Extinguishant
Control Panels

Sigma XT Sigma XT+ Syncro XT+


Abort Unit
Protection of people, building and assets from a fire
is a paramount concern to any organisation. Keeping Sigma XT Sigma XT
a site safe is not the only priority but with the risk of
physical damage and financial loss resulting from a fire,
Extinguishant Connection Diagram Hold Off Unit
there is also the risk to operational performance and
reputation, so a reliable and responsive fire system is
Control Panel
required that can respond rapidly to any situation.
1st Stage 2nd Stage Manual Mode Switch
Sounders Sounders
For many businesses such as data centres, museums
and heritage sites, the right protection not only
needs to protect your investment but also ensure
Manual Release
uninterrupted business operations.
RS485
Manual Release
Early warning fire extinguishant systems and detection
technology can detect a fire and automatically release
a fire suppression agent to eliminate fire within
Hold Off Unit
K1822
seconds. Stopping a fire within the first few moments Sigma Si Weatherproof Sigma Si

Released Pressure Switch


Ancillary PCB StatusDoor
UnitInterlock Status Unit

Activate Extinguisher
can reduce or avoid damage to equipment and assets

Low Pressure Switch


and subsequent loss of operational productivity.
Up to 7 per Up to 7 per
area. area.
Globally established, Kentec, a leading manufacturer The industry-leading Sigma XT extinguishant releasing panel
of life-critical control systems, has a range of provides outstanding value and performance for all small to
extinguishing control panels which play a key role medium fixed firefighting installations.
in protecting vitally important information and assets.
With three detection zones as standard, extinguishant K555

In
Network Card
Required
release can be configured to activate from any combination
of detection zone inputs.
Con
Sigma XT panels are robust and easy to install, with all the
electronics mounted on a single, easily removable, steel plate.
N
Sigma XT - EN12094-1
Approved Control Unit

Sigma XT Features
Vizulinx
Any single zone or any combinations of zones can be Fire alarm management

4 Core (FP200 max. length 1200m)


solution

configured to release
Control panels
Configurable first stage sounder delays are supplied
Hold Off Unit BMS with 1 or 2 detection
Configurable detection delays Interface
2 Core Syncro XT+ loops and 16
zone indicators.
Zero time delay upon manual release option 2 Core Multi Area Addressable
Compatible with I.S. barriers Extinguishant Control Panel
Door Interlock The Syn
system
with Ap
Non-latching zone input option to receive signals from protoco
4 Core
other systems such as aspirating equipment panels
protoco
Countdown timer displays time remaining until release togethe
Status Unit Ancillary Board
Supports up to seven, four-wire status indicators
Vizulinx
Fire alarm management
solution
Addressable
Approved and certified to EN12094-1, EN54-2 and EN54-4 House Fire Alarm

UL and FM Approved version also available

Detection Detection Detection


Zone 1 Zone 2 Zone 3

Electronics Ltd
Ancillary Board Status Unit Status Unit Status Unit

2 3
Sigma XT+ Multi-Area Syncro XT+ Multi-Area
Extinguishant Control Panel Addressable Extinguishant
Control Panel
The Sigma XT+ range combines Sigma CP conventional fire Syncro XT+ multi area addressable control panel enables Syncro XT+ features
detection from two to eight zones with highly configurable extinguishing systems to use all the features and benefits Up to four extinguishant areas (custom build options
extinguishing control modules. It provides an integrated of the more sophisticated detection techniques provided are available)
control solution for extinguishing systems with up to four by addressable fire detectors, as well as the other benefits Dual extinguishant outputs for each area
protected areas. of analogue addressable systems, such as control of loop (configurable as main/reserve)
connected sounders, beacons and input/output modules. First and second stage sounder outputs for each area
The fire detection section connects to the extinguishant control With up to 16 zones of addressable detection over one or First and second stage volt-free changeover contacts
modules via a serial link which enables secure, bi-directional two loops it ensures every detector can contribute to the for each area
transfer of data. Sigma XT+ modules may be mounted remotely extinguishant release. Released volt-free contact per area
in separate enclosures and connected to Sigma CP panels via Fault volt-free contact per area
this serial interface to provide central fire detection and control The Syncro XT+ has up to four extinguishing areas and two Programmable extinguishant delays
with distributed extinguishing systems. releasing outputs per area which can be controlled via simple Programmable output duration
coincidence detection or via more complex cause and effects Countdown indicator shows time until release in seconds
Sigma XT+ modules may also be mounted separately from fire configured by the Loop Explorer configuration programme. Mode select and manual release controls per area
detection and control equipment and activated by addressable Each extinguishant area features a comprehensive set of Serial connections for Sigma Si status units and ancillary
output modules or volt-free contacts from other systems via inputs and outputs and is configurable via the Loop Explorer boards (K588)
two monitored activation inputs. configuration programme. Approved and certified to EN12094-1, EN54-2 and EN54-4

