Technical Parameters Proposed by the Bidder

Technical Schedule No.1 (FOR RAW WATER PUMP HOUSE (ELECTRICAL)

The Bidder shall complete the technical schedules and furnish data as per the following details along
with his tender.

3. For Electrical Works

1. Main Raw Water Pump Motors

1) Name of the Manufacturer

2) Performance ISS/BSS.IEC

3) Frame size of the motor

4) Rated continuos output at 45o C and altitude of 150 m.: KW

5) Rate voltage: V

6) Rated full load current: A

7) Full load efficiency

8) Full load power factor

9) Full load torque : Kgfm

10) Starting current: A

11) Staring torque: Kgfm

12) Full load speed: rpm

13) Full load slip

14) GD2 of the motor: Kgf/ m2

15) Protection provided

16) Performance curves of the pump offered

17) Maximum output at an ambient temperature of 450C: Kw

18) Starting current at 80% of the rated voltage: A

19) Starting torque at 80% of the rated voltage: Kgfm

20) Permissible over load and duration: A

21) Maximum permissible temperature rise over an maximum ambient temperature of


45oC

• Starter cover thermometer: Deg C


Page 2of 16

• Starter winding: Deg C

• By embedded thermal detector Deg C

• By resistance Deg C

• By thermometer: Deg C

Permissible variation in frequency

• plus ...........................%

• minus ........................%

22) Weight of the motor:…. Kg

2. Transformers

1. Manufactured by

2. Quantity offered Nos.

3. Type of cooling

4. Rated KVA

5. Material of winding

6. Rated Voltage of

a) HV winding KV

b) LV winding KV

7. Rated frequency Hz

8. Installation for outdoor type Yes/No

9. Temperature rise
o
a) Of oil by thermometer C
o
b) Of winding by resistance C

10. Number of phases

11. Vector group reference

12. Tapping on winding

a) On load/off load taps


Page 3of 16

b) Total tap range

c) Tapping steps

d) On HV/LV windings

13. Guaranteed no load losses at 75ºC, rated frequency and rated voltage KW

14. Guaranteed load losses at principle tapping, rated


current, rated voltage, rated frequency and average
winding temperature of 75oC KW

15. Tolerance on losses %

16. Percentage impedance between each pair of


windings at rated current, rated frequency and
75 0C. %

17. Efficiency at rated voltage, rated frequency, 75oC, full load and at

a) Unity power factor %

b) O.8 p.f. lagging %

18. No load current and power factor at rated voltage and rated frequency

19. Impulse test voltage for

a) HV winding KV (peak)

b) LV winding KV (peak)

20. One minute power frequency withstand voltage for

a) HV winding KV (rms)

b)LV winding KV (rms)

21. Clearance in air

a) between phases mm

b) between phases and earth mm

22. Overall dimensions (length X breadth X height) mm X mm X mm

23. Whether all the fittings are provided on the transformer as per specification
Yes/No

24. Are the following designed for oil filling under 250 mm of mercury

a) tank

b) conservator

c) radiators
Page 4of 16

d) bushings

e) fittings

25. Acceptance of test, inspection and tolerance as per specification Yes/No

3. 11 KV / 3.3 KV Switchgear

3.1 General

1. Manufactured by

2. Manufacture's type designation

3. Short time (one second) withstand rating KA


(rms)

4. Clearances :

• between phases mm

• between live parts and earth mm

• microsecond withstand voltage KV (peak)

5. One minute power frequency withstand voltage KV


(rms)

6. Degree of protection

7. Thickness of frame mm

8. Thickness of sheet steel

• Frame enclosure mm

• Doors mm

• Covers mm

9. Sheet steel hot rolled or cold rolled HR/CR

10. Dimensions of cubicles (width X depth X height) mm X mm X mm

11. Dimensions of complete panel (width X depth X height) mm X mm X


mm

12. Drawout space required in front mm

13. Total weight of Cubicle Kg

3.2 Vacuum Circuit Breakers

1. Manufactured by

2. Manufacturer's type designation


Page 5of 16

3. Type

4. Rated voltage KV

5. Rated current for various circuit breakers

6. Rated symmetrical interrupting capacity at rated voltage: KA

7. Making capacity (peak value) KA

8. Duty cycle

9. Microsecond wave impulse withstand voltage KV


(peak)

