Heating with airborne and geothermal energy –


making the best possible use of renewables

This brochure provides detailed information on sustainable and environmentally


responsible heat generation using heat pumps from Viessmann.

Heat pumps utilise renewable energy from the ground, sun, groundwater or air.
They lower consumption of fossil fuels, conserve valuable resources and reduce
CO2 emissions that damage the environment.

Viessmann heat pumps offer their users an additional benefit – many of them
feature active and natural cooling functions. Alongside their classic application as
heat generators on cold days, they can also create a pleasant interior in summer by
bringing refreshing cool air into the house.

Viessmann's extensive product range offers the right heat pump to suit every
demand. Even at the design stage, structural and geological conditions, as well
as personal and individual preferences concerning the heat demand can be taken
into account. Running a heat pump with power generated on site by a photovoltaic
system is particularly environmentally responsible and very affordable.

Viessmann heat pumps can be used in new build and modernisation projects,
operated together with solar thermal systems and even combined with an existing
oil or gas heating system to form a multi mode system. This allows every building
and property owner to put their plans into action in the most efficient way possible.
Contents
4/5

Heat pumps from Viessmann offer tailor-made solutions for central heating and cooling, as
well as convenient hot water supply, for both new build and modernisation projects.

Saving energy and protecting the climate from page 6

By modernising your heating system, you are making an active


contribution towards protecting the climate and saving fossil fuels.

Brine/water heat pumps from page 12

Brine/water heat pumps use the ground as their primary energy


source, either with geothermal collectors or geothermal probes.

Air source heat pumps from page 34

Air source heat pumps utilise outdoor air or extract air as a


primary energy source.

System technologies designed to work together from page 68

System technology from Viessmann perfects your new


heating system: Vitotronic control units and Vitocell DHW
cylinders as well as high grade solar technology for cost effective
domestic hot water heating and central heating backup.

Service that covers every aspect of heating from page 72

Viessmann trade partners can advise you on everything you


need to know about innovative heating technology, available
subsidies and finance options, without obligation and free of
charge.

The company
from page 74
The power of innovation: a family business for three generations,
Viessmann offers state of the art technology and takes its
responsibilities seriously.
How it works

Energy from the ground Energy from the ground


(collector) (probe)

1 2 3 1 2 3

Energy from the ground, air and sun Energy from groundwater
(Vitofriocal ice store system)

1 2 3
1

Energy from the air Energy from the air


(with outdoor unit)

1 2 3 1 2

1 Vitocal heat pump 2 DHW cylinder 3 Heating water buffer cylinder

4 Ice store 5 Solar/air absorber 6 Outdoor unit


6/7

Viessmann heat pumps are recommended for


new build and modernisation
The air, ground, water and waste heat are primary energy sources that are practically free
and can be used to run a heat pump system efficiently.

Heat pumps work like a refrigerator, just in „ Air – unlimited availability; lowest
reverse. While a refrigerator directs heat to investment outlay
the outside, heat pumps take energy from the „ Ground – via geothermal collector,
air or the ground and transfer it into the living geothermal probe or ice store; very
space via the heating system. The transfer efficient
medium carrying the heat drawn from the „ Water – extremely efficient; observe water
environment is compressed in order to reach quality
the flow temperatures necessary for different „ Waste heat – subject to availability, amount
heating systems. and temperature level

For example, a heating system with radiators Annual coefficient of performance


requires temperatures of up to 70 °C. When designing a system, it is necessary
Underfloor heating systems, however, to consider its likely use over an entire year.
manage with a flow temperature of 30 °C. To do this, the amount of heat delivered is
This makes heat pumps suitable for both compared with the total electricity demand
modernisation and new build. of the heat pump system. This includes the
power drawn by pumps and control units,
State of the art compressor technology etc. The result is referred to as the annual
for the highest level of efficiency coefficient of performance (COP).
The compression process is critical for the
efficiency of a heat pump. Viessmann uses the The annual COP is the ratio of heat transfer
most advanced components in its heat pumps. to power consumption. The higher this
Their operation is characterised by quiet coefficient, the more efficiently the heat pump
running, low vibrations and an extremely long is working.
service life without the need for maintenance.

To generate heat, thermal energy is extracted


from the environment and used to evaporate
a refrigerant that boils at a low temperature.
The compressor compresses the gas this
creates and raises it to a higher temperature
level. Heat pump

A heat exchanger transfers the energy from


the heated gas to the heating circuit. The
refrigerant, which is still under pressure,
condenses again and is expanded in an Compression process
expansion valve. The cycle then begins again.

Use with various energy sources 65 °C


The best energy source for each individual
case depends on local conditions and the
actual heat demand. Viessmann heat pumps
can use various energy sources:
Ground
Temperature all year round between 5 and 18 °C (at 2 m depth)

Getting hotter towards the centre: at an initial temperature of between 5 and 18 °C, a flow temperature of up
to 72 °C is reached.
Connectivity ViCare app
Vitoconnect

The ViCare app offers you a


convenient way to operate your
heating system and save energy –
anytime, anywhere. It allows you to
keep an eye on the system status at
all times. You can set the required
room temperature with a single
swipe; one tap of the screen allows
you to select a daily template and
save energy automatically.
WLAN Vitoconnect Heat generator

ViCare accesses the Vitoconnect online interface to control


the heat generator. Once the system user has given their
consent, the contractor can use Vitoguide to keep a constant
eye on their customer's system.
8/9

The quick and easy way to save energy


Enjoy energy savings, convenience and reassurance

The ViCare app offers new possibilities for Yellow lets you know about a pending service
controlling heating systems via the internet. and red automatically offers to contact the
The design of the ViCare graphic interface contractor.
has been kept simple, enabling completely
intuitive heating system operation. This requires consent from the system user,
which can be granted within the app with
Save energy automatically just two taps. The connection to the trade
The system is designed to control one partner's software is then established and
heating circuit. You can set the required room they can view the system data, in order to Vitoconnect with sockets for the
plug-in power supply unit (left) and
temperature via the touchscreen, and switch provide their customer with quick and
data connection
between standard and party mode efficient support.
("I'm home longer") with a single tap.
Vitoconnect internet interface
When leaving the house ("I'm away"), it takes Vitoconnect is the interface between the 5 year guarantee*
just one command to reduce the heating boiler and ViCare. It is not only compatible with system web connection/
system to a lower temperature and therefore with new Viessmann heating systems, but is connectivity
save energy. Anyone wanting to program also available for many existing appliances.
different switching times for each day will It is connected directly via a cable. A plug-in * For conditions see
www.viessmann.de/garantie
appreciate the assistant function. power supply unit is included in the standard
delivery. A small accessory, measuring only
A separate button on the start screen shows 10 x 10 cm, is available for wall mounting.
the current outside temperature and, with just
one tap, the temperature history over the last Connect the module to the internet and
few days. register via plug & play. Simply scan the
supplied QR code using a smartphone.
System status at a glance Installation and commissioning is then
The user can see at a glance whether their usually completed in just a few minutes.
heating system is working as it should.

Explore the app in advance –


no need to register!
Simply download the app and tap
Reassurance Economy Support "Discover ViCare" on the app's start
screen – and off you go, with no
Warmth and reassurance Simply set your preferred A direct link to the contractor – just
need for an actual heat generator or
„ Green for go – see at a glance temperature – save costs when in case
internet connection.
whether everything is OK you're not at home „ Simply enter the contact details of
„ Be informed about a pending „ Straightforward, convenient the contractor
service operation of the heating system „ Quick and effective assistance
„ Direct access to the address of the „ Record your daily routine and – the contractor has all of the
saved contractor automatically save on energy costs important information
„ Set standard functions at the tap of „ All-inclusive carefree safety and
a button on your smartphone maintenance package
ViCare app
Product range Brine/water heat pumps
5.7 to 85.6 kW

Heat source Application Integral Cooling Page


DHW function
Ground Water Ice store Detached Apartment Comm- High cylinder
system house building ercial temp- NC/AC
premises erature

Vitocal 333-G Q Q Q Q Q/ – 14


Vitocal 343-G Q Q Q Q Q/ – 14
5.7 to 10.4 kW

Vitocal 222-G Q Q Q Q1) / – 16


Vitocal 242-G Q Q Q Q1) / – 16
6.1 to 10.0 kW

Vitocal 300-G Q Q Q Q Q Q1) / Q1) 20


5.7 to 17.2 kW (single stage)
11.4 to 34.4 kW (two-stage)

Vitocal 200-G Q Q Q Q1) / – 22


5.6 to 17.2 kW

Vitocal 350-G Q Q Q Q Q Q1) / Q1) 26


20.5 to 42.3 kW (single stage)
41.0 to 84.6 kW (two-stage)

Vitocal 300-G Q Q Q Q Q1) / Q1) 28


21.2 to 42.8 kW (single stage)
42.4 to 85.6 kW (two-stage)

1)
Accessories required
Air source heat pumps 10/11

2.3 to 50.0 kW

Model Application Integral Cooling Page


DHW function
Monoblock Split Detached Apartment New Modern- cylinder
indoor/outdoor house building/ build isation
installation commercial AC
premises

Q Q Q Q 36/38
Vitocal 200-S/222-S
2.3 to 12.0 kW

Q Q Q Q 42
Vitocal 350-A
10.6 to 18.5 kW

Q Q Q Q Q 44
Vitocal 300-A
5.8 to 13.4 kW

Q Q Q Q 46
Vitocal 200-A
2.6 to 12.4 kW

Q Q Q Q Q 48/50
Vitocal 200-A/222-A
2.3 to 12.0 kW

Q Q Q Q Q 52
Vitocal 262-A
300 litres

Q Q Q Q 54
Vitocal 300-A
11.3 to 50.0 kW (two-stage)
Brine/water
heat pumps
12/13

VITOCAL 333-G NC/333-G/343-G


VITOCAL 222-G/242-G
Compact, floorstanding heat pumps that take up little space and are particularly quiet in
operation – making them suitable even for installation near the living space.

Three versions of the compact brine/water Small footprint


heat pumps are available: with or without The small footprint of these heat pumps makes
solar thermal connection, and with integral them particularly suitable where space is at a
natural cooling (NC) function. DHW cylinders premium – the brine circulation pump, heating
with 170 litre capacity (solar version with circuit pump and 3-way diverter valve are
220 litres) are integrated to safeguard high already integrated inside the compact casing.
DHW convenience. At the core of the The casing completely protects the refrigeration
appliance is a high efficiency heat pump module/hydraulic compartment from the
module. outside environment and, in conjunction with
the three-dimensional anti-vibration mounts,
These compact appliances are particularly minimises operating noise. These compact
economical thanks to the refrigerant circuit heat pumps are some of the quietest in their
with electronic expansion valve (EEV) and the category, as they generate a sound power level
Viessmann-developed RCD (refrigerant cycle of only 38 dB(A) at B0/W35.
diagnostic) system, plus the standard energy
saving high efficiency pumps. This is reflected For easier handling, the casing was
in high annual coefficients of performance designed to be split into sections. A variety Energy efficiency label
Vitocal 333-G, BWT 331.B06
and low running costs throughout the entire of connection accessories facilitate the
service life of the appliance. installation of the heat pump, which is
supplied fully fitted ex works.

EHPA Quality Label as proof of


the COP, for subsidy according
to the German market incentive
programme

Take advantage of these benefits

„ Compact brine/water heat pumps with heating outputs from 5.7 to 10.4 kW
„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511
of up to 5.0 (B0/W35)
„ Easy to use Vitotronic control unit with plain text display
„ Ready to connect, ex works
„ Prepared for the use of power generated on site, for example by photovoltaic systems
„ Web-enabled via free ViCare app and Vitoconnect (optional)
Brine/water VITOCAL 333-G NC / VITOCAL 333-G
heat pumps VITOCAL 343-G
5.7 to 10.4 kW

7
4 Vitocal 333-G

5 1 DHW cylinder, 170 litre capacity


2 Vitotronic 200 heat pump control unit
3 Indirect coil for cylinder heating
6 4 Primary pump (high efficiency pump)
8 5 Secondary pump (high efficiency pump)
6 Hermetically sealed Compliant scroll
compressor
7 Diverter valve, central heating/DHW
8 Integral instantaneous heating water heater
14/15

Vitocal 343-G and Vitocal 333-G compact


brine/water heat pumps were developed as
small, highly efficient solutions for new build.
This involved the use of generously sized
heat exchangers to achieve a high coefficient
3
of performance (COP) of up to 5.0, in
accordance with EN 14511, at B0/W35.

