Beruflich Dokumente
Kultur Dokumente
com
:2008 CER
01
0
TIF
ISO 9
IED
We work with a variety of industries including utility, telecom, data centers, industrial, government &
defense, motive power & other applications where backup battery performance is critical.
Battery Chargers
Energenius IQ Microprocessor Battery Charger and Monitoring System 42
AT 10.1/AT30 Microprocessor Controlled Float Battery Chargers 43
MP-1000 Modular High Frequency Motive Power Battery Charger 44
GC-1000 Golf Cart Battery Charger 45
Gas Detection
GD-Series Gas Detectors 46
VS-Series Ventilation Systems 47
YE UNIVE
EE
ITY
eeu
MIL
IN
AU
NS
CO Increasing Critical Power Reliability with Hands-on Education
W
KEE
WIS
4 5
To Order Call Toll Free:
1-877-805-3377
Product Description
The BQMS Battery Monitoring System is designed to measure the aging status
of up to 480 cells/units by measuring and recording: string voltage, string current,
cell/unit voltage, internal resistance, cell/unit temperature and ambient temperature.
The BQMS is intended for use on vented lead acid (VLA), valve regulated lead acid
(VRLA), and nickel-cadmium (Ni-Cad) battery systems. Installation of the BQMS is
non-intrusive and can be completed while the battery system is online.
Product Advantages
• 24/7/365 Battery Monitoring.
• Comprehensive Battery Management Software.
• Installation while systems are online.
Battery Monitoring Systems
Modules
Connected in daisy chain and
mounted on the battery rack. Wired BMS/SCADA Server Client
directly to the battery connections
for measurement of cell/unit
parameters.
Connection Clamps
Physical connection to battery
system. Installs to battery inter-cell
cables or busbars.
SMS/Email
BMS-SERIES
Server & Client PC Clamp Connections to Battery Bank
Main computer which interfaces with
the CCU. Runs Centroid Snet Server
application. Client PC’s installed on
same network for additional users.
Technical Specifications
Ordering Information
No. Model # Description
Product Description
The iPQMS Battery Monitoring System is designed to measure the aging
status of up to 448 cells/units by measuring and recording: string voltage, string
current, cell/unit voltage, internal resistance, and temperature. The iPQMS is
intended for use on vented lead acid (VLA), valve regulated lead acid (VRLA),
and nickel-cadmium (Ni-Cad) battery systems. Installation of the iPQMS is non-
intrusive and can be completed while the battery system is online.
Product Advantages
• 24/7/365 Battery Monitoring.
• Comprehensive Battery Management
Battery Monitoring Systems
Software.
• Installation while systems are online.
• Meets IEEE and NERC standard
recommendations for battery monitoring.
• Patented ripple-removing algorithm to
filter out noise from measurements.
• Injects minimal current for measurement.
• Simple to install with custom, pre-
assembled installation materials.
• Can be powered by AC or DC. iPQMS Installation on 125VDC Utility Battery System
Connection Clamps
Physical connection to battery
system. Installs to battery inter-cell
cables or busbars.
SMS/Email
BMS-SERIES
Server & Client PC Clamp Connections to Battery Bank
Main computer which interfaces
with the MPU. Runs Centroid Snet
Server application. Client PC’s
installed on same network for
additional users.
Ordering Information
No. Model # Description
Product Description
The BDS-Pro Battery Monitoring System is designed to measure the aging
status of up to 24 cells/units by measuring and recording: string voltage, string
current, cell/unit voltage, internal resistance, and temperature. The BDS-Pro is
intended for use on vented lead acid, valve regulated lead acid, and nickel-cad-
mium battery systems. The included Centroid 2 Battery Management Software
records measured data for comprehensive trending analysis. The BDS-Pro
Battery Monitoring Solution is an accurate, user-friendly and economic solution
for monitoring systems using up to 24 cells/units.
Product Advantages
Battery Monitoring Systems
Server PC
Main computer which interfaces
with the MPU. Runs Centroid
Snet Server application.
BMS-SERIES
Client PC
Additional computers on the Clamp Connections to Battery Bank SMS/Email
network which communicate with
the Server PC. Runs Centroid
Viewer application.
Technical Specifications
Ordering Information
No. Model # Description
Product Description
The BMS-icom Battery Monitoring System is designed to measure the
aging status of up to (4) 12V units by measuring and recording: string voltage,
string current, unit voltage, internal resistance, and temperature. The included
Centroid 2 Battery Management Software displays and records measured
data for comprehensive trending analysis. The BMS-icom is accurate,
repeatable, user-friendly, and cost effective solution for monitoring 48VDC
systems using (4) 12V batteries.
BMS-icom
Product Advantages
• 24/7/365 Battery Monitoring
• Installation and maintenance can be done while battery
systems are online
• Meets IEEE and NERC standard recommendations for
Battery Monitoring Systems
battery monitoring
• Utilizes a patented ripple-removing algorithm
• Injects minimal current for measurement
• Simple to install with custom, pre-assembled materials
• Designed for 48V systems (12V cells)
• Alerts in real-time during outbreak
BMS-icom Installation
Technical Specifications
Battery Capacity: 5 – 6,000 Ah
Nominal Cell/Unit Voltage: 12V
Measurement Range:
String Voltage: 0 – 150 VDC
String Current: ±999.9 A
System Includes
String Voltage / Current: ±0.5% / ±1% • BMS-icom hardware
Temperature: ±2% • Centroid 2 battery
Accuracy:
Internal Resistance: ±2% management software
Cell/Unit Voltage: ±1% • All installation materials
Test Speed / Test Load: 4 seconds per cell / less than 2 A per cell/unit • Fitted CT clamp
• USB drive with software
Measuring Interval: Adjustable from 10 min to 24 hours (voltage & resistance) and support literature
Temperature: 0 – 65 °C (32 – 150 °F) • Optional: Spare parts kit
Operating Environment:
Relative Humidity: Under 80%
Input: 38 – 58 VDC (from connected batteries)
Power Requirements:
Consumption: 7 W
Dimensions / Weight: 140 x 121 x 44.5 mm (5.5 x 4.8 x 1.8 in)
Ordering Information
No. Model # Description
1 BMS-icom Battery Monitoring Solutions: Up to 4 (12V) Jars/Cells
VGM-SERIES
Features
• Color touchscreen simple interface
• Ethernet connectivity to web interface, (4) Form C Contacts
• High reliability & durability
• Simple installation
• Includes mounting kit for DIN rail or wall mount
Alarm Contacts
• VGM-100 - (1) Form C each for over voltage, under voltage,
positive ground, & negative ground
• VM-100 - (2) Form C each for over & under voltage
• GFM-100 - (2) Form C each for positive & negative ground
Web-Interface for Monitoring
Technical Specifications
VGM-100/VM-100: 18-32, 38-60, 90-160, 180-320 VDC
Measurement Range:
GFM-100: 20-28, 38-56, 90-155 VDC
Fault Resistance Limit Set: 1 – 100 kOhm
Kit Includes
Output Contacts: (4) Form C
125 VAC/VDC: 0.5A • VGM-Series monitor
Contact Rating:
30VDC: 2A
• DIN rail mounting clip
Maximum Switching Power: 60 W • Backplate for wall
Power requirements: Powered by connected battery DC voltage mounting
Noise Immunity: IEEE/ANSI Standard C 37.90a-1989 compliance
Time Delay to Alarm: Adjustable 1 – 999 seconds
Operating Environment: Temp: 0 – 55°C (32 – 131°F), Humidity: 0 – 95% RH
Dimensions / Weight: 147 x 91 x 45 mm (5.77 x 3.56 x 1.77 in) / 284 g (10 oz)
Ordering Information
No. Model # Description
(1)
1 VGM-100-XXX Voltage & Ground Fault Monitor, available for 24V, 48V, 125V, or 250V
2 VM-100-XXX Voltage Monitor, available for 24V, 48V, 125V, or 250V
3 GFM-100-XXX Ground Fault Monitor, available for 24V, 48V, 125V, or 250V
1) Determine part number for required voltage, Ex. VGM-100-XXX would be VGM-100-125 for 125V applications.