10. One minute dry withstand voltage KV (rms)

11. Maximum temperature rise over the average ambient, when carrying

12. continuous rated current under site conditions ºC

13. Whether the circuit breaker is designed to close and latch on making

or whether it is fitted with making current release

14. Whether the current breaker is trip free Yes/No

15. Method of closing

• Normal

• Emergency

16. Normal voltage of closing coil V

17. Power required to operate closing coil at normal voltage W

18. Normal voltage of tripping coil V

19. Power required to operate tripping coil at normal voltage W

20. Whether tripping coil is capable of operating at 70% rated voltage

3.3 Bus Bars

1. Material

2. Bus bar cross-section mm X mm

3. Type of insulation

4. Minimum clearances :

• Between phases mm

• Phase to nearest earthed part mm


Page 6of 16

5. Continuous current rating at site Amps conditions (45 deg. ambient)

6. Temperature rise over the specified ambient temperature when carrying


continuous rated current oC

3.4 HT Fuses / L.T. Fuses

1. Make

2. Type

3. Rated voltage

4. Rated current amps

3.5 EARTH BUS

1. Material

2. Cross section mm X mm

3.6 Indicating Instruments

1. Voltmeter Ammeter

2. Make

3. Type

4. Accuracy class

5. Voltage/current coil rating VA

6. Voltage/current coil burden VA

7. Case size

8. Angle of deflection

3.7 Current Transformer

1. Make

2. Type

3. Rated voltage KA (rms)

4. Class of insulation

5. Rated short time current for i sec. KA (peak)

6. Rated dynamic current

7. One minute power frequency test voltage

8. No. of cores
Page 7of 16

9. CT ratio

10. Output

11. Measuring CT/core VA

12. Protection CT/core VA

13. Accuracy class

14. Measuring CT/core

15. Protection CT/core

3.8 Voltage Transformer

1. Make

2. Type designation

3. Ratio

4. Output - Secondary VA

5. Accuracy class

6. Class of insulation

7. One-minute power frequency test voltage KV (rms)

3.9 Protective Relay

1. Make

2. Type

3. Current coil rating A

4. Current coil burden VA

5. Protection covered Yes/No

6. IDMT O/C Yes/No

7. Inst. O/C Yes/No

8. Inst. earth fault Yes/No

9. Descriptive pamphlet no. (to be enclosed with the tender)

10. Acceptance of Inspection and Test as per specification Yes/No

4. 415 V Switchgear

4.1 General

1. Manufactured by
Page 8of 16

2. Manufacturer's type designation

3. Whether single front or double front

4. Degree of protection

5. Whether circuit breaker cubicle is fully drawout type

6. Short time (one second) withstand rating for bus bars and droppers KA (rms)

7. Momentary withstand rating for bus bars and droppers KA (peak)

8. Clearances :

• between phases mm

• between live parts and earth mm

9. One minute power frequency withstand voltage for power circuits KV (rms)

10. Thickness of frame mm

11. Thickness of sheet steel

• Frame enclosure mm

• Doors mm

• Covers mm

12. Sheet steel hot rolled or cold rolled HR/CR

13. Dimensions (width X depth X height)

• Complete panel mm X mm X mm

14. Drawout space required in front mm

15. Total weight of cubicle:

4.2 Circuit Breakers

1. Manufactured by

2. Manufacturer's type designation

3. Type

4. Rated voltage V

5. Rated frequency Hz

6. Rated current
Page 9of 16

• Nominal A

7. Making capacity (peak value) KA

8. Rated symmetrical breaking capacity at 415 V KA

9. Duty cycle

10. Maximum temperature rise over the reference ambient, when carrying

11. continuous current under site conditions oC

12. Whether the circuit breaker is designed to close and latch on making or

13. whether it is fitted with making current release ?

14. Whether the circuit breaker is trip free ?

15. Method of closing :

• Normal

• Emergency

16. Normal voltage of closing coil V (AC/ DC)

17. Normal voltage of tripping coil V (AC/ DC)

18. Power required to operate closing coil at normal voltage W

19. Power required to operate tripping coil at normal voltage W

20. Whether tripping coil is capable of operating at 70% voltage

4.3 Bus Bars

1. Material

2. Bus bar cross-section mm X mm

3. Type of insulation

4. Minimum clearances :

• Between phases mm

• Phase to nearest earthed part mm

5. Continuous current rating Amps

6. Temperature rise over the specified ambient temperature oC

4.4 Isolating Switches

1. Make
Page 10of 16

2. Type

3. No. of pole

4. Rated voltage Volts

5. Rated continuous current Amps

4.5 Fuses

1. Make

2. Type

3. Rated voltage V

4. Rated current Amps

4.6 Motor Contactor

1. Make

2. Type

3. Applicable standard

4. No. of poles

5. Rated voltage for main contacts V

6. Rated voltage of coil V

7. Rated voltage of auxiliary contacts V

8. Rated (thermal) current

9. 45 KW motor Amps

10. 22 KW motor Amps

11. 3.7 KW and below motor Amps

12. Rated duty

13. Utilisation category

14. Rated making capacity KA (peak)

15. Rated breaking capacity KA (rms)

16. Thermal overload relay

• Setting range

17. Whether single phasing prevention provided

18. High voltage test values :


Page 11of 16

• Main circuits V (rms)

