A15-A8 :-These are the higher order address lines store only address,Here we put the higher order
address.
AD7-AD0 :-These are the lower order address lines.This is a multi plexed Address/Data bus.Firstly we
store lower order address in this and after that we put data in it.
ALE :- It is a positive going pulse which indicates that the bits on AD7-AD0 are address bits.This latches
lower order bus and generate to seperate 8 address lines.
IO/M bar:-These are the status signals .Different signals give different results.
So this is the description of the timing diagram.Now we will know how to find the T states.
So for any instruction LDA,MVI,MOV ......etc.we have to fetch the operation code,for this the
microprocessor goes to the memory location where it will find the machine code for that opcode.From
this whatever has been there on the address goes through data bus to the instruction decoder which
decodes the signal.
So ,memory location 5000 in Hexa & machine code which is there for MVI is 00111110(assume only) ,ie
3E in Hexa.
For op code fetch the status signals are(IO/M=0,S1=1,S0=1),it places the memory address from
program counter on the address bus and increment the program counter to 5001.Thus,50 H goes to
higher order bus and 00H goes to lower order bus.The Ale signal goes high during T1 which latches
the lower order bus.At T2 the 8085 asserts RD bar signal,which enables the memory,and the memory
places the byte 3E on the data bus.Then 8085 places opcode in the instruction register and disables
RD bar signal.The fetch cycle is completed in T3 state.During T4 state 8085 decodes the opcode.
and finds out second byte to read.After the T3 state,the contents of the bus A15-A8 are unspecified and
AD7-AD0 goes high impedance.
For opcode fetch 4T states required.
After the opcode fetch 8085 goes again to the memory and places the next address 5001 on the
address bus and increments the program counter.The second signal identifies as memory read thus,the
status signals are (IO/M=0,S1=1, S0=0),the same thing happen as
it has been for opcode accept the decode.So for reading 3T states are required.
AS general rule :-
If there is 1 byte instruction we will require minimum 4T states.
If there is 2 byte instruction we will require minimum 7T states.
If there is 3 byte instruction we will require minimum 10T states.
Thus in above example which is 2 byte instruction we will require 4T states for opcode fetch and then
3T states for reading the data.Thus total 7T states.