CI/SfB
| | | Fg2 | |
December 1999
ARCH SETS
PAGES 1 TO 3
GROUP BD
BONDING BRICKS
PAGE 4
GROUP CP
COPINGS AND CAPPINGS
PAGE 5
TECHNICAL SERVICES
GROUP BN
Our Technical Services Team, headed by the Design Architect,
BULLNOSE BRICKS
offers a free advisory service to customers on all aspects of PAGES 6 TO 9
bricks and brickwork, including:
• Workmanship • Movement
GROUP AN
• Product Characteristics ANGLE AND CANT BRICKS
PAGES 10 TO 13
• Special Shaped Bricks
on request.
PURPOSE-MADE SPECIALS
PAGES 18 TO 21
[i]
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 4
THE FOLLOWING NOTES HAVE BEEN INCLUDED TO ASSIST PLEASE USE THIS CHECKLIST WHEN ORDERING BOTH BRITISH
WHEN SPECIFYING SPECIAL SHAPED BRICKS. STANDARD AND PURPOSE-MADE SPECIAL SHAPED BRICKS.
When exposure to saturation and freezing is anticipated, Include on your order the project name, contractor, full delivery
specials should be chosen which match bricks offering long term address and a site contact if known.
durability and quality.
All Chelwood Brick wirecuts, stocks and Flagship Range BRICK TYPES AND QUANTITIES
handmade bricks are of FL durability; frost resistant and low in Always specify the brick name and the quantities for each type
soluble salt content. of special shape required.
DRAWINGS DESCRIPTIONS
It is particularly helpful if constructional drawings can be British Standard specials: Include the BS reference number and
submitted when discussing details with our Technical Services a full description.
Department. Purpose-made specials: A three dimensional sketch should be
attached to your order illustrating all dimensions and facing
CAD FACILITY requirements. Please ensure that exact requirements on hand-
A dedicated CAD system can provide three-dimensional ed specials are noted.
drawings illustrating individual bricks and details if required.
OTHER REQUIREMENTS
LEFT AND RIGHT HANDING Please include details of any specific requirements, such as any
For certain details it is necessary to consider both left and right dimensional tolerances, perforation patterns, additional fair
hand versions of particular specials. It is also important to faces and direction of texture.
consider handing in relation to directions of texture. Please also
ensure that the correct quantities of each 'hand' are always SCHEDULES
specified. Certain specials are available ex stock, but others are made to
order. To ensure delivery schedules are met, please order early
FAIR FACES and indicate any priority requirements.
Standard fair faces are clearly identified in this manual. Please
advise if additional faces are required. ORDERING
ANGLES, RETURNS AND STOP ENDS Chelwood Brick Ltd, Adswood Road, Cheadle Hulme, Cheadle,
To achieve satisfactory detailing at changes in building plan and Cheshire, SK8 5QY.
also to complement design details, please consider the use of Tel: 0161 485 8211
appropriate specials. These may require additional faces,
Fax: 0161 488 4351
particularly for stop end features. Please liaise with us at an
early stage in the design. Web Site: www.chelwood.co.uk
PURPOSE-MADE SPECIALS
ARCH SETS
[ii]
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 5
α
α
A A
F A F
D D
E E
LH shown LH shown
MS.3.2 (RH)
MS.1.1
MS.34 (LH)
MS.3.1 (LH) MS.1.1 MS.3.3 (RH)
ARCH SET A ARCH SET B ARCH SET C ARCH SET D ARCH SET E
MS.1.1 MS.3.4 MS. MS. MS. MS. MS. MS. MS. MS. MS. MS. MS. MS. MS. MS.