Sensor Installation
Installation of the ELM sensors is simple and fast. Sensors
are daisy chained together via provided, pre-cut ribbon
cable. All required materials for installation are provided and
do not require modification. Each ELM sensor is installed
to front of the battery case via a peel off adhesive. Small
marks on the sensor allow it to be easily lined up with the
minimum line on the cell/unit for accurate level detection.
No marking of the battery jar is required during installation.
ELM-SERIES
Technical Specifications
Battery Types: Compatible with all transparent flooded battery types
35°C (95°F), ± 2°C (3.5°F)
Temperature Alarm 49°C (120°F), ± 2°C (3.5°F)
Activation: 63°C (145°F), ± 2°C (3.5°F) System Includes
Ordering Information
No. Model #(1) Description
1 ELM-4C Electrolyte Level Monitoring Solution: Up to 4 Cells/Units
2 ELM-6C Electrolyte Level Monitoring Solution: Up to 6 Cells/Units
3 ELM-8C Electrolyte Level Monitoring Solution: Up to 8 Cells/Units
4 ELM-12C Electrolyte Level Monitoring Solution: Up to 12 Cells/Units
5 ELM-24C Electrolyte Level Monitoring Solution: Up to 24 Cells/Units
6 ELM-60C Electrolyte Level Monitoring Solution: Up to 60 Cells/Units
7 ELM-120C Electrolyte Level Monitoring Solution: Up to 120 Cells/Units
8 ELM-240C Electrolyte Level Monitoring Solution: Up to 240 Cells/Units
1) Common configurations shown, custom configurations available.
The alarm relays are ‘fail-safe’, meaning the user will always get an
indication of supply failure. Several batteries in the vicinity of each
other may be connected in series to the same monitor. In the event
of one or more jars exceeding critical temperature, or a break in the
BTM-SERIES
sensor circuit, the monitor warning relay activates and the warning
LED on the monitor is illuminated. Also at the same time an LED
flashes on the sensor attached to the over-temperature battery jar,
BTM-Series Monitor & Sensor indicating the source of the fault. Should more than 4 jars exceed
critical temperature, the system critical alarm relay activates
Features
• Low cost monitor for thermal runaway
Battery Temperature Monitors
detection
• Monitors individual unit temperatures for
thermal runaway conditions
• Ensures compliance with US IFC608.3
• Simple fail-safe change-over relay alarm
interfaces (2)
• Bright LEDs pinpoint individual over-
temperature jars
• Fast one-wire acid and gas tight IDC
connections
• Sensor circuit break detection
• Alarm on power supply failure (fail-safe) Typical Connection of Sensors from Main Monitor
Technical Specifications
Alarm Range: Activation at 35°C (95°F), ± 3°C (5°F)
Reinstatement Temp: 2°C (3.5°F) below activation temperature LED Indicators for:
Input Voltage: DC 12V, 0.1A • 1+ Jars critical temperature
• 4+ Jars critical temperature
Output Relays (2) SPDT volt-free contact relays • Power failure
Monitor: 84 x 40 x 77 mm (3.3 x 1.6 x 3 in) • Sensor circuit break
Dimensions:
Sensor: 38 x 20 x 10 mm (1.5 x 0.8 x 0.4 in)
(L x W x D)
Cables: 300 mm (11.8 in)
Compliance: UL, CE
Ordering Information
No. Model # Description
1 BTM-Series (1)
Battery Temperature Monitor includes (1) monitor and number of sensors per jars / cells
1) Model number varies per number of jars (Ex. BTM-60C for system with 60 jars)
Meet Industry
Guidelines &
IEEE
Requirements
NERC
17
To Order Call Toll Free:
1-877-805-3377
alarming to ensure correct float voltage is being applied on the station No periodic verification of float voltage of
DC supply. battery charger is required.
• BQMS: Monitors String Voltage
Any battery based station DC supply with monitoring and alarming of
battery string continuity. No periodic verification of the battery continuity
• BQMS: Monitors String/Cell Voltage & Cell Internal/ is required.
Connection Resistance
Any battery based station DC supply with monitoring and alarming of
the intercell and/or terminal connection detail resistance of the entire No periodic verification of the intercell and
battery. terminal connection resistance is required.
• BQMS: Monitors Cell Internal & Connection Resistance
Any Valve Regulated Lead-Acid (VRLA) or Vented Lead-Acid (VLA)
station battery with internal ohmic value or float current monitoring and No periodic evaluation relative to baseline of
alarming, and evaluating present values relative to baseline internal battery cell/unit measurements indicative of
ohmic values for every cell/unit. battery performance is required to verify the
• BQMS: Monitors DC Current, & Internal Ohmic Values for all station battery can perform as manufactured.
Battery Types
Any Valve Regulated Lead-Acid (VRLA) or Vented Lead-Acid (VLA) No periodic inspection of the condition of all
station battery with monitoring and alarming of each cell/unit internal individual units by measuring battery cell/unit
ohmic value. internal ohmic values of a station VRLA or
• BQMS: Monitors Ohmic Value of Each Cell Vented Lead-Acid (VLA) battery is required.
