SECTION 2 System Specification for Cathelco Anodic

2.1 System size calculation


3
Sea Water to be Treated 2 x Sea chests flow rate = 170m /hr (max)

Anode Location 1 x MG/TC to be fitted in each of 2 sea chests

Pipe work material Steel

Anode Life/Renewal every 1 year

When re-ordering please quote drawing No. 109913M/94704


And the anode part number from table 2.3

2.2 Current Settings


The current settings which appear below should be used in most circumstances. If, however, there continue
to be signs of fouling, refer to Section 8.2 for guidance on current settings.

In Operation Not In Operation


Sea chest Anode Ref Current Settings Current Settings
± 0.02 ± 0.02
3
Sea Chest 1 - 170m /hr (max)
MG 1 0.28 amps 0.20 amps
CA094704MGTCA
TC 1 0.28 amps 0.20 amps
3
Sea Chest 2 - 170m /hr (max)
MG 2 0.28 amps 0.20 amps
CA094704MGTCA
TC 2 0.28 amps 0.20 amps

The actual life of the anode depends on the actual operation of the system; the above stated values
assume continuous current setting and should be used as a guide.

The higher the current setting the shorter the anode life. The lower the current setting the
greater the anode life.

Installation Kit
Each new system is supplied with an Installation Kit which are specific to the equipment that has been
supplied.
On Board Spares - Consumables
2 off fuses for control panel modules and 2 off fuses for control panel power unit, spare fuses fixed to inside
rear of control panel casing.