GB012 - 25K
TT/RH-PRM-M21_2018/04 En_Demir
Content
Content
2 Service Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Display Symbols . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Service Function . . . . . . . . . . . . . . . . . . . . . . 4
2.3 Service Function Overview . . . . . . . . . . . . . . 5
2.3.1 1. Service Level . . . . . . . . . . . . . . . . . . . . . . . 5
2.3.2 2. Service Level . . . . . . . . . . . . . . . . . . . . . . . 6
3 Failures / Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Elimination of errrors . . . . . . . . . . . . . . . . . . . 7
3.2 Failure / Error Codes Overview . . . . . . . . . . . 8
3.3 Failure codes and corrections steps . . . . . . . 9
3.4 Sensor (NTC) Values . . . . . . . . . . . . . . . . . . 25
3.4.1 Flow Temperature Sensor . . . . . . . . . . . . . . 25
3.4.2 Domestic Hot Water Temperature Sensor . . 25
3.4.3 Flue Gas Safety Temperature Sensor (Behind
Burner) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.5 Electrical Datas . . . . . . . . . . . . . . . . . . . . . . 26
3.6 Electrical Circuit Diagram . . . . . . . . . . . . . . . 27
3.7 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.8 Function Diagram . . . . . . . . . . . . . . . . . . . . . 31
4 Gas Values (Cental heating and domestic
hot water circuit) 32
2 GB012 - 25K
Safety precautions and symbols 1
GB012 - 25K 3
2 Service Functions
2 Service Functions
2.1 Display Symbols 2.2 Service Function
Service functions are in divided in 2 level :
Symbol Description
• 1. Level (see page 5)
Save a parameter in service • 2. Level (see page 6)
mode
1 2
Air bleeding function is active
(service function : 1.2.C)
2
MAP (fan speed) (service func- 1 3
tion : 2.b.d).
0 bar 4
mode
5 4 3
Domestic hot water circuit is 6 720 643 530-26.1O
active. Fig. 1
1 Stand by (On/off) Button
2 „Up (+)“ Button
Key lock is active. 3 „Down (-)“ Button
4 Temparature Display (°C)
5 Mode Button
Summer mode.
Tab. 1
4 GB012 - 25K
Service Functions 2
B Press mode, “+” and “-” button for 5 second. The service B Press mode button until [ ] symbol will be shown on
function will be shown on Display (e.g. 1.2.C). Display.
B Select the desired/requested service code with “+” or “-” Exit from Service Level :
button. B For the exit from service level press the mode, “+” and “-”
B Press mode button again (for entering). button for 5 second or Stand by button.
After that you will see the selected (default) value on The flow temperature will be shown again on display.
Display.
1. Level
Initial (Factory
Service Code Description Range setting)
1.2.C Automatical Air Purging (0 = offý, 1= active ) Total time : 2 min. 0-1 0
and 20 sec on/off intervall
GB012 - 25K 5
2 Service Functions
2. Level
Service
Code Description Range Initial (Factory Setting)
2.1.b DHW max. heat output (in winter mode) 30 - 100 % 100 %
2.3.F Delay time after DHW in winter mode (Heating mode is disabled for this 0 - 5 min. 1 min.
period of time)
2.9.E Delay time for the turbine ( each unit = 0,5 sec.) 1-6 2
2.b.d Selection of flue length (MAP Value) (0 = off, 1 - 10 : fan speed accord- 0 - 10 0
ing flue pipe length, see flue manuel for details)
6 GB012 - 25K
Service Functions 2
3. Level
Service
Code Description Range Initial (Factory Setting)
GB012 - 25K 7
3 Failures / Errors
3 Failures / Errors
3.1 Elimination of errrors
DANGER: Explosion !
B Turn off gas cock before working on
gasbearing components.
B Check for leaks before working on
gasbearing components.
DANGER: Poisoning !
B Check for leaks before working on
gasbearing components.
8 GB012 - 25K
Failures / Errors 3
MAP not selected (Fan speed adjustment Check the adjustment /selection via service func-
according the flue pipe length). tion 2.b.d).
1H Combustion chamber NTC failure (behind Check the and the heat exchanger surface,
burner) : when the temperature by CC NTC whether is blocked or not. And check the sensor
reached to limit and the connections.
1P Combustion chamber NTC failure (behind burner) Check the and the heat exchanger surface,
1) : whether is blocked or not. And check the sensor
- when NTC not detected or open circuit and the connections.
2P Gradient limit : Temperature rises too rapidly Check the pump, system pressure and by-pass
in heating mode. circuit.
3C Fan speed can not reached to target speed. Check the fan for the blockage and the electrical
supply.
4C Overheat lock-out by temperatur limiters Check the system presseure, temperature sensor,
(STBs) (Flue gas + prim. Heatexchanger). In pump and fuses on board. Discharge the air in
this case ; Heat demands is blocked and system. Check also the flue gas pipe and heatex-
pump stops 3 min. later. changer.
