Sie sind auf Seite 1von 39

transBio-Filter

Waste Water Treatment


Technology
Company Profile
• A venture of the Shroff group of companies.
• Excel Industries Ltd., Transpek Industry Ltd, Excel Crop Care Ltd., and
others.

• Our group also runs an NGO Shroff Foundation Trust with special focus
on farmer’s & rural community.

• Focused on providing Innovative and Efficient products and services to


improve agriculture & environment.

• Our products are transBio-filter- A Waste Water Treatment


Technology, Soil Testing Kit, Water Testing Kit, Bio-pesticides, Nutrient
Foliar Sprays, Mobile & Stationary Labs,
About transBio-Filter
transBio-Filter Process Flow
Sewage Waste
Water

Earthworm, Processed
Bio- Compost
organic Media & transBio-Filter (To be harvested once in a
Selected Microbial System year)
Culture

Treated Water rich in


Nutrients & Oxygen

After Tertiary
Treatment (Use in
River Discharge
Flushing & Washing
Use in Agriculture
applications)
Accreditation of transBio-filter Technology

• Clearances from Pollution Control Boards like Gujarat Pollution Board,


Maharashtra Pollution control Board, Punjab Pollution Control Board, Delhi
Pollution Control Board.
• Patent Applied No. 201621036616.
• Validation by ATIRA (Ahmedabad Textile Industry’s Research Association).
• Technology Performance Report certified by Griffith University, Australia
• Award Received in Best Water Treatment Technology in India through
ASSOCHAM 2017 and for “Environment abatement and Pollution control”
in the year 2015 by Federation of Gujarat Industries.

50+ Biofilter plants installed spread across India in 11 states running successfully
5
Segments
transBio-Filter technology is successful in following segments:
1.Domestic Sewage & Municipal waste water
▪ Residential Complexes & Housing schemes
▪ Commercial establishments
▪ Institutes (Schools, college & Universities)
▪ Resorts & Hotels
▪ Religious places etc.

2.Chemical & Pharmaceutical Industries


3.Block / Dye Printing
4.Sugar Industries
5.Dairy Industry
6.Food Processing Units
7.Fisheries Industries
transBio-Filter Plants Modular & Civil Constructed
Capacity range 3KLD to 1.2MLD
List of transBio-filter Technology Successfully
Installed
Type of waste
Sr. No Name & Location Capacity
water
Excel Crop Care Ltd, Bhavnagar,
1 Sewage 1 .2 MLD
Gujarat
Transpek Industry Ltd, Vadodara, Sewage+
2 55KLD & 75 KLD
Gujarat Industrial
3 Agrocel Industries Ltd, Kutch, Gujarat Sewage 25 KLD
4 Sam Fine O Chem, Rajkot, Gujarat Sewage 10 KLD
Gharda Institute of Technology,
5 Sewage 30 KLD
Chiplun, Maharashtra
6 Raipura Village, Vadodara, Gujarat Sewage 2 KLD
A L N Rao Medical College,Koppa,
7 Sewage 20 KLD
Karnataka
8 Shiva Pharma Chem Ltd, Vadodara, Sewage 10 KLD
Chemical System Technologies, New
9 Sewage 80 KLD
Delhi
Rajda Industries & Exports Pvt Ltd,
10 Sewage 10 KLD
Kolkata 8/18/2017

