Sie sind auf Seite 1von 11

SLAB:

SPECIFICATION A-B/1-2

CHARACTERISTICS ACTION
kN
Table NA2, (C11) Permanent, gk ≔ 1.5 ――
MS EN m2
1991-1-1:2010 kN
Variable, qk ≔ 3.5 ――
National Annex pg m2
05

MS EN 1990 Design life = 50 years


Table 2.1

MS EN 1992-1-2 Fire resistance = R60


sec. 5.7

Table 4.1 Exposure class = XC1

Table E.1N Indicative Strength Class C20/25 Structural Class


S4
Table 4.3 N Member with Slab geometry - Reduce Class by 1 Structural Class
S3
fctm ≔ 2.6 MPa

b ≔ 1000 mm

MATERIALS
N
Characteristics strength of concrete, fck ≔ 25 ――
2
mm

N
Characteristics strength of steel, fyk ≔ 500 ――
mm 2

kN
Unit weight of reinforced concrete, γ ≔ 25 ――
m3

Table 4.2 Assumed, ϕbar ≔ 10 mm Seperated


Bars

Design slab, A-B/1-2

Long span, LyAB ≔ 3 m

Short span, LxAB ≔ 2 m

LyAB
――= 1.5 1.5 < 2 , Two-way slab
LxAB

DURABILITY, FIRE & BOND REQUIREMENTS

Table 4.2 Min cover with regard to bond, Cminb ≔ 10 mm Cminb ≔ 10 mm

Table 4.4N Min cover with regard to durability, Cmin.dur ≔ 10 mm

4.4.1.2 Min required axis distance for R60 fire resistance, a ≔ 10 mm

4.4.1.3 Allowance in design for ΔCdev ≔ 10 mm ΔCdev ≔ 10 mm


deviation,

Eq. (4.1) Nominal cover, Cnom ≔ Cminb + ΔCdev = 20 mm


Use:
Use: Cnom ≔ 20 mm Cnom ≔ 20 mm
SLAB THICKNESS

(Table 5.8 EN Minimum thickness for fire resistance = 80 mm


1992-1-2)
Estimated thickness considering deflection control,
2000 10
Table 7.4 N l d ≔ ――= 100 h ≔ 100 + ― + 20
―= 20 20 2
d Try
h ≔ 125 mm h ≔ 175 mm

ACTIONS
kN
Slab selfweight, x ≔ 0.175 m, x ⋅ γ = 4.375 ――
m2
kN
Permanent action (excluding selfweight), gk = 1.5 ――
m2
kN
Characteristics permanent action, gk ≔ gk + ((x ⋅ γ)) = 5.875 ――
m2
kN
Characteristics variable action, qk ≔ qk = 3.5 ――
m2
(Table A1.2 B:
EN1990) kN
Design action, nd ≔ 1.35 ((gk)) + 1.5 ((qk)) = 13.181 ――
m2

ANALYSIS

LyAB
――= 1.5 <2 , Two-way slab
LxAB

(TableA1.2B: Case 4: Two adjecent edges discontinuous


EN1990)

Bending Moment
Table βsx1 ≔ 0.059
3.14:BS8110 βsx2 ≔ 0.078

βsy1 ≔ 0.034
βsy2 ≔ 0.045

Short span
m
Msx1 ≔ βsx1 ⋅ nd ⋅ ⎛⎝LxAB⎞⎠ 2 = 3.111 kN ⋅ ―
m

m
Msx2 ≔ βsx2 ⋅ nd ⋅ ⎛⎝LxAB⎞⎠ 2 = 4.113 kN ⋅ ―
m

Long span
m
Msy1 ≔ βsy1 ⋅ nd ⋅ ⎛⎝LxAB⎞⎠ 2 = 1.793 kN ⋅ ―
m

m
Msy2 ≔ βsy2 ⋅ nd ⋅ ⎛⎝LxAB⎞⎠ 2 = 2.373 kN ⋅ ―
m

MAIN
REINFORCEMENT
Effective Depth

use h ≔ 175 mm h ≔ 175 mm

Effective depth of outer layer,


dx ≔ h - Cnom - 0.5 ((ϕbar)) = 150 mm

Effective depth of inner layer,


dy ≔ h - Cnom - 1.5 ((ϕbar)) = 140 mm

Minimum and Maximum Reinforcement Area

use b ≔ 1000 mm dx ≔ 150 mm OK


⎛ fctm ⎞ mm 2
6.2.1.1 Asmin ≔ 0.26 ⎜―― ⎟ ⋅ b ⋅ dx = 202.8 m ⋅ ――> .0013*b*dx = [ Secondary bar:
⎝ fyk ⎠ m 195 mm2/m. H10-300
So, OK 2
(262 mm / m ) ]
Asmax ≔ 0.04 Ac
mm 2
Asmax ≔ 0.04 ⋅ b ⋅ h = 7000 m ⋅ ――
m
Short Span:
kN ⋅ m
-Midspan, Msx1 = 3.111 ―――
m
((Msx1))
k ≔ ――――
b ⋅ dx 2 ⋅ fck

