Beruflich Dokumente
Kultur Dokumente
2/3
Heat pumps utilise renewable energy from the ground, sun, groundwater or air.
They lower consumption of fossil fuels, conserve valuable resources and reduce
CO2 emissions that damage the environment.
Viessmann heat pumps offer their users an additional benefit – many of them
feature active and natural cooling functions. Alongside their classic application as
heat generators on cold days, they can also create a pleasant interior in summer by
bringing refreshing cool air into the house.
Viessmann's extensive product range offers the right heat pump to suit every
demand. Even at the design stage, structural and geological conditions, as well
as personal and individual preferences concerning the heat demand can be taken
into account. Running a heat pump with power generated on site by a photovoltaic
system is particularly environmentally responsible and very affordable.
Viessmann heat pumps can be used in new build and modernisation projects,
operated together with solar thermal systems and even combined with an existing
oil or gas heating system to form a multi mode system. This allows every building
and property owner to put their plans into action in the most efficient way possible.
Contents
4/5
Heat pumps from Viessmann offer tailor-made solutions for central heating and cooling, as
well as convenient hot water supply, for both new build and modernisation projects.
The company
from page 74
The power of innovation: a family business for three generations,
Viessmann offers state of the art technology and takes its
responsibilities seriously.
How it works
1 2 3 1 2 3
Energy from the ground, air and sun Energy from groundwater
(Vitofriocal ice store system)
1 2 3
1
1 2 3 1 2
Heat pumps work like a refrigerator, just in Air – unlimited availability; lowest
reverse. While a refrigerator directs heat to investment outlay
the outside, heat pumps take energy from the Ground – via geothermal collector,
air or the ground and transfer it into the living geothermal probe or ice store; very
space via the heating system. The transfer efficient
medium carrying the heat drawn from the Water – extremely efficient; observe water
environment is compressed in order to reach quality
the flow temperatures necessary for different Waste heat – subject to availability, amount
heating systems. and temperature level
Getting hotter towards the centre: at an initial temperature of between 5 and 18 °C, a flow temperature of up
to 72 °C is reached.
Connectivity ViCare app
Vitoconnect
The ViCare app offers new possibilities for Yellow lets you know about a pending service
controlling heating systems via the internet. and red automatically offers to contact the
The design of the ViCare graphic interface contractor.
has been kept simple, enabling completely
intuitive heating system operation. This requires consent from the system user,
which can be granted within the app with
Save energy automatically just two taps. The connection to the trade
The system is designed to control one partner's software is then established and
heating circuit. You can set the required room they can view the system data, in order to Vitoconnect with sockets for the
plug-in power supply unit (left) and
temperature via the touchscreen, and switch provide their customer with quick and
data connection
between standard and party mode efficient support.
("I'm home longer") with a single tap.
Vitoconnect internet interface
When leaving the house ("I'm away"), it takes Vitoconnect is the interface between the 5 year guarantee*
just one command to reduce the heating boiler and ViCare. It is not only compatible with system web connection/
system to a lower temperature and therefore with new Viessmann heating systems, but is connectivity
save energy. Anyone wanting to program also available for many existing appliances.
different switching times for each day will It is connected directly via a cable. A plug-in * For conditions see
www.viessmann.de/garantie
appreciate the assistant function. power supply unit is included in the standard
delivery. A small accessory, measuring only
A separate button on the start screen shows 10 x 10 cm, is available for wall mounting.
the current outside temperature and, with just
one tap, the temperature history over the last Connect the module to the internet and
few days. register via plug & play. Simply scan the
supplied QR code using a smartphone.
System status at a glance Installation and commissioning is then
The user can see at a glance whether their usually completed in just a few minutes.
heating system is working as it should.