Ordering Information
No. Model # Description
1 BQMS Modular Battery Monitoring Solution
Ordering Information
No. Model # Description
Compliance Solutions
1 ELM-Series (1)
Battery Electrolyte Level Monitor (1) monitor and number of sensors per jars / cells
1) Model number varies per number of jars (Ex. ELM-60C for system with 60 jars)
Ordering Information
No. Model # Description
1 GFM-100-XXX Ground Fault Monitor, available for 24V, 48V, 125V, or 250V
1) Determine part number for required voltage, Ex. GFM-100-XXX would be GFM-100-125 for 125V applications.
Ordering Information
Compliance Solutions
No. Model # Description
1 GFL-1000 Ground Fault Locator, Range: 24-1000V, 1-325 Hz
Ordering Information
No. Model # Description
SMART Constant Current DC Load Bank with Monitoring (12-480V, 100-600A)
1 SLB-Series* *See catalog page for complete model list
*Add “DAC” after model number for wireless monitoring per cell
IEEE 1491-2005 is for Selection and Use of Battery Monitoring Equipment in Stationary Applications.
MONTHLY INSPECTIONS
Maintenance Activities (Perform ALL items checked for your battery
VLA VRLA NiCd EEPS Solution
type)
X X Verify float voltage at the battery terminals IBEX-Series
Inspect general appearance and cleanliness of battery room or cabinet, racks, N/A Visual
X X X and batteries. Inspect for evidence of terminal, connector, and rack corrosion
X X X Verify charger output current and voltage IBEX-Series
ELM-Series /
X X Verify battery electrolyte levels SG-Series
BMS-Series /
X X X Verify ambient temperature and ventilation systems IBEX-Series
X Inspect for any unintentional battery grounds GFL-Series
X Record pilot cell’s voltage, specific gravity, and electrolyte level SG-Series
BMS-Series /
X X Inspect all installed battery monitoring systems are operational ELM-Series
QUARTERLY INSPECTIONS
Maintenance Activities
Maintenance Activities (Perform ALL items checked for your battery type
VLA VRLA NiCd EEPS Solution
in addition to monthly inspections)
BMS-Series /
X X X Verify voltage of each cell IBEX-Series
X Verify specific gravity of at minimum 10% of battery string cells SG-Series
Verify temperature of a representative sample of at minimum 10% of the BMS-Series /
X X X battery cells BTM-Series
BMS-Series/
X Verify float voltage & current at the battery terminals IBEX-Series
BMS-Series /
X Verify cell internal ohmic resistance values IBEX-Series
YEARLY INSPECTIONS
Maintenance Activities (Must perform ALL items checked for your
VLA VRLA NiCd EEPS Solution
battery type in addition to monthly and quarterly inspections)
X Verify specific gravity of all battery cells SG-Series
X Verify AC ripple current IBEX-Series
X X Record each cell temperature IBEX-Series
BMS-Series/
X X X Verify cell-to-cell terminal connection resistance IBEX-Series
Inspect cell condition of each cell in contrast to the monthly inspection. Verify
X X N/A Visual
the structural integrity of the battery rack
Ordering Information
No. Model # Description
1 Ultra Max Plus Kit IBEX-Ultra Battery Tester, SG-Ultra Max Digital Hydrometer, Exmons Ultra Plus Software
IBEX-Ultra Kit
Portable Battery Testers
Product Advantages
• IEEE Recommended: Meets IEEE Std 1188-1996 and 2005 “Rec-
ommended Practice for Maintenance, Testing, and Replacement for
Stationary Applications
• Precise & Repeatable: Utilizes a patented ripple-removing algo-
rithm
• Durable: Simple design with no moving parts
• Online Tester: Test batteries while they are in service
• Fast: Automatically measures and stores data in just 3-4 seconds
• Comprehensive Battery Diagnostic Software: Available software
provides an easy to use interface for data management, trending
analysis, exporting to excel, viewing graphs and creating reports
IBEX-Ultra with 4-Pin Test Leads and CT Clamp Meter
• Battery Bank Management: Upload battery bank and alarm infor-
mation to the IBEX from the included software
• Charging ripple current analysis (%) with IBEX-Ultra
IBEX-SERIES
Technical Specifications
Battery Types: VLA, VLRA, Ni-Cad, & Others
Ordering Information
No. Model # Description
1 IBEX-Ultra ULTRA Intelligent Battery Examiner Kit with Exmons Ultra Software
2 IBEX-Pro PRO Intelligent Battery Examiner Kit with Exmons Ultra Software
3 IBEX-EX Economy Intelligent Battery Examiner Kit with Serial Comm Data Utility
Product Advantages
• 99.999% Accurate, tests density and temperature simultaneously
SG-SERIES
Technical Specifications
Density: 0.000 – 3.000 g/cm3
Measurement Range: Sample Temperature: 01 – 80 °C (321 – 176 °F)
Viscosity: 0 – 1,000 mPa
Density: 0.001 g/cm3
Accuracy: Temperature: ±0.2 °C (±0.4 °F)
Resolution: 0.0001 g/cm3
Repeatability: 0.0005 g/cm3
Minimum Sample Volume: 2 mL
Communication: IrDA Interface
Display: Backlit LCD SG-Ultra Max Kit
Internal Storage: 1024 Results Kit Includes
Operating Environment: 10 – 50 °C (-15 – 122 °F) • SG-Ultra Max
• 180 mm Sample Tube
Power Requirements: (2) AA Batteries • 2 mL Plastic Syringes
• Luer Adapter 1/4” UNF
Dimensions: 140 x 138 x 27 mm (5.5 x 5.4 x 1.0 in) • IrDA Adapter
Weight: 368 g (13 oz) • Interface for Exporting Data to PC
• Carrying Case
(1) Sample must not freeze in the measuring cell. • Electronic User Manual
Ordering Information
No. Model # Description
1 SG-Ultra Max Digital Hydrometer, Data-Logging, Range: 0.0000 – 3.0000
2 SG-Ultra Max Ex-Petrol Intrinsically Safe Digital Hydrometer, Data-Logging, Range: 0.000 - 3.000
Advantages
• Accurate 99.999% Accurate
• User-Friendly Compact, lightweight, and allows for one-hand measurement.
