Sie sind auf Seite 1von 30

Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 3A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 24W
KVA 3 Total loss 180W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 94.0%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 55 / 25
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV 11"
SIDE VIEW
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4

11"

FEATURES:
- Anti-vibration pads installed between the core/coil and FRONT VIEW
the enclosure
- Ground lug provided
81 4" 11"
- Leads brought-up and solidly positioned into separate
terminal boards 1"
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure 912"
- CSA certified / UL listed 1112"

MOUNTING: WALL

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 3B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 24W
KVA 3 Total loss 180W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 94.0%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 55 / 25
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV 11"
SIDE VIEW
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4

11"

FEATURES:
- Anti-vibration pads installed between the core/coil and FRONT VIEW
the enclosure
- Ground lug provided
81 4" 11"
- Leads brought-up and solidly positioned into separate
terminal boards 1"
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure 912"
- CSA certified / UL listed 1112"

MOUNTING: WALL

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 6A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 35W
KVA 6 Total loss 335W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.5
Efficiency = 94.1%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 85 / 39
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
51 4"
13116"

51 4"

191 4" 21" 183 16" 18" 21"


FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 101 2"

- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Copper windings
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 6B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 35W
KVA 6 Total loss 335W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.5
Efficiency = 94.1%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 85 / 39
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
51 4"
13116"

51 4"

191 4" 21" 183 16" 18" 21"


FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 1012"

- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Copper windings
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 10A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 42W
KVA 10 Total loss 520W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.6
Efficiency = 94.8%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 110 / 50
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV

9
16 "
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
1
5 4"
13116"

51 4"

191 4" 21" 183 16" 18" 21"


FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 1012"
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure FRONT VIEW SIDE VIEW
- CSA certified / UL listed

MOUNTING: WALL

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 10B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 42W
KVA 10 Total loss 520W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.6
Efficiency = 94.8%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 110 / 50
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV

9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
1
5 4"
13116"

51 4"

191 4" 21" 183 16" 18" 21"


FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 101 2"
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure FRONT VIEW SIDE VIEW
- CSA certified / UL listed

MOUNTING: WALL

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 15A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 55W
KVA 15 Total loss 861W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.3
Efficiency = 97.48%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 170 / 78
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0 133 16"
51 4"
13116"

51 4"

191 4" 21" 183 16" 18" 21"


FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
1012"
terminal boards
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL: MT 15B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 55W
KVA 15 Total loss 861W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.3
Efficiency = 97.48%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 170 / 78
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV
9
16 "
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0 133 16"
51 4"
13116"

51 4"

191 4" 21" 183 16" 18" 21"


FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
1012"
terminal boards
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 30A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 106W
KVA 30 Total loss 1664W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 97.56%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 250 / 140
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #14-#4


Secondary connectors per phase: #8-2/0
21" 141 4"

2212" 2212"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 3
118" 4"
- Ground lug provided
183 4" 123 4"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"(typ)
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 30B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 106W
KVA 30 Total loss 1664W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 97.56%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 250 / 140
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #14-#4


Secondary connectors per phase: #8-2/0
21" 141 4"

2212" 2212"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 3
118" 4"
- Ground lug provided
183 4" 123 4"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"(typ)
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 45A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 45 Total loss 2000W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 370 / 169
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #14-#4 2512" 163 8"


Secondary connectors per phase: #6-250MCM

27"

FEATURES:
- Anti-vibration pads installed between the core/coil and 1
2"
11 4"
the enclosure
23" 153 8"
- Ground lug provided
3
- Leads brought-up and solidly positioned into separate 4"
terminal boards
- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 45B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 45 Total loss 2000W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 370 / 169
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #14-#4 2512" 163 8"


Secondary connectors per phase: #6-250MCM

27"

FEATURES:
- Anti-vibration pads installed between the core/coil and 1
2"
11 4"
the enclosure
23" 153 8"
- Ground lug provided
3
- Leads brought-up and solidly positioned into separate 4"
terminal boards
- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 50A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 50 Total loss 2080W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 425 / 193
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #14-#4


Secondary connectors per phase: #6-250MCM
2512" 163 8"

27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"

- CSA enclosure: ventilated painted ASA 61gray


- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 50B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 50 Total loss 2080W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 425 / 193
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #14-#4


Secondary connectors per phase: #6-250MCM
2512" 163 8"

27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"

- CSA enclosure: ventilated painted ASA 61gray


- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 75A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 200W
KVA 75 Total loss 2800W
Primary (Volts) 600 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.7
Efficiency = 98.27%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 520 / 237
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #6-2/0


Secondary connectors per phase: #6-250MCM
2512" 163 8"

27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 75B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 200W
KVA 75 Total loss 2800W
Primary (Volts) 480 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.7
Efficiency = 98.27%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 520 / 237
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #6-2/0


Secondary connectors per phase: #6-250MCM
2512" 163 8"

