PPS25 Electronic Memory Gauge

User Manual (Rev. 08)

Pioneer Petrotech Services Inc.


#1, 1431 - 40th Ave. NE
Calgary, AB T2E 8N6, Canada

Phone: 1-888-PP-GAUGE (774-2843)


E-mail: sales@pioneerps.com
Website: www.pioneerps.com
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

REVISION HISTORY

Revision Date Comments


00 2002-11-15 Initial release
01 2004-10-10 Additional information for PPS25 gauge
02 2008-04-02 Revision (metal to metal seal added to the housing)
03 2011-01-21 Revision (Release of modified field operating procedures)
04 2012-04-15 Revision (More information about accessories and maintenance)
05 2013-06-26 Revision (Update specifications and part list)
06 2014-01-09 Revision (carrying case changed for PPS25-XM)
07 2014-06-23 Revision (Circuit function block diagram)
08 2015-09-30 Revision (torque requirement for gauge assembling)

Page 1
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

REVISION HISTORY ................................................................................................................... 1


Scope ......................................................................................................................................... 3
1. Objective .............................................................................................................................. 3
2. Responsibilities ................................................................................................................... 3
2.1 Implementation ................................................................................................................................ 3
2.2 Supervision....................................................................................................................................... 3
2.3 Verification ....................................................................................................................................... 3
2.4 Verification Method .......................................................................................................................... 3
2.5 References ........................................................................................................................................ 3
3. Introduction......................................................................................................................... 4
3.1 Overview .......................................................................................................................................... 4
3.2 PPS25 Gauge ..................................................................................................................................... 4
3.3 PPS25-XM Gauge............................................................................................................................... 4
3.4 PPS25 Functional Block Diagram ...................................................................................................... 4
4. Getting Started ..................................................................................................................... 5
4.1 Working Mode of PPS25 Gauges ........................................................................................................ 5
4.2 Materials .......................................................................................................................................... 5
4.3 Inspecting Gauges ............................................................................................................................. 6
4.4 Programming Gauges ........................................................................................................................ 7
4.5 Activating and Testing Battery Packs .............................................................................................. 10
4.6 Installing Battery Pack .................................................................................................................... 11
4.7 Assembling Battery Housing ........................................................................................................... 12
4.8 Important Application Notes ........................................................................................................... 13
4.9 Downloading Data .......................................................................................................................... 14
5. Maintenance .......................................................................................................................15
5.1 Field Maintenance........................................................................................................................... 15
5.2 Manufacturer’s Maintenance ........................................................................................................... 19
6. Troubleshooting .................................................................................................................20
Appendix A: Specifications.......................................................................................................21
Appendix B: Gauge and Accessories ........................................................................................22
Appendix C: Battery Packs .......................................................................................................26
Appendix D: Power Consumption Calculation .........................................................................27

Page 2
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

Scope
This manual will apply to all operations that work with PPS25 series memory gauges.

This manual includes important information about operation of PPS25 gauges.


Please read it carefully before operating the gauges.

1. Objective
This manual is in place to assist the testing personnel involved in field operations with the required
skills for programming, deployment, retrieval, and data extraction (downloading of data files from
the tools), when working with the PPS25 series gauges.

2. Responsibilities
All personnel involved in the process of running PPS25 memory gauges, programming these gauges,
as well as downloading and processing files from them.

2.1 Implementation
The Field Service Manager and/or Location Manager will ensure that this procedure is implemented.

2.2 Supervision
The Field supervisor/Field Engineer/Field Specialist in charge of each operation will ensure this
procedure is followed.

2.3 Verification
The Testing Company Service Quality Coach, Field Service Manager and/or Location Manager will
verify that this procedure is implemented.

2.4 Verification Method


Verification is by periodic unscheduled audits of files created and sent to clients.

2.5 References
 Gauge Programming, Deployment, Downloading, and File Creation Procedures
 Gauges Control Sheet
 Battery Record Form (used to record battery usage after a job)

Page 3
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

3. Introduction

3.1 Overview
Pioneer Petrotech Service (PPS) has designed and developed downhole electronic memory pressure
gauges since 2001. A series of Silicon-Sapphire memory gauge products (PPS25) have been
developed for critical well testing in hostile well conditions.

The PPS25 pressure gauge consists of a Silicon-Sapphire pressure transducer and our advanced
electronic circuit and mechanical design. The High sensitivity and stability transducer is good for
high accuracy pressure measurement with high resolution, low drift and perfect long-term stability.

3.2 PPS25 Gauge


The PPS25 (125C/150C/177C) memory gauge is integrated with a Silicon-Sapphire pressure
transducer and PPS SMT electronics circuit. It is a good choose for applications where high data
quality is required in normal high temperature environment.

3.3 PPS25-XM Gauge


The PPS25-XM (150C/177C) electronic memory gauge is integrated with a Silicon-Sapphire
pressure transducer, PPS leading-edge high temperature electronics and metal-to-metal seal
technology. It is suitable for extreme high temperature and hostile environment.

