Sie sind auf Seite 1von 1

West Bay Lagoon Villas

Q9971-1 Hot Water


V1

Project No. Date


Alpha MSH DESIGN CALCULATION

Mplumbing and Fire Fighting Department SHEET Sheet No. Computed by


Phnom Penh-Cambodia

Subject Hot Water Demand For Tower Checked by Approved by


Building Apartment

1- Tower

HW Demand Storage
Fixture type Occup NO Total Flow Storage Heater
Demand Factor Factor

lph / fix lph lph liter kW


Toilet
Lavatory Private 300 7.6 2280
Bath Tub Private 300 76 22800
Bidet Private 300 11 3300
Shower Private 300 284 85200
Dishwasher Private 0 57 0
Washing MachinPrivate 0 76 0
Kitchen Sink Private 0 38 0

SSS-SSSSS SSS,SSS S.SS S.S SS,SSS SS,SSS S,SSS


Total Possible max demand 113580 28,395 22,716 1,154

First Hour Probable max. demand 28395 lit/h


Required storage capacity = 22716 lit
Required heater capacity = 1154 kW

NB: Probable max demand = lph * Demand Factor


Required Storage Capacity = Probable max. demand* Storage Factor
Heater Capacity = (Storage capacity/3600)* 4.18*(60-25)

Q9971-1-CLC-ME-01-Rev A 1 of 1