Hazardous Area Classi cation Questions 


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 1/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Download Template (Free)


Find Templates, Download Now

FreeTemplateFinder OPEN

What is a hazardous area?


A hazardous area classification is one in which concentrations of
flammable substances are present or can be expected to be present.

These concentrations are at a level which requires specific safety


standards and precautions to be taken in the construction, installation

This website uses cookies to improve your and maintenance
experience. of you're
We'll assume all electrical equipment.
ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 2/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

A “hazardous area” is defined as an area in which the atmosphere


contains, or may contain in sufficient quantities, flammable or explosive
gases, dusts or vapours. In such an atmosphere a fire or explosion is
possible when three basic conditions are met. This is often referred to as
the “hazardous area” or “combustion” triangle.

In order to protect installations from a potential explosion a method of


analysing and classifying a potentially hazardous area is required.

The purpose of this is to ensure the correct selection and installation of


equipment to ultimately prevent an explosion and to ensure safety of
life.

The methods used to classify an installation can vary depending upon


which part of the world it is located, but generally there are two main
types of classification.

In countries that have adopted the IEC (International Electrotechnical


Commission) philosophy this is referred to as Zoning whilst in North
American installations are classified by Classes, Divisions and Groups to
ascertain the level of safety required.

How Hazardous Area classi ed ?


A Hazardous Area is defined by three main criteria, these being:

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
The type of hazard (groups)
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 3/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

The auto-ignition temperature of the hazardous material


(temperature or “T” rating)
The likelihood of the hazard being present in flammable
concentrations (zones)

Explain about  Type of Hazard (Groups) ?


The type of hazard will be in the form of either a gas or vapour or a dust
or fibre.

The classification of these hazardous is primarily divided into two groups


depending on whether it is in a mining or above surface industry. These
are defined below:

Group I – electrical equipment for use in mines and underground


installations susceptible to firedamp Group II and Group III -electrical
equipment for use in surface installations

Groups II & III are further sub-divided depending upon the hazard.
Group II gases are grouped together based upon the amount of energy
required to ignite the most explosive mixture of the gas with air. Group
III dusts are subdivided according to the nature of the explosive
atmosphere for which it is intended.


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 4/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

ALSO READ : DIFFERENCE BETWEEN EXPLOSION PROOF


AND INTRINSICALLY SAFE

Explain about  Auto Ignition Temperature or “T”


Rating ?
The hazard level of the gases increases from gas group IIA to IIC with
group IIC being the most severe.

Substances in this group can be ignited very easily with Hydrogen being
the most at risk to ignition. The temperature class is based on the auto-
ignition temperature of the gas.

If a hazardous is present the equipment used within the installation


must be given an appropriate “T” classifi cation in order to maintain the
integrity.

If that hazardous is, say, hydrogen, then all equipment used must meet
the “T6” rating. This means that all equipment used must not have a
surface temperature of greater than 85˚C.

Any equipment used that can generate a hotter surface temperature of


greater than 85˚C must not be used as this will then increase the
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
likelihood of an explosion by igniting the hydrogen in the atmosphere.
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 5/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

The Likelihood of the Hazard


The likelihood of the hazard being present in a concentration high
enough to cause an ignition will vary from location to location.

For most installations this risk is dependant upon how long the hazard
(gas, vapour, dust or fibre) is present.

In order to classify this danger an installation is divided into areas of risk


depending upon the amount of time the hazardous is present. These
areas are referred to as Zones.

For gases and vapours and dusts and fibres there are three zones:

classi cation of hazardous locations ?


Hazardous locations are classified into zones so as to facilitate the
selection of the correct electrical apparatus and to ensure that the
electrical design and installation meets the specified requirements to be
used in different areas. 
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 6/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

The zone classification is based on the likelihood and the duration of an


explosive atmosphere.

The zone classification for gases is divided into three zones, namely
Zone 0, Zone 1 and Zone 2 and for dusts Zone 20, Zone 21 and Zone 22.