3.4 PPS25 Functional Block Diagram

VCC

VCC

TX
Pressure Analog to
Sensor digital Microcontroller RX

GND

Memory

For information about PPS25 specifications, please see Appendix A: Specifications

Page 4
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4. Getting Started
4.1 Working Mode of PPS25 Gauges
In standard memory mode, there are three operating modes of the gauge can be in: Sampling Mode,
Stand-by Mode, and Communication Mode.

 Sampling Mode
The gauge is in Sampling Mode when a battery is connected to the gauge without the interface
box and cable attached to it. Under normal operating conditions the gauge is programmed and
then transported to the wellsite.

Prior to running the gauge in the well, the battery pack is connected to the electronics and the
gauge carries out the program in accordance with the instructions pre-stored in the memory.

 Stand-by Mode
The gauge is in Stand-by Mode when the gauge is not sampling (i.e. in between the samples).
PPS gauges are designed to switch to Stand-by Mode automatically between samples.

 Communication Mode
The gauge is in Communication Mode when the interface box and cable are connected to the
gauge and the computer. Communication Mode is used to program the gauge, download data
from the gauge, and perform other related operations through the software.

4.2 Materials

Please see Appendix B: Gauge and Accessories for details.

 PPS USB programming/download interface


 PPS25 memory gauges
 Lithium battery pack
 Open-end wrench and torque wrench
 O-ring grease

Page 5
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.3 Inspecting Gauges


To ensure gauges are functional, a regular inspection (Bench Test) is
necessary before each operation.

PPS SmartView software can be used to test the gauges before a field operation.

Please refer to “PPS SmartView User Manual” for more detail.

Procedure:
(1) Complete a bench test by plugging in a battery pack for 10mins;
(2) Connect a PPS USB download interface to the gauge (Fig. 1) and a computer to download
data and check if the record data is normal;

Your gauges may have a different receptacle (4-pin or 6-pin), please make sure
you are using a proper plug on the USB interface for connection.

Fig. 1

(3) Run SmartView and use “Diagnostics” in Options Tab to test the gauge (Fig. 2).
 Click “Start” Button

Fig. 2

The pressure and temperature reading should be reasonable at atmospheric


pressure and ambient temperature.

Page 6
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.4 Programming Gauges

Use Gauges Control Sheet program gauges according to the client request. All control sheets must be
maintained for each gauge set until the files are given to the client.

Gauge Programming Procedure:

(1) Select the Program tab (Fig. 3)

Fig. 3

(2) PPS SmartView software will display the tool program. To make sure that there is no doubt
regarding the tool program you can verify it by clicking Clear all Steps and then Get
Program from Tool.

If the program is the same as the one that is needed for the current job, just click Program
Tool and choose YES in order to clear all previous jobs from the gauge memory (Fig. 4)

Make sure that the files have been previously downloaded, as this is an irreversible process.
It is a good rule of thumb to download previous files if you are in the field, thus being unable
to check if these files were downloaded.

For information about programming gauges, please refer to SmartView User Manual.

Page 7
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

Fig. 4

If the program is not the same as the one desired for the job to be done, click Clear All Steps,
then complete the fields for the required gauge sampling rate, and then click Program the
Tool (Fig. 5).

Fig. 5

Please make sure the battery pack you are going to use for the programmed
gauge has enough power capacities for desired operation.

For information about power consumption at different sampling rate with


different battery pack and operation temperature, please see Appendix D:
Power Consumption Calculation for details.

Page 8
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

(3) Saving the Program file for future use (Fig. 6)

Click on Save To File, save the file to a convenient location on your drive (by default the file
would be saved in your current well file, so change it to a different folder if you want to
keep all program files in one place), naming the file as per the naming convention
established for the location (ex. ABC Oil and Gas Program-Sampling rate-1). This will allow
you to save time in programming the next tool as you will not be required to fill in all the
fields, as it is saved for future use.

Fig. 6

(4) Programming more gauges (Fig. 7)

Connect another gauge and select: Read Program File. Open the file you just saved and click
Program the Tool

Fig. 7

For more information about programming, please refer to SmartView User Manual.

Page 9
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.5 Activating and Testing Battery Packs

To activate and test a battery pack:

Using a PPS Battery Tester to activate the battery pack (Fig. 8)


 Plug-in the battery, the battery’s LED will turn on
 Press the black button about 15 sec and release
 If the battery voltage is lower than 3.2V (or 2.6V for dual cell pack), repeat previous step

A battery pack MUST be reactivated before installation:


 The voltage of battery pack (single cell) should not be lower than 3.2V
 For dual cell battery packs, the voltage should not be lower than 2.6V

Fig. 8

Do NOT reuse 180°C battery packs because they may not be re-depassivated.

Page 10
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.6 Installing Battery Pack

All battery packs are supplied by PPS in various configurations for different temperature
requirements. Typical battery packs are with maximum working temperatures of 85°C、150°C、
165°C and 180°C respectively.

Please see Appendix C: Battery Packs for details.

To install a battery pack:

(1) Remove the battery housing from the gauge.


