Sie sind auf Seite 1von 72

SALES CONDITIONS AND WARRANTY

Pag. 2

HUMIDITY AND TEMPERATURE TRANSMITTERS


Pag. 5

BAROMETRIC TRANSMITTERS
Pag. 9

PRICE LIST ANEMOMETERS (three-axis, two-axis, cup)


Pag. 10

ENVIRONMENTAL HD32MT.1 PROGRAMMABLE DATA LOGGER


Pag. 15
ANALYSIS HD32MT.3 DATA LOGGER
Pag. 18
01 / 2019 HD35… AND HD33… WIRELESS DATA LOGGERS
Pag. 20

RAIN GAUGES AND RAIN DETECTORS


Pag. 43

LEAF WETNESS AND SOIL VWC SENSORS


Pag. 47

TEMPERATURE PROBES
Pag. 48

PHONE: PHOTOMETERS
+39 049 89 77 150 Pag. 50

RADIOMETERS (UVA, UVB, UV index, PAR)


Pag. 50

PYRANOMETERS (secondary standard, 1st and 2nd class, silicon)


e-mail: Pag. 53
info@deltaohm.com
PYRGEOMETER
Pag. 56

PYRHELIOMETERS
FAX: Pag. 56
+39 049 635 596
ALBEDOMETERS
Pag. 57

NET IRRADIANCE METERS


Web: Pag. 57
www.deltaohm.com SUNSHINE DURATION SENSORS
Pag. 58

SIGNAL CONVERTERS / AMPLIFIERS


GHM GROUP – Delta OHM Pag. 61
Delta OHM S.r.l. a socio unico
Via Marconi 5 ACCESSORIES FOR INSTALLING THE SENSORS
35030 Caselle di Selvazzano (PD) Pag. 62
ITALY
Sales conditions
INTRODUCTION Any commercial/business relation between Delta OHM S.r.l. and the customer is exclusively governed by
the following conditions of sale which replace and supersede any other agreement.
LIABILITY Delta OHM S.r.l. shall not be liable for any direct or indirect damages arising from late or non delivery of the
product, nor for the non-correspondence of the goods to the specifications published in the catalogue or for any other event.
TECHNICAL INFORMATION We reserve the right to change without notice the technical specifications and dimensions to fit
the product's requirement.
MINIMUM AMOUNT The minimum amount per invoice, less the discount, is EUR 260. For orders of lower amounts, EUR
40 NET will be charged as costs of invoicing management (not applicable for the Calibration services).
ORDERS Only written orders received by e-mail or fax are accepted. Orders will be processed according to the customer’s
requirements, production plan permitting.
PRICES The prices here reported are meant “NET”, VAT excluded, where expected, EX-WORKS, Incoterms 2010. Delta OHM
S.r.l. reserves the right to make any change without prior notice.
SHIPMENT AND DELIVERY Our Prices DO NOT include shipping charges, which are borne by the customer. Upon specific
requests, shipping charges can be quoted and reported in the invoice, if agreed and accepted in writing. The late delivery of
our products does not create any right or remedies to the customer.
CERTIFICATES ISO9001 Calibration Reports and ACCREDIA Certificates are upon payment and are not included in the price
of the instrument. They are issued only on request and only for the instruments, not for the sensors. They have to be
requested when ordering the instrument, otherwise the instrument must be returned to our factory to be calibrated or
certified. Once Certificates or Reports are issued, it is not allowed to change the name of the addressee unless a new
certification is performed upon payment. If not required, the calibration points are at the discretion of the laboratory.
Original certificates are included in the parcel with the instrument and in no case it will be possible to send them by e-mail or
fax.
PAYMENTS In case of delayed payment, Delta OHM Srl reserves the right to charge default interests of 5% above the "Prime
Rate", in force at the date of billing.
RISK AND PROPERTY For goods shipped, the risk passes to the customer upon delivery to the carrier. The customer is
responsible for procuring insurance. It is advisable to check the integrity of the parcel at receipt of the goods.
RIGHT OF WITHDRAWAL As required by the Legislative Decree 15 January 1992, n.50, the customer has the right to
terminate the contract. The Customer wishing to exercise the "right of withdrawal" must send a written notice within 7 days
from receipt of the goods by registered mail with return receipt to: Delta OHM Srl, Via Marconi No. 5, 35030 Caselle di
Selvazzano (PD), Italy. For the application of the right to withdraw, the integrity of products and packaging is essential. The
cost of return shipment shall be borne by the customer. Delta OHM S.r.l. returns the sum, except for any costs which are
charged to the customer. Goods shipped by unauthorized carriage forward will be rejected.
REQUEST TO RETURN OF GOODS The request for return of goods must be sent to Delta OHM Srl within 7 days from
receipt of the goods by specifying the reason and quoting the Commercial Invoice. Delta OHM Srl reserves the right to charge
EUR 40.00 (EUR 60.00 for sound level meters, vibration meters, instruments for the environmental analysis) for
inspection and re-packaging In any case, it is necessary to wait for the Return Merchandise Authorization (RMA) number from
Delta OHM, which must also appear on the shipping documents. The goods must be shipped prepaid within one week of
notification of the RMA number and must be intact, in its original packaging and complete with accessories. Goods without
any of the above requirements will be rejected.
CHANGES AND CANCELLATIONS We will accept changes or cancellations of orders in progress after the written request
he customer and written confirmation from Delta OHM Srl, which reserves the right to charge the Customer the costs incurred in
eparation of the instruments, normally equal to the 20% of the amount reported on the order or the invoice.
COMPLAINTS Any shipping errors or omissions of material should be reported promptly to Delta OHM S.r.l., quoting the
invoice number, within 7 days from receipt.
WARRANTY Delta OHM Srl is required to respond to the "factory warranty" only in cases provided by Presidential Decree May
24, 1988 224. Each instrument is sold after rigorous inspections, if any manufacturing defect is found, it is necessary to contact
the distributor where the instrument was purchased. During the warranty period (24 months from date of invoice), all
manufacturing defects found will be repaired free of charge. Misuse, wear, neglect, theft and damage during transport
are excluded. Solutions, probes, electrodes and microphones are not guaranteed as the improper use, even for a
few minutes, may cause irreparable damages. Delta OHM Srl will repair those products that show technical defects of
construction according to the terms and conditions of the warranty card included in the manual of the product. Warranty is not
applied if changes, tampering or unauthorized repairs are found on the product, or for a use different from the one described
in the technical documentation, or for lack or inefficient maintenance.
OUT OF WARRANTY REPAIRS EUR 40.00 (EUR 60.00 for sound level meters, vibration meters, instruments for
environmental analysis) is charged for technical inspection of instruments sent for repair and not covered by warranty
and for request for quote or repair on instruments that do not show any anomaly.
ORIGIN CERTIFICATE, consular visa, are not included, will be charged at cost
COMPETENCE For any dispute, refer to Padua jurisdiction. The Italian law is applied, according to the Vienna Convention
(1980).
DATA TREATMENT INFORMATION The processing of your data is carried out within the database of our company and in
accordance with the provisions of GDPR 2016/679 Articles. 13 and 14 on the protection of personal data. The data, which we
guarantee is treated with the utmost confidentiality, is processed exclusively in order to comply with the rules of the
commercial contract (orders, documents of transport, invoices, processing data on behalf of third parties), for which no
expression of consent is required. Your data may only be disclosed to third parties for mandatory legislative purposes to public
and private bodies and consultants outside our company. They will not be disclosed to third parties and for them you can
request, at any time, the modification or cancellation, exercising the right. 15, 16, 17, 18, 19, 20, 21, 22 - Rights of the
interested party. This modification or cancellation can be performed by sending an email to the Owner and/or the Security
Officer of the data processing at info@deltaohm.com.
ORDERING CODES INDEX
CODE PAGE CODE PAGE

9CPRS232................................................................................ 15 HD2013-DB............................................................................. 43
BAT12V-3.4A .......................................................................... 42 HD2013R................................................................................. 43
BAT-2013DB ..................................................................... 38; 43 HD2013UA.............................................................................. 43
C.205 ....................................................................................... 15 HD2013UD.............................................................................. 43
C.205M .................................................................................... 15 HD2015 ................................................................................... 43
CON8....................................................................................... 46 HD2015.5K.............................................................................. 43
CONM12….............................................................................. 60 HD2015.5K.1 ........................................................................... 43
CP18… ...........................................................................9; 45; 58 HD2015.64K............................................................................ 43
CP2003/… ............................................................................... 10 HD2015R................................................................................. 43
CP2013.2.10............................................................................. 46 HD2016 ................................................................................... 45
CP2013.2.5............................................................................... 46 HD2016.33K............................................................................ 45
CP2013-DB .............................................................................. 43 HD2016.33K.1 ......................................................................... 45
CP23 ........................................................................................ 38 HD2016R................................................................................. 45
CP24 ......................................................................... 6; 55; 56; 60 HD2110 RS.............................................................................. 43
CP25 .................................................................................. 15; 43 HD32.35 .................................................................................. 16
CP27 .......................................................................................... 8 HD32.35FP .............................................................................. 16
CP31 ........................................................................................ 38 HD32.36 .................................................................................. 16
CP51… .................................................................................... 13 HD32.36FP .............................................................................. 17
CP52… .................................................................................... 12 HD32.D ................................................................................... 17
CP9817.3 ................................................................................... 6 HD32.D.GPS ........................................................................... 17
CPM12-8D... ...................................................................... 49; 60 HD32.VACFV ......................................................................... 17
CPM12AA…............................................................... 8; 9; 12; 60 HD32MT.1 .............................................................................. 15
FCM12.4 .................................................................................. 43 HD32MT.3K............................................................................ 18
FCM12.8 .................................................................................. 43 HD32MT.ALM ................................................................... 15; 18
GHM-CLOUD ......................................................................... 38 HD32MT.SWD ................................................................... 18; 40
HD2003 ................................................................................... 10 HD32MTLogger ................................................................. 15; 43
HD2003.1................................................................................. 10 HD32WSF.S12 ........................................................................ 40
HD2003.1R .............................................................................. 10 HD33M.GSM .......................................................................... 39
HD2003.71............................................................................... 67 HD33M4b.GSM ....................................................................... 39
HD2003.71K1 .......................................................................... 67 HD33M-MB.GSM ................................................................... 41
HD2003.74............................................................................... 67 HD33MT.3G............................................................................ 42
HD2003.75......................................................................... 43; 66 HD33MT.GSM ........................................................................ 42
HD2003.75K ............................................................................ 67 HD33MT4b.3G ........................................................................ 42
HD2003.75K1 .......................................................................... 67 HD33MT4b.GSM...................................................................... 42
HD2003.77/40 ............................................................... 43; 56; 66 HD35.24C................................................................................ 38
HD2003.77C ............................................................................ 66 HD35.24W............................................................................... 38
HD2003.78.................................................................... 43; 45; 66 HD35AP .................................................................................. 21
HD2003.78K ............................................................................ 67 HD35AP3GMT ........................................................................ 21
HD2003.78K1 .......................................................................... 67 HD35AP-CFR21 ...................................................................... 38
HD2003.79K ............................................................................ 66 HD35APD ............................................................................... 21
HD2003.83......................................................................... 58; 67 HD35APG ............................................................................... 21
HD2003.83.1 ................................................................. 56; 58; 67 HD35APGMT .......................................................................... 21
HD2003.85K ...................................................................... 56; 67 HD35APR................................................................................ 21
HD2003K................................................................................. 67 HD35APS ................................................................................ 21
HD2003K1 ............................................................................... 67 HD35AP-S ............................................................................... 38
HD2003R ................................................................................. 10 HD35APW............................................................................... 21
HD2003V................................................................................. 10 HD35-BAT2 ............................................................................ 38
HD2003VD .............................................................................. 10 HD35EDMTC.......................................................................... 33
HD2004.20.40 .......................................................................... 66 HD35EDW14b7PTC ................................................................ 28
HD2004.20.40C......................................................................... 66 HD35EDW14bNTC ................................................................. 28
HD2004.20.40K ........................................................................ 66 HD35EDW17PTC.................................................................... 27
HD2004.20.60 .......................................................................... 66 HD35EDW1N7PRTC ............................................................... 29
HD2004.22K ............................................................................ 67 HD35EDW1NLTC ................................................................... 30
HD2004.25K ............................................................................ 67 HD35EDW1NPTC ................................................................... 30
HD2004.30............................................................................... 67 HD35EDW1NRTC................................................................... 28
HD2004.30K ...................................................................... 18; 67 HD35EDW1NTC ..................................................................... 27
HD2005.20......................................................................... 18; 62 HD35EDW1NTV ..................................................................... 27
HD2013 ................................................................................... 43 HD35EDW1NTVI.................................................................... 27
HD2013.18......................................................................... 43; 45 HD35EDW7PRTC ................................................................... 29
HD2013.2................................................................................. 46 HD35EDWDPTC ..................................................................... 31
HD2013.2.14 ............................................................................ 66 HD35EDWH............................................................................ 32
HD2013.2.17 ............................................................................ 66 HD35EDWHE ......................................................................... 32
HD2013.2D .............................................................................. 46 HD35EDW-MB ....................................................................... 32
HD2013.5K .............................................................................. 43 HD35EDWNPTC ..................................................................... 30
HD2013.5K.1 ........................................................................... 43 HD35EDWPTC........................................................................ 29
3
ORDERING CODES INDEX
CODE PAGE CODE PAGE
HD35EDWPTC-ALM .............................................................. 30 KIT 16.16 ................................................................................ 56
HD35EDWRPTC ..................................................................... 29 LPG ....................................................... 50; 53; 54; 56; 57; 58; 60
HD35EDWRTC ....................................................................... 28 LPNET07................................................................................. 57
HD35EDWS/2TC ..................................................................... 31 LPNET14................................................................................. 57
HD35EDWS/3TC ..................................................................... 31 LPPAR03................................................................................. 52
HD35EDWSTC ........................................................................ 31 LPPAR04BL ............................................................................ 50
HD35REW ............................................................................... 35 LPPHOT02 .............................................................................. 50
HD3901…................................................................................ 47 LPPHOT03 .............................................................................. 52
HD3910.................................................................................... 47 LPPHOTS ................................................................................ 51
HD48…07TFP… ....................................................................... 8 LPPIRG01 ............................................................................... 56
HD4817CAL .............................................................................. 8 LPPYRA02 .............................................................................. 54
HD4907TFP… ........................................................................... 8 LPPYRA03 .............................................................................. 55
HD4V8TBARO .......................................................................... 9 LPPYRA05 .............................................................................. 57
HD51.3D… .............................................................................. 13 LPPYRA06 .............................................................................. 57
HD5110 ............................................................................. 15; 18 LPPYRA08 .............................................................................. 55
HD5150 ................................................................................... 15 LPPYRA10 .............................................................................. 53
HD52.30K.......................................................................... 12; 13 LPPYRA11 .............................................................................. 57
HD52.3D.................................................................................. 11 LPPYRA12 .............................................................................. 54
HD52.3D-S ........................................................................ 12; 13 LPPYRA13 .............................................................................. 53
HD52.3DV ............................................................................... 12 LPPYRHE16............................................................................ 56
HD5320.............................................................................. 15; 18 LPRAD03 ................................................................................ 52
HD53GSM ............................................................................... 15 LPRING02 .............................................................. 50; 53; 54; 56
HD53LS ................................................................................... 11 LPRING04 .......................................................................... 54; 55
HD54.1K.................................................................................. 65 LPRING12 .......................................................................... 53; 54
HD54.3 .................................................................................... 14 LPRING13 ............................................................................... 55
HD54.9K............................................................................ 14; 67 LPS1 ....................................................................... 50; 53; 54; 56
HD54.9K1................................................................................ 67 LPS2 ........................................................................................ 55
HD54.D.................................................................................... 14 LPS3 ........................................................................................ 55
HD7520R ................................................................................. 15 LPS6 ....................................................................... 50; 55; 56; 70
HD778 TCAL........................................................................... 61 LPSD18… ............................................................................... 58
HD9006 ..................................................................................... 8 LPSG ..................................................... 50; 53; 54; 56; 57; 58; 60
HD9006.14................................................................................. 8 LPSILICON-PYRA 04 ............................................................. 56
HD9007.T29.1.......................................................................... 49 LPSP1.......................................................... 50; 53; 54; 56; 57; 60
HD9007.T29K.......................................................................... 49 LPSP2........................................................................... 55; 57; 60
HD9007A-1.......................................................................... 7; 36 LPSP3................................................................................. 57; 60
HD9007A-2.......................................................................... 7; 36 LPSP4...................................................................................... 60
HD9007T26.2....................................................................... 7; 36 LPUVA02 ................................................................................ 50
HD9008.03................................................................................. 5 LPUVA03 ................................................................................ 52
HD9008.1................................................................................... 5 LPUVB02 ................................................................................ 50
HD9008.21.1 .............................................................................. 7 LPUVB03 ................................................................................ 52
HD9008.21.2 .............................................................................. 7 LPUVI02 ................................................................................. 50
HD9008.26/14 ............................................................................ 7 Meteo Studio............................................................................ 18
HD9008.31................................................................................. 7 P1 .............................................................................................. 5
HD9008T17S ............................................................................. 5 P2 .............................................................................................. 5
HD9008T7AC ............................................................................ 5 P3 .............................................................................................. 5
HD9008T7S ............................................................................... 5 P4 .............................................................................................. 5
HD9008TR… ............................................................................. 5 P6............................................................................................... 7
HD9009TR… ............................................................................. 5 P7............................................................................................... 7
HD9408.3B… ............................................................................ 9 P8............................................................................................... 7
HD9408….................................................................................. 9 PFV.30W ............................................................................ 18; 67
HD978TR3............................................................................... 61 RS2003 .................................................................................... 10
HD978TR4............................................................................... 61 RS48................................................................................. 8; 9; 58
HD978TR5............................................................................... 61 RS51K ..................................................................................... 13
HD978TR6............................................................................... 61 RS52.....................................................................................9; 12
HD9817T… ............................................................................... 6 SWD06 .................................................................................... 38
HD9906.51............................................................................... 54 TP32MT…............................................................................... 48
HD9908TBARO ......................................................................... 9 TP32MTT.03 ........................................................................... 49
HDF2414 ................................................................................. 15 TP32MTT.03.1......................................................................... 49
HDMB3180.............................................................................. 15 TP32MTT.03.A… .................................................................... 48
HDRMO169............................................................................. 15 TP32MTT.03.B… .................................................................... 48
HDTCF-142-M......................................................................... 15 TP32MTT.03.C… .................................................................... 48
HP3501… ................................................................................ 37 TP350N…................................................................................ 36
HP3510… ................................................................................ 37 TP35878ISS… ......................................................................... 37
HP3517… ................................................................................ 36 TP878.1SS.O ........................................................................... 49
HP712 ...................................................................................... 37
4
ENVIRONMENTAL ANALYSIS
ELEMENTS FOR WEATHER STATIONS

MODEL HUMIDITY AND TEMPERATURE TRANSMITTERS EURO

HD9008.03 Direct Pt100 1/3 DIN temperature sensor for measuring the air temperature. Measuring range -40…+80 °C. 3 or 4 wires 95
connection. Probe ∅ 26 mm, L = 185 mm.
HD9008.1 Meteorological relative humidity transmitter. Relative humidity measuring range: 0...100 % R.H., 4mA corresponds to 176
0% R.H., 20mA corresponds to 100%R.H. Probe ∅ 26 mm, L = 185 mm. Power supply 10...30Vdc.
HD9008T7AC Meteorological temperature transmitter. It measures the temperature with Pt100 1/3 DIN sensor. Measuring range 154
-40 °C...+80 °C. 4…20 mA output signal, 4 mA correspond to -40 °C, 20 mA correspond to +80 °C. Power supply
10...30 Vdc. Probe ∅ 26 mm, L = 185 mm.
HD9008T7S Meteorological temperature transmitter. It measures the temperature with Pt100 1/3 DIN sensor. Measuring range 162
-40 °C…+80 °C. Power supply 5…30 Vdc, RS485 MODBUS-RTU output signal. Probe ∅ 26 mm, L= 185 mm.
HD9008T17S Meteorological temperature and relative humidity transmitter. It measures the temperature with Pt100 1/3 DIN sensor. 286
Temperature measuring range -40 °C…+80 °C. Relative humidity measuring range 0…100%R.H. Power supply
5…30 Vdc, RS485 MODBUS-RTU output signal. Probe ∅ 26 mm, L= 185 mm.
HD9008TRR Configurable dual meteorological temperature and relative humidity transmitter. Measuring range: temperature 260
-40°C...+80°C, relative humidity 0...100% R.H., 4mA correspond to –40°C and 0% R.H., 20mA correspond to +80°C
and 100%R.H. Probe ∅ 26 mm, L = 185 mm. Power supply 10...30Vdc.
HD9008TR.2 Meteorological temperature and relative humidity transmitter. It measures the temperature with 4-wire Pt100 sensor. 250
Measuring range: relative humidity 0…100%R.H., 4mA correspond to 0%R.H., 20mA correspond to 100%R.H. Power
supply 10…30Vdc. Probe ∅ 26 mm L= 185 mm.
HD9009TRR Configurable dual meteorological temperature and relative humidity transmitter. Measuring range: temperature 260
-40°C...+80°C, relative humidity 0...100% R.H., 0Vdc correspond to -40°C and 0% R.H., 1Vdc correspond to +80°C and
100%R.H. Probe ∅ 26 mm, L = 185 mm. Power supply 5...35Vdc, 2mA.
HD9009TR.1 Meteorological temperature and relative humidity transmitter. It measures the temperature with 2-wire Pt100 sensor. 250
Measuring range: relative humidity 0…100%R.H., 0Vdc correspond to 0%R.H., 1Vdc correspond to 100%R.H. Power
supply 5…35Vdc, 2mA. Probe ∅ 26 mm L= 185 mm.
HD9009TR.2 Meteorological temperature and relative humidity transmitter. It measures the temperature with 4-wire Pt100 sensor. 250
Measuring range: relative humidity 0…100%R.H., 0Vdc correspond to 0%R.H., 1Vdc correspond to 100%R.H. Power
supply 5…35Vdc, 2mA. Probe ∅ 26 mm L= 185 mm.

