The purpose of this project is the adaptation of a building that was built for
the Universal Exposition of Seville in the '92 and renovate it for administrative use
by implanting in it a coworking space whilst maintaining the identity of the
property and the legacy inherited from the exhibition.
The distribution of space has been studied only on the ground floor of the
building, however, on the upper floor and in general, the entire building has
been renovated to give a total sensation of space recovery. The upper floor will
be enabled for the possibility of occupying it later for any other use studied.
In order to meet the needs of a coworking space, it has been equipped
with a large open room where the administrative area can accommodate up
to 34 occupants and reprographic machinery, two meeting rooms for the use
of the subscribers or for their rent , A main lobby that connects with all available
areas, warehouse, technical room, toilets and a recreational space. The design
has been devised so that the spaces have great natural lighting for most of the
day using large windows creating interaction between outer and inner space.
La situación actual del sector inmobiliario dada la crisis que en 2.008 sufrió
hace pensar que el futuro de la profesión pueda estar encaminada no solo a
obra nueva como ha sido habitualmente sino más bien a su mantenimiento,
rehabilitación, restauración, adecuaciones, sostenibilidad de edificios y sin
olvidar la obra nueva, en términos menores.
ANÁLISIS HISTÓRICO
El presente proyecto nace de las actuales problemáticas que existen
entorno a la Isla de la Cartuja referidas al abandono y falta de integración con
la ciudad de Sevilla de pabellones e infraestructuras heredadas de la
Exposición Universal ’92.
TELECABINAS
No sólo fue el medio de transporte más utilizado durante el evento con
una afluencia diaria entre 7.889 y 69.385 viajeros, también conectaba el casco
histórico con el recinto protagonizando las mejores vistas de la zona.
Leitner fue la empresa italiana encargada del montaje y diseño del sistema
de telecabinas previa aprobación de la presentación del proyecto en 1.989 y
comenzando a su vez en agosto de ese mismo año para finalizarlas en 1.991. El
coste de la infraestructura fue adjudicado por 726 millones de pesetas.
El diseño de las estaciones fue a cargo del estudio Francisco Ribas junto
con el arquitecto Juan Ovejero Morilla los cuales también le fueron
encomendadas las tareas de diseño de las estaciones del monorraíl.
Tras los pasos citados anteriormente se realizó una visita al lugar del
inmueble para recopilar datos sobre el entorno y el edificio en concreto con la
toma de datos y fotografías útiles en el desarrollo posterior. La actividad
también estuvo complementada por herramientas informáticas como vistas
desde satélites que no pueden obtenerse desde pie de campo.
Uno de los objetivos propuestos que causó mayor interés personal que se
ha visto realizado ha sido el aprendizaje y uso de la herramienta informática
Revit el cual se consideró para la realización del proyecto una buena opción
para poder introducirse en la aplicación.
1.1. Promotor
1.6. Antecedentes
Los pórticos están formados por pilares de acero HEB-180 y vigas BOYD-480
formadas con IPN-320, siendo unidos con vigas de atado con perfiles BOYD-300
de IPN-200, según la documentación consultada.
La formación del forjado está realizada con perfiles UPN-200 en su
perímetro y chapa colaborante de 8.5 cm de espesor, mallazo de 20x30 y
capa de compresión de 3 cm.
2.6. Servidumbres
Contarán con dos salas de reuniones privadas para su alquiler o uso de los
integrantes para realizar exposiciones, talleres, entrevistas o cualquier tipo de
eventos. Próxima a la entrada hay dos locales, uno como local técnico donde
se ubican los servicios de telecomunicación y alimentación de seguridad y otro
para el almacenaje de documentos, etc.
Sistema envolvente
Fachada
Cerramiento
Capas
1.- Cámara de aire sin ventilar: 30 cm
2.- Lana mineral Arena Master “ISOVER”: 5 cm
3.- Falso techo continuo liso “PLACO” de placas de yeso laminado: 2.5 cm
4.- Pintura plástica sobre paramentos interiores de yeso o escayola
HE 1: Limitación de demanda energética
Uc refrigeración: 0.23 W/(m²· K)
Uc calefacción: 0.23 W/(m²· K)
HR: Protección frente al ruido
Masa superficial: 426.91 kg/m²
Masa superficial del elemento base: 389.86 kg/m²
Caracterización acústica por ensayo, Rw (C; Ctr): 39.0 (-1; -7) dB
Referencia al ensayo: C.6.9 (CEC)
Mejora del índice global de reducción acústica, devida al techo suspendido,
∆R: 7 dB
HS 1: Protección frente a la humedad
Tipo de cubierta: Transitable, peatonal, con solado fijo.
Tipo de impermeabilización: Material bituminoso.
Capas
1.- Placa de yeso laminado [PYL] 750 < d < 900: 1.25 cm
2.- Placa de yeso laminado [PYL] 750 < d < 900: 1.25 cm
3.- Lana mineral ISOVER ACUSTILAINE 70: 4.8 cm
4.- Acero inoxidable: 0.6 cm
5.- Lana mineral ISOVER ACUSTILAINE 70: 4.8 cm
6.- Placa de yeso laminado [PYL] 750 < d < 900: 1.25 cm
7.- Placa de yeso laminado [PYL] 750 < d < 900: 1.25 cm
Espesor total: 15.2 cm
HE 1: Limitación de demanda energética
Um: 0.46 W/(m²· K)
HR: Protección frente al ruido
Masa superficial: 94.41 kg/m²
Caracterización acústica por ensayo, Rw (C; Ctr): 33.0 (-1; -3) dB
Referencia del ensayo: Norma
Seguridad en caso de incendio
Resistencia al fuego: EI 180
Capas
1.- Placa de yeso laminado [PYL] 750 < d < 900: 1.5 cm
2.- Lana mineral ISOVER ACUSTILAINE 70: 7 cm
3.- Placa de yeso laminado [PYL] 750 < d < 900: 1.5 cm
Espesor total: 10.0 cm
HE 1: Limitación de demanda energética
Um: 0.47 W/(m²· K)
HR: Protección frente al ruido
Masa superficial: 30.35 kg/m²
Caracterización acústica por ensayo, Rw (C; Ctr): 33.0 (-1; -3) dB
Referencia del ensayo: Norma
Seguridad en caso de incendio
Resistencia al fuego: EI 60
Capas
1.- Placa de yeso laminado [PYL] 750 < d < 900: 1.5 cm
2.- Lana mineral ISOVER ACUSTILAINE 70: 4.8 cm
3.- Placa de yeso laminado [PYL] 750 < d < 900: 1.5 cm
Espesor total: 7.8 cm
HE 1: Limitación de demanda energética
Um: 0.81 W/(m²· K)
HR: Protección frente al ruido
Masa superficial: 27.63 kg/m²
Caracterización acústica por ensayo, Rw (C; Ctr): 33.0 (-1; -3) dB
Referencia del ensayo: Norma
Seguridad en caso de incendio
Resistencia al fuego: EI 60
3.5.5. Telecomunicaciones
Puerta de acceso
Dimensiones Ancho x Alto: 220 x 220 cm nº uds: 1
Sala Coworking
Dimensiones Ancho x Alto: 174 x 234 cm nº uds: 1
Caracterización térmica Transmitancia térmica, U: 2.00 W/(m²·K)
Absortividad, αS: 0.6 (color intermedio)
Caracterización acústica Aislamiento acústico, Rw (C;Ctr): 21 (-1;-2) dB
Resistencia al fuego 2x EI2 45 – C5
Acabado Marco de aluminio – cristalera de vidrio
Sala reuniones
Dimensiones Ancho x Alto: 160 x 220 cm nº uds: 2
Caracterización térmica Transmitancia térmica, U: 2.00 W/(m²·K)
Absortividad, αS: 0.6 (color intermedio)
Caracterización acústica Aislamiento acústico, Rw (C;Ctr): 21 (-1;-2) dB
Resistencia al fuego EI2 45 – C5
Acabado Lacado blanco – tirador de acero inoxidable
Baños
Dimensiones Ancho x Alto: 83 x 203 cm nº uds: 2
Caracterización térmica Transmitancia térmica, U: 2.00 W/(m²·K)
Absortividad, αS: 0.6 (color intermedio)
Caracterización acústica Aislamiento acústico, Rw (C;Ctr): 21 (-1;-2) dB
Resistencia al fuego EI2 45 – C5
Acabado Lacado blanco
Despacho
Dimensiones Ancho x Alto: 91 x 284 cm nº uds: 1
Caracterización térmica Transmitancia térmica, Ug: 1.80 W/(m²·K)
Factor solar, g: 0.39
Se equiparán las salas de reuniones con mesas para éstos fines y mobiliario
para la sala de descanso tales como sofás, mesas comedor, mobiliario
recreativo, etc.
Los equipos ofrecidos serán los destinados a la reprografía tales como dos
equipos plotter, fotocopiadoras multifunción, proyectores y un microondas
para la preparación de comida de los usuarios.
3.8. Acabados
Suelos
Sala de oficinas: gres porcelánico efecto madera de dimensiones 20x120 cm
color Almond según catálogo Travekmore.
Interiores
El acabado general será en pintura Dcora, con una base de imprimación
fijadora Luxens especial para yeso.
Dcora gris suave en la sala de oficinas y Perfect Destello Suave para el resto.
Para los aseos se aplicarán mallas de 30,1x30,1 cm de mosaico color a
escoger. Catálogo Leroy Merlin.
Techos
Techo continuo de placas Pladur Fonic especial para aislamiento acústico de
espesor 13 mm con perfilería según catálogo de gama Pladur. Acabado con
pintura de color blanco.
Exteriores
Mortero monocapa con revestimiento mineral en acabado blanco. Producto
Webber.pral Prisma.
4.1. Técnica
4.2. Urbanística
4.3. Municipal
A) Compartimentación
Tabla 6. Clases de reacción al fuego de los elementos constructivos. Fuente: CTE DB-SI 1. Tabla 4.1
A) Medianería y fachadas
B) Cálculo de la ocupación
Las salidas de recinto, planta o edificio tendrán una señal con el rótulo
“SALIDA”, excepto en edificios de uso Residencial Vivienda y, en otros
usos, cuando se trate de salidas de recintos cuya superficie no exceda de
50 m², sean fácilmente visibles desde todo punto de dichos recintos y los
ocupantes estén familiarizados con el edificio.
En dichos recorridos, junto a las puertas que no sean salida y que puedan
inducir a error en la evacuación debe disponerse la señal con el rótulo
“Sin salida” en lugar fácilmente visible, pero en ningún caso sobre las
hojas de las puertas.