Sigma XT+ Features All extinguishant areas may have up to seven serially
Two, four or eight detection zones connected Sigma Si status indication and control units,
One to four extinguishant areas or ancillary relay boards connected via a four-core cable.
Dual extinguishant outputs for each area With the addition of a Syncro network card, Syncro XT+ control
(configurable as Main/Reserve) panels can be networked to provide scalable extinguishing
First and second stage sounder outputs for each area systems for all sizes of installation.
First and second stage volt-free changeover contacts
for each area
Released volt-free contact per area
Fault volt-free contact per area
Programmable extinguishant delays
Programmable output duration
Countdown indicator shows time until release in seconds
Mode select and manual release controls per area
Monitored remote manual release input,
Abort input & Hold input
Approved and certified to EN12094-1,
EN54-2 and EN54-4

4 5
Syncro XT+ Sigma Si Extinguishant
Network Diagram Status Units & Hold-Off Unit
The Syncro XT+ Multi Area Addressable Fire Alarm Control Panels are Approved to EN12094-1, EN54-2 and EN54-4 - KM 96761

Typical Extinguishing Area Connections Fire Area Connections Status Units Hold-Off Units
Sigma Si is a range of system status indicator units for use Sigma Si Hold-Off units are available with red or green
1st Stage Sounders Syncro Si Addressable
Status Unit & Syncro
Addressable Hold Off A mixture of up to 32 devices
with Kentec Sigma XT, Sigma XT+ and Syncro XT+ extinguishant actuators (BS 7273-1 recommends white with red button)
Unit on Apollo loop only. (including Syncro View, Ident
and Matrix) can be fitted to each
panel on the RS485 serial interface.
releasing control panels. and are mounted in a single gang, surface mounting enclosure.
2nd Stage Sounders The maximum number of Syncro
Loop 1 Loop 2 View panels on a single RS485
serial interface is 15.
For flush mounting, the enclosure may be discarded and the
Each loop is
capable of hosting The Sigma Si range of status indicators provide detailed status unit mounted to a standard UK single gang electrical back box.
Main Release
I/O up to:
126 devices (Apollo) or
127 devices (Hochiki) information for Sigma XT and Sigma XT+ extinguishant release The unit has a durable, shrouded push button to prevent
control equipment. accidental operation and a simple two-wire connection to
Optional Reserve Release
Sigma XT, Sigma XT+, Syncro XT+ or Sigma Si status units
is required.
Can be
Low Pressure configured Syncro Matrix
as 1st stage Fire Alarm Mimic
sounders
Display System
(if fitted)
Loop 1 Loop 2
Sigma Si Hold-Off units are fitted with normally open and
Release Pressure 24V DC or
230V AC normally closed contacts to allow operation with monitored
and unmonitored systems.
Abort Unit

I/O Warning Signs


Syncro Ident
Hold Off Unit
Programmable LED Powered by a nominal 24V DC supply, the illuminated
Indication Panels
warning signs use LED technology to provide a high reliability,
24V DC or
230V AC high brightness, audio/visual warning indication unit to
supplement mandatory alarm warnings.
Manual Mode Switch K555
Network Card
Required

