COLUMN AND BEAM DESIGN FOR DEAD LOAD, LIVE LOAD & SEISMIC LOAD

DEAD LOAD:

SELFWEIGTH__________ AUTOMATIC

CORRUGATED ROOF__________ 0.1 KPA

MEP&CEILING__________ 0.2 KPA

SEMI TRUSS & RAFTERS__________ 0.18 KPA

PARTITION LOADS__________ 1.0 KPA

FLOOR CONCRETE__________ 23.5KN/M3

CHB,150MM,FULL GOUT,PLASTER BOTH FACE_____________ 3.11KPA/M

FLOOR FINISH__________ 1.1 KPA

LIVE LOADS:

ROOF__________ 0.6 KPA

RETAIL STORES__________ 4.8 KPA

SEISMIC PARAMETERS:

LOCATION TO NEAREST FAULT__________________________ 26 KM MORE OR LESS

ZONE_______________ 4.0

SEISMIC SOURCE TYPE_______ A

NEAREST SOURCE FACTOR, Na'____________________________ 1.0

NEAREST SOURCE FACTOR, Nv'____________________________ 1.0

CODE____________________________ UBC 1997

IMPORTANCE FACTOR____________________________ 1.0

RW IN X DIRECTION____________________________ 8.5

RW IN Z DIRECTION____________________________ 8.5

SOIL PROFILE TYPE____________________________ 4

Z____________________________ 0.4

CT____________________________ 0.0731
STORY DRIFT________________________________ 0.036

DESIGN DATA USE:

COMPRESSIVE STRENGTH OF CONRETE_______ 20.5 MPA

YEILD STRENGTH OF STEEL____________________ 275 MPA

UNIT WEIGHT OF CONCRETE_____________ 23.5 KN/M3

CONCRETE DESIGN PARAMETERS:

CODE________________ ACI 318 2011

COLUMN SIDE COVER____________________ 50MM

BEAM TOP,SIDE,BOT COVER__________________ 50,40,40MM

BEAM MIN MAIN BAR SIZE____________________ 25MM

COULMN MIN MAIN BAR SIZE____________________ 16MM

COLUMN&BEAM MAX BAR SIZE____________________ 32MM

MIN STIRRUPS & TIES SIZE____________________ 10MM

STAAD RESULTS:

BASE SHEAR
STOREY DRIFT
Therefore adopt:

Column & Beam dimension, spacing and bar size shown in staad result pdf

ROOF BEAM 300X300

300X350

2ND FLOOR BEAM 300X300

400X450

400X550

400X700

600X700

1ST FLOOR BEAM 400X750

TIE BEAM 250X300

COLUMNS 300X300

400X400

700X700