Sie sind auf Seite 1von 2

has different faces

and is difficult to find!


With SRAclinic® easy,
fast & reliable detectable.

atrial fibrillation - The complex way to diagnose


Search for atrial fibrillation
Optimized
Present
Unsatisfactory Increase of detection rate Search with
Search SRAclinic®


and detecting happens by longer derivation time
by chance
Automatic analysis and detection of
Mostly patient monitoring atrial fibrillation episodes
without ECG evaluation
Usability is easy, practical,
Rarely 24h Holter monitoring staff efficiently and reliable

Evaluation with a time lag Detects patients with a risk of


(>3 weeks) atrial fibrillation or acute atrial
fibrillation

SRA® - Optimal support for diagnosing atrial fibrillation

Stroke-Risk-Analysis (SRA®) from apoplex medical technologies


provides a scientifically proven solution in the search for atrial fibrillation.
SRAdoc® SRA24® SRAclinic®
100
90 90
80 80
70 >99 >99 70
SRA®

60 60 40
0%

50 50 %
17

40 40
30 30
20 20
10 10
0 0

sensitivity specificity 24h Holter ECG ECG


monitoring monitoring
Automatic detection rate of
With a sensitivity from 60% and 99% with SRA® (CEM)
atrial fibrillation patients with SRA® specificity patients with paroxysmal (aCEM)
atrial fibrillation outside of episodes Detection rate for paroxysmal
SRA® find atrial fibrillation patients are detected with SRA®. atrial fibrillation in percent
with an sensitivity and specificity from With a sensitivity and specificity from
>0,99 compared to a cardiac evalua- >0,99 patients with acute atrial fibril- The detection rate from new diagno-
tion. lation were detected. sed paroxysmal atrial fibrillation was
(Duning et al.; Extended electrocardiographic Poin- (Schaefer et al.; Improved Detection of Paroxysmal increased by 40% -
Atrial Fibrillation Utilizing a Software-Assisted Elect-
caré analyses for better idetfication of patients with
rocardiogram Approach (PLOS ONE 2014)) 170% with SRA®
paroxysmal atrial fibrillation; JClinExpCardiology
(2011)) (Rizos et al. Stroke (2012))
%$#
G section
5 minute EC



"! !

Procedure of a SRA® examination

1a 2 3 4

Monitoring

ANALYSIS ANALYSIS
SERVER REPORT

 %#% #



 %#%#
 
%% 
##
 
 %#%

   
 %%
  
 
!
!!

5 minute ECG section -


1b Eases the verification and
documentation of atrial fibrillation

Memory
Card

1a ECG derivation directly from the patient monitor


1b Traditional ECG derivation via separate electrodes / holter
2 Safe and anonymous ECG transfer via internet
3 Automatic analysis on the server of apoplex medical technologies. The original ECG will remain stored
on the SRA® Server and can accessed through the SRAclinic® Viewer
4 Prompt delivery of the analysis report via e-mail or internet access within a short and appropriate time

SRAclinic® provides medical and economic benefits

Fast and safe results


➔ SRAclinic delievers directly reliable results as a basis for an anticoagulation
®

Automatic analyse
➔ SRAclinic relives doctors evaluating ECG data and creates space for different medical activities
®

Profitable method
➔ SRAclinic shortens the hospital stays, contributes to quality assurance in the stroke unit
®

and generates more profit for the user.

SRAclinic® Onepager Version 1.0 | Subject to change in design and scope of delivery and as a result of ongoing technical development. Printed in Germany.

apoplex medical technologies GmbH


Delaware Avenue 1-3 • 66953 Pirmasens • Deutschland
Phone: +49(0)6331/698998-0 • Fax: +49(0)6331/698998-19
Mail: info@apoplexmedical.com • Internet: www.apoplexmedical.com

Das könnte Ihnen auch gefallen