The annual coefficient of performance


specifies the relationship between the heat
volume (heating energy) transferred and the
energy (drive energy) drawn, over the course 2
of a year. The innovative RCD (refrigerant
cycle diagnostic) system plays a vital role in 5
raising the annual coefficient of performance.
It ensures that the heat pump operates with 4
optimum efficiency at every operating point. 1

In addition, energy saving, high efficiency


pumps for the brine and heating circuits Vitocal 343-G compact brine/water heat pump
ensure very low running costs and therefore with solar thermal system
a high annual coefficient of performance in all
three output sizes. 1 Compact heat pump
(brine/water)
With solar cylinder or natural cooling 2 Underfloor heating system
Vitocal 343-G is designed for the connection 3 Vitosol solar collectors
of a solar thermal system for DHW heating. 4 Geothermal probe
A generously sized solar cylinder with 220 litre 5 Solar-Divicon pump module
capacity and a solar control unit have been
integrated into the appliance for this purpose.
The Vitotronic control unit with
large, multi line, graphic display
In the compact Vitocal 333-G, a DHW cylinder
can also show the solar yield.
with 170 litre capacity ensures a convenient
supply of hot water. To help you keep cool on
hot summer days, the Vitocal 333-G is also
available with a natural cooling (NC) function.

Take advantage of these benefits

„ Compact brine/water heat pumps with heating outputs from 5.7 to 10.4 kW
„ High DHW convenience through integral DHW cylinder with 220 litre capacity
(Vitocal 343-G) and 170 litre capacity (Vitocal 333-G NC/333-G)
„ Very quiet thanks to an innovative sound attenuation concept resulting in a sound power level
of 38 dB(A) at B0/W35
„ Flow temperature: up to 65 °C for high DHW convenience
„ Power saving high efficiency pumps
„ Control of a Vitovent 300-F mechanical ventilation unit
„ Integral natural cooling (NC) function for the Vitocal 333-G NC
„ Instantaneous heating water heater as standard

For specification, see page 56


Brine/water VITOCAL 222-G
heat pumps VITOCAL 242-G
6.1 to 10.0 kW

8 Vitocal 242-G

6
1 Heating lance
7 2 Enamelled DHW cylinder
3 Vitotronic 200 heat pump control unit
4 Integral solar indirect coil
9 5 Modulating cylinder loading pump
6 Primary circulation pump
7 Secondary circulation pump
8 Diverter valve, central heating/DHW
9 Integral instantaneous heating water heater
16/17

Vitocal 242-G and Vitocal 222-G compact


brine/water heat pumps are fully equipped
with all of the components required for
DHW and central heating.

With heating output levels of between 6.1 and


10.0 kW, they are ideal for use in detached
houses. Flow temperatures up to 60 °C also
enable use with conventional radiators.

The two heat pumps are attractively priced


alternatives to the compact appliances in the
300 series. Equipped with a Compliant scroll
compressor and a thermostatically controlled
expansion valve, they achieve coefficients of
performance of up to 4.5 (to EN 14511 at Easy to operate Vitotronic control
unit with straightforward navigation
B0/W35).
and clear menu tree.

Vitocal 242-G prepared for solar operation


Vitocal 242-G is fully prepared for the
connection of a solar thermal system for Particularly quiet operation
DHW heating. A 220 litre solar cylinder and The sound-optimised appliance design makes
a solar control unit enable high solar yields these compact heat pumps particularly quiet
to be achieved. so that they can even be installed close to the
living space.
Vitocal 222-G with large DHW cylinder
The Vitocal 222-G compact heat pump offers Natural heating – natural cooling
a high level of DHW convenience thanks to its The compact heat pumps can provide a
170 litre DHW cylinder, which is heated via an pleasant indoor climate in a low energy
internal indirect coil. house, even on hot summer days. The natural
cooling function brings cool underground
temperatures into the home. For this,
the Viessmann NC-Box is required as an
accessory.

Take advantage of these benefits

„ Compact brine/water heat pumps with heating outputs from 6.1 to 10.0 kW
„ High DHW convenience through integral DHW cylinder with 220 litre capacity (Vitocal 242-G) and
170 litre capacity (Vitocal 222-G)
„ Very quiet thanks to the sound-optimised appliance design with a sound power level of 43 dB(A) at
B0/W35
„ Flow temperature: up to 60 °C
„ Natural cooling (NC) function with optional NC-Box
„ Instantaneous heating water heater as standard

For specification, see page 54


Brine/water
heat pumps
18/19

VITOCAL 300-G
VITOCAL 200-G
Flexible configuration of Viessmann heat pumps: either brine/water heat pump, or
water/water heat pump with conversion kit, depending on the primary energy source

The floorstanding Vitocal 300-G and Vitocal As an alternative, depending on the location
200-G brine/water heat pumps recover heat of the house, it may also be possible to
from high yielding heat sources. For this utilise the thermal energy contained in the
purpose, a geothermal probe, geothermal groundwater. In addition, the Vitocal 300-G
collector or Vitofriocal ice store system is can also be configured for straightforward
installed on the property. In all these cases, operation as a water/water heat pump. They
these appliances cover the entire energy are equally well suited to new build and
demand, even on colder days. modernisation, in both detached houses and
apartment buildings.

Energy efficiency label


Vitocal 300-G, BW 301.B10

EHPA Quality Label as proof of


the COP, for subsidy according
to the German market incentive
programme

Take advantage of these benefits

„ Year-round mono mode operation for DHW and central heating possible
„ Vitocal 300-G: low operating costs with the highest level of efficiency at every operating point due
to the innovative refrigerant cycle diagnostic (RCD) system with electronic expansion valve (EEV)
„ Prepared for the use of power generated on site, for example by photovoltaic systems
„ Web-enabled via free ViCare app and Vitoconnect (optional)
„ Control of Viessmann ventilation units possible
„ Easier handling through small and light modules
Brine/water VITOCAL 300-G
heat pumps 5.7 to 17.2 kW (single stage)
11.4 to 34.4 kW (two-stage)

Vitocal 300-G heat pump with Vitocharge power storage


system and Vitocell 100-V DHW cylinder

4 Vitocal 300-G

1 Vitotronic 200 heat pump control unit


5 2 Condenser
3 Large area evaporator for an efficient
exchange of heat
4 High efficiency pump
5 Hermetically sealed Compliant scroll
compressor
20/21

With five output stages, the Vitocal 300-G


brine/water heat pump can be used to cover
the heat demand required for a number of
different heating systems.

Modular solution for higher heat demand


Where there is a higher heat demand, the
two-stage Vitocal 300-G, based on the
master/slave principle, is the right choice.
It can also be configured for ground or
groundwater as the heat source. Two heat
pumps can be linked together if a higher
heating output is required. The modular
design, with separate compressor circuits,
also ensures particularly high levels of
efficiency in partial load operation, and
enables simultaneous DHW and central
heating. The master module regulates the
slave module.

Reliable and quiet


The powerful Compliant scroll compressor
fitted in the Vitocal 300-G heat pump is Vitocal 300-G two-stage
heat pump (master/slave)
outstanding on account of its high operational
safety, reliability and especially quiet
operation. To achieve this, the appliance is The refrigerant cycle diagnostic (RCD) system
equipped with dual anti-vibration mounts to constantly monitors the refrigerant circuit in
prevent structure-borne noise transmission the Vitocal 300-G and, in conjunction with
and insulate the casing against airborne noise. the electronic expansion valve, ensures the
At the same time, the compressor guarantees highest efficiency at every operating point,
the highest coefficient of performance (COP which results in high annual coefficients of
up to 5.0) and flow temperatures up to 65 °C. performance.

Vitotronic 200 with energy statement


facility
The Vitotronic 200 is straightforward and
intuitive to operate, thanks to the plain text
user prompts and graphic display. Amongst
other features, it enables a differentiated
energy statement, which is accepted by
subsidy bodies [in Germany].

Take advantage of these benefits

„ Floorstanding brine/water heat pumps


Single stage heating output: 5.7 to 17.2 kW, two-stage heating output: 11.4 to 34.4 kW
„ Heating output in water/water configuration: 7.5 to 42.2 kW
„ Flow temperature: up to 65 °C
„ Control via mobile devices and the Vitotrol app

For specification, see page 57


Brine/water VITOCAL 200-G
heat pumps 5.6 to 17.2 kW

2
3

4 Vitocal 200-G

1 Vitotronic 200 control unit


5 2 Condenser
3 Large area evaporator for an efficient
exchange of heat
4 High efficiency pump
5 Hermetically sealed Compliant scroll
compressor
22/23

With its good price/performance ratio, the


Vitocal 200-G compact brine/water heat pump
is ideally suited to new build detached and
two-family houses. Its innovative technology,
with efficient Compliant scroll compressor,
enables it to achieve a maximum flow
temperature of 60 °C.

Two heating circuits for tailored heating


convenience
The heat pump meets all the requirements for
a newly built detached or two-family house.
The Vitotronic 200 weather-compensated
control unit allows two separate heating
circuits to be integrated.

Prepared for subsidies


If an optional heat meter is installed, the
purchase of a Vitocal 200-G may be eligible Vitotronic 200 control unit

for public subsidies [in Germany], as it meets


the requirements of the German market
incentive programme.

Straightforward installation Cooling and ventilation


The Vitocal 200-G is delivered as standard The natural cooling function is already
complete with integral high efficiency pumps included. To use this, the Vitocal 200-G must
for the brine and heating circuits, a circulation be equipped with an NC-Box (accessory). The
pump for cylinder heating, and a safety Vitotronic 200 can also be used to control the
assembly. Vitovent 300-F ventilation unit.

Vitotronic 200 control unit with optional Prepared for photovoltaic power
app control The Vitocal 200-G heat pump is already
The Vitotronic 200 control unit, with plain text prepared for the utilisation of more affordable
and graphic display, is simple and intuitive power generated on site by a photovoltaic
to use. Settings can quickly be changed via system. An intelligent controller increases
the menu. Control via the internet through on-site consumption of power generated by
the Vitotrol app on a mobile device is also an the PV system.
option.

Take advantage of these benefits

„ Floorstanding brine/water heat pump


Single stage heating output: 5.6 to 17.2 kW
„ Flow temperature: up to 60 °C
„ Control via mobile devices and the Vitotrol app

For specification, see page 57


Brine/water
heat pumps
24/25

VITOCAL 350-G
VITOCAL 300-G
Powerful heat pumps with high flow temperatures meet the requirements for
high DHW convenience in large detached houses and apartment buildings.

With its two high temperature heat pumps, the Perfect for high heating output
Vitocal 350-G and Vitocal 300-G, Viessmann The Vitocal 350-G/300-G is an economical
also meets the demand for higher heating solution for higher heat demands. It allows
outputs. Four sizes are available up to 84.6 kW. the heating flow and return lines of several
heat pumps to be linked in a cascade.
EVI for high flow temperatures
The Vitocal 350-G achieves high flow A heat pump cascade consists of one lead
temperatures of up to 70 °C. This results from heat pump and up to four lag heat pumps.
the use of an EVI (enhanced vapour injection) Both the lead heat pump and the lag heat
refrigerant circuit, where an intermediate pumps can have two stages. This not only
vapour injection cools the refrigerant so that delivers the higher heating output required,
it can be more densely compressed than is but also increases the operational reliability of Energy efficiency label
Vitocal 300-G, BW 301.A21
otherwise possible. the entire system.
The Vitocal 350-G also delivers sufficiently
high temperatures to make it suitable for The modular design, with separate
modernising apartment buildings with radiator compressor circuits, also ensures particularly
heating systems. high levels of efficiency in partial load
operation, and enables simultaneous DHW
RCD system for highest level of efficiency and central heating.
RCD stands for refrigerant cycle diagnostic
system. This provides constant monitoring of
the refrigerant circuit in Vitocal high EHPA Quality Label

temperature heat pumps and, in conjunction as proof of the COP,


for subsidy according
with the electronic expansion valve, ensures
to the German market
the highest level of efficiency at every incentive programme
operating point.