Tabla 14. Clasificación de los suelos según su resbaladicidad. Fuente: CTE DB-SUA 1. Tabla 1.1
Tabla 15. Clase exigible a los suelos según su localización. Fuente. CTE DB-SUA 1. Tabla 1.2
B) Discontinuidades en el pavimento
C) Desniveles
D) Escaleras y rampas
A) Impacto
Elementos practicables
Figura 7. Disposición de puertas laterales a vías de evacuación. Fuente: CTE DB-SUA 2. Figura 1.1
Elementos frágiles
Figura 8. Identificación de áreas con riesgo de impacto. Fuente: CTE DB-SUA 2. Figura 1.2
B) Atrapamiento
A) Aprisionamientos
B) Alumbrado de emergencia
SUA-9 Accesibilidad
Las dimensiones de los vestíbulos serán tales que pueda inscribirse en ellos
una circunferencia de 1,50 metros de diámetro no barrido por las hojas de las
puertas.
La altura del asiento del inodoro estará comprendida entre 0,45 y 0,50
metros y el tipo de abatimiento será vertical.
La distancia mínima entre dos obstáculos entre los que se deba circular,
sean elementos constructivos o de mobiliario, será de 0,80 metros.
Figura 9.. Demanda energética mensual de calefacción y refrigeración. Fuente: autor, CYPE MEP
Figura 10.. Demanda diaria de potencia por superficie. Fuente: autor, CYPE MEP
ª ª
S V renh ΣQocup,s ΣQequip ΣQilum T calef. T refrig.
(m²) (m³)
bve (1/h)
(kWh (kWh (kWh media media
/año) /año) /año) (°C) (°C)
COWORKING (Zona habitable, Perfil: Baja, 16 h)
SALA COWORKING 338.43 860.22 1.00 0.80 3108.1 2331.1 18648.6 20.0 25.0
REUNIONES 1 17.51 44.52 1.00 0.80 160.8 120.6 964.9 20.0 25.0
REUNIONES 2 16.31 41.46 1.00 0.80 149.8 112.4 898.9 20.0 25.0
VESTIBULO 54.10 155.11 1.00 0.80 496.9 372.7 2981.3 20.0 25.0
ZONA DESCANSO 93.22 267.25 1.00 0.80 856.2 642.1 5137.0 20.0 25.0
*
519.58 1368.55 1.00 0.80/0.422 4771.8 3578.8 28630.8 20.0 25.0
Tabla 29.. Solicitaciones interiores de las zonas de cálculo. Fuente: autor, CYPE MEP
donde:
S χ U ∑Qtr ∑Qsol
Tipo (kJ/ (W/ (kWh α I. O. Fsh,o (kWh
(m²) (°) (°)
(m²·K)) (m²·K)) /año) /año)
COWORKING
-23646.4 7388.8
Tabla 30.. Composición constructiva de elementos pesados. Fuente: autor, CYPE MEP
donde:
Ug Uf ∑Qtr ∑Qsol
Tipo S (W/ FF (W/ (kWh ggl α I. O. Fsh,gl Fsh,o (kWh
(m²) (%) (°) (°)
(m²·K)) (m²·K)) /año) /año)
COWORKING
-3449.9 6824.0
Tabla 31.. Composición constructiva de elementos ligeros. Fuente: autor, CYPE MEP
donde:
-5072.5
Tabla 32.. Transmisión de calor de los puentes térmicos. Fuente: autor, CYPE MEP
donde:
HE-2
2 Rendimiento de las instalaciones térmicas
HE-3
3 Eficiencia Energética de las Instalaciones de Iluminación
Tabla 33. Potencia máxima de iluminación. Fuente: CTE DB-HE 3. Tabla 2.2
Tabla 36. Valores de aislamiento acústico a ruido aéreo. Fuente: CTE DB-HR 1. Tabla 2.1
Localidad Sevilla
Altura coronación de edificio ≤ 15 m
Zona eólica A
Tipo terreno IV
Grado de exposición al viento V3
Zona pluviométrica III
Grado de impermeabilidad 3
Tabla 39. Designación de grado de impermeabilidad. Fuente: CTE DB-HS 1
Tabla 40. Soluciones constructivas según grado de impermeabilidad. Fuente: CTE DB-HS 1. Tabla 2.7
C2 Debe utilizarse una hoja principal de espesor alto. Se considera como tal
una fábrica cogida con mortero de:
CUBIERTAS
Los diámetros de las tuberías deben ser los apropiados para transportar los
caudales previsibles en condiciones seguras, establecidos en la tabla 4.1 HS-5 y
formadas con material de PVC.
Las redes de tuberías se han diseñado de tal forma que sean accesibles
para su mantenimiento y reparación, para lo cual deben disponerse a la vista
o alojadas en huecos o patinillos registrables. En caso contrario deben contar
con arquetas o registros.
Se dispondrán sistemas de ventilación adecuados que permitan el
funcionamiento de los cierres hidráulicos y la evacuación de gases mefíticos.
La instalación no debe utilizarse para la evacuación de otro tipo de residuos
que no sean aguas residuales o pluviales.
C) CÁLCULO Y DIMENSIONADO
El cálculo de los bajantes para aguas pluviales se realiza según el punto 4.2
del Documento Básico HS-5. El primer paso a realizar es localizar la zona de
régimen pluviométrico en el que se encuentra Sevilla (según el anexo B), dado
que marca la tabla son valores para un régimen pluviométrico ideal de 100
mm/h.
Figura 11. Mapa de isoyetas y zonas pluviométricas. Fuente: CTE DB-HS 5. Apéndice B. Figura B.1
f= 90/100= 0,9
Tabla 43. Número de sumideros en función de la superficie de cubierta. Fuente: CTE DB-HS 5. Tabla 4.6
Superficie Nº de sumideros
365 4
291 4
Tabla 44. Número de sumideros en proyecto. Fuente: autor
Tabla 45. Diámetro de bajantes de aguas pluviales. Fuente: CTE DB-HS 5. Tabla 4.8
Tabla 47. Diámetro del canalón. Fuente: CTE DB-HS 5. Tabla 4.7
Tabla 49. UDs correspondientes a los distintos aparatos sanitarios. Fuente: CTE DB-HS 5. Tabla 4.1
Los diámetros de conexión entre los aparatos y las arquetas a las que
evacúen quedan establecidos en la tabla 4.3:
Tabla 51. Diámetro de ramales colectores a bajante. Fuente: CTE DB-HS 5. Tabla 4.3
Tabla 53. Diámetro de colectores horizontales según UD y pendiente. Fuente. CTE DB-HS 5. Tabla 4.5
CIUDAD SEVILLA
INTENSIDAD PLUVIOMETRICA (isoyeta tabla B.1)i 90
FACTOR DE CORRECCION (art. 4.2.2) 0,9
PLUVIALES RESIDUALES MIXTA
Sup.
Sup. Sup. equivalente Ø
TRAMO cubierta corregida UD corregida Sup. total % Ø Nominal Adoptado
P-1 182.5 164.25 1 110 125
P-2 365 328.50 2 125 125
P-3 145.5 130.95 1 110 125
P-4 145.5 130.95 1 110 125
BP-1 656 590.40 125 160
CP-1 656 590.40 2 160 160
R-1 16 2 50 125
R-2 52 2 90 125
R-3 10 2 50 110
CM-1 590.40 62 81 671.4 2 160 200
Tabla 54. Tabla de sobredimensionado adoptado. Fuente: autor
Tabla 55. Caudal instantáneo mínimo para cada tipo de aparato. Fuente. CTE DB-HS 4. Tabla 2.1
Añadiremos dos grifos aislados para el riego de la zona exterior, por tanto
el caudal total exigido es:
.
D= = = 34.60 ≈ 40 mm
Figura 13. Esquema de instalación para un usuario. Fuente: Normas particulares ENDESA. Capítulo II
• 3% en circuitos de alumbrado
• 5% en circuitos de fuerza
Nota: los equipos informáticos irán conectados a las tomas rojas (red limpia)
ante una posible ampliación de suministro, instalando un equipo SAI para
evitar la pérdida de información.
FÓRMULAS UTILIZADAS
!
Monofásico = . . (%) =
& # ²
!
Trifásico = . . (%) =
√% & # ²
Siendo:
PREVISIÓN DE CARGAS
Figura 15. Carga correspondiente a locales comerciales y oficinas. Fuente: REBT ITC-10
ACOMETIDA
Figura 17. Sección mínima del neutro. Fuente: REBT ITC BT-07. Tabla 1
Figura 18. Intensidad máxima admisible, conduc. cobre enterrados. Fuente: REBT ITC BT-07. Tabla 5
Figura 19. Diámetros mínimos de tubos de protección. Fuente: REBT ITC BT-21. Tabla 9
INSTALACIÓN INTERIOR
Figura 20. Intensidades máx. admisibles según método de instalación. Fuente: REBT ITC BT-19. Tabla 1
Fuerza
Sala Coworking (C1) 3.450 1 15,00 41 5 11,5 1 - A2 2,5 1,91 2,5 21 3,82% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Sala Coworking (C2) 3.450 1 15,00 28 5 11,5 1 - A2 2,5 1,30 2,5 21 2,61% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Reprografría (C3) 3.620 1 15,74 21 5 11,5 1 - A2 2,5 1,03 2,5 21 2,05% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Vestíbulo (C4) 3.450 1 15,00 9 5 11,5 1 - A2 2,5 0,42 2,5 21 0,84% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Sala de reuniones (C5) 3.450 1 15,00 15 5 11,5 1 - A2 2,5 0,70 2,5 21 1,40% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Despacho (C6) 3.450 1 15,00 7 5 11,5 1 - A2 2,5 0,33 2,5 21 0,65% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Aseos (C7) 3.450 1 15,00 13 5 11,5 1 - A2 2,5 0,61 2,5 21 1,21% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Local técnico / Almacén (C8) 3.450 1 15,00 10 5 11,5 1 - A2 2,5 0,47 2,5 21 0,93% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Sala de descanso (C9) 3.450 1 15,00 24 5 11,5 1 - A2 2,5 1,12 2,5 21 2,24% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
S.A.I.
Puestos de trabajo 1-2 (S1) 3.200 1 13,91 20 5 11,5 1 - A2 2,5 0,86 2,5 21 1,73% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
84
Puestos de trabajo 3-4 (S2) 3.200 1 13,91 28 5 11,5 1 - A2 2,5 1,21 2,5 21 2,42% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Puestos de trabajo 5-6 (S3) 3.200 1 13,91 35 5 11,5 1 - A2 2,5 1,51 2,5 21 3,02% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Puestos de trabajo 7-8 (S4) 3.200 1 13,91 42 5 11,5 1 - A2 2,5 1,81 2,5 21 3,63% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Mostrador (S5) 800 1 3,48 6 5 11,5 1 - A2 2,5 0,06 2,5 21 0,13% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
RACK (S6) 30 1 0,13 8 5 11,5 1 - A2 2,5 0,00 2,5 21 0,01% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Climatización
Recup. entálpico (AA1) 246 1 1,07 20 5 11,5 1 - A2 2,5 0,07 2,5 21 0,13% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Unidad interior 1 (AA2) 1.650 1 7,17 20 5 11,5 1 - A2 2,5 0,45 2,5 21 0,89% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Unidad interior 2 (AA3) 261 1 1,13 20 5 11,5 1 - A2 2,5 0,07 2,5 21 0,14% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Casette 1 (AA4) 840 1 3,65 20 5 11,5 1 - A2 2,5 0,23 2,5 21 0,45% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Casette 2 (AA5) 2.260 1 9,83 20 5 11,5 1 - A2 2,5 0,61 2,5 21 1,22% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Casette 3 (AA6) 2.260 1 9,83 20 5 11,5 1 - A2 2,5 0,61 2,5 21 1,22% Cu 3x2,5 (XLPE) 450/750v. II x 16A.
