Sie sind auf Seite 1von 6

4-Port Antenna R1 B1

Frequency Range 790–960 1710–2180


Dual Polarization X X
HPBW 90° 90°
Adjust. Electr. DT 0°–10° 0°–6°
set by hand or by optional RCU (Remote Control Unit)

4-Port Antenna 790–960/1710–2180 90°/90° 15/18dBi 0°–10°/0°–6°T


Type No. 80010122V01
Lowband R1, connector 1– 2
790 – 960
Frequency range MHz 790 – 862 824 – 896 880 – 960
Polarization ° +45, –45 +45, –45 +45, –45
Average gain dBi 14.8 ... 14.8 ... 14.8 14.8 ... 15.0 ... 14.8 14.9 ... 15.1 ... 14.9
Tilt ° 0 ... 5 ... 10 0 ... 5 ... 10 0 ... 5 ... 10
Horizontal Pattern:
Half-power beam width ° 88 87 88
Front-to-back ratio
dB > 23 > 23 > 23
(180°±30°)
Cross polar ratio Typically: Typically: Typically:
Maindirection 0° > 18 > 18 > 20
dB
Sector ±60° > 10 > 10 > 13
±60° avg. 16 avg. 16 avg. 19
Vertical Pattern:
Half-power beam width ° 11.0 10.9 10.5
Electrical tilt ° 0 – 10, continuously adjustable
Min. sidelobe supression for °T 0 ... 5 ... 10 0 ... 5 ... 10 0 ... 5 ... 10
first sidelobe above main beam dB 18 ... 16 ... 14 16 ... 16 ... 15 16 ... 16 ... 15
Impedance Ω 50
VSWR < 1.5
Isolation: Intrasystem dB > 30
Isolation: Intersystem dB > 42 (790 – 960 // 1710 – 2180 MHz)
Intermodulation IM3 dBc < –150 (2 x 43 dBm carrier)
Max. power per input 500 (at 50 °C ambient temperature)
W
Total power 1000 (at 50 °C ambient temperature)
Subject to alteration.
936.4842/a

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com 80010122V01 Page 1 of 3

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
4-Port Antenna

Highband B1, connector 3– 4


1710 – 2180
Frequency range MHz 1710 – 1880 1850 – 1990 1920 – 2180
Polarization ° +45, –45 +45, –45 +45, –45
Average gain dBi 17.7 ... 17.8 ... 17.7 17.7 ... 18.0 ... 17.6 17.6 ... 17.8 ... 17.4
Tilt ° 0 ... 3 ... 6 0 ... 3 ... 6 0 ... 3 ... 6
Horizontal Pattern:
Half-power beam width ° 82 85 90
Front-to-back ratio
dB > 23 > 23 > 23
(180°±30°)
Cross polar ratio Typically: Typically: Typically:
Maindirection 0° > 17 > 16 > 15
dB
Sector ±60° > 10 > 12 > 10
±60° avg. 17 avg. 19 avg. 19
Vertical Pattern:
Half-power beam width ° 5.5 5.2 5.0
Electrical tilt ° 0 – 6, continuously adjustable
Min. sidelobe supression for °T 0 ... 3 ... 6 0 ... 3 ... 6 0 ... 3 ... 6
first sidelobe above main beam dB 18 ... 18 ... 16 18 ... 18 ... 16 18 ... 16 ... 16
Impedance Ω 50
VSWR < 1.5
Isolation: Intrasystem dB > 30
Isolation: Intersystem dB > 42 (790 – 960 // 1710 – 2180 MHz)
Intermodulation IM3 dBc < –150 (2 x 43 dBm carrier)
Max. power per input 250 (at 50 °C ambient temperature)
W
Total power 500 (at 50 °C ambient temperature)

Mechanical specifications

Input 4 x 7-16 female (long neck)


Connector position Bottom
Adjustment mechanism 2x, Position bottom
continuously adjustable
Wind load (at Rated N | lbf Frontal: 475 | 107
Wind Speed: 150 km/h) Maximal: 520 | 117
Max. wind velocity km/h 200
mph 124
Height / width / depth mm 1917 / 262 / 149
Subject to alteration.

inches 75.5 / 10.3 / 5.9


B1 Category of M (Medium)
mounting hardware
R1
Weight kg 27 / 29 (clamps incl.)
lb 59.5 / 63.9 (clamps incl.)
Packing size mm 2249 x 304 x 204
Correlation Table inches 88.5 x 12.0 x 8.0
Scope of Supply Panel and 2 units of clamps
936.4842/a

Frequency range Array Connector for 42 – 115 mm |


1.7– 4.5 inches diameter
790– 960 MHz R1 1–2
1710–2180 MHz B1 3–4

All specifications are subject to change without notice.


