Sie sind auf Seite 1von 1

PUMP SIZING CALCULATION

CheCalc.com Tag No. P-101


Chemical Engineering Calculations Description COOLING Pum
Date 02-04-18
User Input V GAS CO.,LTD. By Kriengsak R.

Pipe Diameter ‐ ID2


Flowrate 100.0 m³/h Pipe Length      ‐ L2 P2
Density 1000 kg/m³
P1
Viscosity 1.00 cP h2
Vapor Pressure 1.0 bar abs h1

Differential DP 3.69 bar


Pipe Diameter ‐ ID1
Differential Head 37.6 m
Pipe Length      ‐ L1
Hydraulic power 10.23 kw
NPSH available -6.86 m

Suction Condition Discharge Condition


Pressure P1 0.2 bar abs Pressure P2 3.0 bar abs
Static Head h1 2.0 m Static Head h2 6.0 m
Equipment DP 0.00 bar Equipment DP 0.00 bar
Misc DP 0.00 bar Misc DP 0.00 bar

Piping Piping
Length L1 2.0 m Length L2 40.0 m
Pipe Diameter 4 inch Pipe Diameter 4 inch
Sch/ Thick 40 Sch/ Thick 40
Pipe ID ID1 102.26 mm Pipe ID ID2 102.26 mm

Roughness 0.04572 mm Roughness 0.04572 mm

Fittings No. K DP Fittings No. K


Elbows, 90LR 1 0.25 0.014 Elbows, 90LR 3 0.25
Elbows, 45LR 0 0.19 0.000 Elbows, 45LR 0 0.19
Tees, Thru 0 0.62 0.000 Tees, Thru 0 0.62
Tees, Branch 0 1.00 0.000 Tees, Branch 0 1.00
Ball Valves 0.19 Ball Valves 0.19
Butterfly Valves 0.31 Butterfly Valves 1 0.31
Gate Valves 0 0.13 0.000 Gate Valves 0 0.13
Globe Valves 5.00 Globe Valves 5.00
Check Valves 0 1.88 0.000 Check Valves 1.88
Plug Valves 0.31 Plug Valves 0.31
Pipe Entrance 0 0.50 0.000 Pipe Exit 0 1.00
0.014
Velocity 3.38 m/s Velocity 3.38 m/s
Reynold's No. 345705 Reynold's No. 345705
Pipe DP 0.997 bar/100m Pipe DP 0.997 bar/100
Suction Pressure 0.36 bar Discharge Pressure 4.05 bar