1.1 3.1 3.2 3.3 2.2 6.2 7.2 2.1 6.1 7.1 2.2 3.5 6.3 7.3
No. of Specials 4 2 - 2 2 2 4 2 1 4 2 1 2 2 2 1
460mm
LH - 1 - 1 1 1 2 1 - 2 1 - 1 1 1 -
RH - 1 - 1 1 1 2 1 - 2 1 - 1 1 1 -
TYPICAL OPENINGS
No. of Specials 10 2 6 2 2 2 10 2 1 10 2 1 8 2 2 1
910mm
LH - 1 - 1 1 1 5 1 - 5 1 - 4 1 1 -
RH - 1 - 1 1 1 5 1 - 5 1 - 4 1 1 -
No. of Specials 16 2 12 2 2 2 16 2 1 16 2 1 14 2 2 1
1360mm LH - 1 - 1 1 1 8 1 - 8 1 - 7 1 1 -
RH - 1 - 1 1 1 8 1 - 8 1 - 7 1 1 -
No. of Specials 22 2 18 2 2 2 22 2 1 22 2 1 20 2 2 1
1810mm LH - 1 - 1 1 1 11 1 - 11 1 - 10 1 1 -
RH - 1 - 1 1 1 11 1 - 11 1 - 10 1 1 -
MS.1 A B C D E F
MS.1.1 215 102 65 72 30 100
MS.2 A B C D E F a
MS.2.1 215 102 65 - - - 75°
Indicates standard face matched to brick type.
MS.2.2 215 102 65 72 30 50 75°
Where additional faces are required, please
liaise with our Technical Services Department.
1
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 7
MS.3.1
Transition brick
B C
A MS.3 A B C D E F G H a
MS.3.1 215 102 65 92 10 30 - - -
F
MS.3.2 215 102 65 82 20 35 10 65 -
MS.3.3 215 102 65 72 30 70 20 100 -
MS.6.2 (LH)
MS.3.2 (RH) MS.2.2 (LH)
MS.3.3 (RH) MS.7.2
MS.3.1 (LH)
B C B C C
B
A A A
F F
F G
G H
H
D D D
E E E
LH shown LH shown LH shown
MS.3.5
Transition brick
B C
A
F
Indicates standard face matched to brick type.
Where additional faces are required, please
liaise with our Technical Services Department.
2
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 8
MS.6.1
Springer B C
α
MS.6 A B C D E F G H a
MS.6.1 215 102 81 102 139 - - - 75°
MS.6.2 215 102 81 72 30 50 102 37 75°
A
MS.6.3 215 102 63 102 121 - - - 75°
MS.7 A B C D E F G a
E
MS.7.1 215 102 180 65 - - - 75°
D
MS.7.2 215 102 180 65 72 30 50 75°
LH shown
MS.7.3 215 102 217 102 102 20 33 75°
MS.6.1
(LH) MS.6.3 (LH)
MS.7.3 MS.2.2 (RH)
MS.7.1
MS.3.5 (LH)
MS.2.1 (LH)
α α
F A
A
A
α
G D E D
H E D
LH shown LH shown
MS.7.2 MS.7.3
Keystone Keystone
B B
C C
F
G
A A Indicates standard face matched to brick type.
α G Where additional faces are required, please
α
liaise with our Technical Services Department.
3
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 9
BD.1.1 BD.1.3
Half bat (snap header) Standard brick faced on bed
mirror
B A
BD.1.2
Three quarter bat BD.1.1 A B C
BD.1.1 102 102 65
BD.1.2 A B C
C BD.1.2 159 102 65
C
A A
B B
BD.1.3 A B C
BD.1.3 215 102 65
BD.2 BD.4
BD.3
BD.1.2
BD.1.3
BD.1.1
B mirror BD.3 A B C
A
BD.3 215 46 65
C
BD.4 A B C
BD.4.1 215 159 102
D BD.4.2 215 159 65
E BD.4.3 215 215 102
BD.4.4 215 215 65
LH shown
BD.3
Queen closer
C
C Indicates standard face matched to brick type.
A
Where additional faces are required, please
B liaise with our Technical Services Department.
A B
Please note that special shaped bricks may be
perforated unless specified otherwise.
4
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 10
CP.1.1 CP.1.2
Half round coping Half round capping
mirror mirror
CP.1.1 A B C D1 D2
D2 CP.1.1 305 153 65 13 15
D1 B
B
CP.1.2 A B C
A
A CP.1.2 215 108 65
C
C
CP.1.1
CP.2.1
CP.2.2
CP.1.2
Design Note
Please remember to order specially faced
units for exposed stop-end situations;
standard copings and cappings are not
E faced on end. For angle returns and
E
junctions, please liaise with our Technical
D2
Services Department.