Page 2 of 3 80010122V01 The latest specifications are available at www.kathreinusa.com
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
Accessories
General Information

2)
Accessories (order separately if required)
3)

1)
Remarks Weight approx. Units per
Type No. Description
mm | inches kg | lb antenna

731651 1 clamp Mast diameter: 28 – 60 | 1.1 – 2.4 0.8 | 1.8 2


85010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 2
85010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2
737978 1 downtilt kit Downtilt angle: 0° – 11° 2.3 | 5.1 1

1917 | 75.5
1960 | 77.2
2000 | 78.7
2116 | 83.3
Accessories (included in the scope of supply)
738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 2
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
Material: Reflector screen: Weather-proof aluminum.
Fiberglass housing: It covers totally the internal antenna components.
The special design reduces the sealing areas to a minimum and
guarantees the best weather protection. Fiberglass material guarantees
optimum performance with regards to stability, stiffness, UV resistance
and painting. The color of the radome is light grey.
All screws and nuts: Stainless steel.
Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
Adjustment long neck
mechanism
with integrated
scale

4)
1) ’ 9 | 0.4
2) 72 | 2.8
3) 64 | 2.5
4) 35 – 42 | 1.4 –1.7

All dimensions in mm | inches

Layout of interface:

960 RCU
0– 17
79 1
0–
U
RC

218
0
149 | 5.9 *

167 | 6.6 *

–45° +45°
790–960 790–960
106 | 4.2
88 | 3.5
Subject to alteration.

45 | 1.8

–45° +45°
1710–2180 1710–2180

50 | 2.0
936.4842/a

103 | 4.1

180 | 7.1

262 | 10.3 *

Bottom view
* Dimensions refer to radome
All dimensions in mm | inches

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com 80010122V01 Page 3 of 3

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
Mounting Hardware
Clamp Included in the Scope of Supply

Suitable for mast diameter (mm) 42 – 115


[inches] [1.65 – 4.53]
Antenna – mast distance (mm) 20 – 25
[inches] [0.79 – 0.98]
Material of clamp and screws Hot-dip galvanized steel / stainless steel
Weight (kg) 1.1
[lb] [2.43]

152 [5.98]

100 [3.94]

[0.79–0.98]
40 [1.57]
72 [2.83]

20–25
40 [1.57]

15
2–1
’ 4 4.53]
5–
[1.6

M10 ‰MA = 25 Nm

M8 ‰MA = 20 Nm
35 [1.38]
64 [2.52]
125 [4.92]

20–25
[0.79–0.98]
Subject to alteration.
936.3920/c

Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm and [inches]
The additional nuts supplied are only meant as spares.

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com 738546 Page 1 of 1
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
General Instructions
for Adjustment Mechanism

Description of the adjustment mechanism (protective cap removed):

1
2

2
➀ Adjustment wheel with twist-lock ➀ Thread for fixing the protective To set the downtilt angle exactly,
function. cap or the RCU (Remote Control you must look horizontally at the
➁ Downtilt spindle with integrated Unit). scale. The lower edge of the gear-
scale. ➁ Gearwheel for RCU power drive. wheel must be used for alignment.

Manual adjustment procedure:

0° – max.°

max.° – 0°

Remove the protective cap. Set downtilt angle by rotating the Screw on the protective cap again.
adjustment wheel.

Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:


Subject to alteration.
936.4142

For a description of RCU installation please refer to the respective data sheet.
All specifications are subject to change without notice.
The latest specifications are available at www.kathreinusa.com Page 1 of 2

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
General Instructions for Feederline Installation
on XXPol Panels with four Connectors

Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.

Description of bottom end caps:

Ventilation hole

Layout of interface:
– RF inputs / polarization
– Adjustment mechanism
– Frequency range
Protective cap covering
adjustment mechanism

7-16 female (long neck)

Attachment of the feederline connector and RCU (optional):


In order to protect the adjustment mechanism the protective caps have to be attached during
feederline installation!

Subject to alteration.

Start with the rearside located interfaces. After feederline installation the optional For a full description of RCU installation
remote control units (RCU) can be please refer to the respective data sheet.
Place the connector carefully and fix the
mounted.
nut using a torque-wrench (according to
936.4142

the manufacturers guidelines).

All specifications are subject to change without notice.


Page 2 of 2 The latest specifications are available at www.kathreinusa.com
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com

Das könnte Ihnen auch gefallen