27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 112.5A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 350W
KVA 112.5 Total loss 3438W
Primary (Volts) 600 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 3.8
Efficiency = 98.35%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 820 / 375
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #8-250MCM


303 8" 20"
Secondary connectors per phase: #2/0-600MCM

361 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
- Ground lug provided 13 8" 13 8" 2"
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 112.5B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 350W
KVA 112.5 Total loss 3438W
Primary (Volts) 480 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 3.8
Efficiency = 98.35%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 820 / 375
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #8-250MCM


303 8" 20"
Secondary connectors per phase: #2/0-600MCM

361 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
- Ground lug provided 13 8" 13 8" 2"
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 150A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 422W
KVA 150 Total loss 4042W
Primary (Volts) 600 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.53%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 995 / 451
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #4-250MCM 303 8" 20"


Secondary connectors per phase: #2/0-350MCM(D)

361 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
13 8" 13 8" 2"
- Ground lug provided
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 150B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 422W
KVA 150 Total loss 4042W
Primary (Volts) 480 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.53%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 995 / 451
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : #4-250MCM 303 8" 20"


Secondary connectors per phase: #2/0-350MCM(D)

361 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
13 8" 13 8" 2"
- Ground lug provided
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 225A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 610W
KVA 225 Total loss 6058W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.55%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1450 / 658
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : 2/0-350MCM 35" 2412"


Secondary connectors per phase: 4/0-600MCM(D)

463 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 112" 112"
- Ground lug provided 7
7
8" 8"
- Leads brought-up and solidly positioned into separate
terminal boards 33" 211 4"
- CSA enclosure: ventilated painted ASA 61gray 3
4"
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 225B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 610W
KVA 225 Total loss 6058W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.55%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1450 / 658
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : 2/0-350MCM 35" 2412"


Secondary connectors per phase: 4/0-600MCM(D)

463 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 112" 112"
- Ground lug provided 7
7
8" 8"
- Leads brought-up and solidly positioned into separate
terminal boards 33" 211 4"
- CSA enclosure: ventilated painted ASA 61gray 3
4"
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 300A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 790W
KVA 300 Total loss 7790W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.6%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1810 / 821
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
35" 2412"
Primary connectors per phase : 4/0-350MCM(S)
Secondary connectors per phase: 4/0-750MCM(D)

463 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
112" 112"
7 7
- Ground lug provided 8" 8"

- Leads brought-up and solidly positioned into separate 33" 211 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"

- Transformer meets the efficiency values as per CSA


FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 300B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 790W
KVA 300 Total loss 7790W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.6%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1810 / 821
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
35" 2412"
Primary connectors per phase : 4/0-350MCM(S)
Secondary connectors per phase: 4/0-750MCM(D)

463 4"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
112" 112"
7 7
- Ground lug provided 8" 8"

- Leads brought-up and solidly positioned into separate 33" 211 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"

- Transformer meets the efficiency values as per CSA


FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 450A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1100W
KVA 450 Total loss 10,100W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.3
Efficiency = 98.68%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2550 / 1157
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : N/A


Secondary connectors per phase: N/A 3612" 303 4"

515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 341 4" 301 4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 450B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1100W
KVA 450 Total loss 10,100W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.3
Efficiency = 98.68%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2550 / 1157
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : N/A


Secondary connectors per phase: N/A 3612" 303 4"

515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 341 4" 301 4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 500A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1200W
KVA 500 Total loss 10,220W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.69%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2760 / 1252
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : N/A 3612" 303 4"


Secondary connectors per phase: N/A

515 8"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
1" 1" 1" 1"
- Leads brought-up and solidly positioned into separate 341 4" 301 4"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW

- Copper ground strap between core/coil and enclosure


- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 500B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1200W
KVA 500 Total loss 10,220W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.69%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2760 / 1252
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : N/A 3612" 303 4"


Secondary connectors per phase: N/A

515 8"

FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
1" 1" 1" 1"
- Leads brought-up and solidly positioned into separate 341 4" 301 4"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW

- Copper ground strap between core/coil and enclosure


- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 600A1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1280W
KVA 600 Total loss 10,300W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.8%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 3150 / 1429
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : N/A


3612" 303 4"
Secondary connectors per phase: N/A

515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate 1" 1" 1" 1"
341 4" 301 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"

- Transformer meets the efficiency values as per CSA SIDE VIEW


FRONT VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD

MARCUS Phone: 1-800-267-7376


Fax: 1-866-205-7526
Email: Info@marcustransformer.com

TECHNICAL DATA MODEL:MT 600B1


3-PHASE ISOLATING

DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1280W
KVA 600 Total loss 10,300W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.8%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 3150 / 1429
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV

Primary connectors per phase : N/A


3612" 303 4"
Secondary connectors per phase: N/A

515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate 1" 1" 1" 1"
341 4" 301 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"

- Transformer meets the efficiency values as per CSA SIDE VIEW


FRONT VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings

Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date