1)
Accessories required
Air source heat pumps 10/11
2.3 to 50.0 kW
Q Q Q Q 36/38
Vitocal 200-S/222-S
2.3 to 12.0 kW
Q Q Q Q 42
Vitocal 350-A
10.6 to 18.5 kW
Q Q Q Q Q 44
Vitocal 300-A
5.8 to 13.4 kW
Q Q Q Q 46
Vitocal 200-A
2.6 to 12.4 kW
Q Q Q Q Q 48/50
Vitocal 200-A/222-A
2.3 to 12.0 kW
Q Q Q Q Q 52
Vitocal 262-A
300 litres
Q Q Q Q 54
Vitocal 300-A
11.3 to 50.0 kW (two-stage)
Brine/water
heat pumps
12/13
Compact brine/water heat pumps with heating outputs from 5.7 to 10.4 kW
Low operating costs thanks to high coefficient of performance (COP) to EN 14511
of up to 5.0 (B0/W35)
Easy to use Vitotronic control unit with plain text display
Ready to connect, ex works
Prepared for the use of power generated on site, for example by photovoltaic systems
Web-enabled via free ViCare app and Vitoconnect (optional)
Brine/water VITOCAL 333-G NC / VITOCAL 333-G
heat pumps VITOCAL 343-G
5.7 to 10.4 kW
7
4 Vitocal 333-G
Compact brine/water heat pumps with heating outputs from 5.7 to 10.4 kW
High DHW convenience through integral DHW cylinder with 220 litre capacity
(Vitocal 343-G) and 170 litre capacity (Vitocal 333-G NC/333-G)
Very quiet thanks to an innovative sound attenuation concept resulting in a sound power level
of 38 dB(A) at B0/W35
Flow temperature: up to 65 °C for high DHW convenience
Power saving high efficiency pumps
Control of a Vitovent 300-F mechanical ventilation unit
Integral natural cooling (NC) function for the Vitocal 333-G NC
Instantaneous heating water heater as standard
8 Vitocal 242-G
6
1 Heating lance
7 2 Enamelled DHW cylinder
3 Vitotronic 200 heat pump control unit
4 Integral solar indirect coil
9 5 Modulating cylinder loading pump
6 Primary circulation pump
7 Secondary circulation pump
8 Diverter valve, central heating/DHW
9 Integral instantaneous heating water heater
16/17
Compact brine/water heat pumps with heating outputs from 6.1 to 10.0 kW
High DHW convenience through integral DHW cylinder with 220 litre capacity (Vitocal 242-G) and
170 litre capacity (Vitocal 222-G)
Very quiet thanks to the sound-optimised appliance design with a sound power level of 43 dB(A) at
B0/W35
Flow temperature: up to 60 °C
Natural cooling (NC) function with optional NC-Box
Instantaneous heating water heater as standard
VITOCAL 300-G
VITOCAL 200-G
Flexible configuration of Viessmann heat pumps: either brine/water heat pump, or
water/water heat pump with conversion kit, depending on the primary energy source
The floorstanding Vitocal 300-G and Vitocal As an alternative, depending on the location
200-G brine/water heat pumps recover heat of the house, it may also be possible to
from high yielding heat sources. For this utilise the thermal energy contained in the
purpose, a geothermal probe, geothermal groundwater. In addition, the Vitocal 300-G
collector or Vitofriocal ice store system is can also be configured for straightforward
installed on the property. In all these cases, operation as a water/water heat pump. They
these appliances cover the entire energy are equally well suited to new build and
demand, even on colder days. modernisation, in both detached houses and
apartment buildings.
Year-round mono mode operation for DHW and central heating possible
Vitocal 300-G: low operating costs with the highest level of efficiency at every operating point due
to the innovative refrigerant cycle diagnostic (RCD) system with electronic expansion valve (EEV)
Prepared for the use of power generated on site, for example by photovoltaic systems
Web-enabled via free ViCare app and Vitoconnect (optional)
Control of Viessmann ventilation units possible
Easier handling through small and light modules
Brine/water VITOCAL 300-G
heat pumps 5.7 to 17.2 kW (single stage)
11.4 to 34.4 kW (two-stage)
4 Vitocal 300-G
2
3
4 Vitocal 200-G
Vitotronic 200 control unit with optional Prepared for photovoltaic power
app control The Vitocal 200-G heat pump is already
The Vitotronic 200 control unit, with plain text prepared for the utilisation of more affordable
and graphic display, is simple and intuitive power generated on site by a photovoltaic
to use. Settings can quickly be changed via system. An intelligent controller increases
the menu. Control via the internet through on-site consumption of power generated by
the Vitotrol app on a mobile device is also an the PV system.
option.
VITOCAL 350-G
VITOCAL 300-G
Powerful heat pumps with high flow temperatures meet the requirements for
high DHW convenience in large detached houses and apartment buildings.
With its two high temperature heat pumps, the Perfect for high heating output
Vitocal 350-G and Vitocal 300-G, Viessmann The Vitocal 350-G/300-G is an economical
also meets the demand for higher heating solution for higher heat demands. It allows
outputs. Four sizes are available up to 84.6 kW. the heating flow and return lines of several
heat pumps to be linked in a cascade.
EVI for high flow temperatures
The Vitocal 350-G achieves high flow A heat pump cascade consists of one lead
temperatures of up to 70 °C. This results from heat pump and up to four lag heat pumps.
the use of an EVI (enhanced vapour injection) Both the lead heat pump and the lag heat
refrigerant circuit, where an intermediate pumps can have two stages. This not only
vapour injection cools the refrigerant so that delivers the higher heating output required,
it can be more densely compressed than is but also increases the operational reliability of Energy efficiency label
Vitocal 300-G, BW 301.A21
otherwise possible. the entire system.
The Vitocal 350-G also delivers sufficiently
high temperatures to make it suitable for The modular design, with separate
modernising apartment buildings with radiator compressor circuits, also ensures particularly
heating systems. high levels of efficiency in partial load
operation, and enables simultaneous DHW
RCD system for highest level of efficiency and central heating.
RCD stands for refrigerant cycle diagnostic
system. This provides constant monitoring of
the refrigerant circuit in Vitocal high EHPA Quality Label
Vitocal 350-G
(master)
The powerful Vitocal 350-G brine/water heat Furthermore, the Vitotronic 200 is capable
pump is one of the quietest heat generators of of communicating, and via the Vitocom 300
its kind, thanks to its low-vibration design. module, allows the heat pump system to be
set up, monitored and optimised over the
Where heat demand is even higher, the internet with the Vitotrol app on a smartphone
Vitocal 350-G can be operated in two-stage or tablet.
mode with an additional heat pump of the
same type, or with a Vitocal 300-G in a Operation with solar power generated
master/slave system, and can then provide on site
an output of up to 84.6 kW. As early as at the The Vitocal 350-G heat pump is already
design stage, this system configuration allows prepared for the utilisation of more affordable
for optimum matching of the heat pumps to power generated on site by a PV system.
the heat demand. An intelligent control unit ensures maximum
consumption of self-generated power while
Master/slave system for DHW and lowering energy costs.
central heating
In a master/slave system, the Vitocal 350-G
(master) delivers high flow temperatures for
DHW heating, while the Vitocal 300-G
(slave, without its own control unit) covers
the required heat load.
Two-stage Vitocal 350-G
(master on the right/slave on the left)
as a brine/water or water/water heat
pump
3
4
Vitocal 300-G
5
1 Vitotronic 200 heat pump control unit
2 Condenser
3 Large area evaporator for an efficient
exchange of heat
4 High efficiency pump
5 Hermetically sealed Compliant scroll
compressor
28/29
Cascades up to 589 kW
It can deliver a heating output from 42.4 to
85.6 kW (brine/water) with ground as the
primary heat source, or 56.2 to 117.8 kW
(water/water) when using groundwater. If this
is not enough, the integral cascade function
enables output to be raised to up to 589 kW
(water/water) with several Vitocal 300-G
units.
A
1
5
B
3
The use of an ice store as an energy source is Package solutions for easy installation
an innovative solution. The ice store consists Viessmann is the only heat pump
of a tank with built-in heat exchangers which manufacturer to exclusively offer the
is buried in the garden and filled with ordinary innovative Vitofriocal ice store system. For
tap water. Special solar air absorbers installed heat pumps with a rated heating output from
on the roof of the building draw heat from the 6.0 to 17.2 kW, various standard system
ambient air, as well as from insolation, and packages are currently available which greatly
supply it to the tank. The ice store also draws facilitate the engineering and ordering of
energy directly from the ground. components. These packages comprise an
ice store with built-in heat exchangers, solar
Using crystallisation energy for heating air absorbers with a roof mounting system
The heat pump extracts the energy required and the heat transfer medium for the primary
for DHW and central heating from the water circuit.
in the tank as required. If the temperature in
the tank falls to freezing point, more energy is Larger properties with a greater heat demand
drawn from the freezing effect of the water – require a customised ice store and solar air
hence the term "ice store". absorbers. Viessmann offers the relevant
support for this.
During the transition from water to ice, the
amount of crystallisation energy released No official permits required
is equivalent to that required for the inverse A further benefit of the Vitofriocal ice store
process of thawing. With an ice store that can system: it does not require the costly
hold ten cubic metres – the standard size for drilling that is necessary for accessing
a detached house – this corresponds to the geothermal energy from deep in the ground,
energy content of approx. 120 litres of fuel oil. or the extensive groundwork involved when
embedding geothermal collectors over a
The key difference is that the fuel oil is entirely large area. Nor does it require any official
consumed to generate heat, whilst the water permits, as the ice store has no impact on
content of the ice store can be used time and groundwater.
time again to generate heat using energy from
the sun and air.
Combined utilisation of ambient air, the ground and insolation as energy sources
No drilling – no environmental risk, no permits required
Low operating costs thanks to the high COP of the heat pumps of up to 5.0 (B0/W35) to EN 14511
Particularly high efficiency thanks to intelligent heat source management and heat pump with RCD
(refrigerant cycle diagnostic) system with electronic expansion valve (EEV)
Easy to use Vitotronic control unit integrated in the heat pump
Natural cooling NC-Box
Active cooling AC-Box
NC-Box
Optional equipment for Viessmann
heat pumps to provide passive cooling
AC-Box
Optional equipment for Viessmann
heat pumps to provide active cooling
32/33
Besides generating high levels of heating comfort and reliable DHW heating,
heat pumps can also provide cooling for rooms in hot weather.
