Beruflich Dokumente
Kultur Dokumente
MK DIMENSIONS
INSTALLATION GASKET
The MK Dimensions products consist of the main product module,
complete with support frame, plus a separate clip on clear protective
frontplate. The product is mounted to the wall, after wiring, and the clear 1. A gasket is also supplied which may prove
protective frontplate is clipped onto the frame.. useful for installation on uneven wall surfaces.
2. Using the gasket with all switches will ensure
1. Ensure the depth of the back box is correct for the product and that it is
compliance to IEC 60669.
fitted securely to the wall.
3. IEC 60669 is intended to guarantee full
2. Install the cables in the normal way and, using the fixing screws supplied,
engagement of the frontplate on uneven
mount the product, minus its frontplate, to the wall. It is important the
surfaces, even when there is a mismatch of as
correct headed screws provided are used as any other may clash with the
much as 1mm between the distance the main
rear of the frontplate.
body of the product is from the wall and that of
3. Do not over tighten the screws, so as to prevent damage or distortion to the front plate.
the product or support frame. Adjust so the frame or module sits squarely
4. Where no gasket is used, if thick wallpapers
on the wall.
are cut such that they fit around the module
4. Care should be taken to ensure product features such as snap fits are but remain under the edge of the frontplate,
not blocked during installation or decorating, preventing correct fitting full plate engagement with the frontplate clips
of frontplates (for example plaster, tile grout, paint etc). may be restricted.
5. Apply clip on frontplate.
1. Align the frontplate with the front of the wall 1. Carefully insert a 4mm screwdriver into
module and press gently in all four corners the slots provided along the bottom edge
until the frontplate clicks into place. frontplate.
2. Gently push along all outer edges to ensure 2. Carefully twist the screwdriver and lift the
the frontplate is securely fitted to the wall frontplate away disengaging the snap fits.
module.
Note: Ensure the correct frontplate is fitted to the correct module or frame.
Care should be taken to ensure product features such as snap fits are not blocked during installation or decorating, preventing correct fitting of frontplates
(for example plaster, tile grout, paint etc).
Decorative Wiring Devices | 17
CABLE MANAGEMENT
Socket outlets, switches and other MK wiring accessories can be mounted in a variety of MK trunking
systems.
TECHNICAL SPECIFICATION
ELECTRICAL
VOLTAGE RATING
250V a.c.
CURRENT RATING
13A DESCRIPTION
TERMINAL CAPACITY A range of socket outlets designed for ease of installation and having all the
Live, neutral & earth advantageous design features of the MK range of wiring devices.
3 x 2.5mm²
3 x 4mm² Sockets are fitted with two earth terminals on a common busbar to provide a
2 x 6mm² (stranded)
double earth facility.
PHYSICAL
AMBIENT OPERATING TEMPERATURE The products can be quickly installed as replacement for existing 13A
–5°C to +40°C sockets or in a new installation.
IP RATING
IP2XD
INSTALLATION
FEATURES
MOULDED ‘ON’ INDICATOR FLASH ON PLASTIC SWITCHES WILL NOT RUB OFF – TOTALLY SAFE
l
OPTIONAL NEON INDICATORS IN THE SWITCH ROCKERS WITH 175° VISIBILITY IN THE
l
ADDITIONAL ELECTRICAL SAFETY FROM DP SWITCH, NEUTRAL ‘MAKE FIRST’, ‘BREAK LAST’
l
FEATURE
SWITCH CONTACTS WITH SILVER CONTACTS ON BOTH SURFACES FOR GOOD CONTINUITY
l
DIMENSIONS (MM)
86 18 146 18
86
86
9 9
Decorative Wiring Devices | 19
STANDARDS AND
APPROVALS
Standards and approvals Dimensions 13A
socket outlets and 2A USB charging outlets
comply with BS 5733 and IEC 61558-2-16.
EMC Compatibility:
IEC 61000-6-1
IEC 61000-6-3
DESCRIPTION
Products are CE marked and meet the
requirements of the Low Voltage, EMC, A range of socket outlets designed for ease of installation and having all the
RoHS and WEEE directives. (where relevant) advantageous design features of the MK range of wiring devices. Dual USB
charging outlets offer end users easy access to power for charging a variety
of devices such as smart phones, tablets and cameras.