SG-SERIES
Large LCD display screen with back-light
• Robust & rugged, comes with protective carrying case. Sustains tough field
environments with a sealed housing
• Wireless Communication Infrared data interface for data exchange with a PC
and data export to a printer (data transfer accessories included)
SG-Ultra • Storage of up to 1100 results including sample ID, measurement unit,
temperature correction coefficient, instrument identification, date and time
Digital Hydrometers
• Reliable CE Compliant and One Year
Technical Specifications
Density: 0.000 – 2.000 g/cm3
Measurement Range: Sample Temperature: 01 – 40 °C (321 – 104 °F)
Viscosity: 0 – 2,000 mPa
Density: 0.001 g/cm3
Accuracy:
Temperature: ±0.2 °C (±0.4 °F)
Resolution: 0.0001 g/cm3
Minimum Sample Volume: 2 mL
Communication: IrDA Interface
Display: Backlit LCD
Internal Storage: 1100 Results
Operating Environment: 10 – 50 °C (-15 – 122 °F) SG-Ultra Kit
Power Requirements: (2) AAA Batteries
Dimensions: 229 x 114 x 64 mm (9 x 4.5 x 2.5 in) Kit Includes
• SG-Ultra with Protective Boot
Weight: 360 g (2.7 oz) • Sample Tube (7” x 1/8”)
• IrDA Adapters
178 x 3.175 mm / 7 x 1/8 in. Diameter • SG-Ultra Management Software
Sample Tube Dimensions:
*Custom lengths available • Carrying Case
(1) Sample must not freeze in the measuring cell • User Manual
Ordering Information
No. Model # Description
1 SG-Ultra Digital Hydrometer, Data-Logging, Range: 0.0000 – 2.0000
Advantages Applications
• 99.998% Accurate • Telecom/Communications
• 10x faster than • Utilities
conventional methods • Mining
• Measure specific • Government/Defense
gravity and temperature • Industrial Manufacturing
simultaneously • Motive Power
• Automatic temperature
Digital Hydrometers
Technical Specifications
Specific Gravity of Electrolyte: 0.000 – 1.300
Measurement Range: Available upon request: 0.000 – 1.400
Sample Temperature: -10 – 50 °C (14 – 122 °F)
Accuracy: ±0.002 Specific Gravity
Ordering Information
No. Model # Description
1 SG-1000F Battery Digital Hydrometer, Non-Datalogging, Range: 1.000 - 1.300, °F
2 SG-1000C Battery Digital Hydrometer, Non-Datalogging, Range: 1.000 - 1.300, °C
The DLV-Max kit can also be used to perform a full discharge test on up
to 256 cells by recording up to 11 time-stamped voltage readings for each
DLV-Pro Voltmeter & cell, along with time-stamped load current readings and initial and/or final
DLV-SERIES
SG-Ultra Max Digital Hydrometer SG readings via the SG-Ultra Max. All test data can be uploaded to a PC
using the included Winmeter 5.1 Battery Analysis Software.
Features
• Record, view, & analyze cell voltage,
SG, & temperature readings
Technical Specifications
Item DLV-Pro SG-Ultra Max
Measurement Density: 0.000 – 3.000g/cm3 Kit Includes
Cell Voltage: 0 – 20V
Range Temp: 0 – 80°C (32 – 176°F) • DLV-Pro Voltage Tester
0 – 4V: ±5mV Density: 0.001g/cm 3 • Voltage Test Leads
Accuracy
4 – 20V: ±10mV Temp: ±0.2°C (±0.4°F) • SG-Ultra Max Digital
Hydrometer
Voltage: 8 by 256, 20 by 48
Memory 1024 Sequential Test Results • Carrying Case
SG & Temp: 8 by 256
• Winmeter Analysis
Operating Temp 0 – 40°C (32 – 104°F) -10 – 50°C (-15 – 122°F)
Software
Battery Life 3.7V Li-Ion Rechargeable, 20 Hours Industrial (2) AA, 100 Hours
160 x 76 x 33mm (6.3 x 3 x 1.3in) 140 x 138 x 27mm (5.5 x 5.4 x 1.0in)
Size / Weight
298g (10.5oz) 368g (13oz)
Ordering Information
No. Model # Description
DLV-Pro Data Logging Voltmeter, 0 – 20 VDC
1 DLV-Max Kit
SG-Ultra Max Digital Hydrometer, 0 – 3 g/cm3
Advantages
• 99.995% Accurate, measures in liquids or slurries
• Pressure irrelevant - can monitor density at any depth
• Remote readout at desired distance from probe
• Readout can be chosen in preferred engineering units
• Battery or In-tank operation depending on application
• Determines concentration mix (by volume or mass) of the sample
Large sample temperature ranges (up to 106°C / 220°F)
Digital Hydrometers
•
• Customization available based on user needs Digital Panel Meter
Technical Specifications
Density: 0.550 – 2.000 g/cm3*
Measurement Range: Sample Temperature: 20 – 106 °C (40 – 220 °F) CPVC Probe
Applications
Pressure Range: 0 – 5 atm (operable in vacuum)
Accuracy: ±0.005 g/cm3 • Chemical
Resolution: ±0.001 g/cm3 • Petroleum
Repeatability: ±0.004 g/cm3 • Food & Beverage
• Passivation
Minimum Sample Volume: 310 mL
• Electroplating
Data Transfer: Analog Voltage Data Logger (optional) 4 – 20 mA, dual • Flux Density Control
5 A Relay
• Paper Production
Operating Environment: -20 – 106 °C (-40 – 220 °F) • Coatings
Control Module: 120/240 VAC**
Power Requirements:
Probe: 0 – 5 VDC Kit Includes
Dimensions : 1
Probe Length x Diameter: 280 x 51 mm (11 x 2 in)
• SG-100M Digital Panel Meter
• SG-100M CPVC Probe
Weight: Probe: 2.3 kg (5 lbs) • PVC Cable (Standard
Cable Length: Standard: PVC: 1.2 – 452.4 m (4 – 500 ft) Lengths: 4 ft to 100 ft)
Optional: Teflon: 1.2 – 30.4 m (5 – 200 ft) • Optional: Teflon Cable for
(1) Probe must be mounted vertically and be completely submerged in the test solution. Caustic Solutions
Ordering Information
No. Model # Description
1 SG-100M Digital Panel Meter, CPVC Probe
2 SG-100M Probe Standalone CPVC Probe
3 SG-100M with Relay Digital Panel Meter with Analog Output Board (4-20 mA) or Dual 5 A Relay, CPVC Probe
DM-SERIES
between the two pressure repeaters. Small
variations in the process temperature are
quickly and accurately calculated through
dedicated software.
