Sie sind auf Seite 1von 1

ADJUSTABLE PRESSURE SWITCH F4 SERIES

“F4” adjustable pressure switches allow a micro-switch commutation once a


preset pressure value is reached. Working on the central screw in the P2 execution
Ø 24 or intercepting the regulator dowel put inside the instrument using a 2mm
40
Execution hexagonal screw, rotating the operating point in hourly sense to increase and vice-
with P2 versa to decrease. Mechanical stops protect both the spring and the micro-switch
electric 24 hexagon from over pressurization.
connection
Technical features:
Body: 24 mm hexagonal in zinc-plated carbon steel
Assembly: in every position
Working temperature: from - 25°C to + 85°C
Execution
with P3 Ø 26,5 46 Switching frequency: 90 cycles/min
electric Switching accuracy: ± 4% of the pressure settled to 20°C
connection
Operating point: adjustable through an internal screw
24 hexagon
Fixed hysteresis value:
- membrane execution ~ 10% of the settled value
- piston execution ~ 15% of the settled value
~ 38
Weight: 0,05 Kg
Mechanical life: 106 cycles at 70 bar (1000 psi) at 20°C
Execution Electric Features:
Ø 26 66 - Maximum load: 0.5 Ampère at 250 Volt AC (see dedicated page)
with M2
electric F4/P3 : only with protection cap, without P1 2 A at 48VAC
connection - Exchange contacts NO and NC
24 hexagon
- Electric connection according to DIN 43650 for M2 and M3
- Electric protection according to DIN 40050:
IP65 for M2/M3 execution
IP54 for P2 and P3 execution
~ 49
Warranty: see dedicated page
Spare parts: see dedicated page
Execution
Also available:
with M3 Ø 29 69 - F4X with fluid connection part made in AISI 316 stainless steel
electric
- F4L body in brass
connection
-WF4 vacuum switch with adjustable field from 0.15 to 0.75 [bar]
- Seals in Viton, EPDM, PTFE
24 hexagon Note: Certificate ATEX only for M2 and M3 execution

HOW TO ORDER
F4 . . . . . / . . / .. ..
Switching Type Type Type of
P Body Hydraulic Preset Protection
pressure Execution of of Condition Electric
Max material Connection Value Cup
range Seal microswitch Connection
Bar Bar Bar
0
R 0,2>2,5 Membrane 25 X ⅛” BSP V
P2
Connection
AISI316L VITON
1 with screw
L ¼” BSP P1
S 1>12 Membrane 25 D P3 Rubber cup
BRASS T
2 G Indicate means protection
PTFE
Golden the value down Connection only on
B ⅛”BSPT Contact if you pressure with request
T 5>50 Piston 200 NICKEL
want the setting Fast-on necessary to
PLATED 3 E
pressure protect the
BRASS M10x1 EPDM
If omitted switch instrument
V 10>100 Piston 300 means already M2 from dirt and
if 4
standard preset U 16x16 moisture
omitted ⅛”NPT H
contact in factory means up connector
means HNBR
pressure (only for P2 and
body 5
Z 20>200 Piston 300 setting P3 execution)
in zinc ¼”NPT M3
plated if omitted
30x30
carbon means
6 connector
Y 50>400 Piston 600 steel NBR
¼”BSPT

We reserve us the right to make modifications to the construction without prior notice. 7
Copyright © www.fox.it
Fox S.r.l. via Romagna 6 – 20090 Opera – Milano
Tel +39.02.57.60.00.33 - +39.02.57.60.65.43 Fax +39.02.57.60.01.76