In addition to its primary function as a heating Active cooling with AC-Box – efficient
appliance, heat pumps can also provide heating and cooling
cooling using two different methods: The AC-Box combines active and natural
cooling in heat pump systems, thus making
With passive cooling (natural cooling), the them even more versatile and convenient. The
brine medium or the groundwater absorbs system changes over automatically according to
the energy from the heating circuit via a the required room temperature. If only a low
heat exchanger and transfers it outdoors. cooling capacity is required, natural cooling
The natural ambient temperature is also is sufficient. However, when that is no longer
used for cooling. Apart from the control enough, active cooling is added.
unit and circulation pump, the heat pump
remains switched off. This makes natural Keeping cool when it's hot outside
cooling a particularly energy efficient and The compressor circuit "kicks in" for active
affordable way to cool the interior of a cooling. Using the AC-Box, the internal control
building. unit reverses the output and input functions
and now actively transfers heat from the
With active cooling, the function of the building to the geothermal probe. Cold water
heat pump is simply reversed. For this, then flows through the heating circuit itself –
the refrigerant cycle is reversed internally; cooled down to 7 °C if necessary.
alternatively the primary and secondary
connections are changed over. As with Utilising the energy removed
a fridge, the heat pump then actively Incidentally, direct use can also be made of
generates a cooling capacity. the heat removed from the interior in this
way, for example for DHW heating or to heat
Natural cooling with NC-Box – energy a swimming pool. This means cooling and
efficient and affordable heating functions can be combined extremely
All the components are prefitted in the effectively.
Viessmann NC-Box. This makes the thermally
insulated box not only compact, but also
particularly simple and quick to install.
VITOCAL 200-S
VITOCAL 222-S
Split heat pumps are characterised by their separation into an indoor unit and an
outdoor unit.
As with other heating systems, the actual Convenient Vitotronic control unit
heat generator is installed inside the building. The Vitotronic 200 control unit, with user
With a maximum width of 600 mm (just prompts, is structured logically and is easy
450 mm in the case of the Vitocal 200-S), to follow. The large backlit display offers
the indoor units can be sited in a basement good contrast, making it easy to read. A help
or even close to the living space in a utility function informs users of the next steps
room, or wall mounted (Vitocal 200-S). to perform. The graphic user interface also The Vitocal 200-S/222-S are
certified in accordance with the
displays heating and cooling curves.
EHPA Quality Label for heat pumps
A high proportion of prefitted components
and the Heat Pump KEYMARK.
makes these compact heating centres easy Efficient and economical
for heating contractors to install, which Split heat pumps operate with astonishing
reduces installation costs. efficiency in partial load operation. The
inverter technology accurately matches
the compressor output to the current heat
demand through modulation, resulting in
high efficiency at every operating point.
The inverter compressor enables optimum output matching to the heat and cooling demands
Convenient reversible design that enables heating and cooling
High efficiency in partial load operation through output-controlled compressor
Low sound power level of the outdoor unit in partial load operation through variable speed fan
and compressor
No frost protection needed for the connection lines as there is no risk of the refrigerant-filled
lines freezing
Easy to use Vitotronic 200 control unit with plain text and graphic display
Control of Viessmann ventilation units possible
Easy and affordable installation without costly wall outlets
Prepared for the use of power generated on site, for example by photovoltaic systems
Web-enabled via free ViCare app and Vitoconnect (optional)
Air source VITOCAL 200-S
heat pumps 2.3 to 12.0 kW
1
2
7 10
3
4
11
9
5
8
2
3
5
4
6
Indoor units
VITOCAL 350-A
VITOCAL 300-A/200-A/222-A
Air source heat pumps utilise free energy from the ambient air for heating.
This makes them suitable for both new build and modernisation.
The Vitocal 350-A air source heat pump is Space saving outdoor installation
particularly suitable for modernisation; the Depending on the version chosen, the heat
Vitocal 300-A for modernisation and new pumps can be installed indoors or outdoors.
build; and the Vitocal 200-A/222-A for new Outdoor installation is a particularly space
build. efficient solution. Only the control unit and
hydraulic components are mounted on the
Compared to a brine/water system, an wall inside the house.
investment in an air source heat pump is The Vitocal 350-A, Vitocal 300-A
and Vitocal 200-A/222-A are certified
lower, as the costs for installing a geothermal Viessmann offers everything
in accordance with the EHPA Quality
collector or drilling holes for geothermal from a single source Label for heat pumps.
probes are not incurred. When it comes to transporting heat into
your home, you can rely on Viessmann's
system competence. All pipework required
for connecting the heat pump, as well as the
entire range of accessories, are provided from
a single source, and are perfectly matched to
one another.
Low operating noise through generously sized air ducts, sound-optimised appliance design and
night mode with reduced fan speed
Easy to operate Vitotronic control unit with plain text and graphic display
Control of Viessmann ventilation units possible
Installation indoors or outdoors with matching accessories
Efficient defrosting through circuit reversal
Prepared for the use of power generated on site, for example by photovoltaic systems
Web-enabled via free ViCare app and Vitoconnect (optional)
Air source VITOCAL 350-A
heat pumps 10.6 to 18.5 kW
2 4 2
Vitocal 350-A
5
1 Intake side
2 Discharge side
6 3 Evaporator
7 4 Radial fan
5 Electronic expansion valve
6 Heat exchanger for enhanced
vapour injection
7 Hermetically sealed Compliant
scroll compressor with enhanced
vapour injection (EVI)
42/43
High DHW convenience the Vitocal 350-A all year round. It delivers a
Subject to system version, a higher flow high COP of up to 3.6 (to EN 14511 at A2/
temperature enables a water temperature W35). This results in high annual coefficients
of up to 55 °C inside the DHW cylinder. of performance and very low operating costs.