P1 Technopolymer and 34µm stainless steel grid protection for probes ∅26 mm, thread M24x1.5. Operating temperature: -40…80 17
°C.
P2 Technopolymer and 20µm sintered PE protection for probes ∅26 mm, thread M24x1.5. Operating temperature: -40…80 °C. 20
P3 20µm sintered bronze protection for probes ∅26 mm, thread M24x1.5. Operating temperature: -40…150 °C. 25
P4 20µm sintered PE protection for probes ∅26 mm, thread M24x1.5. Operating temperature: -40…80 °C. 20

For the meteorological shield and other accessories see pag. 7

5
METEOROLOGICAL DIGITAL HUMIDITY AND TEMPERATURE
MODEL EURO
TRANSMITTERS
HD9817T1R Dual temperature and relative humidity transmitter. 1/3 DIN Pt100 temperature sensor. Measuring range for relative humidity: 239
0...100%RH, for temperature: -40...+60°C. Double output signal 0...1Vdc. Power supply 5...35Vdc. Housing made of AISI
304, dimensions ∅ 14mm, L= 145mm. Standard configuration 0...100%RH = 0...1Vdc, -40...+60°C = 0...1Vdc. 7-wire cable
with shield L = 1.5m. Supplied with HD9817TC software with basic and calibration management functions
HD9817T2R Dual temperature and relative humidity transmitter. Pt100 1/3 DIN temperature sensor. Measuring range for relative 261
humidity: 0...100%RH, for temperature: -40...+60°C. RS232C output. Non-isolated power supply: power supply comes
from RS232C PC output. Housing made of AISI 304, dimensions ∅ 14mm, L=145mm. Standard configuration
0...100%RH for relative humidity and -40...+60°C for temperature. Output cable with DB9 female connector, L=2m.
Baud rate 2400. Supplied with HD9817TC software with basic and calibration management functions
HD9817T3R Dual temperature and relative humidity transmitter. Pt100 1/3 DIN temperature sensor. Measuring range for relative 261
humidity: 0...100%RH, for temperature: -40...+60°C. USB output isolated type 1.1 – 2.0. Power supply comes from USB
PC output. Housing made of AISI 304, dimensions ∅ 14mm, L=145mm. Standard configuration 0...100%RH for relative
humidity and -40...+60°C for temperature. Output cable with USB B type connector, L = 2m. Supplied with HD9817TC
software with basic and calibration management functions

HD9817TVS Dual humidity and temperature transmitter, Pt100 sensor. 0...1 Vdc analog outputs and RS485 MODBUS-RTU output. 318
Temperature measuring range -40...+60 °C. Power supply 5...30 Vdc. AISI 304 housing. IP 65 probe protection degree.
Dimensions ∅14 x 155 mm. Output with 8-pole M12 male connector. Supplied with CP9817.3 cable, length 3 m.

CP24 PC connecting cable for the MODBUS parameters configuration of the HD9817TVS transmitter. With built-in 70
RS485/USB converter. 8-pole M12 connector on instrument side and A-type USB connector on PC side.

CP9817.3 Spare cable for HD9817TVS transmitter, with 8-pole M12 female connector on one side, open wires on the other side. 43
Length 3 m.

6
ACCESSORIES FOR TEMPERATURE AND HUMIDITY
MODEL EURO
TRANSMITTERS
HD9007A-1 12-ring meteorological shield for HD9008… and HD9009... transmitters. 131
HD9007A-2 16-ring meteorological shield for HD9008… and HD9009... transmitters, for hot climates. 140
HD9007T26.2 Fitting for Ø 14 mm transmitters for the protections from solar radiations HD9007A-1 and HD9007A-2. 18
P6 10µm sintered stainless steel protection for probes ∅14 mm, thread M12x1. Operating temperature: -40…180 °C. 30
P7 20µm PTFE protection for probes ∅14 mm, thread M12x1. Operating temperature: -40…150 °C. 30
P8 PBT and 10µm stainless steel grid protection for probes ∅14 mm, thread M12x1. Operating temperature: -40…120 °C. 23
HD9008.21.1 Flange with support, ∅ 26mm hole for vertical probes, 250mm distance from the wall (for 39
HD9008/ HD9008TRK / HD9009). An adapter from ∅ 26mm to ∅ 14mm for probes of the
series TC of temperature and relative humidity transmitters is requested.
HD9008.21.2 Flange with support, ∅ 26mm hole for vertical probes, 125mm distance from the wall (for 42
HD9008/ HD9008TRK / HD9009). An adapter from ∅ 26mm to ∅ 14mm for probes of the
series TC of temperature and relative humidity transmitters is requested.
HD9008.26/14 Adapter from ∅ 26mm to ∅ 14 for probes of the TC series for temperature and R.H. transmitters. 18

HD9008.31 Wall flange with ∅ 14 cable outlet to fix all combined °C and R.H. probes of the TO and TC 45
series.

7
ACTIVE AND PASSIVE TEMPERATURE TRANSMITTERS
MODEL
FOR SOLAR PANELS
Active (HD48…) or passive (HD49…) temperature transmitters. HD48… is available with
active 4÷20 mA or 0÷10 V analog output, or with RS485 MODBUS-RTU output only.
HD49… is available with passive 4÷20 mA analog output. Supplied with contact
temperature probe for solar panels with 5, 10 or 30 m cable, thin film 1/3 DIN Pt100
sensor. Probe temperature range: -40…+85 °C. Also available with LCD display (option L).
Electronics working temperature: -20…+60 °C. Power supply: 18 ÷ 40 Vdc or 24 Vac for
HD48… models, 12 ÷ 40 Vdc for HD49… models. On request, HD48… is available with
power supply 90 ÷ 240 Vac only in housing 80 x 120 mm, height 56 mm, without display.
VERSIONS OPTION
FP.5 FP.10 FP.30 L
Probe cable L=5 m Probe cable L=10 m Probe cable L=30 m LCD
OUTPUT EURO EURO EURO EURO
HD4807T… 4 ÷ 20 mA active 220 272 429 57
HD48V07T… 0 ÷ 10 V 220 272 429 57
HD48S07T… RS485 MODBUS 220 272 429 57
HD4907T… 4 ÷ 20 mA passive 220 272 429 57

HD48 07T FP. L L = with LCD display

Blank = 4…20 mA analog output Cable length


V = 0…10 Vdc analog output 5 = 5 m, 10 = 10 m, 30 = 30 m
S = RS485 MODBUS-RTU output only

HD4907TFP L L = with LCD display


Cable length
5 = 5 m, 10 = 10 m, 30 = 30 m

CP27 Serial connection cable with USB connector for PC and 3-pole connector for COM AUX port. The cable has a 70
built-in USB / RS232 converter and connects the transmitter directly to the USB port of the PC. This cable is suitable
only for the models with analog output.
RS48 Cable for RS485 connection with built-in USB / RS485 converter. The cable has USB connector for PC and 3 separate 70
wires for the instruments. This cable is suitable for the models with RS485 output only.
HD4817CAL CD-ROM with the software HD4817CAL for the configuration of the transmitters. For Windows® operating systems. 50

MODEL ASPIRATED AIR TEMPERATURE PROBE EURO

HD9006 Aspirated air temperature probe, Pt100 sensor, with protective shield against the radiations. Power supply 12 Vdc, On request
max 35 mA. 8-pole M12 connector, on request 10 m standard cable (other lengths available on request) complete with
∅ 16 mm length 580 mm rod.

HD9006.14 Flange to install the HD9006 aspirated air temperature probe to the 40 ÷ 50 mm diameter mast. On request
CPM12AA8.2 8-pole cable. Length 2m. 8-pole M12 connector on one end, open wires on the other side 39
CPM12AA8.5 8-pole cable. Length 5m. 8-pole M12 connector on one end, open wires on the other side 49
CPM12AA8.10 8-pole cable. Length 10m. 8-pole M12 connector on one end, open wires on the other side 84

8
MODEL BAROMETRIC TRANSMITTERS EURO

HD9408.3B.1 Precision barometric transmitter. Measuring range: 500…1200 hPa for the analog outputs, 1200
0…1350 hPa for the digital outputs. Accuracy: ± 0.1 hPa (500…1200 hPa) @ 23 °C. NET
Working temperature -40…+85 °C. 0…5 V or 1…5 V configurable voltage analog
output. RS232, RS422 or RS485 digital output. MODBUS-RTU and NMEA standard
protocols. Power supply 10…30 Vdc. IP 67 housing. The cable CP18.2 (L=2m) or
CP18.5 (L=5m) with free 8-pole M12 female connector must be ordered separately.
HD9408.3B.2 Precision barometric transmitter. Measuring range: 500…1200 hPa for the analog outputs, 1200
0…1350 hPa for the digital outputs. Accuracy: ± 0.1 hPa (500…1200 hPa) @ 23 °C.
NET
Working temperature -40…+85 °C. 0…20 mA or 4…20 mA configurable current analog
output. RS232, RS422 or RS485 digital output. MODBUS-RTU and NMEA standard
protocols. Power supply 10…30 Vdc. IP 67 housing. The cable CP18.2 (L=2m) or
CP18.5 (L=5m) with free 8-pole M12 female connector must be ordered separately.
HD9408.3B.3 Precision barometric transmitter. Measuring range: 0…1350 hPa. Accuracy: ± 0.1 hPa 1200
(500…1200 hPa) @ 23 °C. Working temperature -40…+85 °C. SDI-12 digital output.
NET
Power supply 10…30 Vdc. IP 67 housing. The cable CPM12AA4.2 (L=2m) or
CPM12AA4.5 (L=5m) with free 4-pole M12 female connector must be ordered
separately.
CP18.2 12-pole cable. Length 2 m. 8-pole M12 connector on one end, open wires on the other side. For HD9408.3B.1 and 48
HD9408.3B.2 transmitters.
CP18.5 12-pole cable. Length 5 m. 8-pole M12 connector on one end, open wires on the other side. For HD9408.3B.1 and 85
HD9408.3B.2 transmitters.
CPM12AA4.2 4-pole cable. Length 2m. 4-pole M12 connector on one end, open wires on the other side. For HD9408.3B.3 transmitter. 33
CPM12AA4.5 4-pole cable. Length 5m. 4-pole M12 connector on one end, open wires on the other side. For HD9408.3B.3 transmitter. 44
RS48 Cable for RS485 connection with built-in USB/RS485 converter. The cable has USB connector for PC and 3 separate 70
wires for the instruments. The cable is used to configure HD9408.3B.1 and HD9408.3B.2 transmitters before the
installation. Length 2 m.
RS52 Serial connection cable with built-in USB/RS232 converter. USB connector for the PC and screw terminals on the 70
instrument side. The cable is used to configure HD9408.3B.1 and HD9408.3B.2 transmitters before the installation.
Length 1.5 m.

HD4V8TBARO Barometric transmitter to wall mount for indoor use, with 0…1 Vdc analog output. Measuring range 204
600…1100mbar. Power supply 10…40 Vdc. Working temperature -30°C… 60°C.
Housing dimensions 58 x 64 x 35 mm.
Suitable for installation in the housings for weather stations HD32.35, HD32.35FP, HD32.36 and
HD32.36FP.

HD9408TBARO Barometric transmitter output 0…1 Vdc, measuring range 800…1100 mbar. 215
Power supply 8...35 Vdc. Working temperature -30 °C…+60 °C. On
request, output: 0…5 Vdc, 1…5 Vdc, 1…6 Vdc, 0…10 Vdc or 4…20 mA.

HD9408TRBARO Barometric transmitter output 0…1 Vdc, measuring range 800…1100 mbar. 239
Power supply 12…35 Vdc. Working temperature -40 °C…+60 °C,
integrated heater sensor. Typical consumption at 20 °C: 20 mA. On
request, output: 0…5 Vdc, 1…5 Vdc, 1…6 Vdc or 0…10 Vdc.

HD9908TBARO Digital barometric transmitter with LCD indication, 3½ digit, minimum and 273
maximum relay. Power supply 24 Vac (on request 230 Vac). Working
temperature -20 °C…+60 °C. Outputs: 0…20 mA, 4…20 mA, 0…1 Vdc,
0…5 Vdc. On request, output 0…10 Vdc.

HD9408PS50K Kit including: 154


• HD9408PS50 barometric pressure static port.
• HD9408PS56 support bracket (for the HD9408PS50 static port).
• HV55 UV and temperature resistant silicone tube, internal diameter
3 mm, external diameter 6 mm, length 400 mm.

9
MODEL 3-AXIS ULTRASONIC ANEMOMETERS EURO

HD2003 Ultrasonic static anemometer for measuring wind speed and direction, air temperature, relative humidity 2968
and barometric pressure. Wind speed and direction, U-V-W Cartesian Components of speed, sound speed,
sonic temperature. Five analog outputs in different voltage and current, different ranges. Communication
software for bi-directional links for net connection of different anemometers, interfaces available RS232
and RS485 with proprietary or MODBUS-RTU protocol. Different measuring units and average periods
are available. Ultrasonic transducers heating as optional. 12..30 Vdc power supply, 120mA consumption at
15Vdc. To be mounted on a mast diam.33mm. Connector CP2003/C included.

HD2003R Transducers heating option for HD2003 against ice or snow. 451

HD2003.1 Ultrasonic static anemometer for measuring wind speed and direction. Wind speed and direction, U-V-W 2279
Cartesian Components of speed, sound speed, sonic temperature. Five analog outputs in different voltage
and current, different ranges. Communication software for bi-directional links for net connection of
different anemometers, interfaces available RS-232 and RS-485 with proprietary or MODBUS-RTU
protocol. Different measuring units and average periods are available. Transducers heating as optional.
12..30 Vdc power supply, 120mA consumption at 15Vdc. To be mounted on a mast diam.33mm.
Connector CP2003/C included.

HD2003.1R Transducers heating option for HD2003.1 against ice or snow. 410
HD2003V White powder coating on anodized body. 136
HD2003VD Desert colour powder coating on anodized body. 136
INSTALLATION OF HD2003 AND HD2003.1 ANEMOMETERS

ACCESSORIES FOR HD2003 AND HD2003.1 ANEMOMETERS


CP2003/5 26-pole shielded cable diam. 8mm, length 5m. Complete with watertight connector at one side and open wires at the other end. 130
CP2003/10 26-pole shielded cable diam. 8mm, length 10m. Complete with watertight connector at one side and open wires at the other end. 175
CP2003/15 26-pole shielded cable diam. 8mm, length 15m. Complete with watertight connector at one side and open wires at the other end. 205
CP2003/20 26-pole shielded cable diam. 8mm, length 20m. Complete with watertight connector at one side and open wires at the other end. 255
CP2003/30 26-pole shielded cable diam. 8mm, length 30m. Complete with watertight connector at one side and open wires at the other end. 318
CP2003/C Further watertight 26-pole connector. 40
RS2003 Serial connection cable with built-in USB/RS232 converter. USB connector for the PC and watertight 26-pole connector on the 125
instrument side. Length 1.5 m.

10
MODEL 2-AXIS ULTRASONIC ANEMOMETERS
HD52.3D… 2-axes ultrasonic static anemometer for the measurement of wind speed and direction, U-V Cartesian components of wind speed, Wind Gust,
relative humidity and temperature (optional), global solar radiation (optional) and barometric pressure (optional). Equipped with compass.
RS232, RS485, RS422 and SDI-12 serial outputs, NMEA, MODBUS-RTU and SDI-12 communication protocols. Two analog outputs, one
for wind speed and one for wind direction, factory-configurable within 4÷20 mA (standard), 0÷1 V, 0÷5 V or 0÷10 V (to be specified when
ordering). Heater option available. Power supply: 10…30 Vdc (15…30 Vdc in case of 0÷10 V analog outputs). Installation on mast
∅ 40 mm external and ∅ 36 mm internal. Input with 19-pole M23 male connector and 19-pole M23 female free connector. It includes
HD52.3D-S software downloadable from Delta OHM website. On request, 5 m, 10 m, 15 m or 20 m CP52… cable with M23 connector
on one end and open wires on the other.

BASIC VERSION OPTIONS


Wind speed and Relative humidity
Barometric pressure Solar radiation Heating
direction Temperature
HD52.3D HD52.3D…4… HD52.3D…17… HD52.3D…P… HD52.3D…R
EURO EURO EURO EURO EURO
1309 + 215 + 314 + 347 + 176

R = heating option
HD 52.3D Blank = not heated

P = solar radiation option


4 = barometric pressure option
17 = relative humidity and temperature option
P4 = solar radiation and barometric pressure option
P17 = solar radiation, relative humidity and temperature option
147 = barometric pressure, relative humidity and temperature option
P147 = solar radiation, barometric pressure, relative humidity and temperature option
Blank = basic version

Analog outputs for wind speed and direction: 4…20 mA standard; on request 0…1 V, 0…5 V or 0…10 V (0…10 V option
needs 15…30 Vdc power supply). The two outputs are for wind speed and direction only.
Note: the Dew Point measurement is available with MODBUS-RTU, NMEA, SDI-12 standard protocols and with HD52-3D-S software; it
is not available in proprietary RS232 and RS485 modes.

HD52.3D HD52.3DP HD52.3DP17 HD52.3D17


HD52.3D4 HD52.3DP4 HD52.3DP147 HD52.3D147

VERSIONS WITH ANALOG OUTPUTS ONLY EURO

HD52.3DAC Version of the HD52.3D anemometer with only RS232 serial output for the configuration and two 4÷20 mA analog outputs for On
wind speed and direction. 8-pole M12 connector. Available with heating option. It includes HD52.3D-S software
request
downloadable from Delta OHM website. Supplied with: female 8-pole M12 movable connector and operating manual. On
request, 5 m, 10 m or 20 m CPM12 AA8… cable with M12 connector on one end and open wires on the other.

HD52.3DAF Version of the HD52.3D anemometer with two analog outputs: one frequency output, to simulate a cup anemometer, and On
one potentiometric output, to simulate a vane wind direction sensor. 8-pole M12 connector. Available with heating
option. Supplied with: female 8-pole M12 movable connector and operating manual. On request, 5 m, 10 m or 20 m
request
CPM12 AA8… cable with M12 connector on one end and open wires on the other.

HD53LS Version of the HD52.3D anemometer with analog output or RS485 MODBUS-RTU output (to be specified when ordering). 850
Measuring range 0…50 m/s. Operating temperature -20…+55 °C. 8-pole M12 connector. Supplied with: female 8-pole M12
movable connector. On request, 5 m, 10 m or 20 m CPM12 AA8… cable with M12 connector on one end and open wires
on the other.

11
MODEL INSTALLATION OF HD52.3D... ANEMOMETERS EURO

ACCESSORIES FOR HD52.3D... ANEMOMETERS EURO

HD52.3D-S CD-ROM with HD52.3D-S software for PC connection, instrument configuration and monitor. For Windows® operating 50
systems. The CD also includes a software for the Modbus connection to PC.
RS52 Serial connection cable with built-in USB/RS232 converter. USB connector for the PC and screw terminals on the 70
instrument side. The cable is used to configure the instrument before the installation. Length 1.5 m.
HD52.30K Birds spikes for HD52.3D…. and HD51.3D…. 125
HD52.3DV White powder coating on HD53.3D... spacing bars. 58
CP52.5 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 5 m. 125
CP52.10 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 10 m. 165
CP52.15 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 15 m. 205
CP52.20 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 20 m. 250
CP52.30 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 30 m. 330
CP52.50 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 50 m. 410
CP52.75 12-wire connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 75 m. 480
CP52.C Further 19-pole M23 movable female connector. 40
CPM12AA8.5 8-pole cable. Length 5m. 8-pole M12 connector on one end, open wires on the other side 49
CPM12AA8.10 8-pole cable. Length 10m. 8-pole M12 connector on one end, open wires on the other side 84
CPM12AA8.20 8-pole cable. Length 20m. 8-pole M12 connector on one end, open wires on the other side 156

12
HIGH PERFORMANCE
MODEL EURO
2-AXIS ULTRASONIC ANEMOMETER
HD51.3D4R 2-axis ultrasonic static anemometer. Measurement of wind speed (up to 85 m/s) and direction, U-V Cartesian components of 1690
wind speed, Wind Gust and barometric pressure. Isolated RS232, RS485, and RS422 serial outputs. NMEA, MODBUS-
RTU and ASCII proprietary communication protocols. Two analog outputs for wind speed and direction, factory-
configurable within 4÷20 mA (standard), 0…1 V, 0…5 V or 0…10 V (to be specified when ordering). Equipped with
heater. Operating temperature -40…+60 °C. Instrument power supply 12…30 Vdc. Heater power supply 24 Vdc. Housing
in ASA. Installation on mast ∅ 40 mm external and ∅ 36 mm internal. Input with 19-pole M23 male connector and 19-pole
M23 female free connector. The HD52.3D-S software, for instrument configuration and monitor, downloadable from Delta
OHM website is included. CP51… cable on request.

