Sie sind auf Seite 1von 6

ELEMENT DESIGN to BS 8110:2005

SOLID SLABS
Originated from RCC11.xls v4.0 © 2006 - 2010 TCC

INPUT LocationD&D: interior span solid slab


Design moment, M 50.0 kNm/m fcu 25 N/mm² gc = 1.50
ßb 1.00 fy 460 N/mm² gs = 1.15
span 3680 mm teel class A
Height, h 250 mm Section location SIMPLY SUPPORTED SPAN
Bar Ø 12 mm Compression steel NONE
cover 40 mm to these bars (deflection control only)
ONE or TWO WAY SLAB
OUTPUT D&D: interior span solid slab Compression steel = NONE
d = 250 - 40 - 12/2 = 204.0 mm Err:520
(3.4.4.4) K' = 0.156 > K = 0.048 ok .
(3.4.4.4) z = 204.0 [0.5 + (0.25 - 0.048 /0.893)]^½ = 192.5 < 0.95d = 193.8 mm
(3.4.4.1) As = 50.00E6 /460 /192.4 x 1.15 = 650 > min As = 325 mm²/m
Err:520 .
(Eqn 8) Err:520
(Eqn 7) Err:520
(3.4.6.3) Err:520
. Err:520 Err:520
. Err:520
ELEMENT DESIGN to BS 8110:2005
RECTANGULAR BEAMS
Originated from RCC11.xls v4.0 © 2006 - 2010 TCC

INPUT Location D&D: Main beam 1st Floor @internal support


Design moment, M 318.0 kNm fcu 25 N/mm² gc = 1.50
ßb 1.00 fy 460 N/mm² gs = 1.15
Span 5700 mm steel class A
Height, h 500 mm Comp cover 25 mm to main reinforcement
Breadth, b 350 mm Tens cover 25 mm to main reinforcement
Tens Ø 20 mm Side cover 25 mm to main reinforcement
Comp Ø 20 mm Section location SIMPLY SUPPORTED SPAN

OUTPUT D&D: Main beam 1st Floor @internal support .


d = 500 - 25 - 20/2 = 465.0 mm
(3.4.4.4) K' = 0.156 < K = 0.168 compression steel required
(3.4.4.4) z = 465.0(0.5 + (0.25 - 0.156/0.893)^½ ) = 361.5 < 441.8 mm
(3.4.4.4) x = (465.0 - 360.4) /0.45 = 232.5 mm
d' = 25 + 20/2 = 35.0 mm .
(Fig 3.3) Gross fsc = 400.0 N/mm² from strain diagram .
(Fig 3.3) net fsc = 400.0 - 0.67 x 25 /1.5 = 388.8 > 0 N/mm²
Excess M = M - Mu = 318.0(0.168 - 0.156) /0.168 = 23.3 kNm
As' = 23.3E6 /388.8 /(465.0 - 35.0) = 139 mm²
PROVIDE 2X20 compression steel = 628 mm² .
(Fig 3.3) fst = 400.0 N/mm² .
As = (23.3E6 /430.0 + 294.7E6 /360.4) /400.0 = 2180 .
PROVIDE 7X20 tension steel = 2199 mm² .
(Eqn 8) fs = 2/3 x 460 x 2,180 /2,199 = 304.0 N/mm²
(Table 3.11) Comp mod factor = 1 + 0.386 /(3 + 0.386) = 1.114 < 1.5
(Table 3.10) Tens mod factor = 0.55 + (477 - 304.0) /120 /(0.9 + 4.202) = 0.833 < 2
(3.4.6.3) Permissible L/d = 20.0 x 1.114 x 0.833 = 18.550
(3.4.6.1) Actual L/d = 5700 /465.0 = 12.258 ok .
ELEMENT DESIGN to BS 8110:2005
SIMPLE TEE & L BEAMS
Originated from RCC11.xls v4.0 © 2006 - 2010 TCC

INPUT Location D&D: Main beam, 1st Floor 8m span


M 1586.0 kNm fcu 25 N/mm² gc = 1.50
ßb 1.00 fy 460 N/mm² gs = 1.15
span 10300 mm steel class A
h 900 mm Comp cover 50 mm to main reinforcement
bw 400 mm Tens cover 50 mm to main reinforcement
bf 2000 mm Side cover 25 mm to main reinforcement
hf 230 mm Section location SIMPLY SUPPORTED SPAN
Tens Ø 25 mm Section shape T BEAM
Top steel 2 no & Ø 12 .

