DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 24W
KVA 3 Total loss 180W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 94.0%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 55 / 25
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV 11"
SIDE VIEW
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
11"
FEATURES:
- Anti-vibration pads installed between the core/coil and FRONT VIEW
the enclosure
- Ground lug provided
81 4" 11"
- Leads brought-up and solidly positioned into separate
terminal boards 1"
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure 912"
- CSA certified / UL listed 1112"
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 24W
KVA 3 Total loss 180W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 94.0%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 55 / 25
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV 11"
SIDE VIEW
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
11"
FEATURES:
- Anti-vibration pads installed between the core/coil and FRONT VIEW
the enclosure
- Ground lug provided
81 4" 11"
- Leads brought-up and solidly positioned into separate
terminal boards 1"
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure 912"
- CSA certified / UL listed 1112"
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 35W
KVA 6 Total loss 335W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.5
Efficiency = 94.1%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 85 / 39
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
51 4"
13116"
51 4"
- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Copper windings
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 35W
KVA 6 Total loss 335W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.5
Efficiency = 94.1%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 85 / 39
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
51 4"
13116"
51 4"
- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Copper windings
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 42W
KVA 10 Total loss 520W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.6
Efficiency = 94.8%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 110 / 50
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV
9
16 "
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
1
5 4"
13116"
51 4"
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 42W
KVA 10 Total loss 520W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.6
Efficiency = 94.8%
Insulation Class
Temperature Rise
Frequency 60Hz
Weight (LBS/KG) 110 / 50
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4 133 16"
1
5 4"
13116"
51 4"
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 55W
KVA 15 Total loss 861W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.3
Efficiency = 97.48%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 170 / 78
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV
9
16"
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0 133 16"
51 4"
13116"
51 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 55W
KVA 15 Total loss 861W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.3
Efficiency = 97.48%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 170 / 78
Connection Dyn1(TT-1) PHYSICAL DIMENSIONS
BIL. 10KV
9
16 "
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0 133 16"
51 4"
13116"
51 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 106W
KVA 30 Total loss 1664W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 97.56%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 250 / 140
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
2212" 2212"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 3
118" 4"
- Ground lug provided
183 4" 123 4"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"(typ)
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 106W
KVA 30 Total loss 1664W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 5.1
Efficiency = 97.56%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 250 / 140
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
2212" 2212"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 3
118" 4"
- Ground lug provided
183 4" 123 4"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"(typ)
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 45 Total loss 2000W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 370 / 169
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
27"
FEATURES:
- Anti-vibration pads installed between the core/coil and 1
2"
11 4"
the enclosure
23" 153 8"
- Ground lug provided
3
- Leads brought-up and solidly positioned into separate 4"
terminal boards
- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 45 Total loss 2000W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 370 / 169
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
27"
FEATURES:
- Anti-vibration pads installed between the core/coil and 1
2"
11 4"
the enclosure
23" 153 8"
- Ground lug provided
3
- Leads brought-up and solidly positioned into separate 4"
terminal boards
- CSA enclosure: ventilated painted ASA 61gray FRONT VIEW SIDE VIEW
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 50 Total loss 2080W
Primary (Volts) 600 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 425 / 193
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 137W
KVA 50 Total loss 2080W
Primary (Volts) 480 Noise level 45dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.8
Efficiency = 97.98%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 425 / 193
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
3
terminal boards 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 200W
KVA 75 Total loss 2800W
Primary (Volts) 600 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.7
Efficiency = 98.27%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 520 / 237
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 200W
KVA 75 Total loss 2800W
Primary (Volts) 480 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.7
Efficiency = 98.27%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 520 / 237
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
27"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
1
11 4" 2"
- Ground lug provided
23" 153 8"
- Leads brought-up and solidly positioned into separate