11 VRTI, Mandvi Kutch Dyes 28 KLD


List of transBio-filter Technology Successfully
Installed
Type of
Sr.
Name & Location waste Capacity
No
water
12 ACC Cement Limited. Bellary, Karnataka Sewage 20 KLD
13 ACC Cement Limited ,Bargarh,Orissa Sewage 10 KLD
14 ACC Cement Limited ,Jamul, Chattisgarh Sewage 5 KLD
15 ACC Cement Limited ,Jamul, Chattisgarh Sewage 10 KLD
Marathwada Auto Pvt Ltd,Aurangabad
16 Sewage 10 KLD
,Maharashtra
17 Ecoware ,Uttar Pradesh Sewage 10 KLD
18 VIVEC, Paldi, Gujarat Sewage 40KLD
19 Best Value , Karakhadi , Gujarat Sewage 10KLD
20 Best Value , Karakhadi , Gujarat Sewage 10KLD
21 Oasis Valleys, Chanod, Gujarat Sewage 35KLD
Transpek Silox Industry Ltd, Vadodara,
22 Sewage
Gujarat 35KLD
Viswaat Chemicals Ltd, Ambernath, 8/18/2017
23 Sewage 109 KLD
Maharashtra
List of transBio-filter Technology Successfully
Installed
Sr.
Name & Location Type of waste water Capacity
No
Axalta Coating Systems India Pvt Ltd,
24 Sewage 10KLD
Vadodara, Gujarat
Axalta Coating Systems India Pvt Ltd,
25 Sewage 10KLD
Vadodara, Gujarat
26 Ionex, Mumbai, Maharashtra Sewage 5KLD
27 B B Dairy, Savli, Gujarat Dairy Effluent 25 KLD
Dyeing & Printing
28 Khamir, Ajrakhpur, Gujarat
Effluent 50 KLD
Avani Food Products, Mehasana,
29 Casein Base
Gujarat 6 KLD
30 Sam Resorts, Bengaluru, Karnataka Sewage 3 KLD
31 Sam Resorts, Bengaluru, Karnataka Sewage 3 KLD
32 KVK , Jalana , Maharashtra Sewage 100 KLD
AWPL at Hotel Surya Kaiser Palace,
33 Sewage 20 KLD
Varanasi , Uttar Pradesh
Rann of Resort , Dhordo, Kutch ,
34 Sewage 10 KLD
Gujarat
35 AWPL at GNDEC, Ludhiana, Punjab Sewage 500 KLD
10
List of transBio-filter Technology Successfully
Installed
Sr. Type of
Name & Location Capacity
No waste water
36 Bansal Roofing, Vadodara , Gujarat Sewage 3 KLD
37 Indo Green , Pune, Maharashtra Sewage 10 KLD
38 Ram Krishna Ashram,Gwalior, MP Sewage 10 KLD
39 Merino Industries, Hosur Sewage 10 KLD
Transmetal Ltd Karakhadi, Vadodara, Chemical
40 50 KLD
Gujarat Waste
41 ITI Mahuvad, Gujarat Sewage 20 KLD
42 Ekalbara School, Vadodara, Gujarat Sewage 3 KLD
43 Solaris Chemtech Industries limited, Bhuj Sewage 3 KLD
44 Agrocel Industries Ltd., Awania Sewage KLD
45 Excel Industries, Rajkot Sewage 3 KLD
Excel Industries, Rajkot Municipal
46 Sewage
corporation 3 KLD
11
47 Yeshree Auto comp, Aurangabad Sewage 10 KLD
Success Stories
SEWAGE WASTE WATER TREATMENT

8/18/2017
transBio-Filter- 1.0 MLD at Bhavnagar
(City sewage treated and recycled for Industrial & Gardening use)

Sewage nala Pumping station transBio-Filter Inner view

Raw & Treated water Quality


Reuse of treated water

13
Average Results Obtained
(1.2MLD STP Bhavnagar)
After
Before Standard Norms
Parameters transBio-Filter
Treatment for Land Irrigation
Treatment
pH 7.0-7.8 7.0 – 7.5 5.5-9.0
TDS (ppm) 1500-2000 < 200 2100
Turbidity (NTU) 100-150 Nil
COD (ppm) 200-400 < 20 100
BOD (ppm) 100-200 <5 30
DO (ppm) Nil 2-3
Colour Dark Grey Clear White
Odour Strong Odourless
Fecal Coliforms 6 3
(MPN/100ml) > 10 < 100 < 10
transBio-Filter- 100 KLD at Krishi Vigyan Kendra, Jalna
( City sewage treated and recycled for Agriculture)
transBio-Filter Plant
Intake from city Sewage nala

Treated water for Agriculture use Plant Running on Solar Panels

Growth in summer
transBio-Filter at Keshopur,Delhi Jal Board
“Toilet to Tap’’

Type of Waste Water Domestic City Sewage


Capacity of transBio-Filter Plant 80 KLD
INDUSTRIAL WASTE WATER

8/18/2017
What Industries seek in wastewater management ?

• Maximum reduction in the effluent quantity generation.


• Environmental compliance.
• Generation of reusable water, if possible also revenue
generation.
• Minimum CAPEX & OPEX
• Minimum Footprint
SETTING UP ETP !!
WHAT EXPERT’S NEED TO LOOK INTO - SELECTION CRITERIA

▪ Life cycle cost


This includes installation costs and operation costs, which are usually capitalized over
the life of the project to provide a common basis for comparing different options.
▪ Cost-effectiveness
Expressed as a unit cost to provide a basis for comparing different options (Rs./m3). For
example, economies of scale often reduce the unit cost of treating wastewater but are
not necessarily cost-effective if wastewater flows are not high enough to allow the
technology to perform optimally.
▪ Reliability
Measure of how well a system performs in relation to expectations without breakdowns
or failure to treat wastewater to meet water quality objectives. Reliability also is
associated with simplicity of operation and ease of maintenance. Reliable systems that
require highly skilled operators and careful maintenance would be less appropriate.
▪ Simplicity
Simplicity of operation and ease of maintenance. This is highly desirable for ETP’s
designed for SMEs.
▪ Performance
Measured in terms of percent removal or may be expressed as typical treated effluent
concentrations required to meet water quality objectives

▪ Ability to meet water quality objectives


A primary screening criterion. Any system that is not able to meet water quality objectives
does not need to be considered any further.

