Sie sind auf Seite 1von 209

Structural Design Calculations

Prepared For:
New Residence
247 20th Street
Santa Monica CA. 90405

March 12, 2018

Avila Structural Consultants, Inc. *15315 Magnolia Blvd. #429,Sherman Oaks CA 91403 *
Cell 818-489-4076 * www.AvilaEngineers.com
Contents
APPENDIX I............................................................................................................................................................ 03
Seismic & Wind Calculations ............................................................................................................................ 03
APPENDIX II .......................................................................................................................................................... 19
Beam Calculations ............................................................................................................................................. 19
APPENDIX III ......................................................................................................................................................... 91
Knee Brace Calculations ................................................................................................................................... 91
APPENDIX IV ......................................................................................................................................................... 95
IV.I - Wood Post Verification ............................................................................................................................. 95
IV.II - Steel Column Calculation........................................................................................................................ 99
APPENDIX V .......................................................................................................................................................... 116
Ledger Calculations ........................................................................................................................................... 116
APPENDIX VI ......................................................................................................................................................... 119
VI.I - Footing Calculations ................................................................................................................................. 119
VI.II - Pad Requirement ..................................................................................................................................... 126
VI.III - Pad Calculations ..................................................................................................................................... 128
VI.IV – Retaining Wall Calculations.................................................................................................................. 137

2 of 209
APPENDIX I

Seismic & Wind Calculations

3 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

1 1) Roof
2 Trusses @ 24" O.C. 3.5
3 Metal Roofing 3.0
4 5/8" OSB Sheathing 3.2
5 Insulation 1.0
6 Misc. 1.8
7 Total 12.5 Lb/Sq.ft
8 2) Ceiling DL
9 2X6 C.J. @ 16" O.C. 2.1
10 5/8" Thick Drywall 3.2
11 Misc. 0.7
12 Total 6.0 Lb/Sq.ft
13 3) Floor DL
14 3/4" Plywood Sub Floor 3.0
15 5/8" Thick Drywall 3.2
16 Insulation 1.0
17 1.5" Concrete Light Weight 16.0
18 14" TJI @ 16 O.C. 3.2
19 Misc. 3.6
20 Total 30.0 Lb/Sq.ft
21 4) Ext. Wall DL
22 Studs 2X6 @ 16" O.C. 2.0
23 Stucco 10.0
24 1/2" OSB Sheathing 1.5
25 5/8" Thick Drywall 3.2
26 Insulation 1.0
27 Misc. 0.8
28 Total 18.5 Lb/Sq.ft
0
0
0
0
LIVE LOADS
Roof = 20.0 lb/sq.ft 5 Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft 6 er Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft 7 Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft 8 Bathroom = 40.0 lb/sq.ft

4 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

29 5) Int. Wall
30 Studs 2X6 @ 16" O.C. 2.0
31 1/2" OSB Sheathing 1.5
32 5/8" Thick Drywall 3.2
33 Insulation 1.0
34 Misc. 0.8
35 Total 8.5 Lb/Sq.ft
36 6) Trellis DL
37 2- 3x6 T.J. @18" O.C. 4.0
38 Misc. 1.0
39 Total 5.0 Lb/Sq.ft
40 7) Lower Roof DL
41 2x8 R.R. @16" O.C. 2.6
42 Metal Roofing 3.0
43 5/8" OSB Sheathing 3.2
44 Insulation 1.0
45 Misc. 0.7
46 Total 10.5 Lb/Sq.ft
47 8) Brick Veneer Ext. Wall DL
48 2x6 Studs @ 16" O.C. 1.5
49 1/2" Thick Interior Dry Wall 1.5
50 5/8" Thick Interior Dry Wall 3.2
51 Brick Veneer 14.0
52 Insulation 1.0
53 Misc. 0.8
54 Total 22.0 Lb/Sq.ft
0
0
0
0
0
0
LIVE LOADS
Roof = 20.0 lb/sq.ft Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft Brick Veneer Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft Bathroom = 40.0 lb/sq.ft

5 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

55 9) Deck
56 2" Concrete Light Weight 16.0
57 1 1/8" CDX Plywood 3.5
58 2x12 @16" O.C. 3.2
59 5/8" Thick Dry Wall 3.2
60 Misc. 0.6
61 Total 26.5 Lb/Sq.ft
62 10) Bathroom DL
63 3/4" Plywood Sub Floor 2.1
64 Tile 10.0
65 1 1/2" Leveling Concret 12.0
66 5/8" Thick Dry Wall 3.2
67 2x12 @16" O.C. 3.9
68 Misc. 0.8
69 Insulation 1.0
70 Total 33.0 Lb/Sq.ft
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
LIVE LOADS
Roof = 20.0 lb/sq.ft Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft Brick Veneer Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft Bathroom = 40.0 lb/sq.ft

6 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

SEISMIC LOADS: AREA A


Roof DL: 12.5 lbs./sq.ft. Trellis DL: 5.0 lbs./sq.ft.
Ceiling DL: 6.0 lbs./sq.ft. Lower Roof DL: 10.5 lbs./sq.ft.
Floor DL: 30.0 lbs./sq.ft. Brick Ven. Ext Wall DL: 22.0 lbs./sq.ft.
Ext. Wall DL: 18.5 lbs./sq.ft. Deck DL: 26.5 lbs./sq.ft.
Int. Wall DL: 8.5 lbs./sq.ft. Bathroom DL: 33.0 lbs./sq.ft.

ROOF LEVEL DEAD WEIGHT


Total Length (Ft.) H (Ft.) AREA DL (PSF) WEIGHT [Lbs]
Roof - - 2750 12.5 34375 Lbs
Ext. Wall 139.0 5.0 130 18.5 2405 Lbs
Int. Wall 160.75 5.0 161 8.5 1366 Lbs.
TOTAL ROOF DIAPHRAGM AREA 2750 Sq.ft. 38146 Lbs

7 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

SEISMIC LOADS: AREA A

2nd FLOOR LEVEL DEAD WEIGHT


Total Length (Ft.) H (Ft.) AREA DL (PSF) WEIGHT [Lbs]
Ext. Wall (Abv) 139.0 4.5 626 18.5 11572 Lbs
Int. Wall (Abv) 160.75 4.5 723 8.5 6149 Lbs
Lower Roof - - 1010 10.5 10605 Lbs
Floor - - 2046 30.0 61380 Lbs
Bathroom - - 260 33.0 8580 Lbs
Deck - - 180 26.5 4770 Lbs
Ext. Wall (Bel) 175.0 4.5 788 22.0 17325 Lbs
Int. Wall (Bel) 140.0 4.5 630 8.5 5355 Lbs
TOTAL FLOOR DIAPHRAGM AREA 3496 Sq.ft. 125735 Lbs

1st FLOOR LEVEL DEAD WEIGHT


Total Length (Ft.) H (Ft.) AREA DL (PSF) WEIGHT [Lbs]
Ext. Wall (Abv) 175.0 4.5 788 22.0 17325 Lbs
Int. Wall (Abv) 140.0 4.5 630 8.5 5355 Lbs
Floor - - 2224 30.0 66720 Lbs
Bath - - 100.0 33.0 3300 Lbs
Ext. Wall (Bel) 23.5 4.5 106 18.5 1956 Lbs
Int. Wall (Bel) 151.5 4.5 682 8.5 5795 Lbs
TOTAL FLOOR DIAPHRAGM AREA 2324 Sq.ft. 100451 Lbs

8 of 209
1/2/2018 Design Maps Summary Report

Design Maps Summary Report


User–Specified Input
Report Title Santa Monica
Tue January 2, 2018 22:21:13 UTC

Building Code Reference Document ASCE 7-10 Standard


(which utilizes USGS hazard data available in 2008)

Site Coordinates 34.04315°N, 118.49707°W


Site Soil Classification Site Class D – “Stiff Soil”
Risk Category I/II/III

USGS–Provided Output

SS = 2.172 g SMS = 2.172 g SDS = 1.448 g


S1 = 0.804 g SM1 = 1.207 g SD1 = 0.804 g

For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the “2009 NEHRP” building code reference document.

9 of 209
https://earthquake.usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=34.043149&longitude=-118.497065&siteclass=3&riskcateg… 1/2
1/2/2018 Design Maps Summary Report

For PGAM, TL, CRS, and CR1 values, please view the detailed report.

Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the
accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge.

10 of 209
https://earthquake.usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=34.043149&longitude=-118.497065&siteclass=3&riskcateg… 2/2
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

AREA A
SEISMIC ANALYSIS BASED ON IBC 2015 (Equivalent Lateral-Force Procedure, ASCE 7-10 12.8)
INPUT DATA
Typical floor height h= 9.0 Ft.
Typical floor weight wx = 88,111 Lbs
Number of floors n= 3
Importance factor (ASCE 11.5.1) I= 1 (IBC Tab.1604.5)
Building location 247 20th Street, Santa Monica, CA 90405
Site class (A, B, C, D, E, F) D (If no soil report, use D)
The coefficient (ASCE Tab 12.8-2) Ct = 0.02
The coefficient(ASCE Tab. 12.2.1) R= 6.50
Seismic design category E
Latitude: 34.04 Longitude: -118.50
SS = 217.20 %g, Sms = 2.172 g , Fa = 1.0
S1 = 80.40 %g, Sm1 = 1.206 g , Fv = 1.5
SDS = 1.448 g, SD1 = 0.804 g
hn = 27 Ft k = 1.00 , (ASCE 12.8.3, pg 130)
x = 0.75 , (ASCE Tab 12.8-2) Ta = Ct (hn)x = 0.24 Sec, (ASCE 12.8.2.1)

W = 264,333 Lbs wxhk = 4,361,133

DESIGN SUMMARY
SD
V = Cs*W Cs = 0.22 V= 58,885 Lbs
E=V*ρ= E = 58885,3 Lbs * ρ = 76,551 Lbs

VERTICAL DISTRIBUTION OF LATERAL FORCES


Level Level Floor to Height Weight Lateral force
No. Name floor Height hx wx wxhxk Cvx Fx Vx
Ft. Ft. Lbs Lbs Lbs
3 Roof 9.0 28.0 38146 1,068,099 0.25 18,755 18,755
2 2 10.0 19.0 125735 2,388,973 0.55 41,950 60,705
1 1 9.0 9.0 100451 904,061 0.21 15,846 76,551

DIAPHRAGM FORCES
Level Fi W i Fpx Redundancy factor (ASCE 12.3.4)
Name Lbs Lbs Lbs ρ= 1.3
Roof 18,755.0 38,146 18,755
2nd Floor 60,704.8 163,882 46,575
1st Floor 76,550.9 264,333 29,091

11 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

2-STORY BUILDING WIND DISTRIBUTION

Area A
hb = 6.50 Ft. hr = hb + he2 + hf + he1 = 26.67 Ft.
he2 = 9.00 Ft. he = he2 + hf + he1 = 20.17 Ft.
hf = 1.17 Ft. hb + he2/2= 11.00 Ft.
he1 = 10.00 Ft. he2/2 + hf + he1/2= 10.67 Ft.
hf1 = 1.00 Ft. he1/2= 5.00 Ft.
L= 77.50 Ft.
B= 38.00 Ft.

(*) Max horizontal wind force normal to building length, L, face = 34740 Lbs.
* See Wind Analysis for Low-rise Building (Area A)

Design wind force normal to bulding length, L, face=


Roof Diaphragm Tributary Wind Force = (11 Ft. / 26,67 Ft.) * 34740 Lbs. = 14328 Lbs.
2nd Floor Diaphragm Tributary Wind Force = (10,67 Ft. / 26,67 Ft.) * 34740 Lbs. = 13899 Lbs.
1st Floor Diaphragm Tributary Wind Force = (5 Ft. / 26,67 Ft.) * 34740 Lbs. = 6513 Lbs.

(*) Max horizontal wind force normal to building length, B, face = 16350 Lbs.
* See Wind Analysis for Low-rise Building (Area A)

Design wind force normal to bulding length, B, face=


Roof Diaphragm Tributary Wind Force = (11 Ft. / 26,67 Ft.) * 16350 Lbs. = 6744 Lbs.
2nd Floor Diaphragm Tributary Wind Force = (10,67 Ft. / 26,67 Ft.) * 16350 Lbs. = 6541 Lbs.
1st Floor Diaphragm Tributary Wind Force = (5 Ft. / 26,67 Ft.) * 16350 Lbs. = 3065 Lbs.

12 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

AREA A
Y-Y SEISMIC-WIND DESIGN FORCES COMPARISON
Seismic Cumulative Wind Load Cumulative Load per sq.
Level Area (Ft2) Govern
Loads (Lbs) Load (Lbs) (Lbs) Load (Lbs) ft (lb/ft2)

Roof 2750 18755 18755 14328 14328 Seismic 7


2nd Floor 3496 41950 60705 13899 28227 Seismic 12
1st Floor 2324 15846 76551 6513 34740 Seismic 7

X-X SEISMIC-WIND DESIGN FORCES COMPARISON


Seismic Cumulative Wind Load Cumulative Load per sq.
Level Area Govern
Loads (Lbs) Load (Lbs) (Lbs) Load (Lbs) ft (lb/ft2)

Roof 2750 18755 18755 6744 6744 Seismic 7


2nd Floor 3496 41950 60705 6541 13285 Seismic 12
1st Floor 2324 15846 76551 3065 16350 Seismic 7

13 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

Design Wood Shear Wall Hardy Frame


Shear Above
Shear Area Load Trib. Shear Total Unit Floor to Floor Strap or
TYP. Force Level Shear Total Uplift Lbs.
Line Designation (lbs/ft2) Area (ft2) Force Length Shear Sizes Capacity Quantity Holdown
(Lbs.) Shear Wall ID Capacity
(Lbs.) (FT.) #/Ft.

ROOF LEVEL Y-Y


HDU2-SDS2.5 w/ 5/8"
1 A 7 Seismic 646 4406 0 4406 20.00 220 1 N.A. - - - 1786
Thr. Rod
HDU8-SDS2.5 w/ 7/8"
2 A 7 Seismic 852 5811 0 5811 8.25 704 3 N.A. - - - 6221
Thr. Rod
HDU5-SDS2.5 w/ 5/8"
4 A 7 Seismic 729 4972 0 4972 8.25 603 3 N.A. - - - 5306
Thr. Rod
HDU2-SDS2.5 w/ 5/8"
5 A 7 Seismic 523 3567 0 3567 11.33 315 1 N.A. - - - 2370
Thr. Rod
2nd FLOOR LEVEL Y-Y
HDU14-SDS2.5 w/ 1"
0 A 12 Seismic 713 8556 4406 12961 10.25 1265 6 N.A. - - - 11714
Thr. Rod
HDU14-SDS2.5 w/ 1"
2 A 12 Seismic 974 11687 5811 17498 14.50 1207 6 N.A. - - - 10685
Thr. Rod
HDU2-SDS2.5 w/ 5/8"
3 A 12 Seismic 267 3204 0 3204 10.50 305 1 N.A. - - - 1872
Thr. Rod
HDU14-SDS2.5 w/ 1"
4 A 12 Seismic 755 9060 6220 15280 10.50 1455 7 N.A. - - - 11723
Thr. Rod
HDU14-SDS2.5 w/ 1"
6 A 12 Seismic 642 7704 2318 10022 7.50 1336 6 N.A. - - - 12691
Thr. Rod
1st FLOOR LEVEL Y-Y
HDU5-SDS2.5 w/ 5/8"
3 A 7 Seismic 544 3709 3204 6913 9.75 709 3 N.A. - - - 5885
Thr. Rod
HD19-(5) 1" w/ 1 1/8"
4 A 7 Seismic 712 4855 15280 20134 9.75 2065 7 N.A. - - - 19009
Thr. Rod.

14 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

Design Wood Shear Wall Hardy Frame


Shear Above
Shear Area Load Trib. Shear Total Unit Floor to Floot Strap or
TYP. Force Level Shear Total Uplift Lbs.
Line Designation (lbs/ft2) Area (ft2) Force Length Shear Sizes Capacity Quantity Holdown
(Lbs.) Shear Wall ID Capacity
(Lbs.) (FT.) #/Ft.
ROOF LEVEL X-X
HDU2-SDS2.5 w/ 5/8"
A A 7 Seismic 1473 10046 0 10046 29.50 341 1 N.A. - - - 3229
Thr. Rod
HDU2-SDS2.5 w/ 5/8"
C A 7 Seismic 1277 8709 0 8709 24.75 352 1 N.A. - - - 2434
Thr. Rod
2nd FLOOR LEVEL X-X
HDU2-SDS2.5 w/ 5/8"
A' A 12 Seismic 167 2004 0 2004 28.00 72 1 N.A. - - - 274
Thr. Rod
HDU11-SDS2.5 w/ 1"
A A 12 Seismic 966 11591 10046 21637 30.50 709 3 N.A. - - - 6526
Thr. Rod
HDU2-SDS2.5 w/ 5/8"
B A 12 Seismic 1459 17507 0 17507 26.33 665 3 N.A. - - - 328
Thr. Rod
HDU4-SDS2.5 w/ 5/8"
C A 12 Seismic 254 3048 8709 11757 26.00 452 2 N.A. - - - 4101
Thr. Rod
HDU5-SDS2.5 w/ 5/8"
D A 12 Seismic 402 4824 0 4824 8.50 568 3 N.A. - - - 5005
Thr. Rod
1st FLOOR LEVEL X-X
HDU8-SDS2.5 w/ 7/8"
C A 7 Seismic 526 3586 11757 15343 15.75 974 5 N.A. - - - 6252
Thr. Rod

15 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

EXAMPLE HOLDOWN DESIGN


SHEAR LINE: 1 - Roof
B= 6.50 ft.
Qe = Shear/ft x B
L = Tributary Width = 1.33 ft.

Roof Dead Load (t) = 12.50 lbs/sq.ft


Wall Dead Load (w) = 18.50 lbs/sq.ft
H= 9.00 ft. W DL Floor Dead Load (f) = 30.00 lbs/sq.ft
W RF Unit Shear = 220.29 lbs/ft
W FL Qe = Shear/ft = 1431.86 lbs
SDS = 1.45
A CS = 0.22
(Hillside Dir.)
FHD FHD

W RF = B xL x t= 108 Lbs. Roof Dead Load


W DL = B x H x w= 1082 Lbs. Wall Dead Load
W FL = B x L x f= 0 Lbs. Floor Dead Load

∗ ∗ ∗2 0.9 0.2 ∗ ∗ ∗2 ∗2 ∗2

F HD = 1786 lbs.

HOLDOWN

HDU2-SDS2.5 w/ 5/8" Thr. Rod Allowable Capacity= 2306 Lbs.


SD factor = 1.4
Ultimate Capacity= 2306,25 lbs * 1,4 = 3228.75 Lbs.

1786 Lbs. < 3228.8 Lbs. OK HDU2-SDS2.5 w/ 5/8" Thr. Rod

16 of 209
Avila Structural Consultants, Inc.
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91302 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

HOLDOWN DESIGN
Roof Dead Load (t) = 12.50 lbs/sq.ft SDS = 1.45
Wall Dead Load (w) = 18.50 lbs/sq.ft CS = 0.22
Floor Dead Load (f) = 30.00 lbs/sq.ft

W RF W DL W FL Shear F HD Holdown Capacity


Line Level B [ft.] H [ft.] L [ft.] Status
[lbs] [lbs] [lbs] [lbs/ft] [Lbs.] Strap [Lbs.]

ROOF LEVEL Y-Y

1 Roof 6.50 9.00 1.33 108 1082 0 220 1786 HDU2-SDS2.5 w/ 5/8" Thr. Rod 3229 OK

2 Roof 8.25 9.00 1.33 55 549 0 704 6221 HDU8-SDS2.5 w/ 7/8" Thr. Rod 6279 OK

4 Roof 8.25 9.00 1.33 55 549 0 603 5306 HDU5-SDS2.5 w/ 5/8" Thr. Rod 5927 OK

5 Roof 14.83 9.00 1.33 99 988 0 315 2370 HDU2-SDS2.5 w/ 5/8" Thr. Rod 3229 OK

2nd FLOOR LEVEL Y-Y

0 2nd Floor 10.25 10.00 4.33 555 1896 555 1265 11714 HDU14-SDS2.5 w/ 1" Thr. Rod 49434 OK

2 2nd Floor 14.50 10.00 1.33 241 2683 579 1207 10685 HDU14-SDS2.5 w/ 1" Thr. Rod 43876 OK

3 2nd Floor 10.50 10.00 1.33 175 1943 419 305 1872 HDU2-SDS2.5 w/ 5/8" Thr. Rod 20790 OK

4 2nd Floor 10.50 10.00 10.83 1421 1943 3411 1455 11723 HDU14-SDS2.5 w/ 1" Thr. Rod 15094 OK

6 2nd Floor 7.50 10.00 5.17 485 1388 1163 1336 12691 HDU14-SDS2.5 w/ 1" Thr. Rod 15094 OK

1st FLOOR LEVEL Y-Y

3 1st Floor 9.75 9 1.33 162 1623 389 709 5885 HDU5-SDS2.5 w/ 5/8" Thr. Rod 5927 OK

4 1st Floor 9.75 9 1.33 65 649 389 2065 19009 HD19-(5) 1" w/ 1 1/8" Thr. Rod. 26698 OK

17 of 209
Avila Structural Consultants, Inc.
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91302 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

HOLDOWN DESIGN
ROOF LEVEL X-X

A Roof 8.00 9.00 10.83 1083 1332 0 341 2495 HDU2-SDS2.5 w/ 5/8" Thr. Rod 3229 OK

C Roof 11.33 9.00 7.50 1062 1886 0 352 2434 HDU2-SDS2.5 w/ 5/8" Thr. Rod 3229 OK

2nd FLOOR LEVEL X-X

A' 2nd Floor 6.50 10.00 3.33 271 1203 649 72 274 HDU2-SDS2.5 w/ 5/8" Thr. Rod 39500 OK

A 2nd Floor 10.50 10.00 1.33 175 1943 419 709 6526 HDU11-SDS2.5 w/ 1" Thr. Rod 10012 OK

B 2nd Floor 24.33 10.00 16.33 4966 4501 11919 665 328 HDU2-SDS2.5 w/ 5/8" Thr. Rod 3229 OK

C 2nd Floor 8.50 10.00 1.33 141 1573 339 452 4101 HDU4-SDS2.5 w/ 5/8" Thr. Rod 4793 OK

D 2nd Floor 8.42 10.00 3.67 386 1558 927 568 5005 HDU5-SDS2.5 w/ 5/8" Thr. Rod 5927 OK

1st FLOOR LEVEL X-X

C 1st Floor 15.75 9 7.50 1477 2622 3544 974 6252 HDU8-SDS2.5 w/ 7/8" Thr. Rod 6279 OK

18 of 209
APPENDIX II

Beam Calculations

19 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

1 1) Roof
2 Trusses @ 24" O.C. 3.5
3 Metal Roofing 3.0
4 5/8" OSB Sheathing 3.2
5 Insulation 1.0
6 Misc. 1.8
7 Total 12.5 Lb/Sq.ft
8 2) Ceiling DL
9 2X6 C.J. @ 16" O.C. 2.1
10 5/8" Thick Drywall 3.2
11 Misc. 0.7
12 Total 6.0 Lb/Sq.ft
13 3) Floor DL
14 3/4" Plywood Sub Floor 3.0
15 5/8" Thick Drywall 3.2
16 Insulation 1.0
17 1.5" Concrete Light Weight 16.0
18 14" TJI @ 16 O.C. 3.2
19 Misc. 3.6
20 Total 30.0 Lb/Sq.ft
21 4) Ext. Wall DL
22 Studs 2X6 @ 16" O.C. 2.0
23 Stucco 10.0
24 1/2" OSB Sheathing 1.5
25 5/8" Thick Drywall 3.2
26 Insulation 1.0
27 Misc. 0.8
28 Total 18.5 Lb/Sq.ft
0
0
0
0
LIVE LOADS
Roof = 20.0 lb/sq.ft 5 Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft 6 er Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft 7 Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft 8 Bathroom = 40.0 lb/sq.ft

20 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

29 5) Int. Wall
30 Studs 2X6 @ 16" O.C. 2.0
31 1/2" OSB Sheathing 1.5
32 5/8" Thick Drywall 3.2
33 Insulation 1.0
34 Misc. 0.8
35 Total 8.5 Lb/Sq.ft
36 6) Trellis DL
37 2- 3x6 T.J. @18" O.C. 4.0
38 Misc. 1.0
39 Total 5.0 Lb/Sq.ft
40 7) Lower Roof DL
41 2x8 R.R. @16" O.C. 2.6
42 Metal Roofing 3.0
43 5/8" OSB Sheathing 3.2
44 Insulation 1.0
45 Misc. 0.7
46 Total 10.5 Lb/Sq.ft
47 8) Brick Veneer Ext. Wall DL
48 2x6 Studs @ 16" O.C. 1.5
49 1/2" Thick Interior Dry Wall 1.5
50 5/8" Thick Interior Dry Wall 3.2
51 Brick Veneer 14.0
52 Insulation 1.0
53 Misc. 0.8
54 Total 22.0 Lb/Sq.ft
0
0
0
0
0
0
LIVE LOADS
Roof = 20.0 lb/sq.ft Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft Brick Veneer Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft Bathroom = 40.0 lb/sq.ft

21 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

55 9) Deck
56 2" Concrete Light Weight 16.0
57 1 1/8" CDX Plywood 3.5
58 2x12 @16" O.C. 3.2
59 5/8" Thick Dry Wall 3.2
60 Misc. 0.6
61 Total 26.5 Lb/Sq.ft
62 10) Bathroom DL
63 3/4" Plywood Sub Floor 2.1
64 Tile 10.0
65 1 1/2" Leveling Concret 12.0
66 5/8" Thick Dry Wall 3.2
67 2x12 @16" O.C. 3.9
68 Misc. 0.8
69 Insulation 1.0
70 Total 33.0 Lb/Sq.ft
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
LIVE LOADS
Roof = 20.0 lb/sq.ft Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft Brick Veneer Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft Bathroom = 40.0 lb/sq.ft

22 of 209
MEMBER REPORT Level, Floor: Joist Span #1 PASSED
1 piece(s) 14" TJI® 560 @ 16" OC

All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor

Member Reaction (lbs) 1023 @ 5 1/2" 1265 (1.75") Passed (81%) 1.00 1.0 D + 1.0 L (All Spans) Member Type : Joist

Shear (lbs) 1023 @ 5 1/2" 2390 Passed (43%) 1.00 1.0 D + 1.0 L (All Spans) Building Use : Residential

Moment (Ft-lbs) 5604 @ 11' 5" 11275 Passed (50%) 1.00 1.0 D + 1.0 L (All Spans) Building Code : IBC 2009

Live Load Defl. (in) 0.307 @ 11' 5" 0.731 Passed (L/856) -- 1.0 D + 1.0 L (All Spans) Design Methodology : ASD

