Sie sind auf Seite 1von 4

Datasheet 2.4.

1 6/8/08 13:27 Page 1

IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.4.1

TRANSFORMER RECTIFIERS

REVISION 1

APPLICATION
Onshore, Offshore and Marine applications.

A wide and varied range of high quality transformer rectifiers are designed and manufactured at our Grantham works to
meet the market requirement for all land and marine structures necessitating an Impressed Current Cathodic Protection
system or a Marine Growth Anti Fouling system.

TRANSFORMER RECTIFIER UNIT DATA

The products have been developed to satisfy the most arduous environmental
conditions, giving safe operational reliability with minimal maintenance at
competitive price levels.

Two main types of transformer rectifiers are available ie: Air Cooled and Oil
Cooled, the selection of which may be specification derived or personal
choice. The final selection invariably being the environmental conditions and
relative to output rating, these will determine the physical size and cost of the
unit. Our engineers are able to assist you with this selection.

Input Power Supply 1 Phase and 3 Phase supplies to 660Volts, 50/60Hz are readily catered for
within our standard arrangements

Output Rating @ Voltages: 6 to 120Volts DC (British Standards state 50Volts DC output max)
Ambient Temperatures - Currents: 5 to 800Amps (Multiples of transformer rectifiers should be
10 to 55˚C considered for greater than 12kWatt)

Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605 DATASHEET
Email: cpc@cathodic.co.uk Website: www.cathodic.co.uk 2.4.1
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098
Datasheet 2.4.1 6/8/08 13:27 Page 2

IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.4.1

TRANSFORMER RECTIFIERS

REVISION 1

OUTPUT CONTROL

Manual

Switched Switch Control via control panel facia switches to select transformer
tappings, 15 and 63 step control available as standard

Auto Transformer Auto transformer (Variac) control indefinitely from 0 to 100%.

Electronic Electronic thyristor control from panel facia mounted potentiometer giving
indefinite variable adjustment from 3Volts to maximum rating.

Auto (Electronic) All auto systems operate from 3Volts to maximum rating and are fitted with a
manual override facility.

Constant Current Constant current maintains the output current at the preset value
irrespective of supply and output circuit changes.

Constant Potential A permanent reference electrode(s) controls the output current to maintain a
constant potential at the surface of the protected structure subject to
compensate for changes in electrolyte resistivity, coating efficiency, power
supply voltage variation, tidal conditions etc.

Enclosures A wide range of standard and purpose built arrangements up to IP66


protection levels.

Material Mild steel, Stainless Steel, Aluminium and Glass Reinforced Polyester are
available.

Finishes Epoxy/Polyurethane paint finishes on prepared shot blast, cleaned and zinc
chromate primed/Zinga base as standard. Options include Zinc flame
sprayed, natural bead blast finishes, etc.

Electrical/Electronic Selected to meet the specification requirement with particular emphasis on


Components high efficiency transformers and generously rated semi-conductors

DATASHEET Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605
2.4.1 Email: cpc@cathodic.co.uk Website: www.cathodic.co.uk
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098
Datasheet 2.4.1 6/8/08 13:27 Page 3

IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.4.1

TRANSFORMER RECTIFIERS

REVISION 1

FACILITY AVAILABLE Supply/Output Monitoring


Limit and Alarm (high and low)
Local/Remote indication facilities
4-20mA re-transmission signals
RCCD/MCB and fuse protection
Surge suppression
Lightning Arrestors
Metering
“Instant Off” timers
Synchronous timing

TESTS All transformer rectifiers undergo works testing to include the following as a
minimum:

• Wiring connection integrity

• Circuit continuity and compliance

• Operation at full output current and voltage far a minimum of 12 hours

• High voltage insulation resistance test

In addition new designs are subjected to a 12-24 hour heat run test at full
load to ensure that the temperature rises are within permitted limits for the
materials used in construction.

Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605 DATASHEET
Email: cpc@cathodic.co.uk Website: www.cathodic.co.uk 2.4.1
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098
Datasheet 2.4.1 6/8/08 13:27 Page 4

IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.4.1

TRANSFORMER RECTIFIERS

REVISION 1

TYPICAL TRANSFORMER RECTIFIER GENERAL ARRANGEMENT


(Model Shown Oil Cooled 75V / 125A)

TYPICAL TRANSFORMER RECTIFIER / POSITIVE JUNCTION BOX SITE ARRANGEMENT

DATASHEET Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605
2.4.1 Email: cpc@cathodic.co.uk Website: www.cathodic.co.uk
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098

Das könnte Ihnen auch gefallen