OUTPUT D&D: Main beam, 1st Floor 8m span FAILS on Min Tension Spacing.
d = 900 - 50 - 25/2 = 837.5 mm
(3.4.4.4) K' = 0.156 > K = 0.045
(3.4.4.4) x = 837.5 /0.45(0.5 - (0.25 - -0.197 /0.893)^½) = 99.5 mm (within flange)
(3.4.4.4) z = 837.5 - 0.45 x 99.5 = 792.7 < 795.6 mm
As' = 0 < 226 mm²
(3.4.4.4) As = 1,586.0E6 / 792.7 /460 x 1.15 = 5002 mm² .
PROVIDE 11X25 bottom = 5400 mm² .
(Eqn 8) fs = 2/3 x 460 x 5,002 /5,400 = 284.1 N/mm²
(Table 3.11) Comp mod factor = 1 + 0.014 /(3 + 0.014) = 1.004 < 1.5
(Table 3.10) Tens mod factor = 0.55 + (477 - 284.1) /120 /(0.9 + 1.131) = 1.342 < 2
(3.4.6.3) Permissible L/d = 15.5 x 1.004 x 1.342 = 20.936
(3.4.6.1) Actual L/d = 10300 /837.5 = 12.299 ok
ELEMENT DESIGN to BS 8110:2005
BEAM SHEAR
Originated from RCC11.xls v4.0 © 2006 - 2010 TCC

INPUT Location D&D: Main beam, 1st Floor 8m span, RH end


fcu = 25 N/mm² gc = 1.50 d b
fyl = 460 N/mm² gs = 1.15 768 400
steel class A
Main Steel Link Legs Side cover Shear V UDL
12 25 10 4 25 264.0 97.9
No mm Ø mm Ø No mm kN kN/m

OUTPUT D&D: Main beam, 1st Floor 8m span, RH end


As = 5890 N/mm² = 1.917%
(Eqn 3) v = 264.0 x 10³ /400 /768 = 0.859 N/mm²
(Table 3.8) vc = 0.785 N/mm², from table 3.8
(v - vc)bv = 160.0 N/mm = nominal
PROVIDE 4 legs X10 @ 575 = 160.3 N/mm
(nominal)
.
ELEMENT DESIGN to BS 8110:2005
COLUMN DESIGN SYMMETRICAL RECT-ANGULAR
COLUMN DESIGN

Originated from RCC11.xls v4.0 © 2006 - 2010 TCC

INPUT Location D&D: external column


Axial load, N 1654 kN fcu 40 N/mm²
Moment, M 125.0 kNm fy 500 N/mm²
height, h 300 mm fyv 500 N/mm²
breadth, b 300 mm gm 1.15 steel
Max bar Ø 32 mm gm 1.50 concrete
cover (to link) 30 mm steel class A