De nition of hazardous area zones (AS/NZS


60079.10):
Zone 0
“Place in which an explosive atmosphere consisting of a mixture with air
of flammable substance in the form of gas, vapour or mist is present
continuously for long periods or frequently”

As per experts experience that a Zone 0 condition is rarely encountered


and is limited mainly to confined spaces (such as the vapour space of
closed process vessels, closed storage tanks and closed containers),
although it can occur in larger rooms, such as chemical plants. From the
Institute of Petroleum (IP 15) an exposure exceeding 1000 hours per
year is often used.

Zone 1
“Place in which an explosive atmosphere consisting of a mixture with air
likely to
of flammable substances in the form of gas, vapour or mist isAccept
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.
occur in normalRead
operation
More occasionally”
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 7/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

A Zone 1 classification usually includes locations where volatile


flammable liquids or liquefied flammable gasses are transferred; gas
generator rooms; inadequately ventilated pump rooms for flammable
gases or for volatile flammable liquids; and most other locations where
hazardous concentrations of flammable vapours or gases can occur in
the course of normal operations. IP 15 stipulates between 10 hours and
1000.

Zone 2
“Place in which an explosive atmosphere consisting of a mixture with air
of flammable substances in the form of gas, vapour or mist is not likely
to occur in normal operation but, if it does occur, will persist for a short
period only”

Generally, for an area to be classified as a Zone 2 location the following


conditions shall normally be regarded as the minimum requirements for
the area:

1. the area is so well ventilated that if an abnormal conditions arises,


ignitable concentrations of the gas or vapour are rapidly dispersed;
and
2. complete segregation from Zone 1 locations is ensured.

In this case an expose to flammable vapours or gases of less than 10


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
hours per annum is prescribed in IP 15.
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 8/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

ALSO READ : NEMA ENCLOSURE TYPES STANDARDS

Explain about Protection Concepts ?


There are varying types of equipment that can be used within these
zones to ensure that the potential for an explosion is removed or greatly
reduced.

This equipment must be designed and manufactured in accordance with


particular construction parameters known as protection concepts.

Essentially these concepts fall under four main methods.

These methods are detailed below along with a brief description of


some of the concepts:


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 9/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Explain Ex i Intrinsic Safety ?


A protection concept in which the electrical energy within the equipment
is restricted to a level which is below that what may cause an ignition or
to limit the heating of the surface of the equipment.

There are two main sub types to Ex i protection, these being “ia”
and “ib”.

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 10/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Type “ia” protection allows for the occurrence of two faults during
operation
Type “ib” protection allows for the occurrence of one fault during
operation.

Explain Ex d Flameproof ?
The equipment that may cause an explosion is contained within an
enclosure which can withstand the force of an explosion and prevent
transmission to the outside hazardous atmosphere.

This method of protection also prevents the hazardous atmosphere


from entering the enclosure and coming into contact with equipment.

Explain Ex m Encapsulation ?
A protection concept where by equipment that could potentially cause
an ignition is encapsulated within a compound or resin so as to prevent
contact with the explosive atmosphere.

The concept also limits the surface temperature of the equipment under
normal operating conditions.

Explain Ex e Increased Safety ?


Precautions are applied to the installation to ensure increased security
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
against the possibility
Read More
of excessive temperatures and sparks from
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 11/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

electrical equipment.

Equipment that normally causes sparks is excluded from use within this
method of protection.

Explain Ex p Pressurised ?
One process ensures that the pressure inside an enclosure is sufficient
to prevent the entrance of a flammable gas, vapour, dust, or fibre and
prevent a possible ignition.

Another process maintains a constant flow of air (or an inert gas) to


dilute to take away any potentially explosive atmosphere.

Explain Ex o Oil Immersion ?


All equipment that has the potential to arc and potentially cause an
ignition is immersed in a protective liquid or oil.

The oil provides an insulating method to prevent ignition.

Explain Ex q Powder Filling ?


All equipment that has the potential to arc is contained within an
enclosure filled with quartz or glass powder particles.

The powder filling prevents the possibility of an ignition. 