HIGH PERFORMANCE FOR HARSH ENVIRONMENTS


2-AXIS ULTRASONIC ANEMOMETER
HD51.3D4R-AL 2-axis ultrasonic static anemometer. Measurement of wind speed (up to 80 m/s) and direction, U-V Cartesian components of 1990
wind speed, Wind Gust and barometric pressure. Isolated RS232, RS485, and RS422 serial outputs. NMEA, MODBUS-
RTU and ASCII proprietary communication protocols. Two analog outputs for wind speed and direction, factory-
configurable within 4÷20 mA (standard), 0…1 V, 0…5 V or 0…10 V (to be specified when ordering). Equipped with an
enhanced heater for rapid defrosting. Satisfies the requirements of the MIL-STD-810G Method 509.6 standard (salt fog
anti-corrosion test). Operating temperature -40…+60 °C. Instrument power supply 12…30 Vdc. Heater power supply 24
Vdc. Housing in anodized aluminum alloy. Installation on mast ∅ 40 mm external and ∅ 36 mm internal. Input with 19-
pole M23 male connector and 19-pole M23 female free connector. The HD52.3D-S software, for instrument configuration
and monitor, downloadable from Delta OHM website is included. CP51… cable on request.

ACCESSORIES FOR HD51.3D... ANEMOMETERS


HD52.3D-S CD-ROM with HD52.3D-S software for PC connection, instrument configuration and monitor. For Windows® operating 50
systems. The CD also includes a software for the Modbus connection to PC.
RS51K Kit for connecting the anemometer RS485 auxiliary output to a PC. It includes the SWD10 power supply and the 114
RS485/USB adapter with: screw terminals for the connection to the CP51… cable (not included), USB connector for the
connection to the PC, jack connector for connecting the SWD10 power supply.
HD52.30K Birds spikes for HD52.3D…. and HD51.3D…. 125
CP51.5 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 5 m. 105
CP51.10 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 10 m. 145
CP51.15 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 15 m. On request
CP51.20 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 20 m. On request
CP51.30 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 30 m. On request
CP51.50 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 50 m. On request
CP51.75 Connecting cable with 19-pole M23 female connector on one side, open wires on the other side. L = 75 m. On request

13
MODEL CUP ANEMOMETERS
HD54.3 3-cup anemometer. Measuring range: 1...75 m/s. Output signal: sine wave with frequency linearly On request
proportional to wind speed, typical peak to peak amplitude 12 V @ 60 Hz. Operating temperature:
-45...+60 °C. Installation on a mast. Height 81 mm once assembled. With cable CPM12AA4.5 (L=5 m).

WIND DIRECTION VANE PROBES


HD54.D Wind direction vane probe. Measuring range: 0…360°. Deadband: typical 4°, maximum 8°. On request
Threshold: 1m/s. Output signal: DC voltage from potentiometer. Working temperature/humidity:
-40…+60 °C / 0…100% RH. Installation on a mast. Dimensions: 210 x 120 mm. With cable
CPM12AA4.5 (L=5 m).

ACCESSORIES FOR HD54.3 AND HD54.D

HD54.9K Crossbar pole kit including: 195


• cross bar ∅ 40 mm and L=1500 mm;
• two extension bars ∅ 40 mm;
• fixing accessories.

14
MODEL HD32MT.1 PROGRAMMABLE DATALOGGER EURO

HD32MT.1 Programmable datalogger able to capture and store the values measured by a series of sensors connected to its inputs. 1568
• 8 analog channels. Each channel can be used as differential input or alternatively as two single-ended inputs.
• 8 digital I/O. Eight digital ports, each configurable as input from a sensor or alarm output.
• 2 inputs to count the number of pulses or to measure the frequency of signals (max 50KHz). TTL logic levels,
minimum pulse width 10µs.
• 2 isolated inputs to count the number of switching or to measure the switching frequency of a voltage-free contact.
• 1 RS485 port.
• 2 RS232 ports. One port for connecting the PC or the Radio Modem (optional) and one port for connecting the GSM
module (optional).
• 2 alarm outputs with isolated voltage-free contacts.
• 1 auxiliary output +5V, max 500mA.
• 1 switched output Vsw active during the acquisition of the measures.
• Power supply: 12÷30Vdc. Power consumption: 40mA @ 12Vdc.
• Acquisition interval from 2 s to 24 hours.
• Memory size: 4 MB and SD card (up to 4 GB) reader.
• Operating temperature and humidity: -40÷60°C, 0÷95% RH no condensing.
• Housing: anodized and painted aluminum.
• Dimensions: 222 x 140 x 63 mm.
• Weight: 1 kg.
It includes HD32MTLogger software downloadable from Delta OHM website.
Supplied with: SD card, instruction manual. Sensors, cables, GSM module and solar panel have to be ordered
separately. The Radio Modem option must be requested when ordering.

ACCESSORIES FOR HD32MT.1


HD32MTLogger CD-ROM with software HD32MTLogger for programming, data download, monitor and PC data management. For 50
Windows® operating systems.
HD32MT.ALM Sensor which indicates the opening of the housing door. 90
HD53GSM Quad-band wireless GSM/GPRS module (GSM850, GSM900, DCS1800, PCS1900). Equipped with slot for 1.8V and 3V 198
SIM cards, SMA connector for the antenna, power supply connector with remote on/off line, RS232 Sub-D connector
and LED status indicators. Output power: class 4 (2W) @ GSM850 and GSM900, class 1 (1W) @ DCS1800 and
PCS1900. Power supply 8÷28Vdc. Operating temperature: -35÷+80°C. Supplied with whip antenna and standard RS232
serial cable. (SIM card not included)
HD5320.E Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 900/2100 MHz 198
module (for use in Europe, SIM card not included).
HD5320.E.GPS Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 900/2100 MHz 209
module (for use in Europe, SIM card not included). With GPS option to automatically update the clock of the data
logger and identify the installation site.
HD5320.U Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 850/1900 MHz 198
module (for use in U.S.A. and Canada, SIM card not included).
HD5320.U.GPS Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 850/1900 MHz 209
module (for use in U.S.A. and Canada, SIM card not included). With GPS option to automatically update the clock of
the data logger and identify the installation site.
HD5320.J Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 850/2100 MHz 198
module (for use in Japan, SIM card not included).
HD5320.J.GPS Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 850/2100 MHz 209
module (for use in Japan, SIM card not included). With GPS option to automatically update the clock of the data logger
and identify the installation site.
HD5110 RS232 to ETHERNET adapter. Power supply: 12...48 Vdc. Power consumption: 128,7 mA @ 12 Vdc. Operating On request
temperature: 0...+55°C. RS232 connector: DB9 male. ETHERNET connector: RJ-45 female.
HD5150 RS232/RS422/RS485 to ETHERNET adapter. Power supply: 12…48 Vdc. Consumption: 200 mA @ 12 Vdc. Operating On request
temperature: 0…+55 °C. RS232/RS422/RS485 connector: DB9 male. ETHERNET connector: RJ-45 female.
HDF2414 WCDMA/HSDPA/HSUPA IP modem, including whip antenna and serial port. Power supply 5...35 Vdc. Terminal block 326
connection. (SIM card not included)
HDMB3180 “Modbus Gateway” RS232 to ETHERNET adapter. Converts from Modbus-RTU to Modbus-TCP/IP. Power supply: 508
12…48 Vdc. Operating temperature: 0…+60 °C. RS232 connector: DB9 male. ETHERNET connector: RJ-45 female.
HDRMO169 VHF radio modem module pair, frequency 169MHz, including whip antenna and RS232 serial port. Already configured On request
for connection to the logger and the PC (the two modules are not interchangeable). The modules only work with the
version of the data logger with radio modem option.
HDTCF-142-M RS232/RS485 to optical fiber adapter. Power supply: 12…48 Vdc. Consumption: 140 mA @ 12 Vdc. Operating On request
temperature: 0…+60 °C. RS232/RS485 terminal block connection. Optical fiber connector: SC or ST (to be specified
when ordering). Type of optical fiber: multi-mode.
HD7520R RS232/RS485 adapter. Power supply: 10…30 Vdc. Consumption: 1.2 W. Operating temperature: -25…+75 °C. RS232 248
connector: DB9 female. RS485 terminal block connection. Isolated RS485 side. 35 mm DIN rail installation.
9CPRS232 Null modem cable with 9-pin Sub-D female connector on both sides. For the connection of the data logger to the PC 15
RS232C port.
C.205 Connection cable with USB connector on PC side and sub-D 9-pole female connector on data logger side. The cable has 70
a built-in RS232/USB converter and connects the data logger directly to the USB port of the PC.
C.205M Connection cable with USB connector on PC side and sub-D 9-pole male connector on Radio Modem side. The cable has 70
a built-in RS232/USB converter and connects the Radio Modem directly to the USB port of the PC.
CP25 Serial connection cable with USB connector on the PC side and 8-pole M12 female connector on the outdoor housing 70
side. The cable has a built-in USB/RS232 converter and connects the HD32.35, HD32.35FP, HD32.36 and HD32.36FP
outdoor housings to the PC USB port.

15
MODEL ACCESSORIES FOR HD32MT.1 EURO

HD32.35 HD32MT.1 data logger integrated in an AISI 304 stainless steel outdoor housing. Screen to protect the housing from 2686
solar radiation. Powder-coated white. Double locking, one is a key. Dimensions 450 x 300 x 210 mm. IP66 protection
degree. Supplied with accessories for attachment to the pole diameter 36 ÷ 52 mm. Provided for 100 ÷ 240 Vac mains
power supply, includes: HD32MT.1 data logger, AC/DC power supply unit with integrated battery charger, 12V
rechargeable backup battery, surge protectors, disconnectors, terminal block for power supply distribution and connectors
for connecting the external sensors. Wired and tested.

A = Backup battery
B = RS485 surge protector
C = Data logger
D = Door opening alarm
(optional)
E = GSM module (optional)
F = Radio Modem (optional)
G = Barometric transmitter
(optional)
H = Terminal block
I = Power supply unit
J = Fuse
K = Disconnector
L = Power supply surge
protector
M = Terminal block
N = Documentation holder

HD32.35FP HD32MT.1 data logger integrated in an AISI 304 stainless steel outdoor housing. Screen to protect the housing from 2481
solar radiation. Powder-coated white. Double locking, one is a key. Dimensions 450 x 300 x 210 mm. IP66 protection
degree. Supplied with accessories for attachment to the pole diameter 36 ÷ 52 mm. Provided for power supply from
solar panel, includes: HD32MT.1 data logger, solar charge controller, terminal block for power supply distribution and
connectors for connecting the external sensors. Wired and tested.

A = GSM module (optional)


B = Radio Modem (optional)
G = Barometric transmitter
(optional)
D = Data logger
E = Charge controller
F = RS485 surge protector
G = Terminal block
H = Terminal block
I = Door opening alarm
(optional)
L = Documentation holder

HD32.36 HD32MT.1 data logger integrated in a fiberglass-reinforced hot-pressed polyester outdoor housing. Screen to protect 2450
the housing from solar radiation, powder-coated anodized aluminum. White. Key lock. Dimensions 415 x 310 x 170 mm.
IP66 protection degree. Supplied with accessories for attachment to the stainless steel pole diameter 36 ÷ 52 mm.
Provided for 100 ÷ 240 Vac mains power supply, includes: HD32MT.1 data logger, AC/DC power supply unit with
integrated battery charger, 12V rechargeable backup battery, surge protectors, disconnectors, terminal block for power
supply distribution and connectors for connecting the external sensors. Wired and tested.

A = Backup battery
B = RS485 surge protector
C = Data logger
D = Door opening alarm
(optional)
E = GSM module (optional)
F = Radio Modem (optional)
G = Barometric transmitter
(optional)
H = Terminal block
I = Power supply unit
J = Fuse
K = Disconnector
L = Power supply surge
protector
M = Terminal block

16
MODEL ACCESSORIES FOR HD32MT.1 EURO

HD32.36FP HD32MT.1 data logger integrated in a fiberglass-reinforced hot-pressed polyester outdoor housing. Screen to protect 2245
the housing from solar radiation, powder-coated anodized aluminum. White. Key lock. Dimensions 415 x 310 x 170 mm.
IP66 protection degree. Supplied with accessories for attachment to the stainless steel pole diameter 36 ÷ 52 mm.
Provided for power supply from solar panel, includes: HD32MT.1 data logger, solar charge controller, terminal block
for power supply distribution and connectors for connecting the external sensors. Wired and tested.

A = GSM module (optional)


B = Radio Modem (optional)
G = Barometric transmitter
(optional)
D = Data logger
E = Charge controller
F = Terminal block
G = Terminal block
H = RS485 surge protector
I = Door opening alarm
(optional)

HD32.D LCD viewer designed for being fixed on outdoor housings HD32.35,
HD32.35FP, HD32.36 and HD32.36FP.
190

HD32.D.GPS LCD viewer designed for being fixed on outdoor housings HD32.35, 215
HD32.35FP, HD32.36 and HD32.36FP. With GPS module for automatical
time synchronization of the data logger.

DISPLAY

HD32.VACFV Option outdoor housing provided for dual power supply: from mains 100 ÷ 240 Vac and from solar panel. + 240

EDUCATION COURSE

4 hours course on the functions of the instrument, measurement applications, modem and data logger configuration. Elements of theory when 500
necessary.

INSTALLATION OF OUTDOOR HOUSING

HOUSING
SOLAR
RADIATION
SHIELD

17
MODEL HD32MT.3 DATA LOGGER EURO

HD32MT.3K Datalogger in housing for outdoor use made of hot-pressed polyester reinforced with fiberglass, key lock, protection shield from 1540
solar radiation, 12 V / 7 Ah rechargeable backup battery, battery charger, LCD display. IP 66 protection degree.
The data logger has:
• an SDI-12 port, to which you can connect up to four sensors;
• an RS485 port with Modbus-RTU protocol designed for the connection of Delta OHM sensors;
• three configurable analog inputs for connecting transmitters with analog output 0…1 V, 0…10 V, 0…20 mA
or 4…20 mA;
• an input for connecting a rain gauge with potential-free contact output;
• an input for the connection of a cup anemometer with contact output or sinusoidal analog output;
• a potentiometer input for connection of a wind vane for measuring wind direction or for connection of other
sensors with potentiometric output;
• an insulated voltage-free contact alarm output.
Inside the housing it is also possible to place an optional atmospheric pressure and temperature sensor (to be requested
when ordering).
Data recording on SD card for a long lasting registration.
An optional GSM/UMTS module allows sending logged data via e-mail, FTP and to Delta OHM Cloud, and alarm
SMS once the settled measuring thresholds have been exceeded. The GSM/UMTS module allows keeping the clock of
the data logger automatically updated. If the module is installed, a connection via Internet to the data logger from a
remote server is possible, by means of a direct TCP/IP connection.
Data logger power supply: 17…26 Vdc.
It can be powered from 100…240 Vac mains by using the optional AC/DC external power supply unit HD32MT.SWD.
For power supply from solar panel, it is required a 18 Ah backup battery instead of 7 Ah (order the code HD32MT.3K1).
It includes Meteo Studio software downloadable from Delta OHM website. Supplied with: housing fixing accessories, CP22
USB connecting cable, 4 GB SD memory card, operating manual.

HD32MT.3BK HD32MT.3K data logger equipped with an internal barometric sensor. Measuring range 600…1100 hPa. 1549
HD32MT.3K1 Like HD32MT.3K but with 18 Ah backup battery instead of 7 Ah, for power supply from solar panel. 1595
HD32MT.3BK1 HD32MT.3K1 data logger equipped with an internal barometric sensor. Measuring range 600…1100 hPa. 1601

OPTIONAL COMMUNICATION MODULES FOR HD32MT.3

HD5320.E Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 900/2100 MHz 198
module (for use in Europe, SIM card not included).
HD5320.U Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 850/1900 MHz 198
module (for use in U.S.A. and Canada, SIM card not included).
HD5320.J Quad-band GSM/GPRS/EDGE (GSM850, EGSM900, DCS1800, PCS1900) and dual-band UMTS/HSDPA 850/2100 MHz 198
module (for use in Japan, SIM card not included).
HD5110 RS232 to ETHERNET adapter. Power supply: 12...48 Vdc. Power consumption: 128,7 mA @ 12 Vdc. Operating 168
temperature: 0...+55°C. Dimensions: 52 x 80 x 22 mm. RS232 connector: DB9 male. ETHERNET connector: RJ-45
female.

ACCESSORIES FOR HD32MT.3

Meteo Studio CD-ROM with software Meteo Studio for programming the HD32MT.3 data logger, data download, monitor and PC data 50
management. For Windows® operating systems.
HD32MT.ALM Sensor which indicates the opening of the housing door. 90
HD32MT.SWD 100…240 Vac / 24 Vdc power supply unit with switch. Wall-mount or attachment on a ∅ 40 mm mast (to be specified 267
when ordering). Includes the fixing accessories.
HD2004.30K Kit to mount photovoltaic panel 30 W 675x350x35mm on mast ∅ 40÷50 mm. AISI 304 steel. 106
PFV.30W 30 W monocrystalline photovoltaic panel. Dimensions 675 x 350 x 35 mm. (Shipment only in Italy) on request
HD2005.20 Tripod kit with adjustable legs for installing environmental sensors (anemometers, pyranometers, temperature and 290
humidity, etc.). Material: anodized aluminum. Max. height 2 m. It can be fixed on a flat base with screws or to the ground
with pegs. Foldable legs for the transport.
HD2005.20.1 Tripod kit with adjustable legs for installing environmental sensors (anemometers, pyranometers, temperature and 335
humidity, etc.). Material: anodized aluminum. Max. height 3 m. It can be fixed on a flat base with screws or to the ground
with pegs. Foldable legs for the transport.

ATTENTION: The addition of optional sensors may require, depending on the type of sensors, the use of the HD2004.30 80 W solar panel (1200x530x34
mm), HD2004.22K fixing kit and 75 Ah backup battery to be accommodated in a place protected against weather agents, hot and cold.

18
19
WIRELESS DATA LOGGING
SYSTEM OVERVIEW

Sensors

HD35ED series HD33 series


Data loggers GSM/GPRS/3G
Pag. 24 Data Loggers
Pag. 39

HD35AP series
Base units
“Access Points”
Pag. 21

Database
Server PLC
PC

20
HD35…
WIRELESS DATA LOGGING SYSTEM

MODEL HD35AP… BASE UNITS EURO

ATTENZIONE:
THE PRICES OF THE BASE UNITS REFER TO THE MODELS HD35AP….E
(868 MHz) AND HD35AP….U (902-928 MHz).
FOR THE MODELS HD35AP….J (915.9-929.7 MHz), YOU MUST ADD 25 €.

HD35APW Base unit for interfacing among PC and data loggers of the system. USB connection. Wi-Fi 360
USB + Wi-Fi + interface for the connection to the wireless local network (LAN) and ETHERNET interface
ETHERNET for the cable connection to the local network (LAN); allows the use of the MODBUS
TCP/IP protocol. It sends (if connected to Internet via Wi-Fi or Ethernet) alarm e-mails and
recorded data via e-mail, via FTP and to an HTTP server (Cloud). Powered by the PC
USB port or external power adapter SWD06 (optional). It includes HD35AP-S software
downloadable from Delta OHM website. The unit is supplied with: internal lithium-ion
rechargeable battery HD35-BAT1, wall mount support HD35.03, operating manual. The
USB cable CP31, the external power adapter SWD06 (it is required for LAN operation)
and the kit HD35.11K (pair of flanges, pin for padlock and padlock) for fixed installation
have to be ordered separately.

HD35APS Base unit for interfacing among PC and data loggers of the system. USB connection and 270
USB + RS485 output with MODBUS-RTU protocol. Powered by the PC USB port or external
RS485 ModBus-RTU power adapter SWD06 (optional). It includes HD35AP-S software downloadable from
Delta OHM website. The unit is supplied with: internal lithium-ion rechargeable battery
HD35-BAT1, wall mount support HD35.03, operating manual. The USB cable CP31, the
external power adapter SWD06 and the kit HD35.11K (pair of flanges, pin for padlock
and padlock) for fixed installation have to be ordered separately.

HD35APR Base unit for interfacing among PC and data loggers of the system. For 35 mm DIN rail. 365
USB + USB connection, RS485 output with MODBUS-RTU protocol and ETHERNET interface
RS485 ModBus-RTU for the cable connection to the local network; allows the use of the MODBUS TCP/IP
+ ETHERNET protocol. It sends (if connected to Internet via Ethernet) alarm e-mails and recorded data
via e-mail, via FTP and to an HTTP server (Cloud). External power supply 8…30 Vdc
(the unit has no internal battery). It includes HD35AP-S software downloadable from Delta
OHM website. The USB cable CP31 has to be ordered separately.
HD35APG Base unit for interfacing among PC and data loggers of the system. USB connection. 345
USB + GSM module Integrated GSM module for sending alarm e-mail or SMS and recorded data via e-mail,
via FTP and to an HTTP server (Cloud). Allows the communication with the PC through
the GPRS TCP/IP protocol. SMS messages can be sent to the base unit, to control the GSM
functions of the unit. Powered by the PC USB port or external power adapter SWD06
(optional). It includes HD35AP-S software downloadable from Delta OHM website. The
unit is supplied with: internal lithium-ion rechargeable battery HD35-BAT1, basic
HD35AP-S software, wall mount support HD35.03, operating manual. The USB cable
CP31, the external power adapter SWD06 (it is required for GSM operation) and the kit
HD35.11K (pair of flanges, pin for padlock and padlock) for fixed installation have to be
ordered separately.
HD35AP3G Like HD35APG but with 3G functionality in addition. 399
USB + 3G module

HD35AP Base unit for interfacing among PC and data loggers of the system. USB connection. 250
USB Powered by the PC USB port or external power adapter SWD06 (optional). It includes
HD35AP-S software downloadable from Delta OHM website. The unit is supplied with:
internal lithium-ion rechargeable battery HD35-BAT1, basic HD35AP-S software, wall
mount support HD35.03, operating manual. The USB cable CP31, the external power
adapter SWD06 and the kit HD35.11K (pair of flanges, pin for padlock and padlock) for
fixed installation have to be ordered separately.