(2) Connect the battery pack to the gauge. The battery pack has only one way of alignment with
the gauge connector so as to minimize potential damage. Align the lug on the battery pack
with the slot on the gauge connector.

You may consider installing batteries in both gauges (one set) at the
same time, as you need to try and to initiate both gauges at once (this
process will avoid the process of synchronizing the files when they are
retrieved from the tools), and then write down the date and time the
batteries were plugged to the gauges into the Gauges Control Sheet.

(3) Watch the LED on the battery pack after the connection is made. The LED will flash 16 times
indicating that the gauge has been initialized to start working (Fig. 9)

(4) Document all information for each well in Gauge Control Sheet. The exact date and time
when the batteries were connected to each gauge must be documented.

Fig. 9

It may take a few seconds (1-3 seconds) for the LED on the battery
pack to start flashing after the battery pack is inserted into the gauge.

Page 11
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.7 Assembling Battery Housing

Before assembling battery housing with the gauge, please check:


 If the metal C-ring (if available) needs to be replaced;
 If the o-rings and backup rings on the gauge need to be replaced;
 If the battery housing is in good condition.

Do NOT use any pipe wrenches.

For more information about replacing o-rings and backup rings, cleaning pressure
sensor protectors, check battery housings; please see “5.1 Field Maintenance” for
details.

To install battery housing:

(1) Check the metal C-ring (if available);


(2) Apply grease on the O-rings;
(3) Apply anti-seize compound on the threads for high temperature applications;
(4) Once completed, close the battery housing on each tool;
(5) Using a torque wrench and an open-end wrench assemble the battery housing with the
gauge (Fig 10).

For 1.25” OD and 1.27” OD gauges, torque all connections to 90ft-lb

For 0.75” OD gauges, torque all connections to 60ft-lb

(6) Using a torque wrench and an open-end wrench to assemble the bullnose or crossover with
the gauge.

The size of wrenches is dependent on OD size of the PPS25 gauge that you are
assembling. For information about wrench size, please see “Appendix B: Gauge
and Accessories” for details.

Fig. 10

Now, your gauge is ready for an operation!

Page 12
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.8 Important Application Notes

If a gauge is powered by a 180°C battery pack and the ambient temperature is


lower than 20°C, the battery pack shall NOT stay at low temperature. Get the
gauge to downhole ASAP.

If there is vibration and/or shock during downhole operations, centralizers


and/or shock absorbers are recommended to use to protect the gauges.

For high gas concentrations (>10%) of CO2 or H2S applications, bombwell


carriers are recommended to use to protect the gauges. If required to place the
gauges into the gauge carrier (bombwell) using the carrier springs bellow and
above the gauges, torque the gauge carrier connections at 90 ft-lb (122 Nm).

Page 13
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

4.9 Downloading Data

4.9.1 Using the same Gauge Control Sheet that was used when running the gauges, record the
exact date and time at which the gauges were pulled from the nipple, as well as the time the
batteries were released from each gauge (the time the batteries were released will help you
either verify if the time they were plugged into the gauges was recorded correctly or to
calculate this time if it was not recorded initially).

4.9.2 Once the gauges have been retrieved from the well, un-tight all connections.

Use the correct size of wrenches as any other bigger sizes could damage
the gauge’s hex profile.

Do NOT use any pipe wrenches.

4.9.3 Open the battery housing of both recorders, and try to disconnect both batteries in the same
time from both tools (this will help you either check the time the batteries were plugged. Write
it down on the Gauge control Sheet form).

Do NOT twist the battery pack when you disconnect it. Some battery
packs have a plug with push-pull self-latching system, please pull back
the locking ring of the plug by the special tool and then disconnect the
battery pack (Fig.11).

Fig. 11

4.9.4 Open the PPS SmartView software, connect the PPS USB interface to the computer and the
first gauge and click Connect New Tool (Fig. 12).

Fig. 12

4.9.5 Once the gauge is connected by the software, click Download to download record job files
you desired.

For more information about data downloading and processing, please


refer to SmartView User Manual.

Page 14
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

5. Maintenance
The PPS25 gauges must be well maintained in order to ensure successful operations. There are two
levels of maintenance should be implemented:

 Field maintenance
 Manufacturer’s maintenance

5.1 Field Maintenance

Before each operation, please inspect all gauges.

The following regular maintenance should be implemented before each operation:

 Replace the exposed o-rings to protect the gauges from potential damage
caused by the o-ring failure;
 Check functionality of the gauges before putting them into well. You can run
a bench test to check if the gauges are in good condition. Or, use the
Diagnostics function by SmartView software to check your gauges (See 4.3).
 Check voltage of battery packs by a PPS battery tester (See 4.5).

The lowest required voltage of single cell battery pack is 3.2V; for dual
cells battery packs, the lowest voltage of battery is 2.6V.

 Clean the threads and check for any damage;


 Clean the sensor protector.

All threads should be greased after each operation.

