - 13,264.34
15.11 NS Female threaded Adapter - - - -
15.11.1 size 40mm (1.5") each
103.00 59.44 - 6,122.32
15.12 NS Reducing whye - - - -
15.12.1 size 100x50mm (4"x2") each
115.00 178.31 - 20,505.65
15.13 NS Female threaded elbow - - - -
23 Signature of Contractor with Seal/ Stamp
BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
15.13.1 size 40mm (1.5") each
103.00 89.15 - 9,182.45
15.14 NS Multi trap - - - -
15.14.1 Size 100x80x50 each
739.00 188.21 - 1,39,087.19
15.15 NS Vent cowl - - - -
15.15.1 Size 80mm (3") each
270.00 84.20 - 22,734.00
15.16 NS Supplying and fixing of PVC Nahani Trap not less than 75mm 4 way / 2 way each
(Superior variety) having minimum of water seal of 50mm confirm to relevant I.S.
specifications with its latest amendments including resting on the bed of brick jelly
concrete 1:5:10 (One of cement, five of sand & ten of 40 mm gauge brick jelly) etc.,
complete complying with relevant standard specification and as directed by the
departmental officers (The PVC Nahani Trap should be got approved from the EE
before use) 825.00 257.55 - 2,12,478.75
TOTAL FOR SUB HEAD - 15 - - - 41,15,789.22
SUBHEAD - 16 WATER SUPPLY INSTALLATIONS - -
16.1 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching
,refilling & testing of joints complete as per direction of Engineer in Charge.
- -
External Work - - - -
16.1.1 18.9.3 25 mm nominal outer dia .Pipes. Rmt 1,225.00 209.50 - 2,56,637.50 -
16.1.2 18.9.4 32 mm nominal outer dia .Pipes. Rmt 2,223.00 262.35 - 5,83,204.05 -
16.1.3 18.9.5 40 mm nominal outer dia .Pipes. Rmt 240.00 350.50 - 84,120.00 -
16.1.4 18.9.6 50 mm nominal outer dia .Pipes. Rmt 2,890.00 524.10 - 15,14,649.00 -
16.1.5 18.9.7 62.5 mm nominal outer dia .Pipes. Rmt 60.00 1,462.35 - 87,741.00 -
Internal work: Concealed work - - - -
16.2 18.8 Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fitting,
including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes
&fittingwith one step CPVC solvent cement and cost ofcutting chases and making good
the same including testing ofjoints complete as per direction of Engineer in
Charge.(Concealed/exposed work including cutting chases and making good
the walls etc.) - - - -
16.2.1 18.8.1 15mm nominal outer dia. Pipes. Metre 1,615.00 270.00 - 4,36,050.00 -
16.2.2 18.8.2 20mm nominal outer dia. Pipes. Metre 2,360.00 296.40 - 6,99,504.00 -
16.2.3 18.8.3 25mm nominal outer dia. Pipes. Metre 3,565.00 351.30 - 12,52,384.50 -
16.2.4 18.8.4 32mm nominal outer dia. Pipes. Metre 135.00 422.40 - 57,024.00 -
16.3 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality
(screwed end) : - - - -
16.3.1 18.17.1 25mm dia nominal bore Each 215.00 428.85 - 92,202.75 -
16.3.2 18.17.2 32mm dia nominal bore Each 69.00 501.50 - 34,603.50 -
16.3.3 18.17.3 40mm dia nominal bore Each 19.00 585.50 - 11,124.50 -
16.3.4 18.17.4 50mm dia nominal bore Each 44.00 585.50 - 25,762.00 -

24 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
16.4 18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with
plastic floats complete : - - - -
16.4.1 18.18.3 25 mm nominal bore Each 172.00 449.95 - 77,391.40 -
16.5 18.32 Constructing masonry chamber 30 x 30 x 50 cm, inside with 75 class designation
brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I.
Surface box 100 x 100 x 75mm (inside) with hinged cover fixed in cement concrete
slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10
graded stone aggregate 40mm nominal size) and inside plastering with cement mortar
1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat
cement complete as per standard design.
- - - -
16.5.1 18.32.1 With F.P.S. bricks Each 93.00 1,157.75 - 1,07,670.75 -
16.6 18.33 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.
surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (
inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4
graded stone aggregate 20mm nominal size ) necessary excavation foundation
concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick finished with a floating coat of neat cement complete as per standard design :
- - - -
16.6.1 18.33.1 With F.P.S. bricks Each 135.00 6,754.30 - 9,11,830.50 -
16.7 18.37 Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick
work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with
C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and
RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate
20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine
sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with
cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating
coat of neat cement complete as per standard design.
- - - -
16.7.1 18.37.1 With F.P.S. bricks Each 95.00 6,039.95 - 5,73,795.25 -
16.8 18.46 Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe
and making long screws etc. complete. - - - -
16.8.1 18.46.3 25mm nominal bore Each 345.00 200.10 - 69,034.50 -
16.8.2 18.46.4 32mm nominal bore Each 225.00 240.75 - 54,168.75 -
16.9 NS Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373
and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The
tail pieces if required will be paid separately) : - - - -
16.9.1 50 mm dia nominal bore Each 12.00 10,004.95 - 1,20,059.40
16.10 NS Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts,
rubber insertions etc. complete conforming to IS : 2373 : - - - -
16.10.1 50 mm dia Each 13.00 3,962.36 - 51,510.68
16.11 18.62 Provide and fixing PTMT ball cock of approved quality, colour and make complete
with epoxy coated aluminium rod with L.P/H.P.H.D. plastic ball - - - -
16.11.1 18.62.5 50 mm dia NB, 242mm long. Weighing not less than 1240 gms. Set
25.00 1,402.40 - 35,060.00 -
16.12 19.19 Providing & fixing in position precast RCC manhole cover and frame of reqd.
shape and approved quality. - - - -
16.12.1 19.19.4.1 Circular shape 560 internal dia. Nos 15.00 1,656.70 - 24,850.50 -

25 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
16.13 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank per litre
ISI : 12701 marked with cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but without fittings and the base
support for tank. 1,68,000.00 7.25 - 12,18,000.00 -
16.14 NS Providing and fixing brass automatic air vent at the top of each riser. - - - -
16.14.1 25mm diameter Each 54.00 819.32 - 44,243.28
16.15 NS Providing & Constructing masonry Chamber of size 60x 60x 60 cm in brick work (CD Each
75) in cement mortar 1:4 (1 cement : 4 coarse sand) for Drainage/ Sewage valve,
with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm
deep ( inside) with chained lid and including necessary excavation, foundation
concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as per standard design ,
conforming to CPWD. 131.00 6,947.99 - 9,10,186.69
16.16 NS Providing & Constructing masonry Chamber of size 75 x 75 x 75 cm in brick work (CD Each
75) in cement mortar 1:4 (1 cement : 4 coarse sand) for Drainage/ Sewage valve,
with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm
deep ( inside) with chained lid and including necessary excavation, foundation
concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as per standard
design,conforming to CPWD 17.00 6,042.60 - 1,02,724.20
16.17 NS For pipes Providing & Constructing masonry Chamber of size 75 x 75 x 90 cm in brick Each
work (CD 75) in cement mortar 1:4 (1 cement : 4 coarse sand) for Drainage/ Sewage
valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180
mm deep ( inside) with chained lid and including necessary excavation, foundation
concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as per standard
design,conforming to CPWD.0 to 250 mm diameter
17.00 6,736.01 - 1,14,512.17

26 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
16.18 NS Providing and Fixing of The Ductile Iron covers and frames shall conform to IS-
1865/1991, ISO-1083, Ductile iron grade sg 500/7, Load bearing capacity: a)Light
duty → A-15 → 15 KN, b)Medium duty → B-125 → 125 KN, c)Heavy duty →C-250 →
250 KN d)Extra heavy duty → D-400 → 400 KN, Fractured surface:Bright steely
surface, predominant structure: Ferrite – Pearlite, Density of materials: 7.15 gm/cm3,
Tensile strength (min.):500 N/mm2, Elongation percentage (min.): 7%, Brinell
hardness (HBS): 160 to 240, Linear expansion co-efficient (200c to 400oc): 12.5
mm/m0k, compressive strength: 800 N/mm2, Shear strength: 450 N/mm2, Modulus
of elasticity: 169 GN/m2, Specific heat capacity: 575 J/kgK (200c to 5000c), Thermal
conductivity at 3000c: 35.2 W/(K-m), Poisson's ratio: 0.275, Yield
strength:320N/mm2, Locking arrangements: one end of the cover is hinged with
frame,hence no extra cost is incurred. The sizes of covers specified shall be taken as
the clear internal dimensions of the frame - - - -
16.18.1 Size: 30 X 30, Grade:HD, Weight: 33Kg (Inspection Chamber) Each
25.00 3,451.21 - 86,280.25
16.18.1 Size: 60 X 60, Grade:MD, Weight: 65Kg (OHT) Each
.1 19.00 6,797.42 - 1,29,150.98
16.18.1 Size: 60 X 60, Grade:HD, Weight: 90Kg (Inspection Chamber) Each
.2 121.00 9,412.58 - 11,38,922.18
16.18.1 size: 75 X 75, Grade:HD, Weight: 125Kg (Inspection Chamber) Each
.3 35.00 13,072.81 - 4,57,548.35
TOTAL FOR SUB HEAD - 16 - - 82,06,808.45 31,55,138.18
SUBHEAD - 17 SEWARAGE & DRAINAGE SYSTEM - -
17.1 2.80 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means
in foundation trenches or drains (not exccding 1.5 m in width or 10 sqm on plan)
including dressing of side and ramming of bottoms, lift upto 1.5 m, including getting
out the excavated soil and disposal of surplus excavated soil as directed, within
a lead of 50 m. - -
17.1.1 2.8.1 All kinds of soil. Cum 45.00 157.50 - 7,087.50 -
17.2 2.25 Filling available excavated earth (excluding rock)in trenches, plinth, sides of Cum
foundations etc. in layers not excedding 20cm in depth: consoldating layer by
ramming and watering, lead up to 50 m and lift upto 1.5 m. 27.00 112.40 - 3,034.80 -
17.3 2.26 Extra for every additional lift of 1.5 M.or part thereof in. - - - -
17.3.1 2.26.1 All kinds of soil. Cum 65.00 46.25 - 3,006.25 -
17.4 19.1 Providing laying and jointing glazed stoneware pipes grade „A‟ with stiff mixture of
cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of
joints etc. complete. - - - -
17.4.1 19.1.2 150 mm diameter Rm 555.00 314.35 - 1,74,464.25 -
17.4.2 19.1.4 250 mm diameter Rm 111.00 696.50 - 77,311.50 -
17.4.3 19.1.5 300 mm diameter Rm 96.00 770.40 - 73,958.40 -
17.5 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as
per standard design : - - - -
17.5.1 19.2.2 150 mm diameter S.W. pipe Rmt 2,330.00 724.70 - 16,88,551.00 -
17.5.2 19.2.4 250 mm diameter S.W. pipe Rmt 205.00 977.00 - 2,00,285.00 -
17.6 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I.
grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300
mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not
less than 2.70 kg as per standard design: - - - -

27 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
17.6.1 19.4.2 150 x 100mm size P-type Each 110.00 1,594.35 - 1,75,378.50 -
17.6.1. 19.4.2.1 with FPS bricks class designation 7.5
1 95.00 1,594.35 - 1,51,463.25 -
17.6.2 19.4.3 180x150mm size P type Each 43.00 1,678.85 - 72,190.55 -
17.6.2. 19.4.3.1 with FPS bricks class designation 7.5
1 30.00 1,678.85 - 50,365.50 -
17.7 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars
jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine
sand) including testing of joints etc. complete : - - - -
17.7.1 19.6.2 150 mm dia RCC pipe Rm 2,830.00 348.30 - 9,85,689.00 -
17.7.2 19.6.3 250 mm dia. R.C.C. pipe Rmt 293.00 468.60 - 1,37,299.80 -
17.8 4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work upto plinth level. - - - -
17.8.1 4.1.10 1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40 mm nominal size) cum
19.00 4,004.00 - 76,076.00 -
17.9 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand
) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick
with cement mortar 1:3 (1cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement complete as per standard design :
- - - -
17.9.1 19.7.1Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight of cover and frame to be not less than
38 kg (weight of cover 23kg and weight of frame 15 kg) : - - - -
17.9.1. 19.7.1.2 With Sewer bricks conforming to IS : 4885 Each
1 67.00 8,691.25 - 5,82,313.75 -
17.10 19.7.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty)
560 mm internal diameter, total weight of cover and frame to be not less than 208 kg
(weight of cover 108kg and weight of frame 100 kg) : - - - -
17.10.1 19.7.3.2 With Sewer bricks conforming to IS : 4885 Each 51.00 23,310.25 - 11,88,822.75 -
17.11 19.8 Extra for depth for manholes : - - - -
17.11.1 19.8.1 Size 90x80 cm - - - -
17.11.1 19.8.1.2 With Sewer bricks conforming to IS : 4885 RM
.1 120.00 6,174.65 - 7,40,958.00 -
17.11.2 19.8.2 Size 120x90 cm - - - -
17.11.2 19.8.2.2 With Sewer bricks conforming to IS : 4885 RM
.1 120.00 7,393.00 - 8,87,160.00 -
17.12 19.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class
designation 75 in cement mortar 1:5 (1 cement : 5 fine sand) including 500 x 450 mm
(heavy duty) precast RCC horizontal grating with frame complete as per standard
design: - - - -
17.12.1 19.27.1 with FPS bricks Each
47.00 3,957.50 - 1,86,002.50 -