HD35APD “Dongle” base unit for interfacing among PC and data loggers of the system. USB 108
USB connection. Powered only by the PC USB port (the unit has no internal battery). Internal
antenna. It includes HD35AP-S software downloadable from Delta OHM website.

HD35APGMT Base unit in IP 65 housing for outdoor. USB connection. Integrated GSM module for 590
USB + GSM module sending alarm e-mail or SMS and recorded data via e-mail, via FTP and to an HTTP
server (Cloud). Allows the communication with the PC through the GPRS TCP/IP
protocol. SMS messages can be sent to the base unit, to control the GSM functions of the
unit. 18…27 Vdc power supply (from a 12 V solar panel, not included). It includes
HD35AP-S software downloadable from Delta OHM website. The unit is supplied with:
internal 12 V rechargeable lead battery, charge regulator, operating manual. The USB
cable CP31 and the clamping HD2003.77/40 for the mast installation have to be ordered
separately.

HD35AP3GMT Like HD35APGMT but with 3G functionality in addition. 620


USB + 3G module

21
HD35AP… BASE UNITS ORDERING CODES

HD35AP .

TYPE OF CONNECTION: RADIO FREQUENCY:


Blank = USB only E = 868 MHz (Europe)
D = USB only, dongle version U = 902-928 MHz (U.S.A. and Canada). Reducible to:
R = USB + RS485 (Modbus-RTU) + ETHERNET 915-928 MHz (Australia) or 921.5-928 MHz (New Zealand)
S = USB + RS485 (Modbus-RTU) J = 915.9-929.7 MHz (Japan, not for HD35APD and HD35APG…)
W = USB + Wi-Fi + ETHERNET Other frequencies on request.
G = USB + GSM
3G = USB + 3G/GSM
GMT = USB + GSM (for outdoor)
3GMT = USB + 3G/GSM (for outdoor)

22
HD35AP… CONNECTIONS
USB ETHERNET
Available in all HD35AP… models With proprietary or Modbus TCP/IP protocol
Available in HD35APR and HD35APW

Wi-Fi GSM - Available in HD35APG and HD35APGMT


Available in HD35APW 3G/GSM - Available in HD35AP3G and HD35AP3GMT

RS485 MODBUS-RTU
Available in HD35APS and HD35APR

23
HD35ED… DATA LOGGERS
MODEL
FOR ENVIRONMENTAL ANALYSIS
HD35EDW… Wireless data logger in IP 67 waterproof housing. Front dimensions 120x80 mm. It stores the measures in its internal memory and
transmits the logged data to the base unit automatically at regular intervals or upon request. Optional LCD display. Transmitting range in
open field: 300 m (E, J) / 180 m (U) with internal antenna, >500 m (E, J, U) with external antenna. Acoustic alarm with internal buzzer.
Powered by the internal battery (except the model with RS485 Modbus-RTU input).
It can be wall mounted by means of the optional HD35.24W flange or fixed on a 40 mm diameter mast by means of the HD2003.77/40
clamping (optional). Optional protection shield from solar radiations.
Supplied with: internal 3.6V not rechargeable lithium-thionyl chloride (Li-SOCl2) battery (except the model with RS485 Modbus-RTU
input) and operating manual.
The radio frequency (868 MHz: option E, 902-928 MHz: option U or 915.9-929.7 MHz: option J) has to be specified when
ordering.

HD35ED W .
ANTENNA AND SOLAR RADIATIONS SHIELD:
Blank = internal antenna (without shield and clamping) (*)
W = fixed external antenna (without shield and clamping)
X = fixed external antenna + shield and clamping
Y = external antenna with 3 m cable (without shield and clamping)
Z = external antenna with 3 m cable + shield and clamping
(*)
Option not available in HD35ED…J models.

RADIO FREQUENCY:
E = 868 MHz (Europe)
U = 902-928 MHz (U.S.A. and Canada). Reducible to:
915-928 MHz (Australia) or 921.5-928 MHz (New Zealand)
J = 915.9-929.7 MHz (Japan)
Other frequencies on request.

PROBE TYPE:
H = terminal header inputs for standard analog sensors
-MB = input for RS485 Modbus-RTU sensors
TC = probe with cable
TV (or TVI) = fixed vertical probe without cable

MEASURED QUANTITIES:
The available combinations of quantities are those listed in this price
list. Other models can be supplied upon request.
1 = humidity
4b = atmospheric pressure (barometer)
N = temperature NTC10K sensor
7P = temperature Pt100/Pt1000 sensor
P = rainfall quantity
R = solar radiation (pyranometer)
S = soil volumetric water content
L = leaf wetness
D = level
Blank = analog or RS485 Modbus-RTU standard sensors

LCD:
Blank = without LCD
L = with custom LCD

24
HD35ED… DATA LOGGERS FOR ENVIRONMENTAL ANALYSIS
ATTENTION:
THE PRICES LISTED REFER TO THE MODELS HD35ED….E (868 MHz) AND HD35ED….U (902-928 MHz)
WITHOUT DISPLAY AND WITH INTERNAL ANTENNA. TO THE PRICES LISTED, YOU MUST ADD:
41 € FOR THE DISPLAY
33 € FOR THE OPTION W: Fixed external antenna (without shield and clamping)
84 € FOR THE OPTION X: Fixed external antenna + HD9217TF1 solar shield + HD2003.77/40 clamping
64 € FOR THE OPTION Y: External antenna with cable (without shield and clamping)
112 € FOR THE OPTION Z: External antenna with cable + HD9217TF1 solar shield + HD2003.77/40 clamping
FOR THE MODELS HD35ED….J (915.9-929.7 MHz), YOU MUST ADD 33 €.

MODELS WITH CUSTOM LCD MODELS WITHOUT LCD


HD35EDLW… HD35EDW…

FIXED EXTERNAL ANTENNA EXTERNAL ANTENNA


HD9217TF1 SOLAR SHIELD WITH 3 m CABLE
HD2003.77/40 CLAMPING FOR FIXING TO A ∅ 40 mm MAST AND STAINLESS STEEL CLAMP
FOR FIXING TO A
∅ 40…60 mm MAST

25
HD35ED… DATA LOGGERS FOR ENVIRONMENTAL ANALYSIS

MEASUREMENTS INPUTS

Number of
Built-in
Pag.
MODEL M12
sensors
NTC Pt100 Solar Air Air connectors
TC RH Patm PYRA Rain Leaf
10K Pt1000 panel speed direct.

HD35EDW1NTC • • 1 27

HD35EDW17PTC • • 1 27

HD35EDW1NTV • • • 27
Sensor integrated
HD35EDW1NTVI
in RH module • • 27

HD35EDW14bNTC • • • 1 Patm 28

HD35EDW14b7PTC • • • 1 Patm 28

HD35EDWRTC • 1 28

HD35EDW1NRTC • • • 2 28

HD35EDW7PRTC • • 2 29

HD35EDW1N7PRTC • • • • 3 29

HD35EDWRPTC • • 2 29

HD35EDWPTC • 1 29

HD35EDWPTC-ALM • 1 30

HD35EDWNPTC • • 2 30

HD35EDW1NPTC • • • 2 30

HD35EDW1NLTC • • • 2 30

HD35EDWSTC 1 31
Soil temperature and
HD35EDWS/2TC
volumetric water content
2 31

HD35EDWS/3TC 3 31
Level 1
HD35EDWDPTC
(*) • +cable gland
31

Transmitters with 0÷20 mA, 4÷20 mA, 0÷50 mV, 0÷1 V or 0÷10 V output
HD35EDWH Pt100 / Pt1000 Sensors, K, J, T, N, E thermocouples 4 terminal inputs 32
Sensors with voltage-free contact or potentiometric output
Sensors with RS485 Modbus-RTU output
HD35EDW-MB
One sensor with voltage-free contact output (tipping bucket rain gauge)
terminal inputs 32

HD35EDMTC • • • • • • • 5 Patm 33

(*) Measurement of pressure relative to the atmosphere for the calculation of a fluid level (e.g. water).

26
MODEL TEMPERATURE AND HUMIDITY
DESCRIPTION EURO
HD35EDW1NTC Temperature and humidity wireless data logger. 24,000 samples. Optional custom LCD 191
display (option L). One input with M12 connector for the HP3517WTC... temperature
and relative humidity combined probe (with NTC10KΩ temperature sensor).
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The temperature / R.H. combined probe of the
HP3517WTC… series has to be ordered separately.

HD35EDW17PTC Temperature and humidity wireless data logger. 24,000 samples. Optional custom LCD 196
display (option L). One input with M12 connector for the HP3517ETC... temperature and
relative humidity combined probe (with Pt100 temperature sensor, extended temperature
range).
Sensors measuring ranges:
temperature: -40…+150 °C
relative humidity: 0…100% RH
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The temperature / R.H. combined probe of the
HP3517ETC… series has to be ordered separately.

HD35EDW1NTV Temperature and humidity wireless data logger. 24,000 samples. Optional custom LCD 287
display (option L). Fixed vertical probe (with NTC10KΩ temperature sensor).
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
R.H. sensor operating temperature: -20…+80 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters).

HD35EDW1NTVI Temperature and humidity wireless data logger. 24,000 samples. Optional custom LCD 277
display (option L). Fixed vertical probe (with temperature sensor integrated in the R.H.
module).
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
R.H. sensor operating temperature: -40…+105 °C (R.H.max=[100-2*(T-80)]
@ T=80…105 °C).
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters).

THE PRICES REFER TO THE MODELS WITHOUT DISPLAY.


FOR THE EXTRA CHARGE OF THE DISPLAY OPTION, PLEASE SEE PAG. 25.

27
MODEL TEMPERATURE, HUMIDITY AND ATMOSPHERIC PRESSURE
DESCRIPTION EURO
HD35EDW14bNTC Temperature, humidity and atmospheric pressure wireless data logger. 22,000 samples. 308
Optional custom LCD display (option L). One input with M12 connector for the
HP3517WTC... temperature and relative humidity combined probe (with NTC10KΩ
temperature sensor). Integrated pressure sensor.
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
atmospheric pressure: 300…1100 hPa
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The temperature / R.H. combined
probe of the HP3517WTC… series has to be ordered separately.
HD35EDW14b7PTC Temperature, humidity and atmospheric pressure wireless data logger. 22,000 samples. 328
Optional custom LCD display (option L). One input with M12 connector for the
HP3517ETC... temperature and relative humidity combined probe (with Pt100 temperature
sensor, extended temperature range). Integrated pressure sensor.
Sensors measuring ranges:
temperature: -40…+150 °C
relative humidity: 0…100% RH
atmospheric pressure: 300…1100 hPa
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The temperature / R.H. combined
probe of the HP3517ETC… series has to be ordered separately.

SOLAR RADIATION
DESCRIPTION EURO
HD35EDWRTC Solar radiation quantity wireless data logger. 42,000 samples. Optional custom LCD 221
display (option L). One input with M12 connector for the pyranometer.
Solar radiation measuring range: 0…2000 W/m2.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: daily solar radiation in Wh/m2 (Wh = watt hour).
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The pyranometer has to be ordered
separately. Secondary standard, first class or second class pyranometers are
available.

TEMPERATURE, HUMIDITY AND SOLAR RADIATION


DESCRIPTION EURO
HD35EDW1NRTC Temperature, humidity and solar radiation wireless data logger. 24,000 samples. Optional 308
custom LCD display (option L). Two inputs with M12 connector: one for the
HP3517WTC… temperature and relative humidity combined probe (with NTC10KΩ
temperature sensor), and one for the pyranometer LPPYRA03.
Instrument measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
solar radiation: 0…2000 W/m2
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, absolute humidity, daily solar radiation in Wh/m2 (Wh
= watt hour).
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The HP3517WTC… temperature / R.H.
combined probe and the LPPYRA 03 pyranometer have to be ordered separately.

THE PRICES REFER TO THE MODELS WITHOUT DISPLAY.


FOR THE EXTRA CHARGE OF THE DISPLAY OPTION, PLEASE SEE PAG. 25.

28
MODEL SOLAR RADIATION AND SOLAR PANEL TEMPERATURE
DESCRIPTION EURO
HD35EDW7PRTC Solar radiation and solar panel temperature wireless data logger. 36,000 samples. 277
Optional custom LCD display (option L). Two inputs with M12 connector: one for the
TP35878ISS... Pt100 temperature probe for solar panel, and one for the pyranometer.
Instrument measuring ranges:
temperature: -40…+85 °C
solar radiation: 0…2000 W/m2
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: daily solar radiation in Wh/m2 (Wh = watt hour).
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The TP35878ISS... temperature probe for solar
panel and the pyranometer have to be ordered separately.

TEMPERATURE, HUMIDITY, SOLAR RADIATION


AND SOLAR PANEL TEMPERATURE
DESCRIPTION EURO
HD35EDW1N7PRTC Environmental temperature, humidity, solar radiation and solar panel temperature 323
wireless data logger. 22,000 samples. Optional custom LCD display (option L). Three
inputs with M12 connector: one for the HP3517WTC… temperature and relative humidity
combined probe (with NTC10KΩ temperature sensor), one for the pyranometer and one for
the TP35878ISS... Pt100 temperature probe for solar panel.
Instrument measuring ranges:
environmental temperature: -40…+105 °C
relative humidity: 0…100% RH
solar radiation: 0…2000 W/m2
solar panel temperature: -40…+85 °C
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, absolute humidity, daily solar radiation in Wh/m2 (Wh
= watt hour).
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The HP3517WTC… temperature / R.H.
combined probe, the pyranometer and the TP35878ISS... temperature probe for solar
panel have to be ordered separately.

SOLAR RADIATION AND RAINFALL QUANTITY


DESCRIPTION EURO
HD35EDWRPTC Solar radiation and rainfall quantity wireless data logger. 28,000 samples. Optional custom 297
LCD display (option L). Two inputs with M12 connector for the pyranometer and the
rain gauge.
Solar radiation measuring range: 0…2000 W/m2.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: daily solar radiation in Wh/m2 (Wh = watt hour), rainfall rate in
mm/h, daily rainfall in mm.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The pyranometer and the rain gauge
have to be ordered separately. The rain gauges HD2013 (area 400 cm2), HD2013R
(area 400 cm2, with heating), HD2015 (area 200 cm2) and HD2015R (area 200 cm2,
with heating) with resolution 0.1 – 0.2 or 0.5 mm, and secondary standard, first
class or second class pyranometers are available.

RAINFALL QUANTITY
DESCRIPTION EURO
HD35EDWPTC Rainfall quantity wireless data logger. 36,000 samples. Optional custom LCD display 226
(option L). One input with M12 connector for the rain gauge.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: rainfall rate in mm/h, daily rainfall in mm.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The the rain gauge has to be ordered
separately. The rain gauges HD2013 (area 400 cm2), HD2013R (area 400 cm2, with
heating), HD2015 (area 200 cm2) and HD2015R (area 200 cm2, with heating) with
resolution 0.1 – 0.2 or 0.5 mm are available.

THE PRICES REFER TO THE MODELS WITHOUT DISPLAY.


FOR THE EXTRA CHARGE OF THE DISPLAY OPTION, PLEASE SEE PAG. 25.

29
MODEL RAINFALL QUANTITY (with alarm contact output)
DESCRIPTION EURO
HD35EDWPTC-ALM Rainfall quantity wireless data logger with alarm contact output and USB output. 36,000 364
samples. Optional custom LCD display (option L). One input with M12 connector for the
rain gauge.
The alarm contact is normally open; the contact closes when an alarm condition occurs
(for example, the contact can be configured to close if the hourly rainfall exceeds a
certain threshold). The alarm contact can trigger an external device for signalling the
alarm. The alarm reset can be configured to be automatical (when the alarm condition
disappears) or manual (by pressing a button for at least 5 seconds); the reset of the alarm
opens the alarm contact.
External 7…30 Vdc power supply. WITHOUT INTERNAL BATTERY.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: rainfall rate in mm/h, daily rainfall in mm.
The the rain gauge has to be ordered separately. The rain gauges HD2013 (area
400 cm2), HD2013R (area 400 cm2, with heating), HD2015 (area 200 cm2) and HD2015R
(area 200 cm2, with heating) with resolution 0.1 – 0.2 or 0.5 mm are available.

RAINFALL QUANTITY AND TEMPERATURE


DESCRIPTION EURO
HD35EDWNPTC Rainfall quantity and temperature wireless data logger. 28,000 samples. Optional custom 297
LCD display (option L). Two inputs with M12 connector for the rain gauge and the
TP350NTC… temperature probe (with NTC10KΩ sensor).
Temperature measuring range: -40…+105 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: rainfall rate in mm/h, daily rainfall in mm.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The TP350NTC… temperature probe and the
rain gauge have to be ordered separately. The rain gauges HD2013 (area 400 cm2),
HD2013R (area 400 cm2, with heating), HD2015 (area 200 cm2) and HD2015R (area
200 cm2, with heating) with resolution 0.1 – 0.2 or 0.5 mm.

RAINFALL QUANTITY, TEMPERATURE AND HUMIDITY


DESCRIPTION EURO
HD35EDW1NPTC Rainfall quantity, temperature and humidity wireless data logger. 22,000 samples. 308
Optional custom LCD display (option L). Two inputs with M12 connector for the rain
gauge and the HP3517WTC… temperature and relative humidity combined probe (with
NTC10KΩ temperature sensor).
Instrument measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, absolute humidity, rainfall rate in mm/h, daily rainfall in
mm.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The HP3517WTC… temperature / R.H.
combined probe and the rain gauge have to be ordered separately. The rain gauges
HD2013 (area 400 cm2), HD2013R (area 400 cm2, with heating), HD2015 (area 200 cm2)
and HD2015R (area 200 cm2, with heating) with resolution 0.1 – 0.2 or 0.5 mm.

TEMPERATURE, HUMIDITY AND LEAF WETNESS


DESCRIPTION EURO
HD35EDW1NLTC Temperature, humidity and leaf wetness wireless data logger. 22,000 samples. Optional 251
custom LCD display (option L). Two inputs with M12 connector: one for the
HP3517WTC… temperature and relative humidity combined probe (with NTC10KΩ
temperature sensor), and one for the leaf wetness sensor HP3501....
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100% RH
leaf wetness: 0…100% wetness
R.H. sensor operating temperature: -40…+150 °C.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: dew point, wet bulb temperature, absolute humidity, mixing ratio,
partial vapour pressure.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30 seconds
logging interval and without repeaters). The HP3517WTC… temperature / R.H.
combined probe and the HP3501... leaf wetness sensor have to be ordered separately.

THE PRICES REFER TO THE MODELS WITHOUT DISPLAY. FOR THE EXTRA CHARGE OF THE DISPLAY OPTION, PLEASE SEE PAG. 25.

30
MODEL SOIL VOLUMETRIC WATER CONTENT AND TEMPERATURE
DESCRIPTION EURO
HD35EDWSTC Soil volumetric water content (VWC) and temperature wireless data logger. 52,000 samples. 211
Optional custom LCD display (option L). One input with M12 connector for the
HP3510... soil volumetric water content and temperature combined probe.
Sensors measuring ranges:
temperature: -40…+60 °C
volumetric water content: 0…100% VWC
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The HP3510... soil volumetric water
content and temperature combined probe has to be ordered separately.

HD35EDWS/2TC Soil volumetric water content (VWC) and temperature wireless data logger. 36,000 samples. 251
Optional custom LCD display (option L). Two inputs with M12 connector for the
HP3510... soil volumetric water content and temperature combined probes.
Sensors measuring ranges:
temperature: -40…+60 °C
volumetric water content: 0…100% VWC
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The HP3510... soil volumetric water
content and temperature combined probes have to be ordered separately.

HD35EDWS/3TC Soil volumetric water content (VWC) and temperature wireless data logger. 26,000 samples. 282
Optional custom LCD display (option L). Three inputs with M12 connector for the
HP3510... soil volumetric water content and temperature combined probes.
Sensors measuring ranges:
temperature: -40…+60 °C
volumetric water content: 0…100% VWC
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The HP3510... soil volumetric water
content and temperature combined probes have to be ordered separately.

LEVEL AND RAINFALL QUANTITY


DESCRIPTION EURO

HD35EDWDPTC Level and rainfall quantity wireless data logger. 28,000 samples. Optional custom LCD 267
display (option L). Two inputs: one with M12 connector for the rain gauge and one with
cable gland for the level sensor. The level is measured with a sensor of pressure relative to
the atmosphere.
Level measuring range: 0…1 bar, corresponding to 0…10 m approx. for water.
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities: rainfall rate in mm/h, daily rainfall in mm.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (2 years typical life with 30
seconds logging interval and without repeaters). The level sensor HP712… and the rain
gauge have to be ordered separately. The rain gauges HD2013 (area 400 cm2),
HD2013R (area 400 cm2, with heating), HD2015 (area 200 cm2) and HD2015R (area
200 cm2, with heating) with resolution 0.1 – 0.2 or 0.5 mm.

