Sie sind auf Seite 1von 1

10.

00
7.50 10.00
7.50
7.50
1.50 4.50 3.00 1.00 7.50
1.50 4.50 3.00 1.00
1.50 4.50 3.00 1.00
1.50 4.50 3.00 1.00
1.50

1.50
h

1.50

1.50
g d

WP

s1f s1c
2.50

1.50
f

2.50
c

2.50
b 6
4.00

4.00
e

2.50
5

4.00

4.00
1 3 REF
4

4.00

4.00
s1b
e
1.50

1.50
s1g s1deg

3.50
1.50

1.50
a s1a
s2d-e f f
s1fgh
2.00

2.00
d a b s1f

2.00

2.00
12.50

12.50
11.00

12.50
UP DOWN s2a-b

2.00

11.00
UP DOWN

2.00
11.00

11.00
s1a

2.00
WP
s1a
g
c
2.40

2.50

2.40

2.50
c

2.40

2.40
s3a-b-c e h

1.60
a
s2h-i
s3c-d-e

b
2.60

2.50
d i

2.60

2.50
2.60

2.60
ROOF LINE
ROOF LINE

PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE

4.40 4.60
4.40 4.60
6.15 2.85
6.15 2.85

GROUND FLOOR PLAN SECOND FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN
GROUND & SECOND FLOOR LIGHTING LAY-OUT
SCALE 1:100 M.
GROUND & SECOND FLOOR POWER LAY-OUT
SCALE 1:100 M.

NOTES AND SPECIFICATIONS :


N SERVICE
ENTRANCE
2-14 mm²THW WIRE - ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE RULE AND

SCHEDULE OF LOADS
SITE W E
KILOWATT HOUR SERVICE
METER
M 1-8.0 mm² TW WIRE
IN 32 mmØ RSC
REGULATIONS OF THE NATIONAL ELECTRICAL CODE.

LOADINGS SWITCHES SIZES PHASE -2


S
LEGENDS: - ALL MATERIALS TO BE USE SHALL BE NEW AND APPROVED FOR THE LOCATION
CIRCUIT NO. WATTS AMP. VOLTS
PHASE -2A
LIGHTS C.O OTHERS S1 S2 S3 BREAKERS WIRES CONDUITS 60 amp.
MARYLAND ST
1 7 700 3.18 220 2 1 1 20 amp.²
2-3.5 mm. THW CU
+1-2.0 mm² THW in 15 mm
Ø C.
15mm.Ø PVC-CONDUIT
L.O 20 amp. 20 amp. L.O LIGHTING OUTLET - THERE SHALL BE ONE SERVICE DROP FROM THE SOURCE
2-3.5 mm. THW CU
2 8 800 3.64 220 2 1 1 20 amp.² +1-2.0 mm² THW in 15 mm
Ø C.
15mm.Ø PVC-CONDUIT
1 2 CONVENIENCE OUTLET
900 4.09 220 20 amp.²
2-3.5 mm. THW CU
+1-2.0 mm² THW in 15 mm 15mm.Ø PVC-CONDUIT
- MINIMUM SIZE OF CONDUCTOR SHALL BE TYPE TW
3 9 5 1 Ø C.
2-3.5 mm. THW CU
L.O C.O REF REFRIGERATOR OUTLET
4 8 1,440 6.55 220 20 amp.² +1-2.0 mm² THW in 15 mm 15mm.Ø PVC-CONDUIT 20 amp. 20 amp.
Ø C. WP WEATHER PROOF OUTLET - WIRING INSTALLATION SHALL BE CONCEALED FROM VIEW BY INSTALLING
1 REF 1,500 6.82 220 20 amp.²
2-3.5 mm. THW CU
+1-2.0 mm² THW in 15 mm 3 4
5 Ø C.
2-3.5 mm. THW CU
15mm.Ø PVC-CONDUIT
PANEL BOARD CONDUCTOR IN PVC OR EMT CONDUIT EMBEDDED IN CONCRETE AND MASONRY
6 8 1,440 6.55 220 20 amp.² +1-2.0 mm² THW in 15 mm 15mm.Ø PVC-CONDUIT C.O 20 amp. 20 amp. WALL AND OPEN WIRING ABOVE DROP
Ø C. C.O (REF) S

SPARE
2-3.5 mm. THW CU
EL PUERTO REAL SUBDIVIS
ION GATE SWITCH
7 6.82 220 20 amp.² +1-2.0 mm² THW in 15 mm
1,500
Ø C.
15mm.Ø PVC-CONDUIT
5 6
SPARE
2-3.5 mm. THW CU CIRCUIT RUN IN WALL - ALL ELECTRIC INSTALLATION SHALL BE UNDER THE IMMEDIATE SUPERVISION OF
8 1,500 6.82 220 20 amp.² +1-2.0 mm² THW in 15 mm 15mm.Ø PVC-CONDUIT
Ø C.

TOTAL 24 17 9,780 44.47 9 3 2


2-22.0 mm. THW CU
+1-2.0 mm² THW in 15
mm Ø C.
2-14 mm²THW WIRE
1-8.0 mm² TW WIRE
IN 32 mmØ RSC
SPARE 20 amp. 20 amp. SPARE CIRCUIT RUN IN CEILING DULY LICENSED ELECTRICAL ENGINEER.

ROAD
ANALYN DRIVE
7 8 SWITCH LINE

NATIONAL CIRCUIT HOMERUN MOUNTING HIEGHTS:


M KILOWATT HOUR SERVICE METER - CONVENIENCE OUTLET: 300mm. FROM FLOOR LEVEL
VICINITY MAP GROUND
NOT TO SCALE
- LIGHTING OUTLET: CEILING LEVEL
SINGLE LINE DIAGRAM
- SWITCHES: 1500mm. FROM FLOOR LEVEL

ELECTRICAL ENGINEER: PROJECT TITLE / LOCATION: OWNER: SHEET CONTENT: REVISION: SHEET NO:
REG. NO.

PTR NO. PROPOSED TWO (2) STOREY RESIDENTIAL AS SHOWN E


MR.&MRS. ALBERTO JONATHAN G. ZARASPE
DATE: BUILDING 01
PLACE: LOT 22, BLOCK 11,MARYLAND ST.,EL PUERTO REAL CHECKED BY: CADD: DATE:
SUBDIVISION,ALANGILAN,BATANGAS CITY DATE: 8 10
TIN NO: DGT14 SHEET OF