3.111 ⋅ 10 6
k ≔ ――――― = 0.006
1000 ⋅ 150 2 ⋅ 25

use kx1 ≔ 0.006 < kbal ≔ 0.167

Compression reinforcement is not required

⎛ 0.006 ⎞
‾‾‾‾‾‾‾‾‾‾
z ≔ dx ⋅ ⎜0.5 + 0.25 - ――⎟ = 149.202 mm = 0.995 d ≠ 0.95 d
⎝ 1.134 ⎠

Use z ≔ 0.95 ⋅ dx z ≔ 0.95 ⋅ dx

((Msx1)) ⋅ 10 6
As ≔ ―――― ((3.111)) ⋅ 10 6 mm 2
0.87 ⋅ fyk ⋅ z = ――――――― = 50.188 ――
0.87 ⋅ 500 ⋅ 0.95 ⋅ 150 m

mm 2
As ≔ 50.188 ――
m

mm 2
use Asreqx1 ≔ 50.188 ――
m Use
mm 2
Asprov ≔ 262 ―― H10-300, bot
m
mm 2
Asprov ≔ 262 ――
m
m
Support, Msx2 ≔ 4.113 kN ⋅ ― dx ≔ 150 mm
m

((Msx2))
k ≔ ――――
b ⋅ dx 2 ⋅ fck

4.113 ⋅ 10 6
k ≔ ――――― = 0.007 use kx1 ≔ 0.007 < kbal ≔ 0.167
1000 ⋅ 150 2 ⋅ 25

⎛ 0.007 ⎞
‾‾‾‾‾‾‾‾‾‾
z ≔ dx ⋅ ⎜0.5 + 0.25 - ――⎟ = 149.068 mm = 0.99 d ≠ 0.95 d
⎝ 1.134 ⎠
Use z ≔ 0.95 ⋅ dx
((Msx2)) ⋅ 10 6 2
As ≔ ―――― =66 mm
0.87 ⋅ fyk ⋅ z ――
m

mm 2
Asreqx2 ≔ 66 ―― use H10-300, top
m use H10-300, top
mm 2
Asprov ≔ 262 ――
m

Long Span:
-Midspan,
⎛ m⎞
Msy1 ≔ 1.793 ⎜kN ⋅ ―⎟ use dy ≔ 140 mm
⎝ m⎠

((Msy1))
k ≔ ――――
b ⋅ dy 2 ⋅ fck

1.793 ⋅ 10 6 1
k ≔ ――――― = 0.004 m ⋅ ― kx1 ≔ 0.004 < kbal ≔ 0.167
1000 ⋅ 140 2 ⋅ 25 m

⎛ 0.004 ⎞
‾‾‾‾‾‾‾‾‾‾
z ≔ dy ⋅ ⎜0.5 + 0.25 - ――⎟ = 139.504 mm = 0.996 d ≠ 0.95 d
⎝ 1.134 ⎠

z ≔ 0.95 ⋅ dy

mm 2
((Msy1)) ⋅ 10 6 ((1.793)) ⋅ 10 6 ――
As ≔ ―――― = ――――――= 31 m
0.87 ⋅ fyk ⋅ z 0.87 ⋅ 500 ⋅ .95 ⋅ 140

mm 2
Asreqy1 ≔ 31 ―― use H10-300, bot use H10-300, bot
m

mm 2
Asprov ≔ 262 ――
m

⎛ m⎞
Support, Msy2 ≔ 2.373 ⎜kN ⋅ ―⎟ dy ≔ 140 mm
⎝ m⎠
((Msy2))
k ≔ ――――
b ⋅ dy 2 ⋅ fck

2.373 ⋅ 10 6 1
k ≔ ――――― 2
= 0.005 m ⋅ ― kx1 ≔ 0.005 < kbal ≔ 0.167
1000 ⋅ 140 ⋅ 25 m
⎛ 0.005 ⎞
‾‾‾‾‾‾‾‾‾‾
z ≔ dy ⋅ ⎜0.5 + 0.25 - ――⎟ = 139.38 mm = 0.996 d ≠ 0.95 d
⎝ 1.134 ⎠

Use z ≔ 0.95 ⋅ dy

((Msy1)) mm 2
――
As ≔ ―――― =41 m
0.87 ⋅ fyk ⋅ z

mm 2
use Asreqy2 ≔ 41 ―― use H10-300, top use H10-300, top
m
mm 2
Asprov ≔ 262 ――
m

SHEAR

Short span:

Vsx1 ≔ βsx1 ⋅ nd ⋅ LxAB


Table Vsx1 ≔ 0.54 ⋅ 13.18 ⋅ ⎛⎝2 2 ⎞⎠ = 28.469 kN/m width
3.14:BS8110
Vsx2 ≔ βsx2 ⋅ nd ⋅ LxAB
Vsx2 ≔ 0.35 ⋅ 13.18 ⋅ ⎛⎝2 2 ⎞⎠ = 18.452 kN/m width

Long span:

