Sie sind auf Seite 1von 26

PROJECT: TOTAL VISTA DEVELOPMENT SDN BHD

FILE NO: IWK/C/PP2/07/106


SHEET:
CHECKING SEWER CAPACITY & VELOCITY :
Colebrook-Whiter Eq:
v=−2√2𝑔𝐷𝑠 log[ 𝑘𝑠/3.7𝐷+ 2.5𝑣/(𝐷√2𝑔𝐷𝑠))

v = kinematic velocity = 0.0000008 at 30°C

1) Colebrook - White Equation (New pipe VCP, ks = 0.06 mm)


MH48M - MH48L
Pipe Diameter (D) m 0.225 0.225

Downstream IL. m 10.548 10.068

Upstream IL. m 10.068 9.699

Distance m 48 48

Gradient (S) 1 / X 100 130 #DIV/0! #DIV/0! #DIV/0!

Capacity (Full Flow) Q mᶟ/s 0.066 0.057 #DIV/0! #DIV/0! #DIV/0!

Velocity (V) m/s 1.656 1.444 #DIV/0! #DIV/0! #DIV/0!

1) Colebrook - White Equation (Old pipe VCP, ks =1.5 mm)


MH48M - MH48L 0 0 0 0
Pipe Diameter (D) m 0.225 0.225 0 0 0

Downstream IL. m 10.548 10.068 0 0 0


Upstream IL. m 10.068 9.699 0 0 0

Distance m 48 48 0 0 0

Gradient (S) 1 / X 100 130 #DIV/0! #DIV/0! #DIV/0!

Capacity (Full Flow) Q mᶟ/s 0.046 0.040 #DIV/0! #DIV/0! #DIV/0!

Velocity (V) m/s 1.149 1.007 #DIV/0! #DIV/0! #DIV/0!


#DIV/0!

#DIV/0!

#DIV/0!

0
0

0
0

#DIV/0!

#DIV/0!

#DIV/0!
HYDRAULIC DESIGN CALCULATION
UNTUK: TOTAL VISTA DEVELOPMENT SDN BHD FOR: MH9/K5 to MH9/D

Flow Computation Pipe Computation (new pipe) Manhole & Level Computation
ks: VC = 0.06 mm, RC = 1.5mm
MH to PE Cumulative Average Peak Flow Peak Comulative Dia, Ø Length Gradient Full Pipe Full Pipe Fall Ground IL. Depth
MH PE Flow Factor Flow Peak Flow 1:S Velocity Flow Level of Pipe
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16)
MH No. (PE) (PE) (l/s) (l/s) (l/s) (mm) (m) (m/s) (l/s) (m) (m) (m)
MH9/K5 2.5 1.300 1.200
0 0 0.00 0.00 0.00 0.00 225 60 200 0.81 32.259 0.3
MH9/K4 2.5 1.000 1.500
938 938 2.44 4.73 11.56 11.56 225 39 200 1.15 45.843 0.195
MH9/K3 2.5 0.805 1.695
0 938 2.44 4.73 11.56 11.56 225 24 200 1.15 45.843 0.120
MH9/K2 2.5 0.685 1.815
937 1875 4.88 4.39 21.42 21.42 225 15 200 1.15 45.843 0.075
MH9/K1 2.5 0.610 1.890
0 1875 4.88 4.39 21.42 21.42 225 8 200 1.15 45.843 0.040
MH9/K 2.5 0.570 1.930
372 2247 5.85 4.30 25.16 25.16 225 8 200 1.15 45.843 0.040
MH9/J 2.5 0.530 1.970
0 2247 5.85 4.30 25.16 25.16 225 34 200 1.15 45.843 0.170
MH9/I 2.5 0.360 2.140
0 2247 5.85 4.30 25.16 25.16 225 22 200 1.15 45.843 0.110
MH9/H 2.5 0.250 2.250
0 2247 5.85 4.30 25.16 25.16 225 6 200 1.15 45.843 0.030
MH9/G 2.5 0.220 2.280
10 2257 5.88 4.30 25.26 25.26 225 33 200 1.15 45.843 0.165
MH9/F 2.5 0.055 2.445
20 2277 5.93 4.29 25.46 25.46 225 34 200 1.15 45.843 0.170
MH9/E 2.5 -0.115 2.615
80 2357 6.14 4.28 26.25 26.25 225 46 200 1.15 45.843 0.230
MH9/D 2.5 -0.345 2.845
0 2357 6.14 4.28 26.25 26.25 225 13
P. Station
MANHOLE TYPE & SIZE REMARKS