5.1.1 Replacing o-rings (Fig. 13)

 Apply o-ring grease;


 Clean o-ring groove and attach a plastic tube to protect the thread;
 As shown in the figure below, use 2 wires to install the o-ring. Ensure the
wires used for this purpose should not damage the o-rings);
 Apply o-ring grease to cover the o-rings.

For information about O-rings, please see 5.1.3 for details.

Fig. 13

Page 15
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

5.1.2 O-rings Location (Fig. 14)

 PPS25 (0.75”)
O-ring 014 × 2

 PPS25 (1.25”)
O-ring 212 × 2

 PPS25-XM (1.27”) O-ring 119 ×2

C-ring

O-ring 119

Fig. 14

Page 16
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

5.1.3 O-Rings Choices under different conditions

H2S or CO2 Pressure Temperature


O-ring #1 O-ring #2 Bomb Well
(%) (kpsi) (°C)
≤2 < 20 < 177 Viton 90 Aflas 90 Not Necessary
2 – 10 < 20 < 177 Chemraz Chemraz Not Necessary
> 10 < 20 < 177 Chemraz Chemraz Necessary

5.1.4 Cleaning the front of pressure sensor

Under normal circumstances, the pressure sensor does not need special maintenance.
But the diaphragm of pressure sensor has attached with some sludge or oil mud after
finished a downhole operation, the front of pressure sensor needs to be clean properly.

 Remove the protector of pressure sensor from the gauge;


 Put the front part of gauge into warm water or solvent (Aqueous cleaners )
for 10mins, and then use a small soft brush to clean the diaphragm of
pressure sensor;
 Use a clean, soft cloth or toilet paper gently wipe.

Do NOT use any hard objects (for example: figure, screwdriver) to


touch the diaphragm of pressure sensor– it will result in pressure
reading draft even damage of pressure sensor.

5.1.5 Installing and removing the protector of pressure sensor (Fig. 15)

 Prepare a protector by filling with o-ring grease;


 Put the protector on gauge pressure sub;
 Use a protector installer-remover to screw the protector.

 To remove the protector, use a protector installer-remover to loose the protector.

Fig. 15

Page 17
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

5.1.6 Checking battery housing (Fig. 16)

Check the battery housing bore if its surface is scratched and uneven.

Fig. 16

Page 18
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

5.2 Manufacturer’s Maintenance

The manufacturer’s maintenance is implemented at PPS manufacturing facility or the authorized


representative locations. The following maintenance services are performed:

 Full function test


 Failed components and parts replacement
 Calibration and verification
 Failure analysis

It is recommended that PPS25 gauges should be recalibrated at least once a


year to keep its normal operating condition and performance.

Page 19
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

6. Troubleshooting

Symptoms Possible problems Solutions


Battery was not installed correctly. Unplug the battery and plug it back in
again.
LED does not flash after the Battery has not been activated. Activate the battery
battery is installed Battery has not enough power. Change the battery.
Memory is Full. Erase the memory.
Gauge is defective. Return the gauge for check and repair.
Gauge is not properly connected to Make sure the gauge is connected
the computer. according to the instructions. Refer to
Software Manual for more
information.
SmartView software doesn’t COM port is locked. Reboot computer and restart the
detect the gauge, or software.
the gauge was detected, but Software or drivers are corrupt or Upgrade to latest software version or
it stopped communicating damaged reinstall (ensure USB devices
disconnected).
Interface box is defective. Use another interface box.
Gauge is defective. (Try connecting Return the gauge for check and repair.
to another gauge to confirm)
Data recorded to memory is Low voltage of the battery Check the battery voltage or change
noisy the battery.
The gauge may need to be Use the Diagnostics function to check
Data is out of the gauge recalibrated if the gauge is sending the correct
specification data, verify with the calibration
records.
Record files are corrupt Use the “DUMP” function to dump
Could not download job
memory of the gauge and then send to
files
PPS for data retrieving.

For more information, please contact PPS for supports. Thank You!

Pioneer Petrotech Services Inc.


#1, 1431 - 40th Ave. N.E.
Calgary, Alberta, Canada T2E 8N6
Phone: 1-403-282-7669
Fax: 1-403-282-0509
Total Free in Canada & USA: 1-888-PP-GAUGE (774-2843)
E-mail: sales@pioneerps.com
Website: www.pioneerps.com

Page 20
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

Appendix A: Specifications

PPS25
Sensor Type Silicon-Sapphire
Pressure Range Up to 20000psi
Pressure Accuracy ±0.03% FS
Pressure Resolution 0.0003% FS
Pressure Drift <3psi/Year
Temperature Rating 125°C (257°F), 150°C (301°F), 177°C (351°F)
Temperature Accuracy ±0.5°C
Temperature Resolution 0.01°C
Power Source Single AA, dual AA or C, CC size Lithium battery pack
Communications USB/RS232
Data Set Contents Time/Pressure/Temperature
Memory capacity 2 million datasets
Outside Diameter 0.75” (19.1mm), 1.25”(31.75mm)
Overall Length 9.8” (248mm) – 0.75” gauge with AA battery housing
12” (305mm) – 0.75” gauge with dual AA battery housing
10.8” (274mm) – 1.25” gauge with C battery housing
12.1(307mm) – 1.25” gauge with CC battery housing
Work Mode MRO
Housing Material Inconel 718 / SS17-4
Service H2S service
Sampling Rate 1s – 18hrs/per sample