Vsy1 ≔ βsy1 ⋅ nd ⋅ LxAB


Vsy1 ≔ 0.40 ⋅ 13.18 ⋅ 2 2 = 21.088 kN/m width

Vsy2 ≔ βsy2 ⋅ nd ⋅ LxAB


Vsy2 ≔ 0.26 ⋅ 13.18 ⋅ 2 2 = 13.707 kN/m width
kN
Design shear force, Ved ≔ 28.469 ―― (KN/m width)
m
6.2.2 Design Shear Resistance:
1

2
⎛ 200 ⎞ ∴ not O.K. ∴ not O.K.
k=1+ ⎜――
⎟ = 2.15 > 2
⎝ dx ⎠

use k ≔ 2.0 As1 ≔ 262

As1
ρ1 ≔ ―― =0.00174 0.00174 ≤ 0.02 ∴ O.K. ∴ O.K.
b ⋅ dx
ρ1 ≔ 0.00174

⎛ ―⎞
1
⎜ 3⎟
VRd.c ≔ 0.12 ⋅ k ⋅ ⎝⎛⎝100 ⋅ ρ1 ⋅ fck⎞⎠ ⎠ ⋅ b ⋅ dx

⎛ ―⎞
1
⎜ 3⎟ N
VRd.c ≔ 0.12 ⋅ 2 ⋅ ⎝((100 ⋅ .00174 ⋅ 25)) ⎠ ⋅ 1000 ⋅ 150 = 5.877 ⋅ 10 4― width
m

KN
VRd.c =58.8 ―― width
m

⎛ 3
― ―⎞
1 ⎛ 3
― ―⎞
1

Vmin ≔ ⎝0.035 ⋅ k ⋅ fck ⎟⎠ ⋅ b ⋅ dx


⎜ = ⎝0.035 ⋅ 2 ⋅ 25 ⎟⎠ ⋅ 1000 ⋅ 150

2 2 2 2

kN
=74.25 ――
width
m

So, VRd.c > Ved ∴ O.K. ∴ O.K.

DEFLECTION

dx ≔ 140 mm Since two layers of steel, use smaller d

Percentage of required tension reinforcement

Asreqx1
ρ ≔ ――― 31 ρ ≔ 0.00022 Use ρ ≔ 0.002 Use ρ ≔ 0.002
b ⋅ dx = ――――
1000 ⋅ 140

Reference reinforcement ratio

1

ρo ≔ fck ⋅ 10 -3=0.005 use ρo ≔ 0.005
2
ρo ≔ 0.005
Table 7.4 N Factor for structural system, K ≔ 1.3

Since ρ < ρo , use Eq. 7.16 a

⎛ ―⎞
3

Eq. 7.16 a ⎜ 2⎟
l ⎜ ⎛ ρo ⎞ ⎛ ρo ⎞ ⎟
―= K ⎜11 + ((1.5)) ⋅ ⎛⎝ ‾‾‾
fck ⎞⎠ ⋅ ⎜―⎟ + 3.2 ⋅ ‾‾‾
fck ⋅ ⎜―- 1⎟ ⎟
d ⎝ ⎝ρ⎠ ⎝ρ ⎠ ⎠

⎛ ―⎞
3
⎜ 2⎟
⎛ ⎞ ⎛ .005 ⎞ ⎛ .005 ⎞
= 1.3 ⎜11 + ((1.5)) ⋅ ⎝ ‾‾
25 ⎠ ⋅ ⎜―― ⎟ + 3.2 ⋅ ‾‾
25 ⋅ ⎜―― - 1⎟ ⎟
⎜⎝ ⎝ .002 ⎠ ⎝ .002 ⎠ ⎟⎠

=76.88

Mofification factor for span less than 7m=1.00

Mofification factor for steel are provided ,

As.prove 262
――― = ―― = 8.452
As.req 31

Therefore allowable span - effective depth ratio,

⎛l⎞
⎜― ⎟ = 76.88 ⋅ 1.00 ⋅ 8.452 = 649.79
⎝ d ⎠allowable

Actual span-effective depth ratio,

⎛l⎞ 2000
⎜― ⎟ = ――= 14.286
⎝ d ⎠actual 140

⎛l⎞ ⎛l⎞
⎜― ⎟ < ⎜― ⎟
⎝ d ⎠actual ⎝ d ⎠allowable ∴ O.K. ∴ O.K.

CRACKING

h ≔ 175 mm < 200 mm

Main bar
Smax.slab1 ≔ 3 ⋅ h = 525 mm >400mm ∴ not O.K.
Smax.slab1 ≔ 400 mm
Maximum bar spacing= 300mm < 400mm ∴ O.K.

Secondary bar
Smax.slab2 ≔ 3.5 ⋅ h = 612.5 mm >450mm ∴ not O.K.
Smax.slab2 ≔ 450 mm

Maximum bar spacing= 300mm < 450mm ∴ O.K.

Dimension:
Short span= 2000mm Thickness = 175mm
Long span= 3000mm Concrete cover = 20mm

Reinforcement:
01 H10 - 300 bot.
02 H10 - 300 top.
03 H10 - 300 bot.
04 H10 - 300 top.
05 H10 - 300 top.
06 H10 - 300 top.
07 H10 - 300 top.
08 H10 - 300 top.
09 H10 - 300 top.
10 H10 - 300 top.
DETAILING: