www.wavecontrol-rfsafety.com Subject to Change
The effect of Electromagnetic Radiation on the general public is becoming a
concern as the number of sources increases. Recent legislation limiting the
maximum levels of electromagnetic radiation permitted from these
installations has been introduced to protect the public, but compliance testing
is often performed infrequently and then over a short period of time.
The monitoring stations continuously sample the electromagnetic field (24h/365d), store
the readings and transmit them regularly to the Control Center.
The electromagnetic field is measured by means of triaxial isotropic probes that allow a
composite reading of the field in full as it arrives from all spatial directions.
The computerized control system is designed for direct integration via the Internet, allowing
authorized users to track the monitoring stations from anywhere with an Internet connection. In
addition, the collected data can be published to make it available for consultation by any
interested person.
RADIATION
EMITTER
Control Center
MonitEM
2/7
www.wavecontrol-rfsafety.com Subject to Change
APPLICATIONS
MonitEM is an ideal system for those
responsible for base station reliability and
performance. Continuous verification that
the electromagnetic radiation produced by
the base stations, telecommunication
facilities and power lines is below
recommended international limits maintains
public confidence.
3/7
www.wavecontrol-rfsafety.com Subject to Change
CONTROL CENTER
The data capture results are transmitted to
the Control Center, which is configured for
remote management of Measurement
Stations. From the Control Center the station
identification parameters, alarm systems,
data storage, data transmission, report
generation, etc., can all be programmed, and
it can be used to provide access via the
Internet to the information generated.
ALARM SYSTEM
MonitEM can be programmed to provide an alarm signal if the recorded level of
electromagnetic radiation exceed set levels. The Control Center can then alert the user when
this event occurs.
The Control Center receives this alarm warning and shows in real time which remote
monitoring station is measuring field levels above the programmed threshold.
4/7
www.wavecontrol-rfsafety.com Subject to Change
CALIBRATION
MonitEM stations are individually calibrated before delivery, a necessary prerequisite for
reliable and professional measurement. An uncalibrated device can give such a large error as
to make the measurement wholly unreliable.
5/7
www.wavecontrol-rfsafety.com Subject to Change
MONITORING STATIONS
Sensor Type Isotropic, RMS
Simultaneous measurement along the three axes
Probes system Interchangeable, automatic recognition
Sampling rate 500 ms
Average Sliding window. Averaging over 6 minutes
Data storage period Online mode: 30 or 60 minutes
Offline mode: 1, 2, 4, 5, 6, 10, 15, 20, 30, 60 minutes
Programmable alarm Field level, low battery, hibernation, opening, calibration,
communication error
Working mode Online / Offline
Communication with Control Center GPRS/3G (online mode)
Communication with PC USB 2.0
Local data download USB 2.0 (Offline mode)
Update USB, Micro SD or GPRS/3G
Memory Micro SD + Eeprom
Storage capacity According to micro SD
Temperature recorder Yes
Position recorder HSGPS (High Sensitivity GPS) device integrated (optional)
Active antenna
Installation Wall-mounted, mast-mounted or platform-mounted
Rejection of own fields The field generated by its own modem is rejected
Solar Autonomy >10 days with GPS off
>10 hours with GPS on
Power Supply 220V, solar, SAI, hybrid (smart energy)
Working temperature range -20ºC a +80ºC
Environmental protection IP65
Watchdog Independent. Integrated into smart-energy
Weight 3.6 kg (including solar panel)
Dimensions 253 mm x 292 mm x 385 mm
6/7
www.wavecontrol-rfsafety.com Subject to Change
CONTROL CENTER
Data download Configurable by user
Communication with GPRS/3G
measurement stations
Control Center Directly on the server or through the Internet
Management
Functions Seven levels of user and privileges
Operating scenarios: global mode, zones and sub-zones
Separate management of the measurement site and measurement equipment
Site information: active/inactive site, public site, address information, GPS
position, associated images, etc
Station information: name, alarm level, data storage period, calibration date,
download data period
Data visualization:
• Graphic and table
• Average, maximum and minimum
• Selection of interval Initial Date/Time – Final Date/Time
• Field limit values can be entered to filter results
Measurement sites displayed on a GIS (Graphic information system)
Automatic reports sent by email:
• PDF and CSV format
• List reports
• Short / Extended reports (diagrams and tables)
Alarms Programmable: field level, low battery, hibernation, door opening, calibration,
communication error
Software Created using open source software
Gmap features
Data display Public. Via Internet
General information Client's logo, language selection, general description
Map information Active sites, inactive sites, SMP measurements
Map display Map, image or hybrid
Site data Name, description, GPS position, measurement period and pictures of the site
Measurements Frequencies of measured data
information Maximum and average level
Standard limit
Graphic with the measured data related to the standard limit
7/7