Total Load Defl. (in) 0.538 @ 11' 5" 0.548 Passed (L/489) -- 1.0 D + 1.0 L (All Spans)
TJ-ProŒRating 44 40 Passed -- --
‡ Deflection criteria: LL (L/360) and TL (L/480).
‡ Top Edge Bracing (Lu): Top compression edge must be braced at 8' 2" o/c unless detailed otherwise.
‡ Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 21' 11" o/c unless detailed otherwise.
‡ A structural analysis of the deck has not been performed.
‡ Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeŒPanel (24" Span Rating) that is glued and nailed down.
‡ Additional considerations for the TJ-ProŒRating include: None

Bearing Length Loads to Supports (lbs)

Supports Floor
Total Available Required Dead Total Accessories
Live
1 - Hanger on 14" PSL beam 5.50" Hanger¹ 1.75" / - ² 457 609 1066 See note ¹
2 - Hanger on 14" PSL beam 5.50" Hanger¹ 1.75" / - ² 457 609 1066 See note ¹
‡ At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
‡ ¹ See Connector grid below for additional information and/or requirements.
‡ ² Required Bearing Length / Required Bearing Length with Web Stiffeners

Connector: Simpson Strong-Tie Connectors


Support Model Seat Length Top Nails Face Nails Member Nails Accessories
1 - Face Mount Hanger IUS3.56/14 2.00" N/A 12-10d x 1-1/2 N/A
2 - Face Mount Hanger IUS3.56/14 2.00" N/A 12-10d x 1-1/2 N/A

Dead Floor Live


Loads Location (Side) Spacing (0.90) (1.00) Comments
Residential - Living
1 - Uniform (PSF) 0 to 22' 10" 16" 30.0 40.0
Areas

Member Notes
14 T.J.I

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator

Forte Software Operator Job Notes 3/11/2018 5:35:11 PM


José Ignacio Salim
Forte v5.3, Design Engine: V7.0.0.5
G.E.D. TJI.4te
(818) 530-1248
jose@gedconsultants.com
23 ofPage
209 1 of 1
MEMBER REPORT Level, Floor: Joist Span#2 PASSED
1 piece(s) 14" TJI® 560 @ 16" OC

All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor

Member Reaction (lbs) 933 @ 5 1/2" 1265 (1.75") Passed (74%) 1.00 1.0 D + 1.0 L (All Spans) Member Type : Joist

Shear (lbs) 933 @ 5 1/2" 2390 Passed (39%) 1.00 1.0 D + 1.0 L (All Spans) Building Use : Residential

Moment (Ft-lbs) 4667 @ 10' 5 1/2" 11275 Passed (41%) 1.00 1.0 D + 1.0 L (All Spans) Building Code : IBC 2009

Live Load Defl. (in) 0.219 @ 10' 5 1/2" 0.667 Passed (L/999+) -- 1.0 D + 1.0 L (All Spans) Design Methodology : ASD

Total Load Defl. (in) 0.383 @ 10' 5 1/2" 0.500 Passed (L/627) -- 1.0 D + 1.0 L (All Spans)
TJ-ProŒRating 50 40 Passed -- --
‡ Deflection criteria: LL (L/360) and TL (L/480).
‡ Top Edge Bracing (Lu): Top compression edge must be braced at 9' o/c unless detailed otherwise.
‡ Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 20' o/c unless detailed otherwise.
‡ A structural analysis of the deck has not been performed.
‡ Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeŒPanel (24" Span Rating) that is glued and nailed down.
‡ Additional considerations for the TJ-ProŒRating include: None

Bearing Length Loads to Supports (lbs)

Supports Floor
Total Available Required Dead Total Accessories
Live
1 - Hanger on 14" PSL beam 5.50" Hanger¹ 1.75" / - ² 418 558 976 See note ¹
2 - Hanger on 14" PSL beam 5.50" Hanger¹ 1.75" / - ² 418 558 976 See note ¹
‡ At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
‡ ¹ See Connector grid below for additional information and/or requirements.
‡ ² Required Bearing Length / Required Bearing Length with Web Stiffeners

Connector: Simpson Strong-Tie Connectors


Support Model Seat Length Top Nails Face Nails Member Nails Accessories
1 - Face Mount Hanger IUS3.56/14 2.00" N/A 12-10d x 1-1/2 N/A
2 - Face Mount Hanger IUS3.56/14 2.00" N/A 12-10d x 1-1/2 N/A

Dead Floor Live


Loads Location (Side) Spacing (0.90) (1.00) Comments
Residential - Living
1 - Uniform (PSF) 0 to 20' 11" 16" 30.0 40.0
Areas

Member Notes
14 T.J.I

Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator

Forte Software Operator Job Notes 3/11/2018 5:38:42 PM


José Ignacio Salim
Forte v5.3, Design Engine: V7.0.0.5
G.E.D. TJI.4te
(818) 530-1248
jose@gedconsultants.com
24 ofPage
209 1 of 1
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

GT1 Girder Truss ‐ Only Reactions Use: -

D1
Z

X D1
Y 7.5
0.7 28.3
Units = ft
Roof        
DL1 = 12,5psf *7,5ft = 93,8 Lbs/ft
Lr1 = 20psf *7,5ft = 150 Lbs/ft
1
GT2 Girder Truss ‐ Only Reactions Use: -

GT1
D1
D2
Z

X
D1 D2
Y 2.7
8.4 20.2 20.9 15.6
Units = ft
Roof        
BEAM SUPP. DL Lr  LL  E Units DL1 = 12,5psf *15,6ft = 194,8 Lbs/ft
GT1 2 1290 2070 0 0 [Lbs] Lr1 = 20psf *15,6ft = 311,6 Lbs/ft
Roof        
DL2 = 12,5psf *2,7ft = 33,3 Lbs/ft
Lr2 = 20psf *2,7ft = 53,2 Lbs/ft
1
GT3 Girder Truss ‐ Only Reactions Use: -

D1
Z

X D1
11.0
Y
22.0 22.8
Units = ft
Roof        
DL1 = 12,5psf *11ft = 137,5 Lbs/ft
Lr1 = 20psf *11ft = 220 Lbs/ft
1

25 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT1

General Beam Properties


Elastic Modulus 29,000.0 ksi
Span #1 Span Length = 0.670 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4
Span #2 Span Length = 27.580 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Loads on all spans...
Uniform Load on ALL spans : D = 0.09380, Lr = 0.150 k/ft, Tributary Width = 1.0 ft

DESIGN SUMMARY .
Maximum Bending = 33.483 k-ft Maximum Shear = 4.865 k
Load Combination +1.20D+1.60Lr+0.50L+1.60H Load Combination +1.20D+1.60Lr+0.50L+1.60H
Span # where maximum occurs Span # 2 Span # where maximum occurs Span # 1
Location of maximum on span 13.790 ft Location of maximum on span 0.670 ft
Maximum Deflection
Max Downward Transient Deflection 0.681 in 486
Max Upward Transient Deflection -0.052 in 306
Max Downward Total Deflection 1.106 in 299
Max Upward Total Deflection -0.085 in 188

Maximum Forces & Stresses for Load Combinations .


Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Overall MAXimum Envelope
Dsgn. L = 0.67 ft 1 -0.08 0.08 4.86
Dsgn. L = 27.58 ft 2 33.48 -0.08 33.48 4.86
+1.40D+1.60H
Dsgn. L = 0.67 ft 1 -0.03 0.03 1.81
Dsgn. L = 27.58 ft 2 12.47 -0.03 12.47 1.81
+1.20D+0.50Lr+1.60L+1.60H
Dsgn. L = 0.67 ft 1 -0.04 0.04 2.59
Dsgn. L = 27.58 ft 2 17.81 -0.04 17.81 2.59
+1.20D+1.60L+0.50S+1.60H
Dsgn. L = 0.67 ft 1 -0.03 0.03 1.55
Dsgn. L = 27.58 ft 2 10.69 -0.03 10.69 1.55
+1.20D+1.60Lr+0.50L+1.60H
Dsgn. L = 0.67 ft 1 -0.08 0.08 4.86
Dsgn. L = 27.58 ft 2 33.48 -0.08 33.48 4.86
+1.20D+1.60Lr+0.50W+1.60H
Dsgn. L = 0.67 ft 1 -0.08 0.08 4.86
Dsgn. L = 27.58 ft 2 33.48 -0.08 33.48 4.86
+1.20D+0.50L+1.60S+1.60H
Dsgn. L = 0.67 ft 1 -0.03 0.03 1.55
Dsgn. L = 27.58 ft 2 10.69 -0.03 10.69 1.55
+1.20D+1.60S+0.50W+1.60H
Dsgn. L = 0.67 ft 1 -0.03 0.03 1.55
Dsgn. L = 27.58 ft 2 10.69 -0.03 10.69 1.55
+1.20D+0.50Lr+0.50L+W+1.60H
Dsgn. L = 0.67 ft 1 -0.04 0.04 2.59
Dsgn. L = 27.58 ft 2 17.81 -0.04 17.81 2.59
+1.20D+0.50L+0.50S+W+1.60H
Dsgn. L = 0.67 ft 1 -0.03 0.03 1.55
Dsgn. L = 27.58 ft 2 10.69 -0.03 10.69 1.55 26 of 209
+1.20D+0.50L+0.20S+E+1.60H
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT1

Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Dsgn. L = 0.67 ft 1 -0.03 0.03 1.55
Dsgn. L = 27.58 ft 2 10.69 -0.03 10.69 1.55
+0.90D+W+0.90H
Dsgn. L = 0.67 ft 1 -0.02 0.02 1.16
Dsgn. L = 27.58 ft 2 8.02 -0.02 8.02 1.16
+0.90D+E+0.90H
Dsgn. L = 0.67 ft 1 -0.02 0.02 1.16
Dsgn. L = 27.58 ft 2 8.02 -0.02 8.02 1.16
Overall Maximum Deflections .
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
1 0.0000 0.000 +D+Lr+H -0.0849 0.000
+D+Lr+H 2 1.1063 14.002 0.0000 0.000
.
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2 Support 3
Overall MAXimum 3.527 3.360
Overall MINimum 0.814 0.776
+D+H 1.357 1.293
+D+L+H 1.357 1.293
+D+Lr+H 3.527 3.360
+D+S+H 1.357 1.293
+D+0.750Lr+0.750L+H 2.985 2.843
+D+0.750L+0.750S+H 1.357 1.293
+D+0.60W+H 1.357 1.293
+D+0.70E+H 1.357 1.293
+D+0.750Lr+0.750L+0.450W+H 2.985 2.843
+D+0.750L+0.750S+0.450W+H 1.357 1.293
+D+0.750L+0.750S+0.5250E+H 1.357 1.293
+0.60D+0.60W+0.60H 0.814 0.776
+0.60D+0.70E+0.60H 0.814 0.776
D Only 1.357 1.293
Lr Only 2.170 2.067
L Only
S Only
W Only
E Only
H Only

27 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT2

General Beam Properties


Elastic Modulus 29,000.0 ksi
Span #1 Span Length = 20.250 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4
Span #2 Span Length = 0.670 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Load for Span Number 1
Uniform Load : D = 0.1948, Lr = 0.3116 k/ft, Extent = 0.0 -->> 8.420 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.03330, Lr = 0.05320 k/ft, Extent = 8.420 -->> 20.250 ft, Tributary Width = 1.0 ft

Load for Span Number 2


Uniform Load : D = 0.03330, Lr = 0.05320 k/ft, Tributary Width = 1.0 ft

DESIGN SUMMARY .
Maximum Bending = 19.286 k-ft Maximum Shear = 5.315 k
Load Combination +1.20D+1.60Lr+0.50L+1.60H Load Combination +1.20D+1.60Lr+0.50L+1.60H
Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1
Location of maximum on span 7.321 ft Location of maximum on span 0.000 ft
Maximum Deflection
Max Downward Transient Deflection 0.197 in 1235
Max Upward Transient Deflection -0.019 in 864
Max Downward Total Deflection 0.320 in 760
Max Upward Total Deflection -0.030 in 532

Maximum Forces & Stresses for Load Combinations .


Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Overall MAXimum Envelope
Dsgn. L = 20.25 ft 1 19.29 -0.03 19.29 5.32
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+1.40D+1.60H
Dsgn. L = 20.25 ft 1 7.18 -0.01 7.18 1.98
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+0.50Lr+1.60L+1.60H
Dsgn. L = 20.25 ft 1 10.26 -0.01 10.26 2.83
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.04
+1.20D+1.60L+0.50S+1.60H
Dsgn. L = 20.25 ft 1 6.16 -0.01 6.16 1.70
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+1.60Lr+0.50L+1.60H
Dsgn. L = 20.25 ft 1 19.29 -0.03 19.29 5.32
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+1.20D+1.60Lr+0.50W+1.60H
Dsgn. L = 20.25 ft 1 19.29 -0.03 19.29 5.32
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+1.20D+0.50L+1.60S+1.60H
Dsgn. L = 20.25 ft 1 6.16 -0.01 6.16 1.70
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+1.60S+0.50W+1.60H
Dsgn. L = 20.25 ft 1 6.16 -0.01 6.16 1.70 28 of 209
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT2

Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
+1.20D+0.50Lr+0.50L+W+1.60H
Dsgn. L = 20.25 ft 1 10.26 -0.01 10.26 2.83
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.04
+1.20D+0.50L+0.50S+W+1.60H
Dsgn. L = 20.25 ft 1 6.16 -0.01 6.16 1.70
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+0.50L+0.20S+E+1.60H
Dsgn. L = 20.25 ft 1 6.16 -0.01 6.16 1.70
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+0.90D+W+0.90H
Dsgn. L = 20.25 ft 1 4.62 -0.01 4.62 1.27
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.02
+0.90D+E+0.90H
Dsgn. L = 20.25 ft 1 4.62 -0.01 4.62 1.27
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.02
Overall Maximum Deflections .
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+Lr+H 1 0.3197 9.502 0.0000 0.000
2 0.0000 9.502 +D+Lr+H -0.0302 0.670
.
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2 Support 3
Overall MAXimum 3.675 1.670
Overall MINimum 0.848 0.386
+D+H 1.414 0.643
+D+L+H 1.414 0.643
+D+Lr+H 3.675 1.670
+D+S+H 1.414 0.643
+D+0.750Lr+0.750L+H 3.110 1.413
+D+0.750L+0.750S+H 1.414 0.643
+D+0.60W+H 1.414 0.643
+D+0.70E+H 1.414 0.643
+D+0.750Lr+0.750L+0.450W+H 3.110 1.413
+D+0.750L+0.750S+0.450W+H 1.414 0.643
+D+0.750L+0.750S+0.5250E+H 1.414 0.643
+0.60D+0.60W+0.60H 0.848 0.386
+0.60D+0.70E+0.60H 0.848 0.386
D Only 1.414 0.643
Lr Only 2.261 1.027
L Only
S Only
W Only
E Only
H Only

29 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT3

General Beam Properties


Elastic Modulus 29,000.0 ksi
Span #1 Span Length = 22.0 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4
Span #2 Span Length = 0.670 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Loads on all spans...
Uniform Load on ALL spans : D = 0.1375, Lr = 0.220 k/ft, Tributary Width = 1.0 ft

DESIGN SUMMARY .
Maximum Bending = 31.220 k-ft Maximum Shear = 5.692 k
Load Combination +1.20D+1.60Lr+0.50L+1.60H Load Combination +1.20D+1.60Lr+0.50L+1.60H
Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1
Location of maximum on span 11.000 ft Location of maximum on span 22.000 ft
Maximum Deflection
Max Downward Transient Deflection 0.404 in 653
Max Upward Transient Deflection -0.039 in 414
Max Downward Total Deflection 0.656 in 402
Max Upward Total Deflection -0.063 in 254

Maximum Forces & Stresses for Load Combinations .


Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Overall MAXimum Envelope
Dsgn. L = 22.00 ft 1 31.22 -0.12 31.22 5.69
Dsgn. L = 0.67 ft 2 -0.12 0.12 0.35
+1.40D+1.60H
Dsgn. L = 22.00 ft 1 11.62 -0.04 11.62 2.12
Dsgn. L = 0.67 ft 2 -0.04 0.04 0.13
+1.20D+0.50Lr+1.60L+1.60H
Dsgn. L = 22.00 ft 1 16.61 -0.06 16.61 3.03
Dsgn. L = 0.67 ft 2 -0.06 0.06 0.18
+1.20D+1.60L+0.50S+1.60H
Dsgn. L = 22.00 ft 1 9.96 -0.04 9.96 1.82
Dsgn. L = 0.67 ft 2 -0.04 0.04 0.11
+1.20D+1.60Lr+0.50L+1.60H
Dsgn. L = 22.00 ft 1 31.22 -0.12 31.22 5.69
Dsgn. L = 0.67 ft 2 -0.12 0.12 0.35
+1.20D+1.60Lr+0.50W+1.60H
Dsgn. L = 22.00 ft 1 31.22 -0.12 31.22 5.69
Dsgn. L = 0.67 ft 2 -0.12 0.12 0.35
+1.20D+0.50L+1.60S+1.60H
Dsgn. L = 22.00 ft 1 9.96 -0.04 9.96 1.82
Dsgn. L = 0.67 ft 2 -0.04 0.04 0.11
+1.20D+1.60S+0.50W+1.60H
Dsgn. L = 22.00 ft 1 9.96 -0.04 9.96 1.82
Dsgn. L = 0.67 ft 2 -0.04 0.04 0.11
+1.20D+0.50Lr+0.50L+W+1.60H
Dsgn. L = 22.00 ft 1 16.61 -0.06 16.61 3.03
Dsgn. L = 0.67 ft 2 -0.06 0.06 0.18
+1.20D+0.50L+0.50S+W+1.60H
Dsgn. L = 22.00 ft 1 9.96 -0.04 9.96 1.82
Dsgn. L = 0.67 ft 2 -0.04 0.04 0.11 30 of 209
+1.20D+0.50L+0.20S+E+1.60H
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT3

Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Dsgn. L = 22.00 ft 1 9.96 -0.04 9.96 1.82
Dsgn. L = 0.67 ft 2 -0.04 0.04 0.11
+0.90D+W+0.90H
Dsgn. L = 22.00 ft 1 7.47 -0.03 7.47 1.36
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+0.90D+E+0.90H
Dsgn. L = 22.00 ft 1 7.47 -0.03 7.47 1.36
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
Overall Maximum Deflections .
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+Lr+H 1 0.6563 11.000 0.0000 0.000
2 0.0000 11.000 +D+Lr+H -0.0631 0.670
.
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2 Support 3
Overall MAXimum 3.929 4.176
Overall MINimum 0.907 0.964
+D+H 1.511 1.606
+D+L+H 1.511 1.606
+D+Lr+H 3.929 4.176
+D+S+H 1.511 1.606
+D+0.750Lr+0.750L+H 3.324 3.533
+D+0.750L+0.750S+H 1.511 1.606
+D+0.60W+H 1.511 1.606
+D+0.70E+H 1.511 1.606
+D+0.750Lr+0.750L+0.450W+H 3.324 3.533
+D+0.750L+0.750S+0.450W+H 1.511 1.606
+D+0.750L+0.750S+0.5250E+H 1.511 1.606
+0.60D+0.60W+0.60H 0.907 0.964
+0.60D+0.70E+0.60H 0.907 0.964
D Only 1.511 1.606
Lr Only 2.418 2.570
L Only
S Only
W Only
E Only
H Only

31 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

GT4 Girder Truss ‐ Only Reactions Use: -

GT3
D1
D2
Z

X D1 D2
Y 12.3 2.7
10.8 20.2 20.9
Units = ft
Roof        
BEAM SUPP DL Lr LL E Units DL1 = 12,5psf *12,3ft = 154,1 Lbs/ft
GT3 1 1510 2420 0 0 [Lbs] Lr1 = 20psf *12,3ft = 246,6 Lbs/ft
Roof        
DL2 = 12,5psf *2,7ft = 33,4 Lbs/ft
Lr2 = 20psf *2,7ft = 53,4 Lbs/ft
1

32 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT4

General Beam Properties


Elastic Modulus 29,000.0 ksi
Span #1 Span Length = 20.250 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4
Span #2 Span Length = 0.670 ft Area = 10.0 in^2 Moment of Inertia = 100.0 in^4

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Load for Span Number 1
Uniform Load : D = 0.1541, Lr = 0.2466 k/ft, Extent = 0.0 -->> 10.830 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.03340, Lr = 0.05340 k/ft, Extent = 10.830 -->> 20.250 ft, Tributary Width = 1.0 ft

Point Load : D = 1.510, Lr = 2.420 k @ 10.830 ft

Load for Span Number 2


Uniform Load : D = 0.03340, Lr = 0.05340 k/ft, Tributary Width = 1.0 ft

DESIGN SUMMARY .
Maximum Bending = 47.304 k-ft Maximum Shear = 7.515 k
Load Combination +1.20D+1.60Lr+0.50L+1.60H Load Combination +1.20D+1.60Lr+0.50L+1.60H
Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1
Location of maximum on span 10.748 ft Location of maximum on span 0.000 ft
Maximum Deflection
Max Downward Transient Deflection 0.463 in 525
Max Upward Transient Deflection -0.046 in 352
Max Downward Total Deflection 0.752 in 323
Max Upward Total Deflection -0.074 in 216

Maximum Forces & Stresses for Load Combinations .


Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
Overall MAXimum Envelope
Dsgn. L = 20.25 ft 1 47.30 -0.03 47.30 7.52
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+1.40D+1.60H
Dsgn. L = 20.25 ft 1 17.60 -0.01 17.60 2.80
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+0.50Lr+1.60L+1.60H
Dsgn. L = 20.25 ft 1 25.15 -0.01 25.15 4.00
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.04
+1.20D+1.60L+0.50S+1.60H
Dsgn. L = 20.25 ft 1 15.09 -0.01 15.09 2.40
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+1.60Lr+0.50L+1.60H
Dsgn. L = 20.25 ft 1 47.30 -0.03 47.30 7.52
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+1.20D+1.60Lr+0.50W+1.60H
Dsgn. L = 20.25 ft 1 47.30 -0.03 47.30 7.52
Dsgn. L = 0.67 ft 2 -0.03 0.03 0.08
+1.20D+0.50L+1.60S+1.60H
Dsgn. L = 20.25 ft 1 15.09 -0.01 15.09 2.40 33 of 209
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Beam Analysis ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : GT4

Load Combination Max Stress Ratios Summary of Moment Values (k-ft) Shear Values (k)
Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega
+1.20D+1.60S+0.50W+1.60H
Dsgn. L = 20.25 ft 1 15.09 -0.01 15.09 2.40
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+0.50Lr+0.50L+W+1.60H
Dsgn. L = 20.25 ft 1 25.15 -0.01 25.15 4.00
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.04
+1.20D+0.50L+0.50S+W+1.60H
Dsgn. L = 20.25 ft 1 15.09 -0.01 15.09 2.40
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+1.20D+0.50L+0.20S+E+1.60H
Dsgn. L = 20.25 ft 1 15.09 -0.01 15.09 2.40
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.03
+0.90D+W+0.90H
Dsgn. L = 20.25 ft 1 11.32 -0.01 11.32 1.80
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.02
+0.90D+E+0.90H
Dsgn. L = 20.25 ft 1 11.32 -0.01 11.32 1.80
Dsgn. L = 0.67 ft 2 -0.01 0.01 0.02
Overall Maximum Deflections .
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+Lr+H 1 0.7518 10.125 0.0000 0.000
2 0.0000 10.125 +D+Lr+H -0.0741 0.670
.
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2 Support 3
Overall MAXimum 5.197 3.949
Overall MINimum 1.199 0.911
+D+H 1.998 1.518
+D+L+H 1.998 1.518
+D+Lr+H 5.197 3.949
+D+S+H 1.998 1.518
+D+0.750Lr+0.750L+H 4.397 3.341
+D+0.750L+0.750S+H 1.998 1.518
+D+0.60W+H 1.998 1.518
+D+0.70E+H 1.998 1.518
+D+0.750Lr+0.750L+0.450W+H 4.397 3.341
+D+0.750L+0.750S+0.450W+H 1.998 1.518
+D+0.750L+0.750S+0.5250E+H 1.998 1.518
+0.60D+0.60W+0.60H 1.199 0.911
+0.60D+0.70E+0.60H 1.199 0.911
D Only 1.998 1.518
Lr Only 3.199 2.431
L Only
S Only
W Only
E Only
H Only

34 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

TJ1 Trellis Joist Use: 3x6 D.F.#2

D1
Z

X D1
Y 0.8
9.510.0
10.0
Units = ft
       Trellis
DL1 = 5psf *0,8ft = 3,8 Lbs/ft
Lr1 = 10psf *0,8ft = 7,5 Lbs/ft
1

35 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : TJ1
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 3x6, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875 psi Fc - Prll 600 psi Fv 170 psi Ebend- xx 1300 ksi Density 31.2 pcf
Fb - Compr 875 psi Fc - Perp 625 psi Ft 425 psi Eminbend - xx 470 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.00380, Lr = 0.00750 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.112 : 1
fb : Actual : 152.52 psi at 4.750 ft in Span # 1
Fb : Allowable : 1,366.58 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.032 : 1
fv : Actual : 6.75 psi at 9.073 ft in Span # 1
Fv : Allowable : 212.50 psi
Load Comb : +D+Lr+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.031 in Total Downward 0.058 in
Left Support 0.03 0.04 Ratio 3732 >360 Ratio 1960 >240
Right Support 0.04 0.04
LC: Lr Only LC: +D+Lr+H
Transient Upward -0.005 in Total Upward -0.010 in
Ratio 2362 Ratio 1240
LC: Lr Only LC: +D+Lr+H

36 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

DBM101 Drop Beam Use: 4x12 D.F.#2

D1
Z

X D1
Y 5.3
18.0
Units = ft
       Trellis
DL1 = 5psf *5,3ft = 26,7 Lbs/ft
Lr1 = 10psf *5,3ft = 53,3 Lbs/ft
1
DBM102 Drop Beam Use: 4x12 D.F.#2

D1
Z

X
D1
Y
9.5 1.3
Units = ft
       Trellis
DL1 = 5psf *1,3ft = 6,7 Lbs/ft
Lr1 = 10psf *1,3ft = 13,3 Lbs/ft
1

37 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : DBM101
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 4x12, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.02670, Lr = 0.05330 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.540 : 1
fb : Actual : 582.79 psi at 9.000 ft in Span # 1
Fb : Allowable : 1,078.51 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.129 : 1
fv : Actual : 27.32 psi at 0.000 ft in Span # 1
Fv : Allowable : 212.50 psi
Load Comb : +D+Lr+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.234 in Total Downward 0.389 in
Left Support 0.32 0.48 Ratio 921 >360 Ratio 554 >240
Right Support 0.32 0.48
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : DBM101
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 4x12, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.00670, Lr = 0.01330 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.045 : 1
fb : Actual : 52.32 psi at 4.750 ft in Span # 1
Fb : Allowable : 1,161.85 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.020 : 1
fv : Actual : 4.16 psi at 0.000 ft in Span # 1
Fv : Allowable : 212.50 psi
Load Comb : +D+Lr+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.005 in Total Downward 0.010 in
Left Support 0.07 0.06 Ratio 9999 >360 Ratio 9999 >240
Right Support 0.07 0.06
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

