How to Upload Packaging


Specifications with /SCWM/IPU
© Copyright 2012 SAP AG. All rights reserved. Business Objects and the Business Objects logo,
BusinessObjects, Crystal Reports, Crystal Decisions, Web
No part of this publication may be reproduced or transmitted in any
Intelligence, Xcelsius, and other Business Objects products and
form or for any purpose without the express permission of SAP AG.
services mentioned herein as well as their respective logos are
The information contained herein may be changed without prior
trademarks or registered trademarks of Business Objects
notice.
Software Ltd. Business Objects is an SAP company.
Some software products marketed by SAP AG and its distributors
Sybase and Adaptive Server, iAnywhere, Sybase 365, SQL
contain proprietary software components of other software vendors.
Anywhere, and other Sybase products and services mentioned
Microsoft, Windows, Excel, Outlook, PowerPoint, Silverlight, and herein as well as their respective logos are trademarks or
Visual Studio are registered trademarks of Microsoft Corporation. registered trademarks of Sybase Inc. Sybase is an SAP company.
IBM, DB2, DB2 Universal Database, System i, System i5, System p, Crossgate, m@gic EDDY, B2B 360°, and B2B 360° Services are
System p5, System x, System z, System z10, z10, z/VM, z/OS, registered trademarks of Crossgate AG in Germany and other
OS/390, zEnterprise, PowerVM, Power Architecture, Power Systems, countries. Crossgate is an SAP company.
POWER7, POWER6+, POWER6, POWER, PowerHA, pureScale,
All other product and service names mentioned are the
PowerPC, BladeCenter, System Storage, Storwize, XIV, GPFS,
trademarks of their respective companies. Data contained in this
HACMP, RETAIN, DB2 Connect, RACF, Redbooks, OS/2, AIX,
document serves informational purposes only. National product
Intelligent Miner, WebSphere, Tivoli, Informix, and Smarter Planet
specifications may vary.
are trademarks or registered trademarks of IBM Corporation.
These materials are subject to change without notice. These
Linux is the registered trademark of Linus Torvalds in the United
materials are provided by SAP AG and its affiliated companies
States and other countries.
("SAP Group") for informational purposes only, without
Adobe, the Adobe logo, Acrobat, PostScript, and Reader are representation or warranty of any kind, and SAP Group shall not
trademarks or registered trademarks of Adobe Systems Incorporated be liable for errors or omissions with respect to the materials.
in the United States and other countries. The only warranties for SAP Group products and services are
those that are set forth in the express warranty statements
Oracle and Java are registered trademarks of Oracle and its affiliates.
accompanying such products and services, if any. Nothing herein
UNIX, X/Open, OSF/1, and Motif are registered trademarks of the should be construed as constituting an additional warranty.
Open Group. These materials are provided “as is” without a warranty of any
kind, either express or implied, including but not limited to, the
Citrix, ICA, Program Neighborhood, MetaFrame, WinFrame, implied warranties of merchantability, fitness for a particular
VideoFrame, and MultiWin are trademarks or registered trademarks purpose, or non-infringement.
of Citrix Systems Inc. SAP shall not be liable for damages of any kind including without
limitation direct, special, indirect, or consequential damages that
HTML, XML, XHTML, and W3C are trademarks or registered
may result from the use of these materials.
trademarks of W3C®, World Wide Web Consortium, Massachusetts
SAP does not warrant the accuracy or completeness of the
Institute of Technology. information, text, graphics, links or other items contained within
Apple, App Store, iBooks, iPad, iPhone, iPhoto, iPod, iTunes, Multi- these materials. SAP has no control over the information that
you may access through the use of hot links contained in these
Touch, Objective-C, Retina, Safari, Siri, and Xcode are trademarks or materials and does not endorse your use of third party web pages
registered trademarks of Apple Inc. nor provide any warranty whatsoever relating to third party web
pages.
IOS is a registered trademark of Cisco Systems Inc.
SAP NetWeaver “How-to” Guides are intended to simplify the
RIM, BlackBerry, BBM, BlackBerry Curve, BlackBerry Bold, product implementation. While specific product features and
BlackBerry Pearl, BlackBerry Torch, BlackBerry Storm, BlackBerry procedures typically are explained in a practical business
Storm2, BlackBerry PlayBook, and BlackBerry App World are context, it is not implied that those features and procedures are
the only approach in solving a specific business problem using
trademarks or registered trademarks of Research in Motion Limited. SAP NetWeaver. Should you wish to receive additional
Google App Engine, Google Apps, Google Checkout, Google Data information, clarification or support, please refer to SAP
Consulting.
API, Google Maps, Google Mobile Ads, Google Mobile Updater,
Any software coding and/or code lines / strings (“Code”)
Google Mobile, Google Store, Google Sync, Google Updater, Google
included in this documentation are only examples and are not
Voice, Google Mail, Gmail, YouTube, Dalvik and Android are intended to be used in a productive system environment. The
trademarks or registered trademarks of Google Inc. Code is only intended better explain and visualize the syntax and
phrasing rules of certain coding. SAP does not warrant the
INTERMEC is a registered trademark of Intermec Technologies correctness and completeness of the Code given herein, and SAP
Corporation. shall not be liable for errors or damages caused by the usage of
the Code, except if such damages were caused by SAP
Wi-Fi is a registered trademark of Wi-Fi Alliance.
intentionally or grossly negligent.
Bluetooth is a registered trademark of Bluetooth SIG Inc.
Motorola is a registered trademark of Motorola Trademark Holdings Disclaimer:
LLC. Some components of this product are based on Java™. Any code
Computop is a registered trademark of Computop change in these components may cause unpredictable and severe
Wirtschaftsinformatik GmbH. malfunctions and is therefore expressively prohibited, as is any
decompilation of these components.
SAP, R/3, SAP NetWeaver, Duet, PartnerEdge, ByDesign, SAP
BusinessObjects Explorer, StreamWork, SAP HANA, and other SAP Any Java™ Source Code delivered with this product is only to be
products and services mentioned herein as well as their respective used by SAP’s Support Services and may not be modified or
logos are trademarks or registered trademarks of SAP AG in altered in any way.
Germany and other countries.