• Control and auxiliary circuits v (rms)

4.7 Indicating Instruments

1.0 Voltmeter

1.1 Make

1.2 Type

1.3 Accuracy class

1.4 Voltage coil rating

1.5 Voltage coil burden VA

1.6 Case size

1.7 Angle of deflection

2.0 Ammeter

2.1 Make

2.2 Type

2.3 Accuracy class

2.4 Current coil rating A

2.5 Current coil burden VA

2.6 Case size

2.7 Angle of deflection

3.0 Load Manager With MD

3.1 Make

3.2 Type

3.3 Accuracy class

3.4 Voltage coil rating V

3.5 Current coil rating A

3.6 Voltage coil burden VA

3.7 Current coil burden VA

3.8 Case size

3.9 Parameters
Page 12of 16

4.8 Current Transformers

1. Make

2. Type designation

3. Ratio

4. Output VA

5. Accuracy class

6. Class of insulation

7. One minute power frequency test voltage KV (rms)

8. Rated short time current for one second KA (rms)

9. Rated dynamic current KA (peak)

4.9 Push Button

1. Make

2. Type designation

3. No. of contacts :

4. Normally open

5. Normally closed

6. Contact rating at 240 AC A

4.10 Indicating Lamps

1. Make

2. Type

3. Voltage V

4. Series resistor value Ohms

5. Acceptance of inspection and testing as per specification Yes/No

6. Common annunciation Yes/No

4.11 Control/Selector Switches

1. Make

2. Type designation

3. Voltage grade V

4. Current ratings :
Page 13of 16

5. Make and carry A

6. Break A

7. Spring return or stayput

8. Type of handle

9. No. of positions

10. No. of poles/ways

4.12. Wiring

1. Voltage grade

2. Insulation

3. Conductor material

4. Size of conductor mm2

5. Colour code used

6. Type of terminals

7. Size of terminals

5. Cables

5.1 11/ 3.3 KV Grade XLPE Cables

1. Manufacturer and cable type

2. Rated voltage grade

3. Whether suitable for use at rated voltage on earthed system

4. Permissible voltage and frequency variation for satisfactory operation

• Voltage %

• Frequency %

• Combined voltage and frequency %

5. Continuous current rating with cable laid in air under specified ambient

temperature for specified maximum conductor temperature Amps.

6. Short circuit capacity

• Current and duration

• Maximum conductor temperature


Page 14of 16

7. Conductor :

• Composition

• Cross section mm2

8. Type of conductor screening

9. Insulation :

• Composition

• Thickness mm

10. Type of insulation screening

11. Inner sheath :

• Material

• Calculated diameter over the stranded cores mm

12. Outer sheath

• Material

• Thickness mm

13. Armour

• Type of armour

• Nominal diameter of cable over inner sheath mm

• Armour thickness/wire diameter mm

14. Overall diameter of the cable mm

15. Recommended minimum bending radius mm

5.2 1100 V Grade Power Cables

1. Manufacturer and cable type

2. Rated voltage

3. Permissible voltage and frequency variation for satisfactory operation

4. Short circuit capacity

• Current and duration Seconds

• Maximum conductor temperature

5. Conductor :
Page 15of 16

• Material

• Cross section mm2

6. Insulation

• Composition

• thickness mm

7. Inner sheath

• Material

• Calculated diameter over the stranded cores mm

8. Outer sheath

• Material

• Thickness mm

9. Armour

• Type of armour

• Nominal diameter of cable over inner sheath mm

• Armour thickness / wire diameter mm

10. Overall diameter of the cable mm

11. Recommended minimum bending radius mm

5.3 1100 V Grade Control Cables


1. Manufacturer and cable type
2. Rated voltage
3. Conductor :
• Material
• Cross Section Sq.mm
• No. and diameter of strands
4. Insulation
• Material composition
• Thickness mm
5. Inner sheath material
6. Outer sheath material
7. Armour
• Type
• Nominal diameter of cable over inner sheath mm
• Armour thickness / wire diameter mm
8. Overall diameter of the cable mm
9. Standard length of cable on each drum
10. Acceptance of Tests Yes/No
6. Lighting Fixtures
Page 16of 16

1. Manufacturer
2. Nominal working voltage V
3. Maximum permissible supply voltage variation for satisfactory operation %
4. Power factor at normal working voltage and frequency
5. Power loss per ballast at nominal working voltage and frequency W
6. Insulation class of ballast winding
7. Light colour of various lamps offered
8. Average total light output per fixture as percentage of combined lamp light
output
9. at nominal working voltage and frequency in still air ambient temperature of
45 0C.
10. Maximum withstand voltage of fixture (50 Hz sine wave test) V (rms)