This allows the Vitocal 350-A to deliver a
particularly high level of DHW convenience. Space saving installation
The Vitocal 350-A achieves its high flow The Vitocal 350-A can be installed either
temperature of 65 °C even at outside indoors or outdoors. The three-stage radial
temperatures as low as – 10 °C. fan in the heat pump, as well as the flow-
optimised air routing and the sound insulated
RCD system for particularly high efficiency casing together make the Vitocal 350-A
The electronic expansion valve and RCD extremely quiet. During night operation the
(refrigerant cycle diagnostic) system also multi stage fan control unit reduces the fan
ensure an extremely high level of efficiency for speed, and thus noise emissions, even further.
Air source heat pump, mono mode with heating output from 10.6 to 18.5 kW for DHW and
central heating
Flow temperature: up to 65 °C
Low operating costs thanks to high coefficient of performance (COP) to EN 14511 of up to 3.6
(A2/W35)
Matched product accessories for quick and easy hydraulic connection
Efficient defrosting through circuit reversal
With integral energy statement
Vitocal 300-A
5 6
1 Coated evaporator
2 Sheath current air routing
3 Variable speed EC fan
4 Flow optimisation
5 Variable speed scroll compressor
7 6 Condenser
7 Hydraulic connections
44/45
The Vitocal 300-A air source heat pump stands Wireless or app operation
out not only on account of its contemporary The Vitocal 300-A is equipped with the
design. With a maximum flow temperature of Vitotronic 200 control unit (type WO1C). It is
65 °C for central heating and convenient DHW preset for wireless remote operation and
heating, this appliance is particularly suitable for allows convenient control from the living
modernising detached and two-family houses. space. In conjunction with the ViCare app and
Vitoconnect, the system can also be
Flexible and quiet controlled from anywhere via a smartphone or
The Vitocal 300-A air source heat pump is tablet.
installed outside the building and utilises
free ambient air. Thanks to its variable speed Prepared for operation with photovoltaic
DC fan, modulating compressor and sound- power and Smart Grid
optimised design with sheath current air Connecting to a photovoltaic system enables
routing, the heat pump is exceptionally quiet, further savings on operating costs. The power
with a sound power level below 54 dB(A). generated on site can, for example, be used
The fan speed can also be reduced at night. to run the Vitocal 300-A. The Vitocal 300-A Energy efficiency label
Vitocal 300-A, AWO-AC 301.B14
is also prepared for Smart Grid applications
High COP for reliable heat supply (intelligent integration of consumers in power
The variable speed scroll compressor with grids).
brushless permanent magnet motor and
vapour injection, as well as the electronic
bi-flow expansion valve, contribute to the
high COP to EN 14511 of up to 5.0 (A7/W35).
Reversible air source heat pump for heating and cooling, for outdoor installation
Rated heating output: 5.8 and 13.4 kW at A2/W35
Low operating costs thanks to high coefficient of performance (COP) to EN 14511: up to 5.0 at
A7/W35 and 4.0 at A2/W35
Flow temperature: up to 65 °C at –5 °C outside temperature
Low operating noise thanks to sound-optimised DC fan, reduced fan speed in night mode and
sound-optimised appliance design
Optional control and monitoring with wireless remote control units or ViCare app
Prepared for Smart Grid and optimised utilisation of power generated on site
2
3
Vitocal 200-A
9
1 Evaporator
4 2 Vitotronic 200 control unit
10
(type WO1C)
5
3 Variable speed radial DC fan
4 Condenser
7
8 5 Filter dryer
6 6 Instantaneous heating water heater
7 High efficiency pump
8 Compressor with output-dependent control
9 Electronic expansion valve
10 3-way diverter valve
46/47
Reversible air source heat pump for heating and cooling, for indoor installation
Rated heating output: 2.6 and 12.4 kW at A2/W35
Low operating costs thanks to high coefficient of performance (COP) to EN 14511: 3.8 (A2/W35)
Flow temperature: up to 60 °C at 5 °C air intake temperature
Easy to use, integral Vitotronic 200 (type WO1C) control unit;
can be controlled using the Vitotrol app
Control of a Vitovent 300-F mechanical ventilation unit
Optimised utilisation of power generated on site by photovoltaic systems
6 11
1
10
2
8
5 9
3 7
3 Secondary pump (high efficiency circulation pump) 9 Variable speed scroll compressor
Air source heat pumps with a monoblock design are characterised by separation into an
indoor unit and an outdoor unit, with water-carrying connection lines.