CALCULATIONS D&D: external column Link Ø 8 mm


from M As = {M - 0.67fcu.b.dc(h/2 - dc/2)}/[(h/2-d').(fsc+fst).gm] (3.4.4.1)
from N As = (N - 0.67fcu.b.dc/gm) / (fsc - fst) (Figs 2.1, 2.2 & 3.3)
where As = Ast = Asc: dc=min(h,0.9x)
.67fcu/gm = 17.9 N/mm² d' = 54.0 mm
fy/gm = 434.8 N/mm² d = 246.0 mm
from iteration, n.a. depth, x, = 225.9 mm dc = 203.3 mm
0.67.fcu.b.dc/gm = 1089.7 kN
Steel comp strain = 0.00266
Steel tens strain = 0.00031
Steel stress in comp. face, fsc = 435 N/mm² (Comp. stress in reinf.)
Steel stress in tensile face, fst = 62 N/mm² (Tensile stress in reinf.)
from M, As = 1515 mm² rom N, As = 1516 mm²
OK
OUTPUT D&D: external column
As req'd = 1515mm² T&B:- PROVIDE 4H32
(ie 2H32T&B - 1609mm² T&B - 3.6% o/a - @
192cc.)
Links : - PROVIDE H8 @ 300
.

Strain diagram 5
Stress diagram
2
17.9 N/mm²
12
2

Notes

9 Stresses in N/mm2

Compression +ve
7 1
- - - Neutral axis
Disclaimer
All advice or information from MPA-The Concrete Centre is intended for those who will evaluate the significance and limitations of its contents
and take responsibility for its use and application. No liability (including that for negligence) for any loss resulting from such advice or
information is accepted by MPA-The Concrete Centre or its subcontractors, suppliers or advisors. Users should note that all MPA-The Concrete
Centre software and publications are subject to revision from time to time and they should therefore ensure that they are in possession of the
latest version.

This spreadsheet should be used in compliance with the accompanying publication 'User Guide RC Spreadsheets: v4' available from The
Concrete Centre www.concretecentre.com/rcdesign Tel +44 (0)1276 606800

Status of spreadsheet This spreadsheet is shareware but may not be used for commercial purposes until the user has
Public release version. registered with The Concrete Centre using the licence validation form available on The
Concrete Centre website www.concretecentre.com/rcdesign

Revision history RCC11 Element Design.xls

Date Version Action Size (kB)


30-Mar-10 RCC11 v4.0 Re-badged as TCC/Mineral Products Association. 376
13-May-09 RCC11 v3.6 bf used instead of bw for compression steel modification factor on TEE-BEAM. 328
19-Dec-07 RCC11 v3.5 x/d limit added in TEE-BEAM. 299
16-Nov-06 RCC11 v3.4 Additional compressions teel option added to SLAB. 300
4-Oct-06 RCC11 v3.3 Corrections to COLUMN!L9:L16. 298
28-Jun-06 RCC11 v3.2 v3 release. Page nos, User Guide and registration details amended. 298
15-Feb-06 RCC11 v3.1 Differentiation between flat slabs and other slabs on SLAB page. 331
20-Oct-05 RCC11 v3.0 Updated to 2005 versions of BS8110 & BS8666 317
3-Feb-04 RCC11 v2.2 Minor correction to cell N12 on "SLAB" (> changed to <). 289
21-Jan-03 RCC11 v2.1 DETR logo replaced by DTI. 289
11-Oct-02 RCC11 v2.0 Version 2 enhancements 304
1-Oct-02 RCC11 v1.7 COLUMN: Minor mods to N37:U37; Chart at U2 reactivated. 284
22-Jun-01 RCC11 v1.6 Addition of input controls. 284
26-Jan-01 RCC11 v1.5 Addition of input controls. 283
5-Dec-00 RCC11 v1.4 SHEAR:K22 lateral link spacing corrected. 189

24-Nov-00 RCC11 v1.3 SHEAR:C19 & C20 reformatted, and lateral link spacing check added (C Braidwood). 185

30-May-00 RCC11 v1.2 R Lawson comments incorporated (gc refs etc). 183
Revisions to TEE~BEAM. Option of required compression rebar added. Neutral axis, x
8-May-00 RCC11 v1.1 allowed below flange soffite - IStructE 'Green book' method followed where flanges 182
outside bw have z = d-hf/2, and bw acts as beam.

First public release.


3-Aug-99 RCC11 v1.0 190
Includes b version comments & chg mods to COLUMN

Das könnte Ihnen auch gefallen