Estancias BAT
Sala descanso 1 TB + RDSI, 1 TLCA
Sala coworking 1 TB + RDSI
Vestíbulo 1 TB + RDSI, 1 TLCA
Salas de reuniones 1 TB + RDSI, 1 TLCA
Despacho 1 TB + RDSI
Tabla 65. Bases de Acceso Terminal instaladas. Fuente: Reglamento ICT2
Las instalaciones térmicas del edificio objeto del presente proyecto han
sido diseñadas y calculadas de forma que:
Se obtiene una calidad térmica del ambiente y una calidad del aire
interior que son aceptables para los usuarios sin que se produzca
menoscabo de la calidad acústica del ambiente, cumpliendo la
exigencia de bienestar e higiene.
Parámetros Límite
Temperatura operativa en verano (°C) 23 ≤ T ≤ 25
Humedad relativa en verano (%) 45 ≤ HR ≤ 60
Temperatura operativa en invierno (°C) 21 ≤ T ≤ 23
Humedad relativa en invierno (%) 40 ≤ HR ≤ 50
Velocidad media admisible con difusión por mezcla (m/s) V ≤ 0.14
Tabla 66. Límites de calidad del ambiente. Fuente: CYPE MEP
Clases de filtración:
Referencia Categoría
Despacho AE 1
Oficinas AE 1
Sala de descanso AE 1
Sala de reuniones AE 1
Vestíbulo de entrada AE 1
Tabla 70. Categoría de aire de extracción. Fuente: CYPE MEP
%AD: Porcentaje de ahorro de la demanda energética conjunta de calefacción y refrigeración respecto al edificio de
referencia.
%AD,exigido: Porcentaje de ahorro mínimo de la demanda energética conjunta de calefacción y refrigeración respecto al
edificio de referencia para edificios de otros usos en zona climática de verano 4 y Media carga de las fuentes
internas del edificio, (tabla 2.2, CTE DB
D HE 1), 20.0 %.
DG,obj: Demanda energética conjunta de calefacción y refrigeración del edificio objeto, calculada como suma
ponderada de las demandas de calefacción y refrigeración, según DG = DC + 0.7 · DR, en territorio
peninsular, kWh/(m²·año).
DG,ref: Demanda energética conjunta de calefacción y refrigeración del edificio de referencia, calculada en las
mismas condiciones de cálculo que el edificio objeto, obtenido conforme a las reglas establecidas en el
Apéndice D de CTE DB HE 1 y el documento 'Condiciones
'Condiciones de aceptación de programas alternativos a
LIDER/CALENER'.
CONJUNTO
Subtotales Carga interna Ventilación Potencia térmica
Recinto Máxima
Estructural Sensible interior Total interior Sensible Total Caudal Sensible Carga total Por superficie Sensible
simultánea
(W) (W) (W) (W) (W) (m³/h) (W) (W) (W/m²) (W)
(W)
Vestíbulo 1690.63 1414.06 1837.39 3197.83 3621.16 270.52 972.73 1412.82 93.04 4170.56 5033.98
Zona
1900.37 3587.74 4252.97 5652.75 6317.99 466.12 1676.08 2434.39 93.89 7328.84 8752.38
descanso
Total 736.6 Carga total simultánea 13786.4
DESPACHO
Subtotales Carga interna Ventilación Potencia térmica
REUNIÓN 1
Subtotales Carga interna Ventilación Potencia térmica
REUNIÓN 2
Subtotales Carga interna Ventilación Potencia térmica
SALA COWORKING
Subtotales Carga interna Ventilación Potencia térmica
Recinto Máxima
Estructural Sensible interior Total interior Sensible Total Caudal Sensible Carga total Por superficie Sensible
(W) (W) (W)
simultánea
(W) (W) (m³/h) (W) (W) (W/m²) (W)
(W)
Sala
3007.26 12896.81 15194.90 16381.19 18679.28 1692.13 6084.57 8837.39 81.31 22465.76 27516.66
Coworking
Total 1692.1 Carga total simultánea 27516.7
Calefacción
CONJUNTO
Ventilación Potencia
Carga interna sensible
Recinto Caudal Carga total Por superficie Máxima simultánea
(W)
(m³/h) (W) (W/m²) (W)
Vestíbulo 2288.10 270.52 1608.87 72.03 3896.97
Zona descanso 2794.92 466.12 2772.20 59.72 5567.11
Total 736.6 Carga total simultánea 9464.1
DESPACHO
Ventilación Potencia
Carga interna sensible
Recinto Caudal Carga total Por superficie Máxima simultánea
(W)
(m³/h) (W) (W/m²) (W)
Despacho 726.35 52.19 310.41 99.32 1036.76
Total 52.2 Carga total simultánea 1036.8
REUNIÓN 2
Ventilación Potencia
Carga interna sensible
Recinto Caudal Carga total Por superficie Máxima simultánea
(W)
(m³/h) (W) (W/m²) (W)
Reunión 2 407.62 367.02 2182.81 158.80 2590.44
Total 367.0 Carga total simultánea 2590.4
SALA COWORKING
Ventilación Potencia
Carga interna sensible
Recinto Caudal Carga total Por superficie Máxima simultánea
(W)
(m³/h) (W) (W/m²) (W)
Sala Coworking 8109.24 1692.13 10063.72 53.70 18172.96
Total 1692.1 Carga total simultánea 18173.0
Tabla 72. Cálculos de calefacción. Fuente: CYPE MEP
Refrigeración
Potencia por superficie Potencia total
Conjunto
(W/m²) (W)
CONJUNTO 93.6 13786.4
DESPACHO 191.3 1989.0
REUNIÓN 1 246.3 4310.0
REUNIÓN 2 212.4 3462.7
SALA COWORKING 81.3 27516.7
TOTAL 51064.8
Tabla 73. Resumen de potencia de refrigeración. Fuente: CYPE MEP
Calefacción
Potencia por superficie Potencia total
Conjunto
(W/m²) (W)
CONJUNTO 64.3 9464.1
DESPACHO 99.7 1036.8
REUNIÓN 1 171.5 3001.6
REUNIÓN 2 158.9 2590.4
SALA COWORKING 53.7 18173.0
TOTAL 34265.9
Tabla 74. Resumen de potencia de calefacción. Fuente: CYPE MEP
Caudal ∆P Ε
Tipo N
(m³/h) (Pa) (%)
Tipo 3 3000 400.0 100.0 95.0
Abreviaturas utilizadas
Tipo Tipo de recuperador ∆P Presion disponible en el recuperador (Pa)
Número de horas de funcionamiento de la
N instalación
Ε Eficiencia en calor sensible (%)
Equipos Referencia
Unidad interior de aire acondicionado para sistema VRV (Volumen de Refrigerante
Variable), con distribución por conducto rectangular, alta presión, para gas R-410A,
alimentación monofásica (230V/50Hz), modelo FXMQ250MA "DAIKIN", potencia
frigorífica nominal 28 kW (temperatura de bulbo seco del aire interior 27°C,
temperatura de bulbo húmedo del aire interior 19°C, temperatura de bulbo seco del
aire exterior 35°C), potencia calorífica nominal 31,5 kW (temperatura de bulbo seco
del aire interior 20°C, temperatura de bulbo seco del aire exterior 7°C), consumo
Tipo 1 eléctrico nominal en refrigeración 1465 W, consumo eléctrico nominal en calefacción
1650 W, presión sonora a velocidad baja 45 dBA, caudal de aire a velocidad alta 72
m³/min, de 470x1380x1100 mm, peso 137 kg, con ventilador de dos velocidades y
presión estática disponible de 147 a 270 Pa, válvula de expansión electrónica,
bomba de drenaje, aspiración de aire trasera o inferior, bloque de terminales F1-F2
para cable de 2 hilos de transmisión y control (bus D-III Net) a unidad exterior,
control por microprocesador y filtro de aire de succión, con juego de controlador
remoto inalámbrico formado por receptor y mando por infrarrojos, modelo BRC4C62
Unidad interior de aire acondicionado para sistema VRV (Volumen de Refrigerante
Variable), con distribución por conducto rectangular, para gas R-410A, alimentación
monofásica (230V/50Hz), modelo FXSQ140P "DAIKIN", potencia frigorífica nominal
16 kW (temperatura de bulbo seco del aire interior 27°C, temperatura de bulbo
húmedo del aire interior 19°C, temperatura de bulbo seco del aire exterior 35°C),
potencia calorífica nominal 18 kW (temperatura de bulbo seco del aire interior 20°C,
temperatura de bulbo seco del aire exterior 7°C), consumo eléctrico nominal en
refrigeración 261 W, consumo eléctrico nominal en calefacción 249 W, presión
Tipo 2 sonora a velocidad baja 35 dBA, caudal de aire a velocidad alta 46 m³/min, de
300x1400x700 mm, peso 52 kg, con ventilador de tres velocidades con regulación
Inverter (la presión estática del ventilador se ajusta automáticamente a la pérdida
de carga real en los conductos) y presión estática disponible de 50 a 140 Pa, válvula
de expansión electrónica, bomba de drenaje, aspiración de aire trasera o inferior,
bloque de terminales F1-F2 para cable de 2 hilos de transmisión y control (bus D-III
Net) a unidad exterior, control por microprocesador y filtro de aire de succión, con
juego de controlador remoto inalámbrico formado por receptor y mando por
infrarrojos, modelo BRC4C65
Equipos Referencia
Equipo de aire acondicionado, sistema aire-aire split 1x1, de cassette, de 600x600
mm, para gas R-410A, bomba de calor, con tecnología Hyper Inverter, gama semi-
industrial (PAC), alimentación monofásica (230V/50Hz), modelo FDTC25VFNX
"MITSUBISHI HEAVY INDUSTRIES", potencia frigorífica nominal 2,55 kW
(temperatura de bulbo seco en el interior 27°C, temperatura de bulbo húmedo en el
interior 19°C, temperatura de bulbo seco en el exterior 35°C, temperatura de bulbo
húmedo en el exterior 24°C), potencia calorífica nominal 3,45 kW (temperatura de
bulbo seco en el interior 20°C, temperatura de bulbo húmedo en el exterior 6°C),
Tipo 1
SEER = 6,1 (clase A+), SCOP = 4,2 (clase A), EER = 4,25 (clase A), COP = 4,11
(clase A), formado por una unidad interior FDTC25VF, de 248x570x570 mm con
panel de 35x700x700 mm, nivel sonoro (velocidad baja) 29 dBA, caudal de aire
(velocidad alta) 600 m³/h, con filtro, bomba de drenaje y control por cable, modelo