4Y Flow temperature sensor failure (pump is run- Check the flow temperature sensor and the con-
ning). nection.
6A Ignition lock-out (flame not detected) (pump is Check the gas cock, gas pressure, electrode and
running). the cable connection.
6C Safety valve leaks. Check the gas valve, the cable connection and
electrode set.
B3 --> d5 Short circuit / failure in water level switch. Check the condensate water drain and recuperator
2) (condens-heatexchanger).
CL Domestic hot water temperature sensor not Check the sensor and cable connection.
correct installed or failure.
d7 Modulator coil failure (regulator valve on gas Check the cable connection.
valve)
H6 to detect flue gas or fresh air blockages via ionization - Check the entire flue system for any blockage/
3) current (see SI A-01-18-003-01-BCD). recirculation on flue gas side or freshair side
- Check the electrodes and their position / angle
- Check the fan speed adjustment according to flue
gas pipe length (service function 2.bd)
- Check the minimum burner pressure
- Check the primary heat exchanger for any block-
age
- Check if air exists inside the gas supply line
Tab. 5 Failure codes
1) Failure codes is adapted to the EMS (>FD660)
2) Failure codes is adapted to the EMS (>FD660)
3) due to implementaiton GasAirRegulation (GAR) (>FD818)
GB012 - 25K 9
3 Failures / Errors
1H is flashing.
Cumbustion chamber temperature sensor 1) is defect, not detected or overheating in cumbustion cham-
ber (pump runs continuously)
no: -->4.
4. Is the correct MAP (fan speed) value no: B Adjust correct MAP value according flue gas pipe
according flue gas pipe length length and diameter. See capitel 7.2.
choosen ?
1H failure still exist ? -->5.
yes: -->5.
yes: -->6.
10 GB012 - 25K
Failures / Errors 3
1H is flashing.
Cumbustion chamber temperature sensor 1) is defect, not detected or overheating in cumbustion cham-
ber (pump runs continuously)
6. Check the burner gas pressure. Are yes: B Correct the gas pressure values. If not possible,
the values OK ? change the gas valve.
1H failure still exist ? -->7.
no: -->7.
GB012 - 25K 11
3 Failures / Errors
1P is flashing.
Combustion chamber NTC failure (behind burner) : when NTC not detected or open circuit
1. Check if combustion chamber NTC dam- yes: B Check the cable connection.
aged or not and the position.
A6 failure still exist ? -->2.
B Switch off the appliance.
no: B Change the NTC.
B Pull the NTC cables out.
B Connect the cable.
B Measure NTC resistance. B Switch on the appliance.
Are the values correct ? (see NTC val-
ues) A6 failure still exist ? -->2.
2. Check if cable damaged or not. yes: B Change the cable harness.
12 GB012 - 25K
Failures / Errors 3
2P is flashing.
A fast temperature increase detected in central heating (CH) (> 2,7 K/sec).
The appliances will be resetet automaticly, if the flow temp. < 40 ºC.
GB012 - 25K 13
3 Failures / Errors
3A is flashing.
no: -->2.
2. Is there any problem at fan sensor yes: B Change the cable and sensor.
and cable ? B Switch on the appliance.
B Switch off the appliance.
3A failure still exist ? -->3.
B Check the sensor and cable.
no: -->3.
14 GB012 - 25K
Failures / Errors 3
3C is flashing.
2. Check the power voltage supply. yes: B Switch off the appliance.
B Inform related persons/company.
Is voltage below 160 V AC ? B Switch on the appliance.
3C failure still exist? -->3.
no: -->3.
GB012 - 25K 15
3 Failures / Errors
4C is flashing.
Overheat lock-out by temperatur limiters (2 x STB : Flue gas + prim. Heatexchanger). In this case ; Heat
demands is blocked and pump stops 3 minutes later.
2. Is the circulation pump blocked ? yes: B Eliminate the blockage (turn the shaft).
If not succesful :
B Switch off the appliance.
B Cut mains supply.
B Drain the water from appliance.
B Change the pump.
B Fill with water and bleed the system again.
B Connect to main supply.
B Switch on the appliance.
B Press RESET button and restart again.
4C failure still exist? -->3.
no: -->3.
3. Check the flue gas pipe line. yes: B Check the flue gas pipe and remove the block-
age.
Is there any blockage ? B Switch on the appliance.
B Cihazý resetleyip yeniden çalýþtýrýn.
4C failure still exist? -->4.
no: -->4.
no: -->5.
16 GB012 - 25K
Failures / Errors 3
4C is flashing.
Overheat lock-out by temperatur limiters (2 x STB : Flue gas + prim. Heatexchanger). In this case ; Heat
demands is blocked and pump stops 3 minutes later.
