Beruflich Dokumente
Kultur Dokumente
Procure
3.2 ment
Data
Pump Pump
Design & DIN EN
Design &
Vendor to ISO
1 Manufact Manufact 2858/ISO
specify
uring uring 5199
Standard Standard
- Type &
MOC of Not Not Not
Gland Applicable Applicable Applicable
Packing
- External
Gland Required /
Not Not Not
Sealing Not
Applicable Applicable Applicable
Arrange Required
ment
- External
Gland
Sealing
Arrange Required / Not Not Not
ment Not Applicable Applicable Applicable
with Required
Lantern
Ring
- Cooling
Media
Not Not Not
Nozzle
Applicable Applicable Applicable
Requirem
ent
- Cooling
Media Not Not Not
Cumtr/Hr
Requirem Applicable Applicable Applicable
ent
- Cooling
Media
Not Not Not
Pressure Kg/Sqcm
Applicable Applicable Applicable
Requirem
ent
- Gland
Plate Not Not Not
Constructi Applicable Applicable Applicable
on Design
If
Mechanic
14 al Seal
then
- Type of
Vendor to
Mechanic SINGLE
specify
al Seal
- Make of Eagle EBIL/HI
EBIL
Seal Burgmann FAB
- Seal Vendor to Confirm
11,61
Plan specify Later On
- Flushing Vendor to Confirm
DDE
Media specify Later On
- Flushing
Media Vendor to Confirm
Temperat Deg C specify
DDE
Later On
ure
- Flushing
Vendor to Confirm
Media Kg/Sqcm DDE
specify Later On
Pressure
- Flushing
Vendor to Confirm
Media Cumtr/Hr DDE
specify Later On
Flow
Impeller
with Lock
19 Lock Nut Lock Nut Lock Nut
Nut or
Threaded
If
Impeller
20 with Lock
Nut then
- No. of Vendor to
1 1
Lock Nut specify
Impeller
Required / NOT
with Vendor to
21 Wear Not specify
Confirm REQUIRE
Ring Required D
Volute
Casing Required / NOT
Vendor to
22 with Not Confirm REQUIRE
specify
Wear Required D
Ring
Details of
23 Jacket if
Required
- Type of Not Not Not
Jacket required required required
-
Thicknes
s of
Jacket
Not Not Not
Sheet if
Applicable Applicable Applicable
Multi
Fabricate
d with
Sheet
-
Thicknes
s of
Casted
Jacket
Not Not Not
Piece if
Applicable Applicable Applicable
Single
Fabricate
d with
Casted
Jacket
- Jacket
with
Threaded
Not Not Not
Inlet &
Applicable Applicable Applicable
Outlet
connectio
n
Material
of
24 Construct
ion of
Pump
Wetted
a SS 316 CS
Parts
- Volute
SS 316 CS SS
Casing
- Volute
Casing NOT
Vendor to
Wear SS316 REQUIRE
specify
Ring Lock D
Screws
- Volute
NOT
Casing Vendor to
SS316 REQUIRE
Wear specify
Ring D
- Impeller SS 316 CS SS
- Impeller NOT
Vendor to
Wear SS316 REQUIRE
specify
Ring D
- Impeller
NOT
Wear Vendor to
SS316 REQUIRE
Ring Lock specify
Screws D
- Impeller Vendor to
SS316 SS410
Lock Nut specify
- Stuffing Vendor to
CS SS
Box specify
- Gland
Plate if
NOT
Pump Vendor to
NA REQUIRE
with specify
Gland D
Packing
Non
b Wetted SS 316 MS MS
Part
- Bearing Vendor to
CI CI
Housing specify
Vendor to
- Shaft SS410 45C8
specify
- Shaft Vendor to
SS410 45C8
Key specify
NA (part
- Shaft Vendor to
of Mech SS316
Sleeve specify
Seal)
Pump
50NB
Discharg
Vendor to ASME B
25 e Flange 32MM
specify 16.5 CL
Size with
Standard 150
Pump
80NB
Suction
Vendor to ASME B
26 Flange 50MM
specify 16.5 CL
Size with
Standard 150
Pump
27 Power - BKW / HP Vendor to 5.76 kW 6.57
specify
BKW
Shut Off Vendor to
28 Head Mtr specify
38.08 m 41.96
Motor Vendor to
29 KW / HP 11/14.75 7.5
Rating specify
Lubricato Grease /
30 Oil Oil
n Type Oil
Foundati
on frame
Material
31 MS MS MS
of
Construct
ion
Pump
Performa PERFOR
nce Curve
32 confirm MANCE
& Hydro Required Required CURVE
Test
Report
Pump
Operatio
n&
33 confirm YES
Maintena Required Required
nce
Manual
Third
Party
Test
Report of
Material Not
of
34 confirm Applicabl
Construct Required Required e
ion along
with
Chemical
Composit
ion
Foundati
35 on bolt Yes Yes Yes
Required
Make of
36 SKF SKF KSB STD
Bearing
Pump
Operatin
5.1 mm
37 g MM/Sec <4.5 <80 DB
/sec
Vibration
Limit
Bare
38 Weight of Kg 52
Pump
Pump
Cross
Sectional
View
39 Required Required Provided YES
with
Parts
Detail
Required