Beruflich Dokumente
Kultur Dokumente
2. Mainframe System
NONE
3. OPEN System
HDS Confidential 1 of 9
2 Drive blockade and no progress of reboot on SVP
Phenomena Drives was blocked during the time between the completions of SCHIP
micro-program exchange download processing and reboot initiation, and
the reboot processing status displayed on SVP did not make a progress.
SSB=DFxx, and EFxx.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when HDD failures occur during the time between
the completions of SCHIP micro-program exchange download and reboot
initiation and then a drive is blocked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-15-00/00
Category HDD
Changed Part DKCMAIN
HDS Confidential 2 of 9
5 Micro-program update failure in configuration without DKA
Phenomena At micro-program upgrade in a configuration without DKA, if DKAF
was also checked on Micro-program Exchange dialog box and the
upgrading was executed, the operation itself was completed normally, but
[MP Ver. (Curt./FM)] on Version window of SVP Maintenance window
showed abnormality. All the information on [MP Ver. (Curt./FM)] was in
red. Besides, * (asterisk) was added to the end of version of DKAF.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Configuration without DKA
(2) On Micro-program Exchange dialog box, DKAF is checked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
SVP: All
Fixed Product/Version DKCMAIN: 70-02-15-00/00
SVP: 70-02-10/00
Category Open and Mainframe
Changed Part DKCMAIN, SVP
HDS Confidential 3 of 9
8 I/O processing stop with SSB=B801 output at pair deletion
Phenomena When a UR pair using LUSE volumes was deleted during I/O processing,
the I/O processing stopped and SSB=B801 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open
(2) There is a UR pair using an LDEV used for LUSE.
(3) An I/O is executed.
(4) The UR pair is deleted.
Causes and Updates The micro-program has been modified to display correct numbers.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-15-00/00
Category Universal Replicator
Changed Part DKCMAIN
HDS Confidential 4 of 9
11 ALARM lamp and SIM output at MP PCB failure
Phenomena During dump collection, when an MP PCB failure occurred, ALARM
lamp lighted up and SIM=3073xy (Processor blockage EC=32FE) was
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Dump is being collected.
(2) A error in communication between SVP and DKC occurs
(SSB=391F).
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-15-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 5 of 9
14 DRR blockage with SSBs output during LDEV format
Phenomena During LDEV format, multiple DRRs were blocked and SSBs=7B48,
7B58, and B2CB were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) The number of CUs that can be mounted (64 CUs/255CUs) is set to
255.
(2) LDEV format of Mainframe VOL is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-15-00/00
Category Mainframe
Changed Part DKCMAIN
HDS Confidential 6 of 9
17 Frequent SSB=6D79 and host message output after switching to
Hyper PAV
Phenomena When the PAV mode was switched to Hyper PAV on a host, SSB=6D79
and host message IOS071I (START PENDING) might frequently be
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe host connection
(2) One of the following operations is executed during I/O processing.
(a) The host PAV mode is switched to Hyper PAV while the Hyper PAV
license is already installed.
(b) While the host PAV mode is Hyper PAV, the Hyper PAV license is
installed.
(c) After the PAV license expires while the host PAV mode is Hyper
PAV and the Hyper PAV and PAV licenses are already installed, the
PAV license is installed again.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-15-00/00
Category Mainframe
Changed Part DKCMAIN
HDS Confidential 7 of 9
19 Temporary link down or continuous ICC occurrence
Phenomena After HTP micro-program exchange, temporary link down occurred or
ICC continuously occurred with the following output.
SSB=1601, 1602, 7A20 (Err_Code: 26A0, 708C, 1870)
HTP=26A0, 708C, 1870
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) FICON is used.
(2) An MPB is installed while HPF (Compatible High Performance
Connectivity for FICON) is installed. After that, PS OFF and ON, or
replacement of CMF PCB with which a host path is connected is not
performed.
(3) Online HTP micro-program exchange is performed.
(4) The host issues an HPF command to DKC.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version HTP: All
Fixed Product/Version HTP: 70-02-08
Category Mainframe
Changed Part HTP
HDS Confidential 8 of 9
22 Update of SSD micro-program
Phenomena "02/0480" error was reported from the SSDs indicating a failure of Power
Back part inside the SSD.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The phenomenon occurs on both SDT2A-S and SDT5A-S with SSD
micro-program Rev.00-00-48.
Causes and Updates The SSD micro-program has been modified to fix the unexpected
02/0480 error reporting.
Affected Products/Version SDT2A-S/SDT5A-S: 00-00-48
Fixed Product/Version SDT2A-S/SDT5A-S: 00-00-4F
Category Open or Mainframe
Changed Part SSD
HDS Confidential 9 of 9