PPS25-XM
Sensor Type Silicon-Sapphire
Pressure Range Up to 15000psi (1.27”OD), 20000psi (1.375” OD)
Pressure Accuracy ±0.03% FS
Pressure Resolution 0.0003% FS
Pressure Drift <3psi/Year
Temperature Rating 150°C (301°F), 177°C (351°F)
Temperature Accuracy ±0.5°C
Temperature Resolution 0.01°C
Power Source C or CC size Lithium battery pack (6-pin connector with locker)
Communications USB/RS232
Data Set Contents Time/Pressure/Temperature
Memory capacity 2 million datasets
Outside Diameter 1.27”(32.3mm), 1.375”(35mm)
Overall Length 11.6”(295mm) – 1.27” gauge with C battery pack
13.8”(350mm) – 1.27” gauge with CC battery pack
11.6”(295mm) – 1.375” gauge with C battery pack
14.0”(355mm) – 1.375” gauge with CC battery pack
Work Mode MRO
Housing Material Inconel 718
Service H2S service
Sampling Rate 1s – 18hrs/per sample

Note: The description and specification are subject to change without notice

Page 21
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

Appendix B: Gauge and Accessories


PPS25 1.25” Gauge (one set)

Item Part Name Description P/N QTY.


1 Gauge PPS25 10K/150C, 1.25” SS17-4 09-25-0013-B1 2
2 Battery Housing PPS25 C size battery housing, 1.25” SS17-4 33-25-0010-A 2
3 Bull Nose PPS25 bull nose, 1.25” SS17-4 33-25-0011-A 1
4 Crossover PPS25 crossover, 1.25” SS17-4 33-25-0012-A 1
Aflas 90, 212 – 20pcs; Viton90, 212 – 20pcs
5 Maintenance Kit 01-AC-0071-A1 1
O-ring grease (177C) - 1pc, sensor protector remover – 1pc
6 Battery tester PPS battery tester (4PIN/6PIN) 01-AC-0062-A1 1
7 USB cable PPS USB download cable (4PIN/6PIN) 01-AC-0050-A2 1
8 Software CD PPS SmartView Software and PPS25 User Manual 01-AC-1164-A 1
9 Case 1400 Black case (2×PPS25 1.25” gauges) 01-AC-1478-A 1

Options
1 Gauge PPS25 1.5K/125C, 1.25” SS17-4 09-25-0010-E1
2 Gauge PPS25 3K/125C, 1.25” SS17-4 09-25-0011-E1
3 Gauge PPS25 6K/150C, 1.25” SS17-4 09-25-0012-B1
4 Gauge PPS25 10K/150C, 1.25” SS17-4 09-25-0013-B1
5 Gauge PPS25 15K/150C, 1.25” SS17-4 09-25-0014-B1
6 Gauge PPS25 6K/177C, 1.25” SS17-4 09-25-0012-E1
7 Gauge PPS25 10K/177C, 1.25” SS17-4 09-25-0013-E1
8 Gauge PPS25 15K/177C, 1.25” SS17-4 09-25-0014-E1

9 Gauge PPS25 1.5K/125C, 1.25” Inconel 718 09-25-0010-C1


10 Gauge PPS25 3K/125C, 1.25” Inconel 718 09-25-0011-C1
11 Gauge PPS25 6K/150C, 1.25” Inconel 718 09-25-0012-A1
12 Gauge PPS25 10K/150C, 1.25” Inconel 718 09-25-0013-A1
13 Gauge PPS25 15K/150C, 1.25” Inconel 718 09-25-0014-A1
14 Gauge PPS25 6K/177C, 1.25” Inconel 718 09-25-0012-C1
15 Gauge PPS25 10K/177C, 1.25” Inconel 718 09-25-0013-C1
16 Gauge PPS25 15K/177C, 1.25” Inconel 718 09-25-0014-C1
17 Gauge PPS25 20K/177C, 1.25” Inconel 718 09-25-0015-C1

18 Battery Housing PPS25, 1.25" Inconel 718, C size battery (20kpsi) 33-25-0005-A
19 Battery Housing PPS25, 1.25" Inconel 718, CC size battery (20kpsi) 33-25-0008-A
20 Battery Housing PPS25, 1.25" SS17-4, C size battery (15kpsi) 33-25-0010-A
21 Battery Housing PPS25, 1.25" SS17-4, CC size battery (15kpsi) 33-25-0013-A

22 Bull Nose PPS25 bull nose, 1.25” Inconel 718 33-25-0006-A


23 Crossover PPS25 crossover, 1.25” Inconel 718 33-25-0007-A
24 Bull Nose PPS25 bull nose, 1.25” SS17-4 33-25-0011-A
25 Crossover PPS25 crossover, 1.25” SS17-4 33-25-0012-A