D1
B B
Indicates standard face matched to brick type.
A A Where additional faces are required, please
C liaise with our Technical Services Department.
C
Please note that special shaped bricks may be
perforated unless specified otherwise.
5
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 11
BN.1 BN.2
Single bullnose (left or right hand) Double Bullnose
mirror
A
B
LH shown BN.1 A B C r
BN.1.1 215 102 65 25
BN.3 BN.1.2 215 102 65 51
C
BN.3 A B C D r
A
LH shown B BN.3.1 215 102 65 25 25
D
BN.3.2 215 102 65 25 51
BN.2 BN.1
BN.4 BN.3
BN.6 BN.5
BN.4 A B C D r
BN.4 BN.5 BN.4.1 215 102 65 25 25
Double bullnose stop Single bullnose header on flat BN.4.2 215 102 65 25 51
mirror
BN.5 A B C r
C BN.5.1 215 102 65 25
BN.5.2 215 102 65 51
r
A BN.6 A B C r
B BN.6.1 215 102 65 25
BN.6.2 215 102 65 51
BN.6
Single bullnose stretcher on flat
r D
r
6
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 12
BN.7 BN.9
Single bullnose internal return, Bullnose internal return,
stretcher faced (left or right hand) flat faced (left or right hand)
C r C r r BN.7 A B C r
A A BN.7.1 215 102 65 25
B B BN.7.2 215 102 65 51
LH shown LH shown
BN.7.3 215 102 215 25
BN.7.4 215 102 215 51
BN.8
Single bullnose internal return,
header faced (left or right hand) BN.8 A B C r
BN.8.1 215 102 65 25
BN.8.2 215 102 65 51
BN.8.3 215 102 102 25
r
BN.8.4 215 102 102 51
C r
A BN.9 A B C r
B BN.9.1 215 102 65 25
LH shown BN.9.2 215 102 65 51
BN.9
BN.10
BN.7 BN.8
BN.11
BN.10 A B C r
BN.10 BN.11
BN.10.1 215 65 102 25
Bullnose external return on edge Bullnose external return on flat
BN.10.2 215 65 102 51
(left or right hand) (left or right hand)
BN.10.3 215 215 102 25
mirror mirror BN.10.4 215 215 102 51
BN.11 A B C r
r BN.11.1 215 102 65 25
r
BN.11.2 215 102 65 51
r r BN.11.3 215 215 65 25
BN.11.4 215 215 65 51
7
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 13
mirror
BN.13 A B C r
BN.13
B
Bullnose double header on flat BN.15 A B C r
BN.14
Bullnose double stretcher on flat
BN.12
mirror
BN.13
BN.15
BN.14
C
r
A
B
BN.16
BN.17
BN.15
Stop end to double bullnose on edge
and to bullnose double header on flat
(square corners on bed)
BN.16 A B C r
mirror BN.17 BN.16.1 215 102 65 25
Cownose stop BN.16.2 215 102 65 51
mirror
BN.17 A B C D r
r BN.17.1 215 102 65 25 25
r
C
Indicates standard face matched to brick type.
Where additional faces are required, please
A B A liaise with our Technical Services Department.
D
Please note that special shaped bricks may be
perforated unless specified otherwise.
8
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 14
BN.18 BN.19
Stop end to double bullnose on edge External return to double bullnose on
and to bullnose double header on flat edge and to bullnose double header
(rounded corners on bed) on flat (square corners on bed)
mirror mirror
BN.18 A B C r
BN.18.1 215 159 102 25
BN.18.2 215 159 102 51
BN.18.3 215 215 102 25
r BN.18.4 215 215 102 51
r r
r BN.18.5 215 159 65 25
r r BN.18.6 215 159 65 51
A BN.18.7 215 215 65 25
BN.18.8 215 215 65 51
BN.19 A B C r
BN.19.1 215 215 102 25
C C BN.19.2 215 215 102 51
BN.19.3 215 215 65 25
r
BN.19.4 215 215 65 51
A r B A B
BN.19
BN.18 BN.20
BN.21
BN.21 A B C D r a
BN.21.1 215 102 159 101 25 30°
B
α Indicates standard face matched to brick type.