38 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

HDR101 Header Beam Use: 6x6 D.F.#2


8.6
D1
Z 2.0

X D1
Y
4.4
Units = ft
Roof    Wall Ext.    
DL1 = 12,5psf *8,6ft+18,5psf *2ft = 144,3 Lbs/ft
Lr1 = 20psf *8,6ft = 171,6 Lbs/ft
1
HDR102 Header Beam Use: 5 1/4" x 7" PSL2.2
1.3 17.0
GT1
D1
D2
Z
2.0 2.0
X
D1 D2
Y
1.3 2.6 1.3
Units = ft
Roof    Wall Ext.    Ceiling
BEAM SUPP. DL Lr  LL  E Units DL1 = 12,5psf *1,3ft+18,5psf *2ft+6psf *1,3ft = 61,6 Lbs/ft
GT1 1 1360 2170 0 0 [Lbs] Lr1 = 20psf *1,3ft+10psf *1,3ft = 39,9 Lbs/ft
Roof    Wall Ext.    
DL2 = 12,5psf *17ft+18,5psf *2ft = 249,5 Lbs/ft
Lr2 = 20psf *17ft = 340 Lbs/ft
1
HDR103 Header Beam Use: 5 1/4" x 7" PSL2.2
8.6 12.8
GT2
D1
D2
Z 2.0 2.0

X D1 D2
Y
2.0 4.5
Units = ft
Roof    Wall Ext.    
BEAM SUPP. DL Lr  LL E  Units DL1 = 12,5psf *8,6ft+18,5psf *2ft = 144,3 Lbs/ft
GT2 2 640 1030 0 0 [Lbs] Lr1 = 20psf *8,6ft = 171,6 Lbs/ft
Roof    Wall Ext.    
DL2 = 12,5psf *12,8ft+18,5psf *2ft = 197,4 Lbs/ft
Lr2 = 20psf *12,8ft = 256,6 Lbs/ft
1

39 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : HDR101
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1443, Lr = 0.1716 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.255 : 1
fb : Actual : 481.47 psi at 2.210 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.108 : 1
fv : Actual : 39.61 psi at 3.963 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.015 in Total Downward 0.028 in
Left Support 0.33 0.38 Ratio 3549 >360 Ratio 1888 >240
Right Support 0.33 0.38
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : HDR102
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x7.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.06290, Lr = 0.03990 k/ft, Trib= 1.0 ft
Point: D = 1.360, Lr = 2.170 k @ 1.250 ft
Design Summary .
Max fb/Fb Ratio = 0.148 : 1
fb : Actual : 926.31 psi at 1.250 ft in Span # 1
Fb : Allowable : 6,248.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.173 : 1
fv : Actual : 108.38 psi at 1.925 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.004 in Total Downward 0.006 in
Left Support 0.77 1.13 Ratio 7848 >360 Ratio 4724 >240
Right Support 0.77 1.13
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

40 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : HDR103


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x7.0, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2900 psi Fc - Prll 2900 psi Fv 290 psi Ebend- xx 2200 ksi Density 45.05 pcf
Fb - Compr 2900 psi Fc - Perp 625 psi Ft 2025 psi Eminbend - xx 1118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1443, Lr = 0.1716 k/ft, 0.0 ft to 2.0 ft, Trib= 1.0 ft
Unif Load: D = 0.1974, Lr = 0.2566 k/ft, 2.0 to 4.50 ft, Trib= 1.0 ft
Point: D = 0.640, Lr = 1.030 k @ 2.0 ft
Design Summary .
Max fb/Fb Ratio = 0.222 : 1
fb : Actual : 800.56 psi at 1.995 ft in Span # 1
Fb : Allowable : 3,610.47 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.177 : 1
fv : Actual : 64.23 psi at 0.000 ft in Span # 1
Fv : Allowable : 362.50 psi
Load Comb : +D+Lr+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.016 in Total Downward 0.028 in
Left Support 0.74 1.02 Ratio 3305 >360 Ratio 1937 >240
Right Support 0.73 1.00
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

41 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

HDR104 Header Beam Use: 5 1/4" x 7" PSL2.2


12.8
D1
Z 2.0

X D1
Y
10.7
Units = ft
Roof    Wall Ext.    
DL1 = 12,5psf *12,8ft+18,5psf *2ft = 197,4 Lbs/ft
Lr1 = 20psf *12,8ft = 256,6 Lbs/ft
1
HDR105 Header Beam Use: 5 1/4" x 9 1/4" PSL2.2
1.3 11.8
GT3
D1
D2
Z
2.0 2.0
X
D1 D2
Y
3.3 10.8
Units = ft
Roof    Wall Ext.    
BEAM SUPP. DL Lr  LL  E Units DL1 = 12,5psf *1,3ft+18,5psf *2ft = 53,6 Lbs/ft
GT3 2 1610 2570 0 0 [Lbs] Lr1 = 20psf *1,3ft = 26,6 Lbs/ft
Roof    Wall Ext.    
DL2 = 12,5psf *11,8ft+18,5psf *2ft = 183,9 Lbs/ft
Lr2 = 20psf *11,8ft = 235 Lbs/ft
1
HDR106 Header Beam Use: 6x6 D.F.#2
7.6

D1
Z 2.0

X D1
Y
4.5
Units = ft
Roof    Wall Ext.    
DL1 = 12,5psf *7,6ft+18,5psf *2ft = 131,8 Lbs/ft
Lr1 = 20psf *7,6ft = 151,6 Lbs/ft
1

42 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : HDR104
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x7.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1974, Lr = 0.2566 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.425 : 1
fb : Actual : 2,633.74 psi at 5.335 ft in Span # 1
Fb : Allowable : 6,194.10 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.205 : 1
fv : Actual : 128.63 psi at 10.101 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.228 in Total Downward 0.413 in
Left Support 1.11 1.37 Ratio 561 >360 Ratio 309 >240
Right Support 1.11 1.37
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : HDR105
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x9.25, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.05360, Lr = 0.02660 k/ft, 0.0 ft to 3.330 ft, Trib= 1.0 ft
Unif Load: D = 0.1839, Lr = 0.2350 k/ft, 3.330 to 10.830 ft, Trib= 1.0 ft
Point: D = 1.610, Lr = 2.570 k @ 3.330 ft
Design Summary .
Max fb/Fb Ratio = 0.513 : 1
fb : Actual : 3,161.91 psi at 3.357 ft in Span # 1
Fb : Allowable : 6,163.34 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.298 : 1
fv : Actual : 186.57 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.204 in Total Downward 0.352 in
Left Support 1.83 2.47 Ratio 638 >360 Ratio 368 >240
Right Support 1.51 1.96
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

43 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : HDR106


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1318, Lr = 0.1516 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.237 : 1
fb : Actual : 447.57 psi at 2.250 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.099 : 1
fv : Actual : 36.47 psi at 0.000 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.014 in Total Downward 0.027 in
Left Support 0.31 0.34 Ratio 3806 >360 Ratio 1990 >240
Right Support 0.31 0.34
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

44 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

HBM201 Hip Beam Use: 4x10 D.F.#2

T1 3.0
Z
0.0
X 0.0

Y 3.0
2.5 9.5
Units = ft
Lower Roof
DL1 Max = 63Lbs/ft          DL1 Min = 0Lbs/ft
Lr1 Max = 120Lbs/ft          Lr1 Min = 0Lbs/ft
1
HBM202 Hip Beam Use: 4x10 D.F.#2

2.7
Z T1

X
Y
6.6 9.2 2.3
Units = ft
Lower Roof
DL1 Max = 52,5Lbs/ft          DL1 Min = 0Lbs/ft
Lr1 Max = 100Lbs/ft          Lr1 Min = 0Lbs/ft
1

45 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : HBM201
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 4x10, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D= 0.0->0.0630, Lr = 0.0->0.120 k/ft, -2.50 to 7.0 ft
Design Summary .
Max fb/Fb Ratio = 0.114 : 1
fb : Actual : 252.72 psi at 3.885 ft in Span # 2
Fb : Allowable : 2,214.57 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.065 : 1
fv : Actual : 23.98 psi at 6.230 ft in Span # 2
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.013 in Total Downward 0.021 in
Left Support 0.18 0.26 Ratio 6375 >360 Ratio 4004 >240
Right Support 0.19 0.31
LC: Lr Only LC: +D+Lr+H
Transient Upward -0.014 in Total Upward -0.021 in
Ratio 4396 Ratio 2814
LC: Lr Only LC: +D+Lr+H
Wood Beam Design : HBM202
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 4x10, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875 psi Fc - Prll 600 psi Fv 170 psi Ebend- xx 1300 ksi Density 31.2 pcf
Fb - Compr 875 psi Fc - Perp 625 psi Ft 425 psi Eminbend - xx 470 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D= 0.05250->0.0, Lr = 0.10->0.0 k/ft, 0.0 to 9.250 ft
Design Summary .
Max fb/Fb Ratio = 0.087 : 1
fb : Actual : 192.99 psi at 2.968 ft in Span # 1
Fb : Allowable : 2,217.45 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.054 : 1
fv : Actual : 19.87 psi at 6.670 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.009 in Total Downward 0.015 in
Left Support 0.15 0.25 Ratio 8815 >360 Ratio 5511 >240
Right Support 0.16 0.21
LC: Lr Only LC: +D+Lr+H
Transient Upward -0.010 in Total Upward -0.016 in
Ratio 6162 Ratio 3964
LC: Lr Only LC: +D+Lr+H

46 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM201 Flush Beam Use: 5 1/4" x 14" PSL2.2


9.0
P2 HDR101
D1
D2
Z D3
9.0

X D1 D2 D3
Y 3.0 7.5 3.0 7.5 3.0 7.5
4.4 15.2 19.3 20.7 24.1 28.5
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  Lower Roof
BEAM SUPP DL Lr LL E Units DL1 = 30psf *7,5ft+10,5psf *3ft = 256,5 Lbs/ft
P2 Lr1 = 20psf *3ft = 60 Lbs/ft
HDR101 2 330 380 0 0 [Lbs] LL1 = 40psf *7,5ft = 300 Lbs/ft
E‐Line C(R)  ‐ 0 0 0 ‐2440 [Lbs] Roof    Wall Ext.  Floor  Lower Roof
P2 DL2 = 12,5psf *9ft+18,5psf *9ft+30psf *7,5ft+10,5psf *3ft = 535,5 Lbs/ft
HDR101 1 330 380 0 0 [Lbs] Lr2 = 20psf *9ft+20psf *3ft = 240 Lbs/ft
E‐Line C(R)  ‐ 0 0 0 2440 [Lbs] LL2 = 40psf *7,5ft = 300 Lbs/ft
     Floor  Lower Roof
DL3 = 30psf *7,5ft+10,5psf *3ft = 256,5 Lbs/ft
Lr3 = 20psf *3ft = 60 Lbs/ft
LL3 = 40psf *7,5ft = 300 Lbs/ft
1
FBM202 Flush Beam Use: 5 1/4" x 14" PSL2.2
9.8 9.8
P1 P2 P3
D1
D2 D3
Z D4 9.0 9.0
X
D1 D2 D3 D4
Y 1.3
4.6 7.0 13.0 17.5 2.5 2.5 1.3 2.5 1.3 2.5 1.3
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5 Roof    Wall Ext.  Floor  Lower Roof
BEAM SUPP. DL Lr  LL  E Units DL1 = 12,5psf *9,8ft+18,5psf *9ft+30psf *1,3ft+10,5psf *2,5ft = 355,5 Lbs/ft
P1 Lr1 = 20psf *9,8ft+20psf *2,5ft = 246,6 Lbs/ft
HDR102 1 770 1130 0 0 [Lbs] LL1 = 40psf *1,3ft = 53,2 Lbs/ft
E‐Line 1(R)  ‐ 0 0 0 1790 [Lbs]      Floor  Lower Roof
P2 DL2 = 30psf *1,3ft+10,5psf *2,5ft = 66,2 Lbs/ft
HDR102 2 770 1130 0 0 [Lbs] Lr2 = 20psf *2,5ft = 50 Lbs/ft
E‐Line 1(R)  ‐ 0 0 0 ‐1790 [Lbs] LL2 = 40psf *1,3ft = 53,2 Lbs/ft
P3 Roof    Wall Ext.  Floor  Lower Roof
HDR101 1 330 380 0 0 [Lbs] DL3 = 12,5psf *9,8ft+18,5psf *9ft+30psf *1,3ft+10,5psf *2,5ft = 355,5 Lbs/ft
E‐Line 1(R)  ‐ 0 0 0 1790 [Lbs] Lr3 = 20psf *9,8ft+20psf *2,5ft = 246,6 Lbs/ft
LL3 = 40psf *1,3ft = 53,2 Lbs/ft
     Floor  Lower Roof
DL4 = 30psf *1,3ft+10,5psf *2,5ft = 66,2 Lbs/ft
Lr4 = 20psf *2,5ft = 50 Lbs/ft
1 LL4 = 40psf *1,3ft = 53,2 Lbs/ft
FBM203 Flush Beam Use: 3 1/2" x 14" PSL2.2

FBM FBM 1.3


D1 1.3
D2 D3
Z 9.0 9.0

X D1 D2 D3
Y 2.7 1.3 1.7
4.0 9.5 17.8
Units = ft
     Floor  
BEAM SUPP. DL Lr  LL E  Units DL1 = 30psf *2,7ft = 80,1 Lbs/ft
FBM 1 400 470 0 0 [Lbs] LL1 = 40psf *2,7ft =106,8 Lbs/ft
FBM 1 400 470 0 0 [Lbs]
Roof    Wall Ext.  Floor  
DL2 = 12,5psf *1,3ft+18,5psf *9ft+30psf *1,3ft = 223 Lbs/ft
Lr2 = 20psf *1,3ft = 26,6 Lbs/ft
LL2 = 40psf *1,3ft = 53,2 Lbs/ft
Roof    Wall Ext.  Floor  
DL3 = 12,5psf *1,3ft+18,5psf *9ft+30psf *1,7ft = 233,2 Lbs/ft
Lr3 = 20psf *1,3ft = 26,6 Lbs/ft
LL3 = 40psf *1,7ft = 66,8 Lbs/ft
1

47 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Wood Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM201

CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set :
Material Properties
Analysis Method : Load Resistance Factor D Fb + 2,900.0 psi E : Modulus of Elasticity
Load Combination : Fb - 2,900.0 psi Ebend- xx 2,200.0 ksi
Fc - Prll 2,900.0 psi Eminbend - xx 1,118.19 ksi
Wood Species : Trus Joist Fc - Perp 625.0 psi
Wood Grade : Parallam PSL 2.2E Fv 290.0 psi
Ft 2,025.0 psi Density 45.050 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Beam self weight calculated and added to loads
Load for Span Number 1
Point Load : D = 0.330, Lr = 0.380, E = -2.440 k @ 4.420 ft

Uniform Load : D = 0.2565, Lr = 0.060, L = 0.30 k/ft, Extent = 0.0 -->> 4.420 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.5355, Lr = 0.240, L = 0.30 k/ft, Extent = 4.420 -->> 20.750 ft, Tributary Width = 1.0 ft

Point Load : D = 0.330, Lr = 0.380, E = 2.440 k @ 19.330 ft

Load for Span Number 2


Uniform Load : D = 0.5355, Lr = 0.240, L = 0.30 k/ft, Extent = 0.0 -->> 3.420 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.2565, Lr = 0.060, L = 0.30 k/ft, Extent = 3.420 -->> 7.840 ft, Tributary Width = 1.0 ft

48 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Wood Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM201

DESIGN SUMMARY Design OK


Maximum Bending Stress Ratio = 0.736: 1 Maximum Shear Stress Ratio = 0.598 : 1
Section used for this span 5.25x14.0 Section used for this span 5.25x14.0
fb : Actual = 3,623.26psi fv : Actual = 299.43 psi
FB : Allowable = 4,926.18psi Fv : Allowable = 501.12 psi
Load Combination +1.20D+0.50Lr+1.60L+1.60H Load Combination +1.20D+0.50Lr+1.60L+1.60H
Location of maximum on span = 20.750 ft Location of maximum on span = 19.591 ft
Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1
Maximum Deflection
Max Downward Transient Deflection 0.263 in Ratio = 948 >=360
Max Upward Transient Deflection -0.106 in Ratio = 2358 >=360
Max Downward Total Deflection 0.840 in Ratio = 296 >=240
Max Upward Total Deflection 0.000 in Ratio = 0 <240

Overall Maximum Deflections .


Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+0.750Lr+0.750L+0.450W+H 1 0.8398 9.506 0.0000 0.000
2 0.0000 9.506 +D+0.750Lr+0.750L+0.450W+H -0.0802 3.154

49 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM202
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3555, Lr = 0.2466, L = 0.05320 k/ft, 0.0 ft to 4.580 ft, Trib= 1.0 ft
Unif Load: D = 0.06620, Lr = 0.050, L = 0.05320 k/ft, 4.580 to 7.0 ft, Trib= 1.0 ft
Unif Load: D = 0.3555, Lr = 0.2466, L = 0.05320 k/ft, 7.0 to 13.0 ft, Trib= 1.0 ft
Unif Load: D = 0.06620, Lr = 0.050, L = 0.05320 k/ft, 13.0 to 17.50 ft, Trib= 1.0 ft
Point: D = 0.450, Lr = 0.630, E = 1.790 k @ 4.580 ft
Point: D = 1.080, Lr = 1.640, E = -1.790 k @ 7.0 ft
Point: D = 0.330, Lr = 0.380, E = 1.790 k @ 13.0 ft
Design Summary .
Max fb/Fb Ratio = 0.562 : 1
fb : Actual : 3,250.23 psi at 7.000 ft in Span # 1
Fb : Allowable : 5,783.68 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.291 : 1
fv : Actual : 182.38 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.311 in Total Downward 0.653 in
Left Support 3.74 0.47 3.27 0.71 Ratio 674 >360 Ratio 321 >240
Right Support 2.74 0.47 2.33 1.08
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : FBM203
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 3.5x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.08010, L = 0.1068 k/ft, 0.0 ft to 4.0 ft, Trib= 1.0 ft
Unif Load: D = 0.2230, Lr = 0.02660, L = 0.05320 k/ft, 4.0 to 9.50 ft, Trib= 1.0 ft
Unif Load: D = 0.2332, Lr = 0.02660, L = 0.06680 k/ft, 9.50 to 17.750 ft, Trib= 1.0 ft
Point: D = 0.40, L = 0.470 k @ 4.0 ft
Point: D = 0.40, L = 0.470 k @ 9.50 ft
Design Summary .
Max fb/Fb Ratio = 0.591 : 1
fb : Actual : 2,418.20 psi at 9.467 ft in Span # 1
Fb : Allowable : 4,089.38 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.212 : 1
fv : Actual : 132.60 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.171 in Total Downward 0.534 in
Left Support 2.12 1.27 0.14 Ratio 1242 >360 Ratio 398 >240
Right Support 2.42 0.94 0.22
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

50 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM204 Flush Beam Use: 5 1/4" x 14" PSL2.2

FBM203
D1
Z

X D1
Y 9.6
5.8 7.9
Units = ft
     Floor  
BEAM SUPP DL Lr LL E Units DL1 = 30psf *9.6ft = 287.4 Lbs/ft
FBM203 1 2120 140 1270 0 [Lbs] LL1 = 40psf *9.6ft =383.2 Lbs/ft
1
FBM205 Flush Beam Use: 5 1/4" x 14" PSL2.2
12.8
P1
D1
D2
Z
9.0
X
D1 D2
Y 8.8
1.9 9.3 3.8 8.8 8.8
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  Lower Roof
BEAM SUPP. DL Lr  LL  E Units DL1 = 30psf *8.8ft+10.5psf *3.8ft = 304.3 Lbs/ft
P1 Lr1 = 20psf *3.8ft = 75 Lbs/ft
HDR103 2 730 1000 0 0 [Lbs] LL1 = 40psf *8.8ft = 353.2 Lbs/ft
E‐Line A(R)  ‐ 0 0 0 3229 [Lbs] Roof    Wall Ext.  Floor  Lower Roof
DL2 = 12.5psf *12.8ft+18.5psf *9ft+30psf *8.8ft+10.5psf *8.8ft = 683.7 Lbs/ft
Lr2 = 20psf *12,8ft+20psf *8.8ft = 431.6 Lbs/ft
LL2 = 40psf *8.8ft = 353.2 Lbs/ft
1
FBM206 Flush Beam Use: 5 1/4" x 14" PSL2.2
12.8 12.8 12.8
P1
D1
D2 D3
Z D4 9.0 9.0 9.0

X D1 D2 D3 D4
10.7
Y 1.3
2.5 9.5 11.9 18.9 21.6
Units = ft
     Floor  
BEAM SUPP. DL Lr  LL E  Units DL1 = 30psf *1.3ft = 39.9 Lbs/ft
P1 LL1 = 40psf *1,3ft =53.2 Lbs/ft
HDR104 1 1110 1370 0 0 [Lbs]
HDR104 2 1110 1370 0 0 [Lbs] Roof    Wall Ext.    
DL2 = 12.5psf *12.8ft+18.5psf *9ft = 326.9 Lbs/ft
Lr2 = 20psf *12,8ft = 256.6 Lbs/ft
Roof    Wall Ext.    
DL3 = 12.5psf *12.8ft+18.5psf *9ft = 326.9 Lbs/ft
Lr3 = 20psf *12,8ft = 256.6 Lbs/ft
Roof    Wall Ext.    
DL4 = 12.5psf *12.8ft+18.5psf *9ft = 326.9 Lbs/ft
Lr4 = 20psf *12,8ft = 256.6 Lbs/ft
1

51 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM204
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.2874, Lr = 0.3832 k/ft, Trib= 1.0 ft
Point: D = 2.120, Lr = 0.140, L = 1.270 k @ 5.750 ft
Design Summary .
Max fb/Fb Ratio = 0.133 : 1
fb : Actual : 805.15 psi at 4.829 ft in Span # 1
Fb : Allowable : 6,031.76 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.170 : 1
fv : Actual : 106.65 psi at 6.682 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.013 in Total Downward 0.034 in
Left Support 1.78 0.34 1.54 Ratio 7227 >360 Ratio 2729 >240
Right Support 2.77 0.93 1.60
LC: Lr Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : FBM205
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3043, Lr = 0.0750, L = 0.3532 k/ft, 0.0 ft to 1.90 ft, Trib= 1.0 ft
Unif Load: D = 0.6837, Lr = 0.4316, L = 0.3532 k/ft, 1.90 to 9.30 ft, Trib= 1.0 ft
Point: D = 0.730, Lr = 1.0, E = 3.229 k @ 1.90 ft
Design Summary .
Max fb/Fb Ratio = 0.265 : 1
fb : Actual : 1,591.44 psi at 3.224 ft in Span # 1
Fb : Allowable : 6,003.62 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.367 : 1
fv : Actual : 230.18 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.032 in Total Downward 0.088 in
Left Support 3.22 1.64 2.19 2.57 Ratio 3507 >360 Ratio 1262 >240
Right Support 3.36 1.64 2.14 0.66
LC: Lr Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

52 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : FBM206


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3668, Lr = 0.2566, L = 0.05320 k/ft, 0.0 ft to 2.50 ft, Trib= 1.0 ft
Unif Load: D = 0.03990, L = 0.05320 k/ft, 2.50 to 9.50 ft, Trib= 1.0 ft
Unif Load: D = 0.3668, Lr = 0.2566, L = 0.05320 k/ft, 9.50 to 11.90 ft, Trib= 1.0 ft
Unif Load: D = 0.03990, L = 0.05320 k/ft, 11.90 to 18.90 ft, Trib= 1.0 ft
Point: D = 2.220, Lr = 2.740 k @ 10.70 ft
Unif Load: D = 0.3668, Lr = 0.2566, L = 0.05320 k/ft, 18.90 to 21.60 ft
Design Summary .
Max fb/Fb Ratio = 0.707 : 1
fb : Actual : 3,950.05 psi at 10.728 ft in Span # 1
Fb : Allowable : 5,585.07 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.217 : 1
fv : Actual : 135.80 psi at 20.448 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.496 in Total Downward 1.069 in
Left Support 3.02 0.57 2.34 Ratio 522 >360 Ratio 242 >240
Right Support 3.04 0.57 2.35
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

53 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM207 Flush Beam Use: 5 1/4" x 14" PSL2.2

D1
Z

X D1
Y 10.0
6.4
Units = ft
     Floor  
DL1 = 30psf *10ft = 300 Lbs/ft
LL1 = 40psf *10ft =400 Lbs/ft
1
FBM208 Flush Beam Use: 5 1/4" x 14" PSL2.2

D1
Z

X
D1
Y 5.0
9.4
Units = ft
     Floor  
DL1 = 30psf *5ft = 150 Lbs/ft
LL1 = 40psf *5ft =200 Lbs/ft
1
FBM209 Flush Beam Use: 5 1/4" x 14" PSL2.2
1.3 13.8
P1 P2 P3
D1
D2 D3
Z 9.0 9.0

X D1 D2 D3
Y 11.0 11.0 11.0
3.2 8.3 11.0 12.5
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  
BEAM SUPP. DL Lr  LL E 
Units DL1 = 30psf *11ft = 330 Lbs/ft
P1 LL1 = 40psf *11ft =440 Lbs/ft
E‐Line 4(R)  ‐ 0 0 0 ‐5316 [Lbs]
P2 Roof    Wall Ext.  Floor  
GT3 1 1510 2420 0 0 [Lbs] DL2 = 12.5psf *1.3ft+18.5psf *9ft+30psf *11ft = 513.1 Lbs/ft
P3 Lr2 = 20psf *1,3ft = 26.6 Lbs/ft
HDR104 2 1110 1370 0 0 [Lbs] LL2 = 40psf *11ft = 440 Lbs/ft
FBM206 2 3040 2350 570 0 [Lbs] Roof    Wall Ext.  Floor  
E‐Line 4(R)  ‐ 0 0 0 5316 [Lbs] DL3 = 12.5psf *13.8ft+18.5psf *9ft+30psf *11ft = 668.4 Lbs/ft
Lr3 = 20psf *13,8ft = 275 Lbs/ft
LL3 = 40psf *11ft = 440 Lbs/ft
1

54 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM207
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.30, L = 0.40 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.061 : 1
fb : Actual : 368.14 psi at 3.200 ft in Span # 1
Fb : Allowable : 6,060.98 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.069 : 1
fv : Actual : 42.95 psi at 5.248 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.006 in Total Downward 0.010 in
Left Support 1.03 1.28 Ratio 9999 >360 Ratio 7392 >240
Right Support 1.03 1.28
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : FBM208
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.150, L = 0.20 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.068 : 1
fb : Actual : 407.74 psi at 4.700 ft in Span # 1
Fb : Allowable : 6,001.70 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.061 : 1
fv : Actual : 38.12 psi at 8.241 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.013 in Total Downward 0.025 in
Left Support 0.81 0.94 Ratio 8434 >360 Ratio 4522 >240
Right Support 0.81 0.94
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