26 Sensor Protector Sensor protector for PPS25 1.25” gauge 33-25-0079-A


27 Protector Remover Protector remover for PPS25 1.25” gauge 01-AC-0069-A1
28 Oil Trap 1.25” Oil Trap - 1.11Stub ACME Pin & ¼” NPT Box, IN718 33-31-1060-A
29 Oil Trap 1.25” Oil Trap - 1.11Stub ACME Pin & ¼” NPT Box, SS17-4 33-31-1060-B

30 O-ring Viton90, 212 01-AC-0064-A2


31 O-ring Aflas 90, 212 01-AC-0065-A1
32 O-ring Chemraz 526, 212 01-AC-0066-A1
33 O-ring Grease Grease (177°C, 150g/5.3oz) 01-AC-0067-A1
34 Anti-seize compound Anti-seize compound (800°C, 20g/0.7oz) 01-AC-0068-A1

Page 22
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

PPS25 0.75” Gauge (one set)

Item Part Name Description P/N QTY.


1 Gauge PPS25 10K/150C, 0.75” SS17-4 09-25-0013-B4 2
2 Battery Housing PPS25 AA size battery housing, 0.75” SS17-4 33-25-0020-A 2
3 Bull Nose PPS25 bull nose, 0.75” SS17-4 33-25-0022-A 1
4 Crossover PPS25 crossover, 0.75” SS17-4 33-25-0023-A 1
Aflas 90, 014 – 20pcs; Viton90, 014 – 20pcs
5 Maintenance Kit 01-AC-0071-A2 1
O-ring grease (177C)- 1pc , sensor protector remover-1pc
6 Battery tester PPS battery tester (4PIN/6PIN) 01-AC-0062-A1 1
7 USB cable PPS USB download cable (4PIN/6PIN) 01-AC-0050-A2 1
8 Software CD PPS SmartView Software and PPS25 User Manual 01-AC-1164-A 1
9 Case 1400 Black case (2×PPS25 0.75” gauges) 01-AC-1478-A 1

Options
1 Gauge PPS25 1.5K/125C, 0.75” SS17-4 09-25-0010-E4
2 Gauge PPS25 3K/125C, 0.75” SS17-4 09-25-0011-E4
3 Gauge PPS25 6K/150C, 0.75” SS17-4 09-25-0012-B4
4 Gauge PPS25 10K/150C, 0.75” SS17-4 09-25-0013-B4
5 Gauge PPS25 15K/150C, 0.75” SS17-4 09-25-0014-B4
6 Gauge PPS25 6K/177C, 0.75” SS17-4 09-25-0012-E4
7 Gauge PPS25 10K/177C, 0.75” SS17-4 09-25-0013-E4
8 Gauge PPS25 15K/177C, 0.75” SS17-4 09-25-0014-E4

9 Gauge PPS25 1.5K/125C, 0.75” Inconel 718 09-25-0010-C4


10 Gauge PPS25 3K/125C, 0.75” Inconel 718 09-25-0011-C4
11 Gauge PPS25 6K/150C, 0.75” Inconel 718 09-25-0012-A4
12 Gauge PPS25 10K/150C, 0.75” Inconel 718 09-25-0013-A4
13 Gauge PPS25 15K/150C, 0.75” Inconel 718 09-25-0014-A4
14 Gauge PPS25 6K/177C, 0.75” Inconel 718 09-25-0012-C4
15 Gauge PPS25 10K/177C, 0.75” Inconel 718 09-25-0013-C4
16 Gauge PPS25 15K/177C, 0.75” Inconel 718 09-25-0014-C4

17 Battery Housing PPS25, 0.75" Inconel 718, AA size battery (20kpsi) 33-25-0015-A
18 Battery Housing PPS25, 0.75" Inconel 718, 2×AA size battery (20kpsi) 33-25-0019-A
19 Battery Housing PPS25, 0.75" SS17-4, AA size battery (15kpsi) 33-25-0020-A
20 Battery Housing PPS25, 0.75" SS17-4, 2×AA size battery (15kpsi) 33-25-0024-A

21 Bull Nose PPS25 bull nose, 0.75” Inconel 718 33-25-0017-A


22 Crossover PPS25 crossover, 0.75” Inconel 718 33-25-0018-A
23 Bull Nose PPS25 bull nose, 0.75” SS17-4 33-25-0022-A
24 Crossover PPS25 crossover, 0.75” SS17-4 33-25-0023-A

25 Sensor Protector Sensor protector for PPS25 0.75” gauge 33-25-0079-A


26 Protector Remover Protector remover for PPS25 0.75” gauge 01-AC-0069-A1
27 Oil Trap 0.75” Oil Trap - 11/16-20 Pin & ¼” NPT Box, Inconel 718 33-25-0087-B1
28 Oil Trap 0.75” Oil Trap - 11/16-20 Pin & ¼” NPT Box, SS17-4 33-25-0087-B

29 O-ring Viton90, 014 01-AC-0064-A5


30 O-ring Aflas 90, 014 01-AC-0065-A7
31 O-ring Chemraz 526, 014 01-AC-0066-A6
32 O-ring Grease Grease (177°C, 150g/5.3oz) 01-AC-0067-A1
33 Anti-seize compound Anti-seize compound (800°C, 20g/0.7oz) 01-AC-0068-A1

Page 23
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

PPS25-XM 1.27” Gauge (one set)

Item Part Name Description P/N QTY.