Take advantage of these benefits

„ Low noise and vibration emissions through sound-optimised appliance design


„ Low operating costs with the highest level of efficiency at every operating point through the
innovative RCD (refrigerant cycle diagnostic) system with electronic expansion valve (EEV)
„ Mono mode operation for DHW and central heating possible
„ Master/slave solutions for higher heat demands and DHW convenience, e.g. combination of
Vitocal 300-G and Vitocal 350-G
„ Extremely quiet operation through sound-optimised appliance design
„ Vitotronic 200 control unit with plain text and graphic display for weather-compensated heating
mode and natural or active cooling
„ Control of Viessmann ventilation units possible
„ Prepared for the use of power generated on site, for example by photovoltaic systems
„ Web-enabled via free ViCare app and Vitoconnect (optional)
Brine/water VITOCAL 350-G
heat pumps 20.5 to 42.3 kW (single stage)
41.0 to 84.6 kW (two-stage)

Vitocal 350-G
(master)

1 Vitotronic 200 control unit


2 Condenser
3 Large area evaporator for an efficient
exchange of heat
4 Hermetically sealed Compliant scroll
compressor with EVI (enhanced vapour
injection) process
26/27

The powerful Vitocal 350-G brine/water heat Furthermore, the Vitotronic 200 is capable
pump is one of the quietest heat generators of of communicating, and via the Vitocom 300
its kind, thanks to its low-vibration design. module, allows the heat pump system to be
set up, monitored and optimised over the
Where heat demand is even higher, the internet with the Vitotrol app on a smartphone
Vitocal 350-G can be operated in two-stage or tablet.
mode with an additional heat pump of the
same type, or with a Vitocal 300-G in a Operation with solar power generated
master/slave system, and can then provide on site
an output of up to 84.6 kW. As early as at the The Vitocal 350-G heat pump is already
design stage, this system configuration allows prepared for the utilisation of more affordable
for optimum matching of the heat pumps to power generated on site by a PV system.
the heat demand. An intelligent control unit ensures maximum
consumption of self-generated power while
Master/slave system for DHW and lowering energy costs.
central heating
In a master/slave system, the Vitocal 350-G
(master) delivers high flow temperatures for
DHW heating, while the Vitocal 300-G
(slave, without its own control unit) covers
the required heat load.

The EVI refrigerant circuit enables the


Vitocal 350-G to achieve an extremely high
COP of up to 5.0, which contributes to its low
operating costs.

Vitotronic 200 control unit with


communication capability
Viessmann uses the convenient Vitotronic 200
control unit to ensure standardised operation
for all its heat generators. The many functions
of this control unit include operation with
user prompts, an integral diagnostic system,
control of the instantaneous heating water
heater and an additional oil or gas boiler, and
of course, natural and active cooling functions.

Two-stage Vitocal 350-G
(master on the right/slave on the left)
as a brine/water or water/water heat
pump

Take advantage of these benefits

„ Brine/water heat pump


Single stage heating output: 20.5 to 42.3 kW, two-stage: 41.0 to 84.6 kW
„ Water/water heat pump
Single stage heating output: 25.4 to 52.3 kW, two-stage: 50.8 to 117.8 kW
„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511 of up to 5.0 (B0/W35)
„ Flow temperature: up to 70 °C

For specification, see page 56


Brine/water VITOCAL 300-G
heat pumps 21.2 to 42.8 kW (single stage)
42.4 to 85.6 kW (two-stage)

3
4

Vitocal 300-G

5
1 Vitotronic 200 heat pump control unit
2 Condenser
3 Large area evaporator for an efficient
exchange of heat
4 High efficiency pump
5 Hermetically sealed Compliant scroll
compressor
28/29

The Vitocal 300-G is the specialist for large


detached houses and apartment buildings.
For applications with higher heat demands,
the two-stage Vitocal 300-G, based on the
master/slave principle, is the right choice.

Cascades up to 589 kW
It can deliver a heating output from 42.4 to
85.6 kW (brine/water) with ground as the
primary heat source, or 56.2 to 117.8 kW
(water/water) when using groundwater. If this
is not enough, the integral cascade function
enables output to be raised to up to 589 kW
(water/water) with several Vitocal 300-G
units.

This also assures greater operational


reliability for the system as a whole. The
modular design, with separate compressor Two-stage Vitocal 300-G
(master on the right/slave on the left)
circuits, also ensures particularly high levels
as a brine/water heat pump, two-stage:
of efficiency in partial load operation, and
42.4 to 85.6 kW, maximum 428 kW
enables simultaneous central and DHW (as a cascade)
heating.

Powerful and reliable Quiet operation and great performance


At the heart of the Vitocal 300-G lies its are not mutually exclusive
powerful Compliant scroll compressor. This The hermetically sealed casing and particularly
component stands out on account of its high clever appliance design enable a reduction in
degree of operational safety and reliability. In noise emissions in the Vitocal 300-G that far
conjunction with the large heat exchangers and exceeds expectations in this output range.
integral refrigerant manifold, the Vitocal 300-G
achieves a high coefficient of performance and
flow temperatures up to 60 °C.

Take advantage of these benefits

„ Brine/water heat pump


Single stage heating output: 21.2 to 42.8 kW, two-stage: 42.4 to 85.6 kW, maximum: 428 kW
(as a cascade)
„ Water/water heat pump
Single stage heating output: 28.1 to 58.9 kW, two-stage: 56.2 to 117.8 kW, maximum: 589 kW
(as a cascade)
„ Flow temperature: up to 60 °C
„ Sound power level: ≤ 44 dB(A)
„ Integral energy statement
„ Easier handling through small and light modules

For specification, see page 58


Brine/water Vitofriocal ice store system
6.0 to 17.2 kW

A
1
5

B
3

Vitofriocal ice store system


2

A Energy from insolation


6 B Energy from ambient air
C Energy from the ground

1 Solar air absorber


2 Ice store
3 Heat source manager
C
4 Vitocal heat pump
5 NC-Box for natural cooling
30/31

Heating with ice – with the exclusive Vitofriocal


ice store system from Viessmann
This inexhaustible source of energy for brine/water heat pumps uses the energy released
when water freezes to ice and ice melts to water.

The use of an ice store as an energy source is Package solutions for easy installation
an innovative solution. The ice store consists Viessmann is the only heat pump
of a tank with built-in heat exchangers which manufacturer to exclusively offer the
is buried in the garden and filled with ordinary innovative Vitofriocal ice store system. For
tap water. Special solar air absorbers installed heat pumps with a rated heating output from
on the roof of the building draw heat from the 6.0 to 17.2 kW, various standard system
ambient air, as well as from insolation, and packages are currently available which greatly
supply it to the tank. The ice store also draws facilitate the engineering and ordering of
energy directly from the ground. components. These packages comprise an
ice store with built-in heat exchangers, solar
Using crystallisation energy for heating air absorbers with a roof mounting system
The heat pump extracts the energy required and the heat transfer medium for the primary
for DHW and central heating from the water circuit.
in the tank as required. If the temperature in
the tank falls to freezing point, more energy is Larger properties with a greater heat demand
drawn from the freezing effect of the water – require a customised ice store and solar air
hence the term "ice store". absorbers. Viessmann offers the relevant
support for this.
During the transition from water to ice, the
amount of crystallisation energy released No official permits required
is equivalent to that required for the inverse A further benefit of the Vitofriocal ice store
process of thawing. With an ice store that can system: it does not require the costly
hold ten cubic metres – the standard size for drilling that is necessary for accessing
a detached house – this corresponds to the geothermal energy from deep in the ground,
energy content of approx. 120 litres of fuel oil. or the extensive groundwork involved when
embedding geothermal collectors over a
The key difference is that the fuel oil is entirely large area. Nor does it require any official
consumed to generate heat, whilst the water permits, as the ice store has no impact on
content of the ice store can be used time and groundwater.
time again to generate heat using energy from
the sun and air.

Take advantage of these benefits

„ Combined utilisation of ambient air, the ground and insolation as energy sources
„ No drilling – no environmental risk, no permits required
„ Low operating costs thanks to the high COP of the heat pumps of up to 5.0 (B0/W35) to EN 14511
„ Particularly high efficiency thanks to intelligent heat source management and heat pump with RCD
(refrigerant cycle diagnostic) system with electronic expansion valve (EEV)
„ Easy to use Vitotronic control unit integrated in the heat pump
Natural cooling NC-Box
Active cooling AC-Box

NC-Box
Optional equipment for Viessmann
heat pumps to provide passive cooling

AC-Box
Optional equipment for Viessmann
heat pumps to provide active cooling
32/33

Passive and active cooling with heat pumps

Besides generating high levels of heating comfort and reliable DHW heating,
heat pumps can also provide cooling for rooms in hot weather.

In addition to its primary function as a heating Active cooling with AC-Box – efficient
appliance, heat pumps can also provide heating and cooling
cooling using two different methods: The AC-Box combines active and natural
cooling in heat pump systems, thus making
„ With passive cooling (natural cooling), the them even more versatile and convenient. The
brine medium or the groundwater absorbs system changes over automatically according to
the energy from the heating circuit via a the required room temperature. If only a low
heat exchanger and transfers it outdoors. cooling capacity is required, natural cooling
The natural ambient temperature is also is sufficient. However, when that is no longer
used for cooling. Apart from the control enough, active cooling is added.
unit and circulation pump, the heat pump
remains switched off. This makes natural Keeping cool when it's hot outside
cooling a particularly energy efficient and The compressor circuit "kicks in" for active
affordable way to cool the interior of a cooling. Using the AC-Box, the internal control
building. unit reverses the output and input functions
and now actively transfers heat from the
„ With active cooling, the function of the building to the geothermal probe. Cold water
heat pump is simply reversed. For this, then flows through the heating circuit itself –
the refrigerant cycle is reversed internally; cooled down to 7 °C if necessary.
alternatively the primary and secondary
connections are changed over. As with Utilising the energy removed
a fridge, the heat pump then actively Incidentally, direct use can also be made of
generates a cooling capacity. the heat removed from the interior in this
way, for example for DHW heating or to heat
Natural cooling with NC-Box – energy a swimming pool. This means cooling and
efficient and affordable heating functions can be combined extremely
All the components are prefitted in the effectively.
Viessmann NC-Box. This makes the thermally
insulated box not only compact, but also
particularly simple and quick to install.

The NC-Box is equipped with a mixer for


integration in the cooling circuit. This enables
continuous operation without temperatures
falling below the dew point.

For specification, see page 59


Air source
heat pumps
34/35

VITOCAL 200-S
VITOCAL 222-S
Split heat pumps are characterised by their separation into an indoor unit and an
outdoor unit.

As systems for heating only, or as systems Fully equipped indoor units


that provide heating and cooling, these units The indoor units incorporate hydraulic
are ideal for new build and modernisation. components, the heat exchanger (condenser),
They are characterised by separation into a the DHW cylinder (Vitocal 222-S), a high
quiet indoor unit and an air handling outdoor efficiency pump, an instantaneous heating
unit. This design does not require costly wall water heater, a 3-way diverter valve and the
outlets or the routing of air ducts. Vitotronic 200 control unit.

As with other heating systems, the actual Convenient Vitotronic control unit
heat generator is installed inside the building. The Vitotronic 200 control unit, with user
With a maximum width of 600 mm (just prompts, is structured logically and is easy
450 mm in the case of the Vitocal 200-S), to follow. The large backlit display offers
the indoor units can be sited in a basement good contrast, making it easy to read. A help
or even close to the living space in a utility function informs users of the next steps
room, or wall mounted (Vitocal 200-S). to perform. The graphic user interface also The Vitocal 200-S/222-S are
certified in accordance with the
displays heating and cooling curves.
EHPA Quality Label for heat pumps
A high proportion of prefitted components
and the Heat Pump KEYMARK.
makes these compact heating centres easy Efficient and economical
for heating contractors to install, which Split heat pumps operate with astonishing
reduces installation costs. efficiency in partial load operation. The
inverter technology accurately matches
the compressor output to the current heat
demand through modulation, resulting in
high efficiency at every operating point.

Take advantage of these benefits

„ The inverter compressor enables optimum output matching to the heat and cooling demands
„ Convenient reversible design that enables heating and cooling
„ High efficiency in partial load operation through output-controlled compressor
„ Low sound power level of the outdoor unit in partial load operation through variable speed fan
and compressor
„ No frost protection needed for the connection lines as there is no risk of the refrigerant-filled
lines freezing
„ Easy to use Vitotronic 200 control unit with plain text and graphic display
„ Control of Viessmann ventilation units possible
„ Easy and affordable installation without costly wall outlets
„ Prepared for the use of power generated on site, for example by photovoltaic systems
„ Web-enabled via free ViCare app and Vitoconnect (optional)
Air source VITOCAL 200-S
heat pumps 2.3 to 12.0 kW

1
2
7 10
3

4
11

9
5
8

Vitocal 200-S indoor unit Vitocal 200-S outdoor unit


1 Flow switch 7 Coated evaporator with corrugated fins for higher efficiency

2 Instantaneous heating water heater 8 Power saving, variable speed DC fan

(not for type AWB/AWB-M) 9 Variable speed scroll compressor

3 Condenser 10 4-way diverter valve

4 3-way diverter valve for 11 Electronic expansion valve (EEV)

central heating/DHW heating


5 Secondary pump (high efficiency circulation pump)

6 Vitotronic 200 control unit


36/37

The Vitocal 200-S split air source heat pump


utilises the latent heat in the outdoor air for
environmentally responsible and cost effective
heating. It is available either solely for heating
or for heating and cooling.