i
Table of Contents
1. Purpose and Structure of this Document ......................................................................... 1
2. The Structure of the Input File ........................................................................................... 1
3. How to Set Up the Input File ............................................................................................... 4
4. Unsupported Fields ............................................................................................................. 5
5. Common Error Messages and Their Causes .................................................................... 5
6. Mapping of Fields to /SCWM/PACKSPEC ......................................................................... 5

ii
1. Purpose and Structure of this Document

The purpose of this document is to explain how to use the transaction /SCWM/IPU to upload
packaging specifications. This transaction reads a text file with data and creates the
packaging specifications accordingly. It turns out that the format is very technical and can be
difficult to handle. With this document, we try to remedy this problem by given a detailed
description of the input format and by providing a template to ease the manual entry of
data.
In the section The Structure of the Input File we explain how to format the input file, i.e. how
to structure the data for the new packaging specifications.
The following section How to Set Up the Input File shows how the attached template can help
to create the input file.
The last section Mapping of Fields to /SCWM/PACKSPEC establishes the connection between
the technical names used in the input file and the corresponding fields in the packaging
specification as shown in transaction /SCWM/PACKSPEC.

2. The Structure of the Input File

The input file needs to be a text file, which may contain multiple packaging specifications.
Each packaging specification is described by several differently structured lines, whose
structure is indicated by their first letter:
" " - records with "blank" in the first position are ignored
"*" - contains a comment that will be printed on the output
"H" - header data - structure /SCWM/S_PS_DL_HEADER
"C" - content data - structure /SCWM/S_PS_DL_CONTENT
"L" - level data - structure /SCWM/S_PS_DL_LEVEL
"E" - level element data - structure /SCWM/S_PS_DL_LEVEL_ELEMENT
"R" - condition record - structure /SCWM/S_PS_DL_CONDITION

An entry for a packaging specification needs to start with a header line followed by all the
other lines for this packaging specification.
The lines starting with H, C, L, E, and R contain the field values of the corresponding
structure written consecutively without any spaces. Transaction SE11 can be used to display
the fields of a structure. The field names in the structure are the technical names; in order to
know which field corresponds to which field of a packaging specification as displayed in
/SCWM/PACKSPEC, please consult the section Mapping of Fields to /SCWM/PACKSPEC.
All structures begin with the following key fields (included structure /SCWM/S_PS_DL_KEY):