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 12/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Explain Ex n Non-Sparking ?
A type of protection where precautions are taken so that electrical
equipment that has the potential to arc is not capable of igniting a
surrounding explosive atmosphere.

ORA Oxford Summer Camp


Ad Book asap to guarantee your
choices for this summer
Oxford Royale Academy

Book now

This can be further categorized as follows:

Ex nA – Where components used in construction are non-sparking


Ex nC – Where components used in construction are non-incendive
Ex nR – Where components used are tightly enclosed to restrict the
breathing and prevent ignition
Ex nL – Where components used in construction do not contain
enough energy to cause an ignition

Explain Ex s Special ?
This method of protection, as its name indicates, has no specific

This website uses cookies to improve your parameters orassume
experience. We'll construction rules.
you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 13/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

In essence it is any method of protection which can provide a pre-


determined level of safety to ensure that there is no potential for an
ignition.

As such it does not fall under any specific protection method and may in
fact be a combination of more than one.

ALSO READ : DIFFERENCE BETWEEN INTRINSIC SAFE


AND NON-INTRINSIC SAFE CABLES

Explain Ingress Protection ?
Another consideration in the protection of equipment in hazardous
areas is the safeguarding against the ingress of solid foreign objects and
water.

This is known as the degree of ingress protection and is commonly


referred to as the IP Code.

The relevant standard for the degree of ingress protection is IEC 60529.

An overview of the IP code as defined in the standard is detailed below:


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 14/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Explain Operational Temperatures ?
All equipment used within hazardous areas has an operational
temperature band or limit. This is often referred to as the “Tamb” and
defines the upper and lower ambient temperatures of which the
equipment is approved for use in.

As defined in IEC 60079-0 the standard limits are – 20˚C to +40˚C.


Where the operation temperatures of the equipment fall between these
parameters no additional marking is required.

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 15/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

However, if they are outside these parameters than the specific


temperatures need to be identified.

What are the Methods of Explosion Protection ?

Explain Marking of Hazardous Area Equipment ?


All equipment for use in hazardous areas should be marked as
prescribed in 60079-0.

As a general rule this includes, where appropriate, such information as:

Company/Manufacturers name and address


Hazardous area certificate number(s)
Protection concept -Gas group(s)
Temperature class 
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Ambient temperature
Read More range
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 16/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Product identification
Serial number and year of manufacture
Electrical parameters
CE marking and ATEX notified Body ID number
ATEX coding -IP code

ALSO READ : ZONE VS CLASS/DIVISION

Explain Basic UL / CSA / NEMA Enclosure Types ?


Type 3 : An enclosure which is intended for outdoor use primarily to
provide a degree of protection against windblown dust, rain, sleet and
damage from external ice formation

Type 3R : An enclosure which is intended for outdoor use primarily to


provide a degree of protection against falling rain and damage from
external ice formation

Type 3S : An enclosure which is intended for outdoor use primarily to


provide a degree of protection against rain, sleet, windblown dust, and
to provide for operation of external mechanisms when ice laden

Type 4 : An enclosure which is intended for indoor or outdoor use


This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
primarily to provide a degree of protection against windblown rain and
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 17/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

dust, splashing water, hose directed water and damage from external
ice formation

Type 4X : An enclosure which is intended for indoor or outdoor use


primarily to provide a degree of protection against corrosion, windblown
rain and dust, splashing water, hose directed water and damage from
external ice formation

Type 6 : An enclosure which is intended for indoor or outdoor use


primarily to provide a degree of protection against falling dirt, hose
directed water, the entry of water during occasional temporary
submersion at a specified depth and damage from external ice
formation.

Type 6P : An enclosure which is intended for indoor or outdoor use to


primarily to provide a degree of protection against falling dirt, hose
directed water and the entry of water during prolonged submersion at a
specified depth and damage from external ice formation.

Why perform electrical equipment in hazardous


areas inspections ?
Perhaps you have heard the expression ‘if it’s not broken don’t fix it’.