DM-1000A, DM-1000B, & DM-1000C
Applications
• Industrial Chemical Production: Petroleum, natural gas, oil refining,
Advantages
• Patented technology, pinpoint current leakage fault with grounding
resistance lower than 1MΩ
• Locate faults for both offline and online DC systems
• Adjustable output frequency on Signal Receiver effectively avoids
GFL-1000 Kit interference from DC system itself
Waveform analysis will analyze the interference signal in the circuit
Ground Fault Locators
•
• Wide output voltage and output frequency ranges allow the GFL-1000 to
meet the needs of your electronic equipment
Technical Specifications
Output Voltage: 24, 48, 110, 220, 500, 1000 VDC
Output Frequency: Selectable between 1, 10, 50, 60, 325 Hz
Output Current Limitation: 5 mA or Unlimited (Max 25mA)
Fault Location Sensitivity: ≤ 1 MΩ
Current Detect Sensitivity: AC/DC Circuit: ≥ 0.5 mA Signal Receiver
Quick Search Clamp: 55 mm (diameter), 60 mm (jaw opening)
Kit Includes
Current Sensor: φ8 and φ20 • GFL-1000 Signal Generator
Jaw Opening: 60 mm (2.36 in) • Power Adapter
• Qty. (2) Signal Testing Leads
Display: Backlit Color LCD • Qty. (2) Alligator Clips
• Punctuation Clip
Operating Environment: Temperature: -5 – 40 °C (23 – 104 °F) • Signal Receiver
Power Requirements: 8.4 VDC Li-ion Battery • Qty. (2) Dual-Range Current
Detector
Dimensions: 360 x 260 x 135 mm (14.2 x 10.2 x 5.3 in) • Qty. (2) Batteries
• Battery Charger
Weight: 7 kg (15.4 lbs) • Carrying Case
Ordering Information
No. Model # Description
1 GFL-1000 Ground Fault Locator, Range: 24-1000V, 1-325 Hz
Product Features
TIC-1000 Thermal Imaging / IR Camera • Real-Time thermal imaging
TIC-SERIES
• Hot & cold temperature spot measurements
• Reflected temperature compensation
• Measurement offset correction
Technical Specifications
Ordering Information
No. Model # Description
1 TIC-500 6 Hz Thermal Imaging Camera with standard accessories
2 TIC-1000 50/60 Hz Thermal Imaging Camera with case, software, and standard accessories
Product Features
• SMART Constant Current DC Load Banks with system and cell/
unit voltage monitoring
• Data management software included for data analyzing and
reporting
• Four settings for auto shut-down of discharge: discharge time,
total string end voltage, cell end voltage, discharged capacity
• Parallel connection of two units for increased discharge capacity
SMART DC Load Banks
SLB-SERIES
available to view in the software.
Real-Time Data Logging of Cell Voltage
Technical Specifications
Standard DAC: 1.2V1, 2V, 6V, 12V / Optional: Custom DAC
Cell Voltage:
configurations available upon request
Discharge Current Range: Single Load: 12 – 600A / Parallel Load: Up to 1200A Kit Includes
Ordering Information
No. Model # Description
SMART Constant Current DC Load Bank with Monitoring (12-480V, 100-600A)
1 SLB-Series* *See next page for listing of model numbers
*Add “DAC” after model number for wireless monitoring per cell
17 SLB-48-150 ~ ~ ~ ~ 150 ~ ~ ~ ~ ~
18 SLB-48-300 75 150 175 225 300 ~ ~ ~ ~ ~
19 SLB-48-400 ~ ~ ~ ~ 400 ~ ~ ~ ~ ~
20 SLB-48-500 125 250 290 375 500 ~ ~ ~ ~ ~
21 SLB-48/125-100 25 50 58 75 100 64 100 ~ ~ ~
22 SLB-48/125-200 50 100 116 150 200 128 200 ~ ~ ~
23 SLB-48/125-300 75 150 174 225 300 192 300 ~ ~ ~
24 SLB-48/240-100 25 50 58 75 100 33 52 100 ~ ~
25 SLB-10-288v-200A 50 100 116 150 200 50 75 150 ~ ~
26 SLB-80-100 15 30 35 45 60 100 ~ ~ ~ ~
27 SLB-80-200 30 60 70 90 120 200 ~ ~ ~ ~
28 SLB-125-100 ~ ~ ~ ~ ~ ~ 100 ~ ~ ~
29 SLB-125-200 19 38 44 57 76 128 200 ~ ~ ~
30 SLB-125-300 29 57 67 86 115 192 300 ~ ~ ~
31 SLB-125-400 38 76 89 115 153 256 400 ~ ~ ~
32 SLB-125/240-100 9.6 19 22 29 38 64 100 100 ~ ~
33 SLB-125/240-150 14 30 33.4 43 60 96 150 150 ~ ~
34 SLB-240-150 8 15 17.5 23 30 50 78 150 ~ ~
35 SLB-240-200 ~ ~ ~ ~ ~ ~ ~ 200 ~ ~
36 SLB-380-50 ~ ~ ~ ~ ~ ~ ~ ~ 50 ~
37 SLB-380-100 ~ ~ ~ ~ ~ ~ ~ ~ 100 ~
38 LB-480-100 2.5 5 5.8 7.5 10 16.6 26 50 79 100
Product Features
• LED display for voltage, current, & test duration
• Easily program test parameters with simple keypad
LB-SERIES
• Three test conditions for discharge auto-stop: Test Time, End Voltage,
Exceeded Capacity
• Unit will alarm and end discharge in the event of overheating, abnormal
disconnection of battery, improper polarity detected
• Cooling fans continue to run automatically after each test to ensure
LB-48-300-CC maximum heat protection.