3
5
6
1 Instantaneous heating water heater
2 3-way diverter valve
for central heating/DHW heating
3 Flow switch
4 Secondary pump
(high efficiency circulation pump)
5 Vitotronic 200 control unit
6 Enamelled DHW cylinder
(220 litre capacity)
50/51
1 2 1 2
3 3
6 6
5 Vitocal 262-A
5
1 Highly efficient compressor
7 7 2 Large area evaporator for an
efficient heat exchange
3 Control unit
4 Indirect coil (hybrid version)
5 Magnesium anode
6 Dry immersion heater
(accessory for the hybrid version)
7 300 litre DHW cylinder with
Ceraprotect enamel coating
VITOCAL 262-A
DHW heat pump for efficient DHW heating
The Vitocal 262-A DHW heat pump heats Available for recirculation air or outdoor air
domestic hot water affordably and efficiently, The recirculation air version, Vitocal 262-A,
independently of any other central heating utilises air straight from the room where it is
system, by utilising indoor or outdoor air. The installed. Part of the heat from the air that is
heat pump is equally suitable for detached drawn in is extracted and raised to a useful
houses or small commercial enterprises. temperature level (up to 65 °C for improved
Typical applications include bakeries or server DHW hygiene). This removes moisture
rooms, where above average amounts of heat from the rooms, thus protecting the fabric Vitocrossal 300 gas condensing
boiler (left) with Vitocal 262-A
are produced. of the building and improving the indoor
DHW heat pump (type T2H)
environment.
Hybrid version for combination with
existing boilers In outdoor air operation, the appliance
The heat pump is available without an operates in a temperature range of – 8 to
indirect coil (type T2E) for mono mode + 40 °C and can therefore also be operated in
operation. Alternatively, the hybrid version more extreme climatic zones.
with an integral indirect coil (type T2H)
can be selected. This is recommended for Dry immersion heater
retrofitting and upgrading existing systems. The electric version (type T2E) is equipped at
The intelligent control then always selects the the factory with a dry immersion heater. The
optimum operating mode – heat pump or heat hybrid version with indirect coil (type T2H) can
generator – taking into account energy prices also be retrofitted with an immersion heater.
and primary energy factors. The heat pump This immersion heater is limescale-resistant,
preheats the water and, if necessary, the heat and it is not necessary to drain the cylinder if
generator is used for reheating. This ensures it has to be replaced.
maximum DHW convenience at all times.
DHW heat pump for outdoor air and recirculation air mode with enamelled DHW cylinder
(300 l cylinder capacity)
High level of DHW convenience with perfectly hygienic water at temperatures of up to 70 °C –
type T2E with immersion heater (1.5 kW) or type T2H with heat generator
Type T2H: intelligent hybrid control for economically or ecologically optimised operation
Low operating costs thanks to highly efficient refrigerant circuit
Low noise emissions thanks to special silent mode
DHW heated to a maximum temperature of 70 °C (up to 65 °C via heat pump module and up to 70 °C
with immersion heater or heat generator)
Quick heat-up function with immersion heater
Installation in rooms with low ceilings (up to 2 m)
Smart Grid ready (SG ready)
Prepared for optimised consumption of power generated on site by photovoltaic systems –
two-stage function possible (heat pump and immersion heater)
Dehumidification of basement rooms in existing buildings (recirculation air mode)
1
2
6 Vitocal 300-A
5
4
3 1 Evaporator
2 Fan
3 Compressor stage 2
4 Compressor stage 1
5 Refrigerant receiver
6 Optional pipework assembly
for connection at the side
54/55
VITOCAL 300-A
Vitocal 300-A – the highly efficient air source heat pump up to 50 kW –
up to 250 kW output possible with a five-appliance cascade.
* Energy efficiency class as per Regulation (EU) No. 811/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
56/57
Master/slave pack each with the Type BW/BWS BW/BWS BW/BWS BW/BWS BW/BWS
same rated heating output 301.B06 301.B08 301.B10 301.B13 301.B17
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 11.4 15.2 20.8 26.0 34.4
Vitocal 200-G
Vitocal 200-G Type BWC 201.A06 BWC 201.A08 BWC 201.A10 BWC 201.A13 BWC 201.A17
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 5.6 7.6 9.7 13.0 17.2
COP ¡ in heating mode 4.4 4.4 4.4 4.5 4.5
Maximum flow temperature °C 60 60 60 60 60
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.20 1.45 1.70 2.20 2.90
– Global warming potential (GWP) 2088 2088 2088 2088 2088
– CO2 equivalent t 2.5 3.0 3.6 4.6 6.1
Dimensions
Length (depth) mm 845 845 845 845 845
Width mm 600 600 600 600 600
Height (control unit open) mm 1049 1049 1049 1049 1049
Weight kg 113 117 129 135 148
Energy efficiency class* A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
* Energy efficiency class as per Regulation (EU) No. 811/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Specification Brine/water heat pumps
* Energy efficiency class as per Regulation (EU) No. 811/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
58/59
Performance data
Cooling capacity subject to the heat pump output
