“W----“ shows information of crane state in correct condition.
Crane capacity is not in defined condition. Register the operating condition correctly.
W0016 Change crane condition to correct condition.
Crane capacity is not in defined condition. Register the operating condition correctly.
W0017 Change crane condition to correct condition.
Stopped due to working area limit (right Cancel work range function, or swing to left.
W0042 swing limit).
Stopped due to working area limit (left swing Cancel work range function, or swing to
W0043 limit). right.
AML back-up battery power is low. This Replace back-up battery by a new one.
W0999 message only appears at power on.
“E1---“ shows communication error between display unit or transmitter and control unit.
If this group error occurs, crane operation stops. But crane operation is possible via the AML
override key.
Wire fault
E1006 Outrigger state transmitter internal error.
Outrigger state transmitter fault.
AML detects data error in data received from Display Unit fault
E1021
Display Unit Wrong connection of communication line.
During ROM sum check, error is detected. Re-write program and data
- AML circuit fault
During RAM check, error is detected. Hardware fault due to external noise.
E3002
AML circuit fault
CPU or DMAC address error
E3003
Hardware fault due to external noise.
Illegal instruction
E3004 Re-write program and data
AML circuit fault
Undefined exception is called.
E3005
Applied voltage to analog detector (5V) is out Wire fault
E3006
of range. Circuit fault
Adjustment data in flash memory is not Hardware fault due to external noise.
correct. AML circuit fault
Note:
E3007
Erase error log.
This message remains until erase error
log operation. Re-write program and
data, or do re-adjustment
Input output handling program(s) do(es) not Hardware fault due to external noise.
E3008
run correctly. AML circuit fault
“E4---“ shows Display Unit error.
If this group error occurs, crane operation stops. Crane operation is basically possible via AML override
key.
Wire fault
Receive timeout error
E4010 Main Unit is updating flash
Cannot receive data from Main Unit
Display unit or Main unit circuit fault
Receive data error
Wire fault
E4011 Cannot receive data from Main Unit.
Display unit or Main unit circuit fault