THE PRICES REFER TO THE MODELS WITHOUT DISPLAY.


FOR THE EXTRA CHARGE OF THE DISPLAY OPTION, PLEASE SEE PAG. 25.

31
MODEL MODEL WITH TERMINAL HEADER INPUTS FOR STANDARD ANALOG SENSORS
DESCRIPTION EURO
HD35EDWH Wireless data logger with four terminal header inputs for the connection of: 374
- transmitters with 4÷20 mA, 0÷1 / 0÷10 V or 0÷50 mV output
- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples
- sensors with voltage free contact output (max. one sensor)
- potentiometric sensors
Number of samples that can be stored: from 28,000 to 58,000 depending on the number
and type of connected sensors. Optional custom LCD display (option L).
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Supplied with 3.6V non-rechargeable Li-SOCl2 battery (4 years typical life with 30
seconds logging interval and without repeaters).

HD35EDWHE Version for 7...28 Vdc external power supply. WITHOUT INTERNAL BATTERY. 374

MODEL WITH RS485 MODBUS-RTU INPUT


AND CONTACT INPUT FOR RAIN GAUGE
DESCRIPTION EURO
HD35EDW-MB Wireless data logger with RS485 Modbus-RTU input. Allows adding one or more 338
sensors with RS485 Modbus-RTU output (for example an anemometer of the
HD52.3D... series) in the wireless network.
A voltage-free contact input allows connecting a tipping bucket rain gauge.
As an alternative to the Modbus-RTU protocol, a proprietary protocol can be used to
connect the HD2003 anemometer.
Equipped with switched power supply output to power the sensors only when the
measurement has to be carried out.
Number of samples that can be stored: from 14,000 to 52,000 samples depending on the
number of acquired quantities. Optional custom LCD display (option L).
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
7…30 Vdc external power supply. WITHOUT INTERNAL BATTERY.

THE PRICES REFER TO THE MODELS WITHOUT DISPLAY.


FOR THE EXTRA CHARGE OF THE DISPLAY OPTION, PLEASE SEE PAG. 25.

32
MODEL WIRELESS DATA LOGGERS FOR WEATHER STATION EURO

HD35EDMTC Wireless data logger in IP 67 waterproof housing. Front dimensions 120x122 mm. It can measure temperature, 502
humidity, atmospheric pressure, solar radiation, rainfall quantity, wind speed and direction. It stores the measures in its
internal memory (from 28,000 to 58,000 samples depending on the number of detected quantities) and transmits the
logged data to the base unit automatically at regular intervals or upon request. Optional custom LCD display
(option L). Transmitting range in open field: 300 m (E) / 180 m (U) with internal antenna, >500 m (E, U) with
external antenna. Acoustic alarm with internal buzzer. Powered by the internal battery.
Five inputs with M12 connector: one for the HP3517WTC… temperature and relative humidity combined probe (with
NTC10KΩ temperature sensor) or alternatively for the temperature only probe, one for the pyranometer, one for the
rain gauge, one for the HD54.3 cup anemometer and one for the HD54.D wind vane. It is also possible to connect only
some of the probes. Internal barometric sensor.
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100%UR
atmospheric pressure: 300…1100 hPa
solar radiation: 0…2000 W/m2
wind speed: 1…65 m/s
wind direction: 0…359.9°
rainfall: counting of the rain gauge pulses (the resolution depends on the type of rain gauge)
R.H. sensor operating temperature: -40…+150 °C
Instrument operating temperature / humidity: -20…+70 °C / 0…100 % RH.
Calculated quantities (depending on the connected probes): dew point, daily solar radiation in Wh/m2 (Wh = watt hour),
rainfall rate in mm/h, Wind Chill, Wind Gust.
It can be wall mounted or fixed on a 40 mm diameter mast by means of the HD2003.77/40 clamping (optional).
Optional HD32MT4.6 protection shield from solar radiations.
Supplied with BAT-2013DB 3.6V non-rechargeable Li-SOCl2 battery (4 years typical life with 30 seconds logging
interval and without repeaters).
The probes have to be ordered separately.

ANTENNA AND SOLAR RADIATIONS SHIELD:


HD35ED MTC. Blank = internal antenna (without shield and clamping)
W = fixed external antenna (without shield and clamping)
X = fixed external antenna + shield and clamping
Y = external antenna with 3 m cable (without shield and clamping)
Z = external antenna with 3 m cable + shield and clamping

RADIO FREQUENCY:
E = 868 MHz (Europe)
U = 902-928 MHz (U.S.A. and Canada). Reducible to:
915-928 MHz (Australia) or 921.5-928 MHz (New Zealand)
J = 915.9-929.7 MHz (Japan) – Not available

LCD:
Blank = without LCD
L = with custom LCD

33
WIRELESS DATA LOGGERS FOR WEATHER STATION
IN WATERPROOF HOUSING
ATTENTION:
THE PRICE LISTED REFER TO THE MODELS HD35ED….E (868 MHz) AND HD35ED….U (902-928 MHz)
WITHOUT DISPLAY AND WITH INTERNAL ANTENNA. TO THE PRICE LISTED, YOU MUST ADD:
41 € FOR THE DISPLAY
33 € FOR THE OPTION W: Fixed external antenna (without shield and clamping)
84 € FOR THE OPTION X: Fixed external antenna + HD32MT4.6 solar shield + HD2003.77/40 clamping
64 € FOR THE OPTION Y: External antenna with cable (without shield and clamping)
112 € FOR THE OPTION Z: External antenna with cable + HD32MT4.6 solar shield + HD2003.77/40 clamping

MODELS WITH CUSTOM LCD MODELS WITHOUT LCD


HD35EDLM… HD35EDM…

FIXED EXTERNAL ANTENNA EXTERNAL ANTENNA


HD32MT4.6 SOLAR SHIELD WITH 3 m CABLE
HD2003.77/40 CLAMPING FOR FIXING TO A ∅ 40 mm MAST AND STAINLESS STEEL CLAMP
FOR FIXING TO A
∅ 40…60 mm MAST

34
MODEL HD35RE... REPEATER EURO

HD35REW RF signal repeater. Waterproof housing. Powered by the internal battery. Supplied with: 236
internal lithium-thionyl chloride (Li-SOCl2) not rechargeable battery BAT-2013DB,
operating manual. Fixed external antenna.
It can be wall mounted by means of the optional HD35.24W flange or fixed on a Ø 40 mm
mast by means of the HD2003.77/40 clamping (optional). Optional HD9217TF1 protection
shield from solar radiations.

HD35REW.

ANTENNA AND SOLAR RADIATIONS SHIELD (only HD35REW):


W = fixed external antenna (without shield and clamping)
X = with solar radiation shield and clamping
Y = external antenna with 3 m cable (without shield and clamping)
Z = external antenna with 3 m cable + shield and clamping

RADIO FREQUENCY:
E = 868 MHz (Europe)
U = 902-928 MHz (U.S.A. and Canada). Reducible to:
915-928 MHz (Australia) or 921.5-928 MHz (New Zealand)
J = 915.9-929.7 MHz (Japan) – Not available
Other frequencies on request.

ATTENTION:
THE PRICE REFERS TO THE MODELS HD35REW.E (868 MHz) AND HD35REW.U (902-928 MHz).
THE PRICE INCLUDES THE FIXED EXTERNAL ANTENNA.
TO THE PRICE YOU MUST ADD:
51 € FOR THE OPTION X: HD9217TF1 solar shield + HD2003.77/40 clamping (the antenna is always external)
33 € FOR THE OPTION Y: External antenna with cable (without shield and clamping)
80 € FOR THE OPTION Z: External antenna with cable + HD9217TF1 solar shield + HD2003.77/40 clamping

35
MODEL PROBES FOR THE HD35… SERIES EURO

TEMPERATURE AND RELATIVE HUMIDITY COMBINED PROBES


HP3517… Temperature and relative humidity combined probe. Female 4-pole (HP3517WTC…) or 8-pole (HP3517ETC…) M12
connector. R.H. sensor measuring range: 0…100%. R.H.
Accuracy of relative humidity measurement:
± 1.8 %RH (0…85 %RH) / ± 2.5 %RH (85…100 %RH) @ T=15…35 °C.
± (2 + 1.5% measure)% @ T=remaining range.
R.H. sensor operating temperature: -40…+150 °C.
Temperature sensor: NTC10KΩ for HD3517WTC… probes, measuring range: -40…+105 °C;
Pt100 1/3 DIN for HD3517ETC… probes, measuring range: -40…+150 °C.

WTC1.2 WTC1.5 WTC1.10 WTC2.2 WTC2.5 WTC2.10 WTC3.2 WTC3.5 WTC3.10

176 198 237 183 198 248 204 226 264


ETC1.2 ETC1.5 ETC1.10 ETC2.2 ETC2.5 ETC2.10 ETC3.2 ETC3.5 ETC3.10

176 198 237 183 198 248 204 226 264

CABLE LENGTH:
HP3517 .
2 = 2 m, 5 = 5 m, 10 = 10 m

STEM:
TC1 = plastic material, L = 135 mm
TC2 = AISI 304, L = 150 mm
TC3 = plastic material, L = 335 mm

R.H. SENSOR OPERATING TEMPERATURE /


TEMPERATURE SENSOR:
W = -40…+150 °C / NTC10KΩ
E = -40…+150 °C / Pt100

ENVIRONMENTAL TEMPERATURE PROBES


TP350N… Environmental temperature probe. NTC 10KΩ @ 25 °C sensor. Measuring range: -40…+105 °C. Accuracy: ± 0.3 °C
in the range 0…+70 °C / ± 0.4 °C outside.14 mm diameter. Female 4-pole M12 connector.

TC1.2 TC1.5 TC1.10 TC2.2 TC2.5 TC2.10 TC3.2 TC3.5 TC3.10

110 121 143 110 121 143 132 143 165

CABLE LENGTH:
TP350N .
2 = 2 m, 5 = 5 m, 10 = 10 m

STEM:
TC1 = plastic material, L = 135 mm
TC2 = AISI 304, L = 150 mm
TC3 = plastic material, L = 335 mm

Accessories for TP350N… and HP3517… probes

HD9007A-1 12-ring protection from solar radiations. Supplied with mounting bracket. 131
HD9007A-2 16-ring protection from solar radiations. Supplied with mounting bracket. 140
HD9007T26.2 Fitting for Ø 14 mm probes for the protections from solar radiations HD9007A-1 and 18
HD9007A-2.

36
MODEL PROBES FOR THE HD35… SERIES EURO

TEMPERATURE PROBE FOR SOLAR PANEL


TP35878ISS.5 Contact temperature probe for solar panel. 1/3 DIN Pt100 sensor. Temperature working range -40…+85 °C. Cable 106
ending with female 4-pole M12 connector. Cable 5 m.
TP35878ISS.10 Contact temperature probe for solar panel. 1/3 DIN Pt100 sensor. Temperature working range -40…+85 °C. Cable 139
ending with female 4-pole M12 connector. Cable 10 m.

LEAF WETNESS SENSORS


HP3501.5 Leaf wetness sensor with double sensitive surface. IP 67 protection degree. 5 m cable with M12 connector. 145
HP3501.10 Leaf wetness sensor with double sensitive surface. IP 67 protection degree. 10 m cable with M12 connector. 172

SOIL VOLUMETRIC WATER CONTENT AND TEMPERATURE


COMBINED PROBES
HP3510.1.5 Two-electrode probe for the measurement of the soil volumetric water content. With integrated NTC 10 kΩ 117
temperature sensor. M12 connector. 5 m cable.
HP3510.1.10 Two-electrode probe for the measurement of the soil volumetric water content. With integrated NTC 10 kΩ 152
temperature sensor. M12 connector. 10 m cable.

HP3510.2.5 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. With 132
integrated NTC 10 kΩ temperature sensor. M12 connector. 5 m cable.
HP3510.2.10 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. With 172
integrated NTC 10 kΩ temperature sensor. M12 connector. 10 m cable.

LEVEL SENSORS
HP712 Stainless steel level sensor. Measuring principle: detection of the pressure relative to On request
the atmosphere. Measuring range 0…1 bar. Maximum overpressure 4.5 bar.
Operating temperature -20…+80 °C. Protection degree IP 68. Resolution 0.1% f.s.
Accuracy ± 0.8% f.s. @ 25 °C. Cable ended with open wires.

37
MODEL ACCESSORIES FOR THE HD35… SERIES EURO

SWD06 100-240 Vac / 6 Vdc - 1 A mains power adapter. For HD35AP, HD35APW, HD35APG, HD35APS and HD35RE. 45
CP23 Direct USB connection cable with male mini-USB connector on the instrument side and male A type USB connector 15
on the PC side. Cable length 1.5 m. For HD33….
CP31 Direct USB connection cable with male mini-USB connector on the instrument side and male A type USB connector 15
on the PC side. Cable length 1.5 m. For HD35AP… (except HD35APD).

HD35.24W Flange for fixing to the wall the waterproof models HD35EDW... . 25
Specify when ordering on which instruments should be assembled.

HD35.24C Kit including the HD35.24W flange and a clamp for fixing the flange to a ∅ 37
40…50 mm mast.
Specify when ordering on which instruments the flanges should be assembled.

HD35-BAT2 3.6 V lithium-thionyl chloride (Li-SOCl2) non-rechargeable battery, size A, 2-pole Molex 5264 connector. For the 12
data loggers HD35ED….
BAT-2013DB 3.6 V lithium-thionyl chloride (Li-SOCl2) not rechargeable battery, capacity 8400 mAh, size C, Molex 5264 2-pole 36
connector. For the repeater HD35REW and the data loggers HD35EDWK/4TC, HD35EDWH, HD35EDW1NLCT,
HD35EDWS…TC and HD35EDM....

SOFTWARE
HD35AP-S CD-ROM with HD35AP-S basic software for the system configuration, the real time viewing of the measures and 50
the downloading of data in the database. For Windows® operating systems.
HD35AP-CFR21 Advanced version of the HD35AP-S software for the management of the data logging system in accordance with the 1250
FDA 21 CFR part 11 recommendations: traceability of activities (audit trail) performed with the software and
management of users access for the system configuration and viewing of data in the database. It works with USB
hardware key (included).

CLOUD
GHM-CLOUD Service for collecting, on a GHM server, the data sent via internet (with HTTP or FTP protocol) by devices (base
units or data loggers) having a 3G/GSM/GPRS, Wi-Fi or Ethernet connection. The service allows viewing the
collected data by simply using a “Web Browser” and an Internet connection.
The access to the system is via user name and password. Various levels of authorization allow defining users with
different access to the data. Custom configurations for displaying the data can be created.
Free of charge service.

38
MODEL DATA LOGGER WITH GSM/GPRS MODULE FOR WEATHER STATION EURO

HD33M.GSM Wireless data logger in IP 67 waterproof housing. Front dimensions 120x122 mm. It can measure temperature, 543
humidity, solar radiation, rainfall quantity, wind speed and direction. It stores the measures in its internal memory
(from 128,000 to 440,000 samples depending on the number of detected quantities) and transmits the acquired data via
e-mail, via FTP and to an HTTP server (Cloud). USB output. Optional custom LCD display (option L). Acoustic
alarm with internal buzzer and sending of alarm e-mail and SMS.
The GSM functions of the data logger can be controlled remotely by sending SMS messages. A direct GPRS TCP/IP
connection with a remote PC connected to Internet is possible.
Power supply 7…30 Vdc. It can be powered by mains, through the power supply unit HD32MT.SWD, or by a solar
panel, through the power supply unit HD32WSF.S12.
Five inputs with M12 connector: one for the HP3517WTC… temperature and relative humidity combined probe (with
NTC10KΩ temperature sensor) or alternatively for the TP350NTC… temperature only probe, one for the pyranometer,
one for the rain gauge, one for the HD54.3 cup anemometer and one for the HD54.D wind vane. It is also possible to
connect only some of the probes.
Sensors measuring ranges:
temperature: -40…+105 °C
relative humidity: 0…100%UR
solar radiation: 0…2000 W/m2
wind speed: 1…65 m/s
wind direction: 0…359.9°
rainfall: counting of the rain gauge pulses (the resolution depends on the type of rain gauge). A measurement compensation
curve as a function of the rainfall rate can be configured.
R.H. sensor operating temperature: -40…+150 °C. Instrument operating temperature / humidity: -20…+70 °C / 0…100 %
RH.
Calculated quantities (depending on the connected probes): dew point, daily solar radiation in Wh/m2 (Wh = watt hour),
rainfall rate in mm/h, Wind Chill, Wind Gust.
It can be wall mounted or fixed on a 40 mm diameter mast by means of the HD2003.77/40 clamping (optional).
Optional HD32MT4.6 protection shield from solar radiations.
It includes HD35AP-S software downloadable from Delta OHM website.
The probes and the USB cable CP23 have to be ordered separately. SIM card not included.
HD33M4b.GSM HD33M.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 610
300…1100 hPa.

HD33 M .GSM
SOLAR RADIATIONS SHIELD:
W = fixed external antenna (without shield and clamping)
X = fixed external antenna + shield and clamping

PRESSURE SENSOR:
Blank = without internal pressure sensor
4b = with internal pressure sensor

LCD:
Blank = without LCD
L = with custom LCD

ATTENTION:
THE PRICES LISTED REFER TO THE MODELS WITHOUT DISPLAY AND WITH FIXED EXTERNAL
ANTENNA. TO THE PRICES LISTED, YOU MUST ADD:
41 € FOR THE DISPLAY
51 € FOR THE OPTION X: HD32MT4.6 solar shield + HD2003.77/40 clamping (the antenna is always external)

39
MODEL POWER SUPPLY UNITS EURO

HD32MT.SWD 100…240 Vac / 24 Vdc power supply unit with switch. IP 65 housing. Wall-mount or 267
attachment on a ∅ 40 mm mast (to be specified when ordering). Includes the fixing
accessories.

HD32WSF.S12 Solar panel power supply unit with SDI-12 interface for reading the power supply 267
voltage. Includes a 12 Vdc / 7.2 Ah battery and a charge regulator. The power supply
output is the unregulated voltage of the internal battery. IP 65 housing. Wall-mount or
attachment on a ∅ 40 mm mast (to be specified when ordering). Includes the fixing
accessories.

40
DATA LOGGER WITH GSM/GPRS MODULE
MODEL WITH RS485 MODBUS-RTU INPUT EURO
AND CONTACT INPUT FOR RAIN GAUGE

HD33M-MB.GSM Wireless data logger in IP 67 waterproof housing with Master RS485 Modbus-RTU interface for connecting sensors 554
with RS485 Modbus-RTU output (e.g. an anemometer of the HD52.3D… series).
As an alternative to the Modbus-RTU protocol, a proprietary protocol can be used to connect the HD2003
anemometer.
Equipped with a switched power supply output to power the sensors only when the measurement has to be carried out.
The power output, when enabled, has the same value as the power input.
A voltage-free contact input allows connecting a rain gauge. A measurement compensation curve as a function of the
rainfall rate can be configured.
It stores the measures in its internal memory (from 120,000 to 424,000 samples depending on the number of detected
quantities). The data can be sent via e-mail, via FTP and to an HTTP server (Cloud). USB output. Optional custom
LCD display (option L). Sending of alarm e-mail and SMS.
The GSM functions of the data logger can be controlled remotely by sending SMS messages. A direct GPRS TCP/IP
connection with a remote PC connected to Internet is possible.
Power supply 7…30 Vdc. It can be powered by mains, through the power supply unit HD32MT.SWD, or by a solar
panel, through the power supply unit HD32WSF.S12.
Operating conditions: -20…+70 °C / 0…100 % RH.
It can be wall mounted or fixed on a 40 mm diameter mast by means of the HD2003.77/40 clamping (optional).
Optional HD32MT4.6 protection shield from solar radiations.
It includes HD35AP-S software downloadable from Delta OHM website.
The probes and the USB cable CP23 have to be ordered separately.
SIM card not included.