A B Where additional faces are required, please
r
C C liaise with our Technical Services Department.
9
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 15
AN.1
Squint (left or right hand)
90˚
E
α A
D LH shown
AN.1 A B C D E a
AN.2 AN.1.1 164 102 65 51 89 30°
External angle (left or right hand) AN.1.2 164 102 65 51 94 45°
AN.1.3 164 102 65 51 117 60°
B
C AN.2 A B C D a
AN.2.1 1591 102 65 102 30°
AN.2.2 1591 102 65 102 45°
AN.2.3 1591 102 65 102 60°
A AN.2.4* 2152 102 65 102 30°
α AN.2.5* 2152 102 65 102 45°
AN.3
AN.1
AN.2
AN.3 AN.3 A B C D a
AN.3.1 1642 102 65 51 30°
Internal angle (left or right hand)
AN.3.2 1642 102 65 51 45°
AN.3.3 1642 102 65 51 60°
AN.3.4 1591 102 65 102 30°
AN.3.5 1591 102 65 102 45°
B
AN.3.6 1591 102 65 102 60°
AN.3.7* 2152 102 65 102 30°
C
α AN.3.8* 2152 102 65 102 45°
AN.3.9* 2152 102 65 102 60°
A
D
LH shown
1
suitable for quarter bond without cutting
2
suitable for half bond without cutting
10
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 16
AN.5 AN.7
Single cant (left or right hand) Single cant external return
B mirror
A
C
E AN.5 A B C D E
D
AN.5.1 215 102 65 46 159
LH shown AN.5.2 215 102 65 60 173
E E
AN.6
AN.6 A B C D E
Double cant AN.6.1 215 102 65 46 103
AN.6.2 215 102 65 60 131
mirror
C
D AN.7 A B C D E
AN.7.1 215 215 102 46 159
B A AN.7.2 215 215 102 60 173
AN.8
B
A AN.5
AN.9
C
AN.7
E
D
AN.6
mirror mirror
45˚
AN.9 A B C D E
AN.9.1 215 215 102 46 159
AN.9.2 215 215 102 60 173
E E
E E
C
45˚ C 45˚
11
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 17
AN.10 AN.13
Single cant external angle Double cant stop end
(canted corners on bed)
mirror mirror
135˚
AN.10 A B C D E F a
A AN.10.1 215 102 159 46 159 101 30°
B
AN.10.2 215 102 159 60 173 101 30°
AN.11 AN.14
Single cant internal angle
mirror
AN.12 AN.13
α
AN.11
C C
E B
AN.10
45˚
A
D
F F
mirror mirror
AN.13 A B C D E F
AN.13.1 215 215 102 46 103 159
AN.13.2 215 215 102 60 131 173
AN.14 A B C D E
AN.14.1 215 215 102 46 103
AN.14.2 215 215 102 60 131
F E E E
C
C Indicates standard face matched to brick type.
D D
Where additional faces are required, please
liaise with our Technical Services Department.
12
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 18
AN.15 AN.16
Double cant external return with Double cant external return with
internal mitre (canted corners on bed) internal slope (square corners on bed)
mirror mirror
45˚ 45˚
E E 45˚
E E
AN.15 A B C D E F
AN.15.1 215 215 102 46 103 159
AN.15.2 215 215 102 60 131 173
C
D C
D
F F AN.16 A B C D E
AN.16.1 215 215 102 46 103
A B A B
45˚ AN.16.2 215 215 102 60 131
AN.16
AN.15 AN.17
AN.18
AN.17 AN.18
Double cant external return with Double cant angle
internal slope (canted corners on bed) AN.17 A B C D E F
AN.17.1 215 215 102 46 103 159
mirror mirror
AN.17.2 215 215 102 60 131 173
B
AN.18 A B C D E F a
AN.18.1 215 102 159 46 103 101 30°
45˚
A AN.18.2 215 102 159 60 131 101 30°
AN.18.3 215 102 159 46 103 70 45°
AN.18.4 215 102 159 60 131 70 45°
AN.18.5 215 102 159 46 103 35 60°
F F
AN.18.6 215 102 159 60 131 35 60°
45˚
E E
C
D Indicates standard face matched to brick type.