1200mm Ø Precast Conc. Drop


600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
Drop
HYDRAULIC DESIGN CALCULATION
UNTUK: TOTAL VISTA DEVELOPMENT SDN BHD FOR: MH9/B5 to MH9/B and MH9/B1C to MH9/B1

Flow Computation Pipe Computation (new pipe) Manhole & Level Computation
ks: VC = 0.06 mm, RC = 1.5mm
MH to PE Cumulative Average Peak Flow Peak Comulative Dia, Ø Length Gradient Full Pipe Full Pipe Fall Ground IL. Depth
MH PE Flow Factor Flow Peak Flow 1:S Velocity Flow Level of Pipe
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16)
MH No. (PE) (PE) (l/s) (l/s) (l/s) (mm) (m) (m/s) (l/s) (m) (m) (m)
MH9/B5 2.5 1.300 1.200
30 30 0.08 6.91 0.54 0.54 225 55 200 1.15 45.843 0.275
MH9/B4 2.5 1.025 1.475
50 80 0.21 6.21 1.29 1.29 225 55 200 1.15 45.843 0.275
MH9/B3 2.5 0.750 1.750
165 245 0.64 5.49 3.50 3.50 225 58 200 1.15 45.843 0.290
MH9/B2 2.5 0.460 2.040
390 635 1.65 4.94 8.17 8.17 225 60 200 1.15 45.843 0.300
MH9/B1 2.5 0.160 2.340
0 635 1.65 4.94 8.17 8.17 225 16 200 1.15 45.843 0.080
MH9/B 2.5 0.080 2.420
0 635 1.65 4.94 8.17 8.17 225 8 -7 #VALUE! #VALUE! -1.220
MH9/B1C 2.5 1.300 1.200
80 715 1.86 4.88 9.08 9.08 225 51 200 1.15 45.843 0.255
MH9/B1B\ 2.5 1.045 1.455
65 780 2.03 4.83 9.81 9.81 225 51 200 1.15 45.843 0.255
MH9/B1A 2.5 0.790 1.710
65 845 2.20 4.79 10.54 10.54 225 49 200 1.15 45.843 0.245
MH9/B1 2.5 0.545 1.955
845 2.20 4.79 10.54 10.54 225 33 67 2.03 80.867 0.490
MH9/F 2.5 0.055 2.445
845 2.20 4.79 10.54 10.54 225 34 200 1.15 45.843 0.170
MH9/E 2.5 -0.115 2.615
845 2.20 4.79 10.54 10.54 225 46 200 1.15 45.843 0.230
MH9/D 2.5 -0.345 2.845
845 2.20 4.79 10.54 10.54 225 13
P. Station
to MH9/B1

MANHOLE TYPE & SIZE REMARKS

1200mm Ø Precast Conc. Drop


600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
Drop
HYDRAULIC DESIGN CALCULATION
UNTUK: TOTAL VISTA DEVELOPMENT SDN BHD FOR: MH9/B10 to MH9/B1, MH9/K3A to MH9/K3 and MH9/J1A to MH

Flow Computation Pipe Computation (new pipe) Manhole & Level Computation
ks: VC = 0.06 mm, RC = 1.5mm
MH to PE Cumulative Average Peak Flow Peak Comulative Dia, Ø Length Gradient Full Pipe Full Pipe Fall Ground IL. Depth
MH PE Flow Factor Flow Peak Flow 1:S Velocity Flow Level of Pipe
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16)
MH No. (PE) (PE) (l/s) (l/s) (l/s) (mm) (m) (m/s) (l/s) (m) (m) (m)
MH9/B10 2.5 1.300 1.200
95 95 0.25 6.09 1.51 1.51 225 54 200 1.15 45.843 0.27
MH9/B9 2.5 1.030 1.470
45 140 0.36 5.83 2.13 2.13 225 54 200 1.15 45.843 0.270
MH9/B8 2.5 0.760 1.740
40 180 0.47 5.68 2.66 2.66 225 55 200 1.15 45.843 0.275
MH9/B7 2.5 0.485 2.015
0 180 0.47 5.68 2.66 2.66 225 13 200 1.15 45.843 0.065
MH9/B6 2.5 0.420 2.080
0 180 0.47 5.68 2.66 2.66 225 51 200 1.15 45.843 0.255
MH9/B1 2.5 0.165 2.335
0 180 0.47 5.68 2.66 2.66 225 8 -7 #VALUE! #VALUE! -1.135
MH9/K3A 2.5 1.300 1.200
928 1108 2.89 4.65 13.41 13.41 225 60 200 1.15 45.843 0.300
MH9/K3 2.5 1.000 1.500
1108 2.89 4.65 13.41 13.41 225 22 -73 #VALUE! #VALUE! -0.300
MH9/J1A 2.5 1.300 1.200
1108 2.89 4.65 13.41 13.41 225 60 200 1.15 45.843 0.300
MH9/J1 2.5 1.000 1.500
1108 2.89 4.65 13.41 13.41 225 33 35 2.85 113.475 0.945
MH9/F 2.5 0.055 2.445
1108 2.89 4.65 13.41 13.41 225 34 200 1.15 45.843 0.170
MH9/E 2.5 -0.115 2.615
1108 2.89 4.65 13.41 13.41 225 46 200 1.15 45.843 0.230
MH9/D 2.5 -0.345 2.845
1108 2.89 4.65 13.41 13.41 225 13
P. Station
o MH9/K3 and MH9/J1A to MH9/J1

