Sie sind auf Seite 1von 3

THUNDER ENERGY SERVER FEATURES:

• High reliability: adopt high-speed DSP control system, combine advanced SPWM technology and
high-speed power MOS
• Operating mode selectable: energy storage priority or power supply priority
• No PID attenuation damage for solar panels to ensure their service life
• Flexible battery management system: auto switch three-stage charging mode shortens recharge
time; wide charging current is selectable according to configured battery; flexible DOD (depth of
discharge) is settable to meet more applications
• AC input with effective online synchronous stabilizing technology
• Broad MPPT input voltage range
• No-load auto shut down function(optional)
• Settable frequency(50Hz/60Hz)
• Mobile APP monitoring
• Auto Power-On/Off function; real-time monitoring, test and intelligent startup/shutdown by
RS232 or USB interface communicating with PC; remote monitoring by optional SNMP networks
SPECIFICATIONS
MODEL 500W 1000W 2000W 2500W 3000W
PV INPUT
Max input voltage (Voc) 60Vdc 100Vdc 150Vdc
Optimum operating 16~48Vdc 33~80Vdc 65~120Vdc
voltage (Vmp)
Max charging current 50A 50A 50A 65A 65A
Recommended PV 700W 1400W 2800W 3500W 3500W
configuration
AC INPUT
AC input range (bypass 0~132Vac/0~264Vac (high-end limit)
mode)
Rated input voltage 100Vac/110Vac/115Vac/120Vac or 200Vac/220Vac/230Vac/240Vac±25%
(2500W is only for 110Vac;3000W is only for 220Vac)
Rated input frequency 50Hz/60Hz±5%/10%/15%(settable)
Maximum charging 20A 30A
current
INVERTER OUTPUT
Output Voltage 100Vac/110Vac/115Vac/120Vac±2%or
200Vac/220Vac/230Vac/240Vac±2%(settable)
(2500W is only for 110Vac;3000W is only for 220Vac)
Rated output power 500W 1000W 2000W 2500W 3000W
Power factor 1
Rated output frequency 50Hz/60Hz±1% (inverter mode)
Waveform Sinusoidal
Max.efficiency(resistive ≥78% ≥82% ≥85% ≥85% ≥85%
load)
Sleep mode Settable (<3% load) access in ≤2min
Output voltage harmonic ≤3% (linear load)
BATTERIES
Battery Voltage 12Vdc 24Vdc 48Vdc
Battery type VRLA battery(default), GEL/Sirius Capacitor Module
Charging current 5~50A(settable) 5~50A(settable) 5~65A(settable)
DOD Settable 10.5~13.2Vdc 21~26.4Vdc 42~52.8Vdc
Default 12Vdc 24Vdc 48Vdc
EOD Settable 9.6~12Vdc 19.2~24Vdc 38.4~48Vdc
Default 10.5Vdc(default) 21Vdc 42Vdc
Equalizing Settable 13.8~15Vdc 27.6~30Vdc 55.2~60Vdc
charge
voltage Default 14.1Vdc 28.2Vdc 56.4Vdc
Floating Settable 13.2~13.8Vdc 26.4~27.6Vdc 52.8~55.2Vdc
charge Default 13.6Vdc 27.2Vdc 54.5Vdc
voltage
Restoration point of over 15.5Vdc 31Vdc 62 Vdc
voltage

OTHERS
Transfer Time 3~6ms(typical); ≤10ms(max.)
Overload (linear load) 110% for 2min,125% for 1min,150% for10s,180% for 1s
ECO mode (optional) Load<3%(settable), Yes/No settable
No-load shut Load<3%~50%, Yes/No settable
down(optional)
Load adaptation Inductive load: ≤30%; capacitive load: ≤50%; resistive load: ≤100%
Protections Output overload-short-circuit-over discharge-overcharge-battery reverse polarity-
PV reverse polarity
Lightning protection Class III
Communications RS232/USB/RS485; SNMP/Wi-Fi/GPRS (optional)
Standards IEC62040, IEC/EN61000
IP rating 1P21
Display LCD&LED
Operating temperature 0◦C~40◦C
Relative humidity ≤93%
Noise <50dB
Dimensions (WXDXH)(mm) 365.5X442X210
Packaged Dimensions 455X520X283
(WXDXH)(mm)
Net weight(kg) 16.6 19.5 30.4 32.8 38.5
Gross weight(kg) 18.1 21 31.9 34.3 40
• All specifications subject to change without notice

Das könnte Ihnen auch gefallen