Extremely quiet outdoor units from


Viessmann
These outdoor units in their timeless design
are very easy on the eye. These appliances
with one or two fans are designed and
manufactured in-house. In addition to
extremely quiet operation, they offer very
good performance data, an excellent finish and
superb product quality – Made in Germany.

Exceptionally quiet outdoor unit


The result is barely audible. In conjunction
with intelligent speed control, the high Very quiet operation, ideal for use in
terraced housing
grade, sound-optimised fans significantly
contribute to reducing airborne noise in full
and partial load operation. Low frequencies Double bearings prevent structure-borne Our recommendation
that are generally perceived as a nuisance in noise
conventional heat pumps are prevented. Double, flexible anti-vibration mounts and Hybrid solutions
acoustically optimised arrangement of the The Vitocal 250-S split
Particularly quiet at night refrigerant circuit components effectively air source heat pump
In night mode, the sound power levels of prevents the emission of structure-borne supplements existing
the fan and compressor are further reduced. sound via the casing and the refrigerant floorstanding or wall
This feature is important in places where line. This means it is nearly impossible for mounted oil or gas
statutory requirements on acoustic emissions vibrations from the outdoor unit to travel to condensing boilers up to
(TA-Lärm: 35 dB(A)) must be observed. This the building structure or into the building. 30 kW.
applies particularly in areas that are densely
developed, such as terraced housing estates. Higher efficiency –
COP: up to 5.0 at A7/W35
Several essential components contribute
to the increase in efficiency. These include
the variable speed scroll compressor, an
asymmetrical plate heat exchanger and the
air evaporator with corrugated fins.

This brochure provides


detailed information on
Take advantage of these benefits hybrid solutions.

„ Low operating costs thanks to high coefficient of performance (COP)


to EN 14511: up to 5.0 (A7/W35) and 4.1 (A2/W35)
„ Especially quiet thanks to advanced acoustic design (AAD), ideal for use
in terraced housing
„ High product quality and a modern, timeless design – Made in Germany
„ Maximum flow temperature up to 60 °C at –10 °C outside temperature
„ Indoor unit with high efficiency circulation pump, condenser, 3-way diverter valve and control unit;
for heating/cooling version with instantaneous heating water heater
„ Heating and cooling with a single appliance thanks to reversible circuit

For specification, see page 60


Air source VITOCAL 222-S
heat pumps 2.3 to 12.0 kW

2
3

5
4
6

Indoor units

7 1 Instantaneous heating water heater


2 Condenser
3 3-way diverter valve for central
heating/DHW heating
4 Flow switch
5 Secondary pump
(high efficiency circulation pump)
6 Vitotronic 200 control unit
7 Enamelled DHW cylinder
(220 litre capacity)
38/39

High DHW convenience


The Vitocal 222-S compact heat pump offers
a high level of DHW convenience thanks to its
220 litre enamelled DHW cylinder, which is
heated via an internal indirect coil.

With their timeless design and a width of just


60 cm, these indoor units can be sited close
to the living space (e.g. in the utility room).
They incorporate hydraulic components, the
heat exchanger (condenser), the DHW
cylinder, a high efficiency pump, an
instantaneous heating water heater, a 3-way
diverter valve and the Vitotronic 200 control
unit.

Heat pump control unit with user prompts


The Vitotronic 200 is structured logically and
is easy to follow. The large backlit display
offers good contrast, making it easy to read.
The graphic user interface also displays
heating and cooling curves. If a solar thermal
system is connected to the Vitocal 242-S, the
solar yield is shown as well.
Vitocal 222-S indoor unit (left) with
the outdoor units
Efficient and economical
Split heat pumps operate with astonishing
efficiency in partial load operation. The
inverter technology accurately matches
the compressor output to the current heat
demand through modulation, resulting in high
efficiency at every operating point.

Vitotronic 200 control unit display

Take advantage of these benefits

„ Attractively priced split air source heat pump


„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511: up to 5.0
(A7/W35) and 4.1 (A2/W35)
„ High level of DHW convenience through integral DHW cylinder with 220 litre capacity
„ Maximum flow temperature: up to 60 °C
„ Convenient reversible design that enables heating and cooling
„ Output control and DC inverter for high efficiency in partial load operation
„ Indoor unit with high efficiency circulation pump, condenser, heat exchanger, 3-way diverter valve,
safety assembly, DHW cylinder and control unit
„ Easy to operate Vitotronic control unit with plain text and graphic display
„ Optimised utilisation of power generated on site by photovoltaic systems
„ Especially quiet operation thanks to advanced acoustic design (AAD)
„ Web-enabled through Vitoconnect (accessories) for operation and service via Viessmann apps

For specification, see page 61


Air source
heat pumps
40/41

VITOCAL 350-A
VITOCAL 300-A/200-A/222-A
Air source heat pumps utilise free energy from the ambient air for heating.
This makes them suitable for both new build and modernisation.

The Vitocal 350-A air source heat pump is Space saving outdoor installation
particularly suitable for modernisation; the Depending on the version chosen, the heat
Vitocal 300-A for modernisation and new pumps can be installed indoors or outdoors.
build; and the Vitocal 200-A/222-A for new Outdoor installation is a particularly space
build. efficient solution. Only the control unit and
hydraulic components are mounted on the
Compared to a brine/water system, an wall inside the house.
investment in an air source heat pump is The Vitocal 350-A, Vitocal 300-A
and Vitocal 200-A/222-A are certified
lower, as the costs for installing a geothermal Viessmann offers everything
in accordance with the EHPA Quality
collector or drilling holes for geothermal from a single source Label for heat pumps.
probes are not incurred. When it comes to transporting heat into
your home, you can rely on Viessmann's
system competence. All pipework required
for connecting the heat pump, as well as the
entire range of accessories, are provided from
a single source, and are perfectly matched to
one another.

Take advantage of these benefits

„ Low operating noise through generously sized air ducts, sound-optimised appliance design and
night mode with reduced fan speed
„ Easy to operate Vitotronic control unit with plain text and graphic display
„ Control of Viessmann ventilation units possible
„ Installation indoors or outdoors with matching accessories
„ Efficient defrosting through circuit reversal
„ Prepared for the use of power generated on site, for example by photovoltaic systems
„ Web-enabled via free ViCare app and Vitoconnect (optional)
Air source VITOCAL 350-A
heat pumps 10.6 to 18.5 kW

2 4 2

Vitocal 350-A
5
1 Intake side
2 Discharge side
6 3 Evaporator
7 4 Radial fan
5 Electronic expansion valve
6 Heat exchanger for enhanced
vapour injection
7 Hermetically sealed Compliant
scroll compressor with enhanced
vapour injection (EVI)
42/43

Ideal for modernisation Vitocal 350-A for indoor installation

The Vitocal 350-A air source heat pump


with rated heating output levels from
10.6 to 18.5 kW is particularly suitable for
modernisation. Thanks to enhanced vapour
injection in the compression process
(EVI cycle), flow temperatures as high as
65 °C can be achieved – even at wintry
outside temperatures. This means the Vitocal
350-A is also suitable for installation in older
heating systems with radiators. To raise
efficiency, we recommend replacing individual
radiators with ultra-low temperature ones.

The Vitotronic 200 heat pump control unit has


an integral cascade function for up to five air
source heat pumps. Heating output levels of
up to 92.5 kW are therefore possible to cover
higher heat demands.

High DHW convenience the Vitocal 350-A all year round. It delivers a
Subject to system version, a higher flow high COP of up to 3.6 (to EN 14511 at A2/
temperature enables a water temperature W35). This results in high annual coefficients
of up to 55 °C inside the DHW cylinder. of performance and very low operating costs.
This allows the Vitocal 350-A to deliver a
particularly high level of DHW convenience. Space saving installation
The Vitocal 350-A achieves its high flow The Vitocal 350-A can be installed either
temperature of 65 °C even at outside indoors or outdoors. The three-stage radial
temperatures as low as – 10 °C. fan in the heat pump, as well as the flow-
optimised air routing and the sound insulated
RCD system for particularly high efficiency casing together make the Vitocal 350-A
The electronic expansion valve and RCD extremely quiet. During night operation the
(refrigerant cycle diagnostic) system also multi stage fan control unit reduces the fan
ensure an extremely high level of efficiency for speed, and thus noise emissions, even further.

Take advantage of these benefits

„ Air source heat pump, mono mode with heating output from 10.6 to 18.5 kW for DHW and
central heating
„ Flow temperature: up to 65 °C
„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511 of up to 3.6
(A2/W35)
„ Matched product accessories for quick and easy hydraulic connection
„ Efficient defrosting through circuit reversal
„ With integral energy statement

For specification, see page 62


Air source VITOCAL 300-A
heat pumps 5.8 to 13.4 kW

Vitocal 300-A

5 6
1 Coated evaporator
2 Sheath current air routing
3 Variable speed EC fan
4 Flow optimisation
5 Variable speed scroll compressor
7 6 Condenser
7 Hydraulic connections
44/45

The Vitocal 300-A air source heat pump stands Wireless or app operation
out not only on account of its contemporary The Vitocal 300-A is equipped with the
design. With a maximum flow temperature of Vitotronic 200 control unit (type WO1C). It is
65 °C for central heating and convenient DHW preset for wireless remote operation and
heating, this appliance is particularly suitable for allows convenient control from the living
modernising detached and two-family houses. space. In conjunction with the ViCare app and
Vitoconnect, the system can also be
Flexible and quiet controlled from anywhere via a smartphone or
The Vitocal 300-A air source heat pump is tablet.
installed outside the building and utilises
free ambient air. Thanks to its variable speed Prepared for operation with photovoltaic
DC fan, modulating compressor and sound- power and Smart Grid
optimised design with sheath current air Connecting to a photovoltaic system enables
routing, the heat pump is exceptionally quiet, further savings on operating costs. The power
with a sound power level below 54 dB(A). generated on site can, for example, be used
The fan speed can also be reduced at night. to run the Vitocal 300-A. The Vitocal 300-A Energy efficiency label
Vitocal 300-A, AWO-AC 301.B14
is also prepared for Smart Grid applications
High COP for reliable heat supply (intelligent integration of consumers in power
The variable speed scroll compressor with grids).
brushless permanent magnet motor and
vapour injection, as well as the electronic
bi-flow expansion valve, contribute to the
high COP to EN 14511 of up to 5.0 (A7/W35).

Vapour injection improves efficiency,


The Vitocal 300-A meets the
particularly at high flow temperatures. The
requirements of the
Vitocal 300-A provides a reliable heat supply EHPA Quality Label.
and considerably reduces electricity costs,
most notably in partial load operation.

Easy cooling in summer


The Vitocal 300-A is capable of reversible
operation to provide cooling during the
warmer months. When high temperatures
occur in summer, convectors or surface
cooling systems make the interior feel
comfortably cool.
The Vitocal 300-A air source heat
pump received the German Design
Award SPECIAL MENTION 2015
in the "Excellent Product Design –
Building and Energy" category.

Take advantage of these benefits

„ Reversible air source heat pump for heating and cooling, for outdoor installation
„ Rated heating output: 5.8 and 13.4 kW at A2/W35
„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511: up to 5.0 at
A7/W35 and 4.0 at A2/W35
„ Flow temperature: up to 65 °C at –5 °C outside temperature
„ Low operating noise thanks to sound-optimised DC fan, reduced fan speed in night mode and
sound-optimised appliance design
„ Optional control and monitoring with wireless remote control units or ViCare app
„ Prepared for Smart Grid and optimised utilisation of power generated on site

For specification, see page 63


Air source VITOCAL 200-A
heat pumps 2.6 to 12.4 kW

2
3

Vitocal 200-A
9
1 Evaporator
4 2 Vitotronic 200 control unit
10
(type WO1C)
5
3 Variable speed radial DC fan
4 Condenser
7
8 5 Filter dryer
6 6 Instantaneous heating water heater
7 High efficiency pump
8 Compressor with output-dependent control
9 Electronic expansion valve
10 3-way diverter valve
46/47

The Vitocal 200-A air source heat pump was


designed in particular with newly built, energy
4
efficient detached houses in mind. It achieves
flow temperatures of 60 °C, but on hot
B 8
summer days it can also be run in reverse for
E
cooling the interior.