TECHNICAL SPECIFICATION
ELECTRICAL
FEATURES
VOLTAGE RATING
220-240V 50/60Hz l MOULDED ‘ON’ INDICATOR FLASH ON ELECTRONICALLY PROTECTED AGAINST AN
l
CURRENT RATING SWITCHES WILL NOT RUB OFF – TOTALLY SAFE OVERLOAD OR SHORT CIRCUIT ON EITHER
13A l 3 PIN OPERATED SAFETY SHUTTER ON 13A USB OUTLET
Combined total 2A drawn from USB outlets
SOCKET OUTLETS USB OUTLETS ARE DESIGNED TO PROVIDE
l
STANDBY POWER l USB 2.0 AND 3.0 COMPATIBLE OPTIMUM CHARGING COMPATIBILITY ACROSS
150mW A WIDE RANGE OF DEVICES
l CAN CHARGE A DEVICE AT UP TO A FULL 2A
TERMINAL CAPACITY PRINTED TERMINAL MARKINGS ON GREY REAR
l
l IF ONLY ONE DEVICE IS CONNECTED TO A USB
Live, neutral & earth MOULDINGS FOR CLEARER IDENTIFICATION
3 x 2.5mm2 OUTLET THE TOTAL OUTPUT CURRENT OF 2A
3 x 4mm2 IS AVAILABLE FROM EITHER OUTLET TOP ACCESS, ANGLED TERMINALS MAKE
l
AMBIENT OPERATING TEMPERATURE 2A IS DIVIDED BETWEEN THE TWO OUTLETS DOUBLE POLE SWITCHING
l
–5°C to +40°C l DIFFERING MANUFACTURERS DEVICES CAN ADDITIONAL ELECTRICAL SAFETY FROM
l
IP RATING BE CHARGED SIMULTANEOUSLY VIA THE TWO NEUTRAL ‘MAKE FIRST’, ‘BREAK LAST’ FEATURE
IP2XD USB OUTLETS SWITCH CONTACTS WITH SILVER CONTACTS
l
MAX. INSTALLATION ALTITUDE l IF THE TOTAL CHARGING CURRENT EXCEEDS ON BOTH SURFACES FOR GOOD CONTINUITY
2000 metres THE RATED LEVEL OF 2A THEN THE DEVICE BACKED OUT AND CAPTIVE TERMINAL SCREWS
l
WILL ENTER A CURRENT LIMITING SAFETY
DUAL EARTH
l
MODE
BOX DEPTH FOR EXTRA
MINIMUM BOX
MODEL WIRING SPACE MINIMUM
DEPTH BOX DEPTH
DIMENSIONS (MM)
25mm* 35mm
DIMENSIONS
*For compliance to BS 1363 use either a 146 18
35mm back box or the K1000 pattress
9
20 | MK DIMENSIONS
STANDARDS AND
APPROVALS
5A Unswitched Socket
BS546:1950
IEC60884-1:2006
5A Switchsocket
BS546:1950
IEC60884-2-3:2006
DESCRIPTION
15A Switchsocket
A range of round pin socket outlets designed for ease of installation and
BS546:1950
having all the advantages and design features of the MK range of wiring
devices. These products can be quickly installed as replacements for
TECHNICAL SPECIFICATION
existing socket outlets or in new installations.
ELECTRICAL
VOLTAGE RATING
250V a.c.