28 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
17.13 19.21 Making connection of drain or sewer line with existing manhole including breaking into
and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on
both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating
coat of neat cement and making necessary channels for the drain etc. complete :
- - - -
17.13.1 19.21.1 For pipes 100 to 250 mm diameter Each
108.00 364.60 - 39,376.80 -
17.13.2 19.21.2 For pipes 250 to 300 mm diameter Each
88.00 436.20 - 38,385.60 -
17.14 19.9 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and
0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement
plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with
a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse
sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel
in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) finished with a floating coat of neat cement all complete as per
standard design : - - - -
17.14.1 19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation)
560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to
be not less than 182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) including centering shuttering all
complete. (Excavation, foot rests and 12mm thick cement plaster at the external
surface shall be paid for separately) : - - - -
17.14.1 19.9.1.2 With Sewer bricks conforming to IS : 48855 Each
.1 14.00 9,025.15 - 1,26,352.10 -
17.15 19.11 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m
dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 40mm nominal size) and making necessary channel in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) finished with a floating coat of neat cement, all complete as per standard design :
- - - -
17.15.1 19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560
mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be
not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be paid for separately) : - - - -
17.15.1 19.11.1.2 With Sewer bricks conforming IS : 4885 Each
.1 17.00 17,166.25 - 2,91,826.25 -
17.16 19.12 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m
to 2.29 m : - - - -
17.16.1 19.12.2 With Sewer bricks conforming IS : 4885 RM
35.00 6,856.95 - 2,39,993.25 -

29 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
17.17 19.16 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as Each
per IS:10910 on 12mm dia steel bar conforming to IS:1786 having minimum cross
section as 23 mm x 25mm and over all minimum length 263mm and width as 165mm
with minimum 112mm space between protruded legs having 2mm tread on top surface
by ribbing or chequering besides necessary and adequate anchoring projections on tail
length on 138mm as per standard drawing and suitable to with stand the bend test
and chemical resistance test as per specifications and having manufacture's permanent
identification mark to be visible even after fixing, including fixing in manholes with 30
x 20 x 15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20mm nominal size) complete as per design.
285.00 311.60 - 88,806.00 -
17.18 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb
shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m
long complete as per standard design. - - - -
17.18.1 19.32.1 With F.P.S. bricks Each 26.00 18,309.50 - 4,76,047.00 -
TOTAL FOR SUB HEAD - 17 - - 87,62,205.30 -
SUBHEAD - 18 RAIN WATER PIPES AND FITTINGS - -
18.1 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving
10 mm gap for thermal expansion, (i) Single socketed pipes - -
18.1.1 12.41.2 110 mm diameter Rmt 1,550.00 231.65 - 3,59,057.50 -
18.2 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for
unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including
jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal
expansion. - - - -
18.2.1 12.42.1 Coupler - - - -
18.2.1. 12.42.1.2 110 mm Each
1
418.00 138.30 - 57,809.40 -
18.2.2 12.42.3 Single tee with door - - - -
18.2.2. 12.42.3.2 110x110x110 mm Each
1 353.00 306.60 - 1,08,229.80 -
18.2.3 12.42.5 Bend 87.5° - - - -
18.2.3. 12.42.5.2 110 mm bend Each
1 308.00 161.55 - 49,757.40 -
18.2.4 12.42.6 Shoe (Plain) - - - -
18.2.4. 12.42.6.2 110mm Shoe Each
1 210.00 295.10 - 61,971.00 -
18.3 NS Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised -
PVC rain water pipes by means of 50 to 100mm M.S. screws with wall plug of
required length including cutting brick work and fixing in cement mortar 1:4 (1 cement
: 4 coarse sand) and making good the wall etc. complete.
- - - -
18.3.1 50 to 100mm M.S. screws Each 2,085.00 217.93 - 4,54,384.05
18.4 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm Each
diameter and weighing not less than 440 grams. The mouth of rainwater pipe will be
seal with sealent. 430.00 41.10 - 17,673.00 -

30 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
RAIN WATER HARVESTING PIT & PERCOLATION PIT - - - -
18.5 2.26 Every additional lift of 1.5m or part there of in excavation/banking excavated or
stacked materials - - - -
18.5.1 2.26.1 All kind of soils Cum 1,265.00 46.25 - 58,506.25 -
18.5.2 2.26.2 Ordinary or hard rock Cum 840.00 82.95 - 69,678.00 -
18.6 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in Cum
recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete
as per direction of Engineer -in-charge. 342.00 852.60 - 2,91,589.20 -
18.7 4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work upto plinth level. - - - -
18.7.1 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) Cum
32.00 4,301.15 - 1,37,636.80 -
18.8 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in
foundation and plinth in: - - - -
18.8.1 6.2.2 Cement Mortar 1:6 (1 cement : 6 coarse sand). Cum 113.00 4,541.05 - 5,13,138.65 -
18.9 24.9 Providing and fixing factory made precast RCC perforated drain covers,having each
concrete of strength not less than M-25, of size 1000 x 450x50mm, reinforced with 8
mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including
providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge
binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of
Engineer-in-charge. 1,710.00 960.20 - 16,41,942.00 -
18.10 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in cum
recharge pit, in the required thickness, for all leads & lifts, all complete as per direction
of Engineer-in-charge. 1,745.00 504.15 - 8,79,741.75 -
18.11 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the cum
recharge pit, over the existing layer of boulders, in required thickness, for all leads &
lifts, all complete as per direction of Engineer-incharge. 125.00 910.65 - 1,13,831.25 -
18.12 NS Supplying, filling, spreading & leveling Hard broken stone jelly of size range cum
40mm, in rain water Harvesting pit & recharge pit, in the required thickness, for all
leads & lifts, all
complete as per direction of Engineer-in-charge. 815.00 1,309.43 - 10,67,185.45
18.13 NS Supplying, filling, spreading & leveling Hard broken stone jelly of size range cum
20mm, in rain water Harvesting pit & recharge pit, in the required thickness, for all
leads & lifts, all
complete as per direction of Engineer-in-charge. 46.00 1,704.08 - 78,387.68
18.14 NS Supplying, filling, spreading & leveling Hard broken stone jelly of size range 50mm to cum
75mm , in rain water Harvesting pit & recharge pit, in the required thickness, for all
leads & lifts, all
complete as per direction of Engineer-in-charge. 1,611.00 643.88 - 10,37,290.68
18.15 NS Precast Cover Slab:RCC 1:2:4 USING 20mm HBJ STONE cum 18.00 5,055.45 - 90,998.10
18.16 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in
position and binding all complete upto plinth level - - - -
18.16.1 5.22.1 Mild steel and Medium Tensile steel bars Kg 2,600.00 64.95 - 1,68,870.00 -

31 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
18.17 NS Providing and Fixing of The Ductile Iron covers and frames shall conform to IS-
1865/1991, ISO-1083, Ductile iron grade sg 500/7, Load bearing capacity: a)Light
duty → A-15 → 15 KN, b)Medium duty → B-125 → 125 KN, c)Heavy duty →C-250 →
250 KN d)Extra heavy duty → D-400 → 400 KN, Fractured surface:Bright steely
surface, predominant structure: Ferrite – Pearlite, Density of materials: 7.15 gm/cm3,
Tensile strength (min.):500 N/mm2, Elongation percentage (min.): 7%, Brinell
hardness (HBS): 160 to 240, Linear expansion co-efficient (200c to 400oc): 12.5
mm/m0k, compressive strength: 800 N/mm2, Shear strength: 450 N/mm2, Modulus
of elasticity: 169 GN/m2, Specific heat capacity: 575 J/kgK (200c to 5000c), Thermal
conductivity at 3000c: 35.2 W/(K-m), Poisson's ratio: 0.275, Yield
strength:320N/mm2, Locking arrangements: one end of the cover is hinged with
frame,hence no extra cost is incurred. The sizes of covers specified shall be taken as
the clear internal dimensions of the frame - - - -
18.17.1 Size: 60 X 60, Grade:LD, Weight:40Kg (Recharge pit) Each 19.00 4,183.26 - 79,481.94
TOTAL FOR SUB HEAD - 18 - - 45,29,432.00 28,07,727.90
SUBHEAD - 19 PUMPS & ALLIED WORKS - -
19.1 NS Supply, installation, testing and commissioning of (Borewell) Submerssible pump with Set
electric motor, control panel starter etc. complete for lifting water, Discharge
3.5Kl/Hr, Head 167Mtr, Pump rating 2.2KW/3HP 30.00 63,893.02 - 19,16,790.60
19.2 NS Providing & Fixing PVC insulated copper armoured cables includuing necessary
supports clams etc (Make : National/Frandlay) - - - -
19.2.1 3core 1.5mm mtr 125.00 337.79 - 42,223.75
19.2.2 3core 2.5mm mtr 125.00 377.41 - 47,176.25
19.3 NS Supply, installation, testing and commissioning of (Sump to OHT) Submerssible pump Set
with electric motor, control panel starter etc. complete for lifting water, Discharge
18.4Kl/Hr, Head 15Mtr, Pump rating 5.5Kw/7.5Hp 38.00 44,576.52 - 16,93,907.76
TOTAL FOR SUB HEAD - 19 - - - 37,00,098.36
SUB HEAD 20 : SEPTIC TANK - -
EARTH WORK - -
20.1 2.60 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed
earth to be levelled and neatly dressed. - - - -
20.1.1 2.6.1 All kinds of soil cum 1,619.00 155.60 - 2,51,916.40 -
20.2 NS Supplying and filling, in plinth with river sand under floors including, watering, cum
ramming consolidating and dressing complete. 76.00 307.08 - 23,338.08
CONCRETE WORK - - - -
20.3 4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work upto plinth level. - - - -
20.3.1 4.1.5 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) cum
75.00 4,834.30 - 3,62,572.50 -
R.C.C WORKS - - - -
20.4. 5.9 Centring and shuttering including strutting, propping etc. and removal of form for:
- - - -
20.4.1 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 387.00 196.45 - 76,026.15 -
20.4.2 5.9.2 walls (any thickness) including attached pillasters, buttresses, plinth & string courses sqm
etc. 590.00 360.80 - 2,12,872.00 -
20.4.3 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 1,622.00 332.15 - 5,38,747.30 -

32 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
20.4.4 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 145.24 453.35 - 65,843.65 -
20.5 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level. - - - -
20.5.1 5.22.6 Thermo-Mechanically Treated bars Kg 74,840.00 68.10 - 50,96,604.00 -
20.6 5.33 Providing and laying in position machine batched and machine mixed design mix M-25
grade cement concrete for reinforced cement concrete work, using cement content as
per approved design mix, including pumping of concrete to site of laying but excluding
the cost of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,
improve workability without impairing strength and durability as per direction of
Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately). - - - -
20.6.1 5.33.1 All works upto plinth level cum 106.90 6,296.15 - 6,73,058.44 -
20.7 5.37 Providing and laying in position ready mixed M-25 grade concrete for reinforced
cement concrete work, using cement concrete as per approved design mix,
manufactured in fully automatic batching plant and transported to site to work in
transit mixer for all leads, having continious agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concerte work, including pumping of
R.M.C from transit mixer to site of laying, excluding the cost of centering, shuttering
finishing and reinforcement, including cost of admixtures in recommended proportions
as per IS:9103 to accelerate/retard setting of concrete, improve workability without
impairing stregnth and durability as per directions of the Engineer-in-charge. (Note :-
Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as
per design mix is payable/recoverableseparately).
- - - -
20.7.1 5.37.1 All works upto plinth level cum 423.40 6,644.60 - 28,13,323.64 -

33 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
OTHER WORKS - - - -
20.8 NS Providing and Fixing of The Ductile Iron covers and frames shall conform to IS-
1865/1991, ISO-1083, Ductile iron grade sg 500/7, Load bearing capacity: a)Light
duty → A-15 → 15 KN, b)Medium duty → B-125 → 125 KN, c)Heavy duty →C-250 →
250 KN d)Extra heavy duty → D-400 → 400 KN, Fractured surface:Bright steely
surface, predominant structure: Ferrite – Pearlite, Density of materials: 7.15 gm/cm3,
Tensile strength (min.):500 N/mm2, Elongation percentage (min.): 7%, Brinell
hardness (HBS): 160 to 240, Linear expansion co-efficient (200c to 400oc): 12.5
mm/m0k, compressive strength: 800 N/mm2, Shear strength: 450 N/mm2, Modulus
of elasticity: 169 GN/m2, Specific heat capacity: 575 J/kgK (200c to 5000c), Thermal
conductivity at 3000c: 35.2 W/(K-m), Poisson's ratio: 0.275, Yield
strength:320N/mm2, Locking arrangements: one end of the cover is hinged with
frame,hence no extra cost is incurred. The sizes of covers specified shall be taken as
the clear internal dimensions of the frame - - - -
20.8.1 Size: 60 X 60, Grade:MD, Weight: 65Kg (OHT) Each 26.00 6,797.42 - 1,76,732.92
20.9 NS Supply, Installation, Testing & Commissioning of 100mm OD 6KG/Sq.cm Internal & Rmt
External Soil/ Waste Water PVC (SWR) pasted pipe at site using Solvent Cement ISI
Marked [As per IS 4985] along with Heavy duty ISI Marked PVC fittings, Ts, Elbows,
Bends, Ys etc. Adapters, Air vents, Inspection Eyes, Clamping with GI U Clamps as
required for firmly installing the pipes. Testing of the system for leakage and Air
tightness. 21.90 594.35 - 13,016.27
20.10 NS Vent - - - -
20.10.1 Size 100mm (4") Each 37.00 118.87 - 4,398.19
TOTAL For Sub head 7: Septic Tank - - 100,90,964.07 2,17,485.46
TOTAL FOR WATER SUPPLY & SANITARY INSTALLATIONS 352,26,952.72 162,24,089.21
-
Internal & External Fire Fighting system -
1 NS Supplying Installing testing and commissioning electrically driven Terrace pump of Nos
capacity 900 Lpm at 35.0 m Head with all the necessary accessories viz. Auto/Maunal
switch, Star Delta Starter suitable for 10 h.p , remote contolling thru pressure switch
(0-10kg/cm2) Pressure guages, dry running & single phase preventer -minilec make,
operating on 3Ph 50Hz, 400/440V AC supply including foundation, bolts, cables, earth
strip etc. 1.00 1,05,349.18 - 1,05,349.18
2 NS Supplying Installing testing and commissioning approved make Centrifugal pump end Nos
suction type couple to Electric motor of suitable HP, fitted on a common base frame
and rated for Fire duty Including 2nos. Pressure guages fitted on suction & delivery
side of the pump. The pumps shall run on 400/440V, 3ph, 50Hz electric supply
including foundation, bolts, cables, earth strip etc. Duty of pumps : 2850 Lpm @
70.0m Head.Control panel shall be as per specification stated in item No 105. (Cost
of control pannel is not included) 1.00 3,62,869.74 - 3,62,869.74
3 NS Supplying Installing testing and commissioning approved make Centrifugal pump end Nos
suction type couple to Electric motor of suitable HP, fitted on a common base frame
and rated for Fire duty Including 2nos. Pressure guages fitted on suction & delivery
side of the pump. The pumps shall run on 400/440V, 3ph, 50Hz electric supply
including foundation, bolts, cables, earth strip etc. Duty of pumps : 1620 Lpm @
70.0m Head.Control panel shall be as per specification stated in item No 105. (Cost
of control pannel is not included) 1.00 1,68,400.20 - 1,68,400.20