Controlling the heat pump using the ViCare


5
app and Vitoconnect online from anywhere is
especially convenient. 6
2 1 3

Economical thanks to inverter technology


The heat pump operates particularly
economically in partial load operation. To
this end, the appliance makes full use of the
benefits offered by its inverter-controlled
compressor. With variable speed control, 7
it matches the heat pump output to the
actual heat demand of the building, whilst Power generated by the PV system (4) is transformed by the System components
inverter (5) from DC into AC power to drive the heat pump
simultaneously saving on power. The variable
(1) and ventilation tower (2). Surplus power is stored in the 1 Vitocal 200-A
speed high efficiency pump and DC fan
battery block (7). 2 Vitovent 300-F
further contribute to its economical operation.
3 Vitocell DHW cylinder
4 Vitovolt 200
Heating and cooling – with electricity
photovoltaic module
from a photovoltaic system if installed
5 Inverter
This is particularly cost effective with air change rate of up to 280 cubic metres per
6 Home Manager
electricity generated on site by a photovoltaic hour. Virtually no valuable heat is lost this way.
7 Vitocharge
system. On summer days, the solar modules
power storage system
generate large amounts of electricity, which The Vitovent 300-F recovers up to 98 percent
8 Heating circuit
frequently cannot be used in the house and of the heat from the extract air and returns it
have to be exported to the grid at a low feed- to the interior. Matching in terms of design Power connection
in tariff. With the Vitocal 200-A, this surplus and colour, the Vitovent 300-F and the E = Export meter
solar power can be used on site to run the Vitocal 200-A heat pump form one single B = Electricity meter
circulation pumps to cool the building. compact unit. Domestic power circuit
Public grid
Mechanical ventilation – Installation and operation
the ideal accompaniment The monoblock design of the Vitocal 200-A
The Vitovent 300-F mechanical ventilation makes for quick and easy installation. It can
system is a perfect addition to the be installed and operated near the living
Vitocal 200-A heat pump. It achieves an space, as it runs very quietly.

Take advantage of these benefits

„ Reversible air source heat pump for heating and cooling, for indoor installation
„ Rated heating output: 2.6 and 12.4 kW at A2/W35
„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511: 3.8 (A2/W35)
„ Flow temperature: up to 60 °C at 5 °C air intake temperature
„ Easy to use, integral Vitotronic 200 (type WO1C) control unit;
can be controlled using the Vitotrol app
„ Control of a Vitovent 300-F mechanical ventilation unit
„ Optimised utilisation of power generated on site by photovoltaic systems

For specification, see page 63


Air source VITOCAL 200-A
heat pumps 2.3 to 12.0 kW

6 11
1
10

2
8

5 9
3 7

Vitocal 200-A indoor unit Outdoor unit


1 Instantaneous heating water heater 6 Coated evaporator with corrugated fins for higher efficiency

2 3-way diverter valve for 7 Power saving, variable speed DC fan

central heating/DHW heating 8 Electronic expansion valve (EEV)

3 Secondary pump (high efficiency circulation pump) 9 Variable speed scroll compressor

4 Vitotronic 200 control unit 10 4-way diverter valve

5 Flow switch 11 Condenser


48/49

Air source heat pumps with a monoblock design are characterised by separation into an
indoor unit and an outdoor unit, with water-carrying connection lines.

The Vitocal 200-S monoblock heat pump Quick installation; certificate of


utilises the latent heat in the outdoor air for competence not required
environmentally responsible and cost effective The compact, wall mounted indoor unit,
heating. It is available either solely for heating complete with hydraulics and control unit,
or for heating and cooling. is quiet and can be installed near the living
space. The lines running to the outdoor
Compact monoblock outdoor units unit can be filled with water. This requires
These outdoor units in their timeless design no certificate of competence (refrigerant The Vitocal 200-A meets
the requirements of the
are very easy on the eye. These appliances certificate) for the installer. The high degree of
EHPA Quality Label.
with one or two fans are designed and pre-assembled components and coordinated
manufactured in-house. Consequently, accessories means the Vitocal 200-A can be
they offer very good performance data, an installed very quickly.
excellent finish and superb product quality –
Made in Germany. Dual mode operation with an existing
system
Especially quiet outdoor unit for this range When it comes to modernisation, the
The acoustic properties of the outdoor heat pump is ideally suited to dual mode
units for the Vitocal monoblock heat pumps operation. In this case the existing system
comply with advanced acoustic design (AAD) remains operational to cover peak loads The Vitocal 200-A is KEYMARK
certified.
specifications. This involves optimising the when temperatures are particularly low. This
frequency spectrum so that low sounds are significantly improves system efficiency.
shifted into a higher frequency range. There,
they are perceived as less of a nuisance Vitotronic 200 with WLAN option
and can be better absorbed by the building The heat pumps can even be controlled from
substance. anywhere using the Vitotronic 200 control unit
via the Vitoconnect web interface (accessory)
The Vitocal 200-A is particularly well suited and the free ViCare app. In addition, they can
to densely built-up areas, such as terraced be combined with Vitovent central mechanical
housing. ventilation units.

Take advantage of these benefits

„ Low operating costs thanks to high coefficient of performance (COP)


to EN 14511: up to 5.0 (A7/W35) and 4.1 (A2/W35)
„ Heating and cooling with a single appliance thanks to reversible circuit
„ Especially quiet thanks to advanced acoustic design (AAD), ideal for use
in terraced housing
„ High product quality and a modern, timeless design – Made in Germany
„ Maximum flow temperature up to 60 °C
„ Monoblock indoor unit with high efficiency circulation pump, 3-way diverter valve and control unit;
the heating/cooling version also has an instantaneous heating water heater

For specification, see page 64


Air source VITOCAL 222-A
heat pumps 2.3 to 12.0 kW

3
5

Vitocal 222-A indoor unit

6
1 Instantaneous heating water heater
2 3-way diverter valve
for central heating/DHW heating
3 Flow switch
4 Secondary pump
(high efficiency circulation pump)
5 Vitotronic 200 control unit
6 Enamelled DHW cylinder
(220 litre capacity)
50/51

Air source heat pumps with a monoblock design are characterised by


separation into an indoor unit and an outdoor unit, with water-carrying
connection lines.

The Vitocal 222-A monoblock heat pump Quick installation; certificate of


utilises the latent heat in the outdoor air for competence not required
environmentally responsible and cost effective The compact, wall mounted indoor unit,
heating. It can provide heating and cooling. complete with hydraulics and control unit,
This compact appliance also includes an is quiet and can be installed near the living
integral 220 litre DHW cylinder. space. The lines running to the outdoor unit
are filled with water, so the installer does not Display of the Vitotronic 200
heat pump control unit
Innovative advanced acoustic design require a special certificate of competence
The acoustic properties of the outdoor units (refrigerant certificate). The high degree of
for the Vitocal 222-A comply with advanced pre-assembled components and coordinated
acoustic design (AAD) specifications. The accessories means the Vitocal 222-A can be
result is barely audible. In conjunction with installed very quickly.
intelligent speed control, the high grade,
sound-optimised fan significantly contributes to High DHW convenience
reducing airborne noise in full and partial load The Vitocal 222-A includes a large, integral
operation. Low frequencies that are generally 220 litre DHW cylinder. The newly developed
perceived as a nuisance in conventional heat inlet system ensures very good stratification,
pumps are largely prevented. which allows a high draw-off volume of up to
290 litres (at 40 °C).
Particularly quiet
With a sound pressure level of only Vitotronic 200 with WLAN option
35 dB(A) at a distance of three metres (night The heat pump can even be controlled
mode), the outdoor unit (with a fan) of the remotely with the Vitotronic 200 control
new Vitocal 222-A compact air source heat unit via the Vitoconnect internet interface
pump is one of the quietest units of its kind. (accessory) and the free ViCare app. In
Installation close to a neighbouring property addition, it can be combined with Vitovent
or in densely built-up areas, such as terraced central mechanical ventilation units.
housing estates, is therefore no problem.

Take advantage of these benefits

„ Low operating costs thanks to high coefficient of performance (COP) to EN 14511:


up to 5.0 (A7/W35) and 4.1 (A2/W35)
„ Heating and cooling with a single appliance thanks to reversible circuit
„ High DHW convenience thanks to 220 l DHW cylinder
„ Especially quiet, thanks to advanced acoustic design (AAD), ideal for use in rows of
terraced houses
„ High product quality and a modern, timeless design – Made in Germany
„ Maximum flow temperature up to 60 °C at – 10 °C outside temperature
„ Monoblock indoor unit with high efficiency circulation pump, 3-way diverter valve, safety
assembly, control unit and integral instantaneous heating water heater

For specification, see page 65


DHW
heat pumps

1 2 1 2

3 3

6 6
5 Vitocal 262-A
5
1 Highly efficient compressor
7 7 2 Large area evaporator for an
efficient heat exchange
3 Control unit
4 Indirect coil (hybrid version)
5 Magnesium anode
6 Dry immersion heater
(accessory for the hybrid version)
7 300 litre DHW cylinder with
Ceraprotect enamel coating

Type T2E Type T2H


52/53

VITOCAL 262-A
DHW heat pump for efficient DHW heating

The Vitocal 262-A DHW heat pump heats Available for recirculation air or outdoor air
domestic hot water affordably and efficiently, The recirculation air version, Vitocal 262-A,
independently of any other central heating utilises air straight from the room where it is
system, by utilising indoor or outdoor air. The installed. Part of the heat from the air that is
heat pump is equally suitable for detached drawn in is extracted and raised to a useful
houses or small commercial enterprises. temperature level (up to 65 °C for improved
Typical applications include bakeries or server DHW hygiene). This removes moisture
rooms, where above average amounts of heat from the rooms, thus protecting the fabric Vitocrossal 300 gas condensing
boiler (left) with Vitocal 262-A
are produced. of the building and improving the indoor
DHW heat pump (type T2H)
environment.
Hybrid version for combination with
existing boilers In outdoor air operation, the appliance
The heat pump is available without an operates in a temperature range of – 8 to
indirect coil (type T2E) for mono mode + 40 °C and can therefore also be operated in
operation. Alternatively, the hybrid version more extreme climatic zones.
with an integral indirect coil (type T2H)
can be selected. This is recommended for Dry immersion heater
retrofitting and upgrading existing systems. The electric version (type T2E) is equipped at
The intelligent control then always selects the the factory with a dry immersion heater. The
optimum operating mode – heat pump or heat hybrid version with indirect coil (type T2H) can
generator – taking into account energy prices also be retrofitted with an immersion heater.
and primary energy factors. The heat pump This immersion heater is limescale-resistant,
preheats the water and, if necessary, the heat and it is not necessary to drain the cylinder if
generator is used for reheating. This ensures it has to be replaced.
maximum DHW convenience at all times.

Take advantage of these benefits

„ DHW heat pump for outdoor air and recirculation air mode with enamelled DHW cylinder
(300 l cylinder capacity)
„ High level of DHW convenience with perfectly hygienic water at temperatures of up to 70 °C –
type T2E with immersion heater (1.5 kW) or type T2H with heat generator
„ Type T2H: intelligent hybrid control for economically or ecologically optimised operation
„ Low operating costs thanks to highly efficient refrigerant circuit
„ Low noise emissions thanks to special silent mode
„ DHW heated to a maximum temperature of 70 °C (up to 65 °C via heat pump module and up to 70 °C
with immersion heater or heat generator)
„ Quick heat-up function with immersion heater
„ Installation in rooms with low ceilings (up to 2 m)
„ Smart Grid ready (SG ready)
„ Prepared for optimised consumption of power generated on site by photovoltaic systems –
two-stage function possible (heat pump and immersion heater)
„ Dehumidification of basement rooms in existing buildings (recirculation air mode)

For specification, see page 66


Air source VITOCAL 300-A
heat pumps 11.3 to 50.0 kW (two-stage)

1
2

6 Vitocal 300-A
5
4
3 1 Evaporator
2 Fan
3 Compressor stage 2
4 Compressor stage 1
5 Refrigerant receiver
6 Optional pipework assembly
for connection at the side
54/55

VITOCAL 300-A
Vitocal 300-A – the highly efficient air source heat pump up to 50 kW –
up to 250 kW output possible with a five-appliance cascade.

