Sie sind auf Seite 1von 4

Project: 3 STY U MAUNG MAUNG SEIN Page # ___

Engineer: 10/4/2018
Descrip: STF1
ASDIP Foundation 2.6.1 STRAP FOOTING DESIGN www.asdipsoft.com

GEOMETRY SOIL PRESSURES (Comb: Service)


Column to Column Distance ..... 15.58 ft Gross Allow. Soil Pressure ....... 1.70 ksf
Exterior Interior Exterior Interior
Footing Length (X) ..... 12.00 6.00 ft Reaction Force ......... 239.1 -30.7 kip
Footing Width (Z) ....... 12.00 6.00 ft Bearing Pressure ...... 1.66 0.00 ksf
Footing Thickness ...... 18.0 18.0 in OK Bearing Ratio ............ 0.98 0.00 OK
Soil Cover ................... 5.00 5.00 ft
Column Length (X) ..... 18.0 14.0 in MATERIALS
Column Width (Z) ....... 14.0 14.0 in Beam Footings
Column Offset ............ 51.0 0.0 in OK Concrete f'c ............. 3.0 3.0 ksi
Strap Beam Width ................. 14.0 in Reinf. Steel fy .......... 50.0 50.0 ksi
Strap Beam Height ................ 24.0 in Soil Cover Density ................. 120.0 pcf

APPLIED LOADS SLIDING CALCS (Comb. Service)


- Exterior Col. Service Factored Footing-Soil Friction Coeff. .......... 0.45
Axial Force P ........... 137.9 75.0 kip Passive Pressure Coeff. Kp ......... 2.77
Moment about Z Mz 0.0 0.0 k-ft Exterior Interior
Shear Force Vx ........ 0.0 0.0 kip Friction Force at Base 107.6 -13.8 kip
- Interior Col. Service Factored Passive Force @ Ftg .. 10.5 5.2 kip
Axial Force P ........... 8.8 100.0 kip Horiz. Resisting Force ............ 109.5 kip
Moment about Z Mz 0.0 0.0 k-ft Horiz. Sliding Force ................ 0.0 kip
Shear Force Vx ........ 0.0 0.0 kip Sliding Safety Factor .............. 99.99 > 1.5 OK

1
Project: 3 STY U MAUNG MAUNG SEIN Page # ___
Engineer: 10/4/2018
Descrip: STF1
ASDIP Foundation 2.6.1 STRAP FOOTING DESIGN www.asdipsoft.com

EXTERIOR FOOTING INTERIOR FOOTING


- One-way Shear (Comb: Factored) - One-way Shear (Comb: Factored)
Under-strength ϕ Factor ................ 0.75 Under-strength ϕ Factor ................ 0.75
- Side + Side - Side + Side
One-way Shear Vux ... 0.0 0.0 kip One-way Shear Vux ... 14.4 0.0 kip
One-way Shear Vuz ... 36.1 36.1 kip One-way Shear Vuz ... 14.4 14.4 kip
One-way Shear Strength ϕVcx 174.5 kip OK One-way Shear Strength ϕVcx 87.3 kip OK
One-way Shear Strength ϕVcz 168.6 kip OK One-way Shear Strength ϕVcz 84.3 kip OK
Max. One-way Shear Ratio Vu/ϕVc .. 0.21 OK Max. One-way Shear Ratio Vu/ϕVc .. 0.17 OK
- Punching Shear (Comb: Factored) - Punching Shear (Comb: Factored)
Effective Perimeter bo ............. 103.0 in Effective Perimeter bo ............. 114.0 in
Average Effective Depth d ...... 14.5 in Average Effective Depth d ...... 14.5 in
Punching Shear Stress Vu ...... 48.5 psi Punching Shear Stress Vu ...... 54.6 psi
Punching Shear Strength ϕVc .. 164.3 psi Punching Shear Strength ϕVc .. 164.3 psi
Punching Shear Ratio Vu/ϕVc ..... 0.29 OK Punching Shear Ratio Vu/ϕVc ..... 0.33 OK
- Flexure (Comb: Factored) - Flexure (Comb: Factored)
Under-strength ϕ Factor ................ 0.90 Under-strength ϕ Factor ................ 0.90
- Side + Side - Side + Side
Bending Moment +Mux . 126.1 126.1 k-ft Bending Moment +Mux . 35.0 35.0 k-ft
Bending Moment +Muz . 4.3 0.0 k-ft Bending Moment +Muz . 35.0 0.0 k-ft
Use 24 #4 Bars Parallel to X (Bot) , d = 14.8 in Use 12 #4 Bars Parallel to X (Bot) , d = 14.8 in
Use 24 #4 Bars Parallel to Z (Bot) , d = 14.3 in Use 12 #4 Bars Parallel to Z (Bot) , d = 14.3 in
X-Bars Development Length Ratio . 0.91 OK X-Bars Development Length Ratio . 0.41 OK
Z-Bars Development Length Ratio . 0.14 OK Z-Bars Development Length Ratio . 0.41 OK
Min. Bottom Steel Area Ratio ......... 0.97 OK Min. Bottom Steel Area Ratio ......... 0.97 OK
Bending Strength +ϕMnx ..... 250.6 k-ft OK Bending Strength +ϕMnx ..... 125.3 k-ft OK
Bending Strength +ϕMnz ..... 259.6 k-ft OK Bending Strength +ϕMnz ..... 129.8 k-ft OK
Max. Bending Ratio +Mu/ϕMn ....... 0.50 OK Max. Bending Ratio +Mu/ϕMn ....... 0.28 OK

2
Project: 3 STY U MAUNG MAUNG SEIN Page # ___
Engineer: 10/4/2018
Descrip: STF1
ASDIP Foundation 2.6.1 STRAP FOOTING DESIGN www.asdipsoft.com

STRAP BEAM UPLIFT CALCS (Comb: Service)


- Shear (Comb: Factored) Exterior Interior
Use #3 Closed Ties @ 9.0 in along the Beam Uplift Force P ............ 0.0 0.0 kip
Under-strength ϕ Factor ........... 0.75 Footing Selfweight ..... 32.4 8.1 kip
Max. Shear at Beam Vu ........... 28.1 kip Soil Cover Weight ...... 17.1 4.2 kip
Concrete Shear Strength ϕVc .. 23.2 kip Downward Force W .. 49.5 12.3 kip
Reinf. Shear Strength ϕVs ....... 18.5 kip Uplift Safety Factor .... 99.99 99.99 > 1.0 OK
Provided Shear Strength ϕVn .. 41.7 kip OK
Min. Tie Steel Area Av ............. 0.13 in2 LOAD TRANSFER (Comb: Factored)
Min. Tie Steel Area Ratio ......... 0.57 OK Bearing Under-strength ϕ Factor ..... 0.65
Max. Tie Bar Spacing ............... 10.1 in OK Exterior Interior
- Flexure (Comb: Factored) Bearing Stress Pu ....... 0.3 0.5 ksi
Use 6 #7 Top Bars, 6 #7 Bottom Bars Column Bearing ϕPn ... 1.9 1.9 ksi OK
Under-strength ϕ Factor ............ 0.90 Footing Bearing ϕPn ... 3.5 3.5 ksi OK
- Top + Bottom
Effective Depth d ....... 20.2 20.2 in
Max. Moment Mu ........ -196.0 53.9 k-ft
Bending Strength ϕMn -238.4 238.4 k-ft OK
Min. Steel Area Ratio .. 0.31 0.31 OK

DESIGN CODES
Concrete Design ................ ACI 318-08
Load Combinations ............ ASCE 7-05