• Previously used parameters saved after powering off the machine
Kit Includes
Voltage Range: Standard: 1 – 480V
Accuracy: Discharge Current: 0.1A Voltage: 0.1V • LB-Series CC Load Bank
Control Precision: ±0.3% / +0.2A • 3 m (10 ft) Discharge
Display: Backlit numeric LED Cables
• 110/220 AC Power Cable
10 – 40 °C (14 – 104 °F) • One-year Standard War-
Operating Environment:
0 –90% relative humidity ranty
Input Voltage: 110/220 VAC 50/60 Hz
Cooling: Forced air cooling
Ordering Information
No. Model # Description
1 LB-24/36/48-150/225/300-CC 24V-150A, 36V-225A, 48V-300A Constant Current DC Load Bank
2 LB-24/36/48-250/375/500-CC 24V-250A, 36V-375A, 48V-500A Constant Current DC Load Bank
3 LB-24/36/48-300/450/600-CC 24V-300A, 36V-450A, 48V-600A Constant Current DC Load Bank
4 LB-48-100-CC 48V-100A Constant Current DC Load Bank
5 LB-48-200-CC 48V-200A Constant Current DC Load Bank
6 LB-48-300-CC 48V-300A Constant Current DC Load Bank
7 LB-48-500-CC 48V-500A Constant Current DC Load Bank
8 LB-48-600-CC 48V-600A Constant Current DC Load Bank
9 LB-80-100-CC 80V-100A Constant Current DC Load Bank
10 LB-480-200-CC 480V-200A Constant Current DC Load Bank
11 LB-480-300-CC 480V-300A Constant Current DC Load Bank
Technical Specifications
LB-60-30 Load
120VAC Single Phase: .33, .66, .66, 1.66, 3.33, 3.33 KW Product Features
240VAC Single Phase: .66, 1.33, 1.33, 3.33, 6.66, 6.66 KW • Portable, lightweight,
Steps:
208VAC Three Phase: 1, 2, 2, 5, 10, 10 KW and durable
0-150V Voltmeter • Temperature sensor
LB-60-30
0-100A Ammeter removes load when
Meters:
55-65HZ Frequency Meter
AC Load Banks
over-temperature is
120VAC Single Phase: 1.6, 1.6, 3.2, 3.2, 3.2 KW detected
LB-60-100 240VAC Single Phase: 6.5, 6.5, 13, 13, 13 KW • Easy-to-use switches
Load Steps: 208VAC Three Phase: 10, 10, 20, 20, 20 KW & controls for fan, load
480VAC Three Phase: 12.5, 12.5, 25, 25, 25 KW steps & master load
0-600V Voltmeter • Low-noise, high velocity
LB-60-100
0-250A Ammeter cooling system
Meters:
55-65HZ Frequency Meter • Power indicator lights
LB-400-72 • Quick connect for cables
200VAC Three Phase: 9, 18, 27, 36, 42, 54, 63, 72 KW
Load Steps:
0-250V Voltmeter
LB-400-72
0-250A Ammeter
Kit Includes
Meters:
360-440HZ Frequency Meter
LB-400-100D 200VAC Three Phase: 10, 19, 28, 37, 46, 55, 64, 73, 82, 91, 100, 109 • LB-Series AC Load Bank
Load Steps: KW • Portable Carrying Case
48-600V Voltmeter • 10’ Cables
LB-400-100D • User Manual
0-999A Ammeter
Meters:
360-440HZ Frequency Meter
Ordering Information
No. Model # Description
1 LB-60-30 60HZ 120/240VAC SINGLE PHASE 208V 3PHASE 30KW
2 LB-60-100 60HZ 480/208 3PHASE 100KW AT 480VAC AND 80KW AT 208VAC
3 LB-400-72 400HZ 72KW IN 8 9KW STEPS UP TO 72KW CONTINUOUS
4 LB-400-100D 400HZ 100KW IN 12 STEPS 10, 19, 28, 37, 46, 55, 64, 73, 82, 91, 100
LB-SERIES
Features
• Designed for testing cells of 1.2V, 2V, 6V, and 12V
• 3-in-1 functionality: charger, discharger, and activator (used
separately or comprehensively)
• Accurate test results with vivid waveforms
LB-1000
• Designed to charge/discharge single and multi-cell batteries
Technical Specifications
Charge Current per Cell Voltage:
1.2V: 1 – 50A 2V: 1 – 100A 6V: 1 – 30A 12V: 1 – 30A
Discharge Current per Cell Voltage: Kit Includes
1.2V: 1 – 25A (1)
2V: 1 – 100A 6V: 1 – 30A 12V: 1 – 30A
• LB-1000 Main Unit
• Voltage Test Leads
Charge & Discharge Voltage per Cell Voltage: • Positive & negative Load
1.2V: 0.9 – 1.6V 2V: 1.7 – 2.4V 6V: 5.4 – 7.2V 12V: 10.2 – 15V Cables
• AC Power Cord
Display: 128 x 64 pixel color LCD
• LB-1000 Analyzing
Power Requirements: AC 110/60Hz or AC 230/50Hz(2) Software
Operating Environment: 0 – 50°C (32 – 122°F), 5 – 90% RH • Carrying Case
• User Manual
Dimensions: 40 x 30 x 20 cm (15.7 x 11.8 x 7.9 in)
Weight: 10 kg (22 lbs)
(1) Available discharge current per 1.2V cells can vary depending on battery capacity.
(2) Desired input voltage must be stated at time of order.
Ordering Information
No. Model # Description
1 LB-1000 Battery Charger, Discharger, Activator for 1.2V, 2V, 6V, & 12V Cells
Features
• 5 Main Functions: Regenerator, Power Supply, Discharger
Internal Resistance Tester, and Cold Cranking Ampere (CCA)
BR-SERIES
Tester
• Save money in battery replacement costs by extending
battery life more than double the original lifespan
BR-200 Regenerator & Discharger • Easy to use LCD power display - see measurements and
condition in real-time
• Over-voltage protection - maintains low battery temperature
Kit Includes during restoring
• BR-200 Battery Regenerator & Discharger • Innovative pulse technology allows charging and restoring
Battery Regenerator
Technical Specifications
Battery Voltage: Standard DC 6V, 8V, 12V
Battery Types: Lead Acid (20Ah - 300Ah)
Input Power: AC 80 - 120V, 210 - 250V / 50-60Hz
Max Output: 240W (DC 6V: 10A and DC 8V & 12V: 15A)
Discharge Capacity: Approx. 420 Watts
Maximum Discharge Current: 30A
Input Voltage: 480V
(Standby) Approx. 20W
Power Consumption:
(Maximum) Approx. 200W
Regeneration Method: Charge Current Inclusive High Frequency Pulse
Dimensions 345 x 370 x 170 mm (13 x 14 x 7 in)
Weight: 9 kg (20 lb)
Ordering Information
No. Model # Description
1 BR-200 Battery Regenerator & Discharger for 6V, 8V, and 12V lead-acid batteries
BR-SERIES
Features
• 3 Main Functions: Battery Regenerator, Charger, and Power Supply
• Universal design - can regenerate all types of lead-acid, GEL and AGM
batteries
• Save money in battery replacement costs by extending battery life more
than twice the original lifespan
• User-friendly 8 inch digital touch screen to program tests and view history
Battery Regenerator
• Regeneration and charging begins in 5-simple steps using touch screen
• Over-voltage & surge protection - maintains low battery temperature
BR-500 Regenerator & Charger
during restoring
• Innovative pulse technology allows charging and restoring simultaneously
• Pulse technology restores up to 50% faster than other regenerators
• Save & print reports when results are transferred from the BR-500 to a
PC via USB - allowing a detailed analysis of the regeneration process
Technical Specifications
Battery Voltage: Nominal DC 2 - 96V
Battery Types: Lead Acid (40 - 3,000Ah)
Input Power: AC 210 - 250V / 50 - 60 Hz Kit Includes
• BR-500 Battery
Max Output: 3.00KW Regenerator & Charger
(Standby) Approx. 20W • Regenerator Cables
Power Consumption: • AC Power Cord
(Maximum) Approx. 2.5W
• User Manual
Regeneration Method: Charge Current Inclusive High Frequency Pulse
Dimensions 480 x 400 x 1010 mm (19 x 16 x 40 in)
Weight: 50 kg (110 lbs)
Ordering Information
No. Model # Description
1 BR-500 Battery Regenerator, Charger & Power Supply for 2 - 96V lead-acid, GEL or AGM batteries
Features
• Built-in Intelligence makes it easy to correctly configure charger for battery &
site conditions
• Battery Check System automatically tests battery to reduce risk of expected
application shutdown
• Black Box Data Recorder helps spot previously hidden problems
• Advanced User Interface, USB PC Utility provide easy to understand system
status & control
• Modbus Communication Option provides remote monitoring
EnerGenius Control Panel
Technical Specifications
AC Input Voltage: 120/208/240 VAC, 60 Hz or 50/60Hz
DC Output Voltage: 12, 24, 48, 11/220 or 220/240 VDC nominal
Applications
Current Ratings: 6, 12, 16, 25, 35, 50 Amps • Electric Utility Substations
Voltage Regulation: +0.25% • Switchgear
• Refineries & Chemical Plants
Current Limit Adjust: 33% – 110% rated output • DC Control Systems
Operating Environment: -20 – 50 °C (-4 – 122 °F) Recommended • Engine Starting
• Oil & Gas Pipelines
Agency Compliance: UL Listed
• Offshore Platforms
Q1 Housing: 330 x 493 x 448 mm (13 x 19.4 x 17.6 in)
Dimensions1:
Q2 Housing: 409 x 600 x 707 mm (16.1 x 23.6 x 27.08 in)
(1) Charger housing offered in two sizes, housing weight can vary based on specifications.