DL_RECTYPE /SCWM/DE_PS_DL_RECTYPE CHAR 1


DL_PS_SEQ /SCWM/DE_PS_SEQ CHAR 8
DL_LEVEL_SEQ CHAR 2
DL_REC_SEQ CHAR 8
DL_FILLER CHAR 1

 DL_RECTYPE is the letter indicating what the line specifies (H,C,L,E,R,*,” “).
 DL_PS_SEQ must contain a different, consecutive number for each packaging
specification in the file. All lines belonging to the first packaging specification in the
file should have DL_PS_SEQ equal to 1, all lines for the second should have PS_SEQ
equal to 2, etc.
 DL_LEVEL_SEQ is only relevant for lines starting with L (levels) and E (elements), in all
other cases it is recommended to set it to 1. So the line for the first level should have
1, for the second level 2, for the third level 3. The lines for the elements of the first
level should all have 1, the lines for the elements of the second level 2 should all have
2, etc.
 DL_REC_SEQ is only relevant for lines starting with C (content) or E (elements), in all
other cases it is recommended to set it to 1. Content lines are consecutively
numbered. For a given level, the elements have to be enumerated using this field.
Example: If level 5 has three different elements, then the first element should have
DL_REC_SEQ equal to 1, the second equal to 2 and the third equal to 3.
 DL_FILLER serves only as a visual separator and can be left empty.

So the entry for a certain packaging specification might look like this (with only the keys
filled for now):

H 5 1 1
C 5 1 1
C 5 1 2
L 5 1 1
L 5 2 1
L 5 3 1
E 5 1 1
E 5 2 1
E 5 2 2
E 5 2 3
E 5 3 1
E 5 3 2
R 5 1 1
R 5 1 1
It is important to add the correct number of spaces if an entry is shorter than the
maximal length. In the above example, DL_PS_SEQ is a CHAR of length 8, however the
value “5” only occupies one character, so we need to add seven spaces on its left.

All entries have PS_SEQ = 5, so they all belong to the fifth packaging specification in the file.
There are two contents enumerated by DL_REC_SEQ and three levels enumerated by
DL_LEVEL_SEQ. There are six elements: the first has DL_LEVEL_SEQ = 1, so it belongs to level
1. The next three belong to level 2 and the last two to level 3. For each level, the elements
are ordered by DL_REC_SEQ. The condition records are not ordered.

So how does one fill the remaining fields? Let us illustrate this for the content line. We first
look up the structure /SCWM/S_PS_DL_CONTENT in SE11 and see that it has the following
fields:

MATID CHAR 22
MATNR CHAR 40
UNIT /SCWM/DE_UNIT UNIT 3
QUAN CHAR 31
MEINS MEINS UNIT 3
REFMIX /SCWM/DE_REFMIX CHAR 1
BATCHMIX /SCWM/DE_BATCHMIX CHAR 1
SUB_PS_ID /SCWM/DE_PSID CHAR 20

In order to make sense of the technical names, we first look at the section “Mapping of fields
to /SCWM/PACKSPEC” to identify the fields; this section also tell us that SUB_PS_ID should
not be filled and we only need to provide one of the two fields MATID/MATNR. Then we
complete the first content line with the correct data:

C 5 1 1 AAAAAAAAAAAAAAAAAAAAAABBBBBBBBBBBBBBBB…

Here MATID is “AAAAAAAAAAAAAAAAAAAAAA”, MATNR is


“BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB”, etc.

As a basic rule, only fields that have non-initial values should be filled in the input file.
In particular, initial numerical fields like QUAN should be left empty; it is not
necessary to fill them with “0”.

This procedure needs to be repeated analogously for the other line types until the entry is
complete. If you enter the data manually, it is recommended to use the template as
described in the next section. Depending on the data format of the legacy packaging
specifications, it may be more convenient to automatize the creation of the input file.
3. How to Set Up the Input File

As another attachment to this note, you will find an example input file. If the input file is to
be set up manually, it is recommended to use the example entries as a template, because
they contain comments to structure the file and indicate the position of each field. Here is a
snippet from the file:

**************************************************************
* PROD-S01 (Small parts)
* This is an example packaging specification
* for a small product…
**************************************************************
PS_SEQ L REC_SEQ| PS_ID (…)
H 1 1 1 PROD-S01
PS_SEQ L REC_SEQ| MATID (…)
C 1 1 1 PROD-S01
PS_SEQ L REC_SEQ| D TRGQTY MINQTY RNDQTY| HUT (…)
L 1 1 1 1 900 2C1
L 1 2 1 2 900 4E1
PS_SEQ L REC_SEQ| MATID (…)
E 1 1 1 CARTON_S
E 1 2 1 EUROPALLET
PS_SEQ L REC_SEQ| KOTABNR KSC VALID_F VALID_T P (…)
R 1 1 1 SAPPAL010PAL201206012999123101
R 1 1 1 SAPWHTA10WHT201206012999123101