FEATURES
TERMINAL CAPACITY
5A sockets: l TOP ACCESS TERMINALS MAKE WIRING EASIER AND QUICKER
3 x 2.5mm² l INTEGRAL ON INDICATOR ON PLASTIC SWITCHES WILL NOT RUB OFF – TOTALLY SAFE
2 x 4mm²
2 x 6mm² (stranded) l SWITCH CONTACT GAP, 3MM MINIMUM
15A sockets: l DOUBLE POLE SWITCHING
3 x 2.5mm² l TERMINAL SCREWS BACKED OUT
3 x 4mm²
2 x 6mm² (stranded) l ADDITIONAL ELECTRICAL SAFETY FROM NEUTRAL “MAKE FIRST”, “BREAK LAST” FEATURE ON
PHYSICAL
SWITCHED SOCKETS L SWITCH CONTACTS WITH SILVER CONTACT POINTS ON BOTH SURFACES
FOR GOOD CONTINUITY
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C l 5A AND 15A SOCKETS CONTAIN A 3 PIN OPERATED SAFETY SHUTTER
IP RATING l PRINTED TERMINAL MARKINGS ON GREY REAR MOULDINGS FOR CLEARER IDENTIFICATION
IP2XD
DIMENSIONS (MM)
86 21 86 24 86 21
86
86
86
N
L
Supply TOP
L1 L2 N
L1 L2 N
9
To Fan Unit without Timer
Rear view of (see Fan Unit Intructions)
Fan Isolator N
WIRING DIAGRAMS L (switched)
Two pole switching for fan units without timers Three pole switching for fan units incorporating timers
N N
L L
Supply TOP Supply
TOP
L1 L2 N
L1 L2 N
L1 L2 N
L1 L2 N
N N
L L
Supply TOP Supply
TOP
L1 L2 N
L1 L2 N L1 L2 N
L1 L2 N
To Fan Unit without Timer
Rear view of (see Fan Unit Intructions) To Fan Unit with Timer
Fan Isolator N Rear view of (see Fan Unit Intructions)
L (switched) Fan Isolator N
L (unswitched)
L (switched)
STANDARDS AND
APPROVALS
Shaver/Toothbrush supply units comply
with BSEN 61558-2-5:1998
20VA
SAFETY INTERLOCKED SHUTTERS TO PREVENT INSERTION OF TWO PLUGS SIMULTANEOUSLY
l
No load voltage < 275V
ONLY ONE SIZE OF SCREWDRIVER REQUIRED FOR INSTALLATION
l
TERMINAL CAPACITIES
Each terminal will accommodate 1 x 4mm² or FRONT PLATE FIXING SCREWS RETAINED ON REAR CASE MOULDING
l
PHYSICAL
SUITABLE FOR USE WITH ELECTRIC TOOTHBRUSH CHARGERS
l
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
INSTALLATION
wall mounted.
9
Decorative Wiring Devices | 23
IP RATING
IP2XD
2000 metres
INSTALLATION
FEATURES
OPTIONAL INDICATORS IN THE SWITCH ROCKERS WITH 175° VISIBILITY IN THE
l
ALL SUPPLY AND LOAD CABLES CAN BE CUT AND STRIPPED TO THE SAME LENGTH
l
MOULDED ‘ON’ INDICATOR FLASH ON SWITCHES CANNOT RUB OFF – TOTALLY SAFE
l
LAST’ FEATURE
SECURE CABLE AND FLEXIBLE CORD CONNECTION
l
Note: These switches are not recommended for switching large banks of PCs
Decorative Wiring Devices | 25
TECHNICAL SPECIFICATION
ELECTRICAL
FEATURES
VOLTAGE RATING
250V a.c. l POSITIVE SWITCH ACTION
CURRENT RATING l POSITIVE DOUBLE POLE SWITCHING
32A Switch (Resistive load)
50A Switch (Resistive Load)
l TOGGLE ACTION SWITCHES
l METAL FRONT PLATES AVAILABLE
SWITCH
3mm contact gap l REPLACEABLE NEON INDICATORS
Double pole operation
l WIDE PRODUCT CHOICE
TERMINAL CAPACITY 50A SWITCHES
4 x 4mm²
3 x 6mm²
1 x 10mm² DIMENSIONS (MM)
1 x 16mm²
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C MH4305
86
IP RATING
IP4X
MH4336
17
12
Note: These switches are not recommended for switching large banks of PCs
26 | MK DIMENSIONS
PLATESWITCHES
STANDARDS AND
APPROVALS
All MK plateswitches comply with
BS EN 60669-1:1999.
TECHNICAL SPECIFICATION
ELECTRICAL
VOLTAGE RATING
250V a.c.
CURRENT RATING
DESCRIPTION
10A – no derating when used on fluorescent or inductive MK plateswitches are designed to blend in with the decor, whilst
loads complementing a wide range of other MK wiring devices. They are designed
20A – no derating when used on fluorescent or inductive for easy installation in plasterdepth boxes and are suitable for controlling
loads lighting circuits in domestic, commercial and industrial applications.
