Sie sind auf Seite 1von 4

Double

Benzene
t1 80
t2 140
μ 1.21
Jh 236
k 0.091
D (Inner dia of inner pipe) 0.115
m 9820
Cp 0.425
Q 250410
ID 1.38
OD 1.66
Surface area 0.435
Density 55

Pressure Drop
Inner Pipe
f 0.005693399
P 3.208013195
Double Pipe Heat Exc
Toluene Inner Pipe Calculations
T1 200 Δ t1
T2 100 Δ t2
D1 ( Outer dia of inner pipe ) 0.138 LMTD
D2 ( inner dia of outer pipe ) 0.1725 Area
m 5691.1363636364 MassVelocity
μ 0.99 Renould No
Jh 167 Jh Factor
m 6330 (Cpμ/k)^1/3
Cp 0.44 hi
k 0.085 hio
Rd 0.002
g 418000000
Density 54.3

Pressure Drop
Annulus
Eq Dia 0.0345
Re 26219.0768419706
f 0.0071794645
Fa 22.939040679
V 3.8488515929
Ft 0.6900772632 g
P 8.9101465574
Heat Exchanger
nner Pipe Calculations Annulus Calculations
60 LMTD 52.119481
20 Area 0.0084134
52.1194809929 Eq Diameter 0.077625
0.0103868819 Mass Velocity 752373.51
945423.280931559 Re NO 58992.923
89854.2787662226 Jh Factor 167
236 ho 315.27541
1.7811929575 Uc 147.31633
332.6339126577 Ud 113.79006
276.5269876311 A 42.222821
Req Length 97.063956 120
No of Pins 4.8531978

32.2