Ordering Information
No. Model # Description
1 EnerGenius IQ Single Phase Battery Charger - Request Order Form to build your own custom model
Stationary float battery chargers are commonly used in the following industries:
utilities & telecommunications, manufacturing, uninterrupted power systems
(UPS), transportation, and many more.
Features
• 5 Year Product Warranty
• Universal main control board operates in any AT Series charger
AT10.1 & AT30 Chargers • Alarm assembly with local LEDs and summary relay contact for AC Failure,
DC Failure, High VDC, Low VDC, Positive(+) and Negative(-) ground fault
BC-SERIES
• AC input and DC output circuit breakers
• High DC voltage shutdown
• Forced load share during parallel operation
• Front panel controls can be disabled for security
Technical Specifications
Battery Chargers
Group 1 (6 – 25 ADC) Voltage: 25 – 1000 ADC Voltage:
120/208/240Vac Multi-tap 60Hz 208 VAC 60Hz
480 VAC 60Hz 240 VAC 60Hz
220 VAC, 380/416Vac 50/60Hz 480 VAC 60Hz
VAC Input: 550-600 VAC 50/60Hz 550-600 VAC 60Hz
Group 2 (30-100 ADC) Voltage: 220 VAC 50/60Hz
120, 208, 240 or 480 VAC 60Hz 380 VAC 50/60Hz
220 VAC, 380 or 416 VAC 50/60Hz 416 VAC 50/60Hz
550-600 VAC 50/60Hz
Input Voltage Tolerance: +10%, -12% +10%, -12%
Input Frequency Tolerance: ±5% ±5%
Efficiency: 85-90% typical for 130 VDC at 50-100% load 85-90% typical for 130 VDC at 50-100% load
VDC Output: 12, 24, 48, or 130 VDC nominal 12, 24, 48, or 130 VDC nominal
GROUP 1: 6, 12, 16, 20, 25 A 25, 30, 40, 50, 75, 100,125, 150, 200,
Current Ratings:
GROUP 2: 30, 40, 50, 75, 100 A 250, 300, 400, 500, 600, 800, 1000 A
110% rated current at maximum equalize 110% rated current at maximum equalize
Continuous Rating:
voltage at 50 ºC (122 °F) voltage at 50 ºC (122 °F)
Current Limit Adjust Range: 50% to 110% rated output 50% to 110% rated output
Voltage Regulation: ±0.25% for line, load and temp. variations ±0.25% for line, load and temp. variations
Electrical Noise: 32dBrnc 32dBrnc
Surge Withstand Capability: Meets IEEE-472, ANSI C37.90a Meets IEEE-472, ANSI C37.90a
Ambient Temperature: -18 – 50 °C (0 – 122 °F) Ambient Temperature: -18 – 50 °C (0 – 122 °F)
Operating Environment:
Relative Humidity: 95% Relative Humidity: 95%
Ordering Information
No. Model # Description
1 AT10.1 Single-Phase Battery Charger with 12, 24, 48, 130 VDC & 6 – 100 ADC Output
2 AT30 3-Phase Battery Charger with 12, 24, 48, 130 VDC & 25 – 1,000 ADC Output
Product Features
• Soft start charge cycle
• Voltage drop compensation
• Protection against reverse polarity
• High frequency switching technology
BC-SERIES
Ordering Information
No. Model # Description
1 MP-24-80 24V-80A Output, 480V-4.3A Input Battery Charger (32 kg / 70 lbs)
2 MP-24-100 24V-100A Output, 480V-5.4A Input Battery Charger (32 kg / 70 lbs)
3 MP-24-120 24V-120A Output, 480V-6.4A Input Battery Charger (34 kg / 77 lbs)
4 MP-24-150 24V-150A Output, 480V-8A Input Battery Charger (34 kg / 77 lbs)
5 MP-36-80 36V-80A Output, 480V-5.4A Input Battery Charger (32 kg / 70 lbs)
6 MP-36-100 36V-100A Output, 480V-8A Input Battery Charger (32 kg / 70 lbs)
7 MP-36-120 36V-120A Output, 480V-9.6A Input Battery Charger (34 kg / 77 lbs)
8 MP-36-150 36V-150A Output, 480V-12A Input Battery Charger (34 kg / 77 lbs)
9 MP-48-50 48V-50A Output, 480V-5.4A Input Batter Charger (28 kg / 62 lbs)
10 MP-48-60 48V-60A Output, 480V-6.4A Input Battery Charger (32 kg / 70 lbs)
11 MP-48-80 48V-80A Output, 480V-8.6A Input Battery Charger (32 kg / 70 lbs)
12 MP-48-100 48V-100A Output, 480V-10.7A Input Battery Charger (32 kg / 70 lbs)
13 MP-48-120 48V-120A Output, 480V-12.9A Input Battery Charger (34 kg / 77 lbs)
14 MP-48-130 48V-130A Output, 480V-13.9A Input Battery Charger (34 kg / 77 lbs)
15 MP-48-150 48V-150A Output, 480V-16.1A Input Battery Charger (34 kg / 77 lbs)
BC-SERIES
48-E-Z-GO Yamaha G19, YDRE
Vehicle: 36V E-Z-GO 48V E-Z-GO Yamaha G9, 48V Club Car
TXT G22 Yamaha
G14, G16
Charger Kit
GC-EZ36 GC-EZ48 GC-EZTXT48 GC-CC36 GC-CC48 GC-YAM GC-YDRE
Part #:
Connection
Technical Specifications
Voltage: 36V / 48V Features
• Fully automatic battery charger for
Universal Input: 100-240V AC
golf cart batteries
Standard Flooded Lead -Acid • Thermal cut-off and automatic
Battery Types: overload protection
Optional: AGM or Gel
• Short-circuit and reverse polarity
36V-E-Z-GO protection
48V-E-Z-GO • Begin charge cycle with batteries
as low as 2 volts
48V-E-Z-GO TXT • Float feature allows for batteries to
Vehicle Types: 36V Club Car / Yamaha G9, G14, G16 maintain full charge at the end of
charge cycle
48V Club Car • Lightweight and portable with
Yamaha G19, G22 carrying handle
YDRE Yamaha
Display: LED Display: Red / Yellow / Green Lights Kit Includes
• GC-1000 Main Body
Dimensions: 178 x 305 x 102 mm (7 x 12 x 4 in) • DC Connection Cable Plug
(specific for golf cart model)
Weight: 5.1 kg (11.25 lbs)
• User Manual
Compliance: UL Approved
Ordering Information
No. Model # Description
High Frequency Golf Cart Battery Charger
1 GC-1000*
*Specify Connection Cable Type when Ordering
Smoke Detection
The photoelectric smoke sensor detects minute combustion products from smoldering wire
insulation, battery cases, and other material. When smoke is detected, a distinctive alarm is
emitted from the 80db horn and a separate dry contact switch is activated. At this time, the
exhaust fan is inhibited in order to deny the fire increased oxygen from outside air.
