ILS-PTE: Process-Technological

Elements for SIMATIC PCS 7


Product brief February 2001

The "ILS-PTE" software package pro-


vides you with a program library for the
SIMATIC PCS 7 process control sys-
tem, enabling you to automate, operate
and monitor the steps of a process
clearly and easily.
By implementing well-proven function-
alities, which meet the requirements of
various industrial sectors, you obtain a
technological library that offers you a
high-level of standardization due to its
wide range of functions – with all its
advantages during the phases of ten-
der specification, engineering, com-
missioning, qualification and operation.
Function block versions with different
grades of functionality, as well as dis-
play construction statements which
can be centrally modified also enable
the package to be adapted flexibly to
meet specific customer or project
requirements.
A major characteristic of modern pro-
cess control systems is that powerful,
modular software functions are avail-
able for the process control and visual-
ization for standardized process engi-
neering tasks.
The "ILS-PTE" software library (German
abbreviation for Industrial Control Sys-
tem – Process Technical Elements)
provides function blocks whose power-
ful functions permits efficient automa-
tion at the individual control level.
This software library provides the stan-
dards for generating SIMATIC PCS 7
user software in a rational and
cost-effective process.
ILS-PTE
Process-Technological Elements
Individual Control Level Blocks

Based on experience of real applica- Other blocks will be available shortly.


tions, these blocks are suitable for gen- The blocks are characterized by the
eral use in all industries that use following standardized features:
process control systems:
■ Standardized operator control and
· Breweries, monitoring concepts
· Food, beverages and tobacco ■ Four kinds of interlocking option
industries,
■ Consistent instruction type and
· Water supply and sewage treatment, operating state concept
· Cement, ■ Message concept with additional
· Sugar, information on the individual mes-
· Chemicals, sages
· Pharmaceuticals and others. ■ Standardized operating messages
Operator display for PID controller
for each parameter change via the
Even complex tasks, e.g. in chemical OS operating displays
and pharmaceutical process engineer-
ing, can be implemented efficiently all ■ Free user status-word for the freely
the way from the individual control level configurable presentation of addi-
to the recipe control. tional information
The blocks are configured when ■ Checking for parameterization
generating the user software using the ■ Interface to the SIMATIC PCS 7
SIMATIC PCS 7 standards tools, e.g. channel driver blocks
CFC (Continuous Function Chart) ■ Consideration of Quality Code
according to IEC 1131.
■ Interface to BATCH flexible
Their functionality, modularity and con-
■ Standard start-up and time behavior
sistency, e.g. in the operating states, Operator display for analog value
give you the best possible support in ■ Scalable functionality by means of monitoring
performing your task. block versions

ILS-PTE
Process Technology Elements In addition, an integral instruction
The Individual Control Level Blocks generator performs the following tasks:
Using ILS-PTE, even complex tasks · Selection of the instruction type
are implemented efficiently and con- · Evaluation of the interlocking signals
sistently from the individual control · Evaluation of the checkback
level to the recipe control. monitoring
The functional scope of "ILS-PTE Tech- · Evaluation of an external error signal
nological Library V5.0" includes blocks
for the following functions:
· Setting the operating states Operator display for motor control

· Analog output · Formation of the control signal, both


as a static signal and as an pulse
· Analog value monitoring with adjustable pulse duration
· Open/close valves · Activation of the commissioning
· Binary value monitoring mode, i.e. drives can be operated,
· Dosing with coarse/fine flow for example, without interlocks
· Control for one-speed motors
· Control for two-speed motors
· Control for motors with two rotational
directions Operator display for three-way valve control
· Control for speed-controlled drives
· Motorized slide valves
· PID controller
· Controller for multiway valves
· Interlock with logic detail representa-
tion

2
Transitions caused by:
BASIC
Automatic
STATE instructions
T1
Operations T4

T11 T8 T9

BASIC T6 T5
STATE ERROR ACTIVE
DELAYED
DELAYED

T10 T7
Operator display – motor control for
speed-controlled drives Error
T3 T2 FOLLOW-UP
Maintenance displays can be called up
which permit additional settings; those ACTIVE
shown below of for the analog value T1...T11: transition conditions
monitoring:
Operating Status Change diagram