RC-E5, y una unidad exterior SRC25ZMX, con compresor de tipo rotativo, de
595x780x290 mm, nivel sonoro 47 dBA y caudal de aire 1770 m³/h, con control de
condensación y posibilidad de integración en un sistema domótico o control Wi-Fi a
través de un interface (no incluido en este precio)
Unidad exterior de aire acondicionado, sistema aire-aire multi-split, para gas R-
410A, bomba de calor, gama doméstica (RAC), alimentación monofásica
(230V/50Hz), modelo SCM80ZM "MITSUBISHI HEAVY INDUSTRIES", potencia
frigorífica nominal 8 kW (temperatura de bulbo seco 35°C, temperatura de bulbo
Tipo 2 húmedo 24°C), potencia calorífica nominal 9,3 kW (temperatura de bulbo húmedo
6°C), con compresor con tecnología Inverter, de 750x880x340 mm, nivel sonoro 54
dBA y caudal de aire 3360 m³/h, con control de condensación y posibilidad de
integración en un sistema domótico o control Wi-Fi a través de un interface (no
incluido en este precio)
Unidad interior de aire acondicionado, de cassette, de 600x600 mm, sistema aire-
aire multi-split, para gas R-410A, bomba de calor, gama doméstica (RAC),
alimentación monofásica (230V/50Hz), modelo FDTC60VF "MITSUBISHI HEAVY
INDUSTRIES", potencia frigorífica nominal 6 kW (temperatura de bulbo seco 27°C,
temperatura de bulbo húmedo 19°C), potencia calorífica nominal 6,8 kW
Tipo 3
(temperatura de bulbo seco 20°C), de 248x570x570 mm con panel de 35x700x700
mm, nivel sonoro (velocidad baja) 30 dBA, caudal de aire (velocidad alta) 810 m³/h,
con filtro, bomba de drenaje, control por cable, modelo RC-E5 y posibilidad de
integración en un sistema domótico o control Wi-Fi a través de un interface (no
incluido en este precio)
Tabla 77. Equipos de expansión directa. Fuente: CYPE MEP
A2-Planta baja N3-Planta baja 1800.0 400x300 4.5 2.84 9.13 77.04 9.19
A2-Planta baja N3-Planta baja 1500.0 300x300 4.9 4.49 9.13 80.73 5.50
A2-Planta baja N3-Planta baja 1200.0 300x300 3.9 5.32 9.13 83.63 2.59
A2-Planta baja N3-Planta baja 900.0 300x300 3.0 4.55 9.13 85.11 1.12
A2-Planta baja N3-Planta baja 600.0 300x300 2.0 5.58 9.13 85.98 0.25
A2-Planta baja N3-Planta baja 300.0 300x300 1.0 5.49 9.13 86.22
A2-Planta baja N3-Planta baja 300x300 2.74 77.09
A2-Planta baja A4-Planta baja 2550.0 5.6 0.48 23.80 24.23
Abreviaturas utilizadas
Q Caudal L Longitud
Abreviaturas utilizadas
Φ Diámetro P Potencia sonora
27.02.2017
Altura del local: 3.650 m, Altura de montaje: 2.950 m, Factor Valores en Lux, Escala 1:213
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 5.67 W/m² = 1.33 W/m²/100 lx (Base: 343.12 m²)
102
ESPACIO COWORKING
27.02.2017
Reunión 1 / Resumen
Altura del local: 3.250 m, Altura de montaje: 3.247 m, Factor Valores en Lux, Escala 1:48
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 7.24 W/m² = 1.81 W/m²/100 lx (Base: 17.67 m²)
Reunión 2 / Resumen
Altura del local: 3.250 m, Altura de montaje: 3.247 m, Factor Valores en Lux, Escala 1:43
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 7.94 W/m² = 1.89 W/m²/100 lx (Base: 16.12 m²)
104
27.02.2017
Despacho / Resumen
Altura del local: 3.250 m, Altura de montaje: 3.247 m, Factor Valores en Lux, Escala 1:35
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 6.30 W/m² = 2.27 W/m²/100 lx (Base: 10.16 m²)
Vestíbulo / Resumen
Altura del local: 3.250 m, Factor mantenimiento: 0.80 Valores en Lux, Escala 1:152
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 10.37 W/m² = 2.36 W/m²/100 lx (Base: 55.38 m²)
106
ESPACIO COWORKING
27.02.2017
Altura del local: 3.250 m, Altura de montaje: 3.247 m, Factor Valores en Lux, Escala 1:26
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 9.36 W/m² = 3.69 W/m²/100 lx (Base: 3.42 m²)
ESPACIO COWORKING
27.02.2017
Almacén / Resumen
Altura del local: 3.250 m, Altura de montaje: 3.247 m, Factor Valores en Lux, Escala 1:26
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 5.37 W/m² = 2.63 W/m²/100 lx (Base: 5.95 m²)
108
E
ESPACIO COWORKING
27.02.2017
Altura del local: 2.700 m, Altura de montaje: 2.697 m, Factor Valores en Lux, Escala 1:23
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 4.23 W/m² = 2.05 W/m²/100 lx (Base: 4.25 m²)
ESPACIO COWORKING
27.02.2017
Aseo M / Resumen
Altura del local: 2.700 m, Factor mantenimiento: 0.80 Valores en Lux, Escala 1:51
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 8.07 W/m² = 1.98 W/m²/100 lx (Base: 10.65 m²)
110
ESPACI
ESPACIO COWORKING
27.02.2017
Aseo H / Resumen
Altura del local: 2.700 m, Factor mantenimiento: 0.80 Valores en Lux, Escala 1:51
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 8.67 W/m² = 2.18 W/m²/100 lx (Base: 7.84 m²)
27.02.2017
Altura del local: 2.700 m, Altura de montaje: 2.697 m, Factor Valores en Lux, Escala 1:24
mantenimiento: 0.80
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 14.92 W/m² = 2.52 W/m²/100 lx (Base: 4.29 m²)
112
ESPACIO COWO
ESPACIO COWORKING
27.02.2017
Altura del local: 3.250 m, Factor mantenimiento: 0.80 Valores en Lux, Escala 1:152
E /E
Superficie ρ [%] Em [lx] Emin [lx] Emax [lx] min m
Valor de eficiencia energética: 2.73 W/m² = 1.43 W/m²/100 lx (Base: 95.45 m²)
Decreto 293/2009, de 7 de julio, por el que se aprueba el reglamento que regula las normas para la
accesibilidad en las infraestructuras, el urbanismo, la edificación y el transporte en Andalucía.
BOJA nº 140, de 21 de julio de 2009
Corrección de errores. BOJA nº 219, de 10 de noviembre de 2009
DATOS GENERALES
FICHAS Y TABLAS JUSTIFICATIVAS*
* Orden de 9 de enero de 2012, por la que se aprueban los modelos de fichas y tablas justificativas del Reglamento
que regula las normas para la accesibilidad en las infraestructuras, el urbanismo, la edificación y el transporte en
Andalucía, aprobado por el Decreto 293/2009, de 7 de julio, y las instrucciones para su cumplimentación.
(BOJA núm. 12, de 19 de enero).
Apartados: (Página 2 de 42) ANEXO I
DATOS GENERALES
DOCUMENTACIÓN
FICHA II
TABLA 7
ACTUACIÓN
ADMINISTRATIVO
DOTACIONES NÚMERO
Aforo (número de personas) 125
Número de asientos -
Superficie 614
Accesos 2
Ascensores -
Rampas -
Alojamientos -
Núcleos de aseos 1
Aseos aislados -
Núcleos de duchas -
Duchas aisladas -
Núcleos de vestuarios -
Vestuarios aislados -
Probadores -
Plazas de aparcamientos -
Plantas 1
Puestos de personas con discapacidad (sólo en el supuesto de centros de enseñanza reglada de educación
especial)
LOCALIZACIÓN
AVENIDA CAMINO DE LOS DESCUBRIMIENTOS. SEVILLA.
TITULARIDAD
JUNTA DE ANDALUCÍA.
PERSONA/S PROMOTORA/S
JUNTA DE ANDALUCÍA.
PROYECTISTA/S
RAFAEL RAMÍREZ VITAL.
Apartados: (Página 3 de 42) ANEXO I
OBSERVACIONES
Fdo.:
Apartados: (Página 12 de 42) ANEXO I
Pavimentos de rampas
Material:
Color:
Resbaladicidad:
Pavimentos de escaleras
Material:
Color:
Resbaladicidad:
Se cumplen todas las condiciones de la normativa aplicable relativas a las características de los materiales empleados y la construcción de los
itinerarios accesibles en el edificio. Todos aquellos elementos de equipamiento e instalaciones del edificio (teléfonos, ascensores, escaleras mecánicas...)
cuya fabricación no depende de las personas proyectistas, deberán cumplir las condiciones de diseño que serán comprobadas por la dirección facultativa
de las obras, en su caso, y acreditadas por la empresa fabricante.
No se cumple alguna de las condiciones constructivas, de los materiales o del equipamiento, lo que se justifica en las observaciones de la presente
Ficha justificativa integrada en el proyecto o documentación técnica.
* Orden de 9 de enero de 2012, por la que se aprueban los modelos de fichas y tablas justificativas del Reglamento que regula las normas para la
accesibilidad en las infraestructuras, el urbanismo, la edificación y el transporte en Andalucía, aprobado por el Decreto 293/2009, de 7 de julio, y las
instrucciones para su cumplimentación. (BOJA núm. 12, de 19 de enero).
Ficha II -1-
Apartados: (Página 13 de 42) ANEXO I
El edificio, establecimiento o instalación, de titularidad de las Administraciones Públicas o sus entes instrumentales dispone, al menos,
de un ascensor accesible que comunica todas las plantas de uso público o privado
El edificio, establecimiento o instalación de concurrencia pública y más de una planta dispone de un ascensor accesible que comunica
las zonas de uso público.
Acceso a las distintas plantas El edificio, establecimiento o instalación, sea o no de concurrencia pública, necesita salvar más de dos plantas desde alguna entrada
principal accesible al edificio hasta alguna planta que no sea de ocupación nula, y para ello dispone de ascensor accesible o rampa accesible
que comunica las plantas que no sean de ocupación nula con las de entrada accesible al edificio.