HGD-3000i
Temperature, Loss of Power, & Intrusion
HGD-SERIES
During normal operation and in the absence of an alarm condition, an internal thermostat will turn
on the exhaust fan at a preset temperature to reduce heat build-up in the room. Loss of power to
the unit will also generate a dry contact alarm. Additionally, an optional infrared intrusion alarm will
trigger a silent dry contact switch.
Features
• Highly sensitive and stable solid state hydrogen sensor
• Sensitive photoelectric smoke detector module
• Internal thermostat for automatic exhaust fan control at 40°C (104°F) with ±5° adjustable
Hydrogen Gas Detectors
range
• Save insurance costs - reduce insurance premiums when placed in battery charging rooms
Technical Specifications
Detection: Hydrogen Gas, Smoke, Temperature, Intrusion
HGD-3000: 10A Relay for Exhaust Fan, 1A Relay for Loss of
Power, 1A Relay for Smoke Alarm, 1A Relay for Intrusion, 1A
Alarms:
Relay for 2% H2 Concentration
HGD-2000: (2) Form C Relay
HGD-2000 Control Box
Relay Connections RJ45, Punch-Down Block
Mounting: (4) 4.5 mm (3/16 in) screws
Kit Includes
Operating Environment: Temperature: -10 – 40 °C (14 – 104 °F)
Standard: 85 – 265 VAC, 50/60 Hz • Hydrogen Gas Detector
Power Requirements:
Optional: 17 – 60 VDC or 12VDC • User Manual
IEEE Standard 450; National Fire Protection Agency (NFPA) Ar- • Optional: Silent-Alarm Add-on
ticle 64; NFPA 2: Hydrogen Technologies Code; Uniform Building • Optional: Control Box or
Compliance: Code (UBC) Section 6400; National Electric Code (NEC) Section Breakout Box
480.9 (A); NEC 501.125 (B); NEC 501.105 (1)-3 - use in Class 1 • Optional: Junction Box
Division 2 Group B.
Dimensions: 178 x 120 x 55 mm (7 x 4.75 x 2.5 in)
Ordering Information
No. Model # Description
1 HGD-2000 Hydrogen Gas Detector
2 HGD-3000 Hydrogen Gas / Smoke Detector
3 HGD-3000i Hydrogen Gas / Smoke Detector with Infra-red Intrusion Alarm
4 Control Box Remote control box with connection cable for the HGD-2000
5 Breakout Box Breakout box for the HGD-3000 or HGD-3000i
Product Overview
The HGVS-1000 Hydrogen Gas Ventilation System is a forced
ventilation fan system used in battery charging rooms and other
areas where hydrogen may be present. This is to be used in
conjunction with the HGD-2000 and HGD-3000 Hydrogen Gas
Detectors. The hydrogen gas detector is mounted in the highest
part of the room and the HGVS-1000 vent fan is mounted through
the outside wall.
The system has four fans factory-rated at 850 CFM each. This
conforms to N+1 for 2550 CFM. The vent is equipped with a
“Positive Airflow Shut Off” feature. These doors can be closed
by an external electric command, and will stop any airflow from
passing through the fans. The HGVS-1000 is primarily set up to
VS-SEIRES
HGVS-1000 exhaust air but can be reversed to source forced air into a room.
Ventilation Systems
• Automatic Operation and Continuous 24/7 • Fan can be provided with an optional firefighter shut down
Monitoring lever
• High Sensitivity and Stability • Fan can be provided with an optional emergency horn &
• Long Life-Span for Reliable Monitoring flashing light
• Inexpensive protection for equipment and
personnel
• Two-Year Warranty
Applications
Technical Specifications • Utilities and Power
Input: Positive shutoff control, N.O. Dry Contacts Plants
Connections: • UPS Power
Output: 1% Fan Running, 2% Alarm, N.O. Dry Contacts
Systems
Mounting: (4) 38 mm (1.5 in) Standard 607 mm (24 in) • Fuel Cell Test
Positive Shut-Off: Dry contact activated, manually reset Stations
• Nuclear Waste
Dimensions: 24 - 48 VDC or 115 VAC as ordered, ground stud
Reforming
Fan: 23 kg (51 lbs) • Hydrogen
Weight:
Rain Shield & Damper: 10.9 kg (24 lbs) Refueling Stations
• Fire Department
(4) fans rated at 850 CFM Total 3400 CFM
Safety Standard: • Battery Suppliers
N+1 (3) Fans at 850 CFM Total 2550 CFM for 777 sq. m (2550 sq. ft) • Battery Charging
Mounting wing placement, room exhaust source, small or large rain Rooms
Options: • Motive Power
shield, N.O. to N.C., custom features on request
• Golf Cart
Ordering Information
No. Model # Description
1 HGVS-1000 Hydrogen Gas Ventilation System (used in conjunction with HGD-2000 and HGD-3000)
Portable Resistance
Battery Monitoring Digital Hydrometers SMART Load Testing DC Load Testing
Testing
Voltage & Ground NERC Compliance NERC Compliance Thermal Runaway Electrolyte Level
Monitoring Portable Testing Monitoring Monitoring Monitoring
Data-Logging
Battery Regenerators Ground Fault Location Gas Detection Battery Charging
Volt Meters
info@eepowersolutions.com
www.eepowersolutions.com
* The content of this information is subject to change without prior notice for the improvement
of the product’s performance.
V1.1