34 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
4 NS Supplying, Installing, testing and commissioning offire hydrant multi stage pump Set
capable of delivering 2850 Lpm @ 70.0m head coupled to water coiled diesel
engine of adequiate HP. It shall be fitted with a radiator on a common base frame
with complete ancilalary units such as calling system, non return value, Y strainers,
fuel tank of 200 lts capacity. Pressure guage, pressure switch, cables, earth strip etc.
Control panel shall be per specification stated in item No.105. (Cost of control pannel
is not included) 1.00 6,43,800.89 - 6,43,800.89
5 NS Supplying, Installing, testing and commisioning electrically driven jockey pump of Nos
capacity 180 Lpm at 75.0m head with all the necessary accessories viz. Pressure
guages etc., operating on 3Ph 50Hz, 400/440 V AC supply including foundation, bolts,
earth strip etc.,Control panel shall be per specification stated in item No.105. (Cost of
control pannel is not included) 1.00 1,11,201.58 - 1,11,201.58
6 NS Supply installing, testing and commissioning of COMMON control panel for firefighting
system consisting of one Diesel engine as common standby & electrical motor driven
60 HP Main fire pump, 35 HP sprinkler pump and Jockey pump of 12.5 HP consisting of
the following:
INCOMING:
1 No. 630 Amps MCCB
1 No. Set of 630 Amps. TPN AL. Bus bars
1 No. 0-630 Amps. Ammeter, 1•No. 0-600V voltmeter with phase selector switch, etc.
complete 1.00 2,32,788.51 - 2,32,788.51
OUTGOING for Main Electric Hydrant Pump: - - - -
Remote starting controlling through pressure switch - - - -
1 No. 320 Amps MCCB - - - -
1 No. star delta starter suitable for 60 HP - - - -
1 No. Single phase preventer suitable for the pump described above - - - -
1 No. set of ON/OFF indicating lamps. - - - -
1 No. Auto/manual selector switch - - - -
OUTGOING for Main Electric Sprinkler Pump: - - - -
Remote starting controlling through pressure switch - - - -
1 No. 200 Amps MCCB - - - -
1 No. star delta starter suitable for 35 HP - - - -
1 No. Single phase preventer suitable for the pump described above - - - -
1 No. set of ON/OFF indicating lamps. - - - -
1 No. Auto/manual selector switch - - - -
OUTGOING for Jockey Pump 12.5HP - - - -
Remote starting controlling through pressure switch - - - -
1 No. 63 amps MCCB - - - -
1 No. star delta starter suitable for 12.50 HP - - - -
1 No. Single phase preventer suitable for the pump described above - - - -
1 No. set of ON/OFF indicating lamps - - - -
1 No. Auto/manual selector switch - - - -
ENGINE CONTROL SECTION N0.1 - - - -
Diesel Engine for Standby pump : - - - -
a) Main switch 2 pole ON/OFF - 1 No. - - - -
b) Battery charger with transformer with rectifier resistance DC ammeter, - - - -
DC voltmeter, T/B selection switch - 1 set - - - -
c) Indicating lamps for fault communication ( Battery charger, supply ON, - - - -
Control ON, engine running, low oil pressure, high water pressure and engine over
speed) - 6 Nos. - - - -
d) Push buttons for starter, stop reset - 4 Nos. - - - -
e) Selector switches (Engine control, mode selector)- 2 Nos. - - - -
f) Auxilary rellays/contractors/timer for sequence operating for starting - - - -
and stopping of the engine - 1 - - - -

35 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
g) Hooter for audio alarm (Industrial type) -1 No. Accessories for outgoing - - - -
i) Remote starting controlling through pressure switch - - - -
supply for the motors : - - - -
Gl SWD earthing wire for the above motor - - - -
Accessories for outgoing supply for Diesel Engine : - - - -
Copper conductors armoured cable 2.5 sqmm of 12 - - - -
Core x 2 runs - - - -
a) Battery 2 strands - - - -
b) Engine ON/OFF 2 strands - - - -
c) Low oil pressure 3 strands - - - -
d) Engine over speed 2 strands - - - -
e) Water temperature 2 strands - - - -
f) Spare 1 strand - - - -
The cost of control panel shall also include necessary pressure switches with necessary
cabling & inter-locked with the panel to enable sequential operation of Pumps,
Including terrace mortar necessary earthling. All the components shall be housed in a
common cubical. - - - -
7 Supplying, fixing and testing CI sluice valves conforming to IS 780 including making
of necessary screwed joint/ flanged joint and also including cost of jointing materials
etc., complete as required as per PN 1.6 tested upto 24kg/cm2 pressure.
- - - -
18.31.1.2 a) 100mm dia Nos 16.00 3,921.30 - 62,740.80 -
18.31.3.2 b)150mm dia Nos 6.00 5,694.00 - 34,164.00 -
18.31.4.2 c) 200mm dia Nos 2.00 11,579.00 - 23,158.00 -
8 18.17.5 Providing and fixing in position GM gate valve with C.l. wheel of approved quality Nos 1,287.50
(screwed end} 65mm nominal bore including cost of all materials, labour and HOM of
equipments with all· leads complete as per specifications. 2.00 - 2,575.00 -
9 18.17.6 Providing and fixing in position GM gate valve with C.l. wheel of approved quality Nos 1,920.60
(screwed end} 80mm nominal bore including cost of all materials, labour and HOM of
equipments with all· leads complete as per specifications. 2.00 - 3,841.20 -
10 18.19.5.1 Providing and fixing in. position 65mm nominal bore gun metal non-return valve Nos 1,769.60
Horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. 2.00 - 3,539.20 -
11 18.19.6.1 Providing and fixing in. position 80mm nominal bore gun metal non-return valve Nos 2,504.30
Horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. 2.00 - 5,008.60 -
12 NS Providing and fixing in. position 100mm nominal bore gun metal non-return valve Nos
Horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. 34.00 3,304.61 - 1,12,356.74
13 NS Supply, installation testing and commissioning of approved make heavy duty (Class
'C') Steel Pipes and fittings confirming to as per is 1239 such as Tees elbows check
nuts Unions, Flanger, Nipples etc., including cutting welding, Trending fixing on walls,
ceiling (Using 41-Tech pipe/M.S. angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.) - - - -
a) 200mm dia Rm 12.00 3,043.09 - 36,517.08
b) 150mm dia Rm 810.00 2,633.98 - 21,33,523.80
c) 100mm dia Rm 208.00 2,223.87 - 4,62,564.96
d) 80mm dia Rm 35.00 1,990.09 - 69,653.15
e) 65mm dia Rm 55.00 1,756.32 - 96,597.60
f) 50 mm dia Rm 40.00 1,521.55 - 60,862.00
g) 40mm dia Rm 80.00 1,404.66 - 1,12,372.80
h)32mm dia Rm 160.00 1,170.88 - 1,87,340.80
i) 25mm dia Rm 240.00 936.11 - 2,24,666.40

36 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
14 NS Wraping and coating of U/G pipe line work includes one coat of anti errossion paint
(Black) and two coats of Bituminous cloth. - - - -
a) 200mm dia Rm 12.00 421.00 - 5,052.00
b) 150mm dia Rm 810.00 292.22 - 2,36,698.20
c) 100mm dia Rm 196.00 233.78 - 45,820.88
d) 80mm dia Rm 5.00 175.33 - 876.65
15 NS Providing and fixing blank flanges as per table 'E" with asbestos gasket, nut, bolts,
washers complete - - - -
c) 100mm dia Nos. 10.00 626.05 - 6,260.50
d)150mm dia Nos. 8.00 978.70 - 7,829.60
e) 200mm dia Nos. 8.00 1,166.91 - 9,335.28
f) 250 mm dia Nos. - - - -
16 NS SITC of 63mm dia single headed Gun metal Hydrant value with black cap and wheet as Nos.
per IS 5290 etc., complete Make: WINCO / NEW Age. 25.00 9,130.26 - 2,28,256.50
17 NS SITC of 63mm dia double headed Gun metal Hydrant value with black cap and wheel Nos.
as per IS 5290 etc., complete. 24.00 16,387.32 - 3,93,295.68
18 NS SITC of Hose cabinet made out of 18 gauge M.S. Sheet with double glass door with Nos.
locking arrangement and painted with two coats of Fire red Enamel paint at outer side
of the box and two coats of white enamel paint at inner side of the box is to
accommodate 2 nos. of Fire hose. box size 20"x24"x 1 0" 45.00 5,033.18 - 2,26,493.10
19 NS Providing and fixing two way fire service inlet to the 100mm dia GI 'C' class pipe wet Nos.
riser to be house in MS bolt with glass cover for front side.etc. complete. 9.00 26,101.04 - 2,34,909.36
- - - -
20 NS Providing and fixing Four way fire service inlet to the 100mm dia GI 'C' class pipe wet Nos.
riser to be house in MS bolt with glass cover for front side.etc. complete.
4.00 33,001.49 - 1,32,005.96
21 NS Providing and fixing dual type pressure switch suitable for 1-10kg/m2 including Nos.
electrical connection setting of cut-in and cut off pressure complete in all respects etc.
complete. 5.00 8,819.22 - 44,096.10
22 NS Providing and fixing dial type pressure gauge with isolation cock and chromeplated
copper pipe etc complete 5.00 3,897.97 - 19,489.85
100mm dia calibration 0-10 kg/sq.cm Nos. - - - -
23 NS Providing and fixing liquid level controller, with necessary fittings etc. complete. 2.00 14,544.82 - 29,089.64
100mm dia calibration 0-10 kg/sq.cm Nos. - - - -
24 NS SITC of Gun metal Branch pipe size of 63mm dia x 19mm dia as per IS 903 Make: Nos.
WINCO/NEWAGE 43.00 3,511.64 - 1,51,000.52
25mm dia - - - -
Fire Extinguishers - - - -
25 NS Providing 6Kg Fire Extinguisher Mono Ammonium Phoshate Powder 50, Stored Nos.
Pressure Type, Pressure Gauge, Gross weight 9.5 Kg, empty weight 3.5 Kg, Can
Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable
discharge mechanism, Range minimum 4 meters, applicable on Class A,B,C and
electrically started Fire, A Rating 21A, B Rating 898, Can construction: Deep drawn &
Co., Mig welded, valve construction : Forging and Machining, Internal Coating of Can ;
Epoxy powder coating, External Coating of Can : Epoxy Polyster power coating, sheet
metal thickness: 1.60MM, Helium Leak Detection Tested, lSI and EN Approved, 5 years
46.00 7,628.53 - 3,50,912.38
warranty.
26 NS Providing 4.5 Kg C02 Gas Type Fire Extinguisher, Trolley Mounted, Easy Weight Nos.
Management used Unused Mechanism, Squeeze Grip, Gross weight 19.1 Kg, empty
Weight 14.6 Kg, Can Height 857MM Diameter 140MM, Discharge Time Less than 10
Sees, Controllable discharge· ( ' mechanism, Applicable on Class B&C Fire, B Rating
218, Can Constrution :Hot spinning/Forging, Value Construction: Forging & Machining,
Internal Coating of Can : Not Apllicable, External Coating of Can : Spray Painting,
Sheet metal thickness : 4.5 MM lSI Approved, 1 Year Warranty.
26.00 12,746.90 - 3,31,419.40

37 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
27 NS Providing 9 Ltr Fire Extinguisher, AFFF Foam Type, Stored Pressure Type, Pressure Nos.
Gouge, Gross Wreight 14.6 Kg, empty Weight 5.6Kg, Can Height 611 MM Diameter
175 MM, Discharge Time Less than 60 Sees, Controllable discharge mechanism, Range
minimum 6 Meters, Applicable on Class A,8&C A Rating 13A, 8 Rating 558, Can
Constrution . Deep drawn & Co, Mig welded, Valve construction; Forging & Machining,
Internal Coating of Can : Epoxy Powder coatingm, External Coating of Can : Epoxy
Polyster Powder coating, sheet metal thickness, 2.0 MM, lSI and EN Approved, Helium
Leak Detection Tested, 1 Year Warranty.
2.00 6,180.29 - 12,360.58
Capacity : 9 Litres - - - -
Fire Buckets and Stand - - - -
28 NS Supplying of four bucket stand along with buckets. Nos. 20.00 1,404.66 - 28,093.20
Fire Hose - - - -
29 NS SITC of RRL Fire hose of 63mm dia 15m length as per IS 84.23 binded with one set of Nos.
male and female lnstantainious Gun metal couping as per IS 903 WINCO/NEW AGE
86.00 9,364.04 - 8,05,307.44
Hose Reel - - - -
30 NS SITC of Hose reel cane M.S. Pressed reel of 600mm dia and swing upto 170 -degree Nos.
with "L" shape carrier 25.00 5,618.62 - 1,40,465.50
31 NS SITC of 19mm dia with wire binded Nylon hose. length of 36.5 mtrs. Nos. 25.00 6,087.17 - 1,52,179.25
32 NS SITC of Manual Call point: It consists of Micro push button switch with LED and Nos.
circutary etc., works on 24V DC LED indicator with glass Fronted, Aiso with hammer foi
breaking the glass incase of Fire. Accomodated in 75x75x30mm size M.S. 16 gauge
red enamel painted box Make/Golbe/ Avel/Royale 19.00 1,404.66 - 26,688.54
33 NS SITC of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia Nos. 9.00 2,458.64 - 22,127.76
34 NS SITC of approved make 15mm dia sprinkler bulb penent/wall mounted type designed Nos
to operate 68 degree centegrade .
Make Tyco/HD FIRE 150.00 585.44 - 87,816.00
35 2.6.1 Excavation in all sorts of soil for laying pipes upto 2OOmm dia including forming cum 155.60
bottom surface to required level, refilling selected excavated earth around the pipe in
layers of 150mm thick, watering consolidating and disposing off the surplus earath
within the sties or as directed by the site engineer etc., complete Depth upto 1.0m.
610.80 - 95,040.48 -
36 18.17.4 Providing and fixing in positionGM gate valve with C.l wheel of approved quality Nos. 750.75
(screwed end) 50mm nominal bore including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. 26.00 - 19,519.50 -
37 NS Y ' Strainer - CI `Y' strainer with bronze perforated sheet basket including rubber
gasket, flanges, nuts, bolts and washers, complete as required. - - - -
b) 200mm dia Nos. 6.00 49,266.96 - 2,95,601.76
c)150mm dia Nos. 9.00 27,072.81 - 2,43,655.29
d) 100mm dia Nos. 2.00 16,732.05 - 33,464.10
38 NS Designing, providing and fixing Orifice plate made out of stainless steel plate
(thickness as per specification) for following size of pipe to reduce pressure upto 3.5
Kg/sqcm complete in all respects. - - - -
a) 65mm dia 8.00 1,691.93 - 13,535.44
b) 80mm dia 12.00 2,383.36 - 28,600.32
c) 100mm dia 20.00 2,924.22 - 58,484.40
39 NS Providing and fixing FLEXIBLE CONNECTORS (Expansion bellows) - On all suction and
delivery lines double flanged reinforced neoprene flexible pipe connectors shall be
provided. Connectors should be suitable for maximum working pressure of each pipe
line on which it is mounted and tested to a test pressure of 1:5 time the operating
pressure. Length of the connector shall be as per manufacturer‟s standard.
- - - -
c)100mm dia Nos. 2.00 13,327.39 - 26,654.78
d)150mm dia Nos. 6.00 20,361.57 - 1,22,169.42