55 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : FBM209


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.330, L = 0.440 k/ft, 0.0 ft to 3.20 ft, Trib= 1.0 ft
Unif Load: D = 0.5131, Lr = 0.02660, L = 0.440 k/ft, 3.20 to 8.30 ft, Trib= 1.0 ft
Unif Load: D = 0.6684, Lr = 0.2750, L = 0.440 k/ft, 8.30 to 12.50 ft, Trib= 1.0 ft
Point: E = -5.316 k @ 3.20 ft
Point: D = 1.510, Lr = 2.420 k @ 8.30 ft
Point: D = 4.150, Lr = 3.720, L = 0.570, E = 5.316 k @ 11.0 ft
Design Summary .
Max fb/Fb Ratio = 0.540 : 1
fb : Actual : 3,202.20 psi at 8.292 ft in Span # 1
Fb : Allowable : 5,934.71 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.689 : 1
fv : Actual : 431.30 psi at 11.375 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.110 in Total Downward 0.344 in
Left Support 3.95 2.82 1.53 -3.32 Ratio 1366 >360 Ratio 436 >240
Right Support 8.47 3.25 5.90 3.32
LC: Lr Only LC: +D+0.750Lr+0.750L+H
Transient Upward -0.056 in Total Upward 0.000 in
Ratio 2682 Ratio 9999
LC: E Only LC:

56 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM210 Floor Beam Use: 5 1/4" x 14" PSL2.2

D1
Z

X D1
Y 12.3
7.7
Units = ft
     Floor  
DL1 = 30psf *12.3ft = 369.9 Lbs/ft
LL1 = 40psf *12.3ft =493.2 Lbs/ft
1
FBM211 Floor Beam Use: W 10x33

P1 1.3
D1
D2 D3
Z
9.0
X
D1 D2 D3
Y 11.0
4.3 6.3 15.1 4.8 11.0 7.8 11.0 4.8
Units = ft
     Floor  Deck
BEAM SUPP. DL Lr  LL  E Units DL1 = 30psf *11ft+26.5psf *4.8ft = 458 Lbs/ft
P1 LL1 = 40psf *11ft+40psf *4.8ft =633.2 Lbs/ft
HDR105 1 1830 2470 0 0 [Lbs]
Roof    Wall Ext.  Floor  Deck
DL2 = 12.5psf *1.3ft+18.5psf *9ft+30psf *11ft+26.5psf *7.8ft = 720.6 Lbs/ft
Lr2 = 20psf *1,3ft = 26.6 Lbs/ft
LL2 = 40psf *11ft+40psf *7.8ft = 753.2 Lbs/ft
     Floor  Deck
DL3 = 30psf *11ft+26.5psf *4.8ft = 458 Lbs/ft
LL3 = 40psf *11ft+40psf *4.8ft =633.2 Lbs/ft
1
FBM212 Floor Beam Use: W 10x33

P1 P2 P3
D1 1.3
D2 D3
Z 9.0

X D1 D2 D3
Y 10.8 4.8 10.84.8 10.84.8
2.1 8.1 13.0 17.5
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  Lower Roof
BEAM SUPP. DL Lr  LL E  Units DL1 = 30psf *10.8ft+10.5psf *4.8ft = 375.6 Lbs/ft
P1 Lr1 = 20psf *4.8ft = 96.6 Lbs/ft
HDR105 2 1510 1960 0 0 [Lbs] LL1 = 40psf *10,8ft = 433.2 Lbs/ft
E‐Line 6(R)  ‐ 0 0 0 ‐2375 [Lbs] Roof    Wall Ext.  Floor  Lower Roof
P2 DL2 = 12.5psf *1.3ft+18.5psf *9ft+30psf *10.8ft+10.5psf *4.8ft = 558.7 Lbs/ft
GT3 ‐ 1610 2570 0 0 [Lbs] Lr2 = 20psf *1,3ft+20psf *4.8ft = 123.2 Lbs/ft
P3 LL2 = 40psf *10,8ft = 433.2 Lbs/ft
E‐Line 6(R)  ‐ 0 0 0 2375 [Lbs]      Floor  Lower Roof
DL3 = 30psf *10.8ft+10.5psf *4.8ft = 375.6 Lbs/ft
Lr3 = 20psf *4.8ft = 96.6 Lbs/ft
LL3 = 40psf *10,8ft = 433.2 Lbs/ft
1

57 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM210
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3699, L = 0.4932 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.108 : 1
fb : Actual : 653.71 psi at 3.850 ft in Span # 1
Fb : Allowable : 6,034.57 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.111 : 1
fv : Actual : 69.33 psi at 6.545 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.015 in Total Downward 0.027 in
Left Support 1.51 1.90 Ratio 6222 >360 Ratio 3463 >240
Right Support 1.51 1.90
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Steel Beam Design : FBM211
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x33, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.4580, L = 0.6330 k/ft, 0.0 ft to 4.30 ft, Trib= 1.0 ft
Unif Load: D = 0.7206, Lr = 0.02660, L = 0.7532 k/ft, 4.30 to 6.30 ft, Trib= 1.0 ft
Unif Load: D = 0.4580, L = 0.6332 k/ft, 6.30 to 15.10 ft, Trib= 1.0 ft
Point: D = 1.830, Lr = 2.470 k @ 6.30 ft
Design Summary .
Max fb/Fb Ratio = 0.444 : 1
Mu : Applied 60.240 k-ft at 6.443 ft in Span # 1
Mn * Phi : Allow 135.678 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.174 : 1
Vu : Applied 14.771 k at 0.000 ft in Span # 1
Vn * Phi : Allow 84.651 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 5.11 4.94 1.47 Transient Downward 0.155 in Total Downward 0.334 in
Right Support 4.65 4.86 1.05 Ratio 1165 541
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

58 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Steel Beam Design : FBM212


Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x33, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3756, Lr = 0.09660, L = 0.4332 k/ft, 0.0 ft to 2.10 ft, Trib= 1.0 ft
Unif Load: D = 0.5587, Lr = 0.1232, L = 0.4332 k/ft, 2.10 to 13.0 ft, Trib= 1.0 ft
Unif Load: D = 0.3756, Lr = 0.09660, L = 0.4332 k/ft, 13.0 to 17.50 ft, Trib= 1.0 ft
Point: D = 1.510, Lr = 1.960, E = -2.375 k @ 2.10 ft
Point: D = 1.610, Lr = 2.570 k @ 8.10 ft
Point: E = 2.375 k @ 13.0 ft
Design Summary .
Max fb/Fb Ratio = 0.570 : 1
Mu : Applied 71.533 k-ft at 8.108 ft in Span # 1
Mn * Phi : Allow 125.515 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.198 : 1
Vu : Applied 16.764 k at 0.000 ft in Span # 1
Vn * Phi : Allow 84.651 k
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 6.90 3.79 4.12 -1.48 Transient Downward 0.185 in Total Downward 0.594 in
Right Support 5.36 3.79 2.40 1.48 Ratio 1133 353
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

59 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM213 Flush Beam Use: W 10x33

D1
Z

X D1
Y 1.3
14.8
Units = ft
     Floor  
DL1 = 30psf *1.3ft = 39.9 Lbs/ft
LL1 = 40psf *1.3ft =53.2 Lbs/ft
1
FBM214 Flush Beam Use: W 10x33

P1
D1
D2
Z

X
D1 D2
Y 1.3
5.6 15.3 1.3
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  
BEAM SUPP. DL Lr  LL  E Units DL1 = 30psf *1.3ft = 39.9 Lbs/ft
P1 LL1 = 40psf *1.3ft =53.2 Lbs/ft
FBM211 2 4650 1050 4860 0 [Lbs]
FBM212 1 6900 4120 3790 ‐1480 [Lbs]        Deck
DL2 = 26.5psf *1.3ft = 35.2 Lbs/ft
LL2 = 40psf *1.3ft =53.2 Lbs/ft
1
FBM215 Flush Beam Use: 7" x 14" PSL2.2

P1 P2
D1
D2
Z

X D1 D2
Y 4.8 4.8
13.3 16.4 18.7
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5        Deck
BEAM SUPP. DL Lr  LL E  Units DL1 = 26.5psf *4.8ft = 128 Lbs/ft
P1 LL1 = 40psf *4.8ft =193.2 Lbs/ft
FBM214 2 4790 1890 3570 540 [Lbs]
P2        Lower Roof
DBM101 2 320 480 0 0 [Lbs] DL2 = 10.5psf *4.8ft = 50.7 Lbs/ft
DBM102 2 70 60 0 0 [Lbs] Lr2 = 20psf *4.8ft = 96.6 Lbs/ft
1

60 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Steel Beam Design : FBM213
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x33, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0390, L = 0.05320 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.035 : 1
Mu : Applied 4.696 k-ft at 7.400 ft in Span # 1
Mn * Phi : Allow 132.956 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.015 : 1
Vu : Applied 1.269 k at 0.000 ft in Span # 1
Vn * Phi : Allow 84.651 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 0.53 0.39 Transient Downward 0.012 in Total Downward 0.027 in
Right Support 0.53 0.39 Ratio 9999 6481
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Steel Beam Design : FBM214
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x33, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0390, L = 0.05320 k/ft, Trib= 1.0 ft
Point: D = 11.550, Lr = 5.170, L = 8.650, E = 1.480 k @ 5.60 ft
Design Summary .
Max fb/Fb Ratio = 0.770 : 1
Mu : Applied 112.073 k-ft at 5.610 ft in Span # 1
Mn * Phi : Allow 145.500 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.242 : 1
Vu : Applied 20.512 k at 0.000 ft in Span # 1
Vn * Phi : Allow 84.651 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 7.87 5.89 3.28 0.94 Transient Downward 0.219 in Total Downward 0.548 in
Right Support 4.78 3.57 1.89 0.54 Ratio 839 334
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

61 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : FBM215


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 7x14, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1280, L = 0.1932 k/ft, 0.0 ft to 13.30 ft, Trib= 1.0 ft
Unif Load: D = 0.05070, L = 0.09660 k/ft, 13.30 to 18.80 ft, Trib= 1.0 ft
Point: D = 4.790, Lr = 1.890, L = 3.570, E = 0.540 k @ 13.30 ft
Point: D = 0.390, Lr = 0.540 k @ 16.40 ft
Design Summary .
Max fb/Fb Ratio = 0.570 : 1
fb : Actual : 3,417.40 psi at 13.285 ft in Span # 1
Fb : Allowable : 5,994.07 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.310 : 1
fv : Actual : 193.92 psi at 17.672 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.331 in Total Downward 0.716 in
Left Support 2.88 2.78 0.62 0.16 Ratio 682 >360 Ratio 315 >240
Right Support 4.86 3.89 1.81 0.38
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

62 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM216 Flush Beam Use: W 10x26

P2 7.5 7.5
P1
D1
D2
D3
Z 9.0 9.0

X D1 D2 D3
Y 1.3 2.9 1.3 2.9 1.3 2.9
3.4 7.6 15.9
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5 Roof    Wall Ext.  Floor  Lower Roof
BEAM SUPP DL Lr LL E Units DL1 = 12,5psf *7,5ft+18,5psf *9ft+30psf *1,3ft+10,5psf *2,9ft = 330,6 Lbs/ft
P1 Lr1 = 20psf *7,5ft+20psf *2,9ft = 208 Lbs/ft
HDR106 1 310 340 0 0 [Lbs] LL1 = 40psf *1,3ft = 53,2 Lbs/ft
P2      Floor  Lower Roof
HDR106 2 310 340 0 0 [Lbs] DL2 = 30psf *1,3ft+10,5psf *2,9ft = 70,4 Lbs/ft
E‐Line A(R)  ‐ 0 0 0 3229 [Lbs] Lr2 = 20psf *2,9ft = 58 Lbs/ft
LL2 = 40psf *1,3ft = 53,2 Lbs/ft
Roof    Wall Ext.  Floor  Lower Roof
DL3 = 12,5psf *7,5ft+18,5psf *9ft+30psf *1,3ft+10,5psf *2,9ft = 330,6 Lbs/ft
Lr3 = 20psf *7,5ft+20psf *2,9ft = 208 Lbs/ft
LL3 = 40psf *1,3ft = 53,2 Lbs/ft
1
FBM217 Flush Beam Use: W 10x26
7.5
P1 P2
D1
D2 D3
Z
9.0
X
D1 D2 D3
Y 1.3
1.5 6.0 15.7 2.8 1.3 2.8 5.0
Units = ft
Roof    Wall Ext.  Floor  Lower Roof
BEAM SUPP. DL Lr  LL  E Units DL1 = 12,5psf *7,5ft+18,5psf *9ft+30psf *1,3ft+10,5psf *2,8ft = 329,9 Lbs/ft
P1 Lr1 = 20psf *7,5ft+20psf *2,8ft = 206.6 Lbs/ft
HDR106 1 310 340 0 0 [Lbs] LL1 = 40psf *1,3ft = 53.2 Lbs/ft
E‐Line A(R)  ‐ 0 0 0 3229 [Lbs]      Floor  Lower Roof
P2 DL2 = 30psf *1,3ft+10,5psf *2,8ft = 69,6 Lbs/ft
FBM212 2 5360 2400 3790 1480 [Lbs] Lr2 = 20psf *2,8ft = 56.6 Lbs/ft
LL2 = 40psf *1,3ft = 53.2 Lbs/ft
       Lower Roof
DL3 = 10,5psf *5ft = 52,5 Lbs/ft
Lr3 = 20psf *5ft = 100 Lbs/ft
1
FBM218 Flush Beam Use: 5 1/4" x 14" PSL2.2

P1 P1 P1
D1
Z

X D1
Y 3.8
0.5 2.3 4.1 12.1
Units = ft
     Floor  
BEAM SUPP. DL Lr  LL E  Units DL1 = 30psf *3,8ft = 112,5 Lbs/ft
P1 LL1 = 40psf *3.8ft =150 Lbs/ft
Stringer 1 150 0 200 0 [Lbs]
P1
Stringer 1 150 0 200 0 [Lbs]
P1
Stringer 1 150 0 200 0 [Lbs]
1

63 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Steel Beam Design : FBM216
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x26, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3306, Lr = 0.2080, L = 0.05320 k/ft, 0.0 ft to 3.40 ft, Trib= 1.0 ft
Unif Load: D = 0.07040, Lr = 0.0850, L = 0.05320 k/ft, 3.40 to 7.60 ft, Trib= 1.0 ft
Unif Load: D = 0.3306, Lr = 0.2080, L = 0.05320 k/ft, 7.60 to 15.90 ft, Trib= 1.0 ft
Point: D = 0.310, Lr = 0.340 k @ 3.40 ft
Point: D = 0.310, Lr = 0.340, E = 3.229 k @ 7.60 ft
Design Summary .
Max fb/Fb Ratio = 0.561 : 1
Mu : Applied 47.489 k-ft at 7.579 ft in Span # 1
Mn * Phi : Allow 84.580 k-ft
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.102 : 1
Vu : Applied 8.188 k at 0.000 ft in Span # 1
Vn * Phi : Allow 80.340 k
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 2.53 0.42 1.76 1.69 Transient Downward 0.112 in Total Downward 0.187 in
Right Support 2.67 0.42 1.71 1.54 Ratio 1700 1020
LC: E Only LC: +D+0.70E+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Steel Beam Design : FBM217
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x26, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3299, Lr = 0.2066, L = 0.05232 k/ft, 0.0 ft to 1.50 ft, Trib= 1.0 ft
Unif Load: D = 0.06960, Lr = 0.05660, L = 0.05320 k/ft, 1.50 to 6.0 ft, Trib= 1.0 ft
Unif Load: D = 0.05250, Lr = 0.10 k/ft, 6.0 to 15.70 ft, Trib= 1.0 ft
Point: D = 0.310, Lr = 0.340, E = 3.229 k @ 1.50 ft
Point: D = 5.360, Lr = 2.40, L = 3.790, E = 1.480 k @ 6.0 ft
Design Summary .
Max fb/Fb Ratio = 0.680 : 1
Mu : Applied 62.391 k-ft at 6.018 ft in Span # 1
Mn * Phi : Allow 91.803 k-ft
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.222 : 1
Vu : Applied 17.832 k at 0.000 ft in Span # 1
Vn * Phi : Allow 80.340 k
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 4.66 2.60 2.58 3.83 Transient Downward 0.124 in Total Downward 0.373 in
Right Support 2.73 1.51 1.70 0.87 Ratio 1523 505
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : FBM218
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F - V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800 ksi Density 31.2 pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950 ksi
Applied Loads
Beam self weight calculated and added to loads 64 of 209
Unif Load: D = 0.1125, L = 0.150 k/ft, Trib= 1.0 ft
Point: D = 0.150, L = 0.20 k @ 0.50 ft
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Point: D = 0.150, L = 0.20 k @ 4.10 ft
Design Summary .
Max fb/Fb Ratio = 0.191 : 1
fb : Actual : 440.25 psi at 5.280 ft in Span # 1
Fb : Allowable : 2,305.60 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.142 : 1
fv : Actual : 37.68 psi at 0.000 ft in Span # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.041 in Total Downward 0.076 in
Left Support 1.13 1.39 Ratio 3470 >360 Ratio 1893 >240
Right Support 0.86 1.02
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

65 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

CBM201 Ceiling Beam Use: 4x6 D.F.#2

P1
D1
Z

X D1
Y 1.3
4.7 9.4
Units = ft
       Ceiling
BEAM SUPP DL Lr LL E Units DL1 = 6psf *1.3ft = 8 Lbs/ft
P1 Lr1 = 10psf *1.3ft = 13.3 Lbs/ft
HBM202 1 150 250 0 0 [Lbs]
HBM202 1 150 250 0 0 [Lbs]
1

66 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : CBM201
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 4x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875 psi Fc - Prll 600 psi Fv 170 psi Ebend- xx 1300 ksi Density 31.2 pcf
Fb - Compr 875 psi Fc - Perp 625 psi Ft 425 psi Eminbend - xx 470 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0080, Lr = 0.01330 k/ft, Trib= 1.0 ft
Point: D = 0.30, Lr = 0.50 k @ 4.70 ft
Design Summary .
Max fb/Fb Ratio = 0.880 : 1
fb : Actual : 2,123.35 psi at 4.700 ft in Span # 1
Fb : Allowable : 2,413.31 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.156 : 1
fv : Actual : 57.11 psi at 8.961 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.275 in Total Downward 0.452 in
Left Support 0.21 0.31 Ratio 409 >360 Ratio 249 >240
Right Support 0.21 0.31
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

67 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

DBM201 Drop Beam Use: 3 1/2" x 11 1/4" PSL2.2

D1
Z

X D1
Y 4.3
19.8
Units = ft
       Lower Roof
DL1 = 10.5psf *4.3ft = 45.5 Lbs/ft
Lr1 = 20psf *4.3ft = 86.6 Lbs/ft
1
DBM202 Drop Beam Use: 4x10 D.F.#2

P1 P2
D1
D2
Z

X
D1 D2
Y
3.7 8.4 9.3 4.3 4.7
Units = ft
       Lower Roof
BEAM SUPP. DL Lr  LL  E Units DL1 = 10.5psf *4.3ft = 44.6 Lbs/ft
P1 Lr1 = 20psf *4.3ft = 85 Lbs/ft
CBM201 1 210 310 0 0 [Lbs]
P2        Ceiling
HBM202 2 160 210 0 0 [Lbs] DL2 = 6psf *4.7ft = 28 Lbs/ft
Lr2 = 10psf *4.7ft = 46.7 Lbs/ft
1
DBM203 Drop Beam Use: 5 1/4" x 9 1/2 PSL2.2

P1
D1
D2
Z

X D1 D2
Y 1.3 1.3
1.3 6.5
Units = ft
     Floor  
BEAM SUPP. DL Lr  LL E  Units DL1 = 30psf *1.3ft = 39.9 Lbs/ft
P1 LL1 = 40psf *1.3ft =53.2 Lbs/ft
FBM211 1 5110 1470 4940 0 [Lbs]
       Deck
DL2 = 26.5psf *1.3ft = 35.2 Lbs/ft
LL2 = 40psf *1.3ft =53.2 Lbs/ft
1

68 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : DBM201
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 3.5x11.25, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.04550, Lr = 0.08660 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.371 : 1
fb : Actual : 1,656.31 psi at 9.900 ft in Span # 1
Fb : Allowable : 4,461.15 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.114 : 1
fv : Actual : 71.10 psi at 18.876 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.330 in Total Downward 0.550 in
Left Support 0.57 0.86 Ratio 721 >360 Ratio 432 >240
Right Support 0.57 0.86
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : DBM202
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 4x10, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.07260, Lr = 0.1317 k/ft, Trib= 1.0 ft
Point: D = 0.210, Lr = 0.310 k @ 3.70 ft
Point: D = 0.160, Lr = 0.210 k @ 8.40 ft
Design Summary .
Max fb/Fb Ratio = 0.552 : 1
fb : Actual : 1,209.73 psi at 3.844 ft in Span # 1
Fb : Allowable : 2,191.80 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.249 : 1
fv : Actual : 91.31 psi at 8.556 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.108 in Total Downward 0.177 in
Left Support 0.51 0.82 Ratio 1029 >360 Ratio 630 >240
Right Support 0.60 0.93
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

69 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : DBM203


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x9.5, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.03990, L = 0.05320 k/ft, 0.0 ft to 1.30 ft, Trib= 1.0 ft
Unif Load: D = 0.03520, L = 0.05320 k/ft, 1.30 to 6.50 ft, Trib= 1.0 ft
Point: D = 5.110, Lr = 1.470, L = 4.940 k @ 1.30 ft
Design Summary .
Max fb/Fb Ratio = 0.389 : 1
fb : Actual : 2,409.98 psi at 1.300 ft in Span # 1
Fb : Allowable : 6,202.58 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.585 : 1
fv : Actual : 366.31 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.037 in Total Downward 0.075 in
Left Support 4.26 4.12 1.18 Ratio 2104 >360 Ratio 1036 >240
Right Support 1.19 1.16 0.29
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

70 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

DBM204 Drop Beam Use: 5 1/4" x 9 1/2" PSL2.2

P1
D1 D2
Z

X D1 D2
Y 5.3 1.3
5.0 12.7
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5        Lower Roof
BEAM SUPP DL Lr LL E Units DL1 = 10.5psf *5.3ft = 56 Lbs/ft
P1 Lr1 = 20psf *5.3ft = 106.6 Lbs/ft
FBM217 2 2730 1700 1510 870 [Lbs]
       Lower Roof
DL2 = 10.5psf *1.3ft = 14 Lbs/ft
Lr2 = 20psf *1.3ft = 26.6 Lbs/ft
1
DBM205 Drop Beam Use: 5 1/4" x 14" PSL2.2
1.3
P1 P2 P3
D1
D2 D3
Z D4 9.0
X
D1 D2 D3 D4
Y
3.7 8.2 14.2 16.6 1.3 2.5 1.3 2.5 1.3 2.5 1.3
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5        Lower Roof
BEAM SUPP. DL Lr  LL  E Units DL1 = 10.5psf *1.3ft = 14 Lbs/ft
P1 Lr1 = 20psf *1.3ft = 26.6 Lbs/ft
HDR101 1 330 380 0 0 [Lbs]
HBM201 2 190 310 0 0 [Lbs]      Floor  Lower Roof
FBM201 1 3890 1620 2520 1680 [Lbs] DL2 = 30psf *1.3ft+10.5psf *2.5ft = 66.2 Lbs/ft
P2 Lr2 = 20psf *2.5ft = 50 Lbs/ft
E‐Line 1(R)  ‐ 0 0 0 1790 [Lbs] LL2 = 40psf *1,3ft = 53.2 Lbs/ft
P3 Roof    Wall Ext.  Floor  Lower Roof
HDR102 1 770 1130 0 0 [Lbs] DL3 = 12.5psf *1.3ft+18.5psf *9ft+30psf *1.3ft+10.5psf *2.5ft = 249.3 Lbs/ft
E‐Line 1(R)  ‐ 0 0 0 ‐1790 [Lbs] Lr3 = 20psf *1,3ft+20psf *2.5ft = 76.6 Lbs/ft
LL3 = 40psf *1,3ft = 53.2 Lbs/ft
     Floor  Lower Roof
DL4 = 30psf *1.3ft+10.5psf *2.5ft = 66.2 Lbs/ft
Lr4 = 20psf *2.5ft = 50 Lbs/ft
1 LL4 = 40psf *1,3ft = 53.2 Lbs/ft

71 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : DBM204
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x9.5, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0560, Lr = 0.1066 k/ft, 0.0 ft to 5.0 ft, Trib= 1.0 ft
Unif Load: D = 0.0140, Lr = 0.02660 k/ft, 5.0 to 12.70 ft, Trib= 1.0 ft
Point: D = 2.730, Lr = 1.70, L = 1.510, E = 0.870 k @ 5.0 ft
Design Summary .
Max fb/Fb Ratio = 0.577 : 1
fb : Actual : 3,540.95 psi at 4.995 ft in Span # 1
Fb : Allowable : 6,135.85 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.245 : 1
fv : Actual : 153.68 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.182 in Total Downward 0.494 in
Left Support 2.01 0.92 1.52 0.53 Ratio 837 >360 Ratio 308 >240
Right Support 1.30 0.59 0.92 0.34
LC: Lr Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : DBM205
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0140, Lr = 0.02660 k/ft, 0.0 ft to 3.70 ft, Trib= 1.0 ft
Unif Load: D = 0.06620, Lr = 0.050, L = 0.05320 k/ft, 3.70 to 8.20 ft, Trib= 1.0 ft
Unif Load: D = 0.2493, Lr = 0.07660, L = 0.05320 k/ft, 8.20 to 14.20 ft, Trib= 1.0 ft
Unif Load: D = 0.06620, Lr = 0.050, L = 0.05320 k/ft, 14.20 to 16.60 ft, Trib= 1.0 ft
Point: D = 4.410, Lr = 2.310, L = 2.520 k @ 3.70 ft
Point: E = 1.790 k @ 8.20 ft
Point: D = 0.450, Lr = 0.630, E = -1.790 k @ 14.20 ft
Design Summary .
Max fb/Fb Ratio = 0.459 : 1
fb : Actual : 2,673.31 psi at 8.189 ft in Span # 1
Fb : Allowable : 5,818.37 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.324 : 1
fv : Actual : 203.17 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.146 in Total Downward 0.502 in
Left Support 4.42 2.22 2.28 0.65 Ratio 1360 >360 Ratio 396 >240
Right Support 2.83 0.98 1.57 -0.65
LC: Lr Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

72 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

HDR201 Header Beam Use: 6x6 D.F.#2

D1 4.7
D2
Z

X D1 D2
Y 2.0
4.3
Units = ft
       Lower Roof
DL1 = 10.5psf *4.7ft = 49 Lbs/ft
Lr1 = 20psf *4.7ft = 93.4 Lbs/ft
       Brick Veneer Ext. Wall
DL2 = 22psf *2ft = 44 Lbs/ft
1
HDR202 Header Beam Use: 5 1/4 x 5 1/4 PSL2.2

