Sie sind auf Seite 1von 18

ADGR_001_GRNDCLEARFOUND

BGC Interior Liningboard

BGC Duragrid™

Timber Frame

Vapour Permeable Sarking

Timber Durabatten

uPVC Cavity Closer

50mm

Damp Course
150mm min ground
clearance

Concrete Slab

Ground

Profile Duragrid™ Date Jan 2013


Detail Ground Clearance and Foundation Scale 1:2
Detail No. ADGR_001
ADGR_002_OFFSTUD

Vapour Permeable Sarking

Durabatten Timber

Timber Frame
800mm MAX CTRS

Profile Duragrid™ Date Jan 2013


Detail Off Stud Scale 1:20
Detail No. ADGR_002
ADGR_003_ONSTUD

Vapour Permeable Sarking

Durabatten Timber

Timber Frame

Profile Duragrid™ Date Jan 2013


Detail On Stud Scale 1:20
Detail No. ADGR_003
ADGR_004_BATTJOIN

Durabatten Timber

Vapour Permeable Sarking

50mm

45° Weather cut sloping down &


away from Vapour Permiable
Sarking.
Sealant
50mm

Profile Duragrid™ Date Jan 2013


Detail Batten Joining Scale 1:2
Detail No. ADGR_004
ADGR_005_PANPOSFRONTVW

10mm

Durabatten Timber

Sikaflex IIFC or similar

Polyurethane film 0.8mm - 1.00mm


thickness over exposed batten face.

10mm Expressed Join

Horizontal Backing Strip reversed & used as a spacer.

Profile Date Nov 2014


Detail Panel Position-Front View Scale 1:2
Detail No. ADGR_005
ADGR_007_FASTSPAC

Vapour Permeable Sarking


Horizontal express joint with
Durabatten Timber backing strip behind

Timber Frame Duragrid™ Panels

50mm
15mm

75mm
75mm
200 mm CTRS

50mm

Fastener spacing
200mm centres

Profile Duragrid™ Date Jan 2013


Detail Fastener Spacing Scale 1:20
Detail No. ADGR_007
ADGR_008_TYPSEALAPP

Timber Frame

BGC Duragrid™

75mm
SIKA IIFC or similar

Backing Strip

SIKA IIFC or similar


75mm

Timber Durabatten

Vapour Permeable Sarking

Profile Duragrid™ Date Jan 2013


Detail Typical Sealant Application Scale 1:2
Detail No. ADGR_008
ADGR_009_SOFFDETAIL

BGC Durasheet

Timber Frame

BGC Duragrid™

Timber Durabatten

Vapour Permeable Sarking

BGC Interior Liningboard

Profile Duragrid™ Date Jan 2013


Detail Soffit Detail Scale 1:2
Detail No. ADGR_009
ADGR_010_FOUNDDETAIL

BGC Interior Liningboard

Timber Durabatten

BGC Duragrid™

Ensure Durabatten does not sit


inside the cavity closer

uPVC Cavity Closer

Damp Course

Profile Duragrid™ Date Jan 2013


Detail Foundation Detail Scale 1:2
Detail No. ADGR_010
ADGR_011_INTCNRDETAIL

10mm

Durabatten Timber

Flashing

Polyurethane film 0.8mm - 1.00mm


thickness over exposed batten face

Sealant

Vapour Permeable Sarking

Profile Date Nov 2014


Detail Internal Corner Detail Scale 1:2
Detail No. ADGR_011
ADGR_012_EXCNRDETAIL

Vapour Permeable Sarking

Durabatten Timber

Sealant

Flashing

Polyurethane film 0.8mm


- 1.00mm thickness over
exposed batten face
10mm

Profile Date Nov 2014


Detail External Corner Detail Scale 1:2
Detail No. ADGR_012
ADGR_013_FASTPOS

Timber Stud

Nail Fastener

10mm
Expressed Joint

Durabatten Timber

Nail/Screw Fastener

Sealant

Polyurethane film 0.8mm - 1.00mm thickness


over exposed batten face

Profile Date Nov 2014


Detail Fastener Position Scale 1:2
Detail No. ADGR_013
ADGR_014_ENCLBALLPARWALL

Metal Flashing with 5° slope

70mm cover
70mm cover

Durabatten Timber

Vapour Permeable Sarking

Timber Framing

BGC Duragrid™

Profile Duragrid™ Date Jan 2013


Detail Enclosed Ballustrade/Parapet Wall Scale 1:2
Detail No. ADGR_014
ADGR_015_WINJAM

Aluminium Window Profile

Sealant

Vapour Permeable Sarking

Durabatten Timber

Duragrid™ Panels

Profile Duragrid™ Date Jan 2013


Detail Window Jamb Scale 1:2
Detail No. ADGR_015
ADGR_016_EXPJOINT

Duragrid™ Panels

Durabatten Timber

Continuous 6mm bead of SIKA IIFC or similar

Polyurethane film 0.8mm - 1.00mm


thickness over exposed batten face.

Fastener

Profile Duragrid™ Date Jan 2013


Detail Express Joint Scale 1:2
Detail No. ADGR_016
ADGR_017_WINHEAD

Durabatten Timber

Vapour Permeable Sarking

Timber Framing

BGC Duragrid™

Flashing

Packer (as required)

Aluminium window joinery

Profile Duragrid™ Date Jan 2013


Detail Window Head Scale 1:2
Detail No. ADGR_017
ADGR_018_WINSILL

Aluminium window joinery

Packer (as required)

Sill tray 5° min slope

BGC Duragrid™

Timber Framing

Vapour Permeable Sarking

Durabatten Timber

BGC Interior Liningboard

Profile Duragrid™ Date Jan 2013


Detail Window Sill Scale 1:2
Detail No. ADGR_018
ADGR_019_BNDRYWALLSYS

10mm BGC Plasterboard

Timber Frame

Vapour Permeable Sarking

16mm BGC Wet Area Fireboard


(1 or 2 layers)

Durabatten Timber

BGC Duragrid™

Profile Duragrid™ Date Jan 2013


Detail Boundary Wall System Scale 1:2
Detail No. ADGR_019