El edificio, establecimiento o instalación, sea o no de concurrencia pública, tiene más de 200 m2 de superficie útil en plantas sin entrada
accesible al edificio, excluida la superficie de zonas de ocupación nula, y para ello dispone de ascensor accesible o rampa accesible que
comunica las plantas que no sean de ocupación nula con las de entrada accesible al edificio
Ficha II -2-
Apartados: (Página 14 de 42) ANEXO I
Los cambios de nivel a zonas de uso y concurrencia pública o a elementos accesibles tales como plazas de aparcamientos accesibles, alojamientos accesibles, plazas
reservadas, etc, cuentan con un medio accesible, rampa o ascensor, alternativo a las escaleras.
NORMATIVA DB -SUA DEC.293/2009 (Rgto) ORDENANZA DOC. TÉCNICA
ESCALERAS (Rgto. art.70, DB-SUA1)
Directriz Recta(2) Recta(2)
Curva o mixta(3) Curva o mixta(3)
Altura salvada por el Uso general ≤ 3,20 m --
tramo Uso público (1) o sin alternativa de ascensor ≤ 2,25 m --
Número mínimo de peldaños por tramo ≥3 Según DB-SUA
Huella ≥ 0,28 m Según DB-SUA
Ficha II -3-
Apartados: (Página 15 de 42) ANEXO I
Altura de zócalo o elemento protector lateral en bordes libres (*) ≥ 0,10 m ≥ 0,10 m
En rampas de ancho ≥ 4,00 m se disponen barandillas centrales con doble pasamanos.
( *) En desniveles ≥ 0,185 m con pendiente ≥ 6%, pasamanos a ambos lados y continuo incluyendo mesetas y un zócalo o elemento de protección lateral
El pasamanos es firme y fácil de asir, está separado del paramento al menos 0,04 m y su sistema de sujeción no interfiere el paso continuo de la mano. Se disponen de
pasamanos continuos a ambos lados y diferenciados cromáticamente de las superficies del entorno.
Las rampas que salvan una altura ≥ 0,55 m. disponen de barandillas o antepechos coronados por pasamanos
TAPICES RODANTES Y ESCALERAS MECÁNICAS (Rgto. Art. 71, Art.73)
Luz libre -- ≥ 1,00 m 1.00 m
Pendiente -- ≤ 12 % CUMPLE
Tapiz rodante Prolongación de pasamanos en
desembarques -- 0,45 m CUMPLE
Altura de los pasamanos. -- ≤ 0,90 m CUMPLE
Luz libre -- ≥ 1,00 m
Anchura en el embarque y en el
desembarque -- ≥ 1,20 m
Ficha II -4-
Apartados: (Página 16 de 42) ANEXO I
Espacio para personas usuarias de Aproximación frontal ≥ (0,80 x 1,20) m ≥ (0,90 x 1,20) m
silla de ruedas ≥ (0,80 x 1,50) m ≥ (0,90 x 1,50) m
Aproximación lateral
Plaza para personas con discapacidad auditiva (más de 50 asientos y actividad con componente auditivo). 1 cada 50 plazas o fracción. Disponen de sistema de mejora acústica
mediante bucle de inducción magnética u otro dispositivo similar.
En escenarios, estrados, etc., la diferencia de cotas entre la sala y la tarima (en su caso) se resuelve con escalera y rampa o ayuda técnica.
Ficha II -5-
Apartados: (Página 17 de 42) ANEXO I
En el interior debe disponer de avisador luminoso y acústico para casos de emergencia cuando sea obligatoria la instalación de sistema de alarma. El avisador estará conectado
con sistema de alarma.
En zonas de uso público, debe contar con un dispositivo en el interior fácilmente accesible, mediante el cual se pueda transmitir una llamada de asistencia perceptible desde un
punto de control que permita a la persona usuaria verificar que su llamada ha sido recibida, o perceptible desde un paso frecuente de personas.
VESTUARIOS, DUCHAS Y PROBADORES (Rgto. Art. 78, DB-SUA 9 y Anejo A)
Vestuarios 1 de cada 10 o fracción Al menos uno
Ficha II -6-
Apartados: (Página 18 de 42) ANEXO I
Si los alojamientos disponen de aseo, será accesible. Si no disponen de él, existirá un itinerario accesible hasta el aseo accesible exterior al alojamiento.
Instalaciones complementarias:
Sistema de alarma que transmite señales visuales visibles desde todo punto interior, incluido el aseo
Avisador luminoso de llamada complementario al timbre
Dispositivo luminoso y acústico para casos de emergencia (desde fuera)
Bucle de inducción magnética
Ficha II -7-
Apartados: (Página 19 de 42) ANEXO I
Se disponen zonas de descanso para distancias en el mismo nivel ≥ 50,00 m, o cuando pueda darse una situación de espera.
Existen puertas de apertura automática con dispositivos sensibles de barrido vertical, provistas de un mecanismo de minoración de velocidad que no
supere 0,50 m/s, dispositivos sensibles que abran en caso de atrapamiento y mecanismo manual de parada del sistema de apertura y cierre. Dispone
de mecanismo manual de parada de sistema de apertura.
El espacio reservado para personas usuarias de silla de ruedas es horizontal y a nivel con los asientos, está integrado con el resto de asientos y
señalizado.
Las condiciones de los espacios reservados:
Ficha II -8-
Apartados: (Página 20 de 42) ANEXO I
OBSERVACIONES
Ficha II -9-
6.8. GESTIÓN DE RESIDUOS
2. Agentes intervinientes
Gestor de residuos
Es la persona física o jurídica, o entidad pública o privada, que realice
cualquiera de las operaciones que componen la recogida, el
almacenamiento, el transporte, la valorización y la eliminación de los residuos,
incluida la vigilancia de estas operaciones y la de los vertederos, así como su
restauración o gestión ambiental de los residuos, con independencia de
ostentar la condición de productor de los mismos. Éste será designado por el
Productor de los residuos (Promotor) con anterioridad al comienzo de las obras.
Obligaciones
Gestor de residuos
Además de las recogidas en la legislación específica sobre residuos, el
gestor de residuos de construcción y demolición cumplirá con las siguientes
obligaciones:
- En el supuesto de actividades de gestión sometidas a autorización por la
legislación de residuos, llevar un registro en el que, como mínimo, figure la
cantidad de residuos gestionados, expresada en toneladas y en metros
cúbicos, el tipo de residuos, codificados con arreglo a la lista europea de
residuos publicada por Orden MAM/304/2002, de 8 de febrero, o norma que la
sustituya, la identificación del productor, del poseedor y de la obra de donde
proceden, o del gestor, cuando procedan de otra operación anterior de
gestión, el método de gestión aplicado, así como las cantidades, en toneladas
y en metros cúbicos, y destinos de los productos y residuos resultantes de la
actividad.
- Poner a disposición de las administraciones públicas competentes, a
petición de las mismas, la información contenida en el registro mencionado en
el punto anterior. La información referida a cada año natural deberá
mantenerse durante los cinco años siguientes.
- Extender al poseedor o al gestor que le entregue residuos de
construcción y demolición, en los términos recogidos en este real decreto, los
certificados acreditativos de la gestión de los residuos recibidos, especificando
el productor y, en su caso, el número de licencia de la obra de procedencia.
Cuando se trate de un gestor que lleve a cabo una operación exclusivamente
de recogida, almacenamiento, transferencia o transporte, deberá además
transmitir al poseedor o al gestor que le entregó los residuos, los certificados de
la operación de valorización o de eliminación subsiguiente a que fueron
destinados los residuos.
- En el supuesto de que carezca de autorización para gestionar residuos
peligrosos, deberá disponer de un procedimiento de admisión de residuos en
la instalación que asegure que, previamente al proceso de tratamiento, se
detectarán y se separarán, almacenarán adecuadamente y derivarán a
gestores autorizados de residuos peligrosos aquellos que tengan este carácter
y puedan llegar a la instalación mezclados con residuos no peligrosos de
construcción y demolición. Esta obligación se entenderá sin perjuicio de las
responsabilidades en que pueda incurrir el productor, el poseedor o, en su
caso, el gestor precedente que haya enviado dichos residuos a la instalación.
Modificada por:
Modificación de diversos reglamentos del área de medio ambiente para
su adaptación a la Ley 17/2009, de 23 de noviembre, sobre el libre acceso
a las actividades de servicios y su ejercicio, y a la Ley 25/2009, de 22 de
diciembre, de modificación de diversas leyes para su adaptación a la Ley
de libre acceso a actividades de servicios y su ejercicio.
Real Decreto 367/2010, de 26 de marzo, del Ministerio de la Presidencia.
B.O.E.: 27 de marzo de 2010
Modificado por:
Regulación de la producción y gestión de los residuos de construcción y
demolición
Real Decreto 105/2008, de 1 de febrero, del Ministerio de la Presidencia.
B.O.E.: 13 de febrero de 2008
Modificado por:
Modificación de diversos reglamentos del área de medio ambiente para
su adaptación a la Ley 17/2009, de 23 de noviembre, sobre el libre acceso
a las actividades de servicios y su ejercicio, y a la Ley 25/2009, de 22 de
diciembre, de modificación de diversas leyes para su adaptación a la Ley
de libre acceso a actividades de servicios y su ejercicio
Real Decreto 367/2010, de 26 de marzo, del Ministerio de la Presidencia.
B.O.E.: 27 de marzo de 2010
Desarrollado por:
Formulación del Plan de gestión de residuos peligrosos de Andalucía
Acuerdo de 17 de junio de 1997, de la Consejería de Medio Ambiente de
la Junta de Andalucía.
B.O.J.A.: 5 de julio de 1997
Desarrollado por:
Plan director territorial de gestión de residuos urbanos de Andalucía
Decreto 218/1999, de 26 de octubre, de la Consejería de Medio Ambiente
de la Junta de Andalucía.
B.O.J.A.: 18 de noviembre de 1999
Desarrollado por:
Revisión del plan de gestión de residuos peligrosos de Andalucía
Decreto 99/2004, de 9 de marzo, de la Consejería de Medio Ambiente de
la Junta de Andalucía.
B.O.J.A.: 1 de abril de 2004
RCD de Nivel I
RCD de Nivel II
Madera
Papel y cartón
Plástico
Vidrio
Tabla 3. Tratamiento adoptado y destino para los residuos generados. Fuente: autor
Hormigón No obligatoria
Vidrio No obligatoria
Plástico No obligatoria
Los contenedores deberán estar pintados con colores vivos, que sean
visibles durante la noche, y deben contar con una banda de material
reflectante de, al menos, 15 centímetros a lo largo de todo su perímetro,
figurando de forma clara y legible la siguiente información:
- Razón social.
- Código de Identificación Fiscal (C.I.F.).
- Número de teléfono del titular del contenedor/envase.
