GD33-12 12V33AH
GD SERIES-Deep Cycle Battery
Specification
Nominal Voltage 12V
Nominal Capacity(10HR) 33.0AH
Length 195 2mm (7.68 inches)
Width 130 2mm (5.12 inches)
Dimension
Container Height 155 2mm (6.10 inches)
Total Height (with Terminal) 180 2mm (7.09 inches)
Approx Weight Approx 9.6 Kg (21.1 Ibs)
Terminal T5 / T6 / T12
Container Mater ial ABS
35.4 AH/1.77A (20hr ,1.80V/cell,25℃/77℉)
Applications 33.0 AH/3.30A (10hr,1.80V/cell,25℃/77℉)
Rated Capacity 28.9 AH/5.79A (5hr,1.75V/cell,25℃/77℉)
Electric tools 26.2 AH/8.75A (3hr,1.75V/cell,25℃/77℉)
Vehicle in place of walking 21.3 AH/21.3A (1hr,1.60V/cell,25℃/77℉)
Lawn mowers Max. Discharge Current 495A (5s)
Golf trolleys and golf cart
Internal Resistance Approx 11.0 mΩ
Portable apparatus, lights and
Discharge : -15 50℃ (5 122℉)
instruments;
Operating Temp.Range Charge : 0 40℃ (32 104℉)
Electric toys
Storage : -15 40℃ (5 104℉)
Illumination light
Nominal Operating Temp. Range 25 3℃ (77 5℉ )
Fire alarms
Portable power Initial Charging Current less than 9.9 A.Voltage
Cycle Use
Wheelchairs 14.4V~15.0V at 25℃(77℉)Temp. Coefficient -30mV/℃
Medical equipments. No limit on Initial Charging Current Voltage
Standby Use
13.5V~13.8V at 25℃(77℉)Temp. Coefficient -20mV/℃
40℃ (104 ℉) 103%
Capacity affected by
ISO ISO OHSAS Temperature
25℃ ( 77 ℉ ) 100%
86%
9001 14001 18001 0℃ ( 32 ℉ )
KUHN GD series batteries may be stored for up to 6 months
Self Discharge at 25℃(77℉) and then a freshening charge is required.
For higher temperatures the time interval will be shorter.
Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values.
GD33-12 12V33AH
GD SERIES-Deep Cycle Battery
Dimensions
T5 Terminal
Unit: mm [inches]
]
17 [0.669] 79
.0
[R0
R2
130 2
180 2
155 2
49 2
5]
2]
31
0.0
3 [0.118]
0.
[R
.5
R0
[
8
% (A) (V/cell) Charge At 0.1C Amp initial charging current and 2.45V/Cell Constant
Voltage at 25 oC
120 6.0
Terminal Voltage(V)
12.0
Charged Volume
100 0.1C 2.5
5.5 11.0
0C 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
0 4 8 12 16 20 24 28 min H
Temperature Effects in Relation to Battery Capacity Cycle Life in Relation to Depth of Discharge
T e st i ng co nd it i on
D is ch ar gi ng :c ur r en t 0 .1 7C (F V 1 . 7V /c el l );
C ha rg in g: cu rr en t 2 .4 5V /c el l , ma x. 0. 25 CA ;
C ha rg in g v o lu me :1 25 % o f di s c ha rg ed ca pa ci t y .
120
120
0.1CA
100 0.12CA
0.21CA 100
80 1CA 80
Capacity (%)
2CA
Capcity(%)
60 3CA 60
100% 50% 30%
DOD DOD DOD
40
40
20
20
0 0
-20 -10 0 10 20 30 40 50
0 200 400 600 800 1000 1200 1400 1600 1800
Storage Time(Months)
KUHN GD BATTERIES
2
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/
specification are subject to modification without notice. Contact KUHN for the latest information.
www.kuhn.cl Page 2 of 2