DIMENSIONAMENTO DO SISTEMA DE AR DE PARTIDA

Starting air requirements BV Bureau Veritas

References:
a) BV - Bureau Veritas NR 467- Consolidate- March 2018
Pt C, Ch 1, Sec. 2 / 3.3.1 and Pt C, Ch 1, Sec. 10 /17.17.3.1 and 17.3.2 and 17.3.3

b) MCA Starting air requirements


BV Pt C, Ch 1,Sec 10 / 17.17.3.2

REQUIRED QUANTITY OF START (REF. A)


S= 6 + G (G-1)
WHERE:
S= 6 + G (G-1)
S= required quantity of start of consecutive start (17.3.1) 3
G= quantity of propulsion but need exceed 3. 2

REQUIRED VOLUME OF STARTING AIR RECEIVER

V= (n*q1)/(Pmax.-Pmin.) m3

V= Minimum volume per receiver (m3)


n= Number of starts required = 3
q= Air consumption per start = 200 l/s
T= time per start 5 s
q1= Total air Volume for stating 1 m3
Pmax.= Max. Receiver pressure = 30 bar
Pmin.= Min. Required start pressure = 15 bar

V= 0.20 m3 200.00 Liters

Vtotal= 400.00 Liters 450 lts Para 2 motores

Adotado Vt= 0.45 m3

AIR COMPRESSOR REQUIREMENTS

* Required minimum quantity of air compressor(17.3.2) = 1


Required total capacity of air compressor shall be
sufficient to recharge the required receivers from
armospheric pressure in 1 hour (60 minutes) (17.3.2)

Q= Pcyl x Vsyl/1xT

Q= Req'd. total compressor capacity in (scmm).


Pcyl= Storag pressure (bar) 30 bar
Vcyl= Total req'd. air storage volume ( m3) 0.45 m3
T= Charging time. (minutes) 60 min.

Q= 0.225 m3/min. 13.5 m3/h


7.95 scfm

VOLUME REQUIRED OF AIR SERVICE RECEIVER

Consumidores:

Convés principal AR 1 Cx. De mar aré= 2


Consumo= 12 l/s Consumo= 12
Tempo= 20 s Tempo= 5
Total= 240 L Total= 120

PM áre= 1 Convés principal AV. 1


Consumo= 12 l/s Consumo= 12
Tempo= 20 Tempo= 20
Total= 240 L Total= 240

Apito= 1 Cx. De mar av= 2


Consumo= 3.5 l/s Consumo= 12
Tempo= 14 s Tempo= 5
Total= 49 L Total= 120

Planta de trat.= 1 Ar de serviço 1


Consumo= 5 l/s Consumo= 12
Tempo= 12 s Tempo= 20
Total= 60 L Total= 240

CONSUMO TOTAL= 1309 L


Pressão 8 bar
Volume do Reserv.= 163.625 l
Adotado= 300 l

REQUIRED VOLUME OF STARTING AIR RECEIVER

V= (n*q1)/(Pmax.-Pmin.) m3

V= Minimum volume per receiver (m3)


n= Number of starts required = 1
q= Air consumption per start = l/s
T= time per start s
q1= Total air Volume for stating 2.1 m3
Pmax.= Max. Receiver pressure = 7 bar
Pmin.= Min. Required start pressure = 0 bar

V= 0.30 m3 300.00 Liters 300


SERVICE AIR COMPRESSOR REQUIREMENTS

* Required minimum quantity of air compressor(17.3.2) = 1


Required total capacity of air compressor shall be
sufficient to recharge the required receivers from
armospheric pressure in 1 hour (60 minutes) (17.3.2)

Q= Pcyl x Vsyl/1xT

Q= Req'd. total compressor capacity in (scmm).


Pcyl= Storag pressure (bar) 8 bar
Vcyl= Total req'd. air storage volume ( m3) 0.3 m3
T= Charging time. (minutes) 5 min.

Q= 0.48 m3/min. 28.8 m3/h


l/s
s
L

l/s
s
L

l/s
s
L

l/s
s
L