Status Unit Features


Manual Release High brightness LEDs The brightness of the sign remains constant over its entire
RS485 Syncro View
Local LCD Repeater Detailed indication of the status of the control panel operating range of 15 to 30 volts DC due to the unique ‘power
Monitored data connection boost’ circuitry employed. This ensures that even with a system
24V DC or

K1822
230V AC Countdown timer displays time remaining until release running on depleted batteries, all signs remain at full intensity.
Sigma Si Weatherproof Sigma Si
Ancillary PCB Status Unit Status Unit
Manual only, automatic and manual mode
Syncro XT+
Multi Area Addressable K545 Remote auto/manual door interlock input (monitored) A range of standard text signs are available, including
Up to 7 per Up to 7 per
Extinguishant Control Panel 4 Way Conventional
Remote hold input (monitored) automatic/manual mode, manual only mode, automatic
area. area.
Zone Board 24V DC

Internal fault diagnosis indicators model only, and extinguishant system activated. All signs

K555
High K555
Weatherproof IP65 versions available have fully customised text and different languages are easily
Integrity
Network Card

Certified compliant with BS EN12094-1 when used accommodated. The large display panel is backlight with high
Network Card
Required Required
K546
6 Way
Configurable Sounder Board
24V DC with Sigma XT control equipment intensity white LEDs to provide a high contrast indication

Network in a range of different colours.


RS485

K547 A split-level function allows the top and bottom halves of the
8 Way
Relay Board 24V DC sign to be illuminated independently via separate inputs or by
Control panels
are supplied
with 1 or 2 detection
Up to 64 Panels
can be added to reversing the supply voltage allowing two stage messages to
Syncro XT+ loops and 16 the network.
be displayed if required.
zone indicators.
Multi Area Addressable
Extinguishant Control Panel The Syncro XT+
system is compatible
with Apollo, and Hochiki K560
protocols. Syncro XT+ Syncro XT+ 16 Channel
panels of either the above
protocols can be networked
together.
Multi Area Addressable
Extinguishant Control Panel
I/O Board
24V DC The internal buzzer can be enabled or disabled via
Vizulinx
Fire alarm management
solution
configuration switches and it can be silenced via a two-wire
remote input. The metal enclosure is slimline and attractively
Syncro XT+ Multi-Area Addressable finished in a durable, neutral epoxy powder coat.
Extinguishant Control Panels

Electronics Ltd
The Syncro XT+ Fire Alarm Control Panels are
Approved to EN12094-1, EN54-2 and EN54-4
6 7
Company
Overview

Kentec Electronics is one of the world’s leading life


safety solutions manufacturers of conventional, analogue
addressable fire detection and extinguishant control panels.

Founded in 1985, Kentec is an end-to-end manufacturer,


with everything sold being made in the UK. It employs
approximately 230 members of staff in its production facility,
head office and research and development department.

In addition to design and manufacture, Kentec provides


technical support specified to the local standards
and customer requirements of over 90 countries worldwide.
With a commitment to meeting the needs of individual
national markets, Kentec has achieved a global reputation,
resulting in its life safety systems being installed Kentec manufactures products approved to EN54,
in numerous prestigious sites across the world. EN12094, UL, FM, NFPA and marine classification societies.

TM
TM

Units 25-27 +44 (0)1322 222121


Fawkes Avenue +44 (0)1322 291794
Questor Dartford sales@kentec.co.uk
Kent DA1 1JQ, England www.kentec.co.uk

This briefing is intended as general guidance and is not a substitute for detailed advice in specific circumstances. Although great care has been
taken in the compilation and preparation of this edition to ensure accuracy, Kentec cannot in any circumstances accept responsibility for errors,
omissions or advice given or for any losses arising from reliance upon information contained in this publication.

© Kentec Electronics Limited 2018

Das könnte Ihnen auch gefallen