TERMINAL CAPACITY
4 x 1mm²
4 x 1.5mm²
3 x 2.5mm² FEATURES
2 x 4mm² l TWO WAY SWITCHES CAN BE WIRED AS ONE OR TWO WAY
1 x 6mm²
l MATCHING GRID SWITCHES AVAILABLE IN 10 OR 20A RATINGS
CONTACT GAP
3mm switch contact gap l 3MM SWITCH CONTACT GAP
PHYSICAL l POSITIVE SWITCH ACTION
AMBIENT OPERATING TEMPERATURE l TOP ACCESS, BACKED OUT AND CAPTIVE TERMINAL SCREWS
–5°C to +40°C
IP RATING
IP2XD
DIMENSIONS (MM)
86
11
86
12
Decorative Wiring Devices | 27
PLATESWITCHES
DIMENSIONS (MM)
86
9
One-way switching
86
Common Common
L L
1 1
N N
WIRING DIAGRAMS Lamp/s
Lamp/s
Two-way switching
Common Common Common
Common Common
L L 2 Two-way switches
1 1 2 1
L 1 2 Two-way switches 2 1
N
N N
Lamp/s Lamp/s
Lamp/s
Dotted lines show alternative switch positions
Dotted lines show alternative switch positions
Common Common
Two-way switching
Common Common
3 wire1 control
L 2 Two-way switches
Common 2 1 Common
L
1 2 Two-way switches 1 2
N
L
1 2 Two-way switches 1 2
N SW.L
N SW.L
Lamp/s
Dotted lines show alternative switch positions Lamp/s
Lamp/s Dotted lines show alternative switch positions
Dotted lines show alternative switch positions
DIMMER SWITCHES
PHYSICAL
AMBIENT OPERATING TEMPERATURE
0°C to +40°C
86
IP RATING
IP2XD
9
Decorative Wiring Devices | 29
The light output of some LED lamps may appear to be too dim or invisible when the dimmer knob is at the minimum dim level.
Follow the steps below to adjust the minimum brightness level. This feature is primarily for adjusting the minimum brightness
level of the LED lamp although it can be used for other load types.
For a double gang dimmer, the light level of each gang has to be adjusted separately.
Push to
switch OFF Min
3. Turn on the dimmer and immediately rotate the knob 3 times in full rotary span within 5 seconds.
Push to
switch ON Max Min Max
NOTE: Wait for 3 seconds, the lamp will then dim to minimum before automatically brightening to about 30% level.
Turning/pushing the dimmer knob before the end of automatic brightening will end access to programming mode
NOTE: Some LED lamps may not work properly if the brightness level is set too low thus it is recommended to keep the
brightness level of the lamp at a visible level. The dimmer will exit programming mode automatically without saving the new
setting if there is no dimmer knob movement for 15 seconds. The dimmer will restore its factory default light level.
6. Confirm the new setting and exit programming mode by turning OFF the dimmer.
Push to
switch OFF
DIMMER SWITCHES
FEATURES l SOFT START, WHICH GRADUALLY INCREASES THE LIGHT OUTPUT FROM THE
LOAD OVER 1 TO 3 SECONDS AFTER SWITCH ON. THE SOFT START FEATURE
Intelligent and LED Intelligent Dimmer Switches IS ALSO PARTICULARLY BENEFICIAL WHEN USED TO DIM MAINS VOLTAGE
incorporate the following advanced features TUNGSTEN HALOGEN LAMPS WHICH INHERENTLY HAVE A VERY HIGH INRUSH
CURRENT AT SWITCH ON
l SUITABLE FOR DIMMING LOW VOLTAGE HALOGEN LAMPS VIA GOOD QUALITY,
FULLY DIMMABLE ELECTRONIC OR WIRE-WOUND TRANSFORMERS. IN
ADDITION, LED INTELLIGENT DIMMER SWITCHES ARE SUITABLE FOR Standard Dimmer Switches
DIMMABLE LED BULBS FOR INCANDESCENT REPLACEMENT.