D1
D3 D2
Z

X
D1 D2 D3
Y
3.4 4.5 1.3 1.3 2.0
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5        Lower Roof
BEAM SUPP. DL Lr  LL  E Units DL1 = 10.5psf *1.3ft = 14 Lbs/ft
FBM201 3 ‐1570 ‐900 ‐400 190 [Lbs] Lr1 = 20psf *1.3ft = 26.6 Lbs/ft
     Floor  
DL2 = 30psf *1.3ft = 39.9 Lbs/ft
LL2 = 40psf *1.3ft =53.2 Lbs/ft
       Brick Veneer Ext. Wall
DL3 = 22psf *2ft = 44 Lbs/ft
1
HDR203 Header Beam Use: 6x6 D.F.#2
7.6 1.3

D1
Z 9.0

X D1
Y
6.4
Units = ft
Roof    Wall Ext.  Floor  
DL1 = 12.5psf *7.6ft+18.5psf *9ft+30psf *1.3ft = 301.2 Lbs/ft
Lr1 = 20psf *7.6ft = 151.6 Lbs/ft
LL1 = 40psf *1.3ft = 53.2 Lbs/ft
1

73 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : HDR201
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0930, Lr = 0.09340 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.139 : 1
fb : Actual : 262.74 psi at 2.125 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.061 : 1
fv : Actual : 22.29 psi at 3.797 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.007 in Total Downward 0.014 in
Left Support 0.21 0.20 Ratio 7334 >360 Ratio 3550 >240
Right Support 0.21 0.20
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : HDR202
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x5.25, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0580, Lr = 0.02660 k/ft, 0.0 ft to 3.420 ft, Trib= 1.0 ft
Unif Load: D = 0.03990, Lr = 0.05320 k/ft, 3.420 to 4.50 ft, Trib= 1.0 ft
Point: D = -1.540, Lr = -0.90, L = -0.40, E = 0.190 k @ 3.420 ft
Design Summary .
Max fb/Fb Ratio = 0.209 : 1
fb : Actual : 1,307.35 psi at 3.420 ft in Span # 1
Fb : Allowable : 6,264.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.218 : 1
fv : Actual : 136.50 psi at 3.435 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.003 in Total Downward 0.000 in
Left Support -0.22 -0.10 -0.15 0.05 Ratio 9999 >360 Ratio 9999 >240
Right Support -1.04 -0.30 -0.60 0.14
LC: E Only LC:
Transient Upward -0.012 in Total Upward -0.035 in
Ratio 4348 Ratio 1562
LC: Lr Only LC: +D+0.750Lr+0.750L+H

74 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : HDR203


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875 psi Fc - Prll 600 psi Fv 170 psi Ebend- xx 1300 ksi Density 31.2 pcf
Fb - Compr 875 psi Fc - Perp 625 psi Ft 425 psi Eminbend - xx 470 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3012, Lr = 0.1516, L = 0.05320 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.748 : 1
fb : Actual : 1,414.66 psi at 3.200 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.237 : 1
fv : Actual : 87.13 psi at 5.952 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.058 in Total Downward 0.177 in
Left Support 0.98 0.17 0.49 Ratio 1323 >360 Ratio 434 >240
Right Support 0.98 0.17 0.49
LC: Lr Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

75 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

HDR204 Header Beam Use: 5 1/4" x 9 1/2" PSL2.2


1.3
P1
D1 1.3 9.0 1.3
D2
Z 2.0 2.0

X D1 D2
Y
1.1 3.4
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5    Wall Int.    Lower Roof
BEAM SUPP DL Lr LL E Units DL1 = 8,5psf *2ft+10,5psf *1,3ft = 31 Lbs/ft
P1 Lr1 = 20psf *1,3ft = 26,6 Lbs/ft
FBM201 2 11840 5310 6460 1490 [Lbs]
Roof    Wall Int.  Floor  
DL2 = 12,5psf *1,3ft+8,5psf *11ft+30psf *1,3ft = 150 Lbs/ft
Lr2 = 20psf *1,3ft = 26,6 Lbs/ft
LL2 = 40psf *1,3ft = 53,2 Lbs/ft
1
HDR205 Header Beam Use: 6x6 D.F.#2

D1
D2
Z

X
D1 D2
Y
6.3 4.3 2.0
Units = ft
       Lower Roof
DL1 = 10,5psf *4,3ft = 44,6 Lbs/ft
Lr1 = 20psf *4,3ft = 85 Lbs/ft
       Brick Veneer Ext. Wall
DL2 = 22psf *2ft = 44 Lbs/ft
1
HDR206 Header Beam Use: 6x6 D.F.#2
8.6

D1 9.0 8.8
Z 2.0

X D1
Y
4.5
Units = ft
Roof    Wall Ext.  Floor  
DL1 = 12,5psf *8,6ft+18,5psf *11ft+30psf *8,8ft = 575,7 Lbs/ft
Lr1 = 20psf *8,6ft = 171,6 Lbs/ft
LL1 = 40psf *8,8ft = 353,2 Lbs/ft
1

76 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : HDR204
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x9.5, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0310, Lr = 0.02660 k/ft, 0.0 ft to 1.10 ft, Trib= 1.0 ft
Unif Load: D = 0.150, Lr = 0.02660, L = 0.05320 k/ft, 1.10 to 3.40 ft, Trib= 1.0 ft
Point: D = 11.840, Lr = 5.310, L = 6.460, E = 1.490 k @ 1.10 ft
Design Summary .
Max fb/Fb Ratio = 0.500 : 1
fb : Actual : 3,116.59 psi at 1.099 ft in Span # 1
Fb : Allowable : 6,233.28 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.895 : 1
fv : Actual : 560.61 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.010 in Total Downward 0.031 in
Left Support 8.18 4.41 3.64 1.01 Ratio 4272 >360 Ratio 1326 >240
Right Support 4.09 2.17 1.76 0.48
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : HDR205
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.08860, Lr = 0.0850 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.284 : 1
fb : Actual : 537.15 psi at 3.150 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.092 : 1
fv : Actual : 33.61 psi at 5.859 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.031 in Total Downward 0.065 in
Left Support 0.30 0.27 Ratio 2474 >360 Ratio 1167 >240
Right Support 0.30 0.27
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

77 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : HDR206


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.5757, Lr = 0.1716, L = 0.3532 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.782 : 1
fb : Actual : 1,478.40 psi at 2.250 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.328 : 1
fv : Actual : 120.46 psi at 0.000 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.033 in Total Downward 0.091 in
Left Support 1.31 0.79 0.39 Ratio 1633 >360 Ratio 591 >240
Right Support 1.31 0.79 0.39
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

78 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

HDR207 Header Beam Use: 6x6 D.F.#2

D1
Z

X D1
Y 1.3
5.7
Units = ft
       Lower Roof
DL1 = 10,5psf *1,3ft = 14 Lbs/ft
Lr1 = 20psf *1,3ft = 26,6 Lbs/ft
1
HDR208 Header Beam Use: 6x6 D.F.#2

D1
Z

X
D1
Y
6.4 3.2
Units = ft
       Lower Roof
DL1 = 10,5psf *3,2ft = 33,3 Lbs/ft
Lr1 = 20psf *3,2ft = 63,4 Lbs/ft
1
HDR209 Header Beam Use: 6x8 D.F.#2

D1
Z 1.5

X D1
Y
19.8
Units = ft
   Wall Ext.    
DL1 = 18,5psf *1,5ft = 27,8 Lbs/ft
1

79 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : HDR207
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0140, Lr = 0.02660 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.063 : 1
fb : Actual : 118.15 psi at 2.850 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.022 : 1
fv : Actual : 7.98 psi at 5.244 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.006 in Total Downward 0.011 in
Left Support 0.06 0.08 Ratio 9999 >360 Ratio 6022 >240
Right Support 0.06 0.08
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : HDR208
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x6, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875.0 psi Fc - Prll 600.0 psi Fv 170.0 psi Ebend- xx 1,300.0 ksi Density 31.20 pcf
Fb - Compr 875.0 psi Fc - Perp 625.0 psi Ft 425.0 psi Eminbend - xx 470.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.03330, Lr = 0.06340 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.175 : 1
fb : Actual : 330.73 psi at 3.200 ft in Span # 1
Fb : Allowable : 1,890.00 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.055 : 1
fv : Actual : 20.37 psi at 5.952 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.024 in Total Downward 0.040 in
Left Support 0.13 0.20 Ratio 3164 >360 Ratio 1942 >240
Right Support 0.13 0.20
LC: Lr Only LC: +D+Lr+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

80 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : HDR209


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 6x8, Sawn, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir - Larch Wood Grade : No.2
Fb - Tension 875 psi Fc - Prll 600 psi Fv 170 psi Ebend- xx 1300 ksi Density 31.2 pcf
Fb - Compr 875 psi Fc - Perp 625 psi Ft 425 psi Eminbend - xx 470 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.02780 k/ft, Trib= 1.0 ft
Design Summary .
Max fb/Fb Ratio = 0.314 : 1
fb : Actual : 583.62 psi at 9.875 ft in Span # 1
Fb : Allowable : 1,860.96 psi
Load Comb : +1.40D+1.60H
Max fv/FvRatio = 0.047 : 1
fv : Actual : 17.36 psi at 0.000 ft in Span # 1
Fv : Allowable : 367.20 psi
Load Comb : +1.40D+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.000 in Total Downward 0.503 in
Left Support 0.36 Ratio 9999 >360 Ratio 471 >240
Right Support 0.36
LC: LC: +D+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

81 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM301 Flush Beam Use: 3 1/2" x 14" PSL2.2

P1 P2
D1
D2
D3
Z
9.0

X D1 D2 D3
Y 1.7 1.7 1.7
3.4 8.2 16.0
Units = ft
     Floor  
BEAM SUPP DL Lr LL E Units DL1 = 30psf *1,7ft = 50,1 Lbs/ft
P1 LL1 = 40psf *1,7ft =66,8 Lbs/ft
FBM 1 400 0 470 [Lbs]
P2    Wall Ext.  Floor  
FBM 1 400 470 [Lbs] DL2 = 18,5psf *9ft+30psf *1,7ft = 216,6 Lbs/ft
LL2 = 40psf *1,7ft =66,8 Lbs/ft
     Floor  
DL3 = 30psf *1,7ft = 50,1 Lbs/ft
LL3 = 40psf *1,7ft =66,8 Lbs/ft
1
FBM302 Flush Beam Use: 3 1/2" x 14" PSL2.2

P1 P2
D1
D2 D3
Z
9.0
X
D1 D2 D3
Y 1.7
3.4 8.2 16.0 1.7 1.7
Units = ft
     Floor  
BEAM SUPP. DL Lr  LL  E Units DL1 = 30psf *1,7ft = 50,1 Lbs/ft
P1 LL1 = 40psf *1,7ft =66,8 Lbs/ft
FBM 2 400 0 470 0 [Lbs]
P2    Wall Ext.  Floor  
FBM 2 400 0 470 0 [Lbs] DL2 = 18,5psf *9ft+30psf *1,7ft = 216,6 Lbs/ft
LL2 = 40psf *1,7ft =66,8 Lbs/ft
     Floor  
DL3 = 30psf *1,7ft = 50,1 Lbs/ft
LL3 = 40psf *1,7ft =66,8 Lbs/ft
1
FBM303 Flush Beam Use: 5 1/4" x 14" PSL2.2

P1 P2
D1
Z

X D1
Y 1.7
1.5 13.8 15.1
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  
BEAM SUPP. DL Lr  LL E 
Units DL1 = 30psf *1,7ft = 50,1 Lbs/ft
P1 LL1 = 40psf *1,7ft =66,8 Lbs/ft
FBM209 1 3950 1530 2820 ‐3320 [Lbs]
P2
FBM209 2 8470 5900 3250 3320 [Lbs]
1

82 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM301
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 3.5x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.05010, L = 0.06680 k/ft, 0.0 ft to 3.40 ft, Trib= 1.0 ft
Unif Load: D = 0.2166, L = 0.06680 k/ft, 3.40 to 8.20 ft, Trib= 1.0 ft
Unif Load: D = 0.05010, L = 0.06680 k/ft, 8.20 to 16.0 ft, Trib= 1.0 ft
Point: D = 0.40, L = 0.470 k @ 3.40 ft
Point: D = 0.40, L = 0.470 k @ 8.20 ft
Design Summary .
Max fb/Fb Ratio = 0.372 : 1
fb : Actual : 1,638.39 psi at 8.107 ft in Span # 1
Fb : Allowable : 4,406.92 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.169 : 1
fv : Actual : 105.85 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.120 in Total Downward 0.287 in
Left Support 1.54 1.13 Ratio 1605 >360 Ratio 669 >240
Right Support 1.10 0.88
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : FBM302
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 3.5x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.05010, L = 0.06680 k/ft, 0.0 ft to 3.40 ft, Trib= 1.0 ft
Unif Load: D = 0.2166, L = 0.06680 k/ft, 3.40 to 8.20 ft, Trib= 1.0 ft
Unif Load: D = 0.05010, L = 0.06680 k/ft, 8.20 to 16.0 ft, Trib= 1.0 ft
Point: D = 0.40, L = 0.470 k @ 3.40 ft
Point: D = 0.40, L = 0.470 k @ 8.20 ft
Design Summary .
Max fb/Fb Ratio = 0.372 : 1
fb : Actual : 1,638.39 psi at 8.107 ft in Span # 1
Fb : Allowable : 4,406.92 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.169 : 1
fv : Actual : 105.85 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.120 in Total Downward 0.287 in
Left Support 1.54 1.13 Ratio 1605 >360 Ratio 669 >240
Right Support 1.10 0.88
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

83 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Wood Beam Design : FBM303


Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.05010, L = 0.06680 k/ft, 0.0 ft to 15.10 ft, Trib= 1.0 ft
Point: D = 3.950, Lr = 1.530, L = 2.820, E = -3.320 k @ 1.50 ft
Point: D = 8.470, Lr = 5.90, L = 3.250, E = 3.320 k @ 13.80 ft
Design Summary .
Max fb/Fb Ratio = 0.327 : 1
fb : Actual : 1,918.36 psi at 13.791 ft in Span # 1
Fb : Allowable : 5,865.24 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H
Max fv/FvRatio = 0.685 : 1
fv : Actual : 429.18 psi at 13.942 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+1.60Lr+0.50L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.108 in Total Downward 0.341 in
Left Support 4.84 3.32 1.89 -2.70 Ratio 1675 >360 Ratio 532 >240
Right Support 8.69 3.75 5.54 2.70
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward -0.015 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: E Only LC:

84 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM304 Flush Beam Use: 5 1/4" x 14" PSL2.2


7.5
P1
D1 9.0 1.3
D2
Z 9.0 10.0

X D1 D2
Y 7.5 7.5
2.3 6.8
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5    Wall Ext.  Floor  
BEAM SUPP DL Lr LL E Units DL1 = 18,5psf *9ft+30psf *7,5ft = 391,5 Lbs/ft
P1 LL1 = 40psf *7.5ft =300 Lbs/ft
FBM303 1 4840 1890 3320 ‐2700 [Lbs]
Roof    Wall Ext.  Floor  Floor
DL2 = 12,5psf *7,5ft+18,5psf *19ft+30psf *7,5ft+30psf *1,3ft = 710,2 Lbs/ft
Lr2 = 20psf *7,5ft = 150 Lbs/ft
LL2 = 40psf *7.5ft+40psf *1.3ft = 353.2 Lbs/ft
1
FBM305 Flush Beam Use: 5 1/4" x 14" PSL2.2

7.5
P1
D1 9.0 1.3
D2
Z
10.0
X
D1 D2
Y 7.5
6.3 9.6 7.5
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  
BEAM SUPP. DL Lr  LL  E Units DL1 = 30psf *7,5ft = 225 Lbs/ft
P1 LL1 = 40psf *7.5ft =300 Lbs/ft
HDR203 2 980 490 170 0 [Lbs]
E‐Line C (2F)  ‐ 0 0 0 4101 [Lbs] Roof    Wall Ext.  Floor  Floor
DL2 = 12,5psf *7,5ft+18,5psf *19ft+30psf *7,5ft+30psf *1,3ft = 710,2 Lbs/ft
Lr2 = 20psf *7,5ft = 150 Lbs/ft
LL2 = 40psf *7.5ft+40psf *1.3ft = 353.2 Lbs/ft
1
FBM306 Flush Beam Use: W 10x39
1.3
P1 P2
D1 1.7 9.0 1.7
D2 D3
Z 10.0 10.0

X D1 D2 D3
Y 1.7
1.8 6.1 17.4 20.1
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  
BEAM SUPP. DL Lr  LL E 
Units DL1 = 30psf *1.7ft = 50.1 Lbs/ft
P1 LL1 = 40psf *1,7ft =66.8 Lbs/ft
HDR202 1 ‐220 ‐150 ‐100 50 [Lbs]
P2    Wall Ext.  Floor  
HDR202 2 ‐1040 ‐600 ‐300 140 [Lbs] DL2 = 18.5psf *10ft+30psf *1.7ft = 235.1 Lbs/ft
E‐Line 2(2F) ‐ 0 0 0 10685 [Lbs] LL2 = 40psf *1,7ft =66.8 Lbs/ft
Roof    Wall Ext.  Floor  
DL3 = 12.5psf *1.3ft+18.5psf *19ft+30psf *1.7ft = 418.2 Lbs/ft
Lr3 = 20psf *1,3ft = 26.6 Lbs/ft
LL3 = 40psf *1,7ft = 66.8 Lbs/ft
1

85 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM304
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.3915, L = 0.30 k/ft, 0.0 ft to 2.250 ft, Trib= 1.0 ft
Unif Load: D = 0.7102, Lr = 0.150, L = 0.3532 k/ft, 2.250 to 6.750 ft, Trib= 1.0 ft
Point: D = 4.840, Lr = 1.890, L = 3.320, E = 2.70 k @ 2.30 ft
Design Summary .
Max fb/Fb Ratio = 0.338 : 1
fb : Actual : 2,048.82 psi at 2.295 ft in Span # 1
Fb : Allowable : 6,054.16 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.416 : 1
fv : Actual : 260.38 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.018 in Total Downward 0.050 in
Left Support 5.07 3.28 1.47 1.78 Ratio 4448 >360 Ratio 1629 >240
Right Support 4.00 2.30 1.09 0.92
LC: L Only LC: +D+0.750Lr+0.750L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Wood Beam Design : FBM305
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.2250, L = 0.30 k/ft, 0.0 ft to 6.250 ft, Trib= 1.0 ft
Unif Load: D = 0.7102, Lr = 0.150, L = 0.3532 k/ft, 6.250 to 9.50 ft, Trib= 1.0 ft
Point: D = 0.980, Lr = 0.490, L = 0.170, E = 4.101 k @ 6.250 ft
Design Summary .
Max fb/Fb Ratio = 0.386 : 1
fb : Actual : 2,313.27 psi at 6.238 ft in Span # 1
Fb : Allowable : 5,999.76 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.352 : 1
fv : Actual : 220.43 psi at 8.360 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.042 in Total Downward 0.076 in
Left Support 1.78 1.51 0.25 1.40 Ratio 2709 >360 Ratio 1502 >240
Right Support 3.13 1.68 0.73 2.70
LC: E Only LC: +D+0.750L+0.750S+0.5250E
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

86 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED

Steel Beam Design : FBM306


Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
STEEL Section : W10x39, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.2852, L = 0.1336 k/ft, 0.0 ft to 1.750 ft, Trib= 1.0 ft
Unif Load: D = 0.2351, L = 0.06680 k/ft, 1.750 to 6.10 ft, Trib= 1.0 ft
Unif Load: D = 0.4683, Lr = 0.02660, L = 0.1336 k/ft, 6.10 to 20.10 ft, Trib= 1.0 ft
Point: D = -0.220, Lr = -0.150, L = -0.10 k @ 1.750 ft
Point: D = -1.040, Lr = -0.60, L = -0.30, E = 10.685 k @ 6.10 ft
Design Summary .
Max fb/Fb Ratio = 0.849 : 1
Mu : Applied 136.052 k-ft at 6.097 ft in Span # 1
Mn * Phi : Allow 160.312 k-ft
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max fv/FvRatio = 0.251 : 1
Vu : Applied 23.554 k at 0.000 ft in Span # 1
Vn * Phi : Allow 93.744 k
Load Comb : +1.490D+0.50L+0.20S+2.50E+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 3.05 0.81 -0.43 7.44 Transient Downward 0.419 in Total Downward 0.528 in
Right Support 4.55 1.19 0.05 3.24 Ratio 575 456
LC: E Only LC: +D+0.70E+H
Transient Upward -0.013 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: Lr Only LC:

87 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

FBM307 Flushh Beam Use: 5 1/4" x 14" PSL2.2

P1 P1 P1 P1 P1 P1
D1
Z

X D1
11.7
Y 3.8
0.5 2.3 4.1 8.1 9.9 12.2
Units = ft
     Floor  
BEAM SUPP DL Lr LL E Units DL1 = 30psf *3,8ft = 112,5 Lbs/ft
P1 LL1 = 40psf *3,8ft =150 Lbs/ft
Stringer 1 150 200 [Lbs]
P1
Stringer 1 150 200 [Lbs]
P1
Stringer 1 150 200 [Lbs]
P1
Stringer 1 150 200 [Lbs]
P1
Stringer 1 150 200 [Lbs]
P1
Stringer 1 150 200 [Lbs]
1
FBM308 Flush Beam Use: W 10x39

FBM207 FBM207 FBM208


FBM302 FBM208 P1 8.8
D2 D1 8.8
Z D3
D4 10.0 10.0 10.0
X
16.1 28.2 D1 D2 D3 D4
Y 18.0
5.8 7.8 9.6 18.1 18.9 29.2 34.0 8.8
Units = ft
Disc. System  Sds = 1,448 Ω = 2.5      Floor  
BEAM SUPP. DL Lr  LL  E Units DL1 = 30psf *18ft = 540 Lbs/ft
FBM302 1 1540 0 1130 0 [Lbs] LL1 = 40psf *18ft =720 Lbs/ft
FBM207 1 1030 0 1280 0 [Lbs]
FBM207 2 1030 0 1280 0 [Lbs]    Wall Ext.  Floor  
FBM208 1 810 0 940 0 [Lbs] DL2 = 18,5psf *10ft+30psf *8,8ft = 447,5 Lbs/ft
FBM208 2 810 0 940 0 [Lbs] LL2 = 40psf *8,8ft =350 Lbs/ft
P1
FBM210 1 1510 0 1900 0 [Lbs]    Wall Ext.  Floor  
FBM213 1 530 0 390 0 [Lbs] DL3 = 18,5psf *10ft+30psf *8,8ft = 447,5 Lbs/ft
FBM303 2 8690 5540 3750 2700 [Lbs] LL3 = 40psf *8,8ft =350 Lbs/ft
   Wall Ext.  Floor  
DL4 = 18,5psf *10ft+30psf *8,8ft = 447,5 Lbs/ft
LL4 = 40psf *8,8ft =350 Lbs/ft
1

88 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Multiple Simple Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description :
Wood Beam Design : FBM307
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
BEAM Size : 5.25x14.0, Parallam PSL, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.2E
Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,200.0 ksi Density 45.050 pcf
Fb - Compr 2,900.0 psi Fc - Perp 625.0 psi Ft 2,025.0 psi Eminbend - xx 1,118.19 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.1125, L = 0.150 k/ft, Trib= 1.0 ft
Point: D = 0.150, L = 0.20 k @ 0.50 ft
Point: D = 0.150, L = 0.20 k @ 2.30 ft
Point: D = 0.150, L = 0.20 k @ 4.10 ft
Point: D = 0.150, L = 0.20 k @ 8.10 ft
Point: D = 0.150, L = 0.20 k @ 9.90 ft
Point: D = 0.150, L = 0.20 k @ 11.70 ft
Design Summary .
Max fb/Fb Ratio = 0.129 : 1
fb : Actual : 765.50 psi at 6.100 ft in Span # 1
Fb : Allowable : 5,941.88 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.098 : 1
fv : Actual : 61.17 psi at 0.000 ft in Span # 1
Fv : Allowable : 626.40 psi
Load Comb : +1.20D+0.50Lr+1.60L+1.60H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.044 in Total Downward 0.081 in
Left Support 1.28 1.52 Ratio 3360 >360 Ratio 1816 >240
Right Support 1.28 1.52
LC: L Only LC: +D+L+H
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:

89 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Beam ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM308

CODE REFERENCES
Calculations per AISC 360-10, IBC 2015, ASCE 7-10
Load Combination Set :
Material Properties
Analysis Method : Load Resistance Factor Design Fy : Steel Yield : 50.0 ksi
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling E: Modulus : 29,000.0 ksi
Bending Axis : Major Axis Bending

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Beam self weight calculated and added to loading
Load for Span Number 1
Uniform Load : D = 0.540, L = 0.720 k/ft, Tributary Width = 1.0 ft

Point Load : D = 1.540, L = 1.130 k @ 5.80 ft

Load for Span Number 2


Uniform Load : D = 0.9875, L = 1.070 k/ft, Extent = 0.0 -->> 1.80 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.540, L = 0.720 k/ft, Extent = 1.80 -->> 8.30 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.9875, L = 1.070 k/ft, Extent = 8.30 -->> 10.30 ft, Tributary Width = 1.0 ft

Point Load : D = 1.030, L = 1.280 k @ 1.80 ft

Point Load : D = 1.030, L = 1.280 k @ 8.30 ft

Load(s) for Span Number 3


Point Load : D = 0.810, L = 0.940 k @ 0.80 ft

Point Load : D = 0.810, L = 0.940 k @ 10.10 ft

Point Load : D = 10.730, Lr = 5.540, L = 6.040, E = 2.70 k @ 11.10 ft

Uniform Load : D = 0.540, L = 0.720 k/ft, Extent = 0.0 -->> 10.10 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.9875, L = 1.070 k/ft, Extent = 10.10 -->> 11.10 ft, Tributary Width = 1.0 ft

Uniform Load : D = 0.540, L = 0.720 k/ft, Extent = 11.10 -->> 15.90 ft, Tributary Width = 1.0 ft

90 of 209
APPENDIX III

Knee Brace Calculations

91 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

SEISMIC LOADS: Trellis


Trellis DL: 5.0 lbs./sq.ft.