38 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
40 NS Supplying and fixing Air vessel 300mm dia inlet, 25mm drain, 25mm dia connection for Nos.
air release valve including legs, painting with red oxide primer and finished with fire
red enamel paint. It shall be inclusive of all relevent pipes, valves, specials upto pump
header and other accessaries as per local fire brigade standard.
3.00 36,161.47 - 1,08,484.41
41 NS Supplying and fixing Flow switch shall have a paddle made of flexible and sturdy
material of the width to fit within the pipe bore. The terminal box shall be mounted
over the paddle/ pipe through a connecting socket. The Switch shall be potential free
in either N O or N C position as required. The switch shall be able to trip and make /
break contact on the operation of a single sprinkler head. The terminal box shall have
connections for wiring to the Annunciation Panel. The flow switch shall have
connections for wiring the seat shall be of S.S to the Annunciation Panel. The flow
switch shall have IP: 55 protection. The flow switch work at a triggering threshold
bandwidth (flow rate) of 4 to 10 GPM. Further, it shall have a „Retard‟ to compensate
for line leakage or intermittent flows.
2.00 8,279.35 - 16,558.70
100mm dia - - - -
42 NS Providing and fixing Sprinkler installation control valve (Alarm valve) of 100mm dia Nos.
comprising of a mains gate valve, in and out pressure gauge, water motor gong, test
connection of addequate size with valve and other accessories complete.
2.00 77,553.24 - 1,55,106.48
43 NS Supplying and fixing MS Cabinet (size 600 x 450 x 150mm) fabricated from 16 gauge Nos.
M.S.Sheet with full front glass door and locking arrangement for placing spare
sprinklers including fire man axe. 2.00 5,033.18 - 10,066.36
44 NS Providing and fixing Drain Valve 25mm dia, test valve and sight glass as per IS Nos.
Standards. 2.00 8,357.60 - 16,715.20
45 NS Providing & fixing butterfly valve (Body : Grey Cast Iron, Shaft : SS, Disc : SG Iron
(Rilson coated), Liner : HT - EPDM) (upto 150mm dia with hand lever operation &
above with gear box operation). Tested to a pressure not less than 15 Kg/Sq.cm.
Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.
- - - -
80mm nominal dia Nos. 6.00 7,295.69 - 43,774.14
100mm nominal dia Nos. 6.00 9,255.08 - 55,530.48
150mm nominal dia Nos. 6.00 13,884.10 - 83,304.60
Sub Total (A) - - 2,49,586.78 101,60,451.18
Fire Alarm system - - - -
46 NS SITC of 2x1.5 Sq.mm copper armoured cable with fixture etc., . Rm 2,900.00 175.33 - 5,08,457.00
47 NS SITC of electronic Hooter, it consists of electronic circuit to give dual Fire alarm sound Nos.
with works 24V DC with speaker all enclosed in suitable in MS. 16 gauge red painted
box. 21.00 2,106.98 - 44,246.58
48 NS Supply, installation, testing and commissioning of intelligent addressable fire alarm
system extended to the ward with the following items. As per the manufacturer
specification and as per the direction of engineer-in-charge. - - - -
Single Loop Analog adressable fire alarm control panel. 2.00 1,67,805.84 - 3,35,611.68
49 NS SITC OF Smoke/Heat detector Photo electric type detector with base LED indicator on Nos.
smoke detector fixed cum rise temperature type heat detector with base Make
Applow/System Sensor 240.00 4,389.30 - 10,53,432.00
50 NS Providing and fixing Response indicators shall be LED (Light emitting diode) type, and Nos.
shall indicate when the detector senses the fire. 120.00 160.48 - 19,257.60

39 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
51 NS Providing and fixing Duct Mounted Smoke Detectors are designed for early detection of Nos.
smoke and particles of combustion present in the air moving through air conditioning
or ventilation ducts. They are self contained, operating from either 120VAC, 240VAC,
24VAC, 24VDC and provide contacts for both direct fan control and capability for
remote annunciation or alarm panel operation. These units consist of either an
ionization or photoelectric type detector assembly enclosed in a molded NORYL®
plastic housing with a translucent cover. The wiring box, containing two conduit holes,
is an integral part of the housing with access for the detector circuitry by removal of
the cover. All units are UL listed and mount easily to round or rectangular ducts. Units
are reset by momentary interruption of power or by use of a remote reset station.
5.00 8,221.89 - 41,109.45
52 NS Supply, fixing and commissioning Analogue Addressable Fault isolator module Nos. 9.00 4,750.87 - 42,757.83
53 NS Supply, fixing and commissioning Analogue Addressable Monitor module for Nos
monitoring the flowswitch 2.00 5,837.54 - 11,675.08
54 NS Supply, fixing and commissioning Analogue Addressable Control module for AHU & Nos
Lift Tripping 6.00 5,874.20 - 35,245.20
55 NS Fire Alarm Repeater Panel as per standard specification and to match with the detector
manufacturer's specifications for parallel vision of fire risks. 1.00 81,368.00 - 81,368.00
Sub Total (B) - - - 21,73,160.42
Civil Work - - - -
56 18.34.1 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar Nos. 11672.35
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top
diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and
RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating
coat of neat cement complete as per standard design :
13.00 - 1,51,740.55 -
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 - - - -
57 18.35.1 Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement Nos. 16095.10
mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm
top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid
and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement :
5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per standard design :
2.00 - 32,190.20 -
18.35.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
- - - -
Sub Total (C) - - 1,83,930.75 -
Total Estimated Amount Fire Fighting Works (A+B+C) - - 4,33,517.53 123,33,611.60
I Internal Electrical Works
- - - -
A Point Wiring - - - -
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR
PVC insulated copper conductor single core cable in surface / recessed medium class
1.10 PVC conduit, with modular switch, modular plate, suitable GI box and earthing the
point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as
required. - - - -
1 1.10.1 Group A Point 1,832.00 518 - 9,48,976.00 -
2 1.10.3 Group C Point 4,079.00 718 - 29,28,722.00 -

40 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR
PVC insulated copper conductor single core cable in surface / recessed steel conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FR PVC insulated copper conductor single core cable etc as required.
- - - -
3 1.3.3 Group C Point 270.00 1003 - 2,70,810.00 -
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor Point 1069
single core cable in surface / recessed steel conduit, 2 way modular switch, modular
4 1.4
plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper
conductor single core cable etc as required. 16.00 - 17,104.00 -
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper Point 770
conductor single core cable in surface / recessed medium class PVC conduit, 2 way
5 1.11 modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm,
FRLS PVC insulated copper conductor single core cable etc as required.
88.00 - 67,760.00 -
Primary Wiring - - - -
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS
1.7 PVC insulated copper conductor,single core cable in surface/recessed steel conduit as
required. - - - -
6 1.7.2 (i) 2x2.5 Sq mm + 1x2.5 Sq mm earth wire Mts 4,000.00 200 - 8,00,000.00 -
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS
1.14 PVC insulated copper conductor,single core cable in surface/recessed medium class
PVC conduit as required. - - - -
7 1.14.2 (i) 2x2.5 Sq mm + 1x2.5 Sq mm earth wire Mts 32,520.00 131 - 42,60,120.00 -
B Mains Wiring - - - -
wiring for ckt/submain wiring alongwith earth wire with the following sizes of PVC
insulated copper conductor, single core cable in surface/recessed medium class PVC
conduit as reqd. - - - -
8 1.14.10 (i) 4x10 Sq mm + 2x10 Sq mm earth wire Mts. 290.00 597 - 1,73,130.00 -
wiring for ckt/submain wiring alongwith earth wire with the following sizes of PVC
insulated copper conductor, single core cable in surface/recessed Medium calss PVC
conduit as reqd. - - - -
9 1.14.9 (i) 4x6 Sq mm + 2x6 Sq mm earth wire Mts. 255.00 389 - 99,195.00 -
wiring for ckt/submain wiring alongwith earth wire with the following sizes of PVC
insulated copper conductor, single core cable in surface/recessed Medium class PVC
conduit as reqd. - - - -
10 1.14.8 (i) 4x4 Sq mm + 2x4 Sq mm earth wire Mts. 130.00 275 - 35,750.00 -
C Power Wiring - - - -
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS
1.7 PVC insulated copper conductor,single core cable in surface/recessed steel conduit as
required. - - - -
11 1.7.3 (i) 2x4 Sq mm + 1x4 Sq mm earth wire Mts. 4,590.00 231 - 10,60,290.00 -
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS
1.14 PVC insulated copper conductor,single core cable in surface/recessed medium class
PVC conduit as required. - - - -
12 1.14.3 (i) 2x4 Sq mm + 1x4Sq mm earth wire Mts. 25,090.00 162 - 40,64,580.00 -
D Switches and Scokets - - - -
Supply and fixing suitable size GI box with modular plate and cover in front on surface Each 395
or in recess, including providing and fixing 1 no. 6 pin 15/16 & 5/6 amps modular
13 1.32
socket outlet and 15/16 amps modular switch, connection, etc. as required.
849.00 - 3,35,355.00 -
Supply and fixing suitable size GI box with modular plate and cover in front on surface Each 303
or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and
14 1.31
5/6 amps modular switch, connection, etc. as required. (For light plugs to be used in
non residential buildings). 1,034.00 - 3,13,302.00 -

41 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Supplying and fixing following modular switch/ socket on the
1.24 existing modular plate & switch box including connections but
excluding modular plate etc. as required. - - - -
15 1.24.1 5/6 amps switch Each 79.00 81 - 6,399.00 -
16 1.24.4 3 pin 5/6 amp socket outlet Each 182.00 79 - 14,378.00 -
17 1.24.7 TV Socket outlet Each 134.00 94 - 12,596.00 -
Supplying and fixing following size/ modules, GI box along with
1.27 modular base & cover plate for modular switches in recess etc as
required. - - - -
18 1.27.1 1 or 2 Module (75mmX75mm) Each 965.00 166 - 1,60,190.00 -
1.27.3 4 Module (125mmX75mm) Each 30.00 195 - 5,850.00 -
19 1.27.4 6 Module (200mmX75mm) Each 345.00 248 - 85,560.00 -
Supply and fixing of 20A, 240 volts, SPN industrial type socket outlet with 2 pole and Each 954
earth, metal enclosed plug top alongwith 20A "C Curve" SP MCB in sheet steel
20 2.18 enclosure on surface or in recess with chained metal cover for the socket outlet and
complete with connections, testing and commissioning etc., as required.
99.00 - 94,446.00 -
E UPS WIRING - - - -
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS
1.7 PVC insulated copper conductor,single core cable in surface/recessed steel conduit as
required. - - - -
21 1.7.3 (i) 2x4 Sq mm + 1x4 Sq mm earth wire Mts. 960.00 231 - 2,21,760.00 -
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS
1.14 PVC insulated copper conductor,single core cable in surface/recessed medium class
PVC conduit as required. - - - -
22 1.14.3 (i) 2x4 Sq mm + 1x4Sq mm earth wire Mts 5,870.00 162 - 9,50,940.00 -
Switches and Sockets (for UPS) - - - -
Supply and fixing suitable size GI box with modular plate and cover in front on surface Each 395
or in recess, including providing and fixing 1 no. 6 pin 15/16 & 5/6 amps modular
23 1.32
socket outlet and 15/16 amps modular switch, connection, etc. as required.
110.00 - 43,450.00 -
Supply and fixing suitable size GI box with modular plate and cover in front on surface Each 303
or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and
24 1.31
5/6 amps modular switch, connection, etc. as required. (For light plugs to be used in
non residential buildings). 181.00 - 54,843.00 -
Supplying and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE Metre 28
25 1.19 insulated shielded with fine tinned copper braid and protected with PVC sheath in the
existing Surface/Recessed steel/PVC conduit as required 1,738.00 - 48,664.00 -
F JUNCTION BOXES - - - -
Supplying and fixing metal box of following sizes ( Nominal Size) on surface or in
recesss with suitable size of phenolic laminated sheet cover in front including painting
extra as required. As per DSR(E) of CPWD and as per the direction of engineer
incharge. - - - -
26 1.22.5 180 X 100 X 60 Deep Each 150.00 127 - 19,050.00 -
27 1.22.8 200 X 150 X 75 Deep Each 125.00 194 - 24,250.00 -
28 1.22.10 200 X 250 X 75 Deep Each 45.00 261 - 11,745.00 -
29 1.22.15 250 x 300 x 60 Deep Each 55.00 329 - 18,095.00 -
Supplying and fixing of followimg size of PVC conduit along with accessories in recess
including cutting the wall and making good the same in case of recessed conduit as
required - - - -
30 1.21.1 i) 20 mm Mtr. 3,930.00 53 - 2,08,290.00 -
31 1.21.2 ii) 25 mm Mtr. 4,600.00 65 - 2,99,000.00 -
Supplying and fixing of followimg size of Steel conduit along with accessories in recess
including cutting the wall and making good the same in case of recessed conduit as
required - - - -