The same can be said for Electrical Equipment in Hazardous Areas



This website uses cookies to improve your (EEHA) inspections
experience. We'll assume and
you'rethere
ok withis often
this, a can
but you great deal
opt-out of wish.
if you resistance
Acceptfrom
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 18/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

engineering and production managers to perform electrical inspections


which may involve the isolation certain equipment or partial plant
shutdown.

It is a fact that if the electrical inspector lacks the necessary experience,


the EEHA inspection could indeed do more harm than good, resulting in
damage to electrical apparatus, tripping of electrical circuits or extended
isolations.

For this reason only competent personnel should be employed for the
purpose of performing EEHA inspections.

Using a competent electrical inspector will provide the owners or users


of the plant with a condition assessment of the electrical installation in
hazardous areas to ensure that it is maintained in a satisfactory
condition.

It is also a requirement of AS/NZS 2381.1:2005 Section 4 that EEHA


inspections be performed on a regular periodic basis or under
continuous supervision by competent personnel.

Before embarking upon an inspection of electrical equipment within a


hazardous area, the hazards associated with the flammable gas or
vapour must be understood and the extent of the hazardous zone must
be clearly defined. It is a fruitless exercise to begin an EEHA inspection

This website uses cookies to improve your without a We'll
experience. clear definition
assume of with
you're ok the this,
hazardous zones.
but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 19/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

Internationally, the classification of hazardous areas has traditionally


been carried out by individuals  representing the legal owners/users of
the plant.

Often these persons lack expertise in hazardous areas classifications as


well as the specific knowledge of the properties of the flammable
materials. As a result, inconsistencies may exist in the limits of the
hazardous zones.

However, in more recent times hazardous areas classification has


tended to be carried out by professional multidisciplinary engineering
consultancies specialising in hazardous locations classifications.

The electrical inspector performing the EEHA inspection should verify


that the existing area classification remains correct and that there have
been no changes to plant or processes that may affect the hazardous
zones.

Does all electrical equipment for use in hazardous


areas have to be submitted to a test house for
certi cation?
No, electrical equipment in category 1, i.e. suitable for use in Zone 0,1
and 2 must be submitted to a test house (now known as a notified body)
for EC Type Examination Certification. 
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 20/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

This also applies to category 2 equipment (i.e. suitable for use in Zone 1
and 2) .

Equipment in category 3, i.e. suitable only for use in Zone 2 need only be
subject to self certification by the manufacturer.

For all electrical equipment for use in hazardous areas, the


manufacturer must issue an EC Declaration of Conformity with his
product.

If an enclosure is marked II 2 GD and also EExd 11C


T5 T100 IP 66, what is the meaning of the upper
case and the lower case ‘d’s?
The upper case D is part of the ATEX labelling and indicates that the
equipment is for use in areas where the explosion hazard is Dust (the G
indicates Gas Hazard).

The lower case d indicates the method of Ex protection, in this case


flameproof (d from the German Druckefest Kapselung meaning pressure
proof enclosure).

I have an EExe electric motor which is labelled as


T3, I understand this to mean that the
This website uses cookies to improve your temperature
experience. We'll assume reached bybut any
you're ok with this, partif you
you can opt-out ofwish.
the Accept
motor
Read More
https://instrumentationtools.com/hazardous-area-classification-interview-questions/ 21/46
4/14/2019 Hazardous Area Classification Questions - Instrumentation Tools

will not be any greater than 200°C. Is this the


case and do I need to consider ambient
temperature e ects?
This is true and if there is no ambient temperature range marked on the
equipment then the T rating is based on a range of -20°C to +40°C.

Any other range must be marked on the label.

A ameproof EExd enclosure has a 32mm entry


and we need to use it for a 20mm cable gland, is
it permissible to use two reducers to achieve
this?
No, EN 60079-1, the standard for flameproof equipment states that for
any entry only one reducer can be used, also that reducers or adapters
cannot be used at all with stopping plugs.

Also Read : ATEX Ratings, Intrinsic Safety, Hazardous Areas and