HD33 M-MB.GSM
SOLAR RADIATIONS SHIELD:
W = fixed external antenna (without shield and clamping)
X = fixed external antenna + shield and clamping

LCD:
Blank = without LCD
L = with custom LCD

ATTENTION:
THE PRICES LISTED REFER TO THE MODEL WITHOUT DISPLAY AND WITH FIXED EXTERNAL
ANTENNA. TO THE PRICE LISTED, YOU MUST ADD:
41 € FOR THE DISPLAY
51 € FOR THE OPTION X: HD32MT4.6 solar shield + HD2003.77/40 clamping (the antenna is always external)

41
DATA LOGGER WITH GSM/GPRS MODULE FOR WEATHER STATION
MODEL EURO
WITH INPUTS FOR STANDARD SENSORS
HD33MT.GSM Wireless data logger in IP 65 waterproof housing. Equipped with: 974
• 4 analog independently configurable inputs (0…50 mV, -50…50 mV, 0…1 V, 0…10 V, 0…20 mA or 4…20
mA, Pt100, Pt1000, thermocouple, potentiometer, pyrgeometer).
• 2 voltage-free counting contact inputs (e.g. a tipping bucket rain gauge and a cup anemometer can be connected).
• One RS485 “Master” port with Modbus-RTU protocol.
• One SDI-12 “Master” port compatible with version 1.3 of SDI-12 protocol.
• 2 voltage-free contact alarm outputs.
It stores the measures in its internal memory (from 242,850 to 858,070 samples depending on the number of detected
quantities). The data can be sent via e-mail, via FTP and to an HTTP server (Cloud). USB output. Optional custom
LCD display (option L). Sending of alarm e-mail and SMS.
The GSM functions of the data logger can be controlled remotely by sending SMS messages. A direct GPRS TCP/IP
connection with a remote PC connected to Internet is possible.
Power supply 18…27 Vdc. It can be powered by a solar panel. Optional internal lead-acid rechargeable battery.
Integrated battery charger. The data logger is low power and can operate for weeks even in absence of battery
recharging from the solar panel. A switched power supply output allows powering the sensors only when
measurements have to be taken.
Connecting a rain gauge, the data logger calculates: maximum rainfall rate, daily rainfall, total rainfall and amount of
rainfall which has fallen in the logging interval.
The internal clock of the data logger has high accuracy and is extremely stable in the whole operating temperature
range of the instrument. It can be regularly synchronized with an HTTP or NTP reference server.
Operating conditions: -40…+70 °C / 0…100 % RH.
Housing dimensions 270x170x110 mm. Installation on a Ø 40 mm mast by means of the HD2003.77/40 clamping
(optional). Please specify when ordering whether the housing has to be supplied with the mast clamping already installed.
It includes HD35AP-S software downloadable from Delta OHM website.
The battery, the probes and the USB cable CP23 have to be ordered separately. SIM card not included.
HD33MT4b.GSM HD33MT.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 1076
300…1100 hPa.
HD33MT.3G Like HD33MT.GSM but with 3G/GSM module. 1025
HD33MT4b.3G HD33MT.3G data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 1128
300…1100 hPa.
BAT12V-3.4A 12 V / 3.4 Ah lead-acid rechargeable battery. 42

HD33 MT . COMMUNICATION MODULE:


GSM = with GSM module
3G = with 3G/GSM module

PRESSURE SENSOR:
Blank = without internal pressure sensor
4b = with internal pressure sensor

LCD:
Blank = without LCD
L = with custom LCD

ATTENTION: THE PRICES LISTED REFER TO THE MODELS WITHOUT DISPLAY. TO THE PRICES
LISTED, YOU MUST ADD 174 € FOR THE DISPLAY.

42
MODEL BUCKET RAIN GAUGES AND DATALOGGER FOR RAIN GAUGES EURO

HD2013 Rain gauge with tipping bucket, area 400 cm2, for temperature range +4 °C… +70 °C. Standard resolution 0.2 mm. On 732
request when placing the order resolution 0.1 or 0.5mm. Output contact normally closed.

HD2013R Rain gauge with tipping bucket, area 400 cm2, equipped with heater for temperature range –20 °C…+70 °C. Standard 867
resolution 0.2 mm. On request when placing the order resolution 0.1 or 0.5mm. Output contact normally closed.
Power voltage 12 Vdc or 24 Vdc (to be specified when ordering) ± 10% / power absorption 165 W.

HD2013UA Optional contact output and analog output at choice between 4...20 mA or 0...10 Vdc (to be specified when ordering) for 195
HD2013 rain gauge. The contact output and the analog output are alternatives and the raing gauge is factory-configured
with analog output. Configurable measuring range (the analog output full scale, 20 mA or 10 V, can be associated to
different rainfall values). Power supply 7...30 Vdc. R L max = 50 • (Vcc – 7) Ω for 4...20 mA output. Measure remote reset
command.

HD2013UD Optional contact output and SDI-12 digital output for HD2013 rain gauge. The contact output and the SDI-12 output are 195
alternatives and the raing gauge is factory-configured with SDI-12 output. Power supply 7...30 Vdc. Measure remote
reset command.

HD2015 Rain gauge with tipping bucket, area 200 cm2, for temperature range +4 °C… +70 °C. Standard resolution 0.2 mm. On 552
request when placing the order resolution 0.1 or 0.5mm. Output contact normally closed.

HD2015R Rain gauge with tipping bucket, area 200 cm2, equipped with heater for temperature range –20 °C…+70 °C. Standard 688
resolution 0.2 mm. On request when placing the order resolution 0.1 or 0.5mm. Output contact normally closed.
Power voltage 12 Vdc or 24 Vdc (to be specified when ordering) ± 10% / power absorption 50 W.

Calibration report of rain gauges in 5 points. Net 195


HD2013.18 Bird spike. 125
HD2013.5K Accessory kit for the installation of the HD2013 rain gauge raised 500 mm from ground and the levelling (HD2013.5.1 + 182
HD2013.64.1 + HD2013.66).

HD2013.5K.1 Accessory kit for the installation of the HD2013 rain gauge raised 1 m from ground and the levelling (HD2013.5.3 + 218
HD2013.64.1 + HD2013.66).

HD2015.5K Accessory kit for the installation of the HD2015 rain gauge raised 500 mm from ground and the levelling (HD2013.5.1 + 182
HD2013.64 + HD2013.66).

HD2015.5K.1 Accessory kit for the installation of the HD2015 rain gauge raised 1 m from ground and the levelling (HD2013.5.3 + 218
HD2013.64 + HD2013.66).

HD2015.64K Kit of accessories for the installation of the rain gauge on the top of the mast and the levelling. Only for HD2015 and 160
HD2015R.

HD2003.75 Flange with tip for the ground to support the raised from the ground rain gauge. 84
HD2003.78 Flat base for fastening the raised from the ground rain gauge. 81
HD2013-DB Rain indicator Data Logger with LCD display; reads and stores up to 32,255 pulses coming 292
from a rain gauge with tipping bucket. Measurement compensation as a function of the rainfall
rate. It is equipped with insulated RS232C serial output. It includes HD32MTLogger software
downloadable from Delta OHM web site. 3.6V lithium battery power supply. IP67 protection
degree. Suitable for any kind of rain gauge. Supplied with 4-pole and 8 pole M12 female
connectors. The cables HD2110RS and CP25 for data download have to be ordered
separately.

HD32MTLogger CD-ROM with software HD32MTLogger for configuration, data download, monitor and PC data management. For 50
Windows® operating systems. For HD2013-DB data logger.

CP2013-DB 1m 4-pole cable to connect the rain gauge to the HD2013-DB fixed to the support staff. 4-pole M12 female connector on 36
one side, open wires on the other side. For HD2013-DB data logger.

HD2110 RS Serial connection cable with 8-pole M12 female connector on the instrument side and 9-pole SubD female connector for 15
RS232C on the PC side.

CP25 Serial connection cable with USB connector on the PC side and 8-pole M12 female connector on the instrument side. The 70
cable has a built-in USB/RS232 converter and connects the HD2013-DB data logger directly to the PC USB port.

BAT-2013DB 3.6 V lithium-thionyl chloride (Li-SOCl2) not rechargeable battery, capacity 8400 mAh, size C, Molex 5264 2-pole 36
connector.

FCM12.4 4-pole M12 female spare connector, for connecting the HD2013-DB data logger at distances greater than 1 m from the 8
rain gauge.

FCM12.8 8-pole M12 female spare connector, for connecting the HD2013-DB data logger to the PC. 9
HD2003.77/40 Clamping to fasten the data logger HD2013-DB to the support staff. 23

43
44
MODEL WEIGHING RAIN GAUGE EURO

HD2016 Weighing rain gauge, area 400 cm2. 3000 cc collecting reservoir. Automatic water discharge when the amount of water 2590
collected exceeds a configurable percentage of the reservoir capacity (by default 10%, corresponding to 300 cc).
Operating temperature from +4 °C to +60 °C. RS485 Modbus-RTU or SDI-12 output. Voltage-free output contact (NO).
Power supply: 10…15 Vdc. Adjustable feet for ground installation included in the kit.

HD2016R Weighing rain gauge, area 400 cm2. 3000 cc collecting reservoir. Automatic water discharge when the amount of water 2651
collected exceeds a configurable percentage of the reservoir capacity (by default 10%, corresponding to 300 cc).
Operating temperature from -20 °C to +60 °C. RS485 Modbus-RTU or SDI-12 output. Voltage-free output contact (NO).
Power supply: 10…15 Vdc for the measuring circuit, 12 Vdc / 90 W for the heater. Adjustable feet for ground installation
included in the kit.

CP18.5 12-conductor cable. 5 m long. 8-pin M12 connector on one side, free wires on the other side. 85
CP18.10 12-conductor cable. 10 m long. 8-pin M12 connector on one side, free wires on the other side. 152
HD2013.18 Bird spike. 125
HD2016.33K Accessory kit for the installation of the HD2016 rain gauge raised 500 mm from ground and the levelling. 182
HD2016.33K.1 Accessory kit for the installation of the HD2016 rain gauge raised 1 m from ground and the levelling. 218
HD2003.78 Flat base for fastening the raised from the ground rain gauge. 81

GROUND INSTALLATION INSTALLATION RAISED ABOVE GROUND

45
MODEL RAIN DETECTOR EURO

HD2013.2 Rain detector equipped with mounting bracket. 8-pole connector output according to IEC 60130-9 IP68. Power supply 182
12Vdc. Open collector output.

CP2013.2.5 5 m connection cable: 8-pole IEC 60130-9 IP68 female watertight connector on one end. Other lengths available on 86
request.

CP2013.2.10 10 m connection cable: 8-pole IEC 60130-9 IP68 female watertight connector on one end. Other lengths available on 125
request.

CON8 8-pole watertight connector according to IEC 60130-9 IP68. 18


HD2013.2D Bird spike, consisting of 6-spike ring (spike height: 60mm, ∅ 3mm), to be expressly requested when ordering 60

46
MODEL LEAF WETNESS SENSOR EURO

HD3901.5 Leaf wetness sensor with double sensitive surface. Two analog outputs 145
0.5…3 Vdc (one output for each of the two sensitive surfaces). Power supply
5…18 Vdc. Protection Degree IP 67. Complete with 4 poles 5 m cable with
open wires at the end.
HD3901.10 Leaf wetness sensor with double sensitive surface. Two analog outputs 172
0.5…3 Vdc (one output for each of the two sensitive surfaces). Power supply
5…18 Vdc. Protection Degree IP 67. Complete with 4 poles 10 m cable with
open wires at the end.

PROBES FOR THE MEASUREMENT OF THE


SOIL VOLUMETRIC WATER CONTENT (VWC)

2-ELECTRODE PROBES

HD3910.1.A.5 Two-electrode probe for the measurement of the soil volumetric water content. Standard 0.5…3 V (0.5 V = 0 %VWC, 117
3 V = 60 %VWC) voltage analog output. On request, 0…2.5 V, 0…5 V or 0…10 V output. Cable length 5 m.
HD3910.1.A.10 Two-electrode probe for the measurement of the soil volumetric water content. Standard 0.5…3 V (0.5 V = 0 %VWC, 152
3 V = 60 %VWC) voltage analog output. On request, 0…2.5 V, 0…5 V or 0…10 V output. Cable length 10 m.
HD3910.1.S.5 Two-electrode probe for the measurement of the soil volumetric water content. SDI-12 digital output. Cable length 5 m. 125
HD3910.1.S.10 Two-electrode probe for the measurement of the soil volumetric water content. SDI-12 digital output. Cable length 10 m. 165
HD3910.1.5 Two-electrode probe for the measurement of the soil volumetric water content. RS485 digital output with Modbus-RTU 131
protocol. Cable length 5 m.
HD3910.1.10 Two-electrode probe for the measurement of the soil volumetric water content. RS485 digital output with Modbus-RTU 165
protocol. Cable length 10 m.

3-ELECTRODE PROBES

HD3910.2.A.5 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. Standard 0.5…3 V 132
(0.5 V = 0 %VWC, 3 V = 60 %VWC) voltage analog output. On request, 0…2.5 V, 0…5 V or 0…10 V output. Cable
length 5 m.
HD3910.2.A.10 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. Standard 0.5…3 V 172
(0.5 V = 0 %VWC, 3 V = 60 %VWC) voltage analog output. On request, 0…2.5 V, 0…5 V or 0…10 V output. Cable
length 10 m.
HD3910.2.S.5 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. SDI-12 digital 145
output. Cable length 5 m.
HD3910.2.S.10 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. SDI-12 digital 177
output. Cable length 10 m.
HD3910.2.5 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. RS485 digital 145
output with Modbus-RTU protocol. Cable length 5 m.
HD3910.2.10 Three-electrode probe for the measurement of the soil volumetric water content in restricted volumes. RS485 digital 185
output with Modbus-RTU protocol. Cable length 10 m.

47
MODEL TEMPERATURE PROBES EURO

TP32MT.1P.I 4-wire 1/3 DIN Pt100 temperature probe, Ø 4 mm, 148


L=150 mm, pointed, 5 m cable, isolated sensor.
Temperature range -40…+100 °C.

TP32MT.1P.2 4-wire 1/3 DIN Pt100 temperature probe, Ø 4 mm, 162


L=230 mm, pointed, 5 m cable, isolated sensor.
Temperature range -50…+250 °C.

TP32MT.2.I 4-wire 1/3 DIN Pt100 temperature probe, Ø 6 mm, 145


L=150 mm, 5 m cable, isolated sensor.
Temperature range -40…+100 °C.

TP32MT.11P T type thermocouple temperature probe, Ø 4 mm, 101


L=150 mm, pointed, 5 m cable, isolated.
Temperature range -40…+100 °C.

TP32MT.12 T type thermocouple temperature probe, Ø 4 mm, 107


L=300 mm, 5 m cable, isolated. Temperature range
-40…+100 °C.

TP32MTT.03.A.2 4-wire Pt100 1/3 DIN temperature probe for measuring the soil temperature at a depth of 50 mm. With protective shield 130
from solar radiations. Temperature range -40…+85°C. 4-pole cable ended with open wires. Cable length 2 m.
TP32MTT.03.A.5 4-wire Pt100 1/3 DIN temperature probe for measuring the soil temperature at a depth of 50 mm. With protective shield 153
from solar radiations. Temperature range -40…+85°C. 4-pole cable ended with open wires. Cable length 5 m.
TP32MTT.03.A.10 4-wire Pt100 1/3 DIN temperature probe for measuring the soil temperature at a depth of 50 mm. With protective shield 180
from solar radiations. Temperature range -40…+85°C. 4-pole cable ended with open wires. Cable length 10 m.
TP32MTT.03.B.2 Temperature probe with two 4-wire Pt100 1/3 DIN sensors for measuring the soil and air temperature (± 50 mm). With 161
protective shield from solar radiations. Temperature range -40…+85°C. 8-pole cable ended with open wires. Cable
length 2 m.
TP32MTT.03.B.5 Temperature probe with two 4-wire Pt100 1/3 DIN sensors for measuring the soil and air temperature (± 50 mm). With 172
protective shield from solar radiations. Temperature range -40…+85°C. 8-pole cable ended with open wires. Cable
length 5 m.
TP32MTT.03.B.10 Temperature probe with two 4-wire Pt100 1/3 DIN sensors for measuring the soil and air temperature (± 50 mm). With 203
protective shield from solar radiations. Temperature range -40…+85°C. 8-pole cable ended with open wires. Cable
length 10 m.
TP32MTT.03.C.2 4-wire Pt100 1/3 DIN temperature probe for measuring the air temperature. With protective shield from solar radiations. 152
Temperature range -40…+85°C. 4-pole cable ended with open wires. Cable length 2 m.
TP32MTT.03.C.5 4-wire Pt100 1/3 DIN temperature probe for measuring the air temperature. With protective shield from solar radiations. 164
Temperature range -40…+85°C. 4-pole cable ended with open wires. Cable length 5 m.
TP32MTT.03.C.10 4-wire Pt100 1/3 DIN temperature probe for measuring the air temperature. With protective shield from solar radiations. 180
Temperature range -40…+85°C. 4-pole cable ended with open wires. Cable length 10 m.

48
MODEL TEMPERATURE PROBES EURO

HD9007.T29.1 White powder-coated aluminium mounting bracket. Supplied with screws for fixing to the LPS6.01 support. For the air 45
temperature probe TP32MTT.03.C or the protection from solar radiations HD9007.
HD9007.T29K White powder-coated aluminium mounting bracket. Supplied with accessories for fixing to a Ø 25…44 mm mast. For the 65
air temperature probe TP32MTT.03.C.

TP32MTT.03 Temperature probe with seven Pt100 1/3 DIN sensors for measuring the temperature at the depth of: +5 cm, 0, -5 cm, 650
-10 cm, -20 cm, -50 cm, -1 m with respect to the ground level, according to the WMO indications. Digital RS485 output
with Modbus-RTU protocol. 8-pole M12 male connector. 6…30 Vdc power supply. It can be connected to the RS485
port of the HD32MT.1 data logger. The CPM12-8D … must be ordered separately.

TP32MTT.03.1 Temperature probe with six Pt100 1/3 DIN sensors for measuring the temperature at the depth of: +5 cm, 0, -5 cm, -10 cm, - 600
20 cm, -50 cm with respect to the ground level, according to the WMO indications. Digital RS485 output with
Modbus-RTU protocol. 8-pole M12 male connector. 6…30 Vdc power supply. It can be connected to the RS485 port of
the HD32MT.1 data logger. The CPM12-8D … must be ordered separately.
TP32MTT.03B Accessory for signalling the presence of the probe. 20
CPM12-8D.5 8-pole cable. Length 5m. 8-pole M12 female connector on one end, open wires on the other side. 49
CPM12-8D.10 8-pole cable. Length 10m. 8-pole M12 female connector on one end, open wires on the other side. 84
Calibration report of TP32MTT.03 or TP32MTT.03.1 probe at 0 °C. Net 80

TP878.1SS.O Contact probe for solar panels. Pt100 4-wire. Cable 5 m. 79


Temperature working range -40…+85 °C.

49
MODEL PHOTOMETERS EURO

LPPHOT02 Outdoor photometric probe for measuring ILLUMINANCE (0…150 klux), CIE photopic filter, diffuser 616
for cosine correction. mVdc output for klux. Supplied with Calibration Report. On request
CPM12AA4… cables with 4-pole M12 connector (see page 60).

LPPHOT02AC Outdoor amplified photometric probe for outdoor use for measuring ILLUMINANCE (0…150 klux) CIE 759
photopic filter, diffuser for cosine correction. 4…20 mA output, integrated transmitter amplifier. Power
supply 10…30 Vdc. Supplied with Calibration Report. On request CPM12AA4… cables with 4-pole
M12 connector (see page 60).
LPPHOT02AV Outdoor amplified photometric probe for outdoor use for measuring ILLUMINANCE (0…150 klux) CIE 759
photopic filter, diffuser for cosine correction. Output: 0…1Vdc, 0…5Vdc or 0…10Vdc to be defined when
ordering, integrated transmitter amplifier. Power supply 10…30 Vdc (15…30 Vdc for output
0…10 Vdc). Supplied with Calibration Report. On request CPM12AA4… cables with 4-pole M12
connector (see page 60).

RADIOMETERS
LPUVA02 Radiometric probe for outdoor use for measuring IRRADIANCE in the UVA spectral range 671
(315...400 nm). μV per μW/cm2 output. Supplied with Calibration Report. On request CPM12AA4…
cables with 4-pole M12 connector (see page 60).
LPUVA02AC Amplified radiometric probe for outdoor use for measuring IRRADIANCE in the UVA spectral range 814
(315...400 nm). Output: 4…20mA (0…150 W/m2), integrated transmitter amplifier. Power supply
10…30 Vdc. Supplied with Calibration Report. On request CPM12AA4… cables with 4-pole M12
connector (see page 60).
LPUVA02AV Amplified radiometric probe for outdoor use for measuring IRRADIANCE in the UVA spectral range 814
(315...400 nm). Output: 0…1Vdc, 0…5Vdc or 0…10Vdc (0…150 W/m2) to be defined when ordering,
integrated transmitter amplifier. Power supply 10…30 Vdc (15…30 Vdc for output 0…10 Vdc). Supplied
with Calibration Report. On request CPM12AA4… cables with 4-pole M12 connector (see page 60).
LPUVB02 Amplified radiometric probe for outdoor use for measuring IRRADIANCE in the UVB spectral range 1166
(peak at 305 nm). Typical sensitivity 5V/(W/m2), measuring range 0…1 W/m2 , impedance 10 KΩ, power
supply 7…30 Vdc, typical absorption 3mA. Supplied with Calibration Report. On request
CPM12AA8… cables with 8-pole M12 connector (see page 60).
LPUVI02AC Amplified radiometric probe for outdoor use for measuring UV INDEX. Output: 4…20mA (0…16 UV 1485
index). Supplied with shade disk, cartridge with silica-gel crystals, spare sachets, levelling device, female
M12 connector and Calibration Report. Power supply 8…30 Vdc. On request CPM12AA4… cables
with 4-pole M12 connector (see page 60).
LPUVI02.1AC Amplified radiometric probe for outdoor use for measuring UV INDEX. Output: 4…20mA (0…20 UV 1485
index). Supplied with shade disk, cartridge with silica-gel crystals, spare sachets, levelling device, female
M12 connector and Calibration Report. Power supply 8…30 Vdc. On request CPM12AA4… cables
with 4-pole M12 connector (see page 60).
LPUVI02AV Amplified radiometric probe for outdoor use for measuring UV INDEX. Output: 0…1Vdc, 0…5Vdc or 1485
0…10Vdc (0…16 UV index) to be defined when ordering. Supplied with shade disk, cartridge with silica-
gel crystals, spare sachets, levelling device, female M12 connector and Calibration Report. Power supply
8…30 Vdc (15…30 Vdc for output 0…10 Vdc). On request CPM12AA4… cables with 4-pole M12
connector (see page 60).
LPUVI02.1AV Amplified radiometric probe for outdoor use for measuring UV INDEX. Output: 0…1Vdc, 0…5Vdc or 1485
0…10Vdc (0…20 UV index) to be defined when ordering. Supplied with shade disk, cartridge with silica-
gel crystals, spare sachets, levelling device, female M12 connector and Calibration Report. Power supply
8…30 Vdc (15…30 Vdc for output 0…10 Vdc). On request CPM12AA4… cables with 4-pole M12
connector (see page 60).
LPPAR04BL Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of 393
chlorophyll). Cosine correction. Measuring range 0...5000 µmol m-2s-1. Output 0...2.5 Vdc. Power supply
5.5...10 Vdc. Cable L=5m. Supplied with base with levelling device.

