Sie sind auf Seite 1von 1

C14 C15

C12 C13
1
4' 4'-42"
FB/2
C15
6' 4'-9"
6' COLUMN
1
450 4'-42"

FB/2
10Ø@150c/c a
4'-0"

450
a
4'-9"

100
6' 10Ø@100c/c(a)
Section 1-1 PCC (1:4:8)
1 1
6'-0" II I I II
II
800 800
6' 8' 6' 3-20Ø(Thro)
C11 10Ø@150c/c 3-20Ø(Thro') C15
C9 C10
C8 6'

450
4' 3-20Ø(Thro) 2-20Ø(Ext)
4' Beam FB/1 (450x600) 3-20Ø(Thro')
4'
5' 5' Beam FB/2 (300X450)
10Ø@100c/c
C7 4'
SECTION X2-X2
5' 5'
4'
Schedule of Stirrups
C6 I: 10Ø-2L@100c/c
C1 C2 C3 C4 C5 II: 10Ø-2L@150c/c
III: 10Ø-2L@200c/c
COLUMN AND FOUNDATION PLAN
R E V I S ION
GENERAL NOTES: S.NO DATE DISCRIPTION
1) Dimensions are not to be measured from structural drawings. Written dimension as
per architectural Drgs.only shall be followed for all purposes.
2) Layout of building shall be provided as per Architectural grid plan.Similarly the
allignement of beams shall be fixed to coincide with the location of brick walls.
3) Footing shall be laid only on firm soil.
PROJECT:-
4) Safe bearing capicity of 1 5.0 T/m² has been adopted at a depth of 1.2M as per soil
investigation report. COMMUNITY CENTRE
5) Any discripency in the drg. shall be brought to the notice of the designer before CLIENT:-
execution of the work.
6) Developement length in compression and tension zones shall be 43 & 54 times the dia
of the bar respectively, in compliance with para. 25.2.1 of IS : 456 -2000.
ARCHITECT:-
7) M20 grade, mechanically mixed concrete, shall be used for all footings, beams &
slabs.
8) Building is designed for Ground +Two(2) stories with no provision for vertical
extension.
ADVANCE BUILDING TECHNOLOGIES
9)The laps in vertical steel shall be staggered in a manner such that not more the 50% 3A/167 G2 NARAYAN VILLA
AZAD NAGAR, KANPUR
laps are kept at any section.
Mob: 9532666888, 9305835617: e-mail: anoopgupta52@rediffmail.com
10)All dimensions are in M.K.S. system unless noted otherwise.
11) The Building is designed for Seismic Zone -III. DRAWING TITLE :-
12) Reinforcement shall be thermo mechancally treated (TMT) conforming to relevent IS DETAIL OF FOUNDATION
code. Alternatavely high strength deformed bars of grade Fe : 500 Conforming to IS
786-1985 may be used. DRAWING NO:-
ABT / Sirsaganj / S-1A
13) This drawing shall be read along with structural drawings for foundation, columns
and respective floors . DATE :- DESIGN BY:- CHKD BY:
For Foundation Detail Refer Drg No: 18-01-2018 ANOOP GUPTA
14) Grade of steel shall be Fe 500 everywhere.
ABT / Sirsaganj / S-1 A SHEET NO:- DRAWN BY:
REVISION
15) Grade of concrete in structure shall be M20. SUMIT
SCALE : NTS