The entry contains a title comment to indicate that the following entries belong to the same
packaging specification and to give a brief description. Above each different line type a
comment line has been added to indicate the position of the fields. The field name is always
directly above the position of its value; the spaces for the value end exactly where the field
name ends. Short field names have sometimes been abbreviated due to lack of space and
one-character-fields have been commented with the pipe symbol “|”. For example, the
“level” lines have the following comments and structure:

PS_SEQ L REC_SEQ| D TRGQTY MINQTY RNDQTY| HUT (…)


L 1 1 1 AABBBBBBBBBBCCCCCCCCCCDDDDDDDDDDEFFFF…

The field DISPLAY_SEQ corresponds to the space AA, TRGQTY to the space BBBBBBBBBB,
etc. Using this commented structure should ease the manual entry of packaging
specifications and help you avoid off-by-one errors and the like.
4. Unsupported Fields

Certain fields are included in the line structures, but they cannot be set via the transaction
/SCWM/IPU. Since they have no effect anyway, it is recommended to always leave them
blank in the input files. These fields are:

/SCWM/S_PS_DL_HEADER
-CREATED_BY
-CREATED_AT
-CHANGED_BY
-CHANGED_AT
-ORIG_SYSTEM

/SCWM/S_PS_DL_CONTENT
- SUB_PS_ID

5. Common Error Messages and Their Causes

 “File record 11: NUMERIC_CONVERSION_ERROR”


In line 11, some field is shifted too far to the left or right, usually a character-like
entry is inside a numeric field.
 “File C:\...\example.txt could not be opened”
Probably “Transfer Data” was selected instead of “Upload” in the selection screen.

6. Mapping of Fields to /SCWM/PACKSPEC

The purpose of this section is to provide a “dictionary” that lets you look up quickly which
fields in the packaging specification correspond to which technical names in the input file.
For example, if you want to set the field “Rounding Method” in the header, you can look at
the screen shots in the header section below to see that the corresponding technical name is
ROUNDING_GOAL.
To display a packaging specification, start transaction /SCWM/PACKSPEC. On the first screen,
select the packaging specification and double-click on the selected row to display the detail
view. The view consists of a tree structure on the left-hand side illustrating the hierarchical
structure of the packaging specifications. By clicking on the components in the tree structure
you can display the corresponding data in the right-hand screen.
In the following, we will illustrate how the data in the input file for /SCWM/IPU correspond
to the fields displayed in /SCWM/PACKSPEC.

/SCWM/S_PS_DL_HEADER
To display the header data, click on the number of the packaging specification in the tree
structure. The fields for which can be passed in the header line are spread over three
different tabs. The first one is the “Org. Data” tab.
It is important to note that even though the fields CREATED_BY, CREATED_AT,
CHANGED_BY, CHANGED_AT, and ORIG_SYSTEM are included in the structure, they cannot
be set via /SCWM/IPU. Since they have no effect, it is recommended that they should always
be left empty.
More header data is located on the tab „Rounding“.

And finally, there is also a field on the tab „Documents”.


/SCWM/S_PS_DL_CONTENT
In the tree structure, navigate to Content > Product. The fields which can be entered for the
content are the following.

The fields MATID and SUB_PS_ID are not displayed. For better transparency, either MATID
or MATNR should be used – not both. Setting SUB_PS_ID has no effect, so the field should
always be left empty.

/SCWM/S_PS_DL_LEVEL
The level structure is the most complex. Click on the level entry in the tree structure to
display the data. The fields are spread over several tabs, most of them on the tab “Weight,
Vol. & Dim.”.
Other fields are located on the tab “Warehouse”…
… as well as the tab “Rounding”...
… and finally the tab “Text”.

The field FILL_UP is only displayed in the tree structure entry of the level:

/SCWM/S_PS_DL_LEVEL_ELEMENT
The elements are situated below the levels in the tree structure and can also be found on
the tab “Assigned Elements” in the level display.
The field MATID is not displayed. For better transparency, either MATID or MATNR should be
used – not both.

/SCWM/S_PS_DL_CONDITION
The condition records are displayed in the header, under the tab “Determination”. The detail
view for a condition record looks as follows.
The structure contains dynamic fields FIELDNAME01 to FIELDNAME02 with their
corresponding VALUE01 to VALUE15. These fields depend on the configuration of the
condition. In our example file, the fields PAK_LOCNO and PAK_MATNR are used.