l SUITABLE ONLY FOR USE WITH FUSED GLS TUNGSTEN FILAMENT LAMPS TO BS
l CAN BE USED WITH GOOD QUALITY MAINS VOLTAGE HALOGEN LAMPS
EN 60064 AND BS EN 60432-1
INCORPORATING GU10 BASES. PLEASE CHECK WITH LAMP MANUFACTURER
TO DETERMINE SUITABILITY l ONE WAY DIMMER SWITCHES INCORPORATE MANUAL SOFT START
l LOAD CURRENT SENSING: l INCORPORATE THERMAL SWITCHES FOR PROTECTION AGAINST OVERLOAD
THESE DIMMERS CONTINUOUSLY MONITOR THE LOAD CURRENT TO HELP
PROTECT AGAINST OVERHEATING IN WIRE WOUND TRANSFORMERS AND TO
PREVENT OVERLOADING OF THE DIMMER FOR LONG TERM RELIABILITY
wall mounted. 60-625W function without dimming 40-375W function without dimming 40-375W function without dimming
N
Supply 230V a.c. - 50Hz Load L C2 DIMMER
N Load C > 375-600W dim to
> 625-750W dim to 68V±8V r.m.s. > 375-500W dim to 68V±8V r.m.s. minimum level
> 750W switch off > 500W switch off > 600W switch off
Two-way switching
(only one switching
Two-way dimmer can be used)
(only one dimmer can be 2used)
way switch
2 wayL1switch L1
N Load C
Supply 230V a.c. - 50Hz
L12 L12 DIMMER
N Load C
L
Supply 230V a.c. - 50Hz
L2 L2
C DIMMER
L C
Wires must be connected to the correct dimmer terminals.
DO NOT connect earth to dimmer.
Wires must be connected to the correct dimmer terminals.
DO NOT connect earth to dimmer.
EURO FRONTPLATES
FEATURES
1, 2 & 4 MODULE EURO FRONTPLATES
l
1 & 2 MODULE EURO FRONTPLATES FITTED WITH EARTH STRAP AND 1 EARTH TERMINAL
l
4 MODULE EURO FRONTPLATES FITTED WITH EARTH STRAP AND 2 EARTH TERMINALS
l
DIMENSIONS (MM)
86 86
11
86
86
146
11
86
9
32 | MK DIMENSIONS
COMBINATION PLATE
STANDARDS AND
APPROVALS
Dimension 13A socket outlets comply with
BS 1363: Part 2:2016.
236
10
88
Decorative Wiring Devices | 33
STANDARDS AND
APPROVALS
All Dimensions switches comply with
BS EN 60669-1:1999.
TECHNICAL SPECIFICATION
ELECTRICAL
VOLTAGE RATING
250V a.c.
CURRENT RATING
1way/2way – 10AX or 20AX versions available
All Push switches – 10A only
Intermediate – 20AX only
DESCRIPTION
Double Pole – 20AX only Dimensions Grid Switch Modules require a separate frontplate, when
Centre Off – 10A only ordering ensure the appropriate module and frontplate is selected.
TERMINAL CAPACITY
All products
4 x 1mm²
4 x 1.5mm² FEATURES
3 x 2.5mm²
2 x 4mm²
SWITCH CONTACTS WITH SILVER CONTACTS ON BOTH SURFACES FOR GOOD CONTINUITY
l
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP4X
BOX TYPES
Flush
L
1
InspirationOne-way switching
starts here Common
N
WIRING DEVICES TECHNICAL
L
1
Lamp/s
N
Lamp/s
One-way switching
Common Common Common
N
Common Common
N DIAGRAMS
WIRING
L 2 Two-way
1 switches
Lamp/s 2 1
Lamp/s
Dotted lines show alternative switch positions
One-way switching
N
Two-way switching – 2 wire control
Lamp/s
Two-way switching Dotted lines show alternative switch positions
Common Common Common
L L
1 Common Common 1 2 Two-way switches 2 1
LN N
1 2 Two-way switches 1 2
Two-way switching
Common Common
3 wire control
N SW.L Lamp/s
Common Dotted lines show alternative switch positions
Lamp/s
L
1 2 Two-way switches 1 2
Lamp/s
L
