CLIENT LINDE INDIA LIMITED, KOLKATA
Equipment INSTRUMENT AIR DRYER PACKAGE
P.O. No 503833 dtd. 11-Jan-2019
Subject DRYER SIZING CALCULATION FOR INSTRUMENT AIR DRYER PACKAGE
Status Rev. Sl No EIL Comments M/s Indcon's / linde Response
General Comment: Linde to confirm that all the input values for various parameters,
references and calculations done are correct. This document is kept for information Calrifications are as below
1
however some observations have been marked here. Linde to provide clarifications for the
same in revised document.
Pressure is not required to be considered. We have converted
2 Why pressure is not considered? Nm3/hr. to Sm3/hr. Pressure is atmospheric pressure, hence no
pressure correction is required.
3 To be confirmed by Linde in consultation with Compressor Vendor It is confirmed to size the dryer fro 40 deg. C
It is the input from desiccant manucaturer. Letter from desiccant
4 From where this value is taken? manucaturer is enclosed.
5 Ws in required desiccant qty. Corrected
It is the input from desiccant manucaturer. Letter from desiccant
6 Basis of these values? manucaturer is enclosed.
What are these values? it is being revised. This is for hot air inlet temp. We calculate how
13 much would be the heater rating based on hot air inlet temp.
14 Basis? Of the power consumption value This is heater rating selected x heating time
15 What is this value? This will be revised based on the hot air inlet temp.
16 What is Ca? specify this is Cp. Will be corrected in revised calculcation.
How is this value calculated? The formulae is already shown just above your comment under the
17 heading of regeneration air flow rate
How is this value calculated? This is calculated based on 15.6 deg. Temp. as per
18 (905*(15.6+273)/273)