1 Gauge PPS25-XM 15K/177C, 1.27” Inconel 718 09-25-0034-A2 2
2 Battery Housing PPS25-XM CC size battery housing, 1.27” Inconel 718 33-28-1039-A3 2
3 Bull nose PPS25-XM bull nose, 1.27” Inconel 718 33-25-0031-B1 1
4 Crossover PPS25-XM crossover, 1.27” Inconel 718 33-25-0030-A 1
O-ring: Aflas 90, 119 – 2pcs; Viton90, 119 – 2pcs;
5 Maintenance Kit 01-AC-0071-A9 2
Peek backup ring 119 – 4pcs; Metal C ring – 1pc
6 O-ring grease Grease (177°C, 150g/5.3oz) 01-AC-0067-A1 1
7 Torque wrench Torque wrench, 20-150ft-Ib, with crowfoot 1-1/16" 01-AC-1035-A 1
8 Battery tester PPS battery tester (4PIN/6PIN) 01-AC-0062-A1 1
9 USB cable PPS USB download cable (4PIN/6PIN) 01-AC-0050-A2 1
10 Software CD PPS SmartView Software and PPS25 User Manual 01-AC-1164-A 1
11 Case 1495 Black case (2×PPS25-XM gauges) 01-AC-1479-B 1

Options
1 Gauge PPS25-XM 6K/150C, 1.27” Inconel 718 09-25-0032-A1
2 Gauge PPS25-XM 10K/150C, 1.27” Inconel 718 09-25-0033-A1
3 Gauge PPS25-XM 15K/150C, 1.27” Inconel 718 09-25-0034-A1
4 Gauge PPS25-XM 6K/177C, 1.27” Inconel 718 09-25-0032-A2
5 Gauge PPS25-XM 10K/177C, 1.27” Inconel 718 09-25-0033-A2
6 Gauge PPS25-XM 15K/177C, 1.27” Inconel 718 09-25-0034-A2

7 Battery Housing PPS25-XM, 1.27" Inconel 718, CC size battery (20kpsi) 33-28-1039-A3
8 Battery Housing PPS25-XM, 1.27" Inconel 718, C size battery (20kpsi) 33-25-0027-C Note 1

9 Bull nose PPS25-XM bull nose, 1.27” Inconel 718 33-25-0031-B1


10 Crossover PPS25-XM crossover, 1.27” Inconel 718 33-25-0030-A

11 C-ring Metal C-ring 01-AC-1034-A


12 O-ring Viton90, 119 01-AC-0064-A1
13 O-ring Aflas 90, 119 01-AC-0065-A5
14 O-ring Chemraz 526, 119 01-AC-0066-A5
15 O-ring grease Grease (177°C, 150g/5.3oz) 01-AC-0067-A1
16 Anti-seize compound Anti-seize compound (800°C, 20g/0.7oz) 01-AC-0068-A1

Note 1: For the 1.27” C size battery housing, please contact PPS for details.

Page 24
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

PPS25-XM 1.375” Gauge (one set)

Item Part Name Description P/N QTY.


1 Gauge PPS25-XM 15K/177C, 1.375” Inconel 718 09-25-0040-A2 2
2 Battery Housing PPS25-XM CC size battery housing, 1. 375” Inconel 718 33-28-1099-A 2
3 Bull nose PPS25-XM bull nose, 1. 375” Inconel 718 33-28-1102-A 1
4 Crossover PPS25-XM crossover, 1. 375” Inconel 718 33-28-1103-A 1
O-ring: Aflas 90, 119 – 2pcs; Viton90, 119 – 2pcs;
5 Maintenance Kit 01-AC-0071-A9 2
Peek backup ring 119 – 4pcs; Metal C ring – 1pc
6 O-ring grease Grease (177°C, 150g/5.3oz) 01-AC-0067-A1 1
7 Torque wrench Torque wrench, 20-150ft-Ib, with crowfoot 1-1/16” 01-AC-1035-A 1
8 Battery tester PPS battery tester (4PIN/6PIN) 01-AC-0062-A1 1
9 USB cable PPS USB download cable (4PIN/6PIN) 01-AC-0050-A2 1
10 Software CD PPS SmartView Software and PPS25 User Manual 01-AC-1164-A 1
11 Case 1495 Black case (2×PPS25-XM gauges) 01-AC-1479-B 1