1Dotted lines show alternative switch positions
N SW.L
N2 wire control Two-way switching
Two-way switching plus intermediate switching
–
Common Common Lamp/s
Dotted lines show alternative switch positions
Lamp/s Common Common
3
2 wire
Two-way control
L 1 switches 2 1
L
1 2 Two-way switches 1 2
N
Common 2 1 Common
intermediate
Dotted lines show alternative switching
Common Common
switch positions Common 2 1 Common
N
Lamp/s
L
Lamp/s
1 2 switch 2
Intermediate
1 switch
Dotted lines show alternative switch positions Common
Common
1 N
2
Two-way
switch
intermediate switching Lamp/s Common Common
N SW.L
2 1
1 3 wire control Dotted lines show alternative switch positions
L
2 Two-way switches 1 2
Two-way Intermediate Two-way
L
2 1 switch
Lamp/s 1 2 switch 1 2 switch
Lamp/s
N SW.L
Two-way Common
plus 2 1
Dotted lines show alternative switch positions
Common
Lamp/s
Dotted lines show alternative switch positions
2 intermediate switching
Two-way Intermediate Two-way
1 switch
L
1 switch 2 1 2 switch
Common 2 1 Common
3 wire control
N
Two-way Intermediate Two-way
L
2 1 switch
1 2 switch 1 2 switch
Note: Switches incorporating indicator or locator illumination must be disconnected before carrying out any site installation testing.
N SW.L
Lamp/s
Terminal positions may alter. The above diagrams are to show wiring layout.
Dotted lines show2alternative
Common 1 switch positions Common
GRID FRONTPLATES
86 86 12
86
86
146 146 14
86
86
146 146 14
146
146
9
36 | MK DIMENSIONS
TECHNICAL SPECIFICATION
ELECTRICAL
FEATURES
VOLTAGE RATING l 8 STANDARD FINISHES
250V a.c. l SWITCH CONTACTS WITH SILVER CONTACTS ON BOTH SURFACES FOR GOOD CONTINUITY
CURRENT RATING l POSITIVE SWITCH ACTION
10A
l ONLY ONE SIZE OF SCREWDRIVER REQUIRED FOR INSTALLATION
TERMINAL CAPACITY
All products l BACKED OUT AND CAPTIVE TERMINAL SCREWS
4 x 1mm²
4 x 1.5mm²
3 x 2.5mm²
2 x 4mm²
1 x 6mm² CONNECTION OF LED INDICATORS
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
Room Switch – Inside Corridor Switch – Outside
“Occupancy Selector” “Bell Push/Indicator”
IP RATING
IP4X
BOX TYPES
Flush Red LED
DIMENSIONS (MM)
86 12 86 9
86
86
Decorative Wiring Devices | 37
CURRENT RATING
10A
FEATURES
TERMINAL CAPACITY
4 x 1.5mm² l 8 STANDARD FINISHES
2 x 2.5mm² l 30 SECOND FIXED TIME DELAY
1 x 4.0mm²
1 x 6.0mm²
EARTH TERMINAL
3 x 2.5mm²
2 x 4.0mm²
WIRING DIAGRAM
1 x 6.0mm²
CONTACT GAP
Micro Gap
PHYSICAL
AMBIENT OPERATING TEMPERATURE
L in
Time
0°C to +35°C
220-240V~ Delay
IP RATING
IP2X
N in Circuit L out
MAX. INSTALLATION ALTITUDE Load
2000 metres
BOX TYPES
Flush Flush (for extra wiring space)
ECHO™ TRANSMITTERS
OPERATING FREQUENCY:
868.3 MHz
FEATURES
IP RATING
l WIRELESS AND BATTERYLESS, USING RF TECHNOLOGY WITH RANGES UP TO 30M IN IDEAL
IP2X CONDITIONS
MAX. INSTALLATION ALTITUDE
l THE TRANSMITTERS ARE QUICK AND EASY TO INSTALL WITH NO NEED FOR CABLING FROM THE
2000 metres SWITCH TO THE LIGHTING CIRCUIT
l SEE THE ECHO RANGE FOR AVAILABLE RECEIVERS
MOUNTING TRANSMITTERS
PATTRESS
MODULE PLATE
9
86
LATCHES
86
FRONTPLATE
TRANSMITTER MODULE
Decorative Wiring Devices | 39
40 | MK DIMENSIONS