COVER PATIO DEAD WEIGHT


Total Length (Ft.) H (Ft.) AREA DL (PSF) WEIGHT [Lbs]
Trellis - - 90 5.0 450 Lbs
TOTAL ROOF DIAPHRAGM AREA 90 Sq.ft. 450 Lbs

92 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

TRELLIS
SEISMIC ANALYSIS BASED ON IBC 2012 (Equivalent Lateral-Force Procedure, ASCE 7-10 12.8)
INPUT DATA
Typical floor height h= 9.0 Ft.
Typical floor weight wx = 450 Lbs
Number of floors n= 1
Importance factor (ASCE 11.5.1) I= 1 (IBC Tab.1604.5)
Building location 247 20th Street, Santa Monica, CA 90405
Site class (A, B, C, D, E, F) D (If no soil report, use D)
The coefficient (ASCE Tab 12.8-2) Ct = 0.02
The coefficient(ASCE Tab. 12.2.1) R= 1.50
Seismic design category E
Latitude: 34.04 Longitude: -118.50
SS = 217.20 %g, Sms = 2.172 g , Fa = 1.0
S1 = 80.40 %g, Sm1 = 1.045 g , Fv = 1.3
SDS = 1.448 g, SD1 = 0.697 g
hn = 9 Ft k = 1.00 , (ASCE 12.8.3, pg 130)
x = 0.75 , (ASCE Tab 12.8-2) Ta = Ct (hn)x = 0.10 Sec, (ASCE 12.8.2.1)

W = 450 Lbs wxhk = 4,050

DESIGN SUMMARY
SD
V = Cs*W Cs = 0.97 V= 434 Lbs
E=V*ρ= E = 434,4 Lbs * ρ = 565 Lbs
ASD
V = Cs*W Cs = 0.97 V= 434 Lbs
E=V*ρ/1.4 E = 434,4Lbs. * ρ =/1.4= 395 Lbs

VERTICAL DISTRIBUTION OF LATERAL FORCES


Level Level Floor to Height Weight Lateral force
k
No. Name floor Height hx wx wxhx Cvx Fx Vx
Ft. Ft. Lbs Lbs Lbs
1 Roof 9.0 9.0 450 4,050 1.00 565 565

DIAPHRAGM FORCES
Level Fi W i Fpx Redundancy factor (ASCE 12.3.4)
Name Lbs Lbs Lbs ρ= 1.3
564.7 450 261

93 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

KNEE BRACE LATERAL LOAD DESIGN:

DESIGN LATERAL LOAD = 565 Lbs.

NUMBER OF POSTS= 2

LOAD PER POST= 282 Lbs./POST

F = 564,72 Lbs BEAM


0
2.0
P P
α B α = 45°
H 9 B

282 282

ΣMo = - H * 2ft. + 282lbs. * 9ft. = 0


B=H= 1269 Lbs.
P = H * √2 = 1795 Lbs.

USE: 2 5/8" ø LAG SCREWS


WITHDRAWAL VALUE ( ω) = 447 Lb/in * Per NDS 2015 Table 12.2A
EMBEDMENT ( p ω ) = 3 In.
∗ 447 Lbs./in x 3 in = 1341 Lbs.
2.16
Per NDS 2015 (LRFD): CM  1 Kf   3.32 z  0.65

W '  W  (C M  K f   z )  1341lbs. * 1 * 3,32 * 0,65 = 2897 Lbs.

LATERAL DESIGN VALUE: Zs  420 Lbs. * Per NDS 2010 Table 11J

Z '  Z s   (C M  K f   z )  420lbs. * 1 * 3,32 * 0,65 = 907 Lbs.

Z 'W ' 907,2lbs. * 2896,56lbs. = 1382 Lbs.


Z '  
Z ' sin 2
  W ' cos 2
 907,2lbs. * 0.5 + 2896,56lbs. * 0.5

N  Z '  2 * 1.382lbs. 2763 Lbs. > 1795 Lbs. OK

94 of 209
APPENDIX IV

IV.I - Wood Post Verification

95 of 209
Avila Structural Consultants, Inc
5315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91302 Engineer:  J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

POST VERIFICATION

P (Lbs) SEISMIC
H NOMINAL MIN. HOLDOWN Capacity
BM from LOAD TYPE MATERIAL Status
[ft] SECTION REQUIREMENT [Lbs.]
Enercalc E [Lib]

HDR102(1) 1900 0.0 9.0 C1 4x6 D.F.#2 NO HOLDOWN REQUIRED

HDR101(1) 710 0.0 9.0 C2 4x6 D.F.#2 NO HOLDOWN REQUIRED

HDR104(1) 5840 0.0 9.0 C3 4x6 D.F.#2 NO HOLDOWN REQUIRED

HDR104(1) 4960 0.0 9.0 C4 4x6 D.F.#2 NO HOLDOWN REQUIRED

HDR105(1) 4300 0.0 9.0 C5 4x6 D.F.#2 NO HOLDOWN REQUIRED

GT3(2) 4180 0.0 9.0 C6 4x6 D.F.#2 NO HOLDOWN REQUIRED

GT4(2) 3950 0.0 9.0 C7 4x6 D.F.#2 NO HOLDOWN REQUIRED

DBM202(1) 1330 0.0 10.0 C8 4x6 0 NO HOLDOWN REQUIRED

FBM202(2) 5540 1080.0 10.0 C9 4x6 0 NO HOLDOWN REQUIRED

HDR206(1) 2490 0.0 10.0 C10 4x6 0 NO HOLDOWN REQUIRED

FBM203(2) 3280 0.0 10.0 C11 4x6 0 NO HOLDOWN REQUIRED

FBM203(2) 3280 0.0 10.0 C12 4x6 0 NO HOLDOWN REQUIRED

HDR207(1) 7190 2570.0 10.0 C13 4x6 0 NO HOLDOWN REQUIRED

FBM205(2) 7140 660.0 10.0 C14 4x6 0 NO HOLDOWN REQUIRED

FBM216(1) 4710 1690.0 10.0 C15 4x6 0 NO HOLDOWN REQUIRED

HDR208(2) 330 0.0 10.0 C16 4x6 0 NO HOLDOWN REQUIRED

DBM204(2) 2810 340.0 10.0 C17 4x6 0 NO HOLDOWN REQUIRED

HDR205(2) 570 0.0 10.0 C18 4x6 0 NO HOLDOWN REQUIRED

FBM218(1) 2520 0.0 10.0 C19 4x6 0 NO HOLDOWN REQUIRED

FBM210(2) 5290 0.0 10.0 C20 4x6 0 NO HOLDOWN REQUIRED

DBM204(1) 4450 530.0 10.0 C21 4x6 0 NO HOLDOWN REQUIRED

DBM201(2) 1430 0.0 9.0 C22 4x6 0 NO HOLDOWN REQUIRED

FBM202(1) 7480 710.0 10.0 C23 4x6 0 NO HOLDOWN REQUIRED

FBM204(1) 7190 2570.0 10.0 C24 4x6 0 NO HOLDOWN REQUIRED

FBM204(2) 5300 0.0 10.0 C25 4x6 0 NO HOLDOWN REQUIRED

FBM207(2) 2310 0.0 10.0 C26 4x6 0 NO HOLDOWN REQUIRED

FBM208(1) 1750 0.0 10.0 C27 4x6 0 NO HOLDOWN REQUIRED

FBM213(1) 4330 0.0 10.0 C28 4x6 0 NO HOLDOWN REQUIRED

FBM209(2) 17620 3320.0 10.0 C29 6x6 0 NO HOLDOWN REQUIRED

HDR209(2) 10560 380.0 10.0 C30 4x6 0 NO HOLDOWN REQUIRED

DBM205(2) 7280 -650.0 10.0 C31 4x6 0 NO HOLDOWN REQUIRED

96 of 209
Avila Structural Consultants, Inc
5315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91302 Engineer:  J.I.S.
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

POST VERIFICATION

P (Lbs) SEISMIC
H NOMINAL MIN. HOLDOWN Capacity
BM from LOAD TYPE MATERIAL Status
[ft] SECTION REQUIREMENT [Lbs.]
Enercalc E [Lib]

FBM206(1) 11770 0.0 10.0 C32 6x6 0 NO HOLDOWN REQUIRED

HBM201(1) 1870 0.0 10.0 C33 4x6 0 NO HOLDOWN REQUIRED

DBM205(1) 8920 650.0 10.0 C34 6x6 0 NO HOLDOWN REQUIRED

HDR201(2) 410 0.0 10.0 C35 4x6 0 NO HOLDOWN REQUIRED

HDR204(2) 8020 480.0 10.0 C36 4x6 0 NO HOLDOWN REQUIRED

HDR204(1) 16230 1010.0 10.0 C37 6x6 0 NO HOLDOWN REQUIRED

HDR202(1) -470 50.0 10.0 C38 4x6 0 HDU2-SDS2.5 w/ 5/8" Thr. Rod 4305 OK

HDR202(2) -1940 140.0 10.0 C39 4x6 0 HDU2-SDS2.5 w/ 5/8" Thr. Rod 4305 OK

FBM209(1) 8300 -3320.0 10.0 C40 4x6 0 NO HOLDOWN REQUIRED

HDR203(1) 1640 0.0 10.0 C41 4x6 0 NO HOLDOWN REQUIRED

DBM203(1) 9560 0.0 10.0 C42 6x6 0 NO HOLDOWN REQUIRED

DBM203(2) 2640 0.0 10.0 C43 4x6 0 NO HOLDOWN REQUIRED

HDR209(1) 7000 160.0 10.0 C44 4x6 0 NO HOLDOWN REQUIRED

FBM304(1) 9790 1780.0 9.0 C45 6x6 0 NO HOLDOWN REQUIRED

FBM304(2) 7390 920.0 9.0 C46 4x6 0 NO HOLDOWN REQUIRED

FBM305(1) 5150 1400.0 9.0 C47 4x6 0 NO HOLDOWN REQUIRED

FBM305(2) 5540 1080.0 9.0 C48 4x6 0 NO HOLDOWN REQUIRED

97 of 209
Simpson Strong-Tie® Wood Construction Connectors

Post Allowable Loads


Post Allowable Compression Loads for Douglas Fir–Larch
Lumber Compression Parallel to Grain, Pc (100) Compression Parallel to Grain, Pc (160)
Perp. to
Framing Grain, Nominal Top-Plate Height (ft.) Nominal Top-Plate Height (ft.)
Size Grade Pc⊥
8 9 10 11 12 8 9 10 11 12

2x4 #2 3,280 3,170 2,565 2,105 1,755 1,485 3,345 2,665 2,170 1,795 1,510

3x4 #2 5,470 5,285 4,275 3,510 2,930 2,475 5,570 4,440 3,615 2,995 2,520

(2) 2x4 #2 6,565 6,340 5,130 4,215 3,515 2,970 6,685 5,330 4,335 3,590 3,020

4x4 #2 7,655 7,395 5,985 4,915 4,100 3,465 7,800 6,215 5,060 4,190 3,525
4-Inch
Wall
(3) 2x4 #2 9,845 9,510 7,695 6,320 5,270 4,455 10,030 7,995 6,505 5,390 4,535

4x6 #2 12,030 11,540 9,360 7,700 6,425 5,430 12,215 9,745 7,935 6,575 5,535

4x8 #2 15,860 15,090 12,270 10,105 8,440 7,140 16,035 12,805 10,435 8,650 7,285

4x10 #2 20,235 19,080 15,555 12,835 10,730 9,085 20,365 16,285 13,280 11,015 9,280

2x6 #2 5,155 8,970 7,940 6,935 6,025 5,235 11,030 9,230 7,740 6,535 5,575

3x6 #2 8,595 14,945 13,235 11,560 10,040 8,725 18,385 15,380 12,895 10,895 9,290

(2) 2x6 #2 10,315 17,935 15,885 13,875 12,050 10,470 22,060 18,455 15,475 13,075 11,145
6-Inch
4x6 #2 12,030 20,925 18,530 16,185 14,060 12,215 25,735 21,530 18,055 15,255 13,005
Wall
(3) 2x6 #2 15,470 26,905 23,825 20,810 18,075 15,705 33,090 27,685 23,215 19,610 16,720

6x6 #1 18,905 25,260 23,500 21,505 19,415 17,375 34,255 30,035 26,025 22,475 19,450

6x8 #1 25,780 34,450 32,045 29,320 26,475 23,690 46,715 40,955 35,485 30,645 26,520

Post Allowable Compression Loads for Southern Pine


Lumber Compression Parallel to Grain, Pc (100) Compression Parallel to Grain, Pc (160)
Perp. to
Framing Grain, Nominal Top-Plate Height (ft.) Nominal Top-Plate Height (ft.)
Size Grade Pc⊥
8 9 10 11 12 8 9 10 11 12

C-C-2017 © 2017 SIMPSON STRONG-TIE COMPANY INC.


2x4 #2 2,965 2,815 2,270 1,860 1,550 1,310 2,955 2,350 1,910 1,580 1,330

3x4 #2 4,945 4,690 3,785 3,105 2,585 2,180 4,920 3,920 3,185 2,635 2,220

(2) 2x4 #2 5,935 5,625 4,540 3,725 3,100 2,620 5,905 4,700 3,820 3,165 2,660

4x4 #2 6,920 6,565 5,295 4,345 3,615 3,055 6,890 5,485 4,460 3,690 3,105
4-Inch
Wall
(3) 2x4 #2 8,900 8,440 6,810 5,585 4,650 3,925 8,860 7,050 5,735 4,745 3,990

4x6 #2 10,875 10,260 8,295 6,810 5,675 4,790 10,800 8,600 6,995 5,795 4,875

4x8 #2 14,335 13,450 10,890 8,950 7,460 6,305 14,195 11,315 9,210 7,630 6,420

4x10 #2 18,290 17,055 13,835 11,380 9,495 8,030 18,055 14,405 11,730 9,720 8,180

2x6 #2 4,660 8,195 7,190 6,230 5,385 4,660 9,905 8,235 6,875 5,795 4,930

3x6 #2 7,770 13,655 11,980 10,385 8,975 7,765 16,510 13,725 11,460 9,655 8,220

(2) 2x6 #2 9,325 16,390 14,375 12,465 10,765 9,320 19,810 16,470 13,755 11,590 9,865
6-Inch
4x6 #2 10,875 19,120 16,775 14,540 12,560 10,875 23,115 19,215 16,045 13,520 11,505
Wall
(3) 2x6 #2 13,985 24,580 21,565 18,695 16,150 13,980 29,715 24,700 20,630 17,385 14,795

6x6 #1 17,090 21,495 20,270 18,835 17,260 15,655 30,025 26,820 23,595 20,610 17,975

6x8 #1 23,305 29,315 27,640 25,680 23,540 21,345 40,940 36,575 32,180 28,105 24,515

See footnotes on p. 385.

98 of 209
384
IV.II - Steel Column Calculation

99 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

SEISMIC LOADS: Cover Patio


Lower Roof DL: 10.5 lbs./sq.ft.
Ceiling DL: 6.0 lbs./sq.ft.

COVER PATIO DEAD WEIGHT


Total Length (Ft.) H (Ft.) AREA DL (PSF) WEIGHT [Lbs]
Lower Roof - - 75 10.5 788 Lbs
Ceiling - - 40 6.0 240 Lbs
TOTAL ROOF DIAPHRAGM AREA 75 Sq.ft. 1028 Lbs

100 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

COVER PATIO
SEISMIC ANALYSIS BASED ON IBC 2012 (Equivalent Lateral-Force Procedure, ASCE 7-10 12.8)
INPUT DATA
Typical floor height h= 9.0 Ft.
Typical floor weight wx = 1,028 Lbs
Number of floors n= 1
Importance factor (ASCE 11.5.1) I= 1 (IBC Tab.1604.5)
Building location 247 20th Street, Santa Monica, CA 90405
Site class (A, B, C, D, E, F) D (If no soil report, use D)
The coefficient (ASCE Tab 12.8-2) Ct = 0.02
The coefficient(ASCE Tab. 12.2.1) R= 1.25
Seismic design category E
Latitude: 34.04 Longitude: -118.50
SS = 217.20 %g, Sms = 2.172 g , Fa = 1.0
S1 = 80.40 %g, Sm1 = 1.045 g , Fv = 1.3
SDS = 1.448 g, SD1 = 0.697 g
hn = 9 Ft k = 1.00 , (ASCE 12.8.3, pg 130)
x = 0.75 , (ASCE Tab 12.8-2) Ta = Ct (hn)x = 0.10 Sec, (ASCE 12.8.2.1)

W = 1,028 Lbs wxhk = 9,248

DESIGN SUMMARY
SD
V = Cs*W Cs = 1.16 V= 1,190 Lbs
E=V*ρ= E = 1190,3 Lbs * ρ = 1,547 Lbs
ASD
V = Cs*W Cs = 1.16 V= 1,190 Lbs
E=V*ρ/1.4 E = 1190,3Lbs. * ρ =/1.4= 1,083 Lbs

VERTICAL DISTRIBUTION OF LATERAL FORCES


Level Level Floor to Height Weight Lateral force
k
No. Name floor Height hx wx wxhx Cvx Fx Vx
Ft. Ft. Lbs Lbs Lbs
1 Roof 9.0 9.0 1028 9,248 1.00 1,547 1,547

DIAPHRAGM FORCES
Level Fi W i Fpx Redundancy factor (ASCE 12.3.4)
Name Lbs Lbs Lbs ρ= 1.3
1,547.3 1,028 595

101 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

COVER PATIO
CANTILIVER COLUMN DESING
P
Lateral Force F = 1547 Lbs. F

Number of Columns = 2 Steel


H
Force per Column F1 = 1.547,3 / 2 = 774 Lbs. Columns

Axial Force Per Column P = 1,530 Lbs.*


*See beam reaction per Enercalc results. H= 9.0 ft
Column Ht. H =9 x 12 = 108 in

Bending Moment M1 = F1 x H =774 x 108 = 83.592 In.-Lbs.

Total Bending Moment = 83592 In.-Lbs.


Column Material = ASTM A500 Grade B
Column Yield Strength = 46,000 psi
Load Duration Factor = 1.6 Seismic
Compact Section = 0.66 AISC Manual Page 5-45 Equation (F1-1)
Allowable Bending Stress Fb =46000 x 1,6 x 0,66 = 48,576 psi
3
Section Modulus Required = M / Fball = 83592 / 48576 = 1.7 In.

Try : Square tube 4 x 4 x 1/4 Weight = 12.21 lb/ft


Actual Section Modulus S = 4.1 In.3 Moment of Inertia = 8.22 (in4)
Cross-Sectional Area A = 3.59 In.2 Rad. of Gyration (Least) = 1.51 in

Axial Compressive Stress fa = P/A = 1530 / 3.59 = 426.2 psi


Calculated Bending Stress fb = M / S = 83.592 / 4.11 = 20,339 psi
Deflection D1 = 1.4 x F1 x H1/3EI = 1.4 x 774 x 108 ^3 /(3 x 29000000 x 8.22) = 1.91 in

1.91 in
Allowable Compressive Stress Determination
K= 2.1 AISC Table C-C2.1 page 5-135
L= 108 Column Length in inches
KL/r = 2.1x 108/1.51 = 150.20
Allowable Compressive Stress Fa = 6,619 psi AISC Table 8, page 5-122

Ref. AISC Manual Chapter H Combined Stresses Page 5-55 Equation (H2-1)

fa/Fa + fb/Fb = 426.2 / 6,619 + 20,339 / 48576 = 0.48 < 1.0 OK

USE : Square tube 4 x 4 x 1/4

102 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

COVER PATIO
CHECK COLUMN DEFLECTION

Sx = Cd xe Ref. ASCE 7-10 EQN. (12.8-15) Page 92 Steel


Column
I

xe= 1.91 in
Cd = 1.25 Ref. Table 12.2-1 ASCE 7-10, Page 77 H
I= 1 Ref. Table 1.5-2 ASCE 7-10, Page 5
H= 108 Height of Column (inches)

Sx = 2.39 Maximum Inelastic Response


(Include Strength Level Force = 1.4 Factor)

Limit Sx 2.70 0.025*Story Height Table 12.12-1 ASCE 7-10, Page 97

Sx Limit Sx
2.39 < 2.70 OK

USE Column : Square tube 4 x 4 x 1/4

103 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : DBM202(2)

.
Code References
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Steel Section Name : HSS4x4x1/4 Overall Column Height 9 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top Free, Bottom Fixed
Steel Stress Grade Brace condition for deflection (buckling) along columns :
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 19,000.0 ksi Fully braced against buckling along X-X Axis
Y-Y (depth) axis :
Fully braced against buckling along Y-Y Axis

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 109.890 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 9.0 ft, D = 0.60, LR = 0.930 k
DESIGN SUMMARY .
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.01677 : 1 Maximum Load Reactions . .
Load Combination +1.20D+1.60Lr+0.50L+1.60H Top along X-X 0.0 k
Location of max.above base 0.0 ft Bottom along X-X 0.0 k
At maximum location values are . . . Top along Y-Y 0.0 k
Pu 2.340 k Bottom along Y-Y 0.0 k
0.9 * Pn 139.518 k
Mu-x Maximum Load Deflections . . .
0.0 k-ft
0.9 * Mn-x : 16.181 k-ft Along Y-Y 0.0 in at 0.0ft above base
for load combination :
Mu-y 0.0 k-ft
0.9 * Mn-y : 16.181 k-ft Along X-X 0.0 in at 0.0ft above base
for load combination :
PASS Maximum Shear Stress Ratio = 0.0 : 1
Load Combination 0.0
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 0.0 k
Vn * Phi : Allowable 0.0 k
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination Stress Ratio Status Location Stress Ratio Status Location
+1.40D+1.60H 0.007 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+1.60L+1.60H 0.009 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60L+0.50S+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50L+1.60H 0.017 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50W+1.60H 0.017 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+1.60S+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60S+0.50W+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+0.50L+W+1.60H 0.009 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.50S+W+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.20S+E+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+W+0.90H 0.005 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+E+0.90H 0.005 PASS 0.00 ft 0.000 PASS 0.00 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+H 0.710
+D+L+H 0.710

104 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : DBM202(2)

Maximum Reactions Note: Only non-zero reactions are listed.


Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+Lr+H 1.640
+D+S+H 0.710
+D+0.750Lr+0.750L+H 1.407
+D+0.750L+0.750S+H 0.710
+D+0.60W+H 0.710
+D+0.70E+H 0.710
+D+0.750Lr+0.750L+0.450W+H 1.407
+D+0.750L+0.750S+0.450W+H 0.710
+D+0.750L+0.750S+0.5250E+H 0.710
+0.60D+0.60W+0.60H 0.426
+0.60D+0.70E+0.60H 0.426
D Only 0.710
Lr Only 0.930
L Only
S Only
W Only
E Only
H Only
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 1.640
" Minimum
Reaction, X-X Axis Base Maximum 0.710
" Minimum 0.710
Reaction, Y-Y Axis Base Maximum 0.710
" Minimum 0.710
Reaction, X-X Axis Top Maximum 0.710
" Minimum 0.710
Reaction, Y-Y Axis Top Maximum 0.710
" Minimum 0.710
Moment, X-X Axis Base Maximum 0.710
" Minimum 0.710
Moment, Y-Y Axis Base Maximum 0.710
" Minimum 0.710
Moment, X-X Axis Top Maximum 0.710
" Minimum 0.710
Moment, Y-Y Axis Top Maximum 0.710
" Minimum 0.710

105 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : DBM202(2)

Sketches

106 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM213(2)

.
Code References
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Steel Section Name : Pipe6xS Overall Column Height 10.0 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top Free, Bottom Fixed
Steel Stress Grade Brace condition for deflection (buckling) along columns :
Fy : Steel Yield 36.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 19,000.0 ksi Unbraced Length for X-X Axis buckling = 10.0 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for Y-Y Axis buckling = 10.0 ft, K = 1.0

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 286.0 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 10.0 ft, D = 0.530, L = 0.390 k
DESIGN SUMMARY .
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.008026 : 1 Maximum Load Reactions . .
Load Combination +1.20D+0.50Lr+1.60L+1.60H Top along X-X 0.0 k
Location of max.above base 0.0 ft Bottom along X-X 0.0 k
At maximum location values are . . . Top along Y-Y 0.0 k
Pu 1.603 k Bottom along Y-Y 0.0 k
0.9 * Pn 199.748 k
Mu-x Maximum Load Deflections . . .
0.0 k-ft
0.9 * Mn-x : 42.120 k-ft Along Y-Y 0.0 in at 0.0ft above base
for load combination :
Mu-y 0.0 k-ft
0.9 * Mn-y : 42.120 k-ft Along X-X 0.0 in at 0.0ft above base
for load combination :
PASS Maximum Shear Stress Ratio = 0.0 : 1
Load Combination 0.0
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 0.0 k
Vn * Phi : Allowable 0.0 k
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination Stress Ratio Status Location Stress Ratio Status Location
+1.40D+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+1.60L+1.60H 0.008 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60L+0.50S+1.60H 0.008 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50L+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50W+1.60H 0.005 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+1.60S+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60S+0.50W+1.60H 0.005 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+0.50L+W+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.50S+W+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.20S+E+1.60H 0.006 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+W+0.90H 0.004 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+E+0.90H 0.004 PASS 0.00 ft 0.000 PASS 0.00 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+H 0.816
+D+L+H 1.206

107 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM213(2)

Maximum Reactions Note: Only non-zero reactions are listed.


Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+Lr+H 0.816
+D+S+H 0.816
+D+0.750Lr+0.750L+H 1.109
+D+0.750L+0.750S+H 1.109
+D+0.60W+H 0.816
+D+0.70E+H 0.816
+D+0.750Lr+0.750L+0.450W+H 1.109
+D+0.750L+0.750S+0.450W+H 1.109
+D+0.750L+0.750S+0.5250E+H 1.109
+0.60D+0.60W+0.60H 0.490
+0.60D+0.70E+0.60H 0.490
D Only 0.816
Lr Only
L Only 0.390
S Only
W Only
E Only
H Only
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 1.206
" Minimum
Reaction, X-X Axis Base Maximum 0.816
" Minimum 0.816
Reaction, Y-Y Axis Base Maximum 0.816
" Minimum 0.816
Reaction, X-X Axis Top Maximum 0.816
" Minimum 0.816
Reaction, Y-Y Axis Top Maximum 0.816
" Minimum 0.816
Moment, X-X Axis Base Maximum 0.816
" Minimum 0.816
Moment, Y-Y Axis Base Maximum 0.816
" Minimum 0.816
Moment, X-X Axis Top Maximum 0.816
" Minimum 0.816
Moment, Y-Y Axis Top Maximum 0.816
" Minimum 0.816

108 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM213(2)

Sketches

109 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM214(1)

.
Code References
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Steel Section Name : Pipe6xS Overall Column Height 10.0 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top Free, Bottom Fixed
Steel Stress Grade Brace condition for deflection (buckling) along columns :
Fy : Steel Yield 36.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 19,000.0 ksi Unbraced Length for X-X Axis buckling = 10.0 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for Y-Y Axis buckling = 10 ft, K = 1.0

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 286.0 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 10.0 ft, D = 7.870, LR = 3.280, L = 5.890, E = 0.940 k
DESIGN SUMMARY .
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.1044 : 1 Maximum Load Reactions . .
Load Combination +1.20D+0.50Lr+1.60L+1.60H Top along X-X 0.0 k
Location of max.above base 0.0 ft Bottom along X-X 0.0 k
At maximum location values are . . . Top along Y-Y 0.0 k
Pu 20.851 k Bottom along Y-Y 0.0 k
0.9 * Pn 199.748 k
Mu-x Maximum Load Deflections . . .
0.0 k-ft
0.9 * Mn-x : 42.120 k-ft Along Y-Y 0.0 in at 0.0ft above base
for load combination :
Mu-y 0.0 k-ft
0.9 * Mn-y : 42.120 k-ft Along X-X 0.0 in at 0.0ft above base
for load combination :
PASS Maximum Shear Stress Ratio = 0.0 : 1
Load Combination 0.0
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 0.0 k
Vn * Phi : Allowable 0.0 k
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination Stress Ratio Status Location Stress Ratio Status Location
+1.40D+1.60H 0.057 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+1.60L+1.60H 0.104 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60L+0.50S+1.60H 0.096 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50L+1.60H 0.090 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50W+1.60H 0.075 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+1.60S+1.60H 0.064 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60S+0.50W+1.60H 0.049 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+0.50L+W+1.60H 0.072 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.50S+W+1.60H 0.064 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.490D+0.50L+0.20S+2.540E+1.60H 0.088 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+W+0.90H 0.037 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.6104D+2.540E+0.90H 0.037 PASS 0.00 ft 0.000 PASS 0.00 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+H 8.156
+D+L+H 14.046

110 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM214(1)

Maximum Reactions Note: Only non-zero reactions are listed.


Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+Lr+H 11.436
+D+S+H 8.156
+D+0.750Lr+0.750L+H 15.034
+D+0.750L+0.750S+H 12.574
+D+0.60W+H 8.156
+D+0.70E+H 8.814
+D+0.750Lr+0.750L+0.450W+H 15.034
+D+0.750L+0.750S+0.450W+H 12.574
+D+0.750L+0.750S+0.5250E+H 13.067
+0.60D+0.60W+0.60H 4.894
+0.60D+0.70E+0.60H 5.552
D Only 8.156
Lr Only 3.280
L Only 5.890
S Only
W Only
E Only 0.940
H Only
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 15.034
" Minimum
Reaction, X-X Axis Base Maximum 8.156
" Minimum 8.156
Reaction, Y-Y Axis Base Maximum 8.156
" Minimum 8.156
Reaction, X-X Axis Top Maximum 8.156
" Minimum 8.156
Reaction, Y-Y Axis Top Maximum 8.156
" Minimum 8.156
Moment, X-X Axis Base Maximum 8.156
" Minimum 8.156
Moment, Y-Y Axis Base Maximum 8.156
" Minimum 8.156
Moment, X-X Axis Top Maximum 8.156
" Minimum 8.156
Moment, Y-Y Axis Top Maximum 8.156
" Minimum 8.156

111 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM214(1)

Sketches

112 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM308(3)

.
Code References
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Steel Section Name : HSS5-1/2x5-1/2x1/8 Overall Column Height 9.0 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top Pinned, Bottom Fixed
Steel Stress Grade Brace condition for deflection (buckling) along columns :
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 19,000.0 ksi Unbraced Length for X-X Axis buckling = 9.0 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for Y-Y Axis buckling = 9.0 ft, K = 1.0

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 81.090 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 9.0 ft, D = 19.040, LR = 3.130, L = 18.960, E = 1.530 k
DESIGN SUMMARY .
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.9056 : 1 Maximum Load Reactions . .
Load Combination +1.20D+0.50Lr+1.60L+1.60H Top along X-X 0.0 k
Location of max.above base 0.0 ft Bottom along X-X 0.0 k
At maximum location values are . . . Top along Y-Y 0.0 k
Pu 54.846 k Bottom along Y-Y 0.0 k
0.9 * Pn 60.562 k
Mu-x Maximum Load Deflections . . .
0.0 k-ft
0.9 * Mn-x : 11.982 k-ft Along Y-Y 0.0 in at 0.0ft above base
for load combination :
Mu-y 0.0 k-ft
0.9 * Mn-y : 11.982 k-ft Along X-X 0.0 in at 0.0ft above base
for load combination :
PASS Maximum Shear Stress Ratio = 0.0 : 1
Load Combination 0.0
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 0.0 k
Vn * Phi : Allowable 0.0 k
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination Stress Ratio Status Location Stress Ratio Status Location
+1.40D+1.60H 0.442 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+1.60L+1.60H 0.906 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60L+0.50S+1.60H 0.880 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50L+1.60H 0.618 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60Lr+0.50W+1.60H 0.462 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+1.60S+1.60H 0.535 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+1.60S+0.50W+1.60H 0.379 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50Lr+0.50L+W+1.60H 0.561 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.50S+W+1.60H 0.535 PASS 0.00 ft 0.000 PASS 0.00 ft
+1.20D+0.50L+0.20S+E+1.60H 0.561 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+W+0.90H 0.284 PASS 0.00 ft 0.000 PASS 0.00 ft
+0.90D+E+0.90H 0.309 PASS 0.00 ft 0.000 PASS 0.00 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+H 19.121
+D+L+H 38.081

113 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM308(3)

Maximum Reactions Note: Only non-zero reactions are listed.


Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+Lr+H 22.251
+D+S+H 19.121
+D+0.750Lr+0.750L+H 35.689
+D+0.750L+0.750S+H 33.341
+D+0.60W+H 19.121
+D+0.70E+H 20.192
+D+0.750Lr+0.750L+0.450W+H 35.689
+D+0.750L+0.750S+0.450W+H 33.341
+D+0.750L+0.750S+0.5250E+H 34.144
+0.60D+0.60W+0.60H 11.473
+0.60D+0.70E+0.60H 12.544
D Only 19.121
Lr Only 3.130
L Only 18.960
S Only
W Only
E Only 1.530
H Only
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 38.081
" Minimum
Reaction, X-X Axis Base Maximum 19.121
" Minimum 19.121
Reaction, Y-Y Axis Base Maximum 19.121
" Minimum 19.121
Reaction, X-X Axis Top Maximum 19.121
" Minimum 19.121
Reaction, Y-Y Axis Top Maximum 19.121
" Minimum 19.121
Moment, X-X Axis Base Maximum 19.121
" Minimum 19.121
Moment, Y-Y Axis Base Maximum 19.121
" Minimum 19.121
Moment, X-X Axis Top Maximum 19.121
" Minimum 19.121
Moment, Y-Y Axis Top Maximum 19.121
" Minimum 19.121

114 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
Steel Column ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : FBM308(3)

Sketches

115 of 209
APPENDIX V

Ledger Calculations

116 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Engineer: J.I.S.
Cell 818-489-4076 Date : 02/18/2018
www.AvilaEngineers.com

LOAD ESTIMATES
Trellis Dead Loads
2-3x6 T.J. @18" O.C. 4.0 lb/sq. ft.
Misc. 1.0 lb/sq. ft.
5.0 lb/sq. ft.
Trellis Live Loads
Trellis = 10.0 lb/sq. ft.

LEDGER ATTACHMENT CALCULATION - LINE 5

Trellis Dead Load:


DL = 5.0 psf P Trellis
Trellis Live Load: Wall
LR = 10 psf
Lag Screw
Tributary Width= 18 in Beam
Total area = 10ft /2 * 18in/12 = 7.5 sqft 2x Ledger

10 ft
P = (5psf + 10psf ) * 7.5sqft = 112.5 lbs.

USE (N) : 2 3/8" ø LAG SCREWS

Adjustment Factors
Wet Service Factor (CM) = 1
Temperature Factor (Ct) = 1
Incising Factor (Ci) = 0.8
Format Convert. Factor (KF) = 2.88
Resistance Factor (Ø) = 0.75
Time Effect Factor = 1

LATERAL DESIGN VALUE: Z s  140 Lbs. * Per NDS 2015 Table 12J

∅ 140lbs. * 1 * 1 * 0.8 * 2.88 * 0.75 * 1 = 242 Lbs.

N Z'  484 Lbs. > 113 Lbs. OK

117 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Engineer: J.I.S.
Cell 818-489-4076 Date : 02/18/2018
www.AvilaEngineers.com

LOAD ESTIMATES
Lower Roof Dead Loads
2x8 R.R. @16" O.C. 2.6 lb/sq. ft.
Metal Roofing 3.0 lb/sq. ft.
5/8" OSB Sheathing 3.2 lb/sq. ft.
Insulation 1.0 lb/sq. ft.
Misc. 0.7 lb/sq. ft.
10.5 lb/sq. ft.
Lower Roof Live Loads
Trellis = 40.0 lb/sq. ft.

LEDGER ATTACHMENT CALCULATION - LINE 1 & C

Trellis Dead Load:


DL = 10.5 psf P Roof
Trellis Live Load: Wall
LR = 10 psf
Lag Screw
Tributary Width= 36 in Beam
Total area = 5ft /2 * 36in/12 = 7.5 sqft 2x Ledger

5 ft
P = (10.5psf + 10psf ) * 7.5sqft = 153.75 lbs.

USE (N) : 2 1/4" ø LAG SCREWS

Adjustment Factors
Wet Service Factor (CM) = 1
Temperature Factor (Ct) = 1
Incising Factor (Ci) = 0.8
Format Convert. Factor (KF) = 2.88
Resistance Factor (Ø) = 0.75
Time Effect Factor = 1

LATERAL DESIGN VALUE: Z s  120 Lbs. * Per NDS 2015 Table 12J

∅ 120lbs. * 1 * 1 * 0.8 * 2.88 * 0.75 * 1 = 207 Lbs.

Z
N 415 Lbs. > 154 Lbs. OK

118 of 209
APPENDIX VI

VI.I - Footing Calculations

119 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

1 1) Roof
2 Trusses @ 24" O.C. 3.5
3 Metal Roofing 3.0
4 5/8" OSB Sheathing 3.2
5 Insulation 1.0
6 Misc. 1.8
7 Total 12.5 Lb/Sq.ft
8 2) Ceiling DL
9 2X6 C.J. @ 16" O.C. 2.1
10 5/8" Thick Drywall 3.2
11 Misc. 0.7
12 Total 6.0 Lb/Sq.ft
13 3) Floor DL
14 3/4" Plywood Sub Floor 3.0
15 5/8" Thick Drywall 3.2
16 Insulation 1.0
17 1.5" Concrete Light Weight 16.0
18 14" TJI @ 16 O.C. 3.2
19 Misc. 3.6
20 Total 30.0 Lb/Sq.ft
21 4) Ext. Wall DL
22 Studs 2X6 @ 16" O.C. 2.0
23 Stucco 10.0
24 1/2" OSB Sheathing 1.5
25 5/8" Thick Drywall 3.2
26 Insulation 1.0
27 Misc. 0.8
28 Total 18.5 Lb/Sq.ft
0
0
0
0
LIVE LOADS
Roof = 20.0 lb/sq.ft 5 Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft 6 er Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft 7 Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft 8 Bathroom = 40.0 lb/sq.ft

120 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

29 5) Int. Wall
30 Studs 2X6 @ 16" O.C. 2.0
31 1/2" OSB Sheathing 1.5
32 5/8" Thick Drywall 3.2
33 Insulation 1.0
34 Misc. 0.8
35 Total 8.5 Lb/Sq.ft
36 6) Trellis DL
37 2- 3x6 T.J. @18" O.C. 4.0
38 Misc. 1.0
39 Total 5.0 Lb/Sq.ft
40 7) Lower Roof DL
41 2x8 R.R. @16" O.C. 2.6
42 Metal Roofing 3.0
43 5/8" OSB Sheathing 3.2
44 Insulation 1.0
45 Misc. 0.7
46 Total 10.5 Lb/Sq.ft
47 8) Brick Veneer Ext. Wall DL
48 2x6 Studs @ 16" O.C. 1.5
49 1/2" Thick Interior Dry Wall 1.5
50 5/8" Thick Interior Dry Wall 3.2
51 Brick Veneer 14.0
52 Insulation 1.0
53 Misc. 0.8
54 Total 22.0 Lb/Sq.ft
0
0
0
0
0
0
LIVE LOADS
Roof = 20.0 lb/sq.ft Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft Brick Veneer Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft Bathroom = 40.0 lb/sq.ft

121 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

LOAD ESTIMATES
DEAD LOADS

55 9) Deck
56 2" Concrete Light Weight 16.0
57 1 1/8" CDX Plywood 3.5
58 2x12 @16" O.C. 3.2
59 5/8" Thick Dry Wall 3.2
60 Misc. 0.6
61 Total 26.5 Lb/Sq.ft
62 10) Bathroom DL
63 3/4" Plywood Sub Floor 2.1
64 Tile 10.0
65 1 1/2" Leveling Concret 12.0
66 5/8" Thick Dry Wall 3.2
67 2x12 @16" O.C. 3.9
68 Misc. 0.8
69 Insulation 1.0
70 Total 33.0 Lb/Sq.ft
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
LIVE LOADS
Roof = 20.0 lb/sq.ft Lower Roof = 20.0 lb/sq.ft
Ceiling = 10.0 lb/sq.ft Brick Veneer Ext. Wall = 0.0 lb/sq.ft
Floor = 40.0 lb/sq.ft Deck = 40.0 lb/sq.ft
Trellis = 10.0 lb/sq.ft Bathroom = 40.0 lb/sq.ft

122 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

FOOTING CALCULATION - LINE 3 & 4

Roof Tributary Width = 1.3 Ft. 1.33 ft.


Roof DL= 12.5 Lbs/Sq. Ft.
ROOF
Roof LR= 20.0 Lbs/Sq. Ft.
1.33 ft. 9.00 ft.
2nd Floor Tribut. Width = 1.3 Ft. 2nd FLOOR
Floor DL= 30.0 Lbs/Sq. Ft. 1.33 ft. 10.00 ft.
Floor LL= 40.0 Lbs/Sq. Ft. 1st FLOOR
RW 9.00 ft.
1st Floor Tribut. Width = 1.3 Ft.
Floor DL= 30.0 Lbs/Sq. Ft. FOUNDATION
Floor LL= 40.0 Lbs/Sq. Ft.

Stucco Wall Height = 9.0 Ft.


Wall DL= 18.5 Lbs/Sq. Ft.

Brick Veneer Wall Height = 10.0 Ft.


Wall DL= 22.0 Lbs/Sq. Ft.

TOTAL LOAD
PDL= 483 Lbs/ Ft.
PLR= 27 Lbs/ Ft.
PLL= 106 Lbs/ Ft.

Soils Values Design Size Footing


Soil Bearing Capacity1,2 2000 psf Width 1.25 ft
Passive2 300 pcf Depth 2.0 ft
Friction2 0.26 Final Bearing Capacity 2000 psf

P
W (ft)
*per Soils Report page 9-10
1
Maximum safe soil bearing pressure 3000 psf.
2
These values may be increased by 1/3 for sind or seismic loading. L (ft)

AREA (A)

P (Lbs/Ft) W (FT) L (FT) σ=P/A (pcf)


WxL
(SQ.FT)
Cont.
Footing
616 1.25 1.0 1.25 493 < 2000 OK

123 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

FOOTING CALCULATION - LINE B

1st Floor Tribut. Width = 8.5 Ft.


Floor DL= 30.0 Lbs/Sq. Ft. 7.50 ft. 8.50 ft.
Floor LL= 40.0 Lbs/Sq. Ft. 1st FLOOR
WALL 9.00 ft.
TOTAL LOAD
PDL= 255 Lbs/ Ft. FOUNDATION
PLL= 340 Lbs/ Ft.

Soils Values Design Size Footing


Soil Bearing Capacity1,2 2000 psf Width 1.25 ft
Passive2 350 pcf Depth 2.0 ft
2
Friction 0.40 Final Bearing Capacity 2000 psf

P
W (ft)
*per Soils Report page 9-10
1
Maximum safe soil bearing pressure 3000 psf.
2
These values may be increased by 1/3 for sind or seismic loading. L (ft)

AREA (A)

P (Lbs/Ft) W (FT) L (FT) σ=P/A (pcf)


WxL
(SQ.FT)
Cont.
Footing
595 1.25 1.0 1.25 476 < 2000 OK

124 of 209
Avila Structural Consultants, Inc
15315 Magnolia Blvd. #429 Project: Santa Monica
Sherman Oaks, CA 91403 Enginner: J.I.S.
Cell 818-489-4076 Date : 03/11/2018
www.AvilaEngineers.com

FOOTING CALCULATION - LINE C

Roof Tributary Width = 6.5 Ft. 6.50 ft.


Roof DL= 12.5 Lbs/Sq. Ft.
ROOF
Roof LR= 20.0 Lbs/Sq. Ft.
1.33 ft. 9.00 ft.
2nd Floor Tribut. Width = 1.3 Ft. 2nd FLOOR
Floor DL= 30.0 Lbs/Sq. Ft. 7.50 ft. 10.00 ft.
Floor LL= 40.0 Lbs/Sq. Ft. 1st FLOOR
RW 9.00 ft.
1st Floor Tribut. Width = 7.5 Ft.
Floor DL= 30.0 Lbs/Sq. Ft. FOUNDATION
Floor LL= 40.0 Lbs/Sq. Ft.

Stucco Wall Height = 9.0 Ft.


Wall DL= 18.5 Lbs/Sq. Ft.

Brick Veneer Wall Height = 10.0 Ft.


Wall DL= 22.0 Lbs/Sq. Ft.

TOTAL LOAD
PDL= 733 Lbs/ Ft.
PLR= 130 Lbs/ Ft.
PLL= 353 Lbs/ Ft.

Soils Values Design Size Footing


Soil Bearing Capacity1,2 2000 psf Width 1.25 ft
Passive2 300 pcf Depth 2.0 ft
Friction2 0.26 Final Bearing Capacity 2000 psf

P
W (ft)
*per Soils Report page 9-10
1
Maximum safe soil bearing pressure 3000 psf.
2
These values may be increased by 1/3 for sind or seismic loading. L (ft)

AREA (A)

P (Lbs/Ft) W (FT) L (FT) σ=P/A (pcf)


WxL
(SQ.FT)
Cont.
Footing
1216 1.25 1.0 1.25 973 < 2000 OK

125 of 209
VI.II - Pad Requirement

126 of 209
Avila Structural Consultants, Inc
5315 Magnolia Blvd. #429  Project: Santa Monica
Sherman Oaks, CA 91302 Engineer:  J.I.S.
0
Cell 818‐489‐4076 Date :  03/11/2018
www.AvilaEngineers.com

PAD REQUIREMENT

Soil Bearing Capacity= 2000 Psf.

P (Lbs) AREA (A) Soil PAD NUMBER


H W
BM from
[ft] [ft]
L(FT) (2*H) WxL σ=P/A (pcf) Bearing STATUS SEE
Enercalc Capacity  ENERCALC
(SQ.FT)
FBM218(1)
PAD NOT
+ 5320 2.0 1.3 4.0 5.0 1064.0 < 2000
NEEDED
FBM307(1)
FBM218(2)
PAD NOT
+ 4680 2.0 1.3 4.0 5.0 936.0 < 2000
NEEDED
FBM307(2)
FBM204(2)
PAD
+ 16220 2.0 1.3 4.0 5.0 3244.0 > 2000
NEEDED
F1
FBM308(2)
PAD
FBM308(3) 41130 2.0 1.3 4.0 5.0 8226.0 > 2000
NEEDED
F2

PAD
FBM308(4) 23320 2.0 1.3 4.0 5.0 4664.0 > 2000
NEEDED
F3

PAD NOT
FBM213(2) 920 2.0 1.3 4.0 5.0 184.0 < 2000
NEEDED
PAD
FBM214(1) 17040 2.0 1.3 4.0 5.0 3408.0 > 2000
NEEDED
F4

FBM304(1)
PAD NOT
+ 9790 2.0 1.3 4.0 5.0 1958.0 < 2000
NEEDED
HDR301(2)
PAD NOT
FBM304(2) 7390 2.0 1.3 4.0 5.0 1478.0 < 2000
NEEDED
HDR203(1)
PAD NOT
+ 5150 2.0 1.3 4.0 5.0 1030.0 < 2000
NEEDED
FBM305(1)
PAD NOT
FBM305(2) 5540 2.0 1.3 4.0 5.0 1108.0 < 2000
NEEDED
PAD NOT
DBM203(1) 9560 2.0 1.3 4.0 5.0 1912.0 < 2000
NEEDED

127 of 209
VI.III - Pad Calculations

128 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F1] - FBM204(2) + FBM307(1)

Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.0 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 300.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.260
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No = ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 3.250 ft
Length parallel to Z-Z Axis = 3.250 ft
Footing Thickness = 18 in

Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
Height = in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in

Reinforcing
Bars parallel to X-X Axis
Number of Bars = 5
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 5
Reinforcing Bar Size = # 5

Bandwidth Distribution Check (ACI 15.4.4.2)


Direction Requiring Closer Separation n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 7.920 0.350 7.950 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k

129 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F1] - FBM204(2) + FBM307(1)

DESIGN SUMMARY Design OK


Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.860 Soil Bearing 1.720 ksf 2.0 ksf +D+L+H about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.09035 Z Flexure (+X) 2.80 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09035 Z Flexure (-X) 2.80 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09035 X Flexure (+Z) 2.80 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09035 X Flexure (-Z) 2.80 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.06126 1-way Shear (+X) 4.595 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.06126 1-way Shear (-X) 4.595 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.06126 1-way Shear (+Z) 4.595 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.06126 1-way Shear (-Z) 4.595 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.1420 2-way Punching 21.294 psi 150.0 psi +1.20D+0.50Lr+1.60L+1.60H

130 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F2] - FBM308(3)

Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.0 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 300.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.260
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No = ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 4.750 ft
Length parallel to Z-Z Axis = 4.750 ft
Footing Thickness = 18.0 in

Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
Height = in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in

Reinforcing
Bars parallel to X-X Axis
Number of Bars = 6
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 6
Reinforcing Bar Size = # 5

Bandwidth Distribution Check (ACI 15.4.4.2)


Direction Requiring Closer Separation n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 19.040 3.130 18.960 1.530 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k

131 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F2] - FBM308(3)

DESIGN SUMMARY Design OK


Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.9510 Soil Bearing 1.902 ksf 2.0 ksf +D+L+H about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.2671 Z Flexure (+X) 6.844 k-ft/ft 25.620 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2671 Z Flexure (-X) 6.844 k-ft/ft 25.620 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2671 X Flexure (+Z) 6.844 k-ft/ft 25.620 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2671 X Flexure (-Z) 6.844 k-ft/ft 25.620 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2049 1-way Shear (+X) 15.368 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2049 1-way Shear (-X) 15.368 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2049 1-way Shear (+Z) 15.368 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.2049 1-way Shear (-Z) 15.368 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.3781 2-way Punching 56.720 psi 150.0 psi +1.20D+0.50Lr+1.60L+1.60H

132 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F3] - FBM308(4)

Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.0 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 300.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.260
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No = ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 3.750 ft
Length parallel to Z-Z Axis = 3.750 ft
Footing Thickness = 18.0 in

Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
Height = in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in

Reinforcing
Bars parallel to X-X Axis
Number of Bars = 5
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 5
Reinforcing Bar Size = # 5

Bandwidth Distribution Check (ACI 15.4.4.2)


Direction Requiring Closer Separation n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 10.94 3.380 9.0 1.650 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k

133 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F3] - FBM308(4)

DESIGN SUMMARY Design OK


Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.8280 Soil Bearing 1.656 ksf 2.0 ksf +D+0.750Lr+0.750L+0.450W+H about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.1353 Z Flexure (+X) 3.652 k-ft/ft 26.996 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.1353 Z Flexure (-X) 3.652 k-ft/ft 26.996 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.1353 X Flexure (+Z) 3.652 k-ft/ft 26.996 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.1353 X Flexure (-Z) 3.652 k-ft/ft 26.996 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09812 1-way Shear (+X) 7.359 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09812 1-way Shear (-X) 7.359 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09812 1-way Shear (+Z) 7.359 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.09812 1-way Shear (-Z) 7.359 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.1914 2-way Punching 28.712 psi 150.0 psi +1.20D+0.50Lr+1.60L+1.60H

134 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F4] - FBM214(1)

Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.0 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 300.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.260
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No = ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 3.25 ft
Length parallel to Z-Z Axis = 3.250 ft
Footing Thickness = 18.0 in

Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
Height = in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in

Reinforcing
Bars parallel to X-X Axis
Number of Bars = 5.0
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 5.0
Reinforcing Bar Size = # 5

Bandwidth Distribution Check (ACI 15.4.4.2)


Direction Requiring Closer Separation n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 7.870 3.280 5.890 0.940 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k

135 of 209
Avila Structural Consultants, Inc Project Title: Santa Monica
5315 Magnolia Blvd. #429 Engineer: J.I.S. Project ID:
Sherman Oaks, CA 91302 Project Descr: New Residence
Cell 818-489-4076
www.AvilaEngineers.com

File = C:\Users\D5\Desktop\ENERCA~3.EC6
General Footing ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Lic. # : KW-06005934 Licensee : GED
Description : [F4] - FBM214(1)

DESIGN SUMMARY Design OK


Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.8070 Soil Bearing 1.614 ksf 2.0 ksf +D+0.750Lr+0.750L+0.450W+H about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.08273 Z Flexure (+X) 2.564 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.08273 Z Flexure (-X) 2.564 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.08273 X Flexure (+Z) 2.564 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.08273 X Flexure (-Z) 2.564 k-ft/ft 30.988 k-ft/ft +1.20D+0.50Lr+1.60L+1.60H
PASS 0.05609 1-way Shear (+X) 4.207 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.05609 1-way Shear (-X) 4.207 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.05609 1-way Shear (+Z) 4.207 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.05609 1-way Shear (-Z) 4.207 psi 75.0 psi +1.20D+0.50Lr+1.60L+1.60H
PASS 0.130 2-way Punching 19.496 psi 150.0 psi +1.20D+0.50Lr+1.60L+1.60H

136 of 209
VI.IV – Retaining Wall Calculations

137 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,134.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 6.50 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 5.50 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 1,138.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 1,050.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 2.01 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 7,964 lbs Rebar Size = # 6
...resultant ecc. = 9.95 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,547 psf OK Design Data
Soil Pressure @ Heel = 383 psf OK fb/FB + fa/Fa = 0.908
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,166 psf
ACI Factored @ Heel = 537 psf Strength Level lbs = 5,022.0
Moment....Actual
Footing Shear @ Toe = 34.8 psi OK
Service Level ft-# =
Footing Shear @ Heel = 11.9 psi OK
Strength Level ft-# = 18,468.0
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 4,441.5 lbs
Service Level psi =
Strength Level psi = 54.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

138 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.5617 in2/ft
(4/3) * As : 0.7489 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.5617 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,166 537 psf
Total Footing Width = 8.25 Mu' : Upward = 25,087 1,595 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 21,366 2,563 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 34.77 11.89 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 5 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.38 in, #5@ 8.33 in, #6@ 11.83 in, #7@ 16.13 in, #8@ 21.24 in, #9@ 26.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,134.0 7.50 8,505.0 Axial Dead Load on Stem = 1,138.0 5.67 6,448.7
Load @ Stem Above Soil = * Axial Live Load on Stem = 1,050.0 5.67 5,950.0
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,441.5 O.T.M. 20,081.3
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 2.01 Key Weight =
Vertical Loads used for Soil Pressure = 7,963.5 lbs Vert. Component =
Total = 6,913.5 lbs R.M. = 40,380.5
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

139 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.050 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