ACCESSORIES FOR PHOTOMETERS AND RADIOMETERS


LPS1 Only attachment bracket, suitable for mast with diameter 40 ÷ 50 mm. 70
Installation on horizontal or vertical mast.

LPSP1 Spare shade disk. 23


LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17
LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33
LPRING02 Base with levelling device and adjustable holder for mounting photometers and radiometers in an inclined 254
position (specify upon ordering on which photometer/radiometer model has to be mounted).

LPS6 Kit for the installation of photometers, radiometers and pyranometers. The kit includes: 750 mm mast (HD2003.83.1), 247
base fitting (LPS6.04), graduated support plate (LPS6.01), bracket for pyranometers (LPS6.03). On request,
HD9007T29.1 bracket for HD9007 or HD32MTT.03.C (see the drawing on page 70).

50
MODEL RS485 MODBUS-RTU TRANSMITTER FOR PHOTOMETERS EURO

LPPHOTS Transmitter with RS485 MODBUS-RTU output for photometric probes with output in mV. Connections via screw 193
terminals. Wall mount casing. Power supply 5…30 Vdc. Casing dimensions: 80 x 84 x 44 mm. IP 66 protection degree.
Operating temperature / humidity: -30...+70 °C / 0...90 %RH not condensing. For LPPHOT 01, LPPHOT 02 and
LPPHOT 03 probes.

51
LIGHT PROBES WITH ANALOG OR RS485 MODBUS-RTU OUTPUT
MODEL
AND M12 CONNECTOR FOR OUTDOOR
VERSIONS
LP…03 LP…03 LP…03 LP…03
Description LP…03
BL BLAC BLAV BLS
EURO EURO EURO EURO EURO
LPPHOT03 Photometric probe for measuring illuminance, for outdoor use, CIE photopic
filter, diffuser for cosine correction, dome in K5.
Output in mV per klux, normalized 4 ÷ 20 mA or 0 ÷ 10 Vdc or RS485
MODBUS-RTU depending on the model. Working temperature -20 ÷ +60 °C. 318 412 476 476 502
M12 male 4-pole (models with analog output) or 8-pole (model with RS485
MODBUS-RTU output) connector. On request CPM12AA4… (except
LPPHOT03BLS) or CPM12-8D (only LPPHOT03BLS) cable with M12
female connector (see page 60).
LPRAD03 Radiometric probe for measuring irradiance, for outdoor use, CIE photopic filter,
diffuser for cosine correction, dome in K5. Spectral range 400 ÷ 1050 nm.
Output in mVdc per W/cm2, normalized 4 ÷ 20 mA or 0 ÷ 10 Vdc or RS485
MODBUS-RTU depending on the model. Working temperature -20 ÷ +60 °C. 340 433 499 499 526
M12 M12 male 4-pole (models with analog output) or 8-pole (model with RS485
MODBUS-RTU output) connector. On request CPM12AA4… (except
LPPHOT03BLS) or CPM12-8D (only LPPHOT03BLS) cable with M12
female connector (see page 60).
LPPAR03 Radiometric probe for measuring photon flow in the field of photosynthesis of
chlorophyll PAR, for outdoor use, diffuser for cosine correction, dome in K5.
Spectral range 400 ÷ 700 nm.
Output in µV per µmol m-2s-1, normalized 4 ÷ 20 mA or 0 ÷ 10 Vdc or RS485
MODBUS-RTU depending on the model. Working temperature -20 ÷ +60 °C. 359 434 498 498 524
M12 M12 male 4-pole (models with analog output) or 8-pole (model with RS485
MODBUS-RTU output) connector. On request CPM12AA4… (except
LPPHOT03BLS) or CPM12-8D (only LPPHOT03BLS) cable with M12
female connector (see page 60).
LPUVA03 Radiometric probe for measuring irradiance in the UVA, for outdoor use,
diffuser for cosine correction, dome in K5.
Spectral range 315 ÷ 400 nm peak 365 nm.
Output in µV per µW/cm2, normalized 4 ÷ 20 mA or 0 ÷ 10 Vdc or RS485
MODBUS-RTU depending on the model. Working temperature -20 ÷ +60 °C. 384 477 542 542 569
M12 M12 male 4-pole (models with analog output) or 8-pole (model with RS485
MODBUS-RTU output) connector. On request CPM12AA4… (except
LPPHOT03BLS) or CPM12-8D (only LPPHOT03BLS) cable with M12
female connector (see page 60).
LPUVB03 Radiometric probe for measuring irradiance in the UVB, for outdoor use,
diffuser for cosine correction, dome in Quartz.
Spectral range 280 ÷ 315 nm peak 304 nm. --- --- --- 866 ---
0 ÷ 5 Vdc normalized output. Working temperature -20 ÷ +60 °C. M12
male 8-pole connector. On request CPM12AA8… cable with 8-pole M12
female connector (see page 60).

ORDERING CODE – CABLE CHOICE

mV per klux (PHOT)


LP 03 Blank = mV output µV per µW/cm2 (RAD, UVA)
BL = mV output + base with levelling device 2 1
µV per µmol m- s- (PAR)
BLAC = 4 ÷ 20 mA output + base with levelling device
BLAV = 0 ÷ 10 V output (0 ÷ 5 V for UVB) + base with levelling device
BLS = RS485 MODBUS-RTU output + base with levelling device

PHOT = Photometric probe : illuminance


RAD = Radiometric probe : irradiace VIS-NIR
PAR = Photosynthetically Active Radiation
UVA = Radiometric probe in the UVA range
UVB = Radiometric probe in the UVB range

CPM12 . Length: 2 = 2 m, 5 = 5 m, 10 = 10 m

AA4 = with 4-pole M12 connector


(for PHOT, RAD, PAR, UVA with analog output)
AA8 = with 8-pole M12 connector (for UVB)
- 8D = with 8-pole M12 connector
(for PHOT, RAD, PAR, UVA with RS485 output)

52
MODEL PYRANOMETERS EURO

SECONDARY STANDARD PYRANOMETERS


LPPYRA10 Pyranometer "secondary standard" according to ISO 9060 supplied with shade disk, cartridge with 1760
silica-gel crystals, 2 spare sachets, levelling device and Calibration Report. On request CPM12AA4…
cables with 4-pole M12 connector (see page 60).

LPPYRA10AC Pyranometer "secondary standard" according to ISO 9060 supplied with shade disk, cartridge with 1914
silica-gel crystals, 2 spare sachets, levelling device and Calibration Report. 4÷20mA current output,
integrated amplifier-transmitter. Power supply 10÷30Vdc. On request CPM12AA4… cables with 4-
pole M12 connector (see page 60).

LPPYRA10AV Pyranometer "secondary standard" according to ISO 9060 supplied with shade disk, cartridge with 1914
silica-gel crystals, 2 spare sachets, levelling device and Calibration Report. 0÷1V, 0÷5V or 0÷10V
voltage output to be defined when ordering, integrated amplifier-transmitter. Power supply 10÷30Vdc
for 0÷1V and 0÷5V output. Power supply 15÷30Vdc for 0÷10V output. On request CPM12AA4…
cables with 4-pole M12 connector (see page 60).

LPPYRA10S Pyranometer "secondary standard" according to ISO 9060 supplied with shade disk, cartridge with 1936
(RS485 silica-gel crystals, 2 spare sachets, levelling device and Calibration Report. RS485 serial output with
MODBUS) MODBUS-RTU protocol. Power supply 5÷30Vdc. On request cables CPM12-8D… with 8-pole
M12 female connector (see page 60).

LPPYRA10S12 Pyranometer "secondary standard" according to ISO 9060 supplied with shade disk, cartridge with 1936
(SDI-12) silica-gel crystals, 2 spare sachets, levelling device and Calibration Report. SDI-12 output. Power
supply 7÷30Vdc. On request cables CPM12-8D… with 8-pole M12 female connector (see page 60).

LPPYRA13 Pyranometer "secondary standard" according to ISO 9060 with shadow ring for measuring the diffuse 2464
radiation only. Supplied with shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling
device and Calibration Report. On request CPM12AA4… cables with 4-pole M12 connector (see
page 60).

LPPYRA13AC Pyranometer "secondary standard" according to ISO 9060 with shadow ring for measuring the diffuse 2607
radiation only. Supplied with shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling
device and Calibration Report. 4…20mA current output, integrated transmitter amplifier. Power
supply 10…30Vdc. On request CPM12AA4… cables with 4-pole M12 connector (see page 60).

LPPYRA13AV Pyranometer "secondary standard" according to ISO 9060 with shadow ring for measuring the diffuse 2607
radiation only. Supplied with shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling
device and Calibration Report. 0…1Vdc, 0..5Vdc or 0…10Vdc voltage output to be defined when
ordering, integrated transmitter amplifier. Power supply 10…30Vdc (15…30Vdc for output
0…10Vdc). On request CPM12AA4… cables with 4-pole M12 connector (see page 60).

LPPYRA13S Pyranometer "secondary standard" according to ISO 9060 with shadow ring for measuring the diffuse 2629
(RS485 radiation only. Supplied with shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling
MODBUS) device and Calibration Report. RS485 serial output with MODBUS-RTU protocol. Power supply
5…30Vdc. On request CPM12-8D… cables with 8-pole M12 connector (see page 60).

LPPYRA13S12 Pyranometer "secondary standard" according to ISO 9060 with shadow ring for measuring the diffuse 2629
(SDI-12) radiation only. Supplied with shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling
device and Calibration Report. SDI-12 output. Power supply 7…30Vdc. On request CPM12-8D…
cables with 8-pole M12 connector (see page 60).

LPS1 Only attachment bracket for LPPYRA 10… pyranometers, suitable for mast with diameter 40 ÷ 50 mm. 70
Installation on horizontal or vertical mast.

LPSP1 Spare shade disk. 23


LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17
LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33
LPRING02 Base with levelling device and adjustable holder for mounting the LPPYRA02 and LPPYRA10 series 254
pyranometers in an inclined position (specify upon ordering on which pyranometer model has to be
mounted).

LPRING12 Ring base for measuring the diffused radiation, for LPPYRA02 and LPPYRA10 pyranometers. 693

For the cables and the installation accessories, please see from pg. 60.
The warranty of the "secondary standard" pyranometers can be extended free of charge up to 6 years after registration on the Delta OHM website.

53
MODEL FIRST CLASS PYRANOMETERS EURO

LPPYRA02 First Class pyranometer according to ISO 9060. Supplied with: shade disk, cartridge with silica-gel 957
crystals, 2 spare sachets, levelling device, connector and Calibration Report. On request CPM12AA4…
cables with 4-pole M12 connector (see page 60).

LPPYRA02AC First Class pyranometer according to ISO 9060. Supplied with: shade disk, cartridge with silica-gel 1095
crystals, 2 spare sachets, levelling device, connector and Calibration Report. 4…20mA current output,
integrated transmitter amplifier. Power supply 10…30Vdc. On request CPM12AA4… cables with 4-
pole M12 connector (see page 60).
LPPYRA02AV First Class pyranometer according to ISO 9060. Supplied with: shade disk, cartridge with silica-gel 1095
crystals, 2 spare sachets, levelling device, connector and Calibration Report. 0…1Vdc, 0..5Vdc or
0…10Vdc voltage output to be defined when ordering, integrated transmitter amplifier. Power supply
10…30Vdc (15…30Vdc for output 0…10Vdc). On request CPM12AA4… cables with 4-pole M12
connector (see page 60).

LPPYRA02S First Class pyranometer according to ISO 9060. Supplied with: shade disk, cartridge with silica-gel 1117
crystals, 2 spare sachets, levelling device, connector and Calibration Report. RS485 serial output with
(RS485
MODBUS) MODBUS-RTU protocol. Power supply 5…30Vdc. On request CPM12-8D… cables with 8-pole
M12 connector (see page 60).

LPPYRA02S12 First Class pyranometer according to ISO 9060. Supplied with: shade disk, cartridge with silica-gel crystals, 1117
2 spare sachets, levelling device, connector and Calibration Report. SDI-12 output. Power supply
(SDI-12)
7…30Vdc. On request CPM12-8D… cables with 8-pole M12 connector (see page 60).

HD9906.51 Ventilation and heating unit. The unit can be used with LPPYRA02 and LPPYRA10 pyranometers, 680
LPPIRG01 pyrgeometer, LPPHOT02, LPUVA02 and LPUVB02 radiometers in fixed
installations. Working temperature from -30°C to +70°C. Power supply 12Vdc. Power requested
10 W.

HD9906.51F Spare filter for ventilation and heating unit HD9906.51. 25


LPS1 Only attachment bracket for pyranometers of the LPPYRA02 series, suitable for mast with diameter 40 ÷ 70
50 mm. Installation on horizontal or vertical mast.

LPPYRA12 First Class pyranometer according to ISO 9060 with shadow ring for measuring the diffuse radiation 1672
only. Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device and
Calibration Report. On request CPM12AA4… cables with 4-pole M12 connector (see page 60).

LPPYRA12AC First Class pyranometer according to ISO 9060 with shadow ring for measuring the diffuse radiation 1804
only. Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device and
Calibration Report. 4…20mA current output, integrated transmitter amplifier. Power supply
10…30Vdc. On request CPM12AA4… cables with 4-pole M12 connector (see page 60).

LPPYRA12AV First Class pyranometer according to ISO 9060 with shadow ring for measuring the diffuse radiation 1804
only. Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device and
Calibration Report. 0…1Vdc, 0..5Vdc or 0…10Vdc voltage output to be defined when ordering,
integrated transmitter amplifier. Power supply 10…30Vdc (15…30Vdc for output 0…10Vdc). On
request CPM12AA4… cables with 4-pole M12 connector (see page 60).
LPPYRA12S First Class pyranometer according to ISO 9060 with shadow ring for measuring the diffuse radiation 1826
(RS485 only. Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device and
MODBUS) Calibration Report. RS485 serial output with MODBUS-RTU protocol. Power supply 5…30Vdc.
On request CPM12-8D… cables with 8-pole M12 connector (see page 60).

LPPYRA12S12 First Class pyranometer according to ISO 9060 with shadow ring for measuring the diffuse radiation only. 1826
(SDI-12) Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device and Calibration
Report. SDI-12 output. Power supply 7…30Vdc. On request CPM12-8D… cables with 8-pole M12
connector (see page 60).

LPRING12 Ring base for measuring the diffused radiation, for LPPYRA02… and LPPYRA10… pyranometers. 693

LPRING02 Base with levelling device and adjustable holder for mounting the LPPYRA02 and LPPYRA10 series 254
pyranometers in an inclined position (specify upon ordering on which pyranometer model has to be
mounted).

LPRING04 Adjustable holder for mounting the LPPYRA02 and LPPYRA10 series pyranometers in an inclined 226
position on ∅ 40 mm mast with internal thread (specify upon ordering on which pyranometer model
has to be mounted).

LPSP1 Spare shade disk. 23


LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17
LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33
The warranty of the first class pyranometers can be extended free of charge up to 6 years after registration on the Delta OHM website.
54
MODEL SECOND CLASS PYRANOMETERS EURO

LPPYRA03 Second Class pyranometer according to ISO 9060. Supplied with levelling device and Calibration 363
Report. On request CPM12AA4… cables with 4-pole M12 connector (see page 60) and shade disk.

LPPYRA03AC Second Class pyranometer according to ISO 9060. Supplied with levelling device and Calibration 506
Report. 4…20mA current output, integrated transmitter amplifier. Power supply 10…30Vdc. On
request CPM12AA4… cables with 4-pole M12 connector (see page 60) and shade disk.

LPPYRA03AV Second Class pyranometer according to ISO 9060. Supplied with levelling device and Calibration 506
Report. 0…1Vdc, 0..5Vdc or 0…10Vdc voltage output to be defined when ordering, integrated
transmitter amplifier. Power supply 10…30Vdc (15…30Vdc for output 0…10Vdc). On request
CPM12AA4… cables with 4-pole M12 connector (see page 60) and shade disk.
LPPYRA03S Second Class pyranometer according to ISO 9060. Supplied with levelling device and Calibration 534
(RS485 Report. RS485 serial output with MODBUS-RTU protocol. Power supply 5…30Vdc. On request
MODBUS) CPM12-8D… cables with 8-pole M12 female connector (see page 60) and shade disk.

LPPYRA03S12 Second Class pyranometer according to ISO 9060. Supplied with levelling device and Calibration 534
(SDI-12) Report. SDI-12 output. Power supply 7…30Vdc. On request CPM12-8D… cables with 8-pole M12
female connector (see page 60) and shade disk.

LPRING04 Adjustable holder for mounting the LPPYRA03 series pyranometers in an inclined position on ∅ 40 mm 226
mast with internal thread (specify upon ordering on which pyranometer model has to be mounted).

LPRING13 Ring base for measuring the diffused radiation, for LPPYRA03 pyranometer. 709

LPSP2 Shade disk for pyranometer LPPYRA03. 23

LPS2 Base to fix with ∅ 16 x 500 mm mast to install the LPPYRA03 pyranometer. It easily allows to fix and 101
set, in combination with the HD2013.2.14 flange, the pyranometer LPPYRA 03.

LPS3 Only attachment bracket for LPPYRA03… pyranometers, suitable for mast with diameter 40 ÷ 50 mm. 72
Installation on horizontal or vertical mast.

LPS6 Kit for the installation of photometers, radiometers and pyranometers. The kit includes: 750 mm mast (HD2003.83.1), 247
base fitting (LPS6.04), graduated support plate (LPS6.01), bracket for pyranometers (LPS6.03). On request,
HD9007T29.1 bracket for HD9007 or HD32MTT.03.C (see the drawing on page 70).
CP24 PC connecting cable for the RS485 MODBUS parameters configuration of the LPPYRA…S pyranometers. With built-in 70
RS485/USB converter. 8-pole M12 connector on instrument side and A-type USB connector on PC side.

LPPYRA08 Second Class pyranometer according to ISO 9060, fast VERSIONS


response sensor. Supplied with Calibration Report.
Output according to the chosen configuration in µV LPPYRA08 LPPYRA08 LPPYRA08 LPPYRA08
per W/m2 or normalized 4 ÷ 20 mA or 0 ÷ 10 Vdc. BL BLAC BLAV
Male M12 connector. On request CPM12AA4… EURO EURO EURO EURO
cables with 4-pole M12 connector (see page 60).
506 594 677 677

LP PYRA 08

Blank = typical output 10 µV / (W/m2)


2
BL = typical output 10 µV / (W/m ), with base with bubble level
BLAC = output 4 ÷ 20 mA, with base with bubble level
BLAV = output 0 ÷ 10 Vdc with base with bubble level

2 = length 2 m
CPM12 AA4. 5 = length 5 m
10 = length 10 m

55
MODEL SILICON PHOTODIODE PYRANOMETERS EURO

LPSILICON- Pyranometer with silicon photodiode for measuring the GLOBAL SOLAR IRRADIANCE, diffuser 176
PYRA 04 for cosine correction. Spectral range 350…1100 nm. Typical sensitivity: 10 μV/W m-2. Measuring
range: 0…2000 W/m2. Fixed cable 5m long, terminated with open wires.

LPSILICON- Pyranometer with silicon photodiode for measuring the GLOBAL SOLAR IRRADIANCE, diffuser 242
PYRA 04BL for cosine correction. Spectral range 350…1100 nm. Typical sensitivity: 10 μV/W m-2. Measuring
range: 0…2000 W/m2. Fixed cable 5m long, terminated with open wires. Supplied with base with
levelling device.

MODEL PYRGEOMETER EURO

LPPIRG01 In accordance with ISO 9060. It measures the Far Infrared Radiation (FIR). Output in µV per W/m2. 1320
Supplied with shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device and
Calibration Report. On request CPM12AA8… cables with 8-pole M12 female connector (see page
60).
LPS1 Only attachment bracket for pyrgeometer LPPIRG01, suitable for mast with diameter 40 ÷ 50 mm. 70
Installation on horizontal or vertical mast.

LPRING02 Base with levelling device and adjustable holder for mounting the LPPIRG01 pyrgeometer in an 254
inclined position.