D
Where additional faces are required, please
F F liaise with our Technical Services Department.
α
Please note that special shaped bricks may be
A B C C perforated unless specified otherwise.
13
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 19
PL.1 PL.2
Plinth stop or Cant stop Plinth header
(left or right hand)
B B
E E
C C
45˚ PL.1 A B C D E F
PL.1.1 215 102 65 9 159 46
D
PL.1.2 215 102 65 23 173 60
F
45˚ A A
PL.2 A B C D E
D
PL.2.1 215 102 65 9 159
LH shown PL.2.2 215 102 65 23 173
PL.5 PL.4
PL.7
PL.2
PL.3
PL.1
E
B PL.4 A B C D E F
45˚
PL.4.1 215 102 65 9 46 169
F
C PL.4.2 215 102 65 23 60 155
D
45˚
PL.5 A B C D E F
C E PL.5.1 215 102 65 9 159 46
A 45˚ A PL.5.2 215 102 65 23 173 60
B D
LH shown
PL.5
Plinth internal return (short)
(left or right hand)
B
Design Note
Designers are recommended to specify
dimension ‘D’ on plinth bricks as 23mm
C
E rather than 9mm when using handmade or
F stock bricks. For alternative plinth coursing,
45˚ A please refer to Chelwood purpose-made
D brick details on page 18.
14
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 20
PL.6
Plinth internal angle (left or right hand)
F
PL.6 A B C D E F a
PL.6.1 1642 102 65 9 51 46 30°
45˚ PL.6.2 1642 102 65 23 51 60 30°
D PL.6.3 1642 102 65 9 51 46 45°
PL.6.4 1642 102 65 23 51 60 45°
α
PL.6.5 1642 102 65 9 51 46 60°
C
PL.6.6 1642 102 65 23 51 60 60°
A PL.6.7 1591 102 65 9 102 46 30°
PL.6.8 1591 102 65 23 102 60 30°
B
E PL.6.9 1591 102 65 9 102 46 45°
LH shown
PL.6.10 1591 102 65 23 102 60 45°
PL.6.11 1591 102 65 9 102 46 60°
PL.7 PL.6.12 1591 102 65 23 102 60 60°
Plinth external return (left or right hand) PL.6.13* 2152 102 65 9 102 46 30°
F
PL.6.14* 2152 102 65 23 102 60 30°
E PL.6.15* 2152 102 65 9 102 46 45°
45˚ PL.6.16* 2152 102 65 23 102 60 45°
PL.6.17* 2152 102 65 9 102 46 60°
PL.6.18* 2152 102 65 23 102 60 60°
D
C
A PL.7 A B C D E F
B PL.7.1 215 102 65 9 159 46
LH shown PL.7.2 215 102 65 23 173 60
PL.6
PL.9
PL.8
PL.8 A B C D E F a
PL.8
PL.8.1 1591 102 65 9 102 46 30°
Plinth external angle
PL.8.2 1591 102 65 23 102 60 30°
(left or right hand)
PL.8.3 1591 102 65 9 102 46 45°
F
PL.8.4 1591 102 65 23 102 60 45°
45˚ PL.8.5 1591 102 65 9 102 46 60°
15
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 21
AR.1 AR.2
Tapered header Tapered stretcher AR.1 A B C D Ideal span
Dimension No. of
No. of bricks. ......