MANHOLE TYPE & SIZE REMARKS

1200mm Ø Precast Conc. Drop


600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
Drop
HYDRAULIC DESIGN CALCULATION
UNTUK: TOTAL VISTA DEVELOPMENT SDN BHD FOR: MH9/K1B to MH9/K1, MH9/J5 to MH9/J and MH9/A7 to MH9/A

Flow Computation Pipe Computation (new pipe) Manhole & Level Computation
ks: VC = 0.06 mm, RC = 1.5mm
MH to PE Cumulative Average Peak Flow Peak Comulative Dia, Ø Length Gradient Full Pipe Full Pipe Fall Ground IL. Depth
MH PE Flow Factor Flow Peak Flow 1:S Velocity Flow Level of Pipe
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16)
MH No. (PE) (PE) (l/s) (l/s) (l/s) (mm) (m) (m/s) (l/s) (m) (m) (m)
MH9/K1B 2.5 1.300 1.200
469 469 1.22 5.11 6.24 6.24 225 34 283 0.96 38.159 0.12
MH9/K1A 2.5 1.180 1.320
0 469 1.22 5.11 6.24 6.24 225 34 200 1.15 45.843 0.170
MH9/K1 2.5 1.010 1.490
0 469 1.22 5.11 6.24 6.24 225 24 -83 #VALUE! #VALUE! -0.290
MH9/J5 2.5 1.300 1.200
937 1406 3.66 4.53 16.58 16.58 225 34 200 1.15 45.843 0.170
MH9/J4 2.5 1.130 1.370
0 1406 3.66 4.53 16.58 16.58 225 20 200 1.15 45.843 0.100
MH9/J3 2.5 1.030 1.470
372 1778 4.63 4.41 20.43 20.43 225 16 200 1.15 45.843 0.080
MH9/J2 2.5 0.950 1.550
0 1778 4.63 4.41 20.43 20.43 225 25 200 1.15 45.843 0.125
MH9/J1 2.5 0.825 1.675
0 1778 4.63 4.41 20.43 20.43 225 11 200 1.15 45.843 0.055
MH9/J 2.5 0.770 1.730
0 1778 4.63 4.41 20.43 20.43 225 6 -14 #VALUE! #VALUE! -0.430
MH9/A7 2.5 1.200 1.300
20 1798 4.68 4.41 20.63 20.63 225 50 200 1.15 45.843 0.250
MH9/A6 2.5 0.950 1.550
20 1818 4.73 4.40 20.84 20.84 225 47 200 1.15 45.843 0.235
MH9/A5 2.5 0.715 1.785
0 1818 4.73 4.40 20.84 20.84 225 19 200 1.15 45.843 0.095
MH9/A1 2.5 0.620 1.880
MH9/J and MH9/A7 to MH9/A1

MANHOLE TYPE & SIZE REMARKS

1200mm Ø Precast Conc. Drop


600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
Drop
HYDRAULIC DESIGN CALCULATION
UNTUK: TOTAL VISTA DEVELOPMENT SDN BHD FOR: MH9/A4 to MH9/D