▪ Adaptability to change in influent quality


This is a very important criterion for ETPs designed for SMEs because wastewater quality tends
to be more variable than for conventional municipal wastewater treatment.

▪ Adaptability to varying flow rate.


This is an important criterion for CETPs designed for SMEs, if the industries involved have highly
varying flow rates.
SUCCESS STORIES
DAIRY & DAIRY PRODUCTS WASTE
WATER
M/s. B.B.Dairy, Savli Unit, Vadodara
Type of Waste Water Dairy waste water
Capacity of Biofilter Plant 25 KLD Plant

Before
Parameters After Treatment
Treatment
pH 5.5 – 6.5 7.50 - 7.90

Turbidity (NTU) 350 - 1000 10 - 25

COD (ppm) 2500 - 3500 150 - 200


BOD (ppm) 1500 - 2000 80 – 100
DO (ppm) Nil 2-3

Colour White Turbid Pale Yellow

Sour
Odour Odourless
Fermented
NH4-N (ppm) 25 - 30 10 - 15
NO3-N (ppm) Nil 15 - 20

94 % reduction in COD
M/s. Srinivasa Dairy, Hyderabad
Type of Waste Water IceCream manufacturing Wastewater
Capacity of transBio-filter Plant Pilot Plant Study
Source of Waste Water Paneer Whey
Onsite Pilot trials
Parameters Input water Output water
pH 4.0-4.5 8.0 – 8.5
TDS (ppm) 7500-8000 3000-3200
Turbidity
(NTU)
> 1000 15-20
COD (ppm) 52000-62000 220-250
BOD (ppm) 48000-55000 100- 120
Pale yellow with
Colour Pale Yellow
mild green tinge
Odour Strong Odourless
Oil & Grease
500-550 15-20
(ppm)
Ammonical –N
15-20 < 10
(ppm) 23

99 % reduction in COD
CHEMICAL & DYE INDUSTRIES WASTE
WATER

8/18/201
CASE STUDY I - Chemical waste water treatment
with transBiofilter
Type of Waste Chemical Waste Before After
Water Water Parameters
Treatment Treatment
Capacity of
180 KLD pH 8.0 - 9.0 7.0 – 8.0
Biofilter Plant
TDS (ppm) 12500 10500
Turbidity (NTU) 80-100 < 5.0
Sulphide (ppm) 30-40 Nil
COD (ppm) 500 80-100
BOD (ppm) 150 30-50
DO (ppm) Nil 1.5 – 2.0
NH4-N (ppm) 20 - 25 < 10.0
NO3-N (ppm) 10 - 15 25 - 30
Colour White Turbid Colourless

Inlet Outlet Odour Strong Odourless

80 – 85 % reduction in COD
Replacing Conventional ETP with Biofilter
• Conventional ETP • transBio-Filter Plant
(Activated Sludge Process)

Area: 3,000 square meters Area: 400 square meters


Comparison between
Conventional ETP v/s Biofilter

Sr. Existing Bio-Filter %


Details
No: ETP plant Plant Reduction
Total Effluent
1. Treated 180 180 N.A.
(M3/Day)
3000 Sq. 400 Sq.
2. Area Covered 86 %
Mtr Mtr
Number Of
3. 12 Nil 100%
Aerators
Comparison between
Conventional ETP v/s Biofilter

transBio- %
Sr. Existing
Details Filter Reductio
No: ETP plant
Plant n
Power Load
4. 110 HP 20 HP 82%
(HP)
5. Retention Time 10 Days 45 mins 99%
6. CAPEX 200 Lac. 50 Lac. 75%
181 63
7. OPEX 65%
Rs./KL Rs./KL
Savings of INR 77.52 Lakhs per year
PILOT STUDY I – DETC Effluent wastewater
treatment with transBiofilter
Type of Waste DETC Effluent Before After
Water Waste Water Parameters
Capacity of Treatment Treatment
110 KLD
Biofilter Plant pH 6.5 to 6.7 6.8 to 6.9
TDS (ppm) 28000 16000
Turbidity (NTU) 500 30
Sulfide (ppm) 300 Nil
COD (ppm) 16000 2200
Colour Yellow Pale Yellow
Strong
Odour Mild
Sulphide like

Inlet Outlet 86.25% reduction in COD


PILOT STUDY II – Sulphur wash Effluent
wastewater treatment with transBiofilter
Type of Waste DETC Effluent Before After
Water Waste Water Parameters
Capacity of Treatment Treatment
160 KLD
Biofilter Plant pH 8.9 6.8
TDS (ppm) 110360 46420
Turbidity (NTU) 750 13
Sulfide (ppm) 740 Nil
COD (ppm) 23000 1229
Colour Greyish Light yellow