42 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
32 1.20.1 i) 20 mm Mtr. 1,518.00 121 - 1,83,678.00 -
33 1.20.2 ii) 25 mm Mtr. 1,140.00 142 - 1,61,880.00 -
Sub Total - - 180,00,158.00
I Internal Electrical Works - -
A MCB DBs and MCBs / RCCBs - -
Supplying and fixing following way prewired TP&N MCB distribution board of steel
sheet for 415volts on surface / recess complete with loose wirebox, terminal
connectors for all incoming and outgoing circuits, duly prewired with suitable size FR
2.8 PVC insulated copper conductor upto terminal blocks, tinned copper bus bar, neutral
link, earth bar, din bar, detachablegland plate, interconnections, power painted
including earthing etc., as required. (But without MCB / RCCB / Isolator)
- - - -
1 2.8.8 12 way (4+36), Double door Each 37.00 12782 - 4,72,934.00 -
2 2.8.7 8 way (4+24), Double door Each 41.00 10405 - 4,26,605.00 -
3 2.8.5 4 way (4+12), Double door Each 26.00 7357 - 1,91,282.00 -
Supplying and fixing following way prewired SP&N MCB distribution board of steel
sheet for 240 volts on surface/ recess complete with loose wire box, terminal
connectors for all
2.7 incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated
copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar,
din bar, detachable gland plate, interconnections, powder painted including earthing
etc. as required. (But without MCB/ RCCB/ Isolator) - - - -
4 2.7.5 2 + 8 way, Double door Each 5.00 2995 - 14,975.00 -
5 2.7.6 2 + 12 way, Double door Each 6.00 3613 - 21,678.00 -
supllying and fixing following way prewired vertical type TP&N MCB distribution board
of steel sheet for 415 volts on surface/recess complete with loose wire bo of sheet
steel dust protected ,duly powder painted,inclusive of 200amps tinned copper bus
bar,common neutral link,earth bar for mounting MCB's terminal connectors for all
2.9 incoming and outgoing circuits,duly prewired with adequate size of FRLS PVC insulated
copper conductor upto the terminal connector/neutral link,earthing etc as
required(But without MCB/RCCB/isolator).(Note:prewired vertical type MCB TPDB is
normally used where 3 phase outlets are required)
- - - -
6 2.9.7 8 way double door Each 3.00 11123 - 33,369.00 -
providing and fixing following rating and breaking capacity and pole MCCB in existing
2.2 cubicle panel board including driling holes in cubicle panel, making connections,etc.as
required - - - -
7 2.2.1 100amps, 16KA Each 3.00 3205 - 9,615.00 -
Supply and fixing of 63 amps rating, four pole,415 volts, MCB in the existing MCB DB
complete with connections, testing and commisioning etc. as required. - - - -
8 MR 63 amps four pole MCB - 10 kA Each 107.00 2,118.87 - 2,26,719.09
Supply and fixing of 32 amps rating, four pole,415 volts, MCB in the existing MCB DB
complete with connections, testing and commisioning etc. as required. - - - -
9 MR 32 amps four pole MCB - 10 kA Each 67.00 1,434.37 - 96,102.79
Supply and fixing of 63 amps rating, double pole, 415 volts, RCBO in the existing MCB
DB complete with connections, testing and commisioning etc. as required.
- - - -
10 MR 63 amps double pole RCBO - 30 mA Each 141.00 5,890.04 - 8,30,495.64
Supply and fixing of 32 amps rating, double pole, 415 volts, RCBO in the existing MCB
DB complete with connections, testing and commisioning etc. as required.
- - - -
11 MR 32 amps double pole RCBO - 30 mA Each 226.00 4,977.71 - 11,24,962.46

43 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Supply and fixing 5 amps to 32 amps rating , 240/415 volts, 'C' curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc., as required.
- - - -
12 2.10.1 Single pole Each 2,785.00 169 - 4,70,665.00 -
13 2.10.3 Double pole Each 245.00 459 - 1,12,455.00 -
14 2.10.5 Triple pole and neutral Each 33.00 887 - 29,271.00 -
Supply and fixing of TP sheet steel enclosure on surface/recess along with Each 868
15 2.17 16/25/32amps 415 volts "C'" curve TP MCB complete with connections,testing and
commissioning etc., as required 90.00 - 78,120.00 -
Supply and fixing of 125 amps rating, TPN,415 volts, MCCB with enclosure and
16 MR
connections, testing and commisioning etc. as required. - - - -
125 amps TPN MCCB with enclosure - 25 KA Each 10.00 13,612.68 - 1,36,126.80
FLOOR - RACEWAYS (UPS & RAW POWERS) - - - -
Supplying, erecting,PVC Races ways with cover made out of 1.6 mm thick of various
sizes with necessary screws,etc., The cost including the chipping the floor etc.,
- - - -
17 MR 150mm (w) x 25mm (D)- 2 compartment metre 85.00 733.04 - 62,308.40
18 MR 75mm (w) x 25mm (D)- 2 compartment metre 68.00 733.04 - 49,846.72
19 MR 50mm (w) x 38mm (D)- 1 compartment metre 52.00 704.31 - 36,624.12
20 MR 100mm (w) x 38mm (D) -2 compartment metre 54.00 1,301.63 - 70,288.02
Supplying, erecting,of Junction boxes for race ways Sizes as follows - - - -
21 MR 150x150 with S.S cover plate Each 44.00 216.94 - 9,545.36
22 MR 225x225 with S.S cover plate Each 31.00 294.21 - 9,120.51
- - - -
B LT Panels - - - -
23 MR Lighting panel-1 Each 10.00 3,15,293.71 - 31,52,937.10
A) Incomer : 1No - - - -
250AMPS, TPN, MCCB with Thermal O/L and Magnetic S/C Protection, Earth fault and
Neutral current protection. - - - -
B) Indication & Metering: - - - -
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF / TRIP indications. 1 Sets of 3 phase, 4 wire,250/5A, Digital flush
type Class-I accuracy multifunction meter with RS485 modbus connectivity. 1 Nos.
250/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
250 A, TPN Aluminium Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings : 9 nos - - - -
125 Amps TPN MCCBwith Thermal O/L and Magnetic S/C Protection - 3 NOS. - - - -
63 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection - 6NOS. - - - -
24 MR Sub Lighting panel Each 3.00 1,46,719.17 - 4,40,157.51
A) Incomer : 1No - - - -
125AMPS, TPN, MCCB with Thermal O/L and Magnetic S/C Protection, Earth fault and
Neutral current protection. - - - -
B) Indication & Metering: - - - -
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF / TRIP indications. 1 Sets of 3 phase, 4 wire, 125/5A, Digital flush
type Class-I accuracy multifunction meter with RS485 modbus connectivity. 1 Nos.
125/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
200 A, TPN Aluminium Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings : 5nos - - - -
63 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection - 5NOS. - - - -

44 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
25 MR Power Panel-1 Each 2.00 3,64,091.13 - 7,28,182.26
A) Incomer : 1No - - - -
400 AMPS, TPN, MCCB with Thermal O/L and Magnetic S/C Protection, Earth fault and
Neutral current protection. - - - -
B) Indication & Metering: - - - -
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF /TRIP indications. 1 Sets of 3 phase, 4 wire, 400/5A, Digital flush
type Class-I accuracy multifunction meter with RS485 modbus connectivity. 1 Nos.
400/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
400 A, TPN Aluminium Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings : 7 Nos. - - - -
200 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection -
3NOS. - - - -
63 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection -
6NOS. - - - -
26 MR Sub Power Panel Each 5.00 3,06,042.60 - 15,30,213.00
A) Incomer : 1No - - - -
200 AMPS, TPN, MCCB with Thermal O/L and Magnetic S/C Protection, Earth fault and
Neutral current protection. - - - -
B) Indication & Metering: - - - -
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF /TRIP indications. 1 Sets of 3 phase, 4 wire, 200/5A, Digital flush
type Class-I accuracy multifunction meter with RS485 modbus connectivity. 1 Nos.
200/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
200 A, TPN Aluminium Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings : 8 Nos. - - - -
100 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection -
2NOS. - - - -
63 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection -
6NOS. - - - -
27 MR EMERGENCY LIGHTING PANEL Each 8.00 1,80,669.64 - 14,45,357.12
A) Incomer : 1No - - - -
63AMPS, 4P, MCCB with Thermal O/L and Magnetic S/C Protection, Earth fault and
Neutral current protection. - - - -
B) Indication & Metering: - - - -
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF / TRIP indications. 1 Sets of 3 phase, 4 wire, 250/5A, Digital flush
type Class-I accuracy multifunction meter 1with RS485 modbus connectivity. 1 Nos.
250/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
200A, TPN Aluminum Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings :5 Nos. - - - -
32 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection -5NOS.
- - - -
28 MR LIFT PANEL/Lighting Panel Each 3.00 2,24,840.02 - 6,74,520.06
A) Incomer : 1No - - - -
250AMPS, TPN, MCCB of 36 kA Short Circuit Rating with Thermal O/L and Magnetic
S/C Protection, Earth fault and Neutral current protection. - - - -
B) Indication & Metering: - - - -

45 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF / TRIP indications. 1 Sets of 3 phase, 4 wire, 250/5A, Digital flush
type Class-I accuracy multifunction meter 1with RS485 modbus connectivity. 1 Nos.
250/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
250A, TPN Aluminum Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings :6 Nos. - - - -
63 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection - 6 NOS. - - - -
- - - -
23 MR Lighting & Power panel Each 2.00 2,45,952.45 - 4,91,904.90
A) Incomer : 1No - - - -
250AMPS, TPN, MCCB with Thermal O/L and Magnetic S/C Protection, Earth fault and
Neutral current protection. - - - -
B) Indication & Metering: - - - -
1 Sets of R,Y,B phase indicating lights (LED-TYPE) controlled with control MCB's and
breaker ON / OFF / TRIP indications. 1 Sets of 3 phase, 4 wire,250/5A, Digital flush
type Class-I accuracy multifunction meter with RS485 modbus connectivity. 1 Nos.
250/5A, Class-I, 5VA burden moulded CT's. - - - -
C) Busbar: - - - -
250 A, TPN Aluminium Busbar Chamber for the entire length of the Panel as per
specification - - - -
D) Outgoings : 9 nos - - - -
63 Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection - 9NOS. - - - -
- - - -
Cable tray - - - -
Supplying and installing following size of perforated pre-painted M.S. cable trays with
perforation not more than 17.5%, in convenient sections, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required. - - - -
29 4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness Mtr. 1,389.00 520 - 7,22,280.00 -
30 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness Mtr. 500.00 789 - 3,94,500.00 -
31 4.1.7 600 mm width X 50 mm depth X 2.0 mm thickness Mtr. 154.00 1386 - 2,13,444.00 -
Supply, installation, testing and commissioning of DOL starter with accessories etc., Nos.
32 MR
29.00 7,429.42 - 2,15,453.18
Sub Total - - 31,91,193.00 113,30,865.04
A Light Fitting / Fans - -
Note: Catalogue numbers indicated are only to describe type of light fixture required.
Lamp Colour shall be - 84 or as approved by
Architect / Consultant. - -
Whether explicitly mentioned or not vendor shall consider light fixtures with necessary
powerfactor improvement condensors. Unless specified all light fixtures shall be
considered with electromagnetic ballasts. The loss of ballasts shall not exceed 5.5
Watts
Vendor shall consider necessary fixing hardware and components to install light
fixtures. The hardware viz., anchor fasteners, suspending GI chains, down rods will
not be measured seperately. Vendor shall assume a minimum suspension length of 0.5
Mtrs - - - -
Light Fixtures. Quoted rate shall include mounting bracket and lamps (Note: The rates
are inclusive of all leads, lifts of all materials and labour charges as per the detailed
technical specifications and standard specifications, drawings, etc., complete and as
per directions of Architects/Engineer-in-Charge.) - - - -