- Número de inscripción en el Registro de Transportistas de Residuos del
titular del contenedor.
Figura 1. Entorno.
Figura 6. Interiores.
Figura 35. Vista noctura vestíbulo principal, accesos a sala coworking y depachos.
DOCUMENTACIÓN ORIGINAL
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
Acceso escaleras 1 5,81 2,89 16,79
Acceso mecánicas 1 3,12 7,00 21,84
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 02 SANEAMIENTO
02.01 m COLECTOR COLGADO DE PVC DIÁM. 125 mm
Colector colgado de PVC, presión 4 kg/cm2, de 125 mm de diámetro nominal, incluso p.p. de pie-
zas especiales, abrazaderas, contratubo,pequeño material y ayudas de albañilería; construido según
CTE. Medida la longitud ejecutada.
Conex iones 4 3,47 13,88
P1 1 14,40 14,40
P2 1 10,70 10,70
P3 1 6,85 6,85
P4 1 2,10 2,10
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 03 ESTRUCTURAS
03.01 m² FORJADO CHAPA COLABORANTE 10 cm ESPESOR
Forjado mediante chapa colaborante de 10 cm de espesor y 0,75 mm de espesor de chapa, realiza-
do con hormigón armado tipo HA-25/P/20/IIa, consistencia plástica y tamaño máximo del árido 20
mm, complementarias con acero B 500 S, incluso p.p. de macizado de apoyos, encofrados comple-
mentarios, apeos, desencofrado, vibrado y curado; construido según EHE, NCSR-02 y CTE. Me-
dida la superficie de fuera a fuera deduciendo huecos mayores de 1 m2.
Zona superior 1 17,97 10,57 189,94
1 12,44 13,57 168,81
Zona inferior 1 14,72 9,22 135,72
1 5,24 13,57 71,11
1 1,95 3,25 6,34
Acceso escaleras 1 5,81 2,89 16,79
Acceso mecánicas 1 3,12 7,00 21,84
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 04 ALBAÑILERÍA
04.01 m2 CERRAM. 2 HOJAS FAB. BLOQ. HORM. Y LAD. H/D 20+7 cm
Cerramiento con dos hojas, realizado con fábrica de bloques de hormigón de 40x20x12 cm la hoja
exterior, cámara de aire de 5 cm, y tabicón de ladrillo H/D de 7 cm de espesor la hoja interior, recibi-
dos con mortero M5 de cemento CEM II/A-L 32,5 N. Medida deduciendo huecos.
NORTE
1 17,53 4,25 74,50
1 1,50 4,25 6,38
1 12,46 4,25 52,96
2 1,50 4,25 12,75
1 7,30 4,10 29,93
1 12,00 3,25 39,00
SUR
1 17,53 4,25 74,50
1 1,50 4,25 6,38
1 19,95 4,25 84,79
1 2,07 3,83 7,93
1 4,80 3,64 17,47
1 0,41 3,45 1,41
1 10,47 3,25 34,03
OESTE
1 7,26 4,25 30,86
1 1,66 4,25 7,06
ESTE
1 1,78 3,25 5,79
1 5,61 3,25 18,23
1 4,95 3,25 16,09
1 0,64 3,25 2,08
P1 1 -1,80 2,10 -3,78
PE 1 -2,20 2,20 -4,84
V1 1 -3,75 0,40 -1,50
CRISTALERAS 1 1,00
Norte 1 -34,98 2,85 -99,69
1 -1,25 2,17 -2,71
Sur 1 -34,98 2,85 -99,69
1 -1,25 2,17 -2,71
1 -6,80 0,30 -2,04
Oeste 1 -7,18 2,85 -20,46
1 -1,58 2,85 -4,50
Este 1 -7,00 2,17 -15,19
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 05 CUBIERTAS
05.01 m2 FALDÓN AZ. TRANS. S/HORMIG. 10 cm 1 MEMB. BETÚN
Faldón de azotea transitable formado por: lana mineral soldable de 4 cm de espesor, impermeabiliza-
ción asfáltica monocapa 0.36 cm de espesor medio, capa de mortero de regulación espesor 3 cm y
solado con baldosa de gres porcelánico de 10x20 cm recibido con mortero bastardo, colocado con
juntas de 8 a10 mm, incluso enlechado, con pasta de cal, avitolado de juntas y p.p. de solapes. Me-
dido en proyección horizontal deduciendo huecos mayores de 1 m2.
Zona superior 1 17,97 10,57 189,94
1 12,44 13,57 168,81
Zona inferior 1 14,72 9,22 135,72
1 5,24 13,57 71,11
1 1,95 3,25 6,34
Acceso escaleras 1 5,81 2,89 16,79
Acceso mecánicas 1 3,12 7,00 21,84
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 06 INSTALACIONES
SUBCAPÍTULO 06.01 CLIMATIZACIÓN
06.01.01 m2 CONDUCTO RECTANG. DISTR. AIRE AC. GALV. 1,0 mm L. MÁX. 1,3 m
Conducto rectangular, para distribución de aire, construido con chapa de acero galvanizado de1 mm
de espesor plegada en los extremos, diagonales matrizadas, para una dimensión máxima del lado
mayor de la sección de 1,30 m unión de tramos, a 1 m como máximo, con bridas de ángulo galvani-
zado de 30x30x3 mm, incluso elementos para soporte, junta y cuelgue y ayudas de albañilería. Me-
dida la superficie desarrollada, las curvas por el radio mayor y las reducciones por su sección ma-
yor.
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 07 AISLAMIENTOS
07.01 m2 AISLAMIENTO PAREDES PANEL RÍGIDO LANA MINERAL 30 mm
Aislamiento de paredes con panel rígido delana mineral, de 30 mm de espesor y 70 kg/m3 de densi-
dad, colocado sobre superficies planas, incluso corte y colocación; según CTE . Medida la superfi-
cie ejecutada.
NORTE
1 17,53 4,25 74,50
1 1,50 4,25 6,38
1 12,46 4,25 52,96
2 1,50 4,25 12,75
1 7,30 4,10 29,93
1 12,00 3,25 39,00
SUR
1 17,53 4,25 74,50
1 1,50 4,25 6,38
1 19,95 4,25 84,79
1 2,07 3,83 7,93
1 4,80 3,64 17,47
1 0,41 3,45 1,41
1 10,47 3,25 34,03
OESTE
1 7,26 4,25 30,86
1 1,66 4,25 7,06
ESTE
1 1,78 3,25 5,79
1 5,61 3,25 18,23
1 4,95 3,25 16,09
1 0,64 3,25 2,08
P1 1 -1,80 2,10 -3,78
PE 1 -2,20 2,20 -4,84
V1 1 -3,75 0,40 -1,50
CRISTALERAS 1 1,00
Norte 1 -34,98 2,85 -99,69
1 -1,25 2,17 -2,71
Sur 1 -34,98 2,85 -99,69
1 -1,25 2,17 -2,71
1 -6,80 0,30 -2,04
Oeste 1 -7,18 2,85 -20,46
1 -1,58 2,85 -4,50
Este 1 -7,00 2,17 -15,19
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
1 7,29 3,25 23,69
NÚCLEO ASEOS
1 6,65 3,25 21,61
1 8,14 3,25 26,46
2 4,86 3,25 31,59
1 2,02 3,25 6,57
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 08 REVESTIMIENTOS
08.01 m2 ALICATADO PLAQUETA CER. VIDRIADA 15x30 cm ADHESIVO
Alicatado con plaqueta cerámica vidriada de 15x30 cm recibida con adhesivo, incluso cortes, p.p. de
piezas romas o ingletes, rejuntado y limpieza. Medida la superficie ejecutada.
ASEO H 1 12,66 2,75 34,82
P5 1 -0,83 2,03 -1,68
V1 1 -1,84 0,40 -0,74
ASEO M 1 15,17 2,75 41,72
P5 1 -0,83 2,03 -1,68
V1 1 -1,84 0,40 -0,74
V1 1 1,00
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 09 CARPINTERÍA
09.01 m2 PUERTA ENTRADA AUTOMÁTICA CON CRISTALERA
Puerta de entrada automática con cristalera, con espesor mínimo 1,2 mm con acabado en lacado,
nucleo inyectado de espuma de rígida de poliuretano de alta densidad, bulones antipalanca, cerradura
de seguridad embutida con 3 puntos de cierre, junquillos, cantoneras, mirilla, patillas de fijación, pre-
cerco de acero conformado en frio de 1,5 mm de espesor, juntas de estanqueidad de neopreno, he-
rrajes de cuelgue, cierre y seguridad y p.p. de sellado de juntas con masilla elástica; construida se-
gún CTE. Medida de fuera a fuera del cerco.
2,20 2,20
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 10 VIDRIOS
10.01 m2 ACRIST. TÉRMICO Y ACÚSTICO DOS LUNAS PULIDAS INCOLORAS 6 mm
Acristalamiento aislante térmico y acústico, formado por dos lunas pulidas incoloras de 6 mm de es-
pesor, cámara de aire deshidratado de 12 mm, perfil metálico separador, desecante y doble sellado
perimetral, colocado con perfil continuo, incluso perfil en U de neopreno, cortes y colocación de jun-
quillos; construido según CTE e instrucciones del fabricante. Medida la superficie acristalada en mul-
tiplos de 30 mm.
CRISTALERAS 1 1,00
Norte 1 34,98 2,85 99,69
1 1,25 2,17 2,71
Sur 1 34,98 2,85 99,69
1 1,25 2,17 2,71
1 6,80 0,30 2,04
Oeste 1 7,18 2,85 20,46
1 1,58 2,85 4,50
Este 1 7,00 2,17 15,19
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 11 PINTURAS
11.01 m2 PINTURA AL TEMPLE LISO S/LADRILLO, YESO O CEMENTO
Pintura al temple liso sobre paramentos verticales y horizontales de ladrillo, yeso, hormigón; Forma-
da por: lijado, plastecido, mano de fondo y manos de acabado, incluso posterior de material sobrante
Medida la superficie ejecutada.
DESCANSO - VESTIBULO 1 83,78 3,25 272,29
Vidrios 4 -1,25 2,17 -10,85
1 -1,00 2,17 -2,17
1 -2,50 2,17 -5,43
1 -3,50 2,17 -7,60
PE 1 -2,20 2,20 -4,84
P2 1 -1,74 2,34 -4,07
P3 2 -1,60 2,20 -7,04
P4 2 -0,90 2,18 -3,92
P5 1 -0,90 2,03 -1,83
REUNION 1 1 17,10 3,25 55,58
P3 1 -1,60 2,20 -3,52
REUNION 2 1 16,51 3,25 53,66
P3 1 -1,60 2,20 -3,52
VESTÍBULO ASEOS 1 8,36 3,25 27,17
P5 2 -0,83 2,03 -3,37
P6 2 -0,90 2,03 -3,65
L.TÉCNICO / ALMACÉN 1 17,54 3,25 57,01
P4 2 -0,90 2,18 -3,92
SALA COWORKING 1 86,26 4,25 366,61
1 -62,30 2,85 -177,56
1 -10,31 4,25 -43,82
P2 1 -1,74 2,34 -4,07
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CAPÍTULO 12 EQUIPAMIENTO
12.01 u PORTARROLLOS BLANCO
Portarrollos de color blanco para empotrar, recibido con mortero M5 (1:6). Medida la cantidad ejecu-
tada.