LPSP1 Spare shade disk. 23


LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17
LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33
LPS6 Kit for the installation of photometers, radiometers and pyranometers. The kit includes: 750 mm mast (HD2003.83.1), 247
base fitting (LPS6.04), graduated support plate (LPS6.01), bracket for pyranometers (LPS6.03). On request,
HD9007T29.1 bracket for HD9007 or HD32MTT.03.C (see the drawing on page 70).
HD2003.77/40 Clamping for mast ∅ 40 mm. 23
HD2003.83.1 Transverse mast L = 75 cm. 51
HD2003.85K Kit with adjustable height to mount pyranometers on ∅ 40 mm mast (HD2003.84, HD2003.85, HD2003.79). 134

MODEL PYRHELIOMETERS EURO

LPPYRHE16 First Class Pyrheliometer according to ISO 9060. Supplied with: light shade, 1837
cartridge with silica-gel crystals, 3 spare sachets, 4-pole M12 movable connector and
Calibration Report. On request CPM12AA4… cables with 4-pole M12 female
movable connector (see page 60).

LPPYRHE16AC First Class Pyrheliometer according to ISO 9060. Supplied with: light shade, cartridge with silica-gel crystals, 3 spare 1969
sachets, 4-pole M12 movable connector and Calibration Report. 4÷20mA current output signal, integrated amplifier-
transmitter. Power supply 10÷30Vdc. On request CPM12AA4… cables with 4-pole M12 female movable connector
(see page 60).
LPPYRHE16AV First Class Pyrheliometer according to ISO 9060. Supplied with: light shade, cartridge with silica-gel crystals, 3 spare 1969
sachets, 4-pole M12 movable connector and Calibration Report. 0÷1V, 0÷5V or 0÷10V voltage output signal to be
defined when ordering, integrated amplifier-transmitter. Power supply 10…30Vdc (15…30Vdc for output 0…10Vdc).
On request CPM12AA4… cables with 4-pole M12 female movable connector (see page 60).
LPPYRHE16S First Class Pyrheliometer according to ISO 9060. Supplied with: light shade, cartridge with silica-gel crystals, 3 spare 1969
( RS485 sachets, 8-pole M12 movable connector and Calibration Report. RS485 MODBUS-RTU serial output. Power supply
MODBUS) 5…30Vdc. On request cables CPM12-8D… with 8-pole M12 female connector (see page 60).

KIT 16.16 Kit composed of 5-position filters holder wheel with 3 Shott filters (OG530, RG630, 418
RG695), light shade and mounting accessories.

CP24 PC connecting cable for the RS485 MODBUS parameters configuration of the LPPYRHE16S pyrheliometer. With 70
built-in RS485/USB converter. 8-pole M12 connector on instrument side and A-type USB connector on PC side.

56
MODEL ALBEDOMETERS EURO

LPPYRA11 Albedometer composed of 2 "secondary standard" pyranometers according to ISO 9060. Supplied 2552
with: upper and bottom shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device,
support bracket ∅ 16x500mm and Calibration Report. On request CPM12AA8… cables with 8-pole
M12 female connector (see page 60).

LPPYRA05 Albedometer composed of 2 First Class pyranometers according to ISO 9060. Supplied with: upper and 1199
bottom shade disk, cartridge with silica-gel crystals, 2 spare sachets, levelling device, support bracket
∅ 16x500mm and Calibration Report. On request CPM12AA8… cables with 8-pole M12 female
connector (see page 60).

LPPYRA06 Albedometer composed of 2 Second Class pyranometers according to ISO 9060. Supplied with: upper 788
and bottom shade disk, support bracket ∅ 16x500mm and Calibration Report. On request
CPM12AA8… cables with 8-pole M12 female connector (see page 60).

LPSP1 Spare shade disk for LPPYRA05 and LPPYRA11 albedometers (upper pyranometer). 23
LPSP2 Spare shade disk for LPPYRA06 albedometer. 23
LPSP3 Spare shade disk for LPPYRA05 and LPPYRA11 albedometers (lower pyranometer). 29
LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17
LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33

MODEL NET IRRADIANCE METERS EURO

LPNET07 Net Irradiance Meter. Supplied with support bracket ∅ 16 x 500 mm, Calibration Report, 5 m cable. 463

LPNET14 4-sensor (2 pyranometers and 2 pyrgeometers) irradiance meter for measuring the net radiation between 0,3 µm and 2288
45 µm. Supplied with shaft φ=16 mm length 400 mm, birds spike, 2 dessicant sachets, levelling device and Calibration
Report. The four outputs of the single sensors are directed to two 8-pole M12 male connectors. On request two
CPM12AA8… cables with 8-pole M12 female connector.

57
MODEL SUNSHINE DURATION SENSORS EURO

LPSD18.1 Sensor for the measurement of the sunshine duration, referred to the 120 W/m2 threshold of direct radiation, 1155
according to the WMO indications. This sensor has no moving parts. RS485 MODBUS-RTU output and voltage-free
contact output (CLOSED = direct radiation above the threshold, OPEN = direct radiation below the threshold). Power
supply 7…30 Vdc. It can be fixed to a mast with a suitable optional accessory or installed on a horizontal plane by
using the optional mounting base. Built-in levelling device. This sensor does not require adjustement of the position
during the year. Equipped with anti-condensation system (1W @ 12 Vdc if connected). 8-pole M12 connector. On
request 5 or 10m standard CP18… cables with 8-pole M12 female connector.
LPSD18.2 Sensor for the measurement of the sunshine duration, referred to the 120 W/m2 threshold of direct radiation, 1155
according to the WMO indications. This sensor has no moving parts. RS485 MODBUS-RTU output, 0…1 Vdc
analog voltage output corresponding to 0…2000 W/m2 of direct radiation, digital voltage output (1V = direct
radiation above the threshold, 0V = direct radiation below the threshold). Power supply 7…30 Vdc. It can be fixed to a
mast with a suitable optional accessory or installed on a horizontal plane by using the optional mounting base. Built-in
levelling device. This sensor does not require adjustement of the position during the year. Equipped with anti-
condensation system (1W @ 12 Vdc if connected). 8-pole M12 connector. On request 5 or 10m standard CP18…
cables with 8-pole M12 female connector.
LPSD18.3 Sensor for the measurement of the sunshine duration, referred to the 120 W/m2 threshold of direct radiation, 1155
according to the WMO indications. This sensor has no moving parts. SDI-12 output and voltage-free contact output
(CLOSED = direct radiation above the threshold, OPEN = direct radiation below the threshold). Power supply 7…30 Vdc.
It can be fixed to a mast with a suitable optional accessory or installed on a horizontal plane by using the optional
mounting base. Built-in levelling device. This sensor does not require adjustement of the position during the year.
Equipped with anti-condensation system (1W @ 12 Vdc if connected). 8-pole M12 connector. On request 5 or 10m
standard CP18… cables with 8-pole M12 female connector.

HEATING:
LP SD18. . Blank = no heating
R = with heating

INSTALLATION:
B = basic version (45° fixed inclination)
O = version for installation on the horizontal base
V = version for installation on a vertical mast

OUTPUT:
1 = RS485 Modbus-RTU output and volt-free contact output.
2 = RS485 Modbus-RTU output, 0…1 Vdc voltage analog output and
0/1 V voltage digital output.
3 = SDI-12 output and volt-free contact output.

ACCESSORIES FOR SUNSHINE DURATION SENSORS


LPSD18.O Base for the installation of the LPSD18… sensor on an horizontal plane. Two 204
adjustable feet and one fixed. It allows the inclination of the sensor up to 80° with
respect to the vertical axis, to fit the position of the sun at the latitude of the installation
site.

LPSD18.V1 Support for the installation of the LPSD18… sensor on a Ø 40 mm mast. It allows the 182
inclination of the sensor up to 80° with respect to the vertical axis, to fit the position of
the sun at the latitude of the installation site.

LPSD18.19K Basic support for installation of the LPSD18… sensor on a flat base. The Sunshine Duration 86
Sensor has a fixed inclination of 45° with respect to the fixing plane.

LPSD18.22K Support for the installation of the LPSD18.O base on a Ø 40 mm mast (consists of LPSD18.13 + HD2013.66). 99
HD2003.83 Transverse mast L=150 cm 98
HD2003.83.1 Transverse mast L=75 cm 51
CP18.5 12-conductor cable. 5 m long. 8-pin M12 connector on one side, free wires on the other side. 85
CP18.10 12-conductor cable. 10 m long. 8-pin M12 connector on one side, free wires on the other side. 152
RS48 Cable for RS485 connection with built-in USB/RS485 converter. The cable has USB connector for PC and 3 separate 70
wires for the instruments. This cable is suitable for the models with RS485 output only.
R Heating option for the installation in cold climates, for the removal of ice and snow. Heating activated below +6°C. + 83
Heating power consumption: 3W @ 12 Vdc, 12W @ 24 Vdc.
LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17
LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33

58
59
ACCESSORIES FOR PYRANOMETERS ALBEDOMETERS AND
MODEL EURO
SENSORS FOR MEASURING SOLAR RADIATION
LPSP1 Shade disk for pyranometers LPPYRA02, LPPYRA05 (top pyranometer), LPPYRA10, LPPYRA11 (top 23
pyranometer ), LPPYRA12 and pyrgeometer LPPIRG01. Spare part.
LPSP2 Shade disk for pyranometer LPPYRA03, LPPYRA06. Spare part. 23
LPSP3 Bottom shade disk for pyranometer LPPYRA05. Spare part. 29
LPSP4 Flange for fixing the pyranometers on a flat surface. 79
LPSG Cartridge with desiccant silica-gel crystals, complete with O-ring and cap. Spare part. 17

LPG Pack of 5 sachets of silica-gel crystals. Spare part. 33


CPM12AA4.2 4-pole cable. L=2 m. 4-pole M12 connector on one end, open wires on the other end. 33
CPM12AA4.5 4-pole cable. L=5 m. 4-pole M12 connector on one end, open wires on the other end. 44
CPM12AA4.10 4-pole cable. L=10 m. 4-pole M12 connector on one end, open wires on the other end. 70
CPM12AA4.15 4-pole cable. L=15 m. 4-pole M12 connector on one end, open wires on the other end. 90
CPM12AA4.20 4-pole cable. L=20 m. 4-pole M12 connector on one end, open wires on the other end. 122
CPM12AA4.30 4-pole cable. L=30 m. 4-pole M12 connector on one end, open wires on the other end. 165
CPM12AA4.50 4-pole cable. L=50 m. 4-pole M12 connector on one end, open wires on the other end. 270
CPM12AA8.2 8-pole cable. L=2 m. 8-pole M12 connector on one end, open wires on the other end (not suitable for sensors with RS485 39
and SDI-12 output).
CPM12AA8.5 8-pole cable. L=5 m. 8-pole M12 connector on one end, open wires on the other end (not suitable for sensors with RS485 49
and SDI-12 output).
CPM12AA8.10 8-pole cable. L=10 m. 8-pole M12 connector on one end, open wires on the other end (not suitable for sensors with RS485 84
and SDI-12 output).
CPM12AA8.15 8-pole cable. L=15 m. 8-pole M12 connector on one end, open wires on the other end (not suitable for sensors with RS485 115
and SDI-12 output).
CPM12AA8.30 8-pole cable. L=30 m. 8-pole M12 connector on one end, open wires on the other end (not suitable for sensors with RS485 209
and SDI-12 output).
CPM12AA8.50 8-pole cable. L=50 m. 8-pole M12 connector on one end, open wires on the other end (not suitable for sensors with RS485 327
and SDI-12 output).
CPM12-8D.2 8-pole cable. L=2 m. 8-pole M12 connector on one end, open wires on the other end (only for sensors with RS485 and 39
SDI-12 output).
CPM12-8D.5 8-pole cable. L=5 m. 8-pole M12 connector on one end, open wires on the other end (only for sensors with RS485 and 49
SDI-12 output).
CPM12-8D.10 8-pole cable. L=10 m. 8-pole M12 connector on one end, open wires on the other end (only for sensors with RS485 and 84
SDI-12 output).
CONM12.4F 4-pole female M12 connector. 8
CONM12.4M 4-pole male M12 connector. 7
CONM12.8F 8-pole female M12 connector. 9
CONM12.8M 8-pole male M12 connector. 10
CPM12AA4.2D 4-pole cable. L=2 m. 4-pole M12 connectors on both ends. 50
CPM12AA4.5D 4-pole cable. L=5 m. 4-pole M12 connectors on both ends. 62
CPM12AA4.10D 4-pole cable. L=10 m. 4-pole M12 connectors on both ends. 87
CPM12AA4.20D 4-pole cable. L=20 m. 4-pole M12 connectors on both ends. 142
CPM12AA8.2D 8-pole cable. L=2 m. 8-pole M12 connectors on both ends (not suitable for sensors with RS485 and SDI-12 output) 57
CPM12AA8.5D 8-pole cable. L=5 m. 8-pole M12 connectors on both ends (not suitable for sensors with RS485 and SDI-12 output) 67
CPM12AA8.10D 8-pole cable. L=10 m. 8-pole M12 connectors on both ends (not suitable for sensors with RS485 and SDI-12 output) 92
CP24 PC connecting cable for the RS485 MODBUS parameters configuration of the LPPYRA…S pyranometers. With built-in 70
RS485/USB converter. 8-pole M12 connector on instrument side and A-type USB connector on PC side.

60
OPTOINSULATED SIGNAL CONVERTERS AMPLIFIERS
MODEL EURO
DIN RAIL OR WALL MOUNTING
HD978TR3 Configurable signal converter amplifier with 4÷20mA (20÷4mA) output. Input range -10 ..+60mVdc. Standard 152
configuration 0÷20mVdc. Minimum measuring range 2mVdc. For DIN rail 35mm. Configurable with HD778TCAL

HD978TR5 Configurable signal converter amplifier with 4÷20mA (20÷4mA) output. Input range -10 ..+60mVdc. Standard 164
configuration 0÷20mVdc. Minimum measuring range 2mVdc. Configurable with HD778TCAL. Container for Wall
Mount installation.

HD978TR4 Configurable signal converter amplifier with 0÷10Vdc (10÷0Vdc) output. Input range -10 ..+60mVdc. Standard 152
configuration 0÷20mVdc. Minimum measuring range 2mVdc. For DIN rail 35mm. Configurable with HD778TCAL

HD978TR6 Configurable signal converter amplifier with 0÷10Vdc (10÷0Vdc) output. Input range -10 ..+60mVdc. Standard 164
configuration 0÷20mVdc. Minimum measuring range 2mVdc. Configurable with HD778TCAL. Container for Wall
Mount installation.

HD778TCAL Voltage generator in the range -60mVdc…+60mVdc, controlled by PC through the RS232C serial port, DELTALOG7 216
software for setting K, J, T , N thermocouple transmitters and HD978TR3, HD978TR4 converters.

61
MODEL ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS EURO

HD2005.20 Tripod kit with adjustable legs for installing environmental sensors (anemometers, pyranometers, temperature and 290
humidity, etc.). Material: anodized aluminum. Max. height 2 m. It can be fixed on a flat base with screws or to the ground
with pegs. Foldable legs for the transport.
HD2005.20.1 Tripod kit with adjustable legs for installing environmental sensors (anemometers, pyranometers, temperature and 335
humidity, etc.). Material: anodized aluminum. Max. height 3 m. It can be fixed on a flat base with screws or to the ground
with pegs. Foldable legs for the transport.

62
EXAMPLE OF STATION

63
WEATHER STATION – INSTALLABLE COMPONENTS

STATION WITH TRIPOD AND MAINS POWER SUPPLY STATION WITH TRIPOD AND SOLAR PANEL POWER SUPPLY

STATION FIXED TO GROUND AND MAINS POWER SUPPLY STATION FIXED TO GROUND AND SOLAR PANEL POWER SUPPLY

64
MODEL ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS EURO

HD54.1K ∅ 60 mm anodized aluminum mast kit for installing environmental sensors (anemometers, pyranometers, temperature and 332
humidity, etc.). Includes: base (HD54.4), 2 masts ∅ 60 mm / L = 900 mm (HD54.6), coupling between the two masts (HD54.5),
adapter from ∅ 60 mm to ∅ 40 mm (HD54.7), vertical mast ∅ 40 mm / L = 500 mm (HD2013.5.1). It can be fixed on a flat
base with screws or to the ground with pegs.
Specify for which instrument it is requested.

65
MODEL ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS EURO

HD2003.77/40 Clamping for mast ∅ 40 mm 23

HD2003.77C 2 crossed sleeves for tube ∅ 40 mm 43

Kit to mount pyranometers on clamping ∅40 mm (HD2003.77/40, HD2003.79).


HD2003.79K
To install the LPPYRA02 and LPPYRA03 pyranometers on the transverse mast.
76

HD2004.20.40 Clamping for mast ∅ 40 mm 53

HD2004.20.40C 2 crossed clamps for tube ∅ 40 mm 104

Kit to mount pyranometers on clamping ∅40 mm (HD2003.20.40, HD2003.79).


HD2004.20.40K
To install the LPPYRA02 and LPPYRA03 pyranometers on the transverse mast.
74

HD2004.20.60 Clamping for mast ∅ 60 mm 58

HD2004.20.60C 2 crossed clamps for tube ∅ 60 mm 106

HD2013.2.14 Crossed clamping for mast ∅ 40 mm with 6 inputs ∅ 16 mm 76

HD2013.2.17 Support rod for sensors: ∅ 16 mm, L = 580 mm 37

HD2003.75 Flange for ∅ 40 mm mast, with grounding rod. 84

HD2003.78 Flange plate for ∅ 40 mm mast, to fasten on the floor. 81

66
MODEL ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS EURO

Kit with adjustable height to mount pyranometers on ∅ 40mm mast (HD2003.84,


HD2003.85K
HD2003.85, HD2003.79). Not suitable for LPPYRA03…
134

Mast kit ∅ 40 mm, height 2 m, in two pieces, one ∅ 33 mm tapered tip


HD2003.71
( HD2003.71.1 + HD2003.72 + HD2003.73)
143

HD2003.71K1 Mast kit ∅ 40 mm, height 3 m, in three pieces, one ∅ 33 mm tapered tip (HD2003.71.1 + HD2003.72.AA. + HD2003.72 160
+ 2 x HD2003.73).
HD2003K Mast kit ∅ 40 mm (not tapered), height 2 m, in two pieces (HD2003.72.1 + HD2003.72 + HD2003.73) 143
HD2003K1 Mast kit ∅ 40 mm (not tapered), height 3 m, in three pieces (HD2003.72.1 + HD2003.72.AA. + HD2003.72 + 2 x 160
HD2003.73).
HD2003.83 Transverse mast L=150 cm 98
HD2003.83.1 Transverse mast L=75 cm 51
HD54.9K U-shaped crossbar pole kit including: cross bar ∅ 40 mm and L=1500 mm, two extension bars ∅ 40 mm and accessories. For 195
HD54.3 and HD54.D.
HD54.9K1 As HD54.9K but with transverse mast L = 1 m 167

HD2003.74 Clamping with bubble level for ∅ 40 mm mast with 3 tie rods for bracing 52

Kit for bracing the 2 m mast, to fix on the ground with pegs (HD2003.80, HD2003.82,
HD2003.75K
stainless steel strings). 2 m fixing diameter.
220

HD2003.75K1 Kit for bracing the 3 m mast, to fix on the ground with pegs. on request

Kit for bracing the 2 m mast, to fasten on the floor with screws (HD2003.81,
HD2003.78K
HD2003.82, stainless steel strings). 2 m fixing diameter.
300

HD2003.78K1 Kit for bracing the 3 m mast, to fasten on the floor with screws. on request

Kit to mount photovoltaic panel 80 W 1200x530x34 mm on mast ∅ 40÷50 mm.


HD2004.22K
AISI 304 steel
160

HD2004.30 80 W monocrystalline photovoltaic panel. Dimensions 1200 x 530 x 34 mm. on request


HD2004.30K Kit to mount photovoltaic panel 30 W 675x350x35mm on mast ∅ 40÷50 mm. AISI 304 steel. 106
PFV.30W 30 W monocrystalline photovoltaic panel. Dimensions 675 x 350 x 35 mm. (Shipment only in Italy) on request
HD2004.25K Kit to mount photovoltaic panel 20 W 530x410x30mm on mast ∅ 40÷50 mm. AISI 304 steel 115

67
ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS

68
ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS

69
MODEL ACCESSORIES FOR INSTALLING ENVIRONMENTAL SENSORS EURO

LPS6 Kit for the installation of photometers, radiometers and pyranometers. The kit includes: 247
• 750 mm mast (HD2003.83.1);
• mast upper end (LPS6.04);
• graduated support plate (LPS6.01);
• bracket for pyranometers (LPS6.03).
On request, HD9007T29.1 bracket for HD9007 or HD32MTT.03.C.

70
71
MADE IN ITALY

GHM GROUP – Delta OHM


Delta OHM S.r.l. a socio unico Miglioriamo in continuazione i nostri prodotti, ci riserviamo il diritto di
Via Marconi 5 apportare modifiche senza preavviso.
We improve continually our products and reserve us the right to modify them
35030 Caselle di Selvazzano (PD) without prior notice.
ITALY Nous améliorons continuellement nos produits, nous réservons le droit de le
modifier sans préavis.
TEL.: 0039-0498977150 r.a. Wir entwickeln fortwährend unsere Produkte und behalten uns das Recht vor,
FAX: 0039-049635596 Sie abzuändern.
Mejoramos continuamente nuestros productos, nos reservamos el derecho de
e-mail: info@deltaohm.com modificarlos sin previso aviso.
Web Site: www.deltaohm.com Rev. 21/12/2018

Das könnte Ihnen auch gefallen