in semi circle
Dimension whole bricks
AR.1.1 215 102 75 59 910 4 20 or 21
mirror
C AR.1.2 215 102 75 64 1360 6 28 or 29
AR.1.3 215 102 75 66 1810 8 36 or 37
D
AR.1.4 215 102 75 69 2710 12 53 or 54
C
A
B
AR.2
AR.1
RD.1
RD.2
†
RD.2 A B C D Ideal outer radius
Outer Inner
No. of bricks
in quadrant
16
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 22
SL.1 SL.2
Brick face slip Brick bed slip
SL.1 A B C
SL.1.1 215 25 65
SL.1.2 215 30 65
SL.1.3 215 40 65
C A C
A SL.1.4 215 50 65
B
B
SL.2 A B C
SL.2 215 102 25
SD.2
SD.3
SD.1
SL.1
NS.1 SL.2
SD.2 A B C D E
D D D D
B C SD.2.1 215 102 102 46 159
SD.2.2 215 102 102 60 173
45˚ SD.3 A B C D E
A
A SD.3.1 215 102 102 46 159
A E
SD.3.2 215 102 102 60 173
E
B C B C
NS.1 A B C
Group NS NON-STANDARD CUBOID BRICKS NS.1.1 190 90 90
NS.1.2 290 90 65
NS.1.3 290 90 90
NS.1 NS.1.4 215 102 50
17
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 23
PL.33.21 PL.33.22
Plinth stretcher Wide bed plinth stretcher
E
E
α
α
D
C D
C
A
B A
B
PL.33 A B C D E a
PL.33.21 215 102 65 23 46 37°
PL.33.22 215 158 65 23 102 37°
PL.33.38 215 158 65 23 102 37°
PL.33.52 159 102 65 23 46 37°
PL.33.53 159 158 65 23 102 37°
PL.33.56 159 102 65 23 46 37°
PL33.38
Wide bed plinth stretcher faced to side PL.33.53
E PL.33.22 PL.33.38
PL.33.56
α
D C
A
B
RH shown
PL.33.52
PL.33.21
α
α α
D C
C
D D C
A
B A B A
B
RH shown
18
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 24
PL.32.38 PL.32.49
Plinth header faced to side Plinth header (1⁄ 2 length)
E
E
α
α C
C
D
D
A B A
B
RH shown
PL.32 A B C D E a
PL.32.38 215 102 65 23 158 37°
PL.32.49 102 102 65 23 46 37°
PL.32.50 158 102 65 23 102 37°
PL.32.50 PL.35.24
Plinth header (3⁄ 4 length) PL.37.38
E PL.32.50
PL.32.49
α
C
D
A
B
PL.32.38
PL.35 A B C D E a
PL.35.24 PL.37.38 PL.35.24 158 158 65 23 102 37°
Plinth internal return Plinth external return
E
PL.37 A B C D E a
E E E
PL.37.38 158 158 65 23 102 37°
C C
α D
A B A B
D
19
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 25
SD.34.21 SD.35.21
Soldier external angle Soldier internal angle
A A
SD.34 A B C D a
SD.34.21 215 102 65 65 45°
B B
α D
SD.35 A B C D a
C C D SD.35.21 215 102 65 65 45°
SD.36 A B C D E F a
SD.36.21 215 102 65 65 46 159 45°
SD.36.22 215 102 65 65 60 173 45°
SD.36
Canted soldier external angle
SD.35 SD.34
A
SD.37 SD.36
F
SD.38
α
B D
α
SD.38 A B C D E
C B SD.38.21 215 102 102 46 46
SD.38.22 215 102 102 60 60
E
A
F
E D
C D
20
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:18 pm Page 26
MS.31.21 MS.32.21
Rebated Stretcher Rebated Soldier
B
B
A A
D
E
D
C
E
MS.31 A B C D E
MS.31.21 215 102 65 20 25
MS.32 A B C D E
MS.32.21 215 102 65 20 25
MS.32
MS.31
AN.35 AN.37
E AN.37 A B C D E
E E
AN.37.21 140 140 140 50 50
AN.37.22 150 150 215 65 60
B
α
C
D D
A
C
A B
21
3350 SPECIALS BRO (P) 12/01/00 13/1/00 3:17 pm Page 1
A Commitment to Quality
FM 10354/10355/10356