for Vitocal 343-G/333-G/300-G/242-G/222-G/200-G kW Approx. 1.25 – 5.0
Dimensions
Length (depth) mm 520
Width mm 580
Height mm 420
Dimensions
Length (depth) mm 717
Width mm 350
Height mm 973
Weight kg 80
Specification Split air source heat pumps
Vitocal 200-S
Weight
Outdoor unit kg 94 94 99 137 148 148 148
Indoor unit type AWO-M-E-AC, AWO-E-AC kg 44 44 44 45 45 45 45
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.8 1.8 < 2.4 3.6 3.6 3.6 3.6
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO 2 equivalent t 3.8 3.8 < 5.0 7.5 7.5 7.5 7.5
Energy efficiency class* A++ / A+ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
60/61
Vitocal 222-S
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.8 1.8 2.39 3.6 3.6 3.6 3.6
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO2 equivalent t 3.8 3.8 < 5.0 7.5 7.5 7.5 7.5
Cylinder capacity litres 220 220 220 220 220 220 220
Weight
Indoor unit kg 169 169 169 170 170 170 170
Outdoor unit kg 94 94 99 137 148 148 148
Energy efficiency class* A++ / A+ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
Draw-off profile L L L L L L L
Efficiency class A A A A A A A
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Specification Air source heat pumps
Vitocal 350-A
Vitocal 350-A (outdoor installation) Type AWHO 351.A10 AWHO 351.A14 AWHO 351.A20
Vitocal 350-A (indoor installation) Type AWHI 351.A10 AWHI 351.A14 AWHI 351.A20
Refrigerant circuit
Refrigerant R407C R407C R407C
– Refrigerant charge kg 4.0 4.5 5.2
– Global warming potential (GWP) 1774 1774 1774
– CO2 equivalent t 7.1 8.0 9.2
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
62/63
Vitocal 300-A
Performance data
Rated heating output
Operating point A2/W35 (to EN 14511) kW 7.4 7.0 8.5
Operating point A–7/W35 (to EN 14511) kW 7.0 10.5 12.0
Output range min./max. kW 5.8 – 9.7 5.8 – 12.0 7.2 – 13.4
Coefficient of performance ¡ (COP) A2/W35 4.0 3.9 3.9
Coefficient of performance ¡ (COP) A7/W35 5.0 5.0 5.0
Rated cooling capacity
Operating point A35/W18 (to EN 14511) kW 8.1 8.1 9.0
Refrigerant circuit
Refrigerant R410A R410A R410A
– Refrigerant charge kg 4.75 4.75 4.75
– Global warming potential (GWP) 2088 2088 2088
– CO2 equivalent t 9.9 9.9 9.9
Total dimensions
Length (depth) x width x height mm 1100 x 1100 x 1980
Vitocal 200-A
Performance data
Rated heating output
Operating point A2/W35 (to EN 14511) kW 5.0 7.0
Operating point A–7/W35 (to EN 14511) kW 7.5 10.1
Output range min./max. kW 2.6 – 8.3 2.9 – 12.4
Coefficient of performance ¡ (COP) A2/W35 3.8 3.5
Coefficient of performance ¡ (COP) A7/W35 4.8 4.7
Rated cooling capacity
Operating point A35/W18 (to EN 14511) kW 5.3 8.8
Energy efficiency ratio EER 3.2 3.2
Refrigerant circuit
Refrigerant R410A R410A
– Refrigerant charge kg 2.2 3.2
– Global warming potential (GWP) 2088 2088
– CO2 equivalent t 4.6 6.7
Dimensions
Length (depth) x width x height mm 800 x 700 x 1850
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Specification Air source heat pumps
Weight
Outdoor unit kg 102 102 103 145 153 153 153
Indoor unit type AWO-M-E-AC, AWO-E-AC kg 41 41 41 41 41 41 41
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.4 1.4 1.4 2.4 2.4 2.4 2.4
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO2 equivalent t 2.9 2.9 2.9 5.0 5.0 5.0 5.0
Energy efficiency class* A++ / A+ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
64/65
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.4 1.4 1.4 2.4 2.4 2.4 2.4
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO 2 equivalent t 2.9 2.9 2.9 5.0 5.0 5.0 5.0
Cylinder capacity litres 220 220 220 220 220 220 220
Weight
Indoor unit kg 164 164 164 164 164 164 164
Outdoor unit kg 102 102 103 145 153 153 153
Energy efficiency class* A+ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
Draw-off profile L L L L L L L
Efficiency class A A A A A A A
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Vitocal 262-A DHW heat pump
Refrigerant circuit
Refrigerant R134a R134a
– Refrigerant charge kg 1.35 1.35
– Global warming potential (GWP) 1430 1430
– CO2 equivalent t 1.93 1.93
* Energy efficiency class to Regulation (EU) No. 813/2013 for water heaters
** Details for heat pump operation only
66/67
Vitocal 300-A
Performance data
Rated heating output
Operating point A2/W35 (to EN 14511) kW 11.3 – 19.6 16.8 – 29.3 26.4 – 50.0
Operating point A–7/W35 (to EN 14511) kW 9.10 – 16.7 13.5 – 23.8 21.2 – 39.2
COP ¡, two-stage operation
Operating point A2/W35 (to EN 14511) 3.7 3.8 3.6
Operating point A7/W35 (to EN 14511) 4.4 4.4 4.1
Refrigerant circuit
Vitocal 300-A Refrigerant R404A R404A R417A
(AWO 302.A25 and AWO 302.A40) – Refrigerant charge kg 10.2 11.8 20.9
– Global warming potential (GWP) 3922 3922 2346
– CO2 equivalent t 40.0 46.3 49.0
Total dimensions
Length (depth) mm 955 955 1000
Width mm 1600 1735 1900
Height mm 1940 2100 2300
* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
System technology Everything from a single source
"The whole is greater than the sum of its Viessmann system technology incorporates
parts." In accordance with this philosophy, everything you need for a reliable and
Viessmann does not simply supply individual economical heating system.