Options
1 Gauge PPS25-XM 6K/150C, 1. 375” Inconel 718 09-25-0038-A1
2 Gauge PPS25-XM 10K/150C, 1. 375” Inconel 718 09-25-0039-A1
3 Gauge PPS25-XM 15K/150C, 1. 375” Inconel 718 09-25-0040-A1
4 Gauge PPS25-XM 20K/150C, 1. 375” Inconel 718 09-25-0041-A1
5 Gauge PPS25-XM 6K/177C, 1. 375” Inconel 718 09-25-0038-A2
6 Gauge PPS25-XM 10K/177C, 1. 375” Inconel 718 09-25-0039-A2
7 Gauge PPS25-XM 15K/177C, 1. 375” Inconel 718 09-25-0040-A2
8 Gauge PPS25-XM 20K/177C, 1. 375” Inconel 718 09-25-0041-A2

9 Battery Housing PPS25-XM, 1. 375" Inconel 718, CC size battery (20kpsi) 33-28-1099-A
10 Battery Housing PPS25-XM, 1. 375" Inconel 718, C size battery (20kpsi) 33-25-0112-A

11 Bull nose PPS25-XM bull nose, 1. 375” Inconel 718 33-28-1102-A


12 Crossover PPS25-XM crossover, 1. 375” Inconel 718 33-28-1103-A

13 Sensor Protector Sensor protector for PPS25-XM 1.375” gauge 33-25-0110-A

14 C-ring Metal C-ring 01-AC-1034-A


15 O-ring Viton90, 119 01-AC-0064-A1
16 O-ring Aflas 90, 119 01-AC-0065-A5
17 O-ring Chemraz 526, 119 01-AC-0066-A5
18 O-ring grease Grease (177°C, 150g/5.3oz) 01-AC-0067-A1
19 Anti-seize compound Anti-seize compound (800°C, 20g/0.7oz) 01-AC-0068-A1

Page 25
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

Appendix C: Battery Packs


PPS25 Battery Pack (for PPS25 0.75” Gauge)
Item Part Name Capacity (Ah) P/N Connector
1 PPS 85°C single AA size battery pack 2.1 01-AC-0012-A0 4 pin
2 PPS 150°C single AA size battery pack 1.6 01-AC-0013-A0 4 pin
3 PPS 165°C single AA size battery pack 1.4 01-AC-0014-A7 4 pin
4 PPS 180°C single AA size battery pack 1.2 01-AC-0015-A0 4 pin

5 PPS 85°C 2×AA size battery pack 4.2 01-AC-0012-A2 4 pin


6 PPS 150°C 2×AA size battery pack 3.2 01-AC-0013-A1 4 pin
7 PPS 165°C 2×AA size battery pack 2.8 01-AC-0014-A8 4 pin
8 PPS 180°C 2×AA size battery pack 2.4 01-AC-0015-A1 4 pin

PPS25 Battery Pack (for PPS25 1.25” Gauge)


Item Part Name Capacity (Ah) P/N Connector
1 PPS 85°C single C size battery pack 7.2 01-AC-0012-A1 4 pin
2 PPS 150°C single C size battery pack 6.2 01-AC-0013-A5 4 pin
3 PPS 165°C single C size battery pack 6.2 01-AC-0014-A0 4 pin
4 PPS 180°C single C size battery pack 5.0 01-AC-0015-A2 4 pin

5 PPS 150°C single CC size battery pack 15 01-AC-0013-A9 4 pin


6 PPS 165°C single CC size battery pack 14 01-AC-0014-A1 4 pin
7 PPS 180°C single CC size battery pack 11.5 01-AC-0015-A3 4 pin

PPS25-XM Battery Pack (for PPS25 1.27” and PPS25 1.375” Gauge)
Item Part Name Capacity (Ah) P/N Connector
1 PPS 150°C single C size battery pack 6.2 01-AC-0013-C4 6 pin
2 PPS 165°C single C size battery pack 6.2 01-AC-0014-B1 6 pin
3 PPS 180°C single C size battery pack 5.0 01-AC-0015-B1 6 pin

4 PPS 150°C single CC size battery pack 15 01-AC-0013-A4 6 pin


5 PPS 165°C single CC size battery pack 14 01-AC-0014-A5 6 pin
6 PPS 180°C single CC size battery pack 11.5 01-AC-0015-A6 6 pin

Note: For C size battery packs with 1.27” battery housing, please contact PPS for details.

For more information about PPS battery packs, please contact PPS for details.

Page 26
PPS25 Electronic Memory Gauge Pioneer Petrotech Services Inc.
sales@pioneerps.com
User Manual 1-888-PP-GAUGE (774-2843)
www.pioneerps.com

Appendix D: Power Consumption Calculation

PPS software (Battery Calculator) is available now to estimate gauge’s power consumption based on gauge
temperature rating, sampling rates, durations and downhole operating temperature.

For more information about PPS products, please contact PPS for details.

Pioneer Petrotech Services Inc.


#1, 1431 - 40th Ave. N.E.
Calgary, Alberta, Canada T2E 8N6
Phone: 1-403-282-7669
Fax: 1-403-282-0509
Total Free in Canada & USA: 1-888-PP-GAUGE (1-888-774-2843)
E-mail: sales@pioneerps.com
Website: www.pioneerps.com

Page 27