i06732791

Battery Disconnect Switch


SMCS - 1411

Illustration 1 g06096076

The battery disconnect switch is located on the left side of the machine on the rear bumper.

Disconnect Switch ON - To activate


the electrical system, remove the
padlock (if installed) from the
battery disconnect switch and turn
the switch lever clockwise. The
battery disconnect switch must be
turned to the ON position before you
start the engine.

Disconnect Switch OFF - To deactivate the


https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/… 1/2
11/5/2019 992K Wheel Loader ZMX00001-UP (MACHINE) POWERED BY C32 Engine(SEBP5775 - 52) - Documentation

electrical system, turn the battery disconnect


switch counterclockwise to the OFF position.
Secure the battery disconnect switch in the
OFF position by installing a padlock through
the holes on the switch lever and the locking
plate.

Note: The machine is designed so that the status of the battery disconnect switch position can be viewed from
the ground level.

The battery disconnect switch and the engine start switch perform different functions. Turn off the battery
disconnect switch in order to disable the entire electrical system. The battery remains connected to the electrical
system when you turn off the engine start switch.

Turn the battery disconnect switch to the OFF position and secure with a padlock when you service the electrical
system or any other machine components.

Also turn the battery disconnect switch to the OFF position and secure with a padlock when the machine will not
be used for an extended period of a month or more. This action will prevent drainage of the battery.

NOTICE
Never move the battery disconnect switch to the OFF position while the
engine is operating. Serious damage to the electrical system could
result.

To ensure that no damage to the engine occurs, verify that the engine is fully operational before cranking the
engine. Do not crank an engine that is not fully operational.

Perform the following procedure in order to check the battery disconnect switch for proper operation:

1. With the battery disconnect switch in the ON position, verify that electrical components in the operator
compartment are functioning. Verify that the hour meter is displaying information. Verify that the engine
will crank.

2. Turn the battery disconnect switch to the OFF position.

3. Verify that the following items are not functioning: electrical components in the operator compartment,
hour meter and engine cranking. If any of the items continue to function with the battery disconnect
switch in the OFF position, consult your Caterpillar dealer.