heating equipment components that meet
the high Viessmann standards for quality, This includes the Vitotronic control unit with
reliability and effectiveness. In addition, wireless remote control and online control
all products are part of a matching overall using the ViCare app, powerful Vitocell DHW
concept, where all components complement cylinders for the highest DHW convenience,
one another. After all, only perfect interaction and high grade photovoltaic systems.
between all system parts can draw out the
maximum potential of our innovative leading
technology.
68/69
Operating convenience
Clear, convenient, intelligent: the Vitotronic
offers perfect functionality for fast and precise
control of any heating system.
Connectivity
With Vitoconnect and a smartphone,
controlling Viessmann heating systems
couldn't be easier. Heating systems can be
controlled with the ViCare app (page 8/9). All
apps are available for mobile devices running
iOS or Android operating systems.
Photovoltaic systems
The sun supplies more power than we need.
This is economical – generating solar power
is already significantly cheaper than drawing
domestic power from the grid.
DHW cylinders
DHW convenience for every demand:
Vitocell DHW cylinders are convenient
solutions for supplying a household with hot
water – the perfect complement to any new
heat pump.
Scan the QR code to
receive further information
about the Vitocell
System accessories
In addition to the high quality Viessmann
products, we also offer system components
from other well known manufacturers with
the Vitoset range of accessories. Radiators,
expansion vessels, pipework, pumps, filters
and valves – Vitoset offers the complete range Scan the QR code to
of accessories for your Viessmann heating discover more about the
system. Viessmann radiator range
System technology Efficient on-site consumption of solar power by a heat pump
If you intend to combine a PV system with a The economic viability of the photovoltaic
heat pump, select an appliance that optimises system is substantially increased thanks to
on-site consumption and can be adapted to the deliberate increase in the proportion of
match the power generating characteristics of on-site consumption. Using low cost solar
the PV system. For this purpose Viessmann power also makes the heat pump more
has developed a suitably matched system economically attractive.
comprising PV and heat pump.
The Vitocharge power storage system Actual charging and operating
conditions of the Vitocharge can be
Optimised system concept offers independence from the public
viewed on the display.
with Viessmann heat pumps electricity grid
Via an energy meter, the heat pump control The Vitocharge power storage system rounds
unit detects whether the PV system is off the energy system. It enables power to
supplying sufficient amounts of power – be supplied exactly when it is needed. This
which is then used by the heat pump to heat makes efficient, decentralised power supply
DHW and heating water. The heat gained with high levels of on-site consumption and
during the day via photovoltaic technology is self-sufficiency a reality. Viessmann is the
stored in a well-insulated cylinder and can be only manufacturer to supply all products
used for domestic hot water and heating as from a single source, so that users can
and when required. make effective and economical use of the
power they generate. This offers the user
The Vitotronic 200 control unit automatically independence from the public electricity grid.
increases the on-site consumption of solar
power. Combining the Viessmann heat pump The Vitocharge is charged when there is surplus
with a photovoltaic system also offers the power. As soon as more power is needed again,
option of integrating additional components this additional energy is delivered from the
that increase on-site consumption of the battery. When combined with a PV system,
solar power generated, such as ventilation the energy generated during the day can be
equipment, for example. Before the heat pump stored. At night, an electric vehicle can be
is activated, priority is given to meeting charged, for example, so that it is ready to be
the power demand for electrical household driven in the morning.
appliances with the solar power generated
on site. After the demand from household Self-generated power for the heat pump
appliances has been satisfied, an energy Another particularly effective way to save
meter records the amount of solar power energy is by enabling interaction between a
remaining and communicates this to the heat heat pump, PV system and Vitocharge. This
pump. Using the heat pump, the solar surplus involves the electrical components in the heat
can then be stored in the form of thermal pump being operated with power generated
energy and made available when it is required. on site.
This raises the level of on-site consumption
and makes use of the solar energy while it is
available.
Property developers and system users can Every system user benefits from the
receive advice and support regarding sales, comprehensive service that all installation
installation and customer service exclusively contractors offer as standard.
via Viessmann trade partners, who complete
regular training at the Viessmann Academy,
and have an in-depth knowledge of the
company's products.
72/73
The company
Viessmann Group