DESIGN
DESIGN OFOF
MBUHQB UNDERGROUND
– SECOND FLOOR
IRRIGATION
CHILLED WATERTANK
PIPE SUPPORT – ETS ROOM
DOCUMENT NUMBER:
MRO-AFG-MBU-STR-CAL-00102
MRO-AFG-HQB-STR-CAL-00401_00
PROJECT:
Advance Military Maintenance Repair Overhaul Center
LOCATION:
Al Ain, UAE
18-08-2016
Design of Manhole
Required : Design the irrigation tank with pump room. Clear inside dimensions are as shown
Material Properties:
Concrete f'c = 35 MPa
Steel fy = 460 MPa
Calculating pressure values at base: using ko = 0.47 for medium dense sand; weight = 17 kN/m3
Triangular load from soil pressure = 0.47 * 17 * 3= 23.97 kPa/m
rectangular load from surcharge = 0.47 * (2.5 +17*0.80) = 7.567 kPa/m total = 31.53 kPa/m governs!
using ko = 0.34 for very dense sand - compacted condition; weight = 20 kN/m3
Triangular load from soil pressure = 0.34 * 20 * 3 = 20.4 kPa/m
rectangular load from surcharge = 0.34 * (2.5 +20*0.80) = 6.29 kPa/m total = 26.69 kPa/m
Water pressure from water at tank cell = 2.1 * 10 = 21 kPa Consider sanitary coefficient = 1.3
.: Effect of soil governs consider load factor = 1.6
Project: AMMROC Sheet No: 2
Location: Headquarters Building By: CSE
Subject: Design of Underground irrigation Tank Date:
A simplified and conservative approach will be use in the design (Cases 1-3)
PCA Coefficients will be use to determine moments and shear
1. A conservative approach is to design the wall as propped cantilever with the base fixed to get the outer vertical bars, Fig A
2. Positive moment bars from 4 - simply supported edge - Fig B
3. Negative moment bars from fixed edge Fig C
Design of Wall
Case 1
Mu = 1.3*1.6*[23.97 * 3 ^2 /(8)+ 0.1283*7.567*3^2/2] = 65.18 kN-m /m
Vu = 1.6 * (23.97*3/2 + 7.567) = 69.635 kN /m
Case 2 PCA Rectangular concrete tanks 5th Edition
Resultant Stresses shall be taken from the superposition of the triangular soil pressure load (Case 1 and Case 6) and
rectangular surcharge load (Case 6 and 10) for 2 supports condition.
+
Project: AMMROC Sheet No: 3
Location: Headquarters Building By: CSE
Subject: Design of Underground irrigation Tank Date:
b = 4m ; a= 3m
b = 4m ; a= 3m
CASE 1 b = 4m ; a= 3m
CASE 6
b = 4m ; a= 3m
b = 4m ; a= 3m
b = 4m ; a= 3m
CASE 5
CASE 10
from Case 2 & 3: horizontal bar -both face and vertical bar interior face , Mu = 29.61 kN-m/m
ρ reqd. = 0.00197 ρ min. = 0.0030435
2
As = 0.00304 * 240 * 1000 = 730 mm / m use T12 -150 = 753 mm 2 /m
Load on wall
top slab self wt = 0.20 * 25 * 2.6/3= 4.33 kN /m
2700
wt. of wall = 0.25 * 25 * 2.7 = 16.9 kN/m
total load on end wall = 21.2 kN/m each side
Live load:
= 13.95 * 2 / 2.6 + 20 = 30.73 kPa/m
s = 380 ( 280/ 306 ) - 2.5 *50 = 222.712 mm maximum spacing is 200mm therefore SAFE!