140 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

141 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

142 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 1,138.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 1,050.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 3.49 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 7,964 lbs Rebar Size = # 6
...resultant ecc. = 2.87 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 797 psf OK Design Data
Soil Pressure @ Heel = 1,133 psf OK fb/FB + fa/Fa = 0.574
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 1,116 psf
ACI Factored @ Heel = 1,586 psf Strength Level lbs = 3,888.0
Moment....Actual
Footing Shear @ Toe = 22.3 psi OK
Service Level ft-# =
Footing Shear @ Heel = 2.9 psi OK
Strength Level ft-# = 11,664.0
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 3,307.5 lbs
Service Level psi =
Strength Level psi = 42.5
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

143 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.3548 in2/ft
(4/3) * As : 0.473 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.3548 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 1,116 1,586 psf
Total Footing Width = 8.25 Mu' : Upward = 16,758 3,902 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 13,037 255 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 22.33 2.87 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem = 1,138.0 5.67 6,448.7
Load @ Stem Above Soil = * Axial Live Load on Stem = 1,050.0 5.67 5,950.0
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 3,307.5 O.T.M. 11,576.3
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 3.49 Key Weight =
Vertical Loads used for Soil Pressure = 7,963.5 lbs Vert. Component =
Total = 6,913.5 lbs R.M. = 40,380.5
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

144 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.050 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

145 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

146 of 209
Avila Structural Consultants, Inc Title R.W. #1 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

147 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 8.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 1.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 896.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 5.83 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 4.83 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 679.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 446.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Mononobe-Okabe/Seed-Whitman Kae for seismic earth pressure = 0.675 Added seismic base force 1,280.0 lbs
KaDifference: Kaepressure
for static earth - Ka = 0.383
Design Kh = 0.290 g
= 0.292
Using Mononobe-Okabe / Seed-Whitman procedure

148 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.62 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,599 lbs Rebar Size = # 6
...resultant ecc. = 20.12 in Rebar Spacing = 6.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,797 psf OK Design Data
Soil Pressure @ Heel = 0 psf OK fb/FB + fa/Fa = 0.807
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,515 psf
ACI Factored @ Heel = 0 psf Strength Level lbs = 5,653.7
Moment....Actual
Footing Shear @ Toe = 36.1 psi OK
Service Level ft-# =
Footing Shear @ Heel = 17.2 psi OK
Strength Level ft-# = 21,059.2
Allowable = 75.0 psi
Moment.....Allowable = 26,082.9
Sliding Calcs
Lateral Sliding Force = 4,883.5 lbs
Service Level psi =
Strength Level psi = 61.8
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

149 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.6405 in2/ft
(4/3) * As : 0.854 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.6405 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.88 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,515 0 psf
Total Footing Width = 8.25 Mu' : Upward = 26,408 115 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 3,766 ft-#
Mu: Design = 22,687 3,651 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 36.08 17.22 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.06 in, #5@ 7.85 in, #6@ 11.14 in, #7@ 15.19 in, #8@ 20.00 in, #9@ 25.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 2,707.5 3.17 8,573.8 Soil Over Heel = 2,409.3 7.17 17,266.9
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 896.0 6.83 6,119.7 Axial Dead Load on Stem = 679.0 5.67 3,847.7
Load @ Stem Above Soil = * Axial Live Load on Stem = 446.0 5.67 2,527.3
Seismic Earth Load = 1,280.0 5.70 7,296.1 Soil Over Toe =
= Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,883.5 O.T.M. 21,989.5
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 1.62 Key Weight =
Vertical Loads used for Soil Pressure = 6,599.3 lbs Vert. Component =
Total = 6,153.3 lbs R.M. = 35,621.2
If seismic is included, the OTM and sliding ratios * Axial live load NOT included in total displayed, or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

150 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.059 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

151 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

152 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Seismic Page : 6
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

153 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11
License To : GED

Criteria Soil Data


Retained Height = 8.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 1.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 679.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 446.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Mononobe-Okabe/Seed-Whitman Kae for seismic earth pressure = 0.675 Added seismic base force 1,280.0 lbs
KaDifference: Kaepressure
for static earth - Ka = 0.383
Design Kh = 0.290 g
= 0.292
Using Mononobe-Okabe / Seed-Whitman procedure

154 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11
License To : GED

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 2.24 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,599 lbs Rebar Size = # 6
...resultant ecc. = 8.99 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,236 psf OK Design Data
Soil Pressure @ Heel = 364 psf OK fb/FB + fa/Fa = 0.801
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 1,730 psf
ACI Factored @ Heel = 510 psf Strength Level lbs = 4,757.7
Moment....Actual
Footing Shear @ Toe = 27.0 psi OK
Service Level ft-# =
Footing Shear @ Heel = 10.9 psi OK
Strength Level ft-# = 16,283.6
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 3,987.5 lbs
Service Level psi =
Strength Level psi = 52.0
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2012,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

155 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.4953 in2/ft
(4/3) * As : 0.6604 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.4953 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 1,730 510 psf
Total Footing Width = 8.25 Mu' : Upward = 20,274 1,447 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 3,766 ft-#
Mu: Design = 16,554 2,319 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 26.97 10.88 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 2,707.5 3.17 8,573.8 Soil Over Heel = 2,409.3 7.17 17,266.9
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem = 679.0 5.67 3,847.7
Load @ Stem Above Soil = * Axial Live Load on Stem = 446.0 5.67 2,527.3
Seismic Earth Load = 1,280.0 5.70 7,296.1 Soil Over Toe =
= Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 3,987.5 O.T.M. 15,869.8
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 2.24 Key Weight =
Vertical Loads used for Soil Pressure = 6,599.3 lbs Vert. Component =
Total = 6,153.3 lbs R.M. = 35,621.2
If seismic is included, the OTM and sliding ratios * Axial live load NOT included in total displayed, or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

156 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.040 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

157 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11
License To : GED

158 of 209
Avila Structural Consultants, Inc Title R.W. #2 : - Static Page : 6
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11
License To : GED

159 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,134.0 #/ft Adjacent Footing Load = 3,000.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 5.90 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 4.90 ft Eccentricity = -12.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 730.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 680.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.96 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 7,186 lbs Rebar Size = # 6
...resultant ecc. = 11.89 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,499 psf OK Design Data
Soil Pressure @ Heel = 243 psf OK fb/FB + fa/Fa = 0.875
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,098 psf
ACI Factored @ Heel = 341 psf Strength Level lbs = 5,022.0
Moment....Actual
Footing Shear @ Toe = 32.5 psi OK
Service Level ft-# =
Footing Shear @ Heel = 14.0 psi OK
Strength Level ft-# = 17,787.6
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 4,441.5 lbs
Service Level psi =
Strength Level psi = 54.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

160 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.541 in2/ft
(4/3) * As : 0.7214 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.541 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,098 341 psf
Total Footing Width = 8.25 Mu' : Upward = 23,776 1,161 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 20,055 2,997 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 32.46 13.98 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.73 in, #5@ 8.88 in, #6@ 12.60 in, #7@ 17.18 in, #8@ 22.62 in, #9@ 28.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,134.0 6.90 7,824.6 Axial Dead Load on Stem = 730.0 5.67 4,136.7
Load @ Stem Above Soil = * Axial Live Load on Stem = 680.0 5.67 3,853.3
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,441.5 O.T.M. 19,400.9
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 1.96 Key Weight =
Vertical Loads used for Soil Pressure = 7,185.5 lbs Vert. Component =
Total = 6,505.5 lbs R.M. = 38,068.5
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

161 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.049 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

162 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

163 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

164 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,134.0 #/ft Adjacent Footing Load = 3,000.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 5.90 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 4.90 ft Eccentricity = -12.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 730.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 680.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.96 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 7,186 lbs Rebar Size = # 6
...resultant ecc. = 11.89 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,499 psf OK Design Data
Soil Pressure @ Heel = 243 psf OK fb/FB + fa/Fa = 0.875
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,098 psf
ACI Factored @ Heel = 341 psf Strength Level lbs = 5,022.0
Moment....Actual
Footing Shear @ Toe = 32.5 psi OK
Service Level ft-# =
Footing Shear @ Heel = 14.0 psi OK
Strength Level ft-# = 17,787.6
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 4,441.5 lbs
Service Level psi =
Strength Level psi = 54.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

165 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.541 in2/ft
(4/3) * As : 0.7214 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.541 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,098 341 psf
Total Footing Width = 8.25 Mu' : Upward = 23,776 1,161 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 20,055 2,997 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 32.46 13.98 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.73 in, #5@ 8.88 in, #6@ 12.60 in, #7@ 17.18 in, #8@ 22.62 in, #9@ 28.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,134.0 6.90 7,824.6 Axial Dead Load on Stem = 730.0 5.67 4,136.7
Load @ Stem Above Soil = * Axial Live Load on Stem = 680.0 5.67 3,853.3
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,441.5 O.T.M. 19,400.9
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 1.96 Key Weight =
Vertical Loads used for Soil Pressure = 7,185.5 lbs Vert. Component =
Total = 6,505.5 lbs R.M. = 38,068.5
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

166 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.049 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

167 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

168 of 209
Avila Structural Consultants, Inc Title R.W. #3 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

169 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,134.0 #/ft Adjacent Footing Load = 3,000.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 5.90 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 4.90 ft Eccentricity = -12.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 300.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 106.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.84 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,182 lbs Rebar Size = # 6
...resultant ecc. = 16.83 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,513 psf OK Design Data
Soil Pressure @ Heel = 0 psf OK fb/FB + fa/Fa = 0.875
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,119 psf
ACI Factored @ Heel = 0 psf Strength Level lbs = 5,022.0
Moment....Actual
Footing Shear @ Toe = 30.8 psi OK
Service Level ft-# =
Footing Shear @ Heel = 17.6 psi OK
Strength Level ft-# = 17,787.6
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 4,441.5 lbs
Service Level psi =
Strength Level psi = 54.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

170 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.541 in2/ft
(4/3) * As : 0.7214 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.541 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,119 0 psf
Total Footing Width = 8.25 Mu' : Upward = 22,945 392 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 19,224 3,765 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 30.77 17.60 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.98 in, #5@ 9.26 in, #6@ 13.15 in, #7@ 17.93 in, #8@ 23.60 in, #9@ 29.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,134.0 6.90 7,824.6 Axial Dead Load on Stem = 300.0 5.67 1,700.0
Load @ Stem Above Soil = * Axial Live Load on Stem = 106.0 5.67 600.7
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,441.5 O.T.M. 19,400.9
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 1.84 Key Weight =
Vertical Loads used for Soil Pressure = 6,181.5 lbs Vert. Component =
Total = 6,075.5 lbs R.M. = 35,631.9
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

171 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.049 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

172 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

173 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

174 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,134.0 #/ft Adjacent Footing Load = 3,000.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 5.90 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 4.90 ft Eccentricity = -12.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 300.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 106.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.84 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,182 lbs Rebar Size = # 6
...resultant ecc. = 16.83 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,513 psf OK Design Data
Soil Pressure @ Heel = 0 psf OK fb/FB + fa/Fa = 0.875
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,119 psf
ACI Factored @ Heel = 0 psf Strength Level lbs = 5,022.0
Moment....Actual
Footing Shear @ Toe = 30.8 psi OK
Service Level ft-# =
Footing Shear @ Heel = 17.6 psi OK
Strength Level ft-# = 17,787.6
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 4,441.5 lbs
Service Level psi =
Strength Level psi = 54.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

175 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.541 in2/ft
(4/3) * As : 0.7214 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.541 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,119 0 psf
Total Footing Width = 8.25 Mu' : Upward = 22,945 392 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 19,224 3,765 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 30.77 17.60 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.98 in, #5@ 9.26 in, #6@ 13.15 in, #7@ 17.93 in, #8@ 23.60 in, #9@ 29.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,134.0 6.90 7,824.6 Axial Dead Load on Stem = 300.0 5.67 1,700.0
Load @ Stem Above Soil = * Axial Live Load on Stem = 106.0 5.67 600.7
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,441.5 O.T.M. 19,400.9
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 1.84 Key Weight =
Vertical Loads used for Soil Pressure = 6,181.5 lbs Vert. Component =
Total = 6,075.5 lbs R.M. = 35,631.9
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

176 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.049 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

177 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

178 of 209
Avila Structural Consultants, Inc Title R.W. #4 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

179 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,340.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 6.50 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 5.50 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 300.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 400.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.65 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,476 lbs Rebar Size = # 6
...resultant ecc. = 19.35 in Rebar Spacing = 6.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,718 psf OK Design Data
Soil Pressure @ Heel = 0 psf OK fb/FB + fa/Fa = 0.755
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,405 psf
ACI Factored @ Heel = 0 psf Strength Level lbs = 5,228.0
Moment....Actual
Footing Shear @ Toe = 34.6 psi OK
Service Level ft-# =
Footing Shear @ Heel = 18.8 psi OK
Strength Level ft-# = 19,704.0
Allowable = 75.0 psi
Moment.....Allowable = 26,082.9
Sliding Calcs
Lateral Sliding Force = 4,647.5 lbs
Service Level psi =
Strength Level psi = 57.1
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

180 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.5993 in2/ft
(4/3) * As : 0.7991 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.5993 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.88 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,405 0 psf
Total Footing Width = 8.25 Mu' : Upward = 25,451 164 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 21,730 3,993 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 34.62 18.82 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.29 in, #5@ 8.19 in, #6@ 11.63 in, #7@ 15.86 in, #8@ 20.88 in, #9@ 26.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,340.0 7.50 10,050.0 Axial Dead Load on Stem = 300.0 5.67 1,700.0
Load @ Stem Above Soil = * Axial Live Load on Stem = 400.0 5.67 2,266.7
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 4,647.5 O.T.M. 21,626.3
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 1.65 Key Weight =
Vertical Loads used for Soil Pressure = 6,475.5 lbs Vert. Component =
Total = 6,075.5 lbs R.M. = 35,631.9
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

181 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.056 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

182 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

183 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

184 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 300.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 400.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 3.08 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,476 lbs Rebar Size = # 6
...resultant ecc. = 0.72 in Rebar Spacing = 6.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 819 psf OK Design Data
Soil Pressure @ Heel = 751 psf OK fb/FB + fa/Fa = 0.447
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 1,147 psf
ACI Factored @ Heel = 1,051 psf Strength Level lbs = 3,888.0
Moment....Actual
Footing Shear @ Toe = 19.8 psi OK
Service Level ft-# =
Footing Shear @ Heel = 8.2 psi OK
Strength Level ft-# = 11,664.0
Allowable = 75.0 psi
Moment.....Allowable = 26,082.9
Sliding Calcs
Lateral Sliding Force = 3,307.5 lbs
Service Level psi =
Strength Level psi = 42.5
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

185 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.3548 in2/ft
(4/3) * As : 0.473 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.3548 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.88 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 5.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 1,147 1,051 psf
Total Footing Width = 8.25 Mu' : Upward = 15,525 2,486 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,721 4,157 ft-#
Mu: Design = 11,804 1,671 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 19.82 8.24 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.21 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 7.17 19,425.3
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem = 300.0 5.67 1,700.0
Load @ Stem Above Soil = * Axial Live Load on Stem = 400.0 5.67 2,266.7
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.67 6,849.6
Total 3,307.5 O.T.M. 11,576.3
Earth @ Stem Transitions =
= = Footing Weight = 1,856.3 4.13 7,657.0
Resisting/Overturning Ratio = 3.08 Key Weight =
Vertical Loads used for Soil Pressure = 6,475.5 lbs Vert. Component =
Total = 6,075.5 lbs R.M. = 35,631.9
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

186 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.027 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

187 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

188 of 209
Avila Structural Consultants, Inc Title R.W. #5 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

189 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,134.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 6.50 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 5.50 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 392.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 253.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 1.65 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,308 lbs Rebar Size = # 6
...resultant ecc. = 19.25 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,852 psf OK Design Data
Soil Pressure @ Heel = 0 psf OK fb/FB + fa/Fa = 0.908
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,593 psf
ACI Factored @ Heel = 0 psf Strength Level lbs = 5,022.0
Moment....Actual
Footing Shear @ Toe = 33.6 psi OK
Service Level ft-# =
Footing Shear @ Heel = 19.1 psi OK
Strength Level ft-# = 18,468.0
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 4,441.5 lbs
Service Level psi =
Strength Level psi = 54.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

190 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.5617 in2/ft
(4/3) * As : 0.7489 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.5617 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 4.75 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,593 0 psf
Total Footing Width = 7.75 Mu' : Upward = 22,452 118 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,046 4,157 ft-#
Mu: Design = 19,406 4,040 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 33.56 19.09 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.92 in, #5@ 9.17 in, #6@ 13.02 in, #7@ 17.76 in, #8@ 23.38 in, #9@ 29.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.01 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 6.67 18,070.0
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,134.0 7.50 8,505.0 Axial Dead Load on Stem = 392.0 5.17 2,025.3
Load @ Stem Above Soil = * Axial Live Load on Stem = 253.0 5.17 1,307.2
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.17 6,245.2
Total 4,441.5 O.T.M. 20,081.3
Earth @ Stem Transitions =
= = Footing Weight = 1,743.8 3.88 6,757.0
Resisting/Overturning Ratio = 1.65 Key Weight =
Vertical Loads used for Soil Pressure = 6,308.0 lbs Vert. Component =
Total = 6,055.0 lbs R.M. = 33,097.6
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

191 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.064 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

192 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

193 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

194 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 392.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 253.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 2.86 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 6,308 lbs Rebar Size = # 6
...resultant ecc. = 3.07 in Rebar Spacing = 8.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 975 psf OK Design Data
Soil Pressure @ Heel = 653 psf OK fb/FB + fa/Fa = 0.574
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 1,365 psf
ACI Factored @ Heel = 914 psf Strength Level lbs = 3,888.0
Moment....Actual
Footing Shear @ Toe = 20.2 psi OK
Service Level ft-# =
Footing Shear @ Heel = 9.3 psi OK
Strength Level ft-# = 11,664.0
Allowable = 75.0 psi
Moment.....Allowable = 20,333.2
Sliding Calcs
Lateral Sliding Force = 3,307.5 lbs
Service Level psi =
Strength Level psi = 42.5
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

195 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.3548 in2/ft
(4/3) * As : 0.473 in2/ft Min Stem T&S Reinf Area 2.321 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.3548 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.66 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 4.75 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 1,365 914 psf
Total Footing Width = 7.75 Mu' : Upward = 14,362 2,243 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 3,046 4,157 ft-#
Mu: Design = 11,316 1,914 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 20.19 9.25 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 8.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.01 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,307.5 3.50 11,576.3 Soil Over Heel = 2,710.5 6.67 18,070.0
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem = 392.0 5.17 2,025.3
Load @ Stem Above Soil = * Axial Live Load on Stem = 253.0 5.17 1,307.2
= Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) = 1,208.8 5.17 6,245.2
Total 3,307.5 O.T.M. 11,576.3
Earth @ Stem Transitions =
= = Footing Weight = 1,743.8 3.88 6,757.0
Resisting/Overturning Ratio = 2.86 Key Weight =
Vertical Loads used for Soil Pressure = 6,308.0 lbs Vert. Component =
Total = 6,055.0 lbs R.M. = 33,097.6
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

196 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.034 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

197 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

198 of 209
Avila Structural Consultants, Inc Title R.W. #6 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

199 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Seismic Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.25 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 400.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 1,340.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 6.50 ft Footing Width = 0.00 ft
Surcharge Over Toe = 224.0 ...Height to Bottom = 5.50 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 0.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 2.00 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 7,507 lbs Rebar Size = # 6
...resultant ecc. = 19.46 in Rebar Spacing = 6.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 1,666 psf OK Design Data
Soil Pressure @ Heel = 0 psf OK fb/FB + fa/Fa = 0.794
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 2,333 psf
ACI Factored @ Heel = 0 psf Strength Level lbs = 5,447.0
Moment....Actual
Footing Shear @ Toe = 30.5 psi OK
Service Level ft-# =
Footing Shear @ Heel = 18.5 psi OK
Strength Level ft-# = 20,703.3
Allowable = 75.0 psi
Moment.....Allowable = 26,082.9
Sliding Calcs
Lateral Sliding Force = 4,806.9 lbs
Service Level psi =
Strength Level psi = 59.5
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

200 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Seismic Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.6297 in2/ft
(4/3) * As : 0.8396 in2/ft Min Stem T&S Reinf Area 2.381 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.6297 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.88 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 6.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 2,333 0 psf
Total Footing Width = 9.25 Mu' : Upward = 35,030 308 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 12,273 4,255 ft-#
Mu: Design = 22,757 3,947 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 30.48 18.54 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 6.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 5.05 in, #5@ 7.82 in, #6@ 11.10 in, #7@ 15.14 in, #8@ 19.94 in, #9@ 25.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.60 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,466.9 3.58 12,423.0 Soil Over Heel = 2,785.8 8.17 22,750.6
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = 1,340.0 7.50 10,050.0 Axial Dead Load on Stem =
Load @ Stem Above Soil = * Axial Live Load on Stem =
= Soil Over Toe =
Surcharge Over Toe = 1,400.0 3.13 4,375.0
Stem Weight(s) = 1,240.0 6.67 8,266.7
Total 4,806.9 O.T.M. 22,473.0
Earth @ Stem Transitions =
= = Footing Weight = 2,081.3 4.63 9,625.8
Resisting/Overturning Ratio = 2.00 Key Weight =
Vertical Loads used for Soil Pressure = 7,507.0 lbs Vert. Component =
Total = 7,507.0 lbs R.M. = 45,018.1
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

201 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Seismic Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.050 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

202 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Seismic Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

203 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Seismic Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 11 MAR 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

204 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Static Page : 1
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 27 FEB 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Criteria Soil Data


Retained Height = 9.25 ft Allow Soil Bearing = 2,000.0 psf
Equivalent Fluid Pressure Method
Wall height above soil = 0.67 ft
Active Heel Pressure = 60.0 psf/ft
Slope Behind Wall = 0.00 =
Height of Soil over Toe = 0.00 in Passive Pressure = 300.0 psf/ft
Water height over heel = 0.0 ft Soil Density, Heel = 139.00 pcf
Soil Density, Toe = 0.00 pcf
Footing||Soil Friction = 0.250
Soil height to ignore
for passive pressure = 12.00 in

Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load


Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 224.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding & Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Seismic (E)
Axial Load Applied to Stem (Service Level)
Footing Type Line Load
Base Above/Below Soil
Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf = 0.0 ft
at Back of Wall
Axial Live Load = 0.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in

Design Summary Stem Construction Bottom


Stem OK
Wall Stability Ratios Design Height Above Ftg ft = 0.00
Overturning = 3.62 OK Wall Material Above "Ht" = Concrete
Slab Resists All Sliding ! Design Method = LRFD
Thickness = 10.00
Total Bearing Load = 7,507 lbs Rebar Size = # 6
...resultant ecc. = 3.40 in Rebar Spacing = 6.00
Rebar Placed at = Edge
Soil Pressure @ Toe = 961 psf OK Design Data
Soil Pressure @ Heel = 663 psf OK fb/FB + fa/Fa = 0.485
Allowable = 2,000 psf
Total Force @ Section
Soil Pressure Less Than Allowable
Service Level lbs =
ACI Factored @ Toe = 1,345 psf
ACI Factored @ Heel = 928 psf Strength Level lbs = 4,107.0
Moment....Actual
Footing Shear @ Toe = 17.5 psi OK
Service Level ft-# =
Footing Shear @ Heel = 9.7 psi OK
Strength Level ft-# = 12,663.3
Allowable = 75.0 psi
Moment.....Allowable = 26,082.9
Sliding Calcs
Lateral Sliding Force = 3,466.9 lbs
Service Level psi =
Strength Level psi = 44.9
Shear.....Allowable psi = 75.0
Anet (Masonry) in2 =
Rebar Depth 'd' in = 7.63
Masonry Data
f'm psi =
Fs psi =
Solid Grouting =
Vertical component of active lateral soil pressure IS NOT Modular Ratio 'n' =
considered in the calculation of soil bearing pressures.
Wall Weight psf = 125.0
Load Factors Short Term Factor =
Building Code IBC 2015,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind, W 1.000 f'c psi = 2,500.0
Seismic, E 1.000 Fy psi = 60,000.0

205 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Static Page : 2
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 27 FEB 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Concrete Stem Rebar Area Details


Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment) : 0.3852 in2/ft
(4/3) * As : 0.5135 in2/ft Min Stem T&S Reinf Area 2.381 in2
200bd/fy : 200(12)(7.625)/60000 : 0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options :
============ One layer of : Two layers of :
Required Area : 0.3852 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.88 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions & Strengths Footing Design Results
Toe Width = 6.25 ft Toe Heel
Heel Width = 3.00 Factored Pressure = 1,345 928 psf
Total Footing Width = 9.25 Mu' : Upward = 24,431 2,254 ft-#
Footing Thickness = 18.00 in Mu' : Downward = 12,273 4,255 ft-#
Mu: Design = 12,157 2,002 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 17.46 9.74 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 6.00 in
f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 8.00 in
Min. As % = 0.0018 Other Acceptable Sizes & Spacings
Cover @ Top 2.00 @ Btm.=
= 3.00 in
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm
Key: No key defined

Min footing T&S reinf Area 3.60 in2


Min footing T&S reinf Area per foot 0.39 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.17 in #4@ 12.35 in
#5@ 9.57 in #5@ 19.14 in
#6@ 13.58 in #6@ 27.16 in

Summary of Overturning & Resisting Forces & Moments


.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 3,466.9 3.58 12,423.0 Soil Over Heel = 2,785.8 8.17 22,750.6
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem =
Load @ Stem Above Soil = * Axial Live Load on Stem =
= Soil Over Toe =
Surcharge Over Toe = 1,400.0 3.13 4,375.0
Stem Weight(s) = 1,240.0 6.67 8,266.7
Total 3,466.9 O.T.M. 12,423.0
Earth @ Stem Transitions =
= = Footing Weight = 2,081.3 4.63 9,625.8
Resisting/Overturning Ratio = 3.62 Key Weight =
Vertical Loads used for Soil Pressure = 7,507.0 lbs Vert. Component =
Total = 7,507.0 lbs R.M. = 45,018.1
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.

Vertical component of active lateral soil pressure IS NOT considered in


the calculation of Overturning Resistance.

206 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Static Page : 3
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 27 FEB 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)

Soil Spring Reaction Modulus 250.0 pci


Horizontal Defl @ Top of Wall (approximate only) 0.029 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.

207 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Static Page : 4
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 27 FEB 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

208 of 209
Avila Structural Consultants, Inc Title R.W. #7 : - Static Page : 5
5315 Magnolia Blvd. #429 Job # : Dsgnr: J.I.S. Date: 27 FEB 2018
Sherman Oaks, CA 91302 Description....
Cell 818-489-4076
www.AvilaEngineers.com
This Wall in File: C:\Users\D5\Desktop\Santa Monica RW.RPX
RetainPro (c) 1987-2017, Build 11.17.04.04
License : KW-06057443 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13
License To : GED

209 of 209

Das könnte Ihnen auch gefallen