The Vitocal 300-A from Viessmann is an Convenient control


air source heat pump in the output range The Vitotronic 200 (WO1C) is wall mounted
from 11.3 to 50 kW. Output up to 250 kW inside the building for easy access, which
is possible in a cascade of up to five facilitates straightforward commissioning
Vitocal 300-A heat pumps. and control of the heat pump. In a dual mode
system, for example in combination with
Good choice for modernised buildings a gas or oil boiler, the heat pump control
A COP of up to 3.9 enables these heat unit can start the second heat generator
pumps for outdoor installation to meet the automatically.
requirements for convenient heat provision in
the residential rental sector. The Vitocal 300-A The optionally available Vitotrol 200-RF
is also the perfect choice for modernised remote control offers an extra level of
buildings equipped with conventional convenience. It can control the energy system
radiators. Even at outside temperatures as wirelessly from the living space. Furthermore,
low as – 25 °C, this unit still achieves a flow the Vitotrol app and Vitoconnect enable
temperature of 58 °C. wireless control from anywhere using the Energy efficiency label
Vitocal 300-A, AWO 302.A25
internet.
Two compressors for lower operating costs
Two output stages ensure the Vitocal 300-A Where the Vitocal 300-A is used in
operates economically. Experience has commercial applications, it can be linked to a
shown that approximately 70 percent of the building management system using Vitogate
annual heat load can be covered under partial 200 KNX.
load conditions. This means the heat pump
operates with only one compressor, which
achieves the highest COP values.

Vitotronic 200 (WO1C) weather-


compensated control unit for wall
mounting

Take advantage of these benefits

„ Two-stage air source heat pump with high output: 11.3 to 50 kW


„ Cascade of 5 heat pumps for output up to 250 kW
„ Flow temperature: up to 58 °C
„ Low operating costs thanks to high coefficients of performance (COP) to EN 14511 of up to 4.4 at
A7/W35 and up to 3.8 at A2/W35 in two-stage operation
„ Excellent partial load characteristics thanks to two-stage design
„ Low noise and vibration emissions through sound-optimised appliance design
„ Vitotronic 200 (WO1C) wall mounted control unit with plain text and graphic display
„ Integration into the building management system via Vitogate 200 KNX
„ Flexible siting – hydraulic connections at the side or bottom of the casing

For specification, see page 67


Specification Brine/water heat pumps

Vitocal 333-G, Vitocal 333-G NC, Vitocal 343-G


Vitocal 333-G Type BWT 331.B06 BWT 331.B08 BWT 331.B10
Vitocal 333-G NC Type BWT-NC 331.B06 BWT-NC 331.B08 BWT-NC 331.B10
Vitocal 343-G Type BWT 341.B06 BWT 341.B08 BWT 341.B10
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 5.7 7.6 10.4
COP ¡ in heating mode 4.6 4.8 5.0
Maximum flow temperature °C Up to 65 Up to 65 Up to 65
Refrigerant circuit
Refrigerant R410A R410A R410A
– Refrigerant charge kg 1.40 1.95 2.40
– Global warming potential (GWP) 2088 2088 2088
– CO2 equivalent t 2.9 4.1 5.0
Dimensions
Length (depth) x width x height
Vitocal 333-G, Vitocal 333-G NC mm 680 x 600 x 1829
Vitocal 343-G mm 680 x 600 x 2075
Cylinder capacity
Vitocal 333-G litres 170 170 170
Vitocal 343-G litres 220 220 220
NL performance factor
Vitocal 333-G 1.0 1.1 1.3
Vitocal 343-G 1.5 1.5 1.6
Weight
Vitocal 333-G kg 248 249 256
Vitocal 333-G NC kg 253 254 261
Vitocal 343-G kg 258 259 266
Energy efficiency class* A++ / A++ A++ / A++ A+++ / A+++
DHW heating:
Draw-off profile XL XL XL
Energy efficiency class A A+ A+

Vitocal 222-G, Vitocal 242-G


Vitocal 222-G Type BWT 221.A06 BWT 221.A08 BWT 221.A10
Vitocal 242-G Type BWT 241.A06 BWT 241.A08 BWT 241.A10
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 6.1 7.4 10.0
COP ¡ in heating mode 4.5 4.5 4.5
Maximum flow temperature °C Up to 60 Up to 60 Up to 60
Refrigerant circuit
Refrigerant R410A R410A R410A
– Refrigerant charge kg 1.80 1.80 2.05
– Global warming potential (GWP) 2088 2088 2088
– CO2 equivalent t 3.8 3.8 4.3
Dimensions
Length (depth) x width x height
Vitocal 222-G mm 680 x 600 x 1829
Vitocal 242-G mm 680 x 600 x 2075
Cylinder capacity
Vitocal 222-G litres 170 170 170
Vitocal 242-G litres 220 220 220
N L performance factor
Vitocal 222-G 1.0 1.1 1.3
Vitocal 242-G 1.5 1.5 1.6
Weight
Vitocal 222-G kg 250 250 256
Vitocal 242-G kg 260 260 266
Energy efficiency class* A++ / A++ A++ / A++ A++ / A++
DHW heating:
Draw-off profile XL XL XL
Energy efficiency class A A A

* Energy efficiency class as per Regulation (EU) No. 811/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
56/57

Vitocal 300-G (brine/water)


Vitocal 300-G Type BW/BWC/BWS BW/BWC/BWS BW/BWC/BWS BW/BWC/BWS BW/BWC/BWS
Brine/water 301.B06 301.B08 301.B10 301.B13 301.B17
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 5.7 7.6 10.4 13.0 17.2
COP ¡ in heating mode 4.6 4.7 5.0 5.0 4.7
Maximum flow temperature °C 65 65 65 65 65
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.40 1.95 2.40 2.25 2.75
– Global warming potential (GWP) 2088 2088 2088 2088 2088
– CO2 equivalent t 2.9 4.1 5.0 4.7 5.7
Dimensions
Length (depth) mm 845 845 845 845 845
Width mm 600 600 600 600 600
Height (programming unit open) mm 1049 1049 1049 1049 1049
Weight
Type BW kg 113 117 129 135 148
Type BWC kg 123 127 139 145 158
Type BWS kg 109 113 125 131 144
Energy efficiency class* A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++

Master/slave pack each with the Type BW/BWS BW/BWS BW/BWS BW/BWS BW/BWS
same rated heating output 301.B06 301.B08 301.B10 301.B13 301.B17
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 11.4 15.2 20.8 26.0 34.4

Vitocal 300-G (water/water)


Vitocal 300-G Type BW/BWC/BWS BW/BWC/BWS BW/BWC/BWS BW/BWC/BWS BW/BWC/BWS
Water/water 301.B06 301.B08 301.B10 301.B13 301.B17
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 7.5 10.2 13.5 16.9 22.6
COP ¡ in heating mode 6.1 6.6 6.6 6.5 6.2
Maximum flow temperature °C 65 65 65 65 65

Vitocal 200-G
Vitocal 200-G Type BWC 201.A06 BWC 201.A08 BWC 201.A10 BWC 201.A13 BWC 201.A17
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 5.6 7.6 9.7 13.0 17.2
COP ¡ in heating mode 4.4 4.4 4.4 4.5 4.5
Maximum flow temperature °C 60 60 60 60 60
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.20 1.45 1.70 2.20 2.90
– Global warming potential (GWP) 2088 2088 2088 2088 2088
– CO2 equivalent t 2.5 3.0 3.6 4.6 6.1
Dimensions
Length (depth) mm 845 845 845 845 845
Width mm 600 600 600 600 600
Height (control unit open) mm 1049 1049 1049 1049 1049
Weight kg 113 117 129 135 148
Energy efficiency class* A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++

* Energy efficiency class as per Regulation (EU) No. 811/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Specification Brine/water heat pumps

Vitocal 350-G (brine/water)


Vitocal 350-G (single stage, master) Type BW 351.B20 BW 351.B27 BW 351.B33 BW 351.B42
Vitocal 350-G (2-stage, slave without own control unit) Type BWS 351.B20 BWS 351.B27 BWS 351.B33 BWS 351.B42
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 20.5 28.7 32.7 42.3
COP ¡ in heating mode 4.8 4.9 5.0 4.8
Maximum flow temperature (5 K/12 K spread) °C 65/70 65/70 65/70 65/70
Refrigerant circuit
Refrigerant R410A R410A R410A R410A
– Refrigerant charge kg 5.5 7.3 9.0 9.25
– Global warming potential (GWP) 2088 2088 2088 2088
– CO2 equivalent t 11.5 15.2 18.8 19.3
Dimensions
Length (depth) mm 1085 1085 1085 1085
Width mm 780 780 780 780
Height (with control unit open) mm 1267 1267 1267 1267
Weight
Type BW kg 270 285 310 315
Type BWS kg 265 280 305 310
Energy efficiency class* A++ / A++ A++ / A++ A++ / A++ A++ / A++

Vitocal 350-G (water/water)


Vitocal 350-G (single stage, master) Type BW 351.B20 BW 351.B27 BW 351.B33 BW 351.B42
Vitocal 350-G (2-stage, slave without own control unit) Type BWS 351.B20 BWS 351.B27 BWS 351.B33 BWS 351.B42
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 25.4 34.7 42.2 52.3
COP ¡ in heating mode 5.7 6.1 6.2 5.8
Maximum flow temperature (5 K/12 K spread) °C 65/70 65/70 65/70 65/70

Vitocal 300-G (brine/water)


Vitocal 300-G Type BW 301.A21 BW 301.A29 BW 301.A45
Vitocal 300-G Type BWS 301.A21 BWS 301.A29 BWS 301.A45
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 21.2 28.8 42.8
COP ¡ in heating mode 4.7 4.8 4.6
Maximum flow temperature °C 60 60 60
Refrigerant circuit
Refrigerant R410A R410A R410A
– Refrigerant charge kg 4.7 6.2 7.7
– Global warming potential (GWP) 2088 2088 2088
– CO 2 equivalent t 11.5 13.0 16.1
Dimensions
Length (depth) mm 1085 1085 1085
Width mm 780 780 780
Height mm 1267 1267 1267
Weight
Type BW kg 245 272 298
Type BWS kg 240 267 293
Energy efficiency class* A++ / A++ A++ / A++ A++ / A++

Vitocal 300-G (water/water)


Vitocal 300-G Type BW 301.A21 BW 301.A29 BW 301.A45
Vitocal 300-G Type BWS 301.A21 BWS 301.A29 BWS 301.A45
Performance data
(to EN 14511, B0/W35 °C, 5 K spread)
Rated heating output kW 28.1 37.1 58.9
COP ¡ in heating mode 5.9 6.0 5.5
Maximum flow temperature °C 60 60 60

* Energy efficiency class as per Regulation (EU) No. 811/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
58/59

Natural cooling NC-Box

Performance data
Cooling capacity subject to the heat pump output
for Vitocal 343-G/333-G/300-G/242-G/222-G/200-G kW Approx. 1.25 – 5.0

Dimensions
Length (depth) mm 520
Width mm 580
Height mm 420

Weight incl. mixer kg 28

Active cooling AC-Box

The maximum cooling capacity is limited by the integral heat pump


(for Vitocal 300-G, type BWC/BW 301.B06-17)

Dimensions
Length (depth) mm 717
Width mm 350
Height mm 973

Weight kg 80
Specification Split air source heat pumps

Vitocal 200-S

Vitocal 200-S Type AWB-M/AWB-M-E-AC AWB/AWB-E-AC

201.D04 201.D06 201.D8 201.D010 201.D10 201.D13 201.D16

Voltage V 230 230 230 230 400 400 400

Performance data – heating


(to EN 14511, A2/W35)
Rated heating output kW 2.6 3.1 4.0 5.0 5.9 6.3 7.0
COP ¡ in heating mode 3.6 3.7 4.0 4.0 4.1 4.0 3.9
Output control kW 2.0 – 4.1 2.4 – 5.5 2.8 – 7.0 4.4 – 9.6 4.4 – 10.1 4.8 – 10.6 5.2 – 11.2