46 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR

Supply and fixing of LED Tube light fitting, 1x19w 4', 230v, attractive wall mounted Each
type with mettalic channel and white reflector, suitable for mirror fittings with ballasts,
1 MR lamp holders, connector block, etc. complete with all accessories internally pre wired
and including connecting up with twin core twisted flexible copper conductor cable with
suitable size. Philips Catalogue No.: Endura LED BN 108 LED 20S or equivalent. 985.00 1,931.65 - 19,02,675.25
supply and fixing of 1 x 14w LED tube light - 2' lengh, 230v, , epoxy powder coated Each
CRCA sheet housing with reflector cover channel, with electronic driver, bipin holders,
2 MR connector block, etc., complete with all accessories internally pre wired and including
connection up with twin core twisted flexible copper conductor cable with suitable size.
Philips Catalogue No. LL20-111-XXX-XX, 2'LED batten 14W or equivalent 113.00 1,485.88 - 1,67,904.44
Supply and fixing of LED decorative light fitting, 1x19w, 230v, attractive wall Each
mounted round type with mettalic channel and white reflector, suitable for mirror
3 MR fittings with ballasts, lamp holders, connector block, etc. complete with all accessories
internally pre wired and including connecting up with twin core twisted flexible copper
conductor cable with suitable size. Philips Catalogue No.: My living 36349 19W or
equivalent 612.00 2,476.47 - 15,15,599.64
Supply and fixing of LED decorative light fitting, 1x40w, 230v, attractive 2' x 2' Each
recess mounted square type with mettalic channel and white reflector, suitable for
4 MR mirror fittings with ballasts, lamp holders, connector block, etc. complete with all
accessories internally pre wired and including connecting up with twin core twisted
flexible copper conductor cable with suitable size. Philips Catalogue No.: Full glow
standard MIDFLUX LED 819.00 3,764.24 - 30,82,912.56
Supply and fixing of LED Step light fitting, complete with all accessories internally pre Each
5 MR wired and including connecting up with twin core twisted flexible copper conductor
cable with suitable size. Philips make 67.00 3,764.24 - 2,52,204.08
Supply and fixing of LED 1x25W wall mounted light fitting, complete with all Each
accessories internally pre wired and including connecting up with twin core twisted
6 MR
flexible copper conductor cable with suitable size. Philips catalogur no.: SM 518C LED
9S 6500 PSC OD WH 25W or equivalent. 251.00 3,764.24 - 9,44,824.24
Each
Supply and fixing of 10 w, bulk head LED luminaries, with control gears, heat sink and
lenses, etc., complete with all accessories internally pre wired and including
7 MR
connecting up with twin core twisted flexible copper conductor cable with suitable size
of 230v,50Hz. Philips Catalogue No.: WT202WLED6S CWPSUSIPC or equivalent 108.00 941.06 - 1,01,634.48
Supplying and fixing of 1 x 18 watts recessed mounted with CFL - Lamp Fitting Philips Each
8 MR
catalogue No. FBS 075/118 or equivalent . 78.00 822.19 - 64,130.82
Supplying and fixing of 2 x 18 watts recessed mounted with PL - Lamp Fitting Philips Each
9 MR
catalogue No. FBH 225 / 218 or equivalent 164.00 1,899.95 - 3,11,591.80
Supply and fixing of 300mm dia wall mounted fan as per standard specification and as Each
10 MR
directed by Engineer - in - charge. 328.00 1,609.71 - 5,27,984.88
11 MR Supply and fixing of 250mm dia exhaust fan with automatic louvers shutters. Each 191.00 1,111.44 - 2,12,285.04
Supplying, installation, testing and commissioning of following size special design Each
energy saving ceiling fans along with fan hook similar to Havell's ES-50/cromptons or
12 MR equivalent with low power consumption as specified below aluminium motor covers of
larger diameters complete with double ball bearings, aluminium blades, down rod,
shackle insulator, canopy but without regulator etc complete as required - 1200mm
sweep ceiling fan 930.00 1,882.12 - 17,50,371.60
- - - -
Supply and fixing of Stepped type electronic type fan regulator on the existing Each 284
13 1.25 modular plate switch box including connection but excluding plate tc. As required
921.00 - 2,61,564.00 -
Supply and fixing 3 pin 5 amps ceiling rose on the existing junction box/wooden block Each 43
14 1.33
including connection etc., as required 2,040.00 - 87,720.00 -
47 Signature of Contractor with Seal/ Stamp
BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
15 1.34 Supply and Fixing of Batten/Angle Holder including Connection etc as required Each 456.00 74 - 33,744.00 -
16 MR Supplying and fixing 12 watts CFL Lamp suitable to Batten/Angle holder. Each 456.00 104.01 - 47,428.56
B UPS - - - -
Supplying and fixing of 15 KVA, 415 volts, 50Hz on line UPS (30 minutes backup). UPS Each
17 MR
suitable for light, and other electrical equipment. 7.00 4,81,689.95 - 33,71,829.65
Supplying and fixing of 1 x 7 watts CFL Wall mounted emergency light philips or Each
18 MR
equivalent (above the rate including batery, backup for 4Hrs) 49.00 1,646.36 - 80,671.64
sub Total - - 3,83,028.00 143,34,048.68
A Earthing - -
Supply and laying of following types of earthing conductor and inter connecting the
equipments, DBs, Switch boards including earth pit. - -
25mm x 5 mm GI strip along cable trays, & looping with DBs / SBs. Including forming Mts. 142
1 5.15 earth grid. As per DSR(E) of CPWD and as per the direction of engineer incharge.
3,207.00 - 4,55,394.00 -
Supplying and laying of 4.00mm dia copper wire on surface or in recess for loop Mts. 86
2 5.19 earthing along with existing surface/recessed conduit/submain wiring/cable as
required. 1,768.00 - 1,52,048.00 -
Providing and fixing 6 SWG dia GI Wire on surface or in recessed for loop earthing Mts. 23
3 5.18 along with existing surface/recessed conduit/sub main wiring/cable as required
1,920.00 - 44,160.00 -
Providing and fixing earth bus of 50mmx5mm copper strip on surface for connection Mts. 1599
4 5.20
etc.as required 44.00 - 70,356.00 -
Sub Total - - 7,21,958.00
A MV Cables and Terminations - -
Supply the following size of approved make, 650 / 1100 V grade XLPE insulated with
PVC inner sheath steel armouring and with an outer protective sheath of flame
MR retardant low smoke (FRLS ZH PVC) compound, conforming to IS: 7098 (PartI) cables
shall have high conductivity stranded aluminium or copper conductors and cores colour
coded to the Indian standards. - - - -
1 3.5 Core 240 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Al.cable Mtr. 110.00 673.60 - 74,096.00
2 3.5 Core 185 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Al.cable Mtr. 150.00 533.93 - 80,089.50
3 3.5 Core 150 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Al.cable Mtr. 119.00 424.96 - 50,570.24
4 3.5 Core 120 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Al.cable Mtr. 565.00 363.55 - 2,05,405.75
5 3.5 Core 95 Sq.mm XLPE, FRLS ZH A2XFY, 1.1 KV grade Al. cable Mtr. 1,006.00 292.22 - 2,93,973.32
6 3.5 Core 70 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Aluminium cable Mtr. 932.00 224.86 - 2,09,569.52
7 3.5 Core 50 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Aluminium cable Mtr. 311.00 173.35 - 53,911.85
8 3.5 Core 25 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Aluminium cable Mtr. 1,080.00 110.95 - 1,19,826.00
9 4 Core 25 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Aluminium cable Mtr. 292.00 160.48 - 46,860.16
10 4 Core 16 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Aluminium cable Mtr. 1,488.00 120.85 - 1,79,824.80
11 4 Core 10 Sq.mm XLPE FRLS ZH YWY , 1.1 KV grade CU. Cable Mtr. 1,376.00 140.66 - 1,93,548.16
12 4 Core 6 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Aluminium cable Mtr. 535.00 62.41 - 33,389.35
13 1 Core 25 Sq.mm XLPE FRLS ZH 1.1 KV grade CU.Flexible cable Mtr. 270.00 136.70 - 36,909.00
14 1 Core 90 Sq.mm XLPE FRLS ZH, 1.1 KV grade CU.Flexible cable Mtr. 160.00 636.95 - 1,01,912.00
MV Cable Laying - - - -
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV
7.1 grade of following size direct in ground including excavation,sand cushioning,protective
covering and refilling the trench etc as required. - - - -
15 7.1.1 Upto 35 sq.mm Mtr. 470.00 195 - 91,650.00 -
16 7.1.2 Above 35sq.mm and upto 95sq.mm Mtr. 350.00 202 - 70,700.00 -
17 7.1.3 Above 95sq.mm and upto 185sq.mm Mtr. 90.00 210 - 18,900.00 -
18 7.1.4 Above 185sq.mm and upto 400sq.mm Mtr. 30.00 233 - 6,990.00 -
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV
grade of following size direct in ground in the same trench in one tier horizontal
7.2
formation including excavation,sand cushioning,protective covering and refilling the
trench etc as required. - - - -

48 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
19 7.2.1 Upto 35 sq.mm Mtr. 470.00 133 - 62,510.00 -
20 7.2.2 Above 35sq.mm and upto 95sq.mm Mtr. 350.00 141 - 49,350.00 -
21 7.2.3 Above 95sq.mm and upto 185sq.mm Mtr. 90.00 149 - 13,410.00 -
22 7.2.4 Above 185sq.mm and upto 400sq.mm Mtr. 30.00 171 - 5,130.00 -
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV
7.5 grade of following size in the existing RCC/HUME/METAL pipe as required. - - - -
23 7.5.1 Upto 35 sq.mm Mtr. 290.00 16 - 4,640.00 -
24 7.5.2 Above 35sq.mm and upto 95sq.mm Mtr. 240.00 25 - 6,000.00 -
25 7.5.3 Above 95sq.mm and upto 185sq.mm Mtr. 80.00 33 - 2,640.00 -
26 7.5.4 Above 185sq.mm and upto 400sq.mm Mtr. 30.00 58 - 1,740.00 -
Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable
7.8
of 1.1KV grade of following size on cable tray as required - - - -
27 7.8.1 Upto 35 sq.mm Mtr. 3,776.00 20 - 75,520.00 -
28 7.8.2 Above 35sq.mm and upto 95sq.mm Mtr. 1,446.00 48 - 69,408.00 -
29 7.8.3 Above 95sq.mm and upto 185sq.mm Mtr. 834.00 59 - 49,206.00 -
30 7.8.4 Above 185sq.mm and upto 400sq.mm Mtr. 110.00 91 - 10,010.00 -
End termination and connection of XLPE (FRLS) aluminium / copper conductor
armoured UG cable including supply of single compression, type tinned brass cable
glands, suitable size tinned copper criumping type lugs, including gland earthing as
required. - - - -
31 9.1.29 3.5 Core 240 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Al.cable Each 12.00 969 - 11,628.00 -
32 9.1.27 3.5 Core 185 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Al.cable Each 8.00 784 - 6,272.00 -
33 9.1.26 3.5 Core 150 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade l.cable Each 2.00 576 - 1,152.00 -
34 9.1.25 3.5 Core 120 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Al.cable Each 10.00 484 - 4,840.00 -
35 9.1.24 3.5 Core 95 Sq.mm XLPE, FRLS A2XFY, 1.1 KV grade Al. cable Each 42.00 466 - 19,572.00 -
36 9.1.23 3.5 Core 70 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Aluminium cable Each 42.00 382 - 16,044.00 -
37 9.1.22 3.5 Core 50 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Aluminium cable Each 16.00 342 - 5,472.00 -
38 9.1.20 3.5 Core 25 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Aluminium cable Each 40.00 247 - 9,880.00 -
39 9.1.34 4 Core 25 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Aluminium cable Each 70.00 248 - 17,360.00 -
40 MR 4 Core 6 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Aluminium cable Each 18.00 1,471.03 - 26,478.54
41 9.1.33 4 Core 16 Sq.mm XLPE FRLS A2XFY, 1.1 KV grade Aluminium cable Each 126.00 245 - 30,870.00 -
42 9.1.32 4 Core 10 Sq.mm XLPE FRLS , 1.1 KV grade CU. cable Each 148.00 193 - 28,564.00 -
43 MR 1 Core 25 Sq.mm XLPE FRLS , 1.1 KV grade CU.Flexible cable Each 120.00 1,471.03 - 1,76,523.60
44 MR 1 Core 90 Sq.mm XLPE FRLS , 1.1 KV grade CU.Flexible cable Each 20.00 1,541.36 - 30,827.20
Sub Total - - 6,89,458.00 19,13,714.99
A Data & Telephone Wiring - -
Supplying and fixing following modular Switch/socket on the existing modular plate &
1.24 switch box including connections but excluding modular plate etc. as required.
- - - -
1 1.24.6 Telephone Socket Outlet Each 232.00 95 - 22,040.00 -
Supplying and laying of UTP 4 pair CAT6 LAN Cable in the existing surface/recessed per m
2 MR
steel/PVC conduit as required 5,765.00 33.68 - 1,94,165.20
Supply and wiring with 2 pair 0.5 sq.mm telephone cable. As per the manufacturer
1.18
specification and as per the direction of engineer incharge. - - - -
3 1.18.2 2 Pair Mts. 4,875.00 18 - 87,750.00 -
- - - -
Supply and wiring with 10 pair telephone cable in the existing conduit. As per the
4 MR manufacturer specification and as per the direction of engineer incharge. e. (1.18x10)
- - - -
10 Pair Mts. 1,425.00 34.67 - 49,404.75
Supply and providing RJ 45 data terminal unit with metal box & cover plate etc., as Nos
5 MR required . As per the manufacturer specification and as per the direction of engineer
incharge. 168.00 247.65 - 41,605.20

49 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
MR Providing and fixing in position 2mm thick M.S. Telephone junction box of size suitable
6 for fixing of following Krone Tag Block with key lock arrangement. Also provide Tag
blocks & clamps for fixing tag blocks. - - - -
a) 20 pair Telephone Tag Block Box Each 3.00 941.06 - 2,823.18
Supply & Erection of Component - - - -
7 MR CAT-6 Patch Cord 3FT Nos. 52.00 198.12 - 10,302.24
8 MR 15 U Rack with Door and Side Panels Nos. 1.00 11,887.07 - 11,887.07
9 MR CAT-6 24-Port Patch Panel CISCO Make Nos. 1.00 5,943.54 - 5,943.54
10 MR 10/100MBPS 24- Port Managed Switch CISCO Make Nos. 1.00 44,576.52 - 44,576.52
MR Projection System with DLP Technology, with native resolution of 1024 x 768 pixels,
XGA 3000 ANSI lumens, contrast ratio 2200:1, Fully featured IR remote with
11
accessories, complete as per specification and as required.complete with 120" diagonal
size folding screen and all accessories complete as required. - - - -
Each 7.00 89,153.05 - 6,24,071.35
Sub Total - - 1,09,790.00 9,84,779.05
Internal Electrical Works - - 230,95,585.00 285,63,407.76
External Electrical works, Street lighting including electrical substation - -
H T Breaker PL - -
Supplying, installing, testing and commissioning of Outdoor Type Floor Mounted metal Each
clad, 11 KV VCB, 26 KA Panel with 2 Nos 630 Amps LBS as Incomng and 1 No 630
Amps HT VCB as Outgoing, totally enclosed, fully interlocked, horizondal drw out,
horizondal isolation type breaker as per IS 13118, having capacity mentioned below,
1 MR single break, trip free mechanisam,motorised charged, motorised closing breaker
suitable for use on 11 KV, 3 Phase, 50 Hz AC Supply,AIr insulated Copper Bus bars of
630 Amps capacity, breaker featured with mechanical ON / OFF indicator with hand
trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4 NC and
equipped with the following swicthgear and accessories.
1.00 12,25,926.70 - 12,25,926.70
Incoming .. 630 Amps TP LBS .. 2 Nos - - - -
Outgoing .. 630 Amps TP VCB .. 1 No - - - -
Supply and Installation, Testing & Commissioning of 11 KV, 26KA, 630Amps VCB - 3 Each
Panel, totally enclosed, indoor / outdoor, fully interlocked, horizondal drw out,
horizondal isolation type breaker as per IS 13118, having capacity mentioned below,
single break, trip free mechanisam,motorised charged, motorised closing breaker
2 MR suitable for use on 11KV bars of 630 Amps capacity, breaker featured with mechanical
ON / OFF indicator with hand trip device, spring release coil, shunt trip coil and
auxiliary switch of 4 NO + 4 NC and equipped with the following swicthgear and
accessories. (as per CEIG regulation)
1.00 25,45,976.23 - 25,45,976.23
250 KVA Transformer - - - -
Supply, Unloading, Erection, Testing and commissioning of OUTDOOR type 11 KV/433 Nos.
V., 250 KVA (DYN11) Power Transformer with Winding Temperature alarm and trip, Oil
3 MR
Temperature alarm and Trip, buchholz Alarm and trip with standard fittings with On
load tap changer (On OLTC) as per IS code. 2.00 7,96,519.07 - 15,93,038.14
- - - -
200KVA DG set with AMF Panel - - - -
Supply erection testing and commissioning of 200KVA DG set with AMF panel shall be Nos.
earth fault protection as per CEIG regulation and IS specification.supply and erection
4 MR of 400A 4P, MCCB -1 no.1set of Digital electronic meter to indicate V,A,F,and three
Phase Indication lamps,The busbar rating shall be of 400A rating aluminium bus
bar.(refer Technical specification) Necessary battery for 200 KVA DG set and exhaust
shall be included . (As per IS standard) 1.00 17,83,060.92 - 17,83,060.92
LT PANELS - - - -
MV Panel-1 - - - -

