Beruflich Dokumente
Kultur Dokumente
Requirement :
= 51.92 mm
- Ln/180
≥ 76.20 mm
- Govern = 76.20 mm
- Design = 175 mm
- Chk* = OK
N
Calculation of Pinned Connection for Precast Concrete Girder
(Seated with Grouted)
Potential Crack at Precast Support
Calculation of Pinned Connection for Precast Concrete Girder
(Seated with Grouted)
*) Dimension check according to ACI 318-14 Ch.16 Sect. 16.5 (Assumed as Corbel/Bracket)
- Vu/ɸ = 58362 kg
- Chk* = shall not exceed the least of value as stated in Ch.16 Sect. 16.5.2.5
= 204960 kg
= OK
*) Reinforcement Check
- Nuc/ɸ = 13896 kg ; double axial force occurs caused by eccentric bending moment
- Nn = 218345 kg ; ACI 318-14 Ch.16 Sect. 16.5.4.3
- Chk* = OK for Tension
- Vuc/ɸ = 116724 kg ; double shear force caused by side by side precast girder
- Vn = 121130 kg ; ACI 318-14 Ch.22
- Chk* = OK for Shear