Performance data – heating


(to EN 14511, A7/W35, 5 K spread) kW 4.0 4.8 5.6 7.0 7.6 8.6 10.1
COP ¡ in heating mode 4.6 4.6 4.7 4.7 5.0 4.9 5.0
Output control kW 3.2 – 5.7 3.8 – 6.6 4.6 – 8.5 5.5 – 12.6 5.5 – 13.6 5.9 – 14.2 6.4 – 14.7

Performance data – heating


(to EN 14511, A–7/W35, 5 K spread) kW 3.8 5.5 6.7 8.7 10.1 10.7 11.6
COP ¡ in heating mode 2.9 2.8 2.9 3.1 3.2 3.0 3.0

Performance data – cooling


(to EN 14511, A35/W18)
Rated cooling capacity kW 4.0 5.0 6.0 7.0 7.0 8.2 9.2
EER in cooling mode 4.2 4.2 4.1 4.1 4.0 3.9 3.8

Dimensions, outdoor unit


Length (depth) mm 546 546 546 546 546 546 546
Width mm 1109 1109 1109 1109 1109 1109 1109
Height mm 753 753 753 1377 1377 1377 1377

Dimensions, indoor unit


Length (depth) x width x height mm 370 x 450 x 880

Weight
Outdoor unit kg 94 94 99 137 148 148 148
Indoor unit type AWO-M-E-AC, AWO-E-AC kg 44 44 44 45 45 45 45

Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.8 1.8 < 2.4 3.6 3.6 3.6 3.6
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO 2 equivalent t 3.8 3.8 < 5.0 7.5 7.5 7.5 7.5

Energy efficiency class* A++ / A+ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
60/61

Vitocal 222-S

Vitocal 222-S Type AWBT-M-E / AWBT-M-E-AC AWBT-E / AWBT-E-AC

221.C04 221.C06 221.C08 221.C10 221.C10 221.C13 221.C13

Voltage V 230 230 230 230 400 400 400

Performance data – heating


(to EN 14511, A2/W35)
Rated heating output kW 2.6 3.1 4.0 5.0 5.9 6.3 7.0
COP ¡ in heating mode 3.6 3.7 4.0 4.0 4.1 4.0 3.9
Output control kW 2.0 – 4.1 2.4 – 5.5 2.8 – 7.0 4.4 – 9.6 4.4 – 10.1 4.8 – 10.6 5.2 – 11.2

Performance data – heating


(to EN 14511, A–7/W35)
Rated heating output kW 3.8 5.5 6.7 8.7 10.1 10.7 11.6
COP ¡ in heating mode 2.9 2.8 2.9 3.1 3.2 3.0 3.0

Performance data – cooling


(to EN 14511, A35/W18)
Rated cooling capacity kW 4.0 5.0 6.0 7.0 7.0 8.2 9.2
EER in cooling mode 4.2 4.2 4.1 4.1 4.0 3.9 3.8

Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.8 1.8 2.39 3.6 3.6 3.6 3.6
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO2 equivalent t 3.8 3.8 < 5.0 7.5 7.5 7.5 7.5

Cylinder capacity litres 220 220 220 220 220 220 220

Dimensions, indoor unit


Length (depth) x width x height mm 681 x 600 x 1874

Dimensions, outdoor unit


Length (depth) mm 546 546 546 546 546 546 546
Width mm 1109 1109 1109 1109 1109 1109 1109
Height mm 753 753 753 1377 1377 1377 1377

Weight
Indoor unit kg 169 169 169 170 170 170 170
Outdoor unit kg 94 94 99 137 148 148 148

Energy efficiency class* A++ / A+ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++

Draw-off profile L L L L L L L
Efficiency class A A A A A A A

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Specification Air source heat pumps

Vitocal 350-A

Vitocal 350-A (outdoor installation) Type AWHO 351.A10 AWHO 351.A14 AWHO 351.A20
Vitocal 350-A (indoor installation) Type AWHI 351.A10 AWHI 351.A14 AWHI 351.A20

Performance data (to EN 14511, A2/W35 °C)


Rated heating output kW 10.6 14.5 18.5
Power consumption kW 2.9 4.2 5.8
COP ¡ in heating mode 3.6 3.5 3.2
Maximum flow temperature °C Up to 65 Up to 65 Up to 65

Refrigerant circuit
Refrigerant R407C R407C R407C
– Refrigerant charge kg 4.0 4.5 5.2
– Global warming potential (GWP) 1774 1774 1774
– CO2 equivalent t 7.1 8.0 9.2

Dimensions, outdoor installation


Length (depth) mm 1265 1265 1265
Width mm 1380 1530 1700
Height mm 1885 1885 1885
Dimensions, indoor installation
Length (depth) mm 946 946 946
Width mm 880 1030 1200
Height mm 1870 1870 1870

Weight, outdoor installation kg 325 335 400


Weight, indoor installation kg 287 297 361

Energy efficiency class* A++ / A+ A+ / A+ A+ / A+

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
62/63

Vitocal 300-A

Vitocal 300-A, type AWO-AC 301.B07 301.B11 301.B14

Performance data
Rated heating output
Operating point A2/W35 (to EN 14511) kW 7.4 7.0 8.5
Operating point A–7/W35 (to EN 14511) kW 7.0 10.5 12.0
Output range min./max. kW 5.8 – 9.7 5.8 – 12.0 7.2 – 13.4
Coefficient of performance ¡ (COP) A2/W35 4.0 3.9 3.9
Coefficient of performance ¡ (COP) A7/W35 5.0 5.0 5.0
Rated cooling capacity
Operating point A35/W18 (to EN 14511) kW 8.1 8.1 9.0

Maximum flow temperature °C Up to 65 Up to 65 Up to 65

Sound power level


Min./max./night mode dB(A) 49/53/51 49/53/51 50/54/52
Operating point A7/W55

Refrigerant circuit
Refrigerant R410A R410A R410A
– Refrigerant charge kg 4.75 4.75 4.75
– Global warming potential (GWP) 2088 2088 2088
– CO2 equivalent t 9.9 9.9 9.9

Total dimensions
Length (depth) x width x height mm 1100 x 1100 x 1980

Weight kg 250 250 250


++/A++
Energy efficiency class* A A++/A++ A++/A++

Vitocal 200-A

Vitocal 200-A Type AWCI-AC 201.A07 AWCI-AC 201.A10

Performance data
Rated heating output
Operating point A2/W35 (to EN 14511) kW 5.0 7.0
Operating point A–7/W35 (to EN 14511) kW 7.5 10.1
Output range min./max. kW 2.6 – 8.3 2.9 – 12.4
Coefficient of performance ¡ (COP) A2/W35 3.8 3.5
Coefficient of performance ¡ (COP) A7/W35 4.8 4.7
Rated cooling capacity
Operating point A35/W18 (to EN 14511) kW 5.3 8.8
Energy efficiency ratio EER 3.2 3.2

Maximum flow temperature °C Up to 60 Up to 60

Refrigerant circuit
Refrigerant R410A R410A
– Refrigerant charge kg 2.2 3.2
– Global warming potential (GWP) 2088 2088
– CO2 equivalent t 4.6 6.7

Dimensions
Length (depth) x width x height mm 800 x 700 x 1850

Weight kg 232 254

Energy efficiency class* A++ / A++ A++ / A++

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Specification Air source heat pumps

Vitocal 200-A (monoblock version)

Vitocal 200-A Type AWO-M/AWO-M-E-AC AWO/AWO-E-AC

201.A04 201.A06 201.A08 201.A010 201.A10 201.A13 201.A16

Voltage V 230 230 230 230 400 400 400

Performance data – heating


(to EN 14511, A2/W35)
Rated heating output kW 2.6 3.1 4.0 5.0 6.1 6.7 7.0
COP ¡ in heating mode 3.6 3.8 4.0 4.0 4.1 4.1 3.9
Output control kW 2.0 – 4.1 2.4 – 5.5 2.8 – 7.0 4.4 – 9.6 4.4 – 10.1 4.8 – 10.6 5.2 – 11.2

Performance data – heating


(to EN 14511 A7/W35, 5 K spread) kW 4.0 4.8 5.6 7.0 7.6 8.9 10.1
COP ¡ in heating mode 4.6 4.7 4.7 4.7 5.0 5.0 5.0
Output control kW 3.2 – 5.7 3.8 – 6.6 4.6 – 8.5 5.5 – 12.6 5.5 – 13.6 5.9 – 14.2 6.4 – 14.7

Performance data – heating


(to EN 14511 A–7/W35, 5 K spread) kW 3.8 5.7 6.7 8.7 10.1 11.0 11.6
COP ¡ in heating mode 2.9 2.9 2.9 3.1 3.2 3.1 3.0

Performance data – cooling


(to EN 14511 A35/W18)
Rated cooling capacity kW 4.0 5.0 6.0 7.0 7.0 8.2 9.2
EER in cooling mode 4.2 4.2 4.1 4.1 4.0 3.9 3.8

Dimensions, outdoor unit


Length (depth) mm 546 546 546 546 546 546 546
Width mm 1109 1109 1109 1109 1109 1109 1109
Height mm 753 753 753 1377 1377 1377 1377

Dimensions, indoor unit


Length (depth) x width x height mm 370 x 450 x 880

Weight
Outdoor unit kg 102 102 103 145 153 153 153
Indoor unit type AWO-M-E-AC, AWO-E-AC kg 41 41 41 41 41 41 41

Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.4 1.4 1.4 2.4 2.4 2.4 2.4
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO2 equivalent t 2.9 2.9 2.9 5.0 5.0 5.0 5.0

Energy efficiency class* A++ / A+ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
64/65

Vitocal 222-A (monoblock version)

Vitocal 222-A Type AWOT-M-E / AWOT-M-E-AC AWOT-E / AWOT-E-AC

221.A04 221.A06 221.A08 221.A10 221.A10 221.A13 221.A16

Voltage V 230 230 230 230 400 400 400

Performance data – heating


(to EN 14511, A2/W35)
Rated heating output kW 2.6 3.1 4.0 5.0 6.1 6.7 7.0
COP ¡ in heating mode 3.6 3.8 4.0 4.0 4.1 4.1 3.9
Output control kW 2.0 – 4.1 2.4 – 5.5 2.8 – 7.0 4.4 – 9.6 4.4 – 10.1 4.8 – 10.6 5.2 – 11.2

Performance data – heating


(to EN 14511, A–7/W35)
Rated heating output kW 3.8 5.7 6.7 8.7 10.1 11.1 11.6
COP ¡ in heating mode 2.9 2.9 2.9 3.1 3.2 3.1 3.0

Performance data – cooling


(to EN 14511, A35/W18)
Rated cooling capacity kW 4.0 5.0 6.0 7.0 7.0 8.2 9.2
EER in cooling mode 4.2 4.2 4.1 4.1 4.0 3.9 3.8

Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.4 1.4 1.4 2.4 2.4 2.4 2.4
– Global warming potential (GWP) 2088 2088 2088 2088 2088 2088 2088
– CO 2 equivalent t 2.9 2.9 2.9 5.0 5.0 5.0 5.0

Cylinder capacity litres 220 220 220 220 220 220 220

Assessed total sound power level at


A7/W55 in night mode dB(A) 50 50 50 55 55 55 55

Dimensions, indoor unit


Length (depth) x width x height mm 681 x 600 x 1874

Dimensions, outdoor unit


Length (depth) mm 546 546 546 546 546 546 546
Width mm 1109 1109 1109 1109 1109 1109 1109
Height mm 753 753 753 1377 1377 1377 1377

Weight
Indoor unit kg 164 164 164 164 164 164 164
Outdoor unit kg 102 102 103 145 153 153 153

Energy efficiency class* A+ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++

Draw-off profile L L L L L L L
Efficiency class A A A A A A A

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
Vitocal 262-A DHW heat pump

Vitocal 262-A Type T2E T2H**

Performance data for recirculation air mode


to EN 16147:2017 at A20/W10-53
(air intake temperature 20 °C/room temperature 20 °C)
Coefficient of performance ¡ (COP) 3.8 3.8
Maximum available amount of water (40 °C) litres 409.2 409.2
DHW heating energy efficiency dwh % 155 155
Annual electricity consumption (AEC) kWh 1081 1081

Performance data for outdoor air mode


to EN 16147:2017 average temperature at A7/W10-53
(air intake temperature 7 °C/room temperature 20 °C)
Coefficient of performance ¡ (COP) 3.3 3.3
Maximum available amount of water (40 °C) litres 393.9 393.9
DHW heating energy efficiency dwh % 134 134
Annual electricity consumption (AEC) kWh 1246 1246