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: WALL / FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 350W
KVA 112.5 Total loss 3438W
Primary (Volts) 600 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 3.8
Efficiency = 98.35%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 820 / 375
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
361 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
- Ground lug provided 13 8" 13 8" 2"
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 350W
KVA 112.5 Total loss 3438W
Primary (Volts) 480 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 3.8
Efficiency = 98.35%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 820 / 375
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
361 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
- Ground lug provided 13 8" 13 8" 2"
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 422W
KVA 150 Total loss 4042W
Primary (Volts) 600 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.53%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 995 / 451
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
361 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
13 8" 13 8" 2"
- Ground lug provided
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 422W
KVA 150 Total loss 4042W
Primary (Volts) 480 Noise level 50dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.53%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 995 / 451
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
361 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 2"
13 8" 13 8" 2"
- Ground lug provided
- Leads brought-up and solidly positioned into separate 2712" 155 8"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 610W
KVA 225 Total loss 6058W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.55%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1450 / 658
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
463 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 112" 112"
- Ground lug provided 7
7
8" 8"
- Leads brought-up and solidly positioned into separate
terminal boards 33" 211 4"
- CSA enclosure: ventilated painted ASA 61gray 3
4"
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 610W
KVA 225 Total loss 6058W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.55%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1450 / 658
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
463 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure 112" 112"
- Ground lug provided 7
7
8" 8"
- Leads brought-up and solidly positioned into separate
terminal boards 33" 211 4"
- CSA enclosure: ventilated painted ASA 61gray 3
4"
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 790W
KVA 300 Total loss 7790W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.6%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1810 / 821
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
35" 2412"
Primary connectors per phase : 4/0-350MCM(S)
Secondary connectors per phase: 4/0-750MCM(D)
463 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
112" 112"
7 7
- Ground lug provided 8" 8"
- Leads brought-up and solidly positioned into separate 33" 211 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 790W
KVA 300 Total loss 7790W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.0
Efficiency = 98.6%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 1810 / 821
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
35" 2412"
Primary connectors per phase : 4/0-350MCM(S)
Secondary connectors per phase: 4/0-750MCM(D)
463 4"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
112" 112"
7 7
- Ground lug provided 8" 8"
- Leads brought-up and solidly positioned into separate 33" 211 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1100W
KVA 450 Total loss 10,100W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.3
Efficiency = 98.68%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2550 / 1157
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 341 4" 301 4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1100W
KVA 450 Total loss 10,100W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.3
Efficiency = 98.68%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2550 / 1157
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards 341 4" 301 4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA FRONT VIEW SIDE VIEW
C802.2 / NEMA TP-1
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
MOUNTING: FLOOR
- Copper windings
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1200W
KVA 500 Total loss 10,220W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.69%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2760 / 1252
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
1" 1" 1" 1"
- Leads brought-up and solidly positioned into separate 341 4" 301 4"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1200W
KVA 500 Total loss 10,220W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.69%
Insulation Class
(As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 2760 / 1252
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
1" 1" 1" 1"
- Leads brought-up and solidly positioned into separate 341 4" 301 4"
terminal boards 3
4"
- CSA enclosure: ventilated painted ASA 61gray
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1 FRONT VIEW SIDE VIEW
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1280W
KVA 600 Total loss 10,300W
Primary (Volts) 600 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.8%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 3150 / 1429
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate 1" 1" 1" 1"
341 4" 301 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date
Marcus Transformer LTD
DESCRIPTION PERFORMANCE
Type DRY TYPE DISTRIBUTION (ANN) No load loss 1280W
KVA 600 Total loss 10,300W
Primary (Volts) 480 Noise level 55dB
Secondary (Volts) 208Y / 120
Phase 3
Enclosure NEMA 1 EFFICIENCY
Impedance (%z) 4.1
Efficiency = 98.8%
Insulation Class (As per CSA C802.2 &
Temperature Rise NEMA TP-1)
Frequency 60Hz
Weight (LBS/KG) 3150 / 1429
Connection Dyn1(TT-1)
PHYSICAL DIMENSIONS
BIL. 10KV
515 8"
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate 1" 1" 1" 1"
341 4" 301 4"
terminal boards
3
- CSA enclosure: ventilated painted ASA 61gray 4"
Customer / PO
COMMENTS
Project
Engineer
Contractor
Revision Date