50 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Supply and erection of the board consisting of : Digital electronicmeter to indicate Nos.
V,A,F and Load Managers with three phase Indication lamp, earth falt Relay etc.The EB
5 MR busbar rating shall be of 400A rating aluminium bus bar (including arranging for rule-
63 inspection and obtaining safety certificate from CEIG)
1.00 6,82,516.10 - 6,82,516.10
1.EB INCOMMER 1 & 2 - - - -
a) 400A, 4P, Motorised MCCB equipped with integral Current Transformers and self
powered Protection Relay having variable settings for Overcurrent, Short Circuit and
Earth Fault with necessary time delay settings and measurement & indication of
various parameters, interfaced through LCD display (continuously ON) window and
suitable BMS connectivity. The breaker section should be equipped with 1 Set of ON &
OFF Push Buttons, 1 Set of auxilliary contacts and 1 Set of LED based indication lamps
for ON, OFF & TRIP indications.-2Nos - - - -
2.DG INCOMMER 1 - - - -
a) 400 A, 4P, Motorised MCCB equipped with integral Current Transformers and
Protection Relay having variable settings for Overcurrent, Short Circuit and Earth Fault
with necessary time delay settings and measurement & indication of various
parameters, interfaced through LCD display (continuously ON) window and suitable
BMS connectivity. The breaker section should be equipped with 1 Set of ON & OFF
Push Buttons, 1 Set of auxilliary contacts and 1 Set of LED based indication lamps for
ON, OFF & TRIP indications.and suitable extension of breaker terminals for connection
of aluminum busduct with flange.-1 Nos - - - -
B) Busbar: - - - -
400A, TPN Aluminium Busbar Chamber for the entire length of the Panel as per
specification - - - -
C) Bus coupler : - - - -
1 Nos. 400 A, 4P, MCCB without any relays or protection. This is to be used only for
breaking and making the section. 1 Set of auxilliary contacts and 1 Set of LED based
indication lamps for ON, OFF & TRIP indications and suitable extension of breaker
terminals for connection of aluminum busbars. - - - -
D) Outgoings : - - - -
310Amps 4P MCCB with Thermal O/L and Magnetic S/C Protection and suitable
extension of breaker terminals.-2 NOS. - - - -
250Amps 4P MCCB with Thermal O/L and Magnetic S/C Protection and suitable
extension of breaker terminals.-5 NOS. - - - -
200Amps TPN MCCB with Thermal O/L and Magnetic S/C Protection and suitable
extension of breaker terminals.-3 NOS. - - - -
125 Amps 4P MCCB with Thermal O/L and Magnetic S/C Protection .- 6 NOS. - - - -
APFCR Panel - - - -
Supply erection testing and commissioning of floor mounted type APFC panel shall be Nos.
powder coated with 1.6mm thick CRCA plain balck sheet steel enclosure. 1No Digital
6 MR electronicmeter to indicate V,A,F,and three Phase Indication lamps,The busbar rating
shall be of 400A rating aluminium bus bar. (Above & including 125A MCCB are DN
series & 35KA Rating, upto & including 63A MCCB are DH series & 25KA Rating and
4pole MCCB are DNX series 50KA) 2.00 2,48,202.08 - 4,96,404.16
INCOMING: - - - -
310A, TP MCCB - 1 No - - - -
OUTGOING: - - - -
a) 250A TP MCCB, 36 KA-1 Nos - - - -
b) 125A TP MCCB 36KA-2 Nos - - - -
d) 14 stage Automatic powerfactor correction relay with following arrangement for
power factor controlling - - - -
f) 1 Set of 110A heavy duty Contactor and 50 KVA capacitor - - - -
g) 2 Set of 70A heavy duty Contactor and 25KVA capacitor - - - -
AC Panel-1 - - - -
51 Signature of Contractor with Seal/ Stamp
BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Supply and erection of the board consisting of: INCOMER: 250A TPN MCCB - 1 Nos.
No.Digital electronicmeter to indicate V,A,F with three phase
7 MR Indication lamp, etc. OUTGOING: 125A TPN MCCB - 4 Nos; 100A TPN MCCB - 2 Nos;
80A TPN MCCB - 6 NosThe busbar rating shall be of 250A rating aluminium bus bar.
1.00 2,13,967.31 - 2,13,967.31
Street Lighting Panel - - - -
Supply and erection of the board consisting of INCOMER : 125A TPN MCCB -1No. Nos.
Digital electronicmeter to indicate V,A,F with three phase Indication lamp, etc.,
OUTGOING : 63 A TPN MCCB with timer switch - 5 Nos, timer switch for automatic
8 MR switch on/off operation of street lights, The busbar rating shall be of 200A rating
aluminium bus bar. (Above & including 125A MCCB are DN series & 35KA Rating,
upto & including 63A MCCB are DH series & 25KA Rating and 4pole MCCB are DNX
series 50KA) (including arranging for rule-63 inspection and obtaining safety certificate
from CEIG) 1.00 1,80,287.27 - 1,80,287.27
125A TPN MCCB - 1 No - - - -
63A TPN MCCB - 5 Nos - - - -
Electronic meter for VAF - 1 No - - - -
RO PLANT /WATER PUMPS PANEL - - - -
Supply and erection of the board consisting of INCOMER : 250A TPN MCCB -1No. Nos.
Digital electronicmeter to indicate V,A,F with three phase Indication lamp, etc..
OUTGOING : 63A TPN MCCB with DOL STARTER - 3 Nos., 32A TPN MCCB with DOL
9 MR Starters- 6 Nos, The busbar rating shall be of 250A rating aluminium bus bar. (Above
& including 125A MCCB are DN series & 35KA Rating, upto & including 63A MCCB are
DH series & 25KA Rating and 4pole MCCB are DNX series 50KA)
1.00 1,84,546.81 - 1,84,546.81
250A TPN MCCB - 1 No - - - -
63A TPN MCCB with DOL Starters - 3 Nos - - - -
32A TPN MCCB with DOL Starters - 6 Nos - - - -
Electronic meter for VAF - 1 No - - - -
Transformer Fencing - - - -
Providing Metering Yard ( 5 x 6 Mts ) arrangment in welded mesh with opening of set
50mm x 50mm fabricated in 12 swg steel wire to height of 2.45mtrs with suitable MS
10 MR angle iron frame and suitable stiffners for the yard with two separate gate with lock for
consumer and suppliers as per CEIG regulation and duly providing fencing earth
arrangement with two coat of aluminium paint over coat of red oxide primer.
1.00 81,228.33 - 81,228.33
Providing HT / transformer yard fencing (10m x 11m) arrangment in welded mesh set
with opening of 50mm x 50mm fabricated in 12 swg steel wire to height of 2.45mtrs
11 MR with suitable MS angle iron frame and suitable stiffners for the yard with two separate
gate with lock as per CEIG regulation and duly providing fencing earth arrangement
with two coat of aluminium paint over coat of red oxide primer.
1.00 1,33,729.57 - 1,33,729.57
Safety equipments: - - - -
supply and delivery of the following safety equipments with allied materials as required Set
12 MR
by the statuary authority like CEIG. 1.00 29,717.68 - 29,717.68
a. First aid box big size as per standard - 2 sets. - - - -
First aid resuscitation chart laminated both in local language and english - 4 sets.
b.
- - - -
CO2 Fire extingusier(6.0Kg) - 4nos - - - -
M V Cable - - - -
Supply of following size of approved make, 650 / 1100 V grade XLPE insulated with
PVC inner sheath steel armouring and with an outer protective sheath of flame
MR retardant low smoke (FRLS PVC) compound, conforming to IS: 7098 (PartI) cables
shall have high conductivity stranded aluminium or copper conductors and cores colour
coded to the Indian standards. - - - -

52 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
The cables shall be laid in concrete trenches or buried directly underground or on cable
trays. The cost of the cable trays or ladders, excavation and back filling of trenches will
be measured separate. The unit cost of the cable shall include clamps, fasteners,
saddles, tags etc. as required for proper instllation. - - - -
13 a 3.5 Core 400 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Al.cable Metre 165.00 1,037.15 - 1,71,129.75
14 b 4 Core 4 Sq.mm, XLPE / FRLS , 1.1 KV grade. copper cable Metre 210.00 145.62 - 30,580.20
15 c 3 Core 1.5 Sq.mm, XLPE / FRLS ,1.1 KV gr. copper cable Metre 65.00 49.53 - 3,219.45
16 d 4 Core 1.5 Sq.mm, XLPE / FRLS , 1.1 KV gr. copper cable Metre 95.00 62.41 - 5,928.95
17 e 10 Core 1.5 Sq.mm, XLPE / FRLS , 1.1 KV gr. copper cable Metre 40.00 160.48 - 6,419.20
18 f 12 Core 1.5 Sq.mm, XLPE / FRLS ,1.1 KV gr. copper cable Metre 40.00 193.16 - 7,726.40
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
7.1 grade of following size direct in ground including excavation, sand cushioning,
protective covering and refilling the trench etc as required. - - - -
19 7.1.1 Upto 35 sq. mm Metre 450.00 195 - 87,750.00 -
20 7.1.2 Above 35 sq. mm and upto 95 sq. mm Metre - 202 - - -
21 7.1.3 Above 95 sq. mm and upto 185 sq. mm Metre - 210 - - -
22 7.1.4 Above 185 sq. mm and upto 400 sq. mm Metre 165.00 233 - 38,445.00 -
End termination and connection of XLPE (FRLS) aluminium / copper conductor
armoured UG cable including supply of single compression, type tinned brass cable
DSR
glands, suitable size tinned copper criumping type lugs, including gland earthing as
required. - - - -
23 9.1.31 3.5 Core 400 Sq.mm XLPE FRLS ZH A2XFY, 1.1 KV grade Al.cable Each 8.00 1369 - 10,952.00 -
24 MR 4 Core 4 Sq.mm, XLPE / FRLS , YWY, 1.1 KV grade. copper cable Each 24.00 161.47 - 3,875.28
25 MR 3 Core 1.5 Sq.mm, XLPE / FRLS , YWY, 1.1 KV gr. copper cable Each 16.00 161.47 - 2,583.52
26 MR 4 Core 1.5 Sq.mm, XLPE / FRLS , YWY, 1.1 KV gr. copper cable Each 18.00 161.47 - 2,906.46
27 MR 10 Core 1.5 Sq.mm, XLPE / FRLS , YWY, 1.1 KV gr. copper cable Each 5.00 139.67 - 698.35
28 MR 12 Core 1.5 Sq.mm, XLPE / FRLS , YWY, 1.1 KV gr. copper cable Each 5.00 162.46 - 812.30
Cable joint kit - - - -
Supplying and making indoor cable end termination with heat shrinkable jointing kit Each
29 10.4.2 complete with all accessories including lugs suitable for following size of 3 core 120 4868
sq.mm XLPE aluminium conductor cable of 11KV grade. 6.00 - 29,208.00 -
Supplying and making outdoor cable end termination with heat shrinkable jointing kit Each
30 10.5.2 complete with all accessories including lugs suitable for following size of 3 core 120 8185
sq.mm XLPE aluminium conductor cable of 11KV grade. 12.00 - 98,220.00 -
EARTHING SYSTEM - - - -
Earthing with copper earth plate of 600 X 600 X 3mm thick including accessories, and Set
providing masonary enclosure with cover plate having locking arrangement and
31 5.6 9292
watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required.
44.00 - 4,08,848.00 -
Earthing with G.I. earth pipe 4.5 meter long, 40mm dia including accessories, and Each
32 5.2 providing masonary enclosure with cover plate havng locking arrangement and 3926
watering pipe etc., with charcoal / coke and salt as required. 64.00 - 2,51,264.00 -
Supply and laying of following types of earthing conductor and inter connecting the
equipments, DBs, Switch boards including earth pit. - - - -
50mm x 6mm GI strip along cable trays, & looping with DBs / SBs. Including forming Metre
33 MR earth grid. As per DSR(E) of CPWD and as per the direction of engineer- in-charge.
830.00 118.87 - 98,662.10
Providing and fixing 25mm x 5mm G.I.Strip on surface or in recess for connection etc. Metre
34 5.15 142
as required 1,025.00 - 1,45,550.00 -
- - - -
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connection Metre
35 5.14 856
etc. as required 680.00 - 5,82,080.00 -
50mm x 6 mm Copper strip for Transformer & DG Neutral earthing. As per the Metre
36 MR
manufacturer specification and as per the direction of engineer- in-charge. 60.00 792.47 - 47,548.20