Odour Sulphide like Mild

Inlet Outlet 89 % reduction in COD


PILOT STUDY III – Caprolactam Effluent
wastewater treatment with transBiofilter
Type of Waste Caprolactam Effluent Before After
Water Waste Water Parameters
Treatment Treatment
Capacity of
80 KLD pH 1.9 7.1
Biofilter Plant
TDS (ppm) 47820 15000
Turbidity (NTU) 6 55
Sulfide (ppm) 39 Nil
COD (ppm) 52416 5634
Ammonia (ppm) 3332 950
Sulfites (ppm) 105 10
Colour Brownish Red Pale Yellow
Mild Ammonia
Odour Odourless
like
Inlet Outlet
89.25% reduction in COD
PILOT STUDY IV – MEE SLOP Condensate Effluent
wastewater treatment with transBiofilter
Type of Waste MEE SLOP Condensate Before After
Water Waste Water Parameters
Treatment Treatment
Capacity of
400 KLD pH 8.9 7.7 to 8.0
Biofilter Plant
TDS (ppm) 3035 3000
Turbidity (NTU) 25 20 – 25
Sulfide (ppm) 169 Nil
COD (ppm) 4900 250
BOD (ppm) 3400 55
Ammonia (ppm) 1250 50
Colour Brown Pale yellow

Odour Alcoholic Odourless


Inlet Outlet
94.89% reduction in COD
PILOT STUDY V – CTRO wastewater treatment
with transBiofilter
Type of Waste
CTRO Waste Water Before After
Water Parameters
Treatment Treatment
Capacity of
150 KLD pH 4.3 7.2 to 8.0
Biofilter Plant
TDS (ppm) 366 3050
Turbidity (NTU) 20 20 – 30
Sulfite (ppm) 52 Nil
COD (ppm) 5800 250
BOD (ppm) 2000 50
Ammonia (ppm) Nil Nil
Colour White Turbid Pale yellow

Odour Solvent Type Odourless


Inlet Outlet
95.68% reduction in COD
PILOT STUDY VI – Sodium Formate based
wastewater treatment with transBiofilter
Type of Waste Sodum formate based Before After
Parameters
Water effluent Treatment Treatment
Capacity of
30 KLD pH 6.5 6.8
Biofilter Plant
TDS (ppm) 17400 < 500
Turbidity (NTU) 300 <5
Sulfide (ppm) 155 Nil
COD (ppm) 24800 < 100
So3 (ppm) 388 Nil
Colour Reddish Brown Colourless

Odour Formate mild

Inlet Outlet
99% reduction in COD
Phenolic wastewater treatment with transBiofilter
Type of 4,2
Waste BromoChloro Sr. Parameters Inlet Outlet after After
Water Phenol no. transBio- Advanced
Capacity
of Filter™ Oxidation
6KLD System System
Biofilter
Plant Treatment
1 pH 3.8 6.9 7.2
2 TDS (ppm) 18880 8200 7900
3 Turbidity (NTU) 3.3 5.0 5.0
4 Colour Colourless Pale Yellow Very Light
5 Odour Phenolic Odourless Odourless
6 COD (ppm) 4605 600-700 624
7 BOD (ppm) 1650 150 220
8 Sulfide (ppm) 933 Nil ---
9 Sulfates (ppm) 769 25 ---
10 Phenol (ppm) 1325 3-4 < 1.0
11 Chlorides (ppm) 4870 1700 ---
8/18/2017

76% reduction in COD


PILOT STUDY VII – Natural Dye Industry based
wastewater treatment with transBiofilter
Type of Waste Natural Dye Industry Before After
Parameters
Water based effluent Treatment Treatment
Capacity of
50 KLD pH 7.5 to 8.0 8.0 to 8.5
Biofilter Plant
Turbidity (NTU) 200 to 400 < 10
DO (ppm) Nil 3 to 4
COD (ppm) 1500 < 150
BOD (ppm) 500 < 30
Colour Reddish Blue Pale Yellow

Odour Muddy Odourless

Inlet Outlet
90% reduction in COD
Key Features

Lowest Capital No skilled labour Lowest Power


and Operations required consumption
cost

Surety of getting Meets pollution control Lowest area


consistent, sustainable Board norms requirement
and reliable results
Organic Waste Converter (OWC)
Organic Waste fed to
OWC along with
Bioculum and
absorbent after
Segregation

Removal of raw
compost after 15 min.
Cycle.

Raw compost kept in


curing system
THANK YOU !

Transchem Agritech Pvt. Ltd.,


850/2, GIDC Estate,
Makarpura,
Vadodara – 390 010, Gujarat,
Ramanand Jha (GM – Marketing) India
Mobile No : +91 9873624396, 8511197785 Tel : 0265-6542246/6544069
Email Id : ramanand@transchem.in www.transchem.in

Das könnte Ihnen auch gefallen