Refrigerant circuit
Refrigerant R134a R134a
– Refrigerant charge kg 1.35 1.35
– Global warming potential (GWP) 1430 1430
– CO2 equivalent t 1.93 1.93

Maximum power consumption


of the immersion heater (accessory for type T2H) kW 1.5 1.5

Cylinder capacity litres 298 291

Weight kg 145 160

Dimensions length (Ø) x width x height mm 765 x 667 x 1848

Energy efficiency class


DHW heating*
Draw-off profile XL XL
Energy efficiency class A+ A+

* Energy efficiency class to Regulation (EU) No. 813/2013 for water heaters
** Details for heat pump operation only
66/67

Vitocal 300-A

Vitocal 300-A Type AWO 302.A25 AWO 302.A40 AWO 302.A60

Performance data
Rated heating output
Operating point A2/W35 (to EN 14511) kW 11.3 – 19.6 16.8 – 29.3 26.4 – 50.0
Operating point A–7/W35 (to EN 14511) kW 9.10 – 16.7 13.5 – 23.8 21.2 – 39.2
COP ¡, two-stage operation
Operating point A2/W35 (to EN 14511) 3.7 3.8 3.6
Operating point A7/W35 (to EN 14511) 4.4 4.4 4.1

Refrigerant circuit
Vitocal 300-A Refrigerant R404A R404A R417A
(AWO 302.A25 and AWO 302.A40) – Refrigerant charge kg 10.2 11.8 20.9
– Global warming potential (GWP) 3922 3922 2346
– CO2 equivalent t 40.0 46.3 49.0

Maximum flow temperature °C Up to 58 Up to 58 Up to 65

Sound power level


Modelled on EN ISO 12102 dB(A) 67 70 74

Total dimensions
Length (depth) mm 955 955 1000
Width mm 1600 1735 1900
Height mm 1940 2100 2300

Weight kg 485 555 871

Energy efficiency class* A++ / A++ A++ / A++ A++ / A++

Vitocal 300-A (AWO 302.A60)

* Energy efficiency class as per Regulation (EU) No. 813/2013 regarding heating under average climate conditions for
low (W35)/ medium temperature applications (W55)
System technology Everything from a single source

System technology ensures reliable and


economical operation
The convenient controls and perfectly matched Viessmann system components offer
maximum reliability, flexibility and efficiency.

"The whole is greater than the sum of its Viessmann system technology incorporates
parts." In accordance with this philosophy, everything you need for a reliable and
Viessmann does not simply supply individual economical heating system.
heating equipment components that meet
the high Viessmann standards for quality, This includes the Vitotronic control unit with
reliability and effectiveness. In addition, wireless remote control and online control
all products are part of a matching overall using the ViCare app, powerful Vitocell DHW
concept, where all components complement cylinders for the highest DHW convenience,
one another. After all, only perfect interaction and high grade photovoltaic systems.
between all system parts can draw out the
maximum potential of our innovative leading
technology.
68/69

Operating convenience
Clear, convenient, intelligent: the Vitotronic
offers perfect functionality for fast and precise
control of any heating system.

Connectivity
With Vitoconnect and a smartphone,
controlling Viessmann heating systems
couldn't be easier. Heating systems can be
controlled with the ViCare app (page 8/9). All
apps are available for mobile devices running
iOS or Android operating systems.

Photovoltaic systems
The sun supplies more power than we need.
This is economical – generating solar power
is already significantly cheaper than drawing
domestic power from the grid.

Mechanical ventilation systems


Controlled mechanical ventilation systems
with heat recovery continuously replace the
air in the living space and remove odours
and noxious substances, for a healthy,
comfortable indoor environment. And they do
so in an extremely energy efficient way.

DHW cylinders
DHW convenience for every demand:
Vitocell DHW cylinders are convenient
solutions for supplying a household with hot
water – the perfect complement to any new
heat pump.
Scan the QR code to
receive further information
about the Vitocell

System accessories
In addition to the high quality Viessmann
products, we also offer system components
from other well known manufacturers with
the Vitoset range of accessories. Radiators,
expansion vessels, pipework, pumps, filters
and valves – Vitoset offers the complete range Scan the QR code to
of accessories for your Viessmann heating discover more about the
system. Viessmann radiator range
System technology Efficient on-site consumption of solar power by a heat pump

Vitocell 100-V (type CVAA)


DHW cylinder, Vitocharge power
There are currently two ways in which the solar
storage system and Vitocal 300-G
power generated by a rooftop photovoltaic
heat pump (from left to right)
system can be used: it can either all be
exported to the grid, or it can be partially or
fully consumed on site. The most efficient way
to generate heat from power is by using a heat
pump. With a heat pump, one kilowatt-hour of
electricity can provide up to four kilowatt-hours
of heat by using free natural energy from the
environment.

By meeting the energy demand for DHW


and central heating with the help of a heat
pump, the user can significantly increase the
proportion of solar power consumed on site,
whilst also enjoying reduced heating bills by
Vitocharge power storage system – thanks to its modular making use of low cost solar power.
design, the usable storage capacity can be adjusted up to a
maximum of 12.8 kWh
70/71

If you intend to combine a PV system with a The economic viability of the photovoltaic
heat pump, select an appliance that optimises system is substantially increased thanks to
on-site consumption and can be adapted to the deliberate increase in the proportion of
match the power generating characteristics of on-site consumption. Using low cost solar
the PV system. For this purpose Viessmann power also makes the heat pump more
has developed a suitably matched system economically attractive.
comprising PV and heat pump.
The Vitocharge power storage system Actual charging and operating
conditions of the Vitocharge can be
Optimised system concept offers independence from the public
viewed on the display.
with Viessmann heat pumps electricity grid
Via an energy meter, the heat pump control The Vitocharge power storage system rounds
unit detects whether the PV system is off the energy system. It enables power to
supplying sufficient amounts of power – be supplied exactly when it is needed. This
which is then used by the heat pump to heat makes efficient, decentralised power supply
DHW and heating water. The heat gained with high levels of on-site consumption and
during the day via photovoltaic technology is self-sufficiency a reality. Viessmann is the
stored in a well-insulated cylinder and can be only manufacturer to supply all products
used for domestic hot water and heating as from a single source, so that users can
and when required. make effective and economical use of the
power they generate. This offers the user
The Vitotronic 200 control unit automatically independence from the public electricity grid.
increases the on-site consumption of solar
power. Combining the Viessmann heat pump The Vitocharge is charged when there is surplus
with a photovoltaic system also offers the power. As soon as more power is needed again,
option of integrating additional components this additional energy is delivered from the
that increase on-site consumption of the battery. When combined with a PV system,
solar power generated, such as ventilation the energy generated during the day can be
equipment, for example. Before the heat pump stored. At night, an electric vehicle can be
is activated, priority is given to meeting charged, for example, so that it is ready to be
the power demand for electrical household driven in the morning.
appliances with the solar power generated
on site. After the demand from household Self-generated power for the heat pump
appliances has been satisfied, an energy Another particularly effective way to save
meter records the amount of solar power energy is by enabling interaction between a
remaining and communicates this to the heat heat pump, PV system and Vitocharge. This
pump. Using the heat pump, the solar surplus involves the electrical components in the heat
can then be stored in the form of thermal pump being operated with power generated
energy and made available when it is required. on site.
This raises the level of on-site consumption
and makes use of the solar energy while it is
available.

Take advantage of these benefits

„ The combination of photovoltaic system and heat pump increases on-site


consumption of low cost solar power and therefore reduces the cost of heating
and cooling
„ The system is suitable for the integration of other renewable energy generators
„ When combined with the Vitofriocal ice store system, for example, heat source
management can be further optimised
Service Viessmann trade partners

With our trade partners, you're in good hands

At Viessmann, proximity to trade partners is the basis of the company's success.


Everyone can benefit from their expertise by choosing a Viessmann heat pump.

Property developers and system users can Every system user benefits from the
receive advice and support regarding sales, comprehensive service that all installation
installation and customer service exclusively contractors offer as standard.
via Viessmann trade partners, who complete
regular training at the Viessmann Academy,
and have an in-depth knowledge of the
company's products.
72/73

Some service examples

„ Free, no-obligation and individual


consultation, even on site
„ Clear calculation of savings on heating
costs following modernisation of your
heating system – including systems
combined with solar collectors, of course
„ Calculation of the payback period, after
which the new heating system will have
paid for itself through energy savings
„ Calculation of the actual heat and DHW
demand for your household or property
„ Information on the most viable
combination of a new heating system with
a solar thermal system for central heating
backup and DHW heating
„ Up to date information about public subsidy
programmes that could help to finance a
new heat pump and a solar thermal system
„ Support in applying for subsidies Reliable and competent advice from Viessmann employees
and trade specialists on site and at their offices

Technology from Viessmann –


subsidies from the public purse
You don't just save on running costs. Energy
savings and environmentally responsible Attractive finance – invest now and save
heating technology is also financially on heating costs immediately
supported by local, regional and national With the Viessmann finance model, you can
bodies through various subsidies, as well as start saving straight away, and turn your plans Terms and conditions to
by local power supply utilities [in Germany]. into reality. The fast and reliable process, with shout about
no red tape, makes modernisation projects If you invest now in a new
Up to date information can be found easier, allowing your financial planning to solar thermal system for
on the internet at www.viessmann.de/ remain flexible. The particular advantage is that your property, you may be
foerderprogramme, or ask your heating with Viessmann's favourable terms, savings on eligible for an attractive
contractor. heating costs are generally significantly higher finance package from
than finance costs. Viessmann in conjunction
with CreditPlus Bank:
Please note just 3.99 percent* effective
Applications for subsidies and finance must APR.
be made before the heating and/or solar
thermal system is purchased. Subsidies and
finance agreements cannot be arranged
* Over 24 months
retrospectively.

New offer for heat pump customers:


special rates from Grundgrüner
GRUND-
Wärmestrom
GRÜNER
Available to every system operator [in
WÄRME-
Germany] under the green and white label at
STROM
www.grundgruener-waermestrom.de, heat
pump customers will find a special electricity
tariff offered for power from renewable
energy sources, specifically tailored to
Viessmann heat pumps.
Viessmann Group
74/75

The company

Viessmann is one of the leading international The Viessmann comprehensive range


manufacturers of efficient heating, industrial As environmental pioneer and technological
and refrigeration systems. trailblazer for the heating sector, Viessmann
has for decades been supplying exceptionally
Sustainability in action clean and efficient systems for heating,
As a family business Viessmann takes the refrigeration and decentralised power
long view and places great value on acting generation. Many of the company's
responsibly; sustainability is firmly enshrined developments are recognised as heating
in the company's principles. For Viessmann, equipment milestones. German Sustainability Award
for Production/Brand/Resource
sustainability in action means striking a
Efficiency
balance between economy, ecology and Practical partnership
social responsibility throughout the company; As part of its comprehensive range,
meeting current needs without compromising Viessmann also offers a wide selection of
the quality of life of future generations. complementary services. These services
include a comprehensive training and further
With its strategic sustainability project, development programme for trade partners
Viessmann demonstrates at its own head at the well equipped training facilities of the
office in Allendorf (Eder) that the energy Viessmann Academy.
and climate policy goals set by the German
government for 2050 can in fact be achieved With its new digital services, Viessmann
today with the help of commercially available offers innovative solutions such as the
technology. operation and monitoring of heating systems
by smartphone. Users benefit from greater Energy Efficiency Award

reassurance and convenience, whilst


contractors can keep a constant eye on the
systems for which they are responsible.

Viessmann Group

Company details Comprehensive range from the


„ Established in: 1917 Viessmann Group
„ Employees: 12,100 „ Boilers for oil or gas
„ Group turnover: 2.37 billion euros „ Combined heat and power generation
„ Export share: 55 percent „ Hybrid appliances
„ 23 production companies in „ Heat pumps
12 countries „ Wood combustion technology
„ 74 countries with sales companies and „ Plants for producing and upgrading biogas
branches „ Solar thermal
„ 120 sales offices worldwide „ Photovoltaics
„ Electric heating and DHW systems
„ Refrigeration systems
„ Accessories
Viessmann Werke GmbH & Co. KG
35107 Allendorf (Eder), Germany
Telephone +49 (0)6452 70-0
Fax +49 (0)6452 70-2780
www.viessmann.com

Your trade partner:

9449 593 - 12 GB 06/2018

Copyright protected content


Duplication and alternative use only with prior written consent.
Subject to modifications.