53 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Providing and fixing of 4.00mm dia copper wire on surface or in recess for loop Metre
37 5.19 earthing along with existing surface/recessed conduit/submain wiring/cable as 86
required. 260.00 - 22,360.00 -
Providing and fixing 6SWG dia G.I wire on surface or in recess for loop earthing as Metre
38 5.16 35
required. 1,030.00 - 36,050.00 -
Providing and fixing earth bus of 50mm x 5mm copper strip on surface for connections Metre
39 5.2 1599
etc. as required 100.00 - 1,59,900.00 -
MISCELLANEOUS - - - -
Providing and fixing MV danger notice plate of 200 mm X 150mm made of mild steel, Each
40 2.21 at lease 2mm thick and vitreous enamelled white on both sides and with inscription in 141
single red color on front side as required. 32.00 - 4,512.00 -
Providing and fixing HT danger notice plate of 250mm x 200mm made of mild steel, at Each
41 2.22 least 2mm thick and vitreous enamelled white on both sides and with inscription in 155
single red colour on front side as required. 2.00 - 310.00 -
42 MR Supply of 11 KV grade, electrician rubber gloves for switch gear operation Pair 5.00 551.76 - 2,758.80
Providing and fixing in position approved shock treatment chart written in English and Each
43 MR Local Language. The chart shall be framed in Teakwood and covered with glass.
2.00 842.00 - 1,684.00
Providing and fixing in position 15 mm thick 11KV grade, rubber mat and as per sq.ft
44 MR
relevant IS. 40.00 104.01 - 4,160.40
Cable Tray and Supports : - - - -
supplying and installing following size perforated pre-painted M.S.cable trays with
perforation not more than 17.5%, in convenient sections, jointed with connectors,
4.1
suspended from the ceiling with M.S suspenders including bolts & nuts, painting
suspenders etc as required - - - -
45 4.1.4 300mm width x 50mm depth x 1.6mm thickness Metre 820.00 789 - 6,46,980.00 -
46 4.1.6 450mm width x 50mm depth x 1.6mm thickness Metre 230.00 1117 - 2,56,910.00 -
47 4.1.7 600mm width x 50mm depth x 1.6mm thickness Metre 45.00 1386 - 62,370.00 -
48 4.1.16 900mm width x 75mm depth x 2.0mm thickness Metre 45.00 2038 - 91,710.00 -
Supply, Installation, Testing & Commissioning of following size hot dip galvanized Kg
ladder type cable tray made out of 2.0 mm thick sheet steel incase of perforated and
49 MR 2.5 mm thick sheet in case of ladder type, folded to required shape, including suitable
number of inward / outward bends, Tees, couplers, clamps and fasteners as covered in
the specification and as per the direction of engineer-in-charge.
1,100.00 89.15 - 98,065.00
HT CABLE - - - -
Supply of 3 x 120sqmm 11KV HT XLPE aluminium UG cable Earthed with conductor Metre
screened with exturded semi conducting compound XLPE insulated, insulation
50 MR screened with semi conducting compound in combination with copper Tape (0.3 LA for
one sec) cores laid up, inner sheath of PVC Tape, Galvanished steel flat strip
Amounred and over all PVC sheathed cable confirming to IS 7098/II/85 with latest
amendment. 180.00 1,703.81 - 3,06,685.80
3x120 sq mm 11KV XLPE (E) cable - - - -
Laying of one Number PVC insulated and PVC sheathed / XLPE Power Cable of 11KV
8.1 grade of following size direct in ground including excavation,sand cushioing,protectiive
covering and refilling the trench etc as required - - - -
51 8.1.2 Above 120sq.mm and upto 400 sq.mm Metre 60.00 278 - 16,680.00 -
Cable trench - - - -
Excavation of cable trenches in soft soil, depth upto 1.2m including dressing of sides Cum
lift upto 1.5m, including getting out the excavated soil, refilling with sand and or good
52 14.4 soil after laying of cable / pipe etc in layers of 20cm, ramming, watering and disposal 285
of surplus excavated soil as directed, within a lead of 50 meters.
740.00 - 2,10,900.00 -

54 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
Excavation of the cable trenches in hard rock not exceeding 1.5 meters in width, and Cum
53 14.6 lift upto 1.5 meters, including getting out the excavated soil and disposal of excavated 528
soil as directed within a lead of 50 meters. 450.00 - 2,37,600.00 -
GI PIPE - - - -
Providing , laying and fixing following dia. G.I. Pipe(Medium class) in ground complete
54 14.13 with G.I. fitting including trenching(75cm deep) and re-filling etc. as required
- - - -
14.13.1 i) 50mm dia Metre 170.00 450 - 76,500.00 -
14.13.3 ii) 100mm dia Metre 105.00 983 - 1,03,215.00 -
Hume Pipe - - - -
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground
14.14 complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand)
including trenching (75cm deep) and refilling tec as required. - - - -
55 14.14.4 300mm dia Metre 195.00 566 - 1,10,370.00 -
Conventional Lightning Arrestor - - - -
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, Each
56 6.1 copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate 764
including holes etc. complete as required. 2.00 - 1,528.00 -
Providing and laying G.I. tape 32 mm x 6 mm from earth electrode directly in ground Metre
57 6.14 141
as required. 20.00 - 2,820.00 -
Providing and constructing of MV Panel trenches in BW with CM 1:6 of 230mm wall Metre
thickness with bottom PCC 1:4:8 filling of 100mm thick including plastering the all
58 MR internal surfaces with CM 1:4, 12mm thick etc complete as per all standards and as
directed by engineer in charge etc. the rate inclusive of earthwork excavation in all
kinds of Soils as per required dimensions etc, complete( the clear size of trench is
700mm X 750mm ). - 2,476.47 - -
Light fitting - - - -
Supply and fixing of 150 watts LED street light fitting Philips/wipro/GE/Thron make Nos.
road light fixed with 6M height swaged 100/80/50 mm dia MS pole with Single arm
59 MR bracket for fixing of fitting including necessary SMC Junction box with 6A SP MCB and
3 core 2.5 sq.mm flexible cable from SMC Junction box to fitting and painting work.
18.00 25,845.47 - 4,65,218.46
Supply and fixing of 1 x 40 w LED lamp post top Philips/wipro/GE/Thron make lantern Nos.
60 MR fitting with 2.5M height , 60mm dia pole including all accessories as required.
12.00 16,211.99 - 1,94,543.88
Supply and fixing of 1X10 watts LED Lamp Philips/wipro/GE/Thron make pathway Nos.
61 MR
ballord light fitting including all accessories as required. 12.00 8,548.79 - 1,02,585.48
17 Mtrs HIGH MAST - - - -
Supply and erection of “METAL COATS”, High Mast Lighting, 17 Mtrs., continuously Nos.
tapered, polygonal cross section, proven in-tension design conforming to the
standards, mast fabricated out of special steel conforming to BS-EN 1-025 or
equivalent, cut and folded, telescopically jointed and fillet welded, welding in
accordance with BS:5135, mast delivered to site in sections and jointed together by
62 MR „slip-stressed-fit‟ method, mast provided with supplementary gusset arrangement to
ensure elimination of helical stress concentration, environmental protection of the mast
ensured by hot dip galvanizing both internally and externally having a uniform
thickness of not less than 70-80 microns, mast designed suitable for operation on 3
phase 400/440V AC and will be supplied with the under mentioned features and
accessories:- 2.00 45,567.11 - 91,134.22
i) An inspection door with cover arrangement, vandal resistant, provided at the
bottom housing the winch, cables, plug and socket. - - - -
ii) A lantern carriage designed for mounting 8nos. LED light with associate control gear
boxes and lamps. - - - -
iii) Raising / Lowering mechanism of lantern carriage assembly both mechanical and
electrical by built-in control and double drum winch, self-sustaining type. - - - -
55 Signature of Contractor with Seal/ Stamp
BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
iv) Head frame designed as a capping unit of the mast, welded steel construction,
galvanized both internally and externally, pulley blocks made out of die cast aluminium
alloy (LM-6) self lubricating bearings with SS shaft to facilitate smooth and
maintenance. - - - -
v) 3 point suspension systems by means of stainless steel wire rope AISI-316 grades
8mm, without any intermediate joint. - - - -
vi) Electrical system with plug and socket. - - - -
vii) Lighting finial. - - - -
viii)Supply of template for casting foundation and foundation hardwares. - - - -
ix)Supply of complete set of drawings for casting foundation including supply of
service manual on completion of work. - - - -
x) M.S. Control Box, weather proof design, with all electrics pre-wired including
provision of timer device for automatic switching on / switching off the lights, system
designed for operation on 3 – phase 400/440V A/C - - - -
xi)Foundation Cost for standard soil. - - - -
xii)1x150W LED lamp 8Nos (included). - - - -
xiii)TwinAviation light with GLS lamp (included). - - - -
SUPPORTS - - - -
i) Fan down rod-HEAVY DUTY - - - -
ii) FAN CLAMP - - - -
- - - -
AVIATION OBSTRUCTION LIGHT - - - -
Supply and fixing of AVIATION OBSTRUCTION LED TYPE LIGHT FITTING (K-LITE 6649) Nos.
63 MR
2.00 2,354.63 - 4,709.26
Advanced Lightning Arrestor - - - -
Supplying, erecting, connecting and commissioning the Advanced Dynosphere,with the nos.
following and necessary foundation plate, mounting screws / bolts, andother
associated accessories to complete the system to function. 75KV 36mm dia special
copper cable ( only meant for these applications ) in GI pipe for protection of the cable
64 MR with necessary accessories as required . Eath Gel in the Earth Electrode with necessary
accessories as required by the system. a Lightning Event Counter of digital type in
weather proof enclosure with necessary accessories. Tesing and commissioning of the
System (Lumpsum)
1.00 1,58,217.93 - 1,58,217.93
Solar Street Lighting - - - -
Supply and erection of 24W LED Luminary with electronics system for street light Each
fixed with 6M height swaged 100/80/50 mm dia MS pole with Single arm bracket for
fixing of fitting including necessary SMC Junction box with 6A SP MCB and 3 core 2.5
65 MR sq.mm flexible cable from SMC Junction box to fitting and painting work etc.and 10-
12Hrs battery backup (12V / 100AH and battery, and solar PV Module, street light pole
cable, with sensor for automatic on / off operation and accessories complete.
11.00 1,24,939.08 - 13,74,329.88
66 MR Remote ON Locable OFF Push Button Station Each 12.00 742.94 - 8,915.28
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 Each
coarse : 4 graded stone aggregate 20 mm nominal size) of size 60 cmm x 60 cm at
67 7.9 310
the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including
inscription duly engraved as required. 5.00 - 1,550.00 -
Supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick G.I. Pipe Each
68 7.10 with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60cm 288
long and fixing the same in ground as required. 41.00 - 11,808.00 -
69 MR Supply and installation of Cable turf. Mtr. 30.00 267.46 - 8,023.80
Providing of rubber mat 1 mtr wide and 6 mm thick for MV Panels as per relavent Mtr.
70 MR
standards 26.00 990.59 - 25,755.34
External Electrical Sub Total - 37,06,390.00 123,79,276.91
Total (INTERNAL AND EXTERNAL) - 268,01,975.00 409,42,684.67

56 Signature of Contractor with Seal/ Stamp


BoQ ANGRAU - Annexe Bldg. Guntur

S. No.
REF. DSR RATE (Rs.) AMOUNT (Rs.)
- 2014/ DESCRIPTION OF ITEM UNIT Total Qty
NS
DSR NON - DSR DSR ITEMS NON - DSR
HVAC WORKS -
MR Loading & Un loding of truck, Supply, Erection, Testing & Commissioning of Air Nos
1 Handling Unit, Compact Floor mounted OR otherwise specified, Air Handling units with
copper coil 39.5 Tr Ahu With19750 Cfm 2.00 4,82,119.86 - 9,64,239.72
DX DUCTABLE UNIT - - - -
MR Supply, Lifting, shifting , Erection, Testing & Commissioning of Ductable split air
2 conditioners of below mentioned capacities with Scroll Compressor.with R- 410 a
refrigerant - - - -
a 8.5 TR Ductable out door unit Nos 8.00 1,98,563.65 - 15,88,509.20
b 5.5 TR Ductable out door unit Nos 2.00 1,27,082.71 - 2,54,165.42
COPPER PIPE - - - -
MR Supply, Installation, Testing & Commissioning of 18 SWG hard drawn copper
3
refrigerant piping with its necessary accessories and insulation - - - -
a 1/2" Rmt 80.00 715.30 - 57,224.00
b 5/8" Rmt 80.00 908.12 - 72,649.60
c 7/8'' Rmt 80.00 624.57 - 49,965.60
d 1-1/8" Rmt 80.00 1,157.65 - 92,612.00
4 POWER and CONTROL CABLES - - - -
MR Supply and laying of 6 core x 1.5 Sq.mm copper cable from the Panel to Outdoor unit Rmt
a ( for In coming power supply )
150.00 272.46 - 40,869.00
MR Supply and laying of 4 core x 6 Sq.mm copper cable from the Panel to Outdoor unit Rmt
b ( for In coming power supply )
200.00 431.25 - 86,250.00
5 DRAIN PIPING - - - -
a MR Providing and fixing in position the following PVC -shd 40 blue threaded pipes for drain Rmt 95.00 329.17 - 31,271.15
6 cutDUCTING-RECTANGULAR
GI to required lengths and installed complete with all necessary fittings like elbows, - - - -
MR Supply, installation, of Rectangular GI Ducting made of Lock- forming quality GSS; - - - -
a complying
22 Gauge with IS: 277 and having 120GSM coating classification with necessary Sqm 175.00 1,418.52 - 2,48,241.00
b 24 Gauge Sqm 265.00 1,191.68 - 3,15,795.20
c collar damper Sqm 14.00 4,541.85 - 63,585.90
7 MR CONTINUOUS EXTRUDED ALUMINUM GRILLS - - - -
Air grilles for air-conditioned areas fabricated out of Extruded Aluminum, powder - - - -
a coated
8" sections,
Continuous with
grill forcolor matching
Supply Air to the interiors. Sqm 15.00 9,078.75 - 1,36,181.25
b 8" Continuous grill for Return Air Sqm 22.00 9,078.75 - 1,99,732.50
8 MR THERMAL INSULATION FOR DUCTS - - - -
Supply and fixing of Thermal Insulation with nitrile rubber - 19mm Thickness Sqm 370.00 1,407.68 - 5,20,841.60
9 MR ACOUSTIC INSULATION FOR DUCTS - - - -
Supply and application of acoustic insulation of ducts with Antifungal microban, open Sqm 70.00 2,269.94 - 1,58,895.80
10 MR cell, elastomeric,
Nitrogen Pressurenitrile
Testingrubber
& R- with
410 a15Refrigerant
mm Thickness
gas topping at site lot 1.00 73,774.15 - 73,774.15
TOTAL for HVAC WORKS - 49,54,803.09

57 Signature of Contractor with Seal/ Stamp

Das könnte Ihnen auch gefallen