Flow Computation Pipe Computation (new pipe) Manhole & Level Computation
ks: VC = 0.06 mm, RC = 1.5mm
MH to PE Cumulative Average Peak Flow Peak Comulative Dia, Ø Length Gradient Full Pipe Full Pipe Fall Ground IL. Depth
MH PE Flow Factor Flow Peak Flow 1:S Velocity Flow Level of Pipe
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16)
MH No. (PE) (PE) (l/s) (l/s) (l/s) (mm) (m) (m/s) (l/s) (m) (m) (m)
MH9/A4 2.5 1.200 1.300
20 20 0.05 7.23 0.38 0.38 225 50 200 1.15 45.843 0.25
MH9/A3 2.5 0.950 1.550
20 40 0.10 6.70 0.70 0.70 225 46 200 1.15 45.843 0.230
MH9/A2 2.5 0.720 1.780
0 40 0.10 6.70 0.70 0.70 225 8 200 1.15 45.843 0.040 0.680
MH9/A1 2.5 0.620 1.880
0 40 0.10 6.70 0.70 0.70 225 29 200 1.15 45.843 0.145
MH9/A 2.5 0.475 2.025
635 675 1.76 4.91 8.63 8.63 225 59 200 1.15 45.843 0.295 0.180
MH9/B 2.5 0.080 2.420
0 675 1.76 4.91 8.63 8.63 225 43 200 1.15 45.843 0.215
MH9/C 2.5 -0.135 2.635
0 675 1.76 4.91 8.63 8.63 225 40 200 1.15 45.843 0.200
MH9/D 2.5 -0.335 2.835
0 675 1.76 4.91 8.63 8.63 225 22 -38 #VALUE! #VALUE! -0.585
MH9/H 2.5 0.250 2.250
0 675 1.76 4.91 8.63 8.63 225 6 200 1.15 45.843 0.030
MH9/G 2.5 0.220 2.280
10 685 1.78 4.90 8.74 8.74 225 33 200 1.15 45.843 0.165
MH9/F 2.5 0.055 2.445
20 705 1.84 4.88 8.97 8.97 225 34 200 1.15 45.843 0.170
MH9/E 2.5 -0.115 2.615
80 785 2.04 4.83 9.87 9.87 225 46 200 1.15 45.843 0.230
MH9/D 2.5 -0.345 2.845
0 785 2.04 4.83 9.87 9.87 225 13
P. Station
MANHOLE TYPE & SIZE REMARKS

1200mm Ø Precast Conc. Drop


600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
Drop
HYDRAULIC DESIGN CALCULATION
UNTUK: TOTAL VISTA DEVELOPMENT SDN BHD FOR: MH9/K5 to MH9/D

Flow Computation Pipe Computation (old pipe) Manhole & Level Computation
ks: VC = 0.06 mm, RC = 1.5mm
MH to PE Cumulative Average Peak Flow Peak Comulative Dia, Ø Length Gradient Full Pipe Full Pipe Fall Ground IL. Depth
MH PE Flow Factor Flow Peak Flow 1:S Velocity Flow Level of Pipe
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16)
MH No. (PE) (PE) (l/s) (l/s) (l/s) (mm) (m) (m/s) (l/s) (m) (m) (m)
Ex. MH 5 2993 2.5 1.300 1.200
1220 4213 10.97 4.01 44.02 44.02 225 60 200 0.81 32.259 0.3
Ex. MH 6 2.5 1.000 1.500
346.5 4559.5 11.87 3.98 47.23 47.23 225 39 200 0.81 32.259 0.195
Ex. MH 7 2.5 0.805 1.695
0 4559.5 11.87 3.98 47.23 47.23 225 24 200 0.81 32.259 0.120
Ex. MH 8 2.5 0.685 1.815
225.3 4784.8 12.46 3.96 49.30 49.30 300 15 300 0.80 56.527 0.075
Ex. MH 8/1 2.5 0.610 1.890
396.9 5181.7 13.49 3.92 52.92 52.92 300 8 300 0.80 56.527 0.040
Ex. MH 9 2.5 0.570 1.930
372 5553.7 14.46 3.89 56.29 56.29 300 8 300 0.80 56.527 0.040
Ex. MH 10 2.5 0.530 1.970
1140 6693.7 17.43 3.81 66.47 66.47 375 34 320 0.81 89.043 0.170
Ex. MH 11 2.5 0.360 2.140
0 6693.7 17.43 3.81 66.47 66.47 375 22 320 0.81 89.043 0.110
Ex. MH 12 2.5 0.250 2.250
0 6693.7 17.43 3.81 66.47 66.47 375 6 320 0.81 89.043 0.030
Ex. MH 13 2.5 0.220 2.280
215 6908.7 17.99 3.80 68.36 68.36 375 33 320 0.81 89.043 0.165
Ex. MH 14 2.5 0.055 2.445
20 6928.7 18.04 3.80 68.54 68.54 375 34
STP
MANHOLE TYPE & SIZE REMARKS

1200mm Ø Precast Conc. Drop


600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron
1200mm Ø Precast Conc. Drop
600mm Ø Ductile Iron

Das könnte Ihnen auch gefallen