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
CÓDIGO RESUMEN UDS LONGITUD ANCHURA ALTURA PARCIALES CANTIDAD PRECIO IMPORTE
TOTAL...................................................................................................................................................................... 285.949,75
Asciende el presupuesto general a la expresada cantidad de CUATROCIENTOS ONCE MIL SETECIENTOS TREINTA Y NUEVE EUROS con CINCO
CÉNTIMOS
ÍNDICE
2. DISPOSICIONES TÉCNICAS
2.1. Materiales
2.1.1. Condiciones generales
Todos los materiales empleados deberán ser de primera calidad y no ser
procedentes de derribos, determinándose en los capítulos siguientes la
idoneidad de los mismos siendo desestimados los que el criterio de la Dirección
Técnica de la obra determine, por no reunir las condiciones que se citan.
Los productos, equipos y sistemas suministrados deberán cumplir las
condiciones que sobre ellos se especifican en los distintos documentos que
componen el Proyecto.
3. DISPOSICIONES FACULTATIVAS
Proyectista
Son obligaciones del proyectista:
Constructor
Son obligaciones del constructor:
Director de obra
Corresponde al Director de Obra en este proyecto:
Subcontratas
EI Contratista podrá subcontratar capítulos o unidades de obra a otros
contratistas e industriales, con sujeción en su caso, a lo estipulado en el Pliego
de Condiciones y sin perjuicio de sus obligaciones como Contratista general
de la obra.
4. DISPOSICIONES ECONÓMICAS
4.1. Precios
4.1.1. Principio general
Todos los que intervienen en el proceso de construcción tienen derecho a
percibir puntualmente las cantidades devengadas por su correcta actuación
con arreglo a las condiciones contractualmente establecidas. La propiedad, el
contratista y, en su caso, los técnicos pueden exigirse reciprocamente las
garantías adecuadas al cumplimiento puntual de sus obligaciones de pago.
Beneficio industrial:
EI beneficio industrial del Contratista se establece en el 6 por 100 sobre la suma
de las anteriores partidas en obras para la Administración.
Precio de Contrata:
EI Precio de Contrata es la suma de los costes directos, los Indirectos, los Gastos
Generales y el Beneficio Industrial.
EI IVA se aplica sobre esta suma (precio de contrata) pero no integra el precio.
Dentro de los diez (10) días siguientes a su recibo, el Director de Obra aceptará
o rechazará las reclamaciones del Contratista si las hubiere, dando cuenta al
mismo de su resolución, pudiendo éste, en el segundo caso, acudir ante el
propietario contra la resolución del director de obra en la forma referida en el
pliego de condiciones facultativas y legales. Tomando como base la relación
valorada indicada en el parrafo anterior, expedirá el director de obra la
certificación de las obras ejecutadas. De su importe se deducirá el tanto por
ciento que para la construcción de la fianza se haya preestablecido. EI
material acopiado a pie de obra por indicación expresa y por escrito del
propietario, podrá certificarse hasta el noventa por ciento (90 por 100) de su
importe, a los precios que figuren en los documentos del Proyecto, sin
afectarlos del tanto por ciento de contrata. Las certificaciones se remitirán al
Propietario, dentro del mes siguiente al período a que se refieren, y tendrán el
carácter de documento y entregas a buena cuenta, sujetas a las
rectificaciones y variaciones que se deriven de la liquidación final, no
4.2.6. Pagos
4.3. Garantías
4.3.1. Plazo de garantías
4.4. Fianzas
EI contratista prestará fianza con arreglo a alguno de los siguientes
procedimientos según se estipule:
4.5. Indemnizaciones
4.5.1. Indemnización por retraso del plazo de terminación de las obras
La indemnización por retraso en la terminación se establecerá en un tanto por
mil del importe total de los trabajos contratados, por cada día natural de
retraso, contados a partir del día de terminación fijado en el Calendario de
obra, salvo lo dispuesto en el pliego particular del presente proyecto. Las
sumas resultantes se descontarán y retendrán con cargo a la fianza.
5. DISPOSICIONES LEGALES
5.1. Contratas
La contratación de la obra se llevará a cabo por baja o alza media,
atendiendo a los criterios de oferta de precios, capacidad de obrar, técnica,
solvencia y no prohibición de contratar, recogidos en el proceso de licitación y
adjudicación de la obra. Se definirán en el apartado siguiente.
5.2. Responsabilidades
5.2.1. Daños materiales
a) Durante diez años, de los daños materiales causados en el edificio por vicios
o defectos que afecten a la cimentación, los soportes, las vigas, los forjados,
los muros de carga u otros elementos estructurales, y que comprometan
directamente la resistencia mecánica y la estabilidad del edificio.
b) Durante tres años, de los daños materiales causados en el edificio por vicios
o defectos de los elementos constructivos o de las instalaciones que ocasionen
el incumplimiento de los requisitos de habitabilidad del art. 3 de la L.O.E.
El constructor también responderá de los daños materiales por vicios o
defectos de ejecución que afecten a elementos de terminación o acabado
de las obras dentro del plazo de un año.
5.3. Plazos
La duración de la obra se ha calculado a través del planning de ejecución
que el Estudio de Seguridad y Salud del proyecto requiere, en base a los
rendimientos de la mano de obra y maquinaria del Banco de Precios de la
Junta de Andalucía de 2009.
Así, la duración total es seis meses, a empezar en mayo y terminar en octubre.
1. Situación ...........................................................................................................239
2. Emplazamiento........................................................................................................ 240
3. Estado actual. Distribución .................................................................................. 241
4. Estado reformado. Distribución .......................................................................... 242
5. Estado reformado. Acotado ............................................................................... 243
6. Alzados norte-sur ..................................................................................................... 244
7. Alzados este-oeste ................................................................................................. 245
8. Sección 1 - 2 ............................................................................................................. 246
9. Sección 3 - 4 ............................................................................................................. 247
10. Sección 5 ................................................................................................................... 248
11. Evacuación de aguas pluviales. Cubierta ...................................................... 249
12. Saneamiento colgado .......................................................................................... 250
13. Saneamiento enterrado ....................................................................................... 251
14. Suministro de agua ................................................................................................. 252
15. Instalación de electricidad .................................................................................. 253
16. Esquema unifilar ...................................................................................................... 254
17. Disposición de luminarias...................................................................................... 255
18. Climatización y ventilación .................................................................................. 256
19. Telecomunicaciones.............................................................................................. 257
20. Protección contra incendios ............................................................................... 258
21. Acabados ................................................................................................................. 259
22. Carpintería y cerrajería ......................................................................................... 260
Torreblanca
an de Aznalfarache
Gelves
Quintos
PLANO:
6.60
TIENDAS
50.46
87.00
PLANO:
ASEO
MUJERES
50
1.
ASEO
ASEOS MV
SALA DE DESCANSO
LOCAL
SALA COWORKING
DESPACHO
PLANO:
0.4
2
1.50
1.50
1.0
2.35 2.38 6.71
0
7.30 0.10 0.14
1.37
0.20
0.53 1.26 1.25 1.25 1.25 1.25 0.53
0.3
2.85
6
0.85
0.95
3.94
3.94
2.33
0.10
2.55
6.08
1.13 3.64
1.60
3.69
1.00
0.10
5.61
0.10
4.85
0.78
2.38 2.38 7.56
0.76
0.20 0.14
0.11
2.50
7.26
1.80
1.80
29.82
1.02
1.02
2.83
0.14
0.27
11.82
3.39
0.79
0.90
0.90
10.72
10.32
13.32
2.03
0.14 0.14
0.4
4.87 2.38 1.73 2.99
9
1.16
0.14
0.11
1.60
1.16
0.11
5.14
3.5
0
4.25
4.98
0.32
1.79
3.26
2.31
0.9
0.10
6
0.41
0.59
0.41
1.66
0.10 2.54
0.84
10.07
4.90 2.32
0.15
2.11
17.53 4.65 0.73 1.25 8.50
15.27
1.50
0.20
1.92
12.32 0.87 1.25 1.25 1.25 1.25 1.25 0.73
20.17
CUADRO DE SUPERFICIES
18
16
ZONA DE DESCANSO 95
DESPACHO 10
55
ASEO HOMBRES 8
ASEO MUJERES 11
PLANO:
ALZADO SUR
PLANO:
ALZADO ESTE
PLANO:
1' 2
PLANO:
3' 4'
PLANO:
Pte. 1.5%
Pte. 1.5%
Pte. 1%
Pte. 1%
ARQUETA DE PASO
PLANO:
BP1
P1 P2 P3
ARQUETA DE PASO
PLANO:
R2
R3
CP1
CM1
ARQUETA DE PASO
PLANO:
CONTADOR GENERAL
LLAVE DE PASO
FILTRO
GRIFO TEMPORIZADO
FLUXOR
LAVAMANOS
Acometida
PLANO:
C2 AA1
C9
A9 A6 A6 A8 A8
A9
C9
A8 A8
C1 AA3
AA2
A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A6 A6
A4 A4 C7
A3
A.E.
S4
C4
A6 A6 A6
S4 S3 S3 S2 S2 S1 S1 AA6 C7
C5
A8 A8 A8
C7
A4 A4
A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A3
C5
A6 A6 C9
C7
C1 C4
S4 A4 A4 S6
S4 S3 S3 S2 S2 S1 S1 A3
A7
A8 A8 A8
C2 C5 A7
C8 C8
A.E.
AA5
A9
A4 A4 A3
C5 S5
A3 A3 C4 A3 A3
A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 C4 A8
A.E.
A3 A3 A3
A.E.
A.E.
A3 A3
A8 A8 A8
A8
A9
C1 A3 A3 A3
C.G.M.P.
A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A.E.
AA4 C9 C9
C.P.M.
A9 A9 A9 A9 A9 A9
A5 A5 A3
C4
C6
A.E.
C3 C3 C6
A9 A9 A9 A9
A9
Acometida
CIRCUITOS
LEYENDA DE ELECTRICIDAD
CIRCUITO POTENCIA (W) CIRCUITO POTENCIA (W)
A2 SALA COWORKING DECORATIVA 312 C2 SALA COWORKING 3.450 PUNTO DE LUZ EN SUELO
I.DIF.II
25A - 30 mA
I. MAG. II
230v - 10A
I. MAG. II
230v - 10A
LEYENDA DE ELECTRICIDAD
PROMOTOR:
INTERRUPTOR DIFERENCIAL
I. MAG. II
230v - 10A
Avda. Camino de los Descubrimientos
TOMA DE TIERRA
I. MAG. II
Isla de la Cartuja. SEVILLA.