4Y is flashing.
1. Check if CH flow temperature sensor yes: B Check the connection terminal on NTC.
(NTC) is damaged or not ?
4Y failure still exist ? -->2.
B Switch off the appliance.
B Pull cables out. no: B Change NTC.
B Measure the electrical resistance B Connect the cable.
of the NTC sensor. B Switch on the appliance.
Are the measured values OK ?
4Y failure still exist ? -->2.
(resistance table)
2. Check if the cables are damaged or yes: B Chance the cable harness.
not?. B Switch on the appliance.
B Switch off the appliance.
4Y failure still exist ? -->3.
B ·If NTC changed :
- disassemble the NTC cable from no: -->3.
NTC.
- measure the sensor resistance.
- assemble the NTC to NTC cable
again.
B Pull out the 20 poled (main socket)
connector from the electronic
card.
B Measure the electrical resistance
of NTC on socket. Are the meas-
ured resistance values at at NTC
and socket connection same?
GB012 - 25K 17
3 Failures / Errors
6A is flashing.
no: -->2.
3. Air in the gas pipe line? yes: B Open the gas inlet cock.
B Press RESET button and restart again.
6A failure still exist? -->4.
no: -->4.
4. Ist the thermal gas inlet cock acti- yes: B Change the cock.
vated ? B Press RESET button and restart again.
(if it is installed) 6A failure still exist? -->5.
no: -->5.
5. Natural gas : yes: B Check if the montage of the gas pressure regu-
Is there any gas pressure regulator lator assembly is correct or not ? If necessory
at the house entrance ? correct it.
B M6Asure the gas inlet pressure. If there is a
deviation inform the gas distributor company.
B Press RESET button and restart again.
6A failure still exist? -->6.
no: -->6.
LPG (liquid gas): yes: -->6.
Is there sufficient gas flow in the LPG
no: B Is the tank full enough ?
line to operate appliance ?
B Is there any air in the gas pipe?
B Is the external tank magnet valve tripgered ?
B Is the gas entry pressure OK? ( if too high check
the regulator).
B Press RESET button and restart again.
6A failure still exist?-->6.
18 GB012 - 25K
Failures / Errors 3
6A is flashing.
no: -->9.
11. Check ignition electrode for damage yes: B Switch off the appliance.
and oxidation ? B Change the ignition cable.
B Switch on the appliance.
B Press RESET button and restart again.
6A failure still exist ? -->12.
no: -->12.
GB012 - 25K 19
3 Failures / Errors
6A is flashing.
20 GB012 - 25K
Failures / Errors 3
6C is flashing.
After switching off gas flame detected (even the safety valves are closed (leakege))
GB012 - 25K 21
3 Failures / Errors
B3 / d5 is flashing.
Short circuit / failure in water level switch in recuperator (condens heat exchanger).
no: -->2.
2. Check the water level switch. yes: B Accumulated water in recuperaotr or switch
contacts are wet.
Is the resistance lower 300 kOhm ? B It can be blockage at recuperator drain. Correct
it.
B Is the siphon connection adapter in right posi-
tion. It should be in vertical position.
B Leakage in water level switch ?. If yes, change
it.
B3 / d5 failure still exist? -->3.
22 GB012 - 25K
Failures / Errors 3
CL is flashing.
1. Check the DHW NTC whether it is cor- CL failure still exist ? -->2.
rect installed or not.
2. Check if water NTC damaged or not ?. yes: B Change the cable harnness.
B Switch off the appliance. B Switch on the appliance.
B Pull out NTC cables. CL failure still exist ? -->3.
B Measure resistance of NTC (Ohm).
no: -->4.
Is the NTC resistance value OK ?
4. Check the DHW circuit in main heat B In case of calcification, clean it with special pump.
exchanger whether it is calcified or If necessary change the heat exchanger.
not.
CL failure still exist ? -->5.
GB012 - 25K 23
3 Failures / Errors
d7 is flashing.
Appliance doesn’t modulate / Regulator valve problem (don’t regulate to max. position).
1. Check if the regulator valve cable yes: B Change the cable harness or correct it.
damaged or not and the connection. B Switch on the appliance.
Are the connections wrong?
d7 failure still exist ? -->2.
no: -->2.
2. Check the resistance from regulator yes: B Change the cable harness.
valve. B Switch on the appliance.
B Switch off the appliance.
d7 failure still exist ? -->3.
B Pull out the 20 poled connector on
control unit. no: -->3.
B Measure the resistance.
3. Check the resistance from regulator yes: B Change the gas valve.
valve. B Switch on the appliance.
B Reglaj ventiline gerilim/akým geliyor
d7 failure still exist ? -->4.
mu ?
B Measure the resistance directly on no: -->4.
gas valve.
24 GB012 - 25K
Failures / Errors 3
II is flashing.
MAP not selected (Fan speed adjustment according the flue pipe length)
Attention : The appliance is delivered with MAP value “0” (service function : 2.b.d). In this condition the
appliance doesn’t run. The “I I” symbol will be shown on display alternately.
1. MAP value is according the flue gas yes: B Adjust the MAP value via service fonction 2.b.d.
pipe length not selected. (for details, see flue gas instruction manuel)
I I symbol still exist ? -->2.
no: -->2.
GB012 - 25K 25
3 Failures / Errors
26 GB012 - 25K
Failures / Errors 3
Flow Temp. Sensor 5 VDC 20 ºC => 14,8 kOhm ± 0,5 kOhm see resistance table
(NTC) 60 ºC => 3,2 kOhm
Flue gas safety (Com- 5 VDC 20 ºC => 12,1 kOhm ± 0,5 kOhm ---
bustion chamber ) Sen- 60 ºC => 2,9 kOhm
sor (NTC, behind
burner)
Water Flow Rate Sen- 1 = “-” 0 VDC 9,6 Hz = 1,5 l/dk. ± 2 Hz Can measured in Hz
sor (Turbine) 68,7 Hz = 10 l/dk. ± 6 Hz between 1. and 2.
2 = Signal 0-5 VDC
cable.
3 = “+” 5 VDC
Tab. 9
GB012 - 25K 27
3 Failures / Errors
17
3
16
18
15 4
5
5
14
13
6
12 2
9
10
11
7
6 720 643 530-07.2O
Fig. 2
28 GB012 - 25K
Failures / Errors 3
Legends :
1 Fan
2 Flue gas temperature limiter (STB) (Recuperator)
3 Water level switch
4 Ionisation electrode
5 Pump
6 Turbine
7 LCD Dispaly connection
8 Transformer
9 Controller (room thermostat) connection
10 Diagnostic connection
11 Igniton transformer
12 Supply cable
13 DHW temperature sensor (NTC)
14 Gas valve
15 Ignition electrode
16 Temperatur limiter (STB)
17 Flow temperature sensor
18 Flue gas safety (combustion chamber) sensor
GB012 - 25K 29
3 Failures / Errors
3.7 Structure
1
32
31
2
3
30 4
29
28 5
7 9
8
27
26
25
24
23
12
22
13
14 11 10
21 20 19 18
15
mode
reset
17 16
6 720 643 530-06.1O
Fig. 3
30 GB012 - 25K
Failures / Errors 3
Key to Figures :
1 Expansion vessel
2 Flue gas temperature limiter (STB)
3 Condesing-Heat Exchanger (Recuperator)
4 Water level switch (Condensate backup sensor)
5 Combustion chamber
6 Distribution pipe (Inj. nozzle)
7 Ionisation electrode
8 Safety valve (heating circuit)
9 Autom. air vent valve
10 Circulation pump
11 Pump speed switch
12 Condensate siphon
13 Turbine
14 Condensate water hose
15 Manometer
16 (-) Button
17 Mode Button
18 (+) Button
19 Display
20 Stand-by (On/off) Button
21 Control unit
22 Water filling valve
23 Gas Valve
24 Type lable
25 DHW temperature sensor
26 Ignition electrode
27 Flue gas safety sensor (Combustion chamber sensor)
(behind burner)
28 Flow temperature sensor
29 Temperature limiter for heating block
30 Fan
31 Combustion air inlet
32 Flue gas pipe
GB012 - 25K 31
3 Failures / Errors
Fig. 4
1 Control Unit (Cotronic 3) 21 CH safety valve
2 Water filling valve 22 Siphon
3 By-pass pipe 23 Turbine
4 DHW temperatur sensor 24 DHW water flow rate limiter + Filter
5 Flow temperature sensor 25 Manometer
6 Temperatur limiter 26 Gas valve
7 Combustion chamber (flue gas safety) sensor 27 Siphon (trichtersiphon) (ops.)
8 Ionisation electrode 28 Regulator valve
9 Inj. nozzle 29 Gas filter
10 Burner 30 Measurement point (Inj. pressure)
11 Ignition electrode 31 Measurement point (Gas inlet pressure)
12 Heatexchanger 32 Safety valve
13 Combustion chamber (fresh air) 33 CH-Return circuit
14 Combustion chamber 34 DHW inlet
15 Fan 35 Gas inlet
16 Condensate-Heatexchanger (Recuperator) 36 DHW outlet
17 Flue gas pipe 37 CH- Flow
18 Expansion vessel 38 Manuel air vent valve
19 Autom. air vent valve 40 Flue gas temperature limiter (STB)
20 Circulation pump
32 GB012 - 25K
Gas Values (Cental heating and domestic hot water circuit) 4
GB012 - 25K 33
4
Notes
34 GB012 - 25K