MANUAL
T2
MANUAL
Þ Instructions received from operator T3

AUTOMATIC T2
Þ Instructions received from FOLLOW-UP T1
higher-level control
The ILS-PTE blocks also offer an interface
to BATCH flexible and make the necessary FOLLOW-UP T1
inputs available for this.
Þ Instructions followed up, T3
Example for the view of BATCH flexible: e.g. in local or maintenance mode
AUTOMATIC

Instruction types set via operations or external control signals

Instruction types

The instructions for this can be higher-level operating system. For


received via an operating system OS, each block type – provided this exhib-
via a local operation (remote opera- its a message behavior – 8 message
tion), from a higher-level process or events and total of 10 accompanying
automatic control or directly via an values are available. All message
Below is an example for the display of the on-site operation (external control sig- events and accompanying values that
interlock block: nals). In total, therefore, four different are not occupied by the ILS-PTE block
instruction interfaces and thus four dif- type can be used by the user.
ferent operating levels are available, Each of the maximum of eight mes-
each instruction interface and operat- sages can be disabled and enabled
ing level being assigned to one instruc- individually via an operation in the
tion type. maintenance faceplate. In addition
Message functions for events and there is an option for suppressing all
operations messages by means of an input that
can be interconnected or parameter-
The blocks report different events ized.
(e.g. limit violations or the activation
of the commissioning mode) to the

3
Each value adjustment that is per-
formed via the ILS-PTE standard Benefits & Highlights
operator displays also generates an ■ Engineering and commissioning costs reduced thanks to the high level of
operation message which contains the standardization
following information in the message
■ Well-proven functionality tailored to various industrial sectors
line:
■ Wide range of functions
· Date/time
■ Different function block versions for scalable functionality
· Origin
■ User objects can be modified centrally
· User
■ Adapts flexibly to specific customer requirements
· Operation message text
■ Consistent instruction types and operating states
· Old value
■ Automatic control as well as central and on-site operation
· New value
■ Flexible interlocking options
· Batch description
■ Interface to BATCH flexible
Control functions
· Instruction types:
MANUAL, AUTOMATIC and
FOLLOW-UP mode In addition, the motor and valve blocks Scope of supply / Ordering Data
(see "Instruction Types" diagram on have another power-on option for an
external fault (general/environmental "ILS-PTE Technological Library V5"
page 3) software package
fault).
· Operating states:
· Software for SIMATIC PCS 7 V5.0
BASIC STATE, ACTIVE and ERROR Visualization functions
(requiring acknowledgment), in addi- · Function blocks and operating dis-
tion BASIC STATE DELAYED and · Operating displays with dynamic plays
tooltip texts and symbolic represen-
ACTIVE DELAYED
tation · Electronic documentation
(see "Operating Status Change" dia-
gram on page 3) · User guidance by activation of oper- · Single-user license for use on one
ating elements SIMATIC PCS 7 automation system
· Automatic control as well as central AS 414, AS 416 or AS 417
and on-site operation · Operation and maintenance of rele-
Order No.: 9AE4200-8EA00-0AA0
vant parameters (password-pro-
Interlocking functions tected) Support
All ILS-PTE block types, apart from · Display of interlocking conditions in
Your contact for
those with exclusively analog and logical representation
queries and suggestions:
binary value monitoring functions, · Message processing by means of
recognize in principle four interlocking Siemens AG Karlsruhe
prepared operational and fault mes-
options: Ulrich Neu
sages
· Release for power on Tel.: +49 721 595-6919
Fax: +49 721 595-5121
· Protective interlocking
E-Mail:
· STOP interlocking ILS-PTE.support@khe1.siemens.de
· Disconnection
Each of the four options forces the
ILS-PTE block type into a certain oper- Intranet
ating or processing state. Further up-to-date information can be
found on our Intranet website:
http://intra1.khe1.siemens.de/td/
index1630068_2.htm (only Siemens
internal)

Siemens AG
Organization Group Industrial Solutions and Services
Division Industrial Services
D-76181 Karlsruhe
Federal Republic of Germany © Siemens AG 2001
Subject to change

Order no. E10001-T420-A3-V1-76000


Siemens Aktiengesellschaft Printed in the Federal Republic of Germany
115111 KB 0201 1.0 SR En

Das könnte Ihnen auch gefallen