I. MAG. II
230v - 10A
I.DIF.II
25A - 30 mA
1:100
ESCALA:
I. MAG. II
230v - 10A
PLANO:
I. MAG. II
16
230v - 10A
FUERZA - TOMAS DE CORRIENTE AUXILIARES
I. MAG. II
230v - 16A
C1 - TC SALA COWORKING P = 3.450 W
I.DIF.II
25A - 30 mA
I. MAG. II
230v - 16A
C2 - TC SALA COWORKING P = 3.450 W
I. MAG. II
230v - 16A
I. MAG. II
230v - 16A
I.DIF.II
25A - 30 mA
I. MAG. II
230v - 16A
C5 - TC SALAS DE REUNIONES P = 3.450 W
I. MAG. II
C.M.P 230v - 16A
125A I.G.A. C6 - TC DESPACHO P = 3.450 W
125A
I. MAG. II
230v - 16A
C7 - TC ASEOS P = 3.450 W
I.DIF.II
25A - 30 mA
I. MAG. II
230v - 16A
TOMA A TIERRA I. MAG. II
230v - 16A
C9 - TC SALA DE DESCANSO P = 3.450 W
FUERZA - TOMAS DE CORRIENTE DE EMERGENCIA
I. MAG. II
230v - 16A
S1 - TC PUESTOS TRABAJO 1-2 P = 3.200 W
I.DIF.II
25A - 30 mA
I. MAG. II
230v - 16A
S2 - TC PUESTOS TRABAJO 3-4 P = 3.200 W
I. MAG. II
230v - 16A
S3 - TC PUESTOS TRABAJO 5-6 P = 3.200 W
ACOMETIDA
I. MAG. II
230v - 16A
S4 - TC PUESTOS TRABAJO 7-8 P = 3.200 W
I.DIF.II
25A - 30 mA
I. MAG. II
230v - 16A
S5 - TC MOSTRADOR P = 800 W
Y MEDIDA. (C.G.P.M.)
I. MAG. II
230v - 16A
S6 - TC RACK P = 30 W
I. MAG. II
230v - 16A
I.DIF.II
25A - 300 mA
I. MAG. II
230v - 16A
AA2 - UNIDAD INTERIOR 1 P = 1.650 W
I. MAG. II
230v - 16A
AA3 - UNIDAD INTERIOR 2 P = 261 W
I. MAG. II
230v - 16A
AA4 - CASETTE 1 P = 840 W
I.DIF.II
25A - 300 mA
I. MAG. II
230v - 16A
AA5 - CASETTE 2 P = 2.260 W
I. MAG. II
230v - 16A
AA5 - CASETTE 3 P = 2.260 W
MODELO UNIDADES POTENCIA (W)
PLANO:
25x15
REJILLA DE RETORNO
RXYQ10T RXYQ8T
Carga refrigerante adicional: 2.5 kg + 12.55 m (3/8") x 0.059 = 3.24 kg Carga refrigerante adicional: 2.1 kg + 11.53 m (3/8") x 0.059 = 2.78 kg
Cubierta Cubierta
UNIDAD EXTERIOR
FXMQ250MA FXSQ140P
PLANO:
Reg.de
Registro
de enlace
red
S5
Acometida
LEYENDA DE TELECOMUNICACIONES
Router WiFi
Armario RACK
PLANO:
OE OE
OE OE
OE
50
1.
9 OE
OE
47
OE OE 1
EES 23
11 39
102
OE
2 EES
LUMINARIA DE EMERGENCIA
OE
XX
PLANO:
T1 T1
D3 D3
S3 S3
T1 P3
D1
S2 P5 P5
T1
T1 D2
D2 S3
P6 S3 P6
T3
D2
S2
T2 P4 P4
D1
S1 T1 T1 T1
D1 D2 D2
S2 S2 S2
P3
P1 T3
D2
P2 S2
PE
P7
TECHOS
T1: Falso techo continuo "Placo" con lana mineral (5 cm) y doble
T1
T3: Acabado en bruto.
P2: Puerta de paso 2H. SUELOS
P3: Puerta de madera - aluminio 2H. S1 D1
P4: Puerta de madera - aluminio 1H.
S3
S1
P6: Puerta corredera 1H. 150 cm.
V1: Ventana corredera 4H. D2: Placa de yeso laminado + pintura interior marfil Perfect
Destello.
PLANO:
2.20
2.34
2.10
2.18
1.60
1.80
1.74 0.90
Tipo Abatible ciega Tipo Abatible con cristal Tipo Abatible ciega Tipo Abatible ciega
Dimensiones 1.80 x 2.10 m Dimensiones 1.74 x 2.34 m Dimensiones 1.60 x 2.20 m Dimensiones 0.90 x 2.18 m
Grosor 4 cm Grosor 3.5 cm Grosor 3.5 cm Grosor 3.5 cm
Marco Acero galvanizado Marco Aluminio Marco MDF Marco MDF
Hoja Acero galvanizado Hoja Vidrio Hoja MDF Hoja MDF
Acabado Lacado blanco Acabado Transparente Acabado Lacado blanco Acabado Lacado blanco
Herrajes Acero Herrajes Aluminio Herrajes Acero inoxidable Herrajes Acero inoxidable
Exterior - Sala coworking
0.40
2.03
3.75
2.03
2.84
0.83 0.90
0.91
Tipo Abatible ciega Tipo Corredera ciega Tipo Abatible de cristal Tipo Corredera de cristal
Dimensiones 0.83 x 2.03 m Dimensiones 0.90 x 2.03 m Dimensiones 0.91 x 2.84 m Dimensiones 3.75 x 0.40 m
Grosor 3.5 cm Grosor 3.5 cm Grosor 1 cm Grosor 2 cm
Marco MDF Marco MDF Marco Acero galvanizado Marco Acero galvanizado
Hoja MDF Hoja MDF Hoja Vidrio Hoja Vidrio
Acabado Lacado blanco Acabado Lacado blanco Acabado Acabado
Herrajes Acero inoxidable Herrajes Inoxidable Herrajes Acero inoxidable Herrajes Acero galvanizado
Aseos H - M Aseos H - M
PE
1 UNIDAD
Hoja Vidrio
Acabado Transparente
Herrajes Acero galvanizado PLANO:
MEMORIA DESCRIPTIVA
PLANOS
Topografía
Terreno sensiblemente horizontal.
Accesos
Acceso peatonal y rodado a través de avda. Camino de los
Descubrimientos y calle Tomás Alba Edison. En los planos se indica la
separación de accesos entre personas y maquinaria.
Entorno
La zona en la que se van a realizar los trabajos consta de tránsito de
peatones tanto como de vehículos por las dos calles nombradas.
Instalaciones existentes
Estructura Albañilería
Electricidad
Tratamiento de protección a Saneamiento
la estructura Fontanería
Climatización y ventilación
Cubierta plana Instalaciones
Cimentación:
Estructura:
Albañilería:
Cubierta plana:
B) Cimentación:
C) Estructura:
D) Cubierta:
RIESGOS GENERALES
MEDIOS AUXILIARES
FACTOR TÉCNICO:
FACTOR HUMANO:
FACTOR ORGANIZATIVO:
FACTOR AMBIENTAL:
Se suspenderán en caso de lluvia si sobre los elementos de las instalaciones
eléctricas no reúnen las condiciones suficientes de aislamientos.
- No procede
1.ÍNDOLE LEGAL
SEÑALIZACIONES:
- R.D. 485/97, de 14 de abril. Disposiciones mínimas en materia de señalización
de seguridad y salud en el trabajo.
EQUIPOS DE PROTECCIÓN INDIVIDUAL:
- R.D. 1.407/1.992 modificado por R.D. 159/1.995, sobre condiciones para la
comercialización y libre circulación intracomunitaria de los equipos de
protección individual-EPI.
- R.D. 773/1.997 de 30 de mayo, sobre disposiciones mínimas de seguridad y
salud relativas a la utilización por trabajadores de equipos de protección
individual.
EQUIPOS DE TRABAJO:
- R.D. 1215/1.997. Disposiciones mínimas de seguridad y salud para la utilización
por los trabajadores de los equipos de trabajo.
SEGURIDAD EN MÁQUINAS:
PROTECCIÓN ACÚSTICA:
- R.D. 1.316/1.989, del Mº de Relaciones con las Cortes y de la Secretaría del
Gobierno. 27/10/1.989. Protección de los trabajadores frente a los riesgos
derivados de la exposición al ruido durante el trabajo.
- R.D. 245/1.989, del Mº de Industria y Energía. 27/02/1.989. Determinación de la
potencia acústica admisible de determinado material y maquinaria de obra.
- Orden del Mº de Industria y Energía. 17/11/1.989. Modificación del R.D.
245/1.989, 27/02/1.989.
- Orden del Mº de Industria, Comercio y Turismo. 18/07/1.991. Modificación del
Anexo I del Real Decreto 245/1.989, 27/02/1.989.
- R.D. 71/1.992, del Mº de Industria, 31/01/1.992. Se amplía el ámbito de
aplicación del Real Decreto 245/1.989, 27/02/1.989, y se establecen nuevas
especificaciones técnicas de determinados materiales y maquinaria de obra.
- Orden del Mº de Industria y Energía. 29/03/1.996. Modificación del Anexo I del
Real Decreto 245/1.989.
2. DE CARÁCTER GENERAL
2.1. Medidas generales de organización
Se establecen las obligaciones específicas para la obra proyectada
relativas a contratista, subcontratista y trabajadores autónomos: Según el R.D.
1627/97, artículo 11, son obligaciones del contratista y subcontratista:
- Aplicar los principios de la acción preventiva que se recogen en el
artículo 15 de 31/1995 de la Ley de Prevención de Riesgos Laborales, en
particular al desarrollar las tareas o actividades indicadas en el artículo 10 del
presente Real Decreto.
- Cumplir y hacer cumplir a su personal lo establecido en el plan de
seguridad y salud al que se refiere el artículo 7.
- Cumplir la normativa en materia de prevención de riesgos laborales,
teniendo en cuenta, en su caso, las obligaciones sobre coordinación de
actividades empresariales previstas en el artículo 24 de la Ley de Prevención
SALIDA
Vestuarios
20,50 m
Acopio de material
y residuos
Comedor
15,00 m
Acopio de material
y herramientas
Aseos
15,00 m
Acceso
maquinaria
Cuadro provisional
Prohibido el paso a
toda persona ajena de obra
a la obra
Leyenda
Advertencia obras
PLANO: