AD00.19-N-9014GA Fault code list for heater control (HZR) control unit 11.1.

08
MODEL 930, 932, 933, 934

Fault code Fault code description


0000 Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/7) to component B119 has Short circuit to
ground.
or
Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/7) to component B119 has Short circuit to
positive or Open circuit.
0001 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/12) to component A13m1 has Short circuit
to ground.
0002 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/12) to component A13m1 has Short circuit
to positive.
0101 Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/1) to control unit A61 has Short circuit to
ground.
0103 Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/1) to control unit A61 has Short circuit to
positive or Open circuit.
0201 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/21) to component A13b3 has Short circuit
to ground.
0203 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/21) to component A13b3 has Short circuit
to positive or Open circuit.
0301 Line from control and operating unit 'Heater control HZR' (pin X1 9/1) to component B46 has Short circuit to ground.
or
Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/4) to component B46 has Short circuit to
ground.
or
Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/4) to control unit Stationary air conditioner
has Short circuit to ground.
0303 Line from control and operating unit 'Heater control HZR' (pin X1 9/1) to component B46 has Short circuit to positive or
Open circuit.
or
Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/4) to component B46 has Short circuit to
positive or Open circuit.
or
Line from control and operating unit 'Automatic air conditioning KLA' (pin X1 9/4) to control unit Stationary air conditioner
has Short circuit to positive or Open circuit.
0401 Line from control and operating unit 'Heater control HZR' (pin X2 21/6) to component A13m3 has Short circuit to ground.
0405 Line from control and operating unit 'Heater control HZR' (pin X2 21/6) to component A13m3 has Open circuit or Short
circuit to positive.
0501 Line from control and operating unit 'Heater control HZR' (pin X2 21/18) to component A13m4 has Short circuit to ground.
0505 Line from control and operating unit 'Heater control HZR' (pin X2 21/18) to component A13m4 has Open circuit or Short
circuit to positive.
0602 Line from control and operating unit 'Heater control HZR' (pin X2 21/12) to component A13m3 has Short circuit to positive.
0605 Line from control and operating unit 'Heater control HZR' (pin X2 21/12) to component A13m3 has Open circuit or Short
circuit to ground.
0702 Line from control and operating unit 'Heater control HZR' (pin X2 21/17) to component A13m3 has Short circuit to positive.
0705 Line from control and operating unit 'Heater control HZR' (pin X2 21/17) to component A13m3 has Open circuit or Short
circuit to ground.
0802 Line from control and operating unit 'Heater control HZR' (pin X2 21/15) to component A13m3 has Short circuit to positive.
0805 Line from control and operating unit 'Heater control HZR' (pin X2 21/15) to component A13m3 has Open circuit or Short
circuit to ground.
0902 Line from control and operating unit 'Heater control HZR' (pin X2 21/19) to component A13m3 has Short circuit to positive.
0905 Line from control and operating unit 'Heater control HZR' (pin X2 21/19) to component A13m3 has Open circuit or Short
circuit to ground.
0A01 Line from control and operating unit 'Heater control HZR' (pin X2 21/5) to component A13m2 has Short circuit to ground.
0A02 Line from control and operating unit 'Heater control HZR' (pin X2 21/5) to component A13m2 has Short circuit to positive.
0A05 Line from control and operating unit 'Heater control HZR' (pin X2 21/5) to component A13m2 has Open circuit.
0B01 Line from control and operating unit 'Heater control HZR' (pin X2 21/3) to component A13m2 has Short circuit to ground.
0B02 Line from control and operating unit 'Heater control HZR' (pin X2 21/3) to component A13m2 has Short circuit to positive.
0B05 Line from control and operating unit 'Heater control HZR' (pin X2 21/3) to component A13m2 has Open circuit.
0C01 Line from control and operating unit 'Heater control HZR' (pin X2 21/1) to component A13b4 has Short circuit to ground.
0C03 Line from control and operating unit 'Heater control HZR' (pin X2 21/1) to component A13b4 has Short circuit to positive or
Open circuit.
0D01 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/5) to component A13b1 has Short circuit to
ground.
0D03 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/5) to component A13b1 has Short circuit to
positive or Open circuit.
0F02 Line from control and operating unit 'Heater control HZR' (pin X2 21/9) to component A13m4 has Short circuit to positive.
0F05 Line from control and operating unit 'Heater control HZR' (pin X2 21/9) to component A13m4 has Open circuit or Short
circuit to ground.
1002 Line from control and operating unit 'Heater control HZR' (pin X2 21/20) to component A13m4 has Short circuit to positive.
1005 Line from control and operating unit 'Heater control HZR' (pin X2 21/20) to component A13m4 has Open circuit or Short
circuit to ground.

© Daimler AG, 10/25/11, G/09/11, ad00.19-n-9014ga, Fault code list for heater control (HZR) control unit Page 1 of 2
MODEL 930, 932, 933, 934
1102 Line from control and operating unit 'Heater control HZR' (pin X2 21/14) to component A13m4 has Short circuit to positive.
1105 Line from control and operating unit 'Heater control HZR' (pin X2 21/14) to component A13m4 has Open circuit or Short
circuit to ground.
1202 Line from control and operating unit 'Heater control HZR' (pin X2 21/16) to component A13m4 has Short circuit to positive.
1205 Line from control and operating unit 'Heater control HZR' (pin X2 21/16) to component A13m4 has Open circuit or Short
circuit to ground.
1301 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/15) to component A13b3 has Short circuit
to ground.
1303 Line from control and operating unit 'Automatic air conditioning KLA' (pin X2 21/15) to component A